Page 1: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical
Page 2: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical
Page 3: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

The Company Terasteel has been present on the construction market since 1994. As of 2007, the company was reorganized and turned itself from a building materials trader into a producer focused on technology and innovation. In 2013 the company opened a new manufacturing center “Metal Service” in order to support customers and to offer a more comprehensive range of complete solutions. This center specializes in galvanized profiles production. The company is part of the Teraplast Group, alongside with Teraplast and Politub companies. Teraplast Group is a supplier of complete systems for construction and installations.

Our products:Terasteel manufactures: Thermal insulating roof and wall panels systems Galvanized profiles type Z, C, U and Sigma Reinforcements for PVC profiles

Applications of thermal insulating panels and galvanised profiles: Storage halls Production halls Halls for a wide variety of services (car-service, car-wash, small workshops ) Refrigerating enclosures Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical industry)

Products complianceFollowing the requirements of applicable regulations, the compliance of sandwich panels and galvanised profiles has been certified for CE marking.

Page 4: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

4

TABLE OF CONTENTS

Thermal-insulating wall panels Mycro-profiling types of metal surfaces Visible joint thermal-insulating wall panel Hidden joint thermal-insulating wall panel Thermal-insulating wall panel for refrigerating enclosures

Thermal-insulating roof panels 3 ribs thermal-insulating roof panel 5 ribs thermal-insulating roof panel

Special applications panels Thermal-insulating roof panel type IsoAgro Thermal-insulating roof panel type IsoBit Thermal-insulating wall and roof panel type IsoSano

Galvanized profiles Z, C, U and Ʃ

Wall and roof covering elements made of profiled steel sheet Structural trays Sinus profiles Trapezoidal profiles Self-supporting sheets

Closing accessories Metal accessories Self-drilling screws Skylights Smoke evacuation traps Sanitary profiles Industrial doors Sealing tapes

Classifications Kits for „ Turnkey” Halls

........................................................................ 5 ................................................ 6

............................................ 7........................................... 8

................... 9

........................................................................ 10....................................... 11....................................... 12

.............................................................................. 13.......................................... 13

............................................. 14........................... 15

...................................................................... 17

....................... 18...................................................................................... 18

......................................................................................... 18 ............................................................................... 18

........................................................................... 19

.......................................................................................... 20.................................................................................. 20................................................................................. 21

................................................................................................. 22 ......................................................................... 22

...................................................................................... 23....................................................................................... 23

.......................................................................................... 23

................................................................................................... 24

................................................................................... 25

Page 5: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

5

The thermal insulating wall panel IsoPer N represents a practical and economical solution, having a visible joint. This type of panel can be assembled horizontally, as well as vertically.

The thermal insulating wall panel IsoPerA represents a constructive solution based on a hidden fixing system, for satisfying the most exigent aesthetic requirements. These panels allow setting up high value decorative walls. They may be assembled horizontally, as well as vertically.

Hidden joint thermal insulating wall panel with polyurethane foam core PUR or fireproof PIR (+ RF)

IsoFrig system provides a great solution for building refrigerating enclosures/storehouses and processing areas. The "FRIGO" joint offers extra thermal insulation.

Thermal insulating wall panel for refrigerating enclosures with polyurethane foam core PUR or fireproof PIR (+ RF)

NOTE: It is highly recommended to avoid using the panels for rooms where alkali substances such as hydrate of sodium shall be used, in concentration higher than 3%.

Visible joint thermal insulating wall panel with polyurethane foam core PUR or fireproof PIR (+ RF)

THERMAL-INSULATING WALL PANELS

Thermal-insulating panels

IsoSano panel represents a solution for achieving closings for strict hygiene applications

Thermal insulating wall panel with polyurethane foam core PUR

Page 6: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

6

STANDARD PLISSE LIS

Combination of micro-profile types: standard - standard; standard - plisse; standard - lis; lis - plisse; lis - lis

STANDARD PLISSE LIS

Combination of micro-profile types: standard - standard; standard - plisse; standard - lis; lis - plisse; lis - lis

STANDARD LIS

Combination of micro-profile types:standard - standard; standard - lis; lis - lis

TYPES OF MICRO-PROFILES OF METAL SURFACES

Page 7: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

7

2

1

3

42

1

3

Pre-painted galvanized steel sheet, according to EN 10143, EN 10346 and EN 10169 current editions. Micro-profiles: STANDARD, PLISSE, LIS

Core: Polyurethane foam PUR or PIR (not harmful).

Sealing gasket: provides good thermal insulation and the joints’ tightness. Panels of thicknesses D=30 and 40 mm are delivered with no sealing gasket. On request, the 40mm panel can be delivered with sealing gasket.

Self- drilling screw with pulley and EPDM gasket.

STANDARD

PLISSE

LIS

Permissible loads:

U* - thermal transfer coefficient. U1 - thermal transfer coefficient, considering the profile's geometry of the panel and the thermal influence of the joint.U2 - thermal transfer coefficient, considering the profile's geometry of the panel. *Calculation according to EN 14509:2013, Method (A.10))

The standard length of the panel is 2 – 13.5 m. Longer panels (of maximum 15m length) and shorter than 2m can be

WIDTH THICKNESS (D) = 100 mm

THICKNESS (D) > 100 mm

± 2 mm± 2 mm

± 2%

manufactured provided the technical department has been consulted.

VISIBLE JOINT THERMAL INSULATING WALL PANEL

Standard colors:

RAL 9002

RAL 9006

RAL 5010

RAL 3011

RAL 6005

RAL 9010

ON REQUEST

Note: The company reserves its right to change the standard colors range, without any prior notification!

RAL 7016

LENGHT ≤ 3000 mmLENGHT > 3000 mm

Deflection to squareness

± 5 mm± 10 mm

6 mm

Thermal-insulating panels

Computing values, wind load under pressure [kN/m2]Weight

Permissible distance between supports [m]

4

Page 8: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

8

U* - thermal transfer coefficient. U1 - thermal transfer coefficient, considering the profile's geometry of the panel and the thermal influence of the joint.U2 - thermal transfer coefficient, considering the profile's geometry of the panel. *Calculation according to EN 14509:2013, Method (A.10)For hidden joints wall panel, the ends of the fixing elements are concealed, and expansion gaps are provided on the horizontally assembled sections.The standard length of the panel is 2 – 13.5 m. Longer panels (of maximum 15m length) and shorter than 2m can be manufactured provided the technical department has been consulted.

2

1

34 2

3

4

1 Pre-painted galvanized steel sheet,according to EN 10143, EN 10346 and EN 10169 current editions. Micro-profiles: STANDARD, PLISSE, LIS

Core: Polyurethane foam PUR or PIR (not harmful).

Sealing gasket: provides good thermalinsulation and the joints’ tightness. The 40 mm thickness panels are delivered with no sealing gasket.

Self-drilling screw with pulley andEPDM gasket.

Recommended for commercial and industrial buildings, where aesthetics makes the difference.

STANDARD

PLISSE

LIS

Permissible loads:

HIDDEN JOINT THERMAL INSULATING WALL PANEL

Dimensional tolerances, under EN 14509:2013

Standard colors:

Note: The company reserves its right to change the standard colors range, without any prior notification!

RAL 9002

RAL 9006

RAL 5010

RAL 3011

RAL 3000

RAL 9007

RAL 6005

RAL 7016

WIDTH THICKNESS (D) = 100 mm

± 2 mm± 2 mm

LENGHT ≤ 3000 mmLENGHT > 3000 mm

Deflection to squareness

± 5 mm± 10 mm

6 mm

ON REQUEST

Computing values, wind load under pressure [kN/m2]Weight

Permissible distance between supports [m]

THICKNESS (D) > 100 mm ± 2 %

40 8.64 0.58 0.50 3.85 2.95 2.41 1.81 1.61 1.32 1.11 4.17 2.95 2.41 1.81 1.61 1.32 1.11

50 9.03 0.46 0.41 4.62 3.29 2.69 2.29 2.04 1.67 1.41 4.65 3.29 2.69 2.29 2.04 1.67 1.41

60 9.42 0.37 0.35 5.05 3.57 2.92 2.53 2.38 2.02 1.71 5.05 3.57 2.92 2.53 2.38 2.02 1.71

80 10.13 0.28 0.26 5.38 3.81 3.11 2.69 2.54 2.3 2.11 5.38 3.81 3.11 2.69 2.54 2.3 2.11

100 10.91 0.22 0.21 5.77 4.08 3.33 2.89 2.72 2.46 2.27 5.77 4.08 3.33 2.89 2.72 2.46 2.27

120 11.72 0.19 0.18 6.26 4.42 3.61 3.13 2.95 2.67 2.46 6.26 4.42 3.61 3.13 2.95 2.67 2.46

Page 9: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

9

2

1

32

1

3

IsoFrig panels are designed for applications in negative temperatures (-40ºC and 0ºC). Applications: Refrigerating enclosures and FRIGO stores, food processing industry, strict hygiene applications.

Pre-painted galvanized steel sheet, according to EN 10143, EN 10346 and EN 10169 current editions, having the following coatings: polyester paint, PVC food foil, PVDF .Micro-profiles: STANDARD, LIS

Core: Polyurethane foam PUR or PIR (not harmful).

3. Pre-painted galvanized steel sheet having the following coatings: polyester paint, PVC food foil, PVDF.

Permissible loads:

U* - thermal transfer coefficient. U1 - thermal transfer coefficient, considering the profile's geometry of the panel and the thermal influence of the joint.U2 - thermal transfer coefficient, considering the profile's geometry of the panel. *Calculation according to EN 14509:2013, Method (A.10)

This wall and ceiling system provides the following benefits: high thermal resistance, mechanical resistance, water-proof, durability, quick and easy assembly.

The standard length of the panel is 2 – 13.5 m. Longer panels (of maximum 15m length) and shorter than 2m can be manufactured provided the technical department has been consulted.

STANDARD

LIS

THERMAL INSULATING WALL PANEL FOR REFRIGERATING ENCLOSURES

Standard colors:

RAL 9002

RAL 9010

Dimensional tolerances, under EN 14509:2013

Thermal-insulating panels

WIDTH THICKNESS (D) > 100 mm

± 2 mm± 2%

LENGHT ≤ 3000 mmLENGHT > 3000 mm

Deflection to squareness

± 5 mm± 10 mm

6 mm

Computing values, wind load under pressure [kN/m2]Weight

Permissible distance between supports [m]120 11.48 0.19 0.18 6.26 4.42 3.61 3.13 2.95 2.67 2.46 6.26 4.42 3.61 3.13 2.95 2.67 2.46

150 12.5 0.15 0.14 6.97 4.93 4.02 3.49 3.29 2.97 2.74 6.97 4.93 4.02 3.49 3.29 2.97 2.74

200 14.4 0.11 0.11 8.08 5.71 4.66 4.04 3.81 3.45 3.17 8.08 5.71 4.66 4.04 3.81 3.45 3.17

Page 10: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

NOTE: It is highly recommended to avoid using the panels for rooms where alkali substances such as hydrate of sodium shall be used, in concentration higher than 3%.

IsoAc3 - is a roof panel having 3 ribs for stiffness, which can be used in every construction application, where the roof’s slope is higher than 7%. The 3 ribs are placed on a 1m width, satisfying thus the standard requirements for resistance, thermal insulation and aesthetics. It represents a practical and economical solution.

3 ribs thermal insulating roof panel with polyurethane foam core PUR or fireproof PIR (+ RF)

IsoAc5 - is a roof panel having 5 ribs for stiffness, designed for construction applications with high requirements of resistance, where the roof’s slope is higher than 7%. The 5 ribs are placed on a 1m width, satisfying thus the higher requirements for resistance and thermal insulation.

3 ribs thermal insulating roof panel with polyurethane foam core PUR or fireproof PIR (+ RF)

IsoBit5 - is a panel designed for roofs that are going to be insulated later on, with bituminized or other kind of membranes (eg. PVC membrane) . This type of panel is assembled by positioning the metal face on the structure.

5 ribs thermal insulating roof panel with one bituminized card face, and a pre-painted steel one, polyurethane foam PUR core

IsoAgro panel is recommended for roofing the agrozootechnical buildings. Roof slope : minimum 7%

IsoSano panel represents an alternative for roofing the agrozootechnical buildings. Roof slope : minimum 7%

Thermal insulating roof panel, having 3 or 5 ribs, one fiberglass face and one pre-painted metal face, polyurethane foam PUR core.

Thermal insulating roof panel, having 3 or 5 ribs, interior PVC foil steel shet and the exterior pre-painted metal face polyurethane foam PUR core.

10

THERMAL-INSULATING ROOF PANELS

Page 11: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

Permissible loads:

U* - thermal transfer coefficient. U1 - thermal transfer coefficient, considering the profile's geometry of the panel and the thermal influence of the joint.U2 - thermal transfer coefficient, considering the profile's geometry of the panel. *Calculation according to EN 14509:2013, Method (A.10)

The standard length of the panel is 2 – 13.5 m. Longer panels (of maximum 15m length) and shorter than 2m can be manufactured provided the technical department has been consulted.In case the length of the roof is higher than the standard delivery length of the panels, roof panels can be assembled by joining together 2 panels head-to-head and by overlapping the outer sheet of the panel from crest, on a distance of 150-250mm, depending on roof pitch.Dimensions of overlaps depending on roof pitch:- for pitch P >15% - minimum 150mm overlap;- for pitch P ≤ 15% - minimum 250mm overlap.Pre-cutting of panels (cutting the interior steel sheet and the core) to a required dimension, is a procedure that can be performed in the factory. Removal of the interior steel sheet and the core, from the area that is to be overlapped, shall be performed in site.

11

1

2

3

42

1

3

4

Pre-painted galvanized steel sheet, according to EN 10143, EN 10346 and EN 10169 current editions. Micro-profiles: STANDARD

Core: Polyurethane foam PUR or PIR (not harmful).

Sealing gasket: provides good thermal insulation and the joints’ tightness.

Self-drilling screw with pulley and EPDM gasket.

Metal cap with gasket.5

5

THERMAL INSULATING ROOF PANEL WITH 3 RIBS

Dimensional tolerances, under EN 14509:2013

Thermal-insulating panels

Standard colors:

Note: The company reserves its right to change the standard colors range, without any prior notification!

RAL 9002

RAL 9006

RAL 5010

RAL 3011

RAL 3000

RAL 9007

RAL 6005

RAL 7016

WIGTH THICKNESS (D) ≤ 100 mm THICKNESS (D) > 100 mm

± 2 mm± 2 mm

± 2%

LENGHT ≤ 3000 mmLENGHT > 3000 mm

Deflection to squareness

± 5 mm± 10 mm

6 mm

ON REQUEST

Computing values, wind load under pressure [kN/m2]Weight

Permissible distance between supports [m]

Page 12: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

12

Permissible loads:

U* - thermal transfer coefficient. U1 - thermal transfer coefficient, considering the profile's geometry of the panel and the thermal influence of the joint.U2 - thermal transfer coefficient, considering the profile's geometry of the panel. *Calculation according to EN 14509:2013, Method (A.10)The standard length of the panel is 2 – 13.5 m. Longer panels (of maximum 15m length) and shorter than 2m can be manufactured provided the technical department has been consulted.In case the length of the roof is higher than the standard delivery length of the panels, roof panels can be assembled by joining together 2 panels head-to-head and by overlapping the outer sheet of the panel from crest, on a distance of 150-250mm, depending on roof pitch.Dimensions of overlaps depending on roof pitch:- for pitch P >15% - minimum 150mm overlap;- for pitch P ≤ 15% - minimum 250mm overlap.Pre-cutting of panels (cutting the interior steel sheet and the core) to a required dimension, is a procedure that can be performed in the factory. Removal of the interior steel sheet and the core, from the area that is to be overlapped, shall be performed in site.

2

1

3

4

Pre-painted galvanized steel sheet, according to EN 10143, EN 10346 and EN 10169 current editions. Micro-profiles: STANDARD

Core: Polyurethane foam PUR or PIR (not harmful).

Sealing gasket: provides good thermal insulation and the joints’ tightness.

Self-drilling screw with pulley and EPDM gasket.

Metal cap with gasket.

A panel designed for roofs having a minimum slope of 7%, (the maximum slope is given in the project).

1

2

3

4

5

5

THERMAL INSULATING ROOF PANEL WITH 5 RIBS

Dimensional tolerances, under EN 14509:2013

WIDTH THICKNESS (D) ≤ 100 mm THICKNESS (D) > 100 mm

± 2 mm± 2 mm

± 2%

LENGHT ≤ 3000 mmLENGHT > 3000 mm

Deflection to squareness

± 5 mm± 10 mm

6 mm

Standard colors

Note: The company reserves its right to change the standard colors range, without any prior notification!

RAL 9002

RAL 9006

RAL 5010RAL 3011

ON REQUEST

Computing values, wind load under pressure [kN/m2]Weight

Permissible distance between supports [m]

Page 13: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

13

Thermal-insulating panels

Permissible loads:

U* - thermal transfer coefficient. U1 - thermal transfer coefficient, considering the profile's geometry of the panel and the thermal influence of the joint.U2 - thermal transfer coefficient, considering the profile's geometry of the panel.

The standard length of the panel is 2 – 10 m. Any other lengths can be manufactured provided the technical department has been consulted.

2

1

3

4

Pre-painted galvanized steel sheet, according to EN 10143, EN 10346 and EN 10169 current editions. Micro-profiles: STANDARD

Core: Polyurethane foam PUR (not harmful).

Fiber-glass resistant to micro-organisms, bacteria and acids – usually met in farms. Thickness 0.5 mm. Color: white opaque.

Self-drilling screw with pulley and EPDM gasket.

Metal cap with gasket.

Can be assembled on inclined structures having a minimum slope of 7%, (the maximum slope is given in the project).1

2

3

4

5

5

THERMAL INSULATING ROOF PANELIsoAgro3, IsoAgro5(for agro-zoo-technical applications)

fibră de sticlă 0.50mm

fibră de sticlă 0.50mm

Standard colors IsoAgro5:

RAL 9002

RAL 9006

RAL 5010RAL 3011

Standard colors IsoAgro3:

Note: The company reserves its right to change the standard colors range, without any prior notification!

RAL 9002

RAL 9006

RAL 5010

RAL 3011

RAL 3000

RAL 9007

RAL 6005

RAL 7016

Dimensional tolerances

LENGHT 2.000 - 4.000 mmLENGHT > 4.000 mm

Deflection to squareness

± 10 mm± 15 mm

5 mm

WIDTHTHICKNESS (D) = 40 mm

THICKNESS (D) = 50, 60 mm THICKNESS (D) = 80, 100 mm

± 7,5 mm± 3 mm ± 4 mm

+ 6, - 4 mm

Note: The company reserves its right to change the standard colors range, without any prior notification!

Permissible distance between supports [m]

Computing values, snow load [kN/m2]Weight

ON REQUEST

ON REQUEST

Page 14: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

14

2

1

3

4

2

1

3

4

Bituminized cart – allows the furtherwaterproofing of the roof.

Core: Polyurethane foam PUR (not harmful).

Pre-painted galvanized steel sheet, according to EN 10143, EN 10346 and EN 10169 current editions. Micro-profiles: STANDARD

Self-drilling screw with.

A panel having one bituminized cart face, designed for roofs that are going to be insulated later on, with bituminized or other kind of membranes. Waterproofing shall be done on the construction site. Minimum slope of 2%.

Permissible loads:

The standard length of the panel is 2 – 10 m. Any other lengths can be manufactured provided the technical department has been consulted.

THERMAL INSULATING ROOF PANEL HAVING ONE BITUMINIZED CART FACE

Standard colors:

Note: The company reserves its right to change the standard colors range, without any prior notification!

RAL 9002

RAL 9006

RAL 5010RAL 3011

Dimensional tolerances

LENGHT 2.000 - 4.000 mmLENGHT > 4.000 mm

Deflection to squareness

± 10 mm± 15 mm

5 mm

WIDTHTHICKNESS (D) = 60 mm

THICKNESS (D) = 80, 100 mm

± 7,5 mm± 4 mm

+ 6, - 4 mm

U* - thermal transfer coefficient. U1 - thermal transfer coefficient, considering the profile's geometry of the panel and the thermal influence of the joint.U2 - thermal transfer coefficient, considering the profile's geometry of the panel.

ON REQUEST

Permissible distance between supports [m]

Computing values, snow load [kN/m2]Weight

Page 15: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

THERMAL INSULATING WALL AND ROOF PANEL IsoSanon, IsoSanoa , IsoSano3, IsoSano5ISOSANO thermal insulating panels are provided with an interior galvanized steel sheet covered with a PVC film.

Applications:• IsoSanon, IsoSanoa - wall panel for applications with strict hygiene (phamaceutically industry, milk and meat processing industry, laboratories, etc.).• IsoSano3, IsoSano5 - roof panels that can be used in agro-zoo-technical applications.

Can be used in environments up to 100% relative humidity.Can not be used for surfaces that come into contact with UV rays.WE STRONGLY RECOMMENDED THE STORAGE TO BE PERFORMED IN COVERED ENVIRONMENTS!

This type of material allows easy cleaning and has a high resistance to various stains (butter, margarine, vegetable oils, vinegar, lubricating oils, fruit acids, lactic acids, caustic solutions, various edible oils etc).Maintenance is recommended to be done with water and a neutral soap.Use a soft sponge and avoid the use of aggressive products or solvents such as acetone, toluene, ethyl acetate and similar substances.

15

IsoSano N – Visible joint thermal insulating wall panel, that can be manufactured with one or both faces made of galvanized steel sheet covered with a PVC film.

MAINTENANCE

TYPES OF PRODUCTS

IsoSano3, IsoSano5 - 3 and 5 ribs roof panels, having the interior face made of galvanized steel sheet covered with a PVC film - recommended for agro-zoo-technical environments, thanks to its high resistance to aggressive agents.

lis-lis

IsoSano A - Hidden joint thermal insulating wall panel, that can only be manufactured with its interior face made of galvanized steel sheet covered with a PVC film; the exterior face is pre-painted galvanized steel sheet.

standard-lis

Thermal-insulating panels

Page 16: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

The steel sheet faces (0,4 ÷ 0,6mm) of the thermal insulating panel are made of two hot-dipped pre-painted galvanized steel sheet support layers - grade S250GD, (according to EN 10143, EN 10346 and EN 10169).

The exterior face has a 25µm polyester paintPrimer - foaming rough-cast layerPhosphate layerZinc layer

Steel

Zinc layerPrimer - foaming rough-cast layer

PRE-CUTTING OF PANELS

METAL FACES

16

Pre-cutting of panels (cutting the bottom steel sheet and foam core) can be performed directly in the factory.

Removing the foam core and the bottom steel sheet from the area that is going to be overlapped shall be performed on site.

Removing the foam core and the bottom steel sheet from the area that is going to be overlapped

shall be performed on site.

In order to achieve pre-cutting, theminimum length of the

panels shall be 5 m.

Page 17: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

Profiles made of cold formed galvanized steel are used mainly as secondary elements of the buildings' resistance structures, as roof purlins or wall rulers.During the past years, these elements have also been used for laying down the actual resistance structure of the buildings.

DESTINATION:C, U, Z and Σ profiles are used in constructions as:• Side-rods for fixing thermal insulating panels or corrugated sheets• Support and fixing profiles for doors and windows;• Purlins for supporting roof panels;• Elements for achieving the main resistance structure of the construction.

ADVANTAGES:• Easy and quick assembly;• Wide range of application, great flexibility;• Excellent corrosion resistance;• Increased accuracy of details;• High strength and rigidity;• Reduced costs for transport and assembly.

We provide profiles type Z, C, U and Σ, with the section height from 100 mm to 400 mm, thicknesses ranged 1-4 mm, lengths ranging 2 - 13.5 m (including oversized lengths up to 15m)

C Z

U∑

GALVANIZED PROFILES Z, C, U AND Ʃ

DESIGN AND CONSULTANCY SERVICESWe offer consultancy in choosing the best type of profiles for building the secondary structure and choosing the suitable type of panel.

Thanks to our team of designer engineers, we can provide complete structure and foundations projects, for building turnkey halls.

galvanized profiles

17

Page 18: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

ROOF AND WALL COVERING ELEMENTS MADE OF PROFILED STEEL SHEET

18

STRUCTURAL TRAYS

SINUS PROFILES

Constructive system:- structural tray;- mineral wool;- anti condensation foil;- trapezoidal steel sheet.

Outer covering of the disclosed system can be constructed of:- corrugated sheet, height of the rib =18mm;- trapezoidal sheet, height of the rib= 25mm;- trapezoidal sheet, height of the rib= 40mm;- architectural trays made of alucobond or steel.

Width(mm)

Width(mm)

Width(mm)

988

Width(mm)600

min=2max=13

0,450,500,600,751,00

4,374,855,827,279,70

Lenght(m)

Lenght(m)

Lenght(m)

min=2max=13,5

Lenght(m)

Thickness(m)

Thickness(m)

Thickness(m)

Weight(kg/m2)

Weight(kg/m2)

Weight(kg/m2)

1.085 min=2,5max=13,5

0,450,500,600,750,881,00

3,984,425,306,627,778,83

1.000 min=2max=13,5

0,450,500,600,751,001,25

4,314,795,757,199,58

11,97

PLS

120

x600

PLS

18x

76PL

S 2

5x18

0PL

S 4

0x25

0

TRAPEZOIDAL PROFILES

Structural trays are used as self-supporting elements in the system of roof and facade construction.

0,750,881,001,251,50

8,9910,5411,9714,9417,91

ThicknessX = 100

W e i g h t0,750,881,001,25

9,3711,0012,5015,62

X = 120

0,750,881,001,251,50

9,4811,1112,6215,7618,89

X = 125

0,750,881,001,25

9,8111,5113,0816,35

X = 130

0,750,881,001,251,50

9,9711,6913,2816,5319,87

X = 150

0,750,881,001,25

10,0111,7413,3516,68

X = 160

0,750,881,001,251,50

10,9512,8414,5818,2121,83

X = 200

NEW!

Thickness Thickness Thickness Thickness Thickness ThicknessW e i g h t W e i g h t W e i g h t W e i g h t W e i g h t W e i g h t

Page 19: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

840 min=2max=13,5

0,750,881,001,25

10,5112,3414,0217,52

PLS

141

x280

SELF-SUPPORTING SHEETSCorrugated sheets with high ribs (ranging 55 - 200mm) can be used in roofing structures as self-supporting structures = self-supporting sheet.The profiles can be used both for insulated and uninsulated roofs.

Constructive system of insulated roofs is made of:- self-supporting sheet;- vapor barrier;- rigid mineral wool (one or more layers);- waterproofing membranes of PVC, TPO or other materials.

1.050 min=2max=13,5

0,750,881,001,25

8,419,87

11,2114,02

PLS

85x

262

870 min=2max=13,5

0,750,881,001,25 1,50

10,1511,9113,5316,9220,30PL

S 1

53x2

90roofing elements

19

Width(mm)

Lenght(m)

Thickness(m)

Weight(kg/m2)

Width(mm)

Lenght(m)

Thickness(m)

Weight(kg/m2)

Width(mm)

Lenght(m)

Thickness(m)

Weight(kg/m2)

Page 20: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

Terasteel manufactures and supplies a wide and complete variety of standard and customized flashings, providing consul-tancy in choosing the proper ones. Flashings are delivered in same RAL color, as the panels.

Available colors: standard RAL colors of the panels’ metal faces

Materials: pre-painted galvanized steel sheet; Thickness: 0.50 mm.

Wall-roof joint concealing profile

(exterior)

Wall-roof joint concealing profile

(interior)

Casing (lid)

Fascia board

Exterior corner profile

Interior corner profile

Under-crest

Exterior crest

Covering profile

Base flashing

CLOSING ACCESSORIES

FLASHINGS

20

Page 21: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

OBS.: It is recommended to fasten the roof panels onto the support wedges, using an appropriate number of screws, depending on the ribs (minimum 3). It is recommended to use metal caps for each screw. It is recommended to fasten the wall panels onto the support wedges, using at least 3 screws per width of panel. It is mandatory to increase the number of screws when fastening the panels to the building’s edges.

(self-drilling screws made of galvanized steel, with pulley and sealing gasket, can be provided in any RAL color)

SCREWS

Metal structures of thicknesses up to 6mm

APPLICATIONType of panel - thickness DIMENSION OBS

IsoPer - 30, 40IsoPer - 50,60IsoPer - 80, IsoAc - 30, 40IsoPer - 100, IsoAc - 50,60IsoPer - 120, IsoAc - 80IsoAc - 100IsoAc - 120, IsoFrig - 150

6,3 x 62 v166,3 x 82 v166,3 x 102 v166,3 x 122 v166,3 x 152 v166,3 x 172 v166,3 x 195 v16

Refrigerating enclosures APPLICATIONType of panel - thickness DIMENSION

IsoFrig - 150IsoFrig - 200

6,3 x 195 v16 inox6,3 x 245 v16 inox

Wooden structures

IsoPer - 30, 40, 50IsoPer - 60, IsoAc - 30IsoPer - 80, IsoAc - 40, 50IsoPer - 100, IsoAc - 60IsoAc - 120, IsoAc - 80, 100IsoAc - 120

6,3 x 100 GTW6,3 x 120 GTW6,3 x 140 GTW6,3 x 160 GTW6,3 x 210 GTW6,3 x 260 GTW

RIVET for joining by overlapping the sheet profiles

Concrete structuresAPPLICATION

Type of panel - thickness DIMENSION

IsoPer - 30, 40, 50IsoPer - 60, IsoAc - 30IsoPer - 80, IsoAc - 40, 50IsoPer - 100, 120, IsoAc - 60, 80IsoAc - 100IsoAc - 120

6,3 x 100 BS6,3 x 120 BS6,3 x 140 BS6,3 x 160 BS6,3 x 180 BS6,3 x 200 BS

OBS

IsoPer - 30IsoPer - 40IsoPer - 50, 60IsoPer - 80, IsoAc - 30, 40IsoPer - 100, IsoAc - 50, 60IsoPer - 120, IsoAc - 80IsoAc - 100, 120, IsoFrig - 150IsoFrig - 200

6,3 x 70 v16 6,3 x 80 v166,3 x 95 v166,3 x 115 v166,3 x 135 v166,3 x 155 v166,3 x 195 v166,3 x 235 v16

Metal structures of thicknesses up to 12mm

APPLICATIONType of panel - thickness DIMENSION OBS

APPLICATIONType of panel - thickness DIMENSION OBS

METAL CAPSUsed for reinforcement of fixings of the roof panels.Provide stability and safety. May be delivered in all RAL colors.

COVERS (LIDS)Upon request, covers can be delivered

having the same color as the façade panels

21

closing accessories

Page 22: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

Functions of smoke evacuation traps:

• Evacuation of smoke and hot gases (the main function that defines this product). The opening command may be automatically and manually;• Daily-ventilation is an optional feature ensuring the increase of comfort. Its activation can be automatically or manually.•Natural lighting – achieved by means of glazed surface, which can be: opal colored or transparent polycarbonate of 10 or 16mm, or thermally processed acrylic glass having 1, 2 or 3 layers• Roof access.

CU 5 NERVURI

Flat skylight made of cellular polycarbonate, thickness of 30mm. It shall only be installed starting from crest to eaves (overlapping the sandwich panel is not permitted).

Width: 1000mmU = 1.3W/m2*K

Expandable adhesive gasket 20 mm * 20 mm - shall be fixed along the side wings - between the rib of the panel and the rib of the skylight

sandwich panel

flat panel

expandable adhesive gasket 20 mm * 20mm

LIS

Five ribbed skylight, made of cellular polycarbonate, thickness of 10 and 16 mm. Used to obtain bright light strips in roof’s plane made of sandwich panels or corrugated sheets. It can be installed from crest, up to a point where it may overlap with the 3 or 5 ribs sandwich panels, or from crest to the eaves.

Width: 1000mmU=2.6 W/m2*K (skylight with thickness of 10 mm)U=2 W/m2*K (skylight with thickness of 16 mm)

5 RIBBED

All skylights are provided with UV protection on the exterior side

SKYLIGHTS

SMOKE EVACUATION TRAPS

22

(flat)

BEAM

Page 23: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

We provide the entire range of PVC sanitary accessories and profiles for finishing refrigerating stores and enclosures,but also for other applications requiring severe thermal and sanitary conditions.

Industrial doors are provided with the following features :• 4cm thick sandwich panels;• High resistance steel hardware• Gates are balanced by steel torsion spring – 50.000 openings;• Standard doors include protection against spring-breaking, cable-breaking and finger-clutching;• Panels can be accessorized with pedestrian access doors, glazed panels, different types of windows etc;• Doors can be opened: manually (operated by chain gearbox), or automatically (operated by remote control/power button panel);• Supplied with rubber seal around the perimeter;• Galvanized rails, thickness 2mm.Standard exterior colors: RAL 9002 white, RAL 9006 silver, RAL 5010 blue, RAL 7016 anthracite grey, RAL 3000 red fire.nterior color: RAL 9002 white

SANITARY PROFILES

INDUSTRIAL DOORS

SEALING TAPES

SELF-ADHESIVE TAPE MADE OF PE POLYETHILENE PE (thickness 3mm x width 20mm)

Applicability: - Sealing sandwich panels joints- Sealing joint gaps of sheet trays

BUTIL TAPE SF900(thickness 2mm x width 8mm)High performance Elastomer polymer extruded on special paper. Provides optimum sealing against water and moisture. Applicability: Sealing of the sheet’s sewings.

23

closing accessories

Page 24: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

Classification regarding fire characteristics (PIR core)Classification : Fire resistanceISOPERnRF D = 50 and 60 mm EI 20 E 90 ISOPERnRF D = 80, 100, 120 mm EI 30 E 30 ISOFRIGRF D = 150, 200 mm EI 30 E 30 ISOPERaRF D = 80, 100 mm EI 30 E 60 ISOAC3RF D = 50 and 60 mm REI 20 RE 30 ISOAC3RF D = 80, 100, 120 mm REI 30 RE 30 ISOAC5RF D = 50 and 60 mm REI 15 RE 30 ISOAC5RF D = 80, 100, 120 mm REI 30 RE 60

Classification : Fire reactionISOPERnRF [30-200 mm] B-S2, d0ISOPERaRF [40-100 mm] B-S2, d0ISOAC3RF [30-120 mm] B-S2, d0ISOAC5RF [30-120 mm] B-S2, d0

Classification regarding fire characteristics (PUR core)Classification : Fire reactionISOPERn [30-200 mm] D-S3, d0 ISOPERa [40-100 mm] D-S3, d0ISOAC3 [30-120 mm] D-S3, d0ISOAC5 [30-120 mm] D-S3, d0

Density - 35-40 kg/m3

Other tests performed

Airborn sound insulationISOPERn 40 - RW (C;Ctr) = 28 (-3;-4) dB ISOAC5 80 - RW (C;Ctr) = 27 (-2;-5) dB

E - IntegrityI - InsulationR - load bearing capacity

* mark is applied on sandwich panels with two

metal faces and on galvanized profiles Z, C, U and Ʃ

21

CLASSIFICATIONS

24

Page 25: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

KITS FOR “HOME DELIVERY” TURNKEY HALLS

PRODUCTION HALL CHARACTERISTICS:• Length: 20 m• Width: 10 m

• Eaves height: 4 m• Span: 5 m

HEADQUARTERS + WAREHOUSE HALL CHARACTERISTICS:• Length: 25 m • Width: 14 m

• Eaves height: 4,8 m• Span: 5 m

• one floor on first span

SERVICE HALL CHARACTERISTICS:• Length: 25 m • Width: 12 m

• Eaves height: 4 m• Span: 5 m

* On request we can offer other types of halls!

25

turnkey halls

Page 26: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

21

3

4

567

8

9

10

11

12

13

1415

2

1

3

4

5

Main metal structure

Secondary metal structure

Roof panel

Wall panel

Crest profile

6

7

8

9

10

Under-crest profile

Gable concealing profile (fascia board)

Socle flashing

Exterior corner profile

Wall/roof joint concealing profile

11

12

13

14

15

Self-supporting rectangular gutter

Carpentry concealing profile

PVC/ aluminium carpentry (window)

Translucent polycarbonate skylight

Smoke evacuation trap

26

Page 27: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

Austria Azerbaijan Bulgaria Croatia Czech Republic England France Germany Hungary Latvia Netherlands Norway Republic of Moldova Russia Serbia Slovakia Slovenia Switzerland Ukraine

Page 28: Terasteel · Pre-made modules (container type) Interior divisions of any type of constructions Agro-zoo-technical buildings Applications relying on strict hygiene (laboratories, pharmaceutical

2017

Edi

tion

TERASTEEL SA427298 România, jud. Bistrița-Năsăud,DN15A km. 45 + 500 (Bistrița - Reghin)Crainimăt, comuna Șieu-Măgheruș

Tel.: 004-0263-238.202Fax: 004-0263-342.276Mobil: 004-0729-258.181

e-mail: [email protected]