Technisches Datenblatt Z5 m, Z5 mlb, Z5 mlc Z5m-36-10/11 Z5m-40-08 Z5m-40-10/11/13 Z5m-50-08 Z5m-50-10/11 Z5m-50-10R/11R Z5m-50-13 ( ) Z5m Implantate Schulter- Ø in mm Schulter- Ø in mm Schulter- Ø in mm Schulter- Ø in mm Schulter- Ø in mm Schulter- Ø in mm Schulter- Ø in mm Ø 3.60 Ø 4.00 Ø 5.00 Ø 3.60LB Ø 4.00LB Ø 3.60LC Ø 4.00LC 8 mm 4.8 6.0 4.4 4.4 G25 4.4 G25 4.4 10 mm 4.6 4.8 6.0 4.4 4.4 G25 4.4 G25 4.4 10 mm Red. 5.4 11.5 mm 4.6 4.8 6.0 11.5 mm Red. 5.4 13 mm 4.8 6.0 G25 = Gingivahöhe 2.5 mm Eindrehinstrumente Z5m HA12 Z5m Handstück-Adapter 12 mm RA16 Z5m Ratschen-Adapter 16 mm RA24 Z5m Ratschen-Adapter 24 mm Eindrehinstrumente Z5m Lockball und LC Z5m-HA12lb Handstück-Adapter 12 mm für Lockball Z5m-RA16lb Ratschen-Adapter 16 mm für Lockball Z5m-RA24lb Ratschen-Adapter 24 mm für Lockball Z5m-RA16lc Ratschen-Adapter 16 mm für LC (Locator®) Zubehör für Z5m/Z5m(t) Implantate I36/I40/I50/I50R Abformkappen L36/L40/L50/L50R Laboranaloge* G36/G40/G50/G50R Gingivaformer geschlossen G36-0/G40-0/ G50-0/G50R-0 Gingivaformer offen * jede Grösse farbcodiert Zubehör für Z5m Lockball und LC Z5mlb-M2 Matrize für Z5mlb Z5mlb-O17 O-Ring zu Matrize Z5mlb Optimale Implantatauswahl (in Bezug auf Gewindedurchmesser): Unterkiefer Oberkiefer 3,6 Implantate nur an folgen- den Positionen als Einzelzahn- implantat verwenden: OK: 12, 22 / UK: 31, 32, 41, 42 Nicht für Brücken geeignet!

Upload: vandat

Post on 06-Mar-2018

221 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: Technisches Datenblatt Zm, Z mlb, Z mlczsystems.com/.../user_upload/pdf/z_tech_datenblatt_z5m_mlb_mlc.pdf · Technisches Datenblatt Z5m, Z5mlb, Z5mlc Z5m-36-10/11 Z5m-40-08 Z5m-40-10/11/13

Technisches Datenblatt Z5m, Z5mlb, Z5mlc

Z5m-36-10/11 Z5m-40-08

Z5m-40-10/11/13 Z5m-50-08

Z5m-50-10/11 Z5m-50-10R/11R Z5m-50-13

( )

Z5m Implantate Sc

hulte

r- Ø

in m

m

Schu

lter-

Øin

mm

Schu

lter-

Øin

mm

Schu

lter-

Øin

mm

Schu

lter-

Øin

mm

Schu

lter-

Øin

mm

Schu

lter-

Øin

mm

Ø3.60 Ø4.00 Ø5.00 Ø3.60LB Ø4.00LB Ø3.60LC Ø4.00LC 8mm ✓ 4.8 ✓ 6.0 ✓ 4.4 ✓ 4.4 ✓ G25 4.4 ✓ G25 4.410mm ✓ 4.6 ✓ 4.8 ✓ 6.0 ✓ 4.4 ✓ 4.4 ✓ G25 4.4 ✓ G25 4.410mm Red. ✓ 5.411.5mm ✓ 4.6 ✓ 4.8 ✓ 6.011.5mm Red. ✓ 5.413mm ✓ 4.8 ✓ 6.0

G25 = Gingivahöhe 2.5mmEindrehinstrumente Z5m

HA12 Z5m Handstück-Adapter 12 mm

RA16 Z5m Ratschen-Adapter 16 mm

RA24 Z5m Ratschen-Adapter 24 mm

Eindrehinstrumente Z5m Lockball und LC

Z5m-HA12lb Handstück-Adapter 12 mm für Lockball

Z5m-RA16lb Ratschen-Adapter 16 mm für Lockball

Z5m-RA24lb Ratschen-Adapter 24 mm für Lockball

Z5m-RA16lc Ratschen-Adapter 16 mm für LC (Locator®)

Zubehör für Z5m/Z5m(t) Implantate

I36/I40/I50/I50R Abformkappen

L36/L40/L50/L50R Laboranaloge*

G36/G40/G50/G50R Gingivaformer geschlossen

G36-0/G40-0/ G50-0/G50R-0 Gingivaformer offen

* jede Grösse farbcodiert

Zubehör für Z5m Lockball und LC

Z5mlb-M2 Matrize für Z5mlb

Z5mlb-O17 O-Ring zu Matrize Z5mlb

Optimale Implantatauswahl (in Bezug auf Gewindedurchmesser):

UnterkieferOberkiefer

3,6 Implantate nur an folgen-den Positionen als Einzelzahn - implantat verwenden: OK: 12, 22 / UK: 31, 32,41,42Nicht für Brücken geeignet!