Issue Date: 2014-09-22 Page 1 of 28 Report Reference # 1405008-CB-A1 TRF No: IEC60950_1F Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part 1: General requirements Report Reference No .................. : 1405008-CB-A1 Date of issue ................................. : 2014-09-22 Total number of pages .................. : 28 Applicant's name ........................ : Address ......................................... : Kintron Electronics Co Ltd 17F.-3, No.266, Sec. 1, Wenhua 2nd Rd., Linkou., New Taipei, 244 Taiwan Test specification: Standard ...........................................: IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013 Test procedure .............................. : CB Scheme Non-standard test method ............ : N/A Test Report Form No. .....................: IEC60950_1F Test Report Form(s) originator ..... : SGS Fimko Ltd Master TRF .......................................: Dated 2014-02 Copyright © 2014 Worldwide System for Conformity Testing and Certification of Electrotechnical Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. General disclaimer: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report.

Upload: hahuong

Post on 12-Mar-2018

239 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: TEST REPORT IEC 60950-1 Information technology … cert(1).pdfTest Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part

Issue Date: 2014-09-22 Page 1 of 28 Report Reference # 1405008-CB-A1

TRF No: IEC60950_1F

Test Report issued under the responsibility of:

TEST REPORT

IEC 60950-1 Information technology equipment - Safety -

Part 1: General requirements Report Reference No .................. : 1405008-CB-A1 Date of issue ................................. : 2014-09-22 Total number of pages .................. : 28 Applicant's name ........................ : Address ......................................... :

Kintron Electronics Co Ltd 17F.-3, No.266, Sec. 1, Wenhua 2nd Rd., Linkou., New Taipei, 244 Taiwan

Test specification:

Standard ...........................................: IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013

Test procedure .............................. : CB Scheme Non-standard test method ............ : N/A

Test Report Form No. .....................: IEC60950_1F

Test Report Form(s) originator ..... : SGS Fimko Ltd

Master TRF .......................................: Dated 2014-02

Copyright © 2014 Worldwide System for Conformity Testing and Certification of Electrotechnical Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.

If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.

General disclaimer: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report.

Page 2: TEST REPORT IEC 60950-1 Information technology … cert(1).pdfTest Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part

Issue Date: 2014-09-22 Page 2 of 28 Report Reference # 1405008-CB-A1

TRF No: IEC60950_1F

Test item description .................. : Switching Power Supply Trade Mark ................................... :

Manufacturer ................................. : Kintron Electronics Co Ltd

17F.-3, No.266, Sec. 1, Wenhua 2nd Rd., Linkou., New Taipei, 244 Taiwan

Model/Type reference ................... : Redundant Power Supply: MVP-G600VP, MVP-G400VP, MVP-G460VP, MVP-G500VP, MVP-G550VP. Power Supply: EVP-G600P, EVP-G400P, EVP-G460P, EVP-G500P and EVP-G550P Power Module: UVP-G600P, UVP-G400P, UVP-G460P, UVP-G500P, UVP-G550P

Ratings .......................................... : See page 13 for details

Page 3: TEST REPORT IEC 60950-1 Information technology … cert(1).pdfTest Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part

Issue Date: 2014-09-22 Page 3 of 28 Report Reference # 1405008-CB-A1

TRF No: IEC60950_1F

Testing procedure and testing location:

CB Testing Laboratory:

Testing location/ address ........................... : Superior Product Consulting, Inc. 3rd Fl, 10 Alley 6, Lane 235 Pao Chiao Rd, Hsin-Tien, Taipei, Taiwan

Associated CB Testing Laboratory:

Testing location/ address ........................... :

Tested by (name + signature) .......... : Leo Chang

Approved by (name + signature) ..... : Tim Lu

Testing procedure: TMP/CTF Stage

1:

Testing location/ address ........................... :

Tested by (name + signature) .......... :

Approved by (name + signature) ..... :

Testing procedure: WMT/CTF Stage 2:

Testing location/ address ........................... :

Tested by (name + signature) .......... :

Witnessed by (name + signature) .... :

Approved by (name + signature) ..... :

Testing procedure: SMT/CTF Stage 3 or 4:

Testing location/ address ........................... :

Tested by (name + signature) .......... :

Witnessed by (name + signature) . :

Approved by (name + signature) ..... :

Supervised by (name + signature) ... :

Page 4: TEST REPORT IEC 60950-1 Information technology … cert(1).pdfTest Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part

Issue Date: 2014-09-22 Page 4 of 28 Report Reference # 1405008-CB-A1

TRF No: IEC60950_1F

List of Attachments (including a total number of pages in each attachment): National Differences (-- pages) Enclosures (22 pages) Summary Of Testing No test were conducted Summary of Compliance with National Differences: Countries outside the CB Scheme membership may also accept this report. EU Group Differences, EU Special National Conditions National differences to IEC 60950-1:2005 (Second Edition) + Am 1:2009 evaluated. Austria**, Belarus*, Belgium**, Bulgaria**, China*, Czech Republic**, Denmark, Finland, France**, Germany, Greece**, Group, Hungary**, Ireland, Israel, Italy**, Japan*, Korea, Netherlands**, Norway, Poland**, Portugal**, Romania**, Singapore*, Slovakia**, Slovenia**, Spain, Sweden, Switzerland, USA / Canada, Ukraine*, United Kingdom. (*No National Differences Declared, **Only Group Differences) National differences to IEC 60950-1:2005 evaluated. China, Australia, New Zealand National differences to IEC 60950-1:2001 evaluated. Japan The product fulfills the requirements of: IEC 60664-1: 2007 clearance requirements for 5000 m above sea level (Normal barometric pressure 54.0 kPa). The required clearance is multiplied by the altitude correction factor (1.48), as specified in Table A.2. , CSA C22.2 No. 60950-1-07 + A1:2011, EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 +A2:2013, UL 60950-1 2nd Ed. Revised 2011-12-19

Page 5: TEST REPORT IEC 60950-1 Information technology … cert(1).pdfTest Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part

Issue Date: 2014-09-22 Page 5 of 28 Report Reference # 1405008-CB-A1

TRF No: IEC60950_1F

Copy of Marking Plate The artwork below may be only a draft. The use of certification marks on a product must be authorized by

the respective NCBs that own these marks.

Page 6: TEST REPORT IEC 60950-1 Information technology … cert(1).pdfTest Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part

Issue Date: 2014-09-22 Page 6 of 28 Report Reference # 1405008-CB-A1

TRF No: IEC60950_1F

Page 7: TEST REPORT IEC 60950-1 Information technology … cert(1).pdfTest Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part

Issue Date: 2014-09-22 Page 7 of 28 Report Reference # 1405008-CB-A1

TRF No: IEC60950_1F

Test item particulars : Equipment mobility .............................................. : for building-in Connection to the mains ...................................... : pluggable A Operating condition .............................................. : continuous Access location .................................................... : operator accessible Over voltage category (OVC) .............................. : OVC II Mains supply tolerance (%) or absolute mains supply values ................................................................... : +10%, -10% (Manufacturer declared) Tested for IT power systems ............................... : No IT testing, phase-phase voltage (V) ..................... : N/A Class of equipment .............................................. : Class I (earthed) Considered current rating of protective device as part of the building installation (A) .............................. : 20 A Pollution degree (PD) .......................................... : PD 2 IP protection class ............................................... : IP X0

Altitude during operation (m) .................................... : up to 5000 m Altitude of test laboratory (m) .............................. : less than 2000 m Mass of equipment (kg) ....................................... : Max 2.93kg. Possible test case verdicts: - test case does not apply to the test object ........... : N / A - test object does meet the requirement ................. : P(Pass) - test object does not meet the requirement ........... : F(Fail) Testing: Date(s) of receipt of test item .............................. : N / A Date(s) of Performance of tests ........................... : N / A General remarks: "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a point is used as the decimal separator.

Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:

The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided ................................................................ :

Yes Not applicable

When differences exist; they shall be identified in the General product information section.

Name and address of Factory(ies): Kintron Electronics Co Ltd 17F.-3, No.266, Sec. 1, Wenhua 2nd Rd., Linkou., New Taipei, 244 Taiwan

Page 8: TEST REPORT IEC 60950-1 Information technology … cert(1).pdfTest Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part

Issue Date: 2014-09-22 Page 8 of 28 Report Reference # 1405008-CB-A1

TRF No: IEC60950_1F

GENERAL PRODUCT INFORMATION: Report Summary All applicable tests according to the referenced standard(s) have been carried out. - This test report shall be read in conjunction with the original report, number: 1405008-CB issued on 2014-08-27, with CB Certificate No. DK-40743-UL issued on 2014-09-05. - This report has been corrected, due to: 1. Change Report Reference # from 1405008-CB to 1405008-CB-A1. 2. Correction photo ID 3-01 and ID 3-02. Due to photo and dimension drawing does not match. 3. Correct Photo Couplers source manufacturer and type in Table 1.5.1. Due to typo. 4. Correction Enclosure ID 4-01, ID 4-20, ID 4-21, ID 5-01, ID 5-02 and ID 5-03 versions. 5. Correction Enclosure ID 7-01 rating list model name. Due to typo. Product Description The Power Supply is incorporating power supply boards with electronic components housed in metal chassis. All Redundant Power Supply Models are composed of 2 Power Modules maximum. Model Differences Models UVP-G600P, UVP-G400P, UVP-G460P, UVP-G500P, UVP-G550P are Power Modules, which are identical to each other except for output ratings and model designation. Models MVP-G600VP, MVP-G400VP, MVP-G460VP, MVP-G500VP, and MVP-G550VP are Redundant Power Supply, which are similar to each other except for output ratings and model designation. Models EVP-G600P, EVP-G400P, EVP-G460P, EVP-G500P and EVP-G550P are Power Supply, which are similar to each other except for output ratings and model designation. Redundant Power Supply Model MVP-G600VP used one or two Power Module Model UVP-G600P. Redundant Power Supply Model MVP-G400VP used one or two Power Module Model UVP-G400P. Redundant Power Supply Model MVP-G460VP used one or two Power Module Model UVP-G460P. Redundant Power Supply Model MVP-G500VP used one or two Power Module Model UVP-G500P. Redundant Power Supply Model MVP-G550VP used one or two Power Module Model UVP-G550P. Redundant Power Supply Model EVP-G600P used one Power Module Model UVP-G600P. Redundant Power Supply Model EVP-G400P used one Power Module Model UVP-G400P. Redundant Power Supply Model EVP-G460P used one Power Module Model UVP-G460P. Redundant Power Supply Model EVP-G500P used one Power Module Model UVP-G500P. Redundant Power Supply Model EVP-G550P used one Power Module Model UVP-G550P. Additional Information The product was investigated to the following additional standards: EN 60950- 1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 (which includes all European national differences, including those specified in this test report). Licenses for critical components to be furnished by applicant upon request. Technical Considerations

• The product was submitted and evaluated for use at the maximum ambient temperature (Tma)

Page 9: TEST REPORT IEC 60950-1 Information technology … cert(1).pdfTest Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part

Issue Date: 2014-09-22 Page 9 of 28 Report Reference # 1405008-CB-A1

TRF No: IEC60950_1F

permitted by the manufacturer’s specification of: 40 degree C

• The means of connection to the mains supply is: Pluggable A and Detachable power cord

• The product is intended for use on the following power systems: TN

• The equipment disconnect device is considered to be: Appliance inlet

• The following accessible locations (with circuit/schematic designation) are within a limited current circuit: Secondary pin of CY3.

• The product was investigated to the following additional standards: IEC 60664-1: 2007 clearance requirements for 5000 m above sea level (Normal barometric pressure 54.0 kPa). The required clearance is multiplied by the altitude correction factor (1.48), as specified in Table A.2.

Engineering Conditions of Acceptability When installed in an end-product, consideration must be given to the following:

• The end-product Electric Strength Test is to be based upon a maximum working voltage of: Primary-Earthed Dead Metal: 340 Vrms, 608 Vpk, Primary-SELV: 344 Vrms, 640 Vpk

• The following secondary output circuits are SELV: All outputs

• The following secondary output circuits are at hazardous energy levels: +12V output

• The power supply terminals and/or connectors are: Appliance inlet suitable for field wiring, output suitable for factory wiring only.

• The maximum investigated branch circuit rating is: 20 A

• The investigated Pollution Degree is: 2

• Proper bonding to the end-product main protective earthing termination is: Not required

• An investigation of the protective bonding terminals has: Been conducted

• The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2 insulation system with the indicated rating greater than Class A (105°C): T3 and T301 (Class B)

• The following end-product enclosures are required: Fire and Electrical. Appliance Inlet side evaluated for Fire, Electrical and Mechanical Enclosure. All other enclosure sides evaluated for internal enclosure.

• The equipment is suitable for direct connection to: AC mains supply

• The product was investigated to the following additional standards: IEC 60664-1:2007, clearance requirements for 5000 m above sea level. The required clearance is multiplied by the altitude

Page 10: TEST REPORT IEC 60950-1 Information technology … cert(1).pdfTest Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part

Issue Date: 2014-09-22 Page 10 of 28 Report Reference # 1405008-CB-A1

TRF No: IEC60950_1F

correction factor (1.48), as specified in Table A.2.

Abbreviations used in the report: - normal condition ............................................ N.C. - single fault condition ....................................... S.F.C - functional insulation ....................................... OP - basic insulation .............................................. BI - between parts of opposite polarity

BOP - supplementary insulation ............................... SI

- double insulation ............................................ DI - reinforced insulation ...................................... RI Indicate used abbreviations (if any)

Page 11: TEST REPORT IEC 60950-1 Information technology … cert(1).pdfTest Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part

Issue Date: 2014-09-22 Page 11 of 28 Report Reference # 1405008-CB-A1

TRF No: IEC60950_1F

Input and Output rating:

Model Name Input rating

Output rating

+5V +3.3V +12V -12V +5Vsb

+3.3V and +5V Max.

Max. power

MVP-G400VP, EVP-G400P

100-240Vac, 47-63Hz, 9-4A

24A 24A 32A 0.8A 3.5A 160W 400W MVP-G460VP, EVP-G460P 24A 24A 37A 0.8A 3.5A 160W 460W MVP-G500VP, EVP-G500P 25A 25A 41A 0.8A 3.5A 170W 500W MVP-G550VP, EVP-G550P 25A 25A 45A 0.8A 3.5A 170W 550W MVP-G600VP, EVP-G600P 25A 25A 49A 0.8A 3.5A 170W 600W

UVP-G400P -- -- 32A -- 3.5A -- 400W UVP-G460P -- -- 37A -- 3.5A -- 460W UVP-G500P -- -- 41A -- 3.5A -- 500W UVP-G550P -- -- 45A -- 3.5A -- 550W UVP-G600P -- -- 49A -- 3.5A -- 600W

Page 12: TEST REPORT IEC 60950-1 Information technology … cert(1).pdfTest Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part

Issue Date: 2014-09-22 Page 12 of 28 Report Reference # 1405008-CB-A1

IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict

TRF No: IEC60950_1F

1 GENERAL Pass 1.5 Components Pass 1.5.1 General Pass

Comply with IEC 60950-1 or relevant component standard

See critical components for details.

Pass

1.5.2 Evaluation and testing of components Components certified to IEC harmonized standard and checked for correct application. Components, for which no relevant IEC-Standard exists, have been tested under the conditions occurring in the equipment, using applicable parts of IEC 60950-1. Components not certified are used in accordance with their ratings and they comply with applicable parts of IEC 60950-1 and the relevant component Standard.

Pass

1.5.3 Thermal controls N/A 1.5.4 Transformers Transformer used is suitable

for its intended application and complies with the relevant requirements of the standard. See Annex C for details.

Pass

1.5.5 Interconnecting cables No interconnecting cables provided as part of the equipment.

N/A

1.5.6 Capacitors bridging insulation Line-to-line capacitors are subclass X1 or X2. PRI-to-earth capacitors are subclass Y1 or Y2. Double Insulation bridged by a single capacitor complying with IEC 60384-14, subclass Y1. Accessible conductive parts separated from other parts by DOUBLE or REINFORCED INSULATION bridged by CY3 comply with the requirements for LIMITED CURRENT CIRCUITS.

Pass

1.5.7 Resistors bridging insulation See below Pass 1.5.7.1 Resistors bridging functional, basic or

supplementary insulation Only bridging functional insulation.

Pass

Page 13: TEST REPORT IEC 60950-1 Information technology … cert(1).pdfTest Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part

Issue Date: 2014-09-22 Page 13 of 28 Report Reference # 1405008-CB-A1

IEC/EN 60950-1 Clause Requirement + Test Result - Remark Verdict

TRF No: IEC60950_1F

1.5.7.2 Resistors bridging double or reinforced insulation between a.c. mains and other circuits

N/A

1.5.7.3 Resistors bridging double or reinforced insulation between a.c. mains and antenna or coaxial cable

No resistors bridging double or reinforced insulation.

N/A

1.5.8 Components in equipment for IT power systems N/A 1.5.9 Surge suppressors Pass 1.5.9.1 General See critical components. Pass 1.5.9.2 Protection of VDRs A fuse connected in the line

phase and primary circuit with the VDRs.

Pass

1.5.9.3 Bridging of functional insulation by a VDR VDRs provided and connected in primary circuit only.

Pass

1.5.9.4 Bridging of basic insulation by a VDR N/A 1.5.9.5 Bridging of supplementary, double or reinforced

insulation by a VDR N/A