test report 2012-3092-4628-ren · test report 2012-3092-4628-ren date of issue: february 1, 2012...
TRANSCRIPT
Test report 2012-3092-4628-REN Date of issue: February 1, 2012Number of pages: 25
Prepared for: Barix GmbHEntwicklungKarlstrasse 49
Cust. ID: 1959-24998 D-78054 Villingen-Schwenningen
Phone: 07720-807713Fax: 07720-808048E-Mail: [email protected]: Mr. Braun
Equipment under test: Name:Model:Manufacturer:
Annuncicom 50 Barix GmbH
The EUT has beenmodified during com-pliance testing.
Date of tests: 01/09/2012 - 01/20/2012
Test specifications: Emission: EN 55022:2010 (Limit class: B) Immunity: EN 55024:2010
Test summary:
Emission Tested port Limit class Result
Conducted emissions at signal & telecommunication lines150 kHz - 30 MHz
Ethernet B Passed
Radiated emissions - electromagnetic fields 30 MHz - 1000 MHz Enclosure B Passed
Immunity to ... Tested port Test level Crit. Result
Electrostatic discharge (ESD) Enclosure Air: 8 kV A Cont.: 4 kV A
Passed
Electromagnetic fields 80 MHz - 1000 MHz (AM) Enclosure 3 V/m A PassedElectrical fast transients (Burst) loud speaker, ethernet,
line in0.5 kV A Passed
Surge LAN 1 kV A PassedConducted RF disturbances 150 kHz - 80 MHz (AM) See inside test report 3 V A Passed
Testing location: ELMAC GmbHBoschstraße 2D-71149 Bondorf
Phone: ++49(0)7457-9441-0Fax: ++49(0)7457-9441-99WWW: http://www.elmac.de/ E-Mail: [email protected]
Tested by: February 1, 2012 Verified by: February 1, 2012
C. Eisen Date J. Bühne Date
ELMAC GmbH Test report 2012-3092-4628-REN Page 2/25
Content
1. General Summary of the Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cover2. Test specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33. Equipment Under Test (EUT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44. General Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55. Test Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.1. Conducted emissions at signal & telecommunication lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5.2. Radiated emissions - electromagn. fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
ad 5.2. Radiated emissions - electromagn. fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.3. Electrostatic discharge (ESD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.4. Radio-frequency electromagnetic fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.5. Electrical fast transients (Burst) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.6. Surge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5.7. Conducted disturbances, induced by radio-frequency fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
ELMAC GmbH informs the client that testing is done in accordance with the standard procedures stated under paragraph 2. All deviations will be listedseparately. The test results of this report exclusively refer to the specific sample tested under stated test conditions. ELMAC GmbH shall have no liabilityfor any deductions, inferences or generalisations drawn from the test results. This report must only be reproduced in full. Publications or reproductionsin the form of extracts have to be approved in written form by ELMAC GmbH.
ELMAC GmbH Test report 2012-3092-4628-REN Page 3/25
2. Test specifications
Emission
Document No. Title Limit class
EN 55022:2010CISPR 55022:2008, modifiedDIN EN 55022:2012
Information technology equipment - radio disturbance characteristics -Limits and methods of measurement
B
Immunity
Document No. Title Severity level
EN 55024:2010CISPR 24:2010DIN EN 55024:2011
Information technology equipment - Immunity characteristics - Limitsand methods of measurement
emvID: 3747
ELMAC GmbH Test report 2012-3092-4628-REN Page 4/25
3. Equipment Under Test (EUT)
Name Annuncicom
Model 50
S/N -
Manufacturer Barix GmbH
Kind/Type of EUT POE - Intercom device
Day of receipt 01/09/2012
Kind of EUT handling Plug-in During the tests: As table top equipment
Base unit covering the EUT -
Accessories(Part of the EUT)
-
Support equipment(Not part of the EUT)
Ethernetswitch type FS108P Netgear as POE sourceLaptop type Lifebook S7220 Fujitsu-SiemensNF-Generator type exstreamer 100 Barix
Connected cables and lines Name No of wires Length shield
LAN 8 > 3m yesMIC/LineIn 2 > 3m noDigital In 2 > 3m noLine Output 2 > 3m noSpeaker 2 > 3m noRS232 5 < 3m yesHead phone 2 < 3m no
Power supply Other (see remarks) Support equip.: 230 VAC +10% -15%; 50 Hz
Class of protection againstelectrical shock
III (SELV)
Remarks Power supply via support equipment (poe)
EUT Modifications The EUT was modified as following: EUT-ground and earth separated
eutID: 4628
Tested operation modes
Emission Immunity Test criteria
1 kHz stream 1 kHz stream A:Unwanted changes of selected operation mode- interruption of stream
SNR -90dB A:- SNR max. -50dB
Remarks:
ELMAC GmbH Test report 2012-3092-4628-REN Page 5/25
4. General Test Conditions
4.1. Environment conditions
If not stated otherwise in this test report the tests have been carried out under the following environment conditions:
Temperature: 15 ... 35 °CRelative Humidity: 30 ... 60 %Atmospheric pressure: 860 ... 1060 hPa
4.2. Calibration of test equipment
All test equipment having an important influence on the certainty of the test results is incorporated into a system of regular calibration andmaintenance. The calibration system is a part of ELMAC's quality management system.
4.3. Measurement uncertainty
All EMC tests have a measurement uncertainty. The measurement uncertainty is a parameter related to a quantitative testing characterizingthe range of values that with a certain probability still can be assigned to the result. Commonly the measurement uncertainty is given so, thatthe named probability is 95 %.
In this Test Report, the measurement uncertainties are stated at each Emission test.
The measurement uncertainties for Immunity tests are available on request.
4.4. Perfomance criteria
If no other performance criteria specified in the standards listed in section 2. The performance criteria of EN 61326:1997 + A1:1998+A2:2001 section 6.5 are applied.
ELMAC GmbH Test report 2012-3092-4628-REN Page 6/25
5. Test Results
See next pages.
ELMAC GmbH Test report 2012-3092-4628-REN Page 7/25
- 2 0
- 1 5
- 1 0
- 5
0
5
1 0
1 5
2 0
2 5
3 0
3 5
4 0
4 5
5 0
5 5
6 0
1 5 0 k 3 0 0 4 0 0 5 0 0 8 0 0 1 M 2 M 3 M 4 M 5 M 6 8 1 0 M 2 0 M 3 0 M
Peg
el in
dB
µA
F r e q u e n z i n H z
E S C I 3 e iS ig P C L 2 5 E N 5 5 0 2 2 B
E N 5 5 0 2 2 B e i T K P Q P
E N 5 5 0 2 2 B e i T K P A V
E N 5 5 0 2 2 A e i T K P A V
5.1. Conducted emissions at signal & telecommunication lines150 kHz - 30 MHz
euSigID: 453
EUT: Annuncicom Kind of test: Emission50 Basic standard: EN 55022:2010
Operation mode: 1 kHz stream Measurement uncer-tainty:
2.3 dB
Port: Ethernet Environment: Temp. 21 °CHumidity 29 %
Date of test: 01/20/2012 Atm. press. 965 hPaTested by: TB EUT modified: YesMeasured quantity: Interference current
Result: PassedLimit class: BRemarks:
PEAK Detection - Interference current
Test equipment usedName Model Manufacturer S/N INV RemarksCurrent Clamp PCL-25 Fairchild 215 310
EMI TEST RECEIVER ESCI3 R&S 101070 450
ELMAC GmbH Test report 2012-3092-4628-REN Page 8/25
ad 5.1. Conducted emissions at signal & telecommunication lines150 kHz - 30 MHz
- Continuation -euSigID: 453
EUT: Annuncicom50
Operation mode: 1 kHz stream
QUASI-PEAK Detection - Interference current
Frequency(MHz) QuasiPeak(dBµA) Time(ms) Margin - QPK(dB) Limit - QPK(dBµA)
0.158000 1.6 1000.0 38.0 39.60.178000 4.1 1000.0 34.5 38.60.194000 3.3 1000.0 34.6 37.90.202000 -0.3 1000.0 37.8 37.50.222000 3.2 1000.0 33.6 36.70.250000 -2.6 1000.0 38.4 35.80.262000 -1.8 1000.0 37.2 35.40.294000 1.8 1000.0 32.7 34.40.314000 18.9 1000.0 15.0 33.90.342000 0.5 1000.0 32.7 33.20.394000 -2.8 1000.0 34.8 32.00.426000 -4.2 1000.0 35.5 31.30.446000 2.0 1000.0 29.0 30.90.510000 2.7 1000.0 27.3 30.00.518000 -3.3 1000.0 33.3 30.00.598000 16.2 1000.0 13.8 30.00.630000 13.5 1000.0 16.5 30.00.710000 -3.5 1000.0 33.5 30.00.802000 2.2 1000.0 27.8 30.00.870000 -3.6 1000.0 33.6 30.00.942000 5.1 1000.0 24.9 30.01.026000 -2.2 1000.0 32.2 30.01.074000 5.5 1000.0 24.5 30.01.202000 5.4 1000.0 24.6 30.01.254000 8.5 1000.0 21.6 30.01.370000 -1.1 1000.0 31.1 30.01.566000 11.4 1000.0 18.6 30.01.654000 -4.2 1000.0 34.2 30.01.878000 4.8 1000.0 25.2 30.02.014000 7.6 1000.0 22.4 30.02.190000 3.3 1000.0 26.7 30.02.506000 7.9 1000.0 22.1 30.02.642000 8.1 1000.0 21.9 30.02.818000 6.8 1000.0 23.2 30.03.130000 6.3 1000.0 23.7 30.03.442000 5.3 1000.0 24.7 30.03.758000 4.2 1000.0 25.8 30.04.070000 2.3 1000.0 27.7 30.04.382000 1.3 1000.0 28.7 30.05.010000 -1.7 1000.0 31.7 30.05.238000 5.3 1000.0 24.7 30.05.946000 -6.5 1000.0 36.5 30.06.578000 2.2 1000.0 27.8 30.06.702000 7.8 1000.0 22.2 30.07.374000 5.4 1000.0 24.6 30.07.986000 1.2 1000.0 28.8 30.08.766000 -8.7 1000.0 38.7 30.09.938000 -5.2 1000.0 35.2 30.010.730000 -8.1 1000.0 38.1 30.011.586000 -5.9 1000.0 35.9 30.013.482000 4.9 1000.0 25.1 30.014.214000 5.4 1000.0 24.6 30.016.166000 5.0 1000.0 25.0 30.016.230000 6.5 1000.0 23.5 30.018.246000 7.1 1000.0 22.9 30.019.710000 5.9 1000.0 24.1 30.021.662000 4.0 1000.0 26.0 30.023.130000 3.7 1000.0 26.3 30.025.654000 -1.8 1000.0 31.8 30.029.114000 -5.2 1000.0 35.2 30.0
ELMAC GmbH Test report 2012-3092-4628-REN Page 9/25
ad 5.1. Conducted emissions at signal & telecommunication lines150 kHz - 30 MHz
- Continuation -euSigID: 453
EUT: Annuncicom50
Operation mode: 1 kHz stream
AVERAGE Detection - Interference current
Frequency(MHz) CAverage(dBµA) Time(ms) Margin - CAV(dB) Limit - CAV(dBµA)
0.158000 -1.9 1000.0 31.5 29.60.178000 -6.3 1000.0 34.9 28.60.194000 -1.2 1000.0 29.1 27.90.202000 -3.7 1000.0 31.2 27.50.222000 1.1 1000.0 25.7 26.70.250000 -5.8 1000.0 31.6 25.80.262000 -5.5 1000.0 30.9 25.40.294000 -2.8 1000.0 27.2 24.40.314000 17.9 1000.0 6.0 23.90.342000 -3.7 1000.0 26.8 23.20.394000 -7.0 1000.0 28.9 22.00.426000 -7.7 1000.0 29.1 21.30.446000 -2.6 1000.0 23.6 20.90.510000 -3.2 1000.0 23.2 20.00.518000 -7.0 1000.0 27.0 20.00.598000 11.5 1000.0 8.5 20.00.630000 10.8 1000.0 9.2 20.00.710000 -8.1 1000.0 28.1 20.00.802000 -4.4 1000.0 24.4 20.00.870000 -7.9 1000.0 27.9 20.00.942000 3.6 1000.0 16.4 20.01.026000 -7.4 1000.0 27.4 20.01.074000 -9.3 1000.0 29.3 20.01.202000 0.3 1000.0 19.7 20.01.254000 6.4 1000.0 13.6 20.01.370000 -6.4 1000.0 26.4 20.01.566000 9.4 1000.0 10.6 20.01.654000 -6.0 1000.0 26.0 20.01.878000 2.6 1000.0 17.4 20.02.014000 1.9 1000.0 18.1 20.02.190000 0.4 1000.0 19.6 20.02.506000 4.7 1000.0 15.3 20.02.642000 2.5 1000.0 17.5 20.02.818000 3.1 1000.0 16.9 20.03.130000 1.8 1000.0 18.2 20.03.442000 -0.1 1000.0 20.1 20.03.758000 -0.7 1000.0 20.7 20.04.070000 -2.9 1000.0 22.9 20.04.382000 -3.9 1000.0 23.9 20.05.010000 -6.8 1000.0 26.8 20.05.238000 0.8 1000.0 19.2 20.05.946000 -5.6 1000.0 25.6 20.06.578000 -2.5 1000.0 22.5 20.06.702000 3.6 1000.0 16.4 20.07.374000 1.1 1000.0 18.9 20.07.986000 -3.5 1000.0 23.5 20.08.766000 -13.3 1000.0 33.3 20.09.938000 -10.1 1000.0 30.1 20.010.730000 -12.5 1000.0 32.5 20.011.586000 -10.8 1000.0 30.8 20.013.482000 0.4 1000.0 19.6 20.014.214000 0.5 1000.0 19.5 20.016.166000 0.5 1000.0 19.5 20.016.230000 1.7 1000.0 18.3 20.018.246000 2.5 1000.0 17.5 20.019.710000 2.1 1000.0 17.9 20.021.662000 -6.6 1000.0 26.6 20.023.130000 -0.9 1000.0 20.9 20.025.654000 -8.3 1000.0 28.3 20.029.114000 -9.6 1000.0 29.6 20.0
ELMAC GmbH Test report 2012-3092-4628-REN Page 10/25
ad 5.1. Conducted emissions at signal & telecommunication lines150 kHz - 30 MHz
euSigID: 453
EUT: Annuncicom50
EuSig-1.jpg
ELMAC GmbH Test report 2012-3092-4628-REN Page 11/25
0 10 20 30 40 50 60 70 80
30M 50 60 80 100M 200 300 400 500 800 1G
Pege
l in dB
µV/m
Frequenz in Hz
ESPI7 ee CBL EN55022 A_B 3m
EN 55022 ee Klasse A 3 m QP
EN 55022 ee Klasse B 3 m QP
5.2. Radiated emissions - electromagn. fields30 MHz - 1000 MHz
eeID: 4842
EUT: Annuncicom Kind of test: Emission50 Generic standard: EN 55022:2010
Operation mode: 1 kHz stream Measurement uncer-tainty:
4.5 dB
Port: Enclosure Environment: Temp. 21 °CHumidity 29 %
Date of test: 01/09/2012 Atm. press. 965 hPaTested by: CEPrescan: DoneFinal test: RenouncedTest site (final): Fully Anechoic Chamber EUT modified: NoAntenna distance: 3 m
Result: PassedLimit class: BRemarks:
QUASI-PEAK Detection
During the prescan there were not found any or only very low signals emitted by the EUT. Therefore the test of radiated emissions wasdone without using the Open Area Test Site (OATS). The limit margin is at least 10 dB.
Test equipment usedName Model Manufacturer S/N INV RemarksBiLog Antenna CBL6140A Schaffner 1118 219EMI TEST RECEIVER ESPI7 R&S 100090 359
ELMAC GmbH Test report 2012-3092-4628-REN Page 12/25
ad 5.2. Radiated emissions - electromagn. fields30 MHz - 1000 MHz
eeID: 4842
EUT: Annuncicom Kind of test: Emission50 Generic standard: EN 55022:2010
QUASI-PEAK Detection
Frequency(MHz) QuasiPeak(dBµV/m) Polarisation Margin - QPK(dB) Limit - QPK(dBµV/m)
148.120000 21.4 H 18.6 40.0159.720000 23.2 H 16.8 40.0192.040000 26.3 H 13.7 40.0250.080000 23.6 H 23.4 47.0375.040000 36.3 H 10.7 47.0503.800000 30.6 H 16.4 47.0625.160000 33.2 H 13.8 47.0750.000000 36.1 H 10.9 47.0875.000000 33.8 H 13.2 47.0999.960000 38.5 H 8.5 47.0
ELMAC GmbH Test report 2012-3092-4628-REN Page 13/25
5.3. Electrostatic discharge (ESD)
idID: 2480
EUT: Annuncicom Kind of test: Immunity50 Basic standard: EN 61000-4-2:2009
Operation mode: 1 kHz streamTested Port: Enclosure Environment: Temp. 22 °C
Humidity 30 %Date of test: 01/09/2012 Atm. press. 965 hPaTested by: CE EUT modified: NoRequired perfor-mance criterion
BResult: Passed
Remarks:
Kin
d of
dis
char
ge
Kin
d of
cou
plin
g
Don
e
Test points of EUT
Max
. tes
t vol
tage
(kV
)
Pas
sed
Per
form
ance
crit
erio
n
Remarks
Air Direct U all contactable non-condutive housing surfaces 8 A
Contact Direct U all contactable condutive housing surfaces 4 A
Indirect U HKP: U VKP: U 4 A
Notes:
HKP = Horizontal coupling plateVKP = Vertical coupling plate
At each test voltage at least 10 positive test pulses with a time interval of 1 s and 10 negative test pulses with a time interval of 1 swere carried out.
Test equipment usedName Model Manufacturer S/N INV RemarksESD Generator NSG 435 Schaffner 222 182
ELMAC GmbH Test report 2012-3092-4628-REN Page 14/25
ad 5.3. Electrostatic discharge (ESD)
idID: 2480
EUT: Annuncicom50
Air discharge • Contact discharge
Id-1.jpg
ELMAC GmbH Test report 2012-3092-4628-REN Page 15/25
5.4. Radio-frequency electromagnetic fields80 MHz - 1000 MHz
ifID: 4081
EUT: Annuncicom Kind of test: Immunity50 Basic standard: EN 61000-4-
3:2006+A1:2008+A2:2010Operation mode: SNR -90dBPort: Enclosure Environment: Temp. 22 °CTest site: Fully Anechoic Chamber Humidity 30 %Date of test: 01/09/2012 Atm. press. 965 hPaTested by: CE EUT modified: NoRequired perfor-mance criterion:
AResult: Passed
Remarks:
Test parameters Settings
Amplitude-modulated Field Puls-modulated Field
Frequency range 80 MHz - 1000 MHz
Frequency stepDwell time
1 %1 s
Modulation 1 kHz/AM 80%
Test level (field strength) 3 V/m
Polarization horizontal + vertical
Distance transmitting antenna - EUT 3 m (> 1GHz 1m)
Tested sides of the EUT front, rear
Result
Passed Performance criterion A
Remarks front side: -51,7dB horizontalback side: -62 dB vertical
Test equipment usedName Model Manufacturer S/N INV RemarksSignal Generator SML03 R&S 100935 353
Power Amplifier 100W1000M1 Ampl. Res. 12812 45Power Amplifier 5101F OPHIR 1006 "N/C" 296
BiLog Antenna CBL6140A Schaffner 1118 219Double Ridged Guide Antenna 3115 EMCO 9607-4883 156
ELMAC GmbH Test report 2012-3092-4628-REN Page 16/25
ad 5.4. Radio-frequency electromagnetic fields80 MHz - 1000 MHz
ifID: 4081
EUT: Annuncicom50
If-1.jpg
ELMAC GmbH Test report 2012-3092-4628-REN Page 17/25
ad 5.4. Radio-frequency electromagnetic fields80 MHz - 1000 MHz
ifID: 4081
EUT: Annuncicom50
If-2.jpg
ELMAC GmbH Test report 2012-3092-4628-REN Page 18/25
5.5. Electrical fast transients (Burst)
ibID: 2503
EUT: Annuncicom Kind of test: Immunity50 Basic standard: EN 61000-4-4:2004
Operation mode: 1 kHz streamEnvironment: Temp. 22 °C
Humidity 30 %Date of test: 01/09/2012 Atm. press. 965 hPaTested by: CE EUT modified: NoRequired perfor-mance criterion:
BResult: Passed
Remarks:
Coupling devicesand
Kind of coupling Tested cables/lines
Test
vol
tage
(kV
)
Pas
sed
Per
form
ance
crit
erio
nRemarks
Coupling devicenetwork(in each case un-symmetrically andasymmetrically)
Capacitivecoupling clamp(asymmetrically)
loud speaker, ethernet, line in 0.5 A
Notes:
Tested polarization: Positive + Negative (at each kind of coupling)Duration of test: 60 s at each polarity and kind of couplingTest puls: 5/50 ns; Zi = 50 OhmRepetition frequency: 5 kHz; at test level $ 4 kV: 2.5 kHz
Test equipment usedName Model Manufacturer S/N INV RemarksBurst Generator NSG 2025 Schaffner 1188 237Capacitive Coupling Clamp CDN 125 Schaffner 647 239
ELMAC GmbH Test report 2012-3092-4628-REN Page 19/25
ad 5.5. Electrical fast transients (Burst)
ibID: 2503
EUT: Annuncicom50
Ib-1.jpg
ELMAC GmbH Test report 2012-3092-4628-REN Page 20/25
5.6. Surge
isID: 2261
EUT: Annuncicom Kind of test: Immunity50 Basic standard: EN 61000-4-5:2006
Operation mode: 1 kHz streamEnvironment: Temp. 21 °C
Humidity 29 %Date of test: 01/20/2012 Atm. press. 965 hPaTested by: TB EUT modified: NoRequired perfor-mance criterion:
BResult: Passed
Remarks:
Tested port Lines
Kin
d of
cou
plin
g
Couplingimpedance M
ax. t
est v
olta
ge (k
V)
Pas
sed
Per
form
ance
crit
erio
n
Remarks
LAN shield u 18 µF 1 A
Notes:
Kind of coupling: s = symmetricallyu = unsymmetrically
Test puls: 1.2/50µs; Zi = 2 OhmPolarity: positive and negative at each test voltageNumber of test pulses: $ 6 at each test voltageTime interval between pulses: $10 sTested voltage steps: 0,5 / 1 kV, if max. test voltage = 1 kV
0,5 / 1 / 1,5 / 2 kV, if max. test voltage = 2 kV1 / 2 / 3 / 4 kV, if max. test voltage = 4 kV
Tested phase angels (at AC): 90°/180°/270°
Test equipment usedName Model Manufacturer S/N INV RemarksKombigenerator NSG 3040 TESEQ 097 446
ELMAC GmbH Test report 2012-3092-4628-REN Page 21/25
ad 5.6. Surge
isID: 2261
EUT: Annuncicom50
Is-1.jpg
ELMAC GmbH Test report 2012-3092-4628-REN Page 22/25
5.7. Conducted disturbances, induced by radio-frequency fields150 kHz - 80 MHz
icsID: 2626
EUT: Annuncicom Kind of test: Immunity50 Basic standard: EN 61000-4-6:2009
Operation mode: SNR -90dBEnvironment: Temp. 22 °C
Humidity 30 %Date of test: 01/09/2012 Atm. press. 965 hPaTested by: CE EUT modified: NoRequired perfor-mance criterion:
AResult: Passed
Remarks:
Test parameter Settings
Frequency range 150 kHz - 80 MHz
Frequency stepDwell time
1 %1 s
Modulation 1 kHz/AM 80%
Test voltage 3 V
Tested cables/lines Cable/line/port of the EUT Coupling device used
loudspeaker out, line out, dig in CDN 725 INV 280
mic. in CDN 725 INV 218
ethernet CDN 801 S INV 198
Result
Passed Performance criterion A
Remarks -62 dB at 38MHz ethernet
Test equipment usedName Model Manufacturer S/N INV RemarksRF Generator NSG 2070-1 Schaffner 135 222
EM Injection Clamp CDN 725 Schaffner 146 280EM Injection Clamp CDN 725 Schaffner 133 218Coupling Network CDN 801 S ELMAC 198
ELMAC GmbH Test report 2012-3092-4628-REN Page 23/25
ad 5.7. Conducted disturbances, induced by radio-frequency fields150 kHz - 80 MHz
icsID: 2626
EUT: Annuncicom50
Ics-1.jpg
ELMAC GmbH Test report 2012-3092-4628-REN Page 24/25
ad 5.7. Conducted disturbances, induced by radio-frequency fields150 kHz - 80 MHz
icsID: 2626
EUT: Annuncicom50
Ics-2.jpg
ELMAC GmbH Test report 2012-3092-4628-REN Page 25/25
ad 5.7. Conducted disturbances, induced by radio-frequency fields150 kHz - 80 MHz
icsID: 2626
EUT: Annuncicom50
Ics-3.jpg