Terminology
• Piggyback: general term meaning ‘attach 1 tubing to another’
• Continuous vs Intermittent• Secondary Tubing• Y-site• Volume Controlled set
1
Advantages IV route
•Direct (and instant) access to circulatory system
•Able to give drugs too irritating for gastric mucosa – or for delivering high concentrations
•Since IVPB (“intermittent”) usually over 30 – 60 min, can instantly d/c if reaction occurs
•Able to give meds when GI tract not available
2
Disadvantages of IV route
• Drug interactions because of incompatibilities
• Sometimes drug absorbed by plastic container – full dose not delivered
• Speed shock• Tissue injury – chemical phlebitis or
when certain drugs infiltrate
3
Before hanging med:
• Check expiration date on secondary tubing.
• Does tubing have sterile cap?• 5 rights, plus
– rate of administration– compatibility of IV solution
• clean access (Y-site) ports with alcohol prior to each access.
4
Compatibility & Rate of Administration
Drug books• Davis’s Drug Guide: each drug divided into
sections; find “IV Administration” section– “intermittent administration” &
compatibility• Gahart: information under Dilution, Rate
of Administration, Compatibility– Intermittent IV (vs IV injection or
infusion)
• Pharmacy 5
Ondansetron HCL (Zofran)(Gahart & Nazareno, Intravenous Medications)
Dilution• IV injection:…• Intermittent infusion: single dose should be
diluted in 50 mL of NS or D5W. Also available…
Compatibility• Additive• Y-site
Rate of Administration• IV injection…• Intermittent infusion: single dose over 15 min.
6
Primary IV on Infuser pump
• Y-site above the pump (‘rate controller’)
• Backprime• “piggyback” or “secondary”
function key• Rate• VTBI
7
Primary IV to gravity
Dial-a-flow or stat-master = the ‘rate controller’
• Y-site above rate controller• Set at desired ml/hr AND check gtts/min to
verify accuracy.
Maintenance solution stops while infusing an intermittent med attached above the pump or dial-a flow
8
After hanging med
• Make sure it is infusing– Have you opened the clamp?
• Check on pt after 5-10 min• 6th right: document
9
Syringe Pump
• “spaghetti” tubing• Note where flange of syringe goes• Attach closest to IV insertion site (below
the ‘rate controller’)• Maintenance solution does not stop
10
Saline Lock
• Saline
• Administer med
• Saline
• Used with Syringe pump, gravity tubing, or EID
What if solution is incompatible?
• Use Primary tubing and connect to lower Y-site– Turn off primary IV– Flush with saline before and after
or• Disconnect primary IV, hang NS
and use secondary tubing.
12