TEST REPORT
REPORT NO. ....…..…….….... : HST200909-1844-CE-E
EQUIPMENT UNDER TEST… : Automatic Voltage Regulator
MODEL NAME ............... .…... :
AVR 500, AVR 600, AVR 700, AVR 750, AVR
800, AVR 850, AVR 1000, AVR 1200, AVR
1500, AVR 1600, AVR 2000
APPLICANT NAME…….. .….. : Guangdong East Power Co., Ltd.
APPLICANT ADDRESS……... :No. 6 Northern Industry Road, Songshan Lake
Sci&Tech Industry Park, Dongguan, P. R. China
CLASSIFICATION……….….. : CE-EMC
PREPARED BY…………. .….. : Guangzhou Huesent Testing Service Co., Ltd.
Report Number: HST200909-1844-CE-E
Page 2 of 41
TABLE OF CONTENT
1 Verification of Conformity ................................................................................................ 4
2 Test Summary................................................................................................................. 5
3 System Description......................................................................................................... 7
4 Product Information ........................................................................................................ 7
5 Test Facility ..................................................................................................................... 7
6 Equipments Used During Test ........................................................................................ 8
7 Emission Test.................................................................................................................. 9
7.1 AC mains port: Conducted Emission 0.15 MHz – 30 MHz........................................ 9
7.1.1. E.U.T. Operation ............................................................................................... 9
7.1.2. Test Setup ........................................................................................................ 9
7.1.3. Measurement Data ......................................................................................... 10
7.1.4. Photograph..................................................................................................... 12
7.2 Radiated Disturbance Test, 30M-1GHz .................................................................. 13
7.2.1. E.U.T. Operation ............................................................................................. 13
7.2.2. Measurement Setup ....................................................................................... 13
7.2.3. Measurement Data ......................................................................................... 14
7.2.4. Photograph..................................................................................................... 18
7.3 Harmonics Emission Test ....................................................................................... 19
7.3.1 E.U.T. Operation ............................................................................................. 19
7.3.2 Measurement Data ......................................................................................... 20
7.1 Flicker Test ............................................................................................................. 21
7.4.1 E.U.T. Operation ............................................................................................. 21
7.4.2 Measurement Data ......................................................................................... 21
7.4.3 Photograph..................................................................................................... 23
8 Immunity Test................................................................................................................ 24
8.1 Performance Criteria Description in EN 61000-6-1................................................. 24
8.2 Electrostatic Discharge Immunity Test (ESD) ......................................................... 25
8.2.1. Block Diagram of Test Setup .......................................................................... 25
8.2.2. Test Procedure ............................................................................................... 26
8.2.3. Test Operation ................................................................................................ 26
8.2.4. Test Results .................................................................................................... 26
8.2.5. Photograph..................................................................................................... 27
8.3 Radio-frequency Electromagnetic Fields Immunity Test(RS) ............................. 28
8.3.1. E.U.T. Operation ............................................................................................. 28
8.3.2. Test Results On Enclosure ports: ................................................................... 28
Report Number: HST200909-1844-CE-E
Page 3 of 41
8.3.3. Photograph..................................................................................................... 29
8.4 Fast Transients Immunity Test (EFT) ...................................................................... 30
8.4.1. E.U.T. Operation ............................................................................................. 30
8.4.2. Test Results On AC Supply:............................................................................ 30
8.4.3. Photograph..................................................................................................... 31
8.5 Surge Immunity Test ( Su ) ..................................................................................... 32
8.5.1. E.U.T. Operation ............................................................................................. 32
8.5.2. Test Results On AC Power ports: ................................................................... 32
8.5.3. Photograph..................................................................................................... 33
8.6 Radio-frequency Common Mode Immunity Test(CS) ......................................... 34
8.6.1. E.U.T. Operation ............................................................................................. 34
8.6.2. Test Results On AC Power ports: ................................................................... 34
8.6.3. Photograph..................................................................................................... 35
8.7 Voltage Dips and Interruptions (VD) ....................................................................... 36
8.7.1. E.U.T. Operation ............................................................................................. 36
8.7.2. Test Results On AC Power ports: ................................................................... 36
8.7.3. Photograph..................................................................................................... 37
9 Appendix I..................................................................................................................... 38
Report Number: HST200909-1844-CE-E
Page 4 of 41
1 Verification of Conformity
Equipment Under Test…… : Automatic Voltage Regulator
Trade Name………………… : EAST
Model Number.................... : See the model number shown on cover page
Serial Number……………... : N/A
Applicant…………………… : Guangdong East Power Co., Ltd.
Address…………………….. : No. 6 Northern Industry Road, Songshan Lake Sci&Tech Industry
Park, Dongguan, P. R. China
Manufacturer………………. : Guangdong East Power Co., Ltd.
Address…………………….. : No. 6 Northern Industry Road, Songshan Lake Sci&Tech Industry
Park, Dongguan, P. R. China
Type of Test………………… : Entrusted testing
Technical Standards……… : EN 61000-6-1: 2007, EN 61000-6-3: 2007
Test Result…………………. : Confirm
File Number………………... : HST200909-1844-CE-E
Date of test…………………. : Sep. 24, 2009 – Oct. 28, 2009
Date of Sample Receive…. : Sep. 24, 2009
Deviation…………………… : None
Condition of Test Sample.. : Normal
Report Number: HST200909-1844-CE-E
Page 5 of 41
2 Test Summary
Test Test Requirement Test Method Class / Severity Result
Enclosure port :
Radiated Disturbance
30 MHz - 1 GHz
EN 61000-6-3: 2007 CISPR 16-2-3 PASS
AC mains port:
Harmonic & Flicker
0 kHz – 2 kHz
IEC 61000-3-2
IEC 61000-3-3
IEC 61000-3-11
IEC 61000-3-12
PASS5
AC mains port:
Conducted Emission
0.15 MHz – 30 MHz
CISPR 16-2-1, 7.4.1
CISPR 16-1-2, 4.3PASS
AC mains port:
Discontinue continuous
disturbance voltage
0.15 MHz – 30 MHz
CISPR 14-1 N/A1
DC power port:
Conducted Emission
0.15 MHz – 30 MHz
CISPR 16-2-1, 7.4.1
CISPR 16-1-2, 4.3
Telecommunications/
network port
Conducted Emission
0,15 MHz - 30 MHz
CISPR 22
Table 1
N/A2
Enclosure port:
Power-frequency
magnetic field (HF)
IEC 61000-4-8 Table 1 N/A3
80M-1000MHz 3V/m r m s
(unmodulated,) 1kHz, 80% AM
PASSEnclosure port:
Radio-frequency
electromagnetic field.
Amplitude modulated
(RS)
EN 61000-6-1: 2007
IEC 61000-4-3 1.4G-2.7GHz 3V/m r m s
(unmodulated,) 1kHz, 80% AM
N/A4
Report Number: HST200909-1844-CE-E
Page 6 of 41
Enclosure port:
Electrostatic Discharge IEC 61000-4-2
Contact: 4 kV Air: 8 kV PASS
Immunity – Signal
ports
IEC 61000-4-6, IEC 61000-4-4
Table 2 N/A2
Immunity – Input and
output DC power ports
IEC 61000-4-6, IEC 61000-4-5, IEC 61000-4-4
Table 3 N/A2
Immunity – Input and
output AC power ports
EN 61000-6-1: 2007
IEC 61000-4-6, IEC 61000-4-11, IEC 61000-4-5, IEC 61000-4-4
Table 4 PASS
Remark:
N/A1: Not applicable, Since the EUT does not belonged to the equipment such as: switching
operations in thermostatically controlled appliances, automatic programme controlled machines
and other electrically controlled or operated appliances generate discontinuous disturbance.
N/A2: Not applicable, since the EUT has no signal/ AC/ DC or telecommunication ports.
N/A3: Not applicable, since the EUT is not an apparatus containing devices susceptible to
magnetic fields.
N/A4: Not applicable, since the highest frequency of the internal sources of the EUT is less than
108 MHz and the measurement shall only be made up to 1 GHz. So the frequency range
above 1GHz need not be selected to cover the frequencies with the highest potential risk of
a disturbance.
Pass5: The applicant stated the impedance of the supply system (Zref) for the EUT should be 50%
of the test impedance Ztest (0.4ohm+j0.3ohm), i.e. the Zref shall be 0.2ohm+j0.15ohm, more
details please refer to clause 7.4 in this report.
Models: AVR 500, AVR 600, AVR 700, AVR 750, AVR 800, AVR 850, AVR 1000, AVR 1200, AVR
1500, AVR 1600, AVR 2000
The max rated power model: AVR 2000 was actually carried through the tests as all the
models were electric/ structure and component/ function identical with difference being
model number/ rated power and appearance.
Report Number: HST200909-1844-CE-E
Page 7 of 41
3 System Description
EUT Test Procedure:
1. Connect the EUT with loading to the mains, then power on the EUT.
2. Make sure EUT work normally in full load mode during the whole EMI tests, and make it
work in half-power mode during the whole EMS tests.
4 Product Information
Housing Type : metallic Power during Test : AC230V, 50Hz
Rated Power :
Model Rated Output Voltage Rated Output Current
AVR 500 1.36A
AVR 600 1.8A
AVR 700 1.9A
AVR 750 2.0A
AVR 800 2.2A
AVR 850 2.3A
AVR 1000 2.7A
AVR 1200 3.2A
AVR 1500 4.1A
AVR 1600 4.35A
AVR 2000
220/230/240VAC
5.45A
5 Test Facility
Huesent Testing Service Ltd. which is located at
No. 91, Dongguanzhuang Road, Tianhe District, Guangzhou City, Guangdong Province,
China
Tel: 86-20-28263298 Fax: 86-20-28263237
All the witness tests were performed in Guangzhou GRG Metrology and Test Technology Ltd.
which is located at
No. 163 Pingyun Road, West of Huangpu Highway, Tianhe District, Guangzhou City, 510656,
Guangdong Province, P. R. China
Tel: 86-20- 38697110 Fax: 86-020-38698685 Email:[email protected]
Report Number: HST200909-1844-CE-E
Page 8 of 41
6 Equipments Used During Test
No. Test item. Name of Equipment’s Model/Type Last Calibrated Date
1 RE EMI Test Receiver R&S ESU 2009-10-23
2 RE/ RS Anechoic Chamber ETS-Lindgren
RFD-F/A-100 2009-4-11
3 RE Antenna ETS-Lindgren 3142C 2009-8-4
4 ESD ESD Gun EMC Partner ESD3000 2009-7-17
5 ESD ESD discharge module EMC Partner
ESD3000DN1 2009-7-17
6 RS Antenna SCHWARZBECK STLP
9128E 2009-8-4
7 RS Isotropic Electric Field Probe Raidcentre 06200036 2008-12-26
8 RS Singal Generator R&S SML03 2009-3-7
9 RS Power Amplifier PRANA R&D
AP32DT214 2009-7-17
10 CE Receiver R&S ESCI 2009-6-25
11 CE LISN SCHWARZBECK
NSLK8128 2009-7-3
12 CE Shielded Room ETS-Lindgren RFD-100 2009-4-10
13 Har/ Flk Harmonic test system California Instruments
PACS-3 2009-7-3
14 EFT EFTgenerator EMC Partner TRA
2000 2009-7-3
15 CS Singal generator R&S SML03 2009-3-7
16 CS CDN Liithi L801 M2/M3 2009-7-3
17 CS Power Amplifier PRANA R&D
AP32DT214 2009-7-17
18 Su SURGE test system EMC Partner TRA2000
SURGE 2009-7-3
19 VD TRA2000 power dips test
system EMC Partner TRA2000 2009-7-3
Note:
/
Report Number: HST200909-1844-CE-E
Page 9 of 41
7 Emission Test
7.1 AC mains port: Conducted Emission 0.15 MHz – 30 MHz
Test Requirement: EN 61000-6-3
Test Method: CISPR 16-2-1, 7.4.1, CISPR 16-1-2, 4.3
Class: Table 1 of EN 61000-6-3
Detector: Peak for pre-scan
Quasi-Peak and Average at frequency with maximum peak (150k-30MHz resolution bandwidth: 9kHz)
Test Date: Oct. 26, 2009
7.1.1. E.U.T. Operation Operating Environment:
Temperature: 25.0 C Humidity:60% RH Atmospheric Pressure:103.0kPa
EUT Operation: 1. Connect the EUT with load to the mains in 230VAC/50Hz. 2. Make sure EUT work normally in full load mode during the whole test.
Test at about 160 kHz was made over a range of 0.9 to 1.1 times the rated voltage in
order to check whether the level of disturbance varies considerably with the supply voltage. Test the EUT in work normally of normal operating status, since no considerably varies
found.
7.1.2. Test Setup
Report Number: HST200909-1844-CE-E
Page 10 of 41
7.1.3. Measurement Data
Pre-scan was performed with peak detected on both live and neutral cable. Quasi-peak & average measurements were performed on the neutral lines at the frequencies at which maximumu peak emission level were detected. Please see the attached Quasi-peak and Average test results.
Live Line
Peak Scan
Quasi-peak and Average measurement
Freq.
(MHz) Line
QP
(dBµV)
QP limit
(dBµV)
Margin
(dB)
AV
(dBµV)
AV limit
(dBµV)
Margin
(dB)
0.154 Live 41.3 65.9 -24.6 27.4 55.9 -28.5
0.5-5 Live <30 56 / <25 46 /
5-30 Live <30 60 / <25 50 /
Report Number: HST200909-1844-CE-E
Page 11 of 41
Neutral Line
Peak Scan
Quasi-peak and Average measurement
Freq.
(MHz) Line
QP
(dBµV)
QP limit
(dBµV)
Margin
(dB)
AV
(dBµV)
AV limit
(dBµV)
Margin
(dB)
0.15-0.5 Neutral <40 66-56 / <25 56-46 /
0.5-5 Neutral <30 56 / <25 46 /
5-30 Neutral <30 60 / <25 50 /
Report Number: HST200909-1844-CE-E
Page 12 of 41
7.1.4. Photograph
Report Number: HST200909-1844-CE-E
Page 13 of 41
7.2 Radiated Disturbance Test, 30M-1GHz
Test Requirement: EN 61000-6-3
Test Method: CISPR 16-2-3
Class: Table 1 of EN 61000-6-3
Frequency Range: 30MHz-1GHz
Detector: Peak for pre-scan
Quasi-Peak at frequency with maximum peak ( 30M-1GHz resolution bandwidth: 120kHz)
Test Date: Oct. 26, 2009
7.2.1. E.U.T. Operation Operating Environment:
Temperature:25.0C Humidity:60% RH Atmospheric Pressure:103.0kPa
EUT Operation: 1. Connect the EUT with load to the mains in 230VAC/50Hz. 2. Make sure EUT work normally in full load mode during the whole test.
7.2.2. Measurement Setup
Example test arrangement for tabletop equipment ( radiated emission measurement )
Report Number: HST200909-1844-CE-E
Page 14 of 41
7.2.3. Measurement Data
Test in 230VAC/50Hz
Horizontal Curve
Peak Scan
Quasi-peak measurement
Frequency Level Transducer
Factor Limit Margin
MHz dBuV/m dB dBuV/m dB
141.72 25.4 8.8 40.0 -14.6
187.97 29.5 11.0 40.0 -10.5
191.97 29.5 11.1 40.0 -10.5
Note: The transducer factor includes antenna factor and cable loss.
Report Number: HST200909-1844-CE-E
Page 15 of 41
Test in 230VAC/50Hz
Vertical Curve
Peak Scan
Quasi-peak measurement
Frequency Level Transducer
Factor Limit Margin
MHz dBuV/m dB dBuV/m dB
136.73 30.6 8.7 40.0 -9.4
188.02 25.2 11.0 40.0 -14.8
Note: The transducer factor includes antenna factor and cable loss.
Report Number: HST200909-1844-CE-E
Page 16 of 41
Test in 120VAC/50Hz
Horizontal Curve
Peak Scan
Quasi-peak measurement
Frequency Level Transducer
Factor Limit Margin
MHz dBuV/m dB dBuV/m dB
120.3 25.7 8.6 40.0 -14.3
230-1000 <40 / 47 /
Note: The transducer factor includes antenna factor and cable loss.
Report Number: HST200909-1844-CE-E
Page 17 of 41
Test in 120VAC/50Hz
Vertical Curve
Peak Scan
Quasi-peak measurement
Frequency Level Transducer
Factor Limit Margin
MHz dBuV/m dB dBuV/m dB
30-230 <30 / 40 /
230-1000 <37 / 47 /
Note: The transducer factor includes antenna factor and cable loss.
Report Number: HST200909-1844-CE-E
Page 18 of 41
7.2.4. Photograph
Report Number: HST200909-1844-CE-E
Page 19 of 41
7.3 Harmonics Emission Test
Test Requirement: EN 61000-6-3
Test Method: IEC 61000-3-2
Frequency Range: 100Hz to 2kHz
Limits: Class A
Measure Time: 3 minutes.
Test Date: Oct. 26, 2009
7.3.1 E.U.T. Operation
Operating Environment:
Temperature(C): 25.0
Humidity(% RH): 60
Atmospheric Pressure (kpa): 103.0
EUT Operation:
1. Connect the EUT with load to the mains in 230VAC/50Hz.
2. Make sure EUT work normally in full load mode during the whole test.
Report Number: HST200909-1844-CE-E
Page 20 of 41
7.3.2 Measurement Data
TestVoltage:232.1V~ Power : 1125.3W Power factor: 1.000 Irms: 4.975A
Hn Ieff [A] Limit [A] Result Hn Ieff [A] Limit [A] Result
1 4.899 PASS 21 0.001 0.1071 PASS
2 0.003 1.0800 PASS 22 0.000 0.0836 PASS
3 0.086 2.3000 PASS 23 0.001 0.0978 PASS
4 0.001 0.4300 PASS 24 0.000 0.0767 PASS
5 0.007 1.1400 PASS 25 0.000 0.0900 PASS
6 0.001 0.3000 PASS 26 0.000 0.0708 PASS
7 0.013 0.7700 PASS 27 0.000 0.0833 PASS
8 0.001 0.2300 PASS 28 0.000 0.0657 PASS
9 0.003 0.4000 PASS 29 0.000 0.0776 PASS
10 0.000 0.18400 PASS 30 0.000 0.0613 PASS
11 0.004 0.3300 PASS 31 0.000 0.0726 PASS
12 0.000 0.1533 PASS 32 0.000 0.0575 PASS
13 0.002 0.2100 PASS 33 0.000 0.0682 PASS
14 0.000 0.1314 PASS 34 0.000 0.0541 PASS
15 0.002 0.1500 PASS 35 0.000 0.0643 PASS
16 0.000 0.1150 PASS 36 0.000 0.0511 PASS
17 0.001 0.1324 PASS 37 0.000 0.0608 PASS
18 0.000 0.1022 PASS 38 0.000 0.0484 PASS
19 0.001 0.1184 PASS 39 0.000 0.0577 PASS
20 0.000 0.0920 PASS 40 0.000 0.0540 PASS
Report Number: HST200909-1844-CE-E
Page 21 of 41
7.4 Flicker Test
Test Requirement: EN61000-6-3
Test Method: IEC 61000-3-3
Limit: Clause 4
Measure Time: 10 minutes
Test Date: Oct. 26, 2009
7.4.1 E.U.T. Operation
Operating Environment:
Temperature(C): 25.0
Humidity(% RH): 60
Atmospheric Pressure (kpa): 103.0
EUT Operation:
1. Connect the EUT with load to the mains in 230VAC/50Hz.
2. Make sure EUT work normally in full load mode during the whole test.
7.4.2 Measurement Data
EUT values
Zref =Ztest Zref =50%Ztest Limit Result
Pst 1.422 0.711 1.00 PASS*
Plt 0.621 0.3105 0.65 PASS*
dc [%] 0.87 0.435 3.30 PASS*
dmax [%] -10.77 -5.385 6.00 PASS*
dt [s] 0.01 0.01 0.50 PASS*
Note:
*: The applicant stated the impedance of the supply system (Zref) for the EUT should be 50% of
the test impedance Ztest (0.4ohm+j0.3ohm), i.e. the Zref shall be 0.2ohm+j0.15ohm
Report Number: HST200909-1844-CE-E
Page 22 of 41
More details about the Zref please refer the EN 61000-3-11 clause 6.1.3 listed as below:
Report Number: HST200909-1844-CE-E
Page 23 of 41
7.4.3 Photograph
Photograph of EUT’s set-up in the harmonic and flick tests is as follows:
Report Number: HST200909-1844-CE-E
Page 24 of 41
8 Immunity Test
8.1 Performance Criteria Description in EN 61000-6-1
Criterion A: The apparatus shall continue to operate as intended during and after the test. No
degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation and what the user may reasonably expect from the apparatus if used as intended.
Criterion B: The apparatus shall continue to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. No change of actual operating state or stored data is allowed. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation and what the user may reasonably expect from the apparatus if used as intended.
Criterion C:
Temporary loss of function is allowed, provided the function is self-recoverable or can be
restored by the operation of the controls.
Report Number: HST200909-1844-CE-E
Page 25 of 41
8.2 Electrostatic Discharge Immunity Test (ESD)
Test Requirement: EN 61000-6-1
Test Method: IEC 61000-4-2
Port: Enclosure
Test Level: ± 2, 4, 8 kV (Air Discharge)
± 2, 4 kV (Contact Discharge)
± 2, 4 kV (Indirect Discharge)
Characteristics of
Test Generator: 150pF/ 330Ω
Criterion require: B
Test Date: Oct. 27, 2009
8.2.1. Block Diagram of Test Setup
(The 470 k ohm resistors are installed per standard requirement)
Report Number: HST200909-1844-CE-E
Page 26 of 41
8.2.2. Test Procedure
The EUT was located 0.1 m minimum from all side of the HCP.
The support units were located 1 m minimum away from the EUT.
EUT worked with resistance load, and make sure EUT worked normally.
Active the communication function if the EUT has such port(s).
As per the requirement of EN 55024; applying direct contact discharge at the sides other
than front of EUT at minimum 50 discharges (25 positive and 25 negative) if applicable,
can’t be applied direct contact discharge side of EUT then the indirect discharge shall be
applied. One of the test points shall be subjected to at least 50 indirect discharge
(contact) to the front edge of horizontal coupling plane.
Other parts of EUT where it is not possible to perform contact discharge then selecting
appropriate points of EUT for air discharge, a minimum of 10 single air discharges shall be
applied.
The application of ESD to the contact of open connectors is not required.
Putting a mark on EUT to show tested points. The following test condition was followed
during the tests.
Note: As per the A2 to IEC 61000-4-2, a bleed resistor cable is connected between the
EUT and HCP during the test.
8.2.3. Test Operation Operating Environment:
Temperature:25.0C Humidity:60% RH Atmospheric Pressure:103.0kPa
EUT Operation: Test the EUT work normally during the test.
8.2.4. Test Results
The electrostatic discharges were applied as follows:
Amount of Discharges Voltage Coupling Result (Pass/Fail)
Contact Discharge
Indirect Discharge HCP (Front)
Indirect Discharge VCP (Left)
Indirect Discharge VCP (Back)
± 2, 4 kV
Indirect Discharge VCP (Right)
Mini 20 /Point
± 2, 4, 8kV Air Discharge
Pass
Report Number: HST200909-1844-CE-E
Page 27 of 41
8.2.5. Photograph
Report Number: HST200909-1844-CE-E
Page 28 of 41
8.3 Radio-frequency Electromagnetic Fields Immunity Test
(RS)
Test Requirement: EN 61000-6-1
Test Method: IEC 61000-4-3
Criterion required: A
Frequency Range: 80MHz to 1000MHz
Test level: 1, 3V/m (r.m.s.) (unmodulated)
Modulation: 80%, 1kHz Amplitude Modulation
Test Date: Oct. 27, 2009
8.3.1. E.U.T. Operation
Operating Environment:
Temperature: 25.0 C Humidity: 60 % RH Atmospheric Pressure: 103.0 kPa
EUT Operation: Test the EUT work normally during the test.
8.3.2. Test Results On Enclosure ports:
Test ports Level (V/m)
Modulation Frequency
Range
Observations
(Performance Criterion)
Enclosure ports 1, 3 1kHz AM, 80% 80M-1000MHz PASS
Report Number: HST200909-1844-CE-E
Page 29 of 41
8.3.3. Photograph
Report Number: HST200909-1844-CE-E
Page 30 of 41
8.4 Fast Transients Immunity Test (EFT)
Test Requirement: EN 61000-6-1
Test Method: IEC 61000-4-4
Criterion required: B
Test Level: 0.5, 1.0kV(peak) on AC
Polarity: Positive & Negative
Repetition Frequency: 5kHz
Burst Duration: 15ms
Waveform Tr / Td: 5/50 ns
Burst Duration: 300ms
Test Duration: 2 minute per level & polarity
Test Date: Oct. 27, 2009
8.4.1. E.U.T. Operation
Operating Environment:
Temperature: 22.0 C Humidity: 55% RH Atmospheric Pressure: 103.0 kPa
EUT Operation: Test the EUT work normally during the test.
8.4.2. Test Results On AC Supply:
Lead under Test Level (kV)
Coupling Direct/Clamp
EUT operating mode
Observations
(Performance Criterion)
Live + Neutral + Earth 0.5, 1.0 Direct Signal input:
1kHz sine Wave PASS
Report Number: HST200909-1844-CE-E
Page 31 of 41
8.4.3. Photograph
Report Number: HST200909-1844-CE-E
Page 32 of 41
8.5 Surge Immunity Test ( Su )
Test Requirement: EN 61000-6-1
Test Method: IEC 61000-4-5
Criterion required: B
Waveform Tr / Td 1.2/50 (8/20) μs
Test level: L-N: ± 0.5, 1kV, L-PE, N-PE: ± 0.5, 1, 2kV
Test Date: Oct. 27, 2009
8.5.1. E.U.T. Operation
Operating Environment:
Temperature: 25.0 C Humidity: 60 % RH Atmospheric Pressure: 103.0 kPa
EUT Operation: Test the EUT work normally during the test.
8.5.2. Test Results On AC Power ports:
Lead under Test Level (kV)
Wave form Tr / Td (μs)
Phase (deg)
OBSERVATIONS
(PERFORMANCE CRITERION)
L-N ± 0.5, 1kV
L-PE
N-PE
± 0.5, 1,
2kV
1.2/50 (8/20) 0, 90, 180, 270 PASS
Report Number: HST200909-1844-CE-E
Page 33 of 41
8.5.3. Photograph
Report Number: HST200909-1844-CE-E
Page 34 of 41
8.6 Radio-frequency Common Mode Immunity Test(CS)
Test Requirement: EN 61000-6-1
Test Method: IEC 61000-4-6
Criterion required: A
Frequency Range: 0.15MHz to 80MHz
Test level: 1, 3V(r.m.s.) (unmodulated)
Modulation: 80%, 1kHz Amplitude Modulation
Source impedance: 150Ω
Test Date: Oct. 27, 2009
8.6.1. E.U.T. Operation
Operating Environment:
Temperature: 22.0 C Humidity: 55 % RH Atmospheric Pressure: 103.0 kPa
EUT Operation: Test the EUT work normally during the test.
8.6.2. Test Results On AC Power ports:
Lead under Test Level
(V) Modulation
Frequency Range
Observations
(Performance Criterion)
AC power ports 1, 3 1kHz AM, 80% 0.15-80MHz PASS
Report Number: HST200909-1844-CE-E
Page 35 of 41
8.6.3. Photograph
Report Number: HST200909-1844-CE-E
Page 36 of 41
8.7 Voltage Dips and Interruptions (VD)
Test Requirement: EN 61000-6-1
Test Method: IEC 61000-4-11
Criterion required: B or C
% residual voltage: 0, 0.5/1; Criterion: B
70, 25; Criterion: C
Test specification in % residual cycle (in periods of the rated frequency)
Interruptions: 0, 250; Criterion: C
Test Date: Oct. 27, 2009
8.7.1. E.U.T. Operation
Operating Environment:
Temperature: 25.0 C Humidity: 60 % RH Atmospheric Pressure: 103.0 kPa
EUT Operation: Test the EUT work normally during the test.
8.7.2. Test Results On AC Power ports:
% residual voltage Cycle Period (deg) OBSERVATIONS
(PERFORMANCE CRITERION)
0 0.5 0, 180 PASS
0 1 / PASS
70 25 / PASS
0 250 / PASS
Report Number: HST200909-1844-CE-E
Page 37 of 41
8.7.3. Photograph
Report Number: HST200909-1844-CE-E
Page 38 of 41
9 Appendix I Photographs of EUT
Photos of the model AVR 2000 are shown as below:
Report Number: HST200909-1844-CE-E
Page 39 of 41
Report Number: HST200909-1844-CE-E
Page 40 of 41
Report Number: HST200909-1844-CE-E
Page 41 of 41
***End of report***