M Series FULLY CONDENSING MODULATING LOW NOx GAS BOILER TECHNICAL DATA SHEET 70501 MODULATING OUTPUTS from 29kW to 472kW ATLANTIC BOILERS was formed in 1980, from a family boiler business first established back in 1923, to promote highly efficient boilerplant and to supply the first commercial gas condensing boilers in the United Kingdom in 1982. All editions of those boilers are running today and, since 1982, ATLANTIC BOILERS has consistently provided high grade condensing boilers based on smooth austenitic stainless steel. ATLANTIC BOILERS now introduce the latest compact, entirely stainless steel condensing boiler, the M SERIES, which is long-lasting and highly efficient at heat transfer The M SERIES joins the earlier E series range of stainless steel condensing boilers supplied successfully over twenty years to Universities, Hotels, Hospitals, Social Care Buildings, Leisure Centres, Offices and many other buildings. ATLANTIC BOILERS provides back-up commissioning, servicing and spares through leading merchants across the United Kingdom.

Upload: others

Post on 01-Feb-2022

24 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TECHNICAL DATA SHEET 70501

M SeriesFULLY CONDENSING MODULATING LOW NOx GAS BOILER

TECHNICAL DATA SHEET

70501

MODULATING

OUTPUTSfrom 29kW to 472kW

ATLANTIC BOILERS was formed in 1980, from a family

boiler business first established back in 1923, to promote

highly efficient boilerplant and to supply the first

commercial gas condensing boilers in the United Kingdom

in 1982. All editions of those boilers are running today

and, since 1982, ATLANTIC BOILERS has consistently

provided high grade condensing boilers based on smooth

austenitic stainless steel.

ATLANTIC BOILERS now introduce the latest compact,

entirely stainless steel condensing boiler, the M SERIES,

which is long-lasting and highly efficient at heat transfer

The M SERIES joins the earlier E series range of stainless

steel condensing boilers supplied successfully over twenty

years to Universities, Hotels, Hospitals, Social Care

Buildings, Leisure Centres, Offices and many other

buildings.

ATLANTIC BOILERS provides back-up commissioning,

servicing and spares through leading merchants across

the United Kingdom.

Page 2: TECHNICAL DATA SHEET 70501

The ATLANTIC M-Series Condensing Boiler has a patentedunique fully pre-mix burner with fail-safe ionisation flamesensor. Filtered air is drawn from the boiler room, which thenpasses through a Venturi where it mixes with the natural gassupply before passing through a variable speed centrifugalfan. The air/natural gas mix then passes vertically down acircumferential series of burner tubes where it is ignited to givea circular ‘carpet’ of flame running evenly from top to bottomof the combustion chamber. The air/natural gas volume and,therefore, the heat output can be modulated from 100% downto 25%.

Alongside the vertical burner tubes are a set of smoothaustenitic stainless steel water tubes where circulation of waterfrom the building heating system cools the burner combustionto improve the low NOx performance.

The ATLANTIC M-Series Condensing Boiler has two distinctheat exchangers surrounding the combustion chamber. Bothare manufactured from high grade smoothaustenitic stainless steel tubes surrounded byturbulator sections designed to ensure maximumheat transfer. The hot combustion gases from thevertical burner tubes pass horizontally across thechamber where they transfer high temperatureheat to the first inner circumference of smallertubes as the gases pass through them. The cooledgases then pass through the second outercircumference of larger tubes where the remaining‘dry’ and ‘wet – condensing’ heat is transferred.

TECHNICAL DATA SHEET

70501

CondensingBOILER

� 86%GCV to 99%GCV modulating efficiency range� Modulation 25% to 100%� Small foot print for easy access

SMOOTH AUSTENITICSTAINLESS STEEL TUBES

BURNER FLAME

TURBULATORS

PRE-MIXEDAIR & GAS

CROSS SECTION OF BURNER

CROSS SECTION OF HEAT EXCHANGERSBOILER CIRCUITRY

TURBULATORS

SMOOTH AUSTENITIC STAINLESSSTEEL TUBES

BOILER FLUEOUTLET

HEATINGRETURN

FLUE

GAS & AIR SUPPLY

MOTOR,FAN &VENTURI

HEATINGFLOW

Page 3: TECHNICAL DATA SHEET 70501

IN-BUILT FEATURES

� Austenitic stainless steel construction for total corrosion resistance� Unique fully pre-mix gas burner with ionisation flame sensor� Boiler controller with weather compensating operation with modulating burner control, compatible with BMS controls,

cascade master/slave boiler control available� Flow and return water temperature sensors� High limit boiler temperature thermostat� Syphon for condensate drain� Control Panel with ON/OFF switch, overheat limit thermostat,LCD display for programming & operational status� Levelling feet� Pump for cooling of burner to give low NOx performance

CONNECTIONS

DIMENSIONS mm

� 4 BARS or 6 BARS maximum working pressure� 85˚C maximum working temperature� NOx emissions less than 40 mg/m3

PERFORMANCESPECIFICATION

The boiler body ismade of 316Laustenitic stainlesssteel. The outer case ismade fromenamelled qualitysteel. The first andsecond heatexchangers are madeof smooth 316Laustenitic stainlesssteel tube withintegrated turbulators,The premix burner isunique and patented,with water cooling ofthe 316L austeniticstainless steelelements to ensure lowNOx performance.The control panelincorporates backlighted LCD display fordata settings andboiler informationdisplay, ON/OFFswitch, fuse housing,safety limit thermostat,space allocation forone or twoc a s c a d e / w e a t h e rcompensators (ifrequired) and theiroptions

NO SPECIAL

CIRCUITS ARE

REQUIRED WITH

THE M-SERIES

BOILER

Model 116 145 180 220 270 330 390 450Height 1561 1651 1726 1718 1867 1700 1845 1990Width 692 692 692 753 753 878 878 878Depth 875 875 875 915 915 1084 1084 1084Access controls front 500 500 500 500 500 500 500 500Access door one side 500 500 500 500 500 500 500 500Access door other side 500 500 500 500 500 500 500 500Access pipes/flue rear 500 500 500 500 500 500 500 500Access top (from floor) 1850 1950 2000 2350 2500 2350 2500 2500

Model 116 145 180 220 270 330 390 450Maximum output kW 122 155 192 240 294 349 415 472Minimum output kW 29 36 45 88 108 82 97 112Max working pressure BARS 4 4 4 6 6 6 6 6Gas supply pressure mBAR 17 to 25Gas used m3/Hr maximum 12.9 16.4 20.3 25.4 31.1 36.9 43.9 50.0

Electricity Watts 420 440 460 580 635 620 640 820Full load amps 8 8 8 10 10 10 10 12

Dry weight kg 220 230 235 340 370 440 475 525Water content litres 66 70 74 90 115 162 176 190Min water pressure BARS 1 1 1 1 1 1 1 1Max water pressure BARS 4 4 4 6 6 6 6 6Min flow rate l/sec 1.39 1.73 2.15 2.57 3.23 3.94 4.67 5.39Max flow rate l/sec 2.77 3.46 4.30 5.26 6.45 7.89 9.33 10.78

Friction to water flow based on Delta T of 20˚C kPA 34 42 54 39 56 37 46 59

Model 116 145 180 220 270 330 390 450Flue gas outlet 153 153 180 200 200 250 250 250Heating flow 50 50 50 65 65 80 80 80Heating return 50 50 50 65 65 80 80 80Drain outlet 25 25 25 25 25 32 32 32Condensate drain 25 25 25 32 32 32 32 32

Page 4: TECHNICAL DATA SHEET 70501

� Efficiency up to 99%GCV on 25% modulating output� Efficiency up to 92%GCV on 100% modulating output� Noise level averages 58 dBA on 25% load

Atlantic 2000 Box 11, Ashton Under Lyne, Lancashire, OL6 7TRTel: 0161 621 5960 or: 020 7237 4912 Fax: 0161 621 5966 E-mail: [email protected]: www.atlanticboilers.com

CALL ATLANTIC FOR FREE QUOTATION ALL PART OF THE SERVICE.... FREE DESIGN SERVICE

FREE COMPUTER GENERATED DIAGRAMS FREE EQUIPMENT SIZING AND SELECTION

FlueARRANGEMENTSThe ATLANTIC M Series boiler flue requirements are economic – oftencutting the material and labour costs when compared to other boilers.As the flue gas exit temperature is always low, the volume of gases isalways greatly reduced throughout the year.

When the comparatively smaller flues are manufactured from highgrade plastics, installations are fitted easily and have up to 20 yearguarantees. Care should be taken when joining multiples of boilersinto one stack to ensure the boiler flue gases are injected togetherrather than interrupting through-put.

Front view of Modulo Boiler Rear view of Modulo showing gassupply, flow and return heatingpipework and flue outlet

Modulo control panel

Outer casing opened for inspection

Inner casing opened for maintenance tomain and condensing exchangers