techzone · 2018-12-27 · 7 metal mineral fibre techzone main runners have slots at every 150mm....
TRANSCRIPT
1
TECHZONE
CEILING SYSTEMS &
TECHNICALGUIDE
IntegratedCeiling
Solutions
T
T
T
T
T
T
T
T
T
8'-4" 8'-4"
4'
4'
MAIN
MAIN
48"
CT
48"
CT
48"
CT
48"
CT
48"
CT
Leave the “noise” behind – the clutter of lighting,
air diffusers and returns, sprinkler systems, and
unwanted sound – that busy the ceiling plane.
TechZone easily organizes these systems into
150mm wide technical zones.
A range of compatible fixtures from our partner
companies have been prequalified for fit
and finish.
The result – a clean, monolithic look, using
standard ceiling panels and suspension systems.
organized. simple. clean.
42 3
Choose a Compatible Suspension System
Choose Your Perimeter Treatment
Choose Your Field & Technical Panels
Mineral Fibre
Metal
Soft Fibre
TechnicalPanel
1
Design Your Layout
2
TECHZONECeiling SystemsChoose Your Perimeter
Treatment
3
4
Open Space
Par t i t i oned Of f i ces and Meet ing Rooms w i th open spaces
Ca l l Cen t re
Confe rence Room
Recept ion Area
ShopsShowroom
1200mm
1200
mm
1200
mm
1350mm
600mm
1200
mm
1350mm
1200mm
1500mm
600m
m12
00m
m
1350mm
600m
m12
00m
m
1500mm
1350mm
1200mm
600m
m12
00m
m
1200mm
1200
mm
1350mm
1350mm
1200
mm
1500mm
Armstrong TECH ZONE is easy to specify and install.
Armstrong TECH ZONE is compatible with the more popular building module - 1200mm. The technical zone can be installed parallel or perpendicular to the façade. The combinations of suspension systems, tiles and technical elements are almost unlimited. The following illustrations give you a flavour of what you can achieve.
To specify and design a system, you just have to follow the following steps:1 Select the ceiling module.2 Determine the on-centre spacing of the linear technical zone.3 Choose the TZ orientation, field panel type and dimensions. 4 Select the edge detail and the grid that’s compatible with Armstrong TECH ZONE.5 Select the material of the Technical Panel.
Choose the Technical Elements to be integrated. Although building modules can vary country to country, Armstrong can provide a solution to meet your individual needs.
DESIGN Y O U R LAYOUT
1
5
Section Drawing Suspension Field Panel Technical Panel or Systems Edge Details Technical Elements Edge Details
Prelude 38 Board Board Prelude 38 Tegular 8 mm Tegular 8 mm ANG Tegular ANG Tegular
Suprafine 38 Bevelled Tegular/ Bevelled Tegular/ MicroLook 8 mm MicroLook 8 mm
Silhouette 38 Bevelled Tegular/ Bevelled Tegular/ MicroLook 8 mm MicroLook 8 mm
Examples of edge details are shown below
Tegular Field Panel &
Tegular Technical Panel on
Prelude 38.
Tegu la r Mic ro look S i lhoue t teBoard
EDGE DETAIL
Bevelled Tegular/MicroLook Field
Panel & Bevelled Tegular/
MicroLook Technical Panel on
Suprafine 38.
Bevelled Tegular/MicroLook Field
Panel & Bevelled Tegular/
MicroLook Technical Panel on
Silhouette 38.
Board Field Panel and Board
Technical Panel on Prelude 38.
Matching edge details of the Field Panel, Technical Panel or Technical Element.Technical Panels width:
150 or 300*mm.
Technical Panels lengths:
1200, 1500*mm.
Tiles Performances Steel Angle Edge Detail Absorption Attenuation Light Humidity Recycled Reflectance Resistance Content*
Optra Board, Tegular, Semi-concealed, 0.90 N/A 85% 95% 66(GW)/74(RW)% Bev. Tegular • • • Ultima Board, Tegular, 0.70 37 88% 99% 62% only Field Panel
Bev. Tegular • • • Dune Max Tegular, Semi-concealed, 0.70 31 85% 99% 63% only Field Panel
Bev. Tegular • • • Dune Tegular, Semi-concealed, 0.50 33 85% 99% 32% Bev. Tegular • • • Metalworks Microlook 0.70# 30-40* 68%◊ 95% upto 25% • •
Prel
ude
38Su
praf
ine
38Si
lhou
ette
38
* to be introduced.
# For standard perforated when used with soundtex fleece
* For unperforated
◊ For standard perforated when used with black acoustical fleece
CHOOSE Y O U R FIELD & TECHNICAL PANEL
2
6
Prelude 38 grid
*TO BE INTRODUCED
Suprafine 38 grid
Silhouette 38 grid
Prelude 38 grid
The technical zone length depends on the selected ceiling module.
Prelude 38 Suprafine 38/ Silhouette 38
Nominal length of technical zone in mm Nominal opening in mm
1200 1176 1185
1500* 1476 1485
126150
126150
135150
285300
276300
3838 38
38276300
38
135150
285300
3838
for 150 mm technical zone
for 300 mm technical zone(to be introduced)
TECHNICAL ZONE WIDTH AND LENGTH
TECHNICAL ZONE LENGTH
PRELUDE38 SILHOUETTE38SUPRAFINE38
CHOOSE Y O U R COMPATIBLE SUSPENSION SYSTEM
3
7
METAL
MINERAL
FIBRE
TechZone Main Runners have slots at every 150mm. (Silhouette MR with Custom rout & mitre cut location)
To create a technical zone, Cross Tees can be fixed every 150mm for integration of the 150mm wide
lighting fixtures and air diffusers recommended by the Armstrong Tech Zone partners. For integration of larger Technical Elements, such as
chilled beams, the Cross Tees can be fixed at 300mm distance.
6"
48" / 60"
6"
48" / 60"
6"
48" / 60"
6"
48" / 60"
6"
48" / 60"Cross Section: Board with Prelude 38
Cross Section:
Tegular with Prelude 24/Microlookwith Suprafine 38
MicroLook with Silhouette 38
Cross Section: Tegular with Prelude 38 /
MicroLook with Suprafine 38
150mm75mm
Mineral Tegular /MicroLook
Technical Panel
Metal Tegular / MicroLook
Technical Panel
Mineral BoardTechnical Panel
Longitudinal Section: Board with Prelude 38
Longitudinal Section: MicroLook with Suprafine 38
MicroLook with Silhouette 38Cross Section:
Longitudinal Section:
Longitudinal Section: Tegular with Prelude 38 / MicroLook with Silhouette 38
Cross Section: MicroLook with Silhouette 38
Longitudinal Section: MicroLook with Silhouette 38
DESIGN DETAILS
8
A. Select Perimeter angle at wall
19
19
19
7
7
14
Shadowline Molding 'L' Angle Molding
B. Select perimeter trim at floating edge
CHOOSE Y O U R PERIMETER TREATMENT
4A. Wall to Wall installation B. Cloud/Floating installations C. Elevation or material transitions
in the ceiling plane
Main Runner
Linear Diffuser
Main Runner
Flexible Sprinkler
Field Panel
Main Runner
Top of partition
Universal Partition Clip
Cross Tee
Cross Tee
Technical Panel
Technical Panel
Field Panel
Cross Tee Main Runner
Partition Wall
Universal Partition Clip
Technical Panel
Recessed Lighting Fixture
Main Runner
Cross Tee
Main Runner
Flexible Sprinkler
Axiom Profile
Drywall Grid System Main Runner
Drywall Grid System Cross Tee
Plasterboard
Technical Panel
Technical Panel
Direct Load Ceiling Clip
9
Axiom profile perimeter upstand detail - Techzone to plasterboard
Partition head detail fixing to Prelude 38 / Suprafine 38
TechZone Load Capacity
As with any other ceiling system, TECH ZONE has maximum load capacities. However, as TECH ZONE differs from traditional ceiling systems and offers much more flexibility in ceiling layouts, the maximum load capacities will vary from solu-tion to solution. To show all the possible combinations of suspension systems, panels and TECH ZONE partners products, LOAD CApACITy TAbLES are included on page 14.
B. Select perimeter trim at floating edge
Drywall Transition – Drywall to Acoustical Ceilings
Drywall Surround with Acoustical Ceiling
ArmstrongExposed TeeGrid System
Gypsum BoardVaries
Exposed Tee1200 mm
1200 mm
1200 mm
Cross Tee150 mm Apart for
Technical Zone
Cross Tee Apart for
panels
TechZ
MBSC Clip
one OPTRA,
Dune Max, Dune or Metal
Technical Panel
TechZone OPTRA, Dune, Dune Maxor Metal Technical Panel
#12 Hanger Wire
ChannelMolding
Exposed TeeMain Beam
Exposed TeeMain Beam
Exposed TeeMain Beam
Wall
Exposed Tee1200 mm Cross Tee
150mm Apart forTechnical Zone
1200 mm
1200 mm Cross Tee
Apart for
panels
TechZone OPTRA,DUNE MAX, DUNE,or Metal Technical Panel
PRELUDEMain Beam
PRELUDECross Tee
ChannelMolding
Back Brace
DrywallGrid System
Drywall soffit
Exposed TeeMain Beam
Exposed TeeMain Beam
Drywall Grid Soffit
Exposed TeeMain Beam
TechZone OPTRA, DUNE MAX, DUNEor Metal Technical Panel
C. Select transition components
10
11
Installing Main Runners parallel to the technical zone allows for integration of continuous lighting option within the system.
INSTALLATION
How to install Armstrong
TECH ZONE ceiling system
in 3 steps:
1
2
3
Simple and fast assembly of
Armstrong TECH ZONE
suspension systems to
create 150 or 300mm* wide techni-
cal zones, for
luminaires, air diffusers, sprinklers,
chilled beams and loudspeakers.
Perfect integration of
made-to-measure
Technical Elements.
Installation of made-to-measure ceil-
ing tiles, including 150 or 300mm*
wide Technical Panels.
TECH ZONE combines:- Suspension Systems,
- Field Panels (FP, installed between technical zones),
- Technical Panels (TP, installed in technical zones),
- Technical Elements (TE: Luminaires, air diffusers… installed in technical zones).
Suspension system
Field Panel (FP)
Technical Panel (TP)
Technical Element (TE)
Option 1: Main Runners perpendicular to the technical zone
Option 2: Main Runners parallel to the technical zone
Main Runner
Main Runner
Cross TeeMain Runner
Air Diffuser
Recessed Lighting FixtureCross Tee 1200mm
Main Runner
* to be introduced.
In case it is required to integrate continuous luminaires or Technical Elements of different lengths,the Main Runners need to be installed parallel to the technical zone and
small Cross Tees need to be added wherever necessary.
Installing Main Runners perpendicular to the technical zone establishes set Technical Panel sizes for the integration of Technical Elements.
12
Module 1200 x 1200mm - 1200mm on-centre technical zone spacing
Module 1200 x 1350mm - 1350mm on-centre technical zone spacing
TZ2 Layout available with Silhouette 38 grid
TZ4 (FP2) Layout available with Silhouette 38 grid* For TZ4 only# Available in Galvanised Steel 0.5 mm thk - Plain, Standard Perforated, Microperforated
Step 1 Step 2 Step 3 Step 4 Step 5Ceiling TechZone TZ Type Size 24 mm 24mm 24mm 15mm TechZone Technical Panel Module on centre Orientation mm Board Tegular Semi Bevelled Optra Dune Dune Metal mm spacing concealed* Tegular Max
1200 1350 TZ3,TZ4 Optra 1200X1200 · · · · · ·
1200 1350 TZ3,TZ4 Optra 600X1200 · · · · · ·
1200 1350 TZ3,TZ4 Ultima 600X1200 · · ·
1200 1350 TZ3,TZ4 Dune Max 600 X1200 · · · · · ·
1200 1350 TZ3,TZ4 Dune 600X1200 · · · · · ·
1200 1350 TZ3,TZ4 MetalWorks# 600X1200 . . ·
1200 1350 TZ3,TZ4 MetalWorks# 300X1200 . . ·
1200 1350 TZ4 Optra 300X1200 . . · . · ·
1200 1350 TZ4 Dune Max 300X1200 . . · . · ·
1200 1350 TZ4 Dune 300X1200 . . · . · ·
TZ 1 With Main Runners perpendicular to the technical zone
mm0021
1200mm
600m
m
1050mm150mm
MR
CT2
CT1
FP2
FP1
TZ 2 With Main Runners parallel to the technical zone
mm0021
1200mm
600m
m
1050mm150mm
FP2
FP1
CT2
CT1
mm0021
1350mm
1200mm150mm
600m
m
mm0021
1350mm
1200mm150mm
600m
m
TZ 3 With Main Runners perpendicular to the technical zone
TZ 4 With Main Runners parallel to the technical zone
FP1 FP1FP2 FP2
FP2 FP2
CT1
CT1
CT2
CT1
MR
MR
Step 1 Step 2 Step 3 Step 4 Step 5Ceiling TechZone TZ Type Size 24 mm 24mm 24mm 15mm TechZone Technical PanelModule on centre Orientation mm Board Tegular Semi Micro Optra Dune Dune Metal mm spacing concealed look Max
1200 1200 TZ1,TZ2 Optra 1200X1050 · · · · ·
1200 1200 TZ1,TZ2 Optra 600X1050 · · · · ·
1200 1200 TZ1,TZ2 Dune 600X1050 · · · ·
1200 1200 TZ1,TZ2 Dune Max 600X1050 · · · ·
CONFIGURATION DRAWINGS AND pRODUCT COMpATIbILITy
13
Module 1200 x 1500mm - 1500mm on-centre technical zone spacing
Module 1200 x 1950mm - 1950mm
on-centre technical zone spacing
Module 1200 x 1650mm - 1650mm
on-centre technical zone spacing
Step 1 Step 2 Step 3 Step 4 Step 5Ceiling TechZone TZ Type Size 24 mm 24mm 24mm 15mm TechZone Technical PanelModule on centre Orientation mm Board Tegular Semi Micro Optra Dune Dune Metal mm spacing concealed* look Max
1200 1500 TZ5,TZ6 Optra 600X1350 · · · · · ·
1200 1500 TZ5,TZ6 Dune Max 600X1350 · · · · · ·
1200 1500 TZ5,TZ6 Dune 600X1350 · · · · · ·
1200 1500 TZ5, TZ6 MetalWorks# 600x1350 . . .
Step 1 Step 2 Step 3 Step 4 Step 5Ceiling TechZone TZ Type Size 24 mm 24mm 24mm 15mm TechZone Technical PanelModule on centre Orientation mm Board Tegular Semi Bevelled Optra Dune Dune Metal mm spacing concealed Tegular Max
1200 1950 TZ7 Optra 600X1200 · · · · ·
1200 1950 TZ7 Ultima 600X1200 · · ·
1200 1950 TZ7 Dune Max 600x1200 · · · · ·
1200 1950 TZ7 Dune 600X1200 · · · · ·
1200 1950 TZ7 MetalWorks# 600x1200 · ·
1200 1650 TZ8 Optra 750x1200 · · · · ·
1200 1650 TZ8 Optra 600X1500 · · · · ·
1200 1650 TZ8 Dune Max 600X1500 · · · ·
1200 1650 TZ8 Dune 600X1500 · · · ·
1200 1950 TZ7 MetalWorks 600x1500 . . .
mm006
1500mm
mm0021
1350mm150mm
mm006
1500mm
mm0021
1350mm150mm
TZ 5 With Main Runners perpendicular to the technical zone
TZ 6 With Main Runners parallel to the technical zone
FP FP
MR
MR
CT1CT2 CT1CT2
1650mm
1200
mm
1200
mm
FP2FP1 FP1
TZ 8 With Main Runners perpendicular to the technical zone
CT2
CT2
MR
MR
MR
CT1 CT1
CT1 CT1
1650mm1950mm on centre
1200
mm
1200
mm FPFPFP
TZ 7 With Main Runners perpendicular to the technical zone
MR
MR
MR
CT1
CT1
1800mm150mm 150mm
* For TZ6 only# Available in Galvanised Steel 0.5 mm thk - Plain, Standard Perforated, Microperforated
TZ6 Layout available with Silhouette 38 grid
CONFIGURATION DRAWINGS AND pRODUCT COMpATIbILITy
ASTM
L/3
60 S
tand
ard
TZ 1
FP 1: 1200x1050mm FP 2: 600x1050mm
FP 1 EF = 0.88 FP 2 EF = 0.88
MR EF = 0.83 MR EF = 0.83
CT1 EF = 1.67 CT1 EF = 1.67
- - CT2 EF = 0.88
TZ 3
FP 1: 1200x1200mm FP 2: 600x1200mm
FP 1 EF = 0.89 FP 2 EF = 0.89
MR EF = 0.83 MR EF = 0.83
CT1 EF = 1.48 CT1 EF = 2.22
TZ 5
FP 1: 1350x600mm
FP 1 EF = 0.90
MR EF = 0.83
CT1 EF = 1.33
CT2 EF = 0.75
TZ 6
FP 1: 1350x600mm *
FP 1 EF = 0.90
MR EF = 1.33
CT1 EF = 1.50
TZ 2
FP 1: 1200x1050mm * FP 2: 600x1050mm *
FP 1 EF = 0.88 FP 2 EF = 0.88
MR EF = 1.67 MR EF = 1.67
CT1 EF = 0.73 CT1 EF = 1.46
- - - -
TZ 4
FP 1: 1200x1200mm FP 2: 600x1200mm *
FP 1 EF = 0.89 FP 2 EF = 0.89
MR EF = 1.48 MR EF = 1.48
CT1 EF = 0.74 CT1 EF = 1.48
TZ 7
FP 1: 600x1200mm
FP 1 EF = 0.92
MR EF = 0.83
CT1 EF = 2.05
- -
TZ 8
FP 1: 750x1200mm FP 2: 600x1500mm
FP 1 EF = 0.91 FP 2 EF = 0.91
MR EF = 0.83 MR EF = 0.83
CT1 EF = 1.82 CT1
CT2
EF = 1.21
EF = 0.91- -
Use the following table to estimate the required quantities of grid components and Field Panels for the different TECH ZONE configurations. To do so, multiply the ceiling area (m2) by the Estimating Factor (EF) of each product. The quantity of Technical Panels and the number of small Cross Tees (150 & 300mm) will depend on the type and quantity of Technical Elements and are therefore not part of the calculation.
* For estimating factors of layouts with Silhouette grid, please get in touch with Armstrong representative.
Panel Type Kg/m2
Optra 15mm 1.8Optra 20mm 2.3Optra 25mm 2.8Dune 16mm 3.9Dune 18mm 4.4Dune Max 20mm 4.16Ultima+ 19mm 5.2Metal 4.4
14
Max Load 38 mmH Square Bulb Field Panel Options Prelude 38 mm Suprafine 38 mm Silhouette 38 Layout FP 1 FP 2 FP1 FP2 FP1 FP2 FP1 FP2 TZ 1 1200 x 1050 600 x 1050 14.5 14.5 13.3 13.3 - - TZ 2 1200 x 1050 600 x 1050 20.1 29.1 19.3 27.9 9.85 15.36 TZ 3 1200 x 1200 600 x 1200 10.1 - 9.7 - - - TZ 4 1200 x 1200 600 x 1200 13.4 25.8 12.8 24.8 - 13.2 TZ 5 1350 x 600 7.3 7.0 - - - - TZ 6 1350 x 600 18.7 17.9 - - 9.18 - TZ 7 1200 x 600 13.4 - 12.8 - - - TZ 8 1200 x 750 1500 x 600 5.4 5.4 5.2 5.2 - -
LOAD CApACITy FOR GRID COMpONENTS, FIELD pANELS & TECHNICAL ELEMENTS
CALCULATION FOR ALL CONFIGURATIONS
TECHZONE pARTNERS
Industry-leading suppliers have engineered and designed lighting, air diffusers/returns and fire protection products for use in TechZone Ceiling Systems. All Armstrong compatible products are prequalified for fit and finish. Look for the Armstrong TechZone Compatible sign of assurance on partner specification sheets.
CONTACT US