Page 1: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

MCCB

Moulded Case Circuit Breaker

T e c h n i c a l C a t a l o g u e

Page 2: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

general overview ... 2

feature

- company profile and certifications ... 6

MCCB

- NF series circuit breaker, double repulsion breaking method ... 11

- double number of copper contacts, materials of the NF series ... 12

- method of installation, MCCB cross sectional area,

positive indication & operation ... 13

- suitability for isolation, compliance with standards ... 14

- selection | quick & easy selection table ... 15

- power distribution | technical details ... 16

- characteristic curves | NF series ... 23

- physical dimensions & mounting holes | NF series ... 28

- accessories | phase insulation barriers,

electrical accessories & shunt trip ... 40

- accessories | under voltage device ... 41

- accessories | signal switches, rotary handle ... 42

- accessories | rotary handle ... 43

- accessories | mounting position ... 45

- internal resistance & power loss ... 46

- short circuit table | DC voltage ... 49

- selection table | motor circuit protection ... 50

- selection table | motor selection ... 51

- selection table | installation safety distance requirement ... 53

- selection table | terminal-tightening torque ... 54

- terminal-cable & copper busbar connection data ... 55

MCBs

- BHQ series | fixed type ... 56

- BHP series | plug-in type ... 57

- BHQ & BHP | operating characteristics & dimensions ... 58

notes ... 60

contents

Page 3: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

NF seriesThe NF series MCCBs are available from 50AF to 1200AF.

Pole sizes from 1 to 4 are available for the various models.

All NF series MCCBs are suitable for isolation.

250AF

NF250-GP NF250-MANF250-HA NF250-L

10kA (3P)25kA (1P to 4P)50kA (1P to 4P)65kA (3P)

50AF

NF50-MA

10kA (2P & 3P)

100AF

NF100-GP NF100-MANF100-HA NF100-L

10kA (2P & 3P)25kA (1P to 4P)50kA (1P to 4P)65kA (3P)

g e n e r a l o v e r v i e w

2

Page 4: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

400AF

NF400-GP NF400-LNF400-HA

25kA (3P & 4P)50kA (3P & 4P)65kA (3P)

600AF & 800AF

NF600-GP NF800-GPNF600-HA NF800-HANF600-L NF800-L

25kA (3P & 4P)50kA (3P & 4P)65kA (3P)

1200AF

NF1200-HA

50kA (3P & 4P)

3

Page 5: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

NF series

g e n e r a l o v e r v i e w

4

37-SDMS-01NF100-MA

37-SDMS-01NF250-MA

37-SDMS-01NF400-HA

37-SDMS-01NF600-HA

37-SDMS-01NF800-HA

Page 6: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

5

100AFBHP-16kA (1P)

100AFBHP-26kA (2P)

100AFBHP-36kA (3P)

100AFBHQ-16kA (1P)

100AFBHQ-26kA (2P)

100AFBHQ-36kA (3P)

MCB: BHQ & BHP series

37-SDMS-02NF400-HA

37-SDMS-03NF250-MA

Page 7: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

f e a t u r e

6

company profile

Since our inception in 1974, our company specializes in manufacturing low

voltage circuit breakers and have a reputation of producing products of

consistent quality and high reliability.

Our manufacturing facilities are certified to the international quality standards of

ISO 9001, while our products are certified by ASTA Certification Services UK and

SIRIM QAS International. With such high standards, our range of circuit breakers

are able to meet your highest demands for quality, safety and reliability.

Page 8: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

7

SIRIM QAS certification

Page 9: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

f e a t u r e

8

SIRIM QAS certification

Page 10: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

9

SIRIM QAS certification

Page 11: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

f e a t u r e

10

SASO certification

ICS = ICU 100%

Page 12: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

11

NF series circuit breakers

The demand for economical and high performance circuit

breakers is ever increasing in the global market. The NF

series circuit breakers provide a simple and reliable

solution to meet this global demand where quality,

performance and compliance are required.

The NF series circuit breakers have been engineered

to provide effective protection to low voltage power

distribution systems. The NF series is a complete range

of MCCB’s from 10A to 1200A with 1, 2, 3 and 4 pole

versions. An extensive range of electrical accessories is

also available.

double repulsion breaking method

The double repulsion method uses a

“reverse-loop” of current (I) flowing in

essentially opposite directions (see figure).

This creates a repulsion action and results

in a greater opening force (Fm) between

the fixed and moving contacts. This force

also assists to rapidly extinguish the arc,

thereby causing the moving contacts to

open faster. A faster breaking time is

achieved with this design.

moving contacts

fixed contact

Page 13: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

f e a t u r e

12

double number of contact coppers

For the NF600 and above circuit breakers,

double moving contacts are used instead

of a single contact. This additional moving

contact improves the short circuit breaking

performance and reduces contact wear.

materials of the NF series

The design of the NF series circuit breakers makes it

suitable to be used in hot and humid climates. The

material used for the circuit breaker casing

consists of synthetic resins reinforced with

glass fibers. Furthermore, the metal parts

used in the breakers are chemically treated

to protect against corrosion. The external

copper terminals are tin-plated to prevent

oxidation.

double moving contacts in NF1200

Page 14: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

13

method of installation

The NF series circuit breakers

can be installed in vertical or

horizontal position without any

impact on its performance or

de-rating of characteristics.

MCCB cross sectional area

positive indication & operation

horizontal vertical

The circuit breaker operating handle is designed to indicate the exact position of

its moving contacts. Its “trip-free” operating mechanism cannot indicate that the

breaker is ON if the moving contacts are in the OFF position. If the breaker trips

due to an electrical fault or overload the handle will be in between the ON and

OFF position. This is the TRIP position. To switch the breaker ON after tripping,

the handle position must be switched to OFF position first and so to reset the

breaker and then switch to the ON position.

BA

FD E

C

Parts Index for cross-sectional area of MCCBA – MCCB casing made of high-impact BMC material reinforced with

glass fibres, providing a safe and strong housing in the event ofbreaking high-fault currents.

B – Trip-free mechanism ensuring positive operation and isolationsuitability. Designed for long service life and high number ofoperating cycles. Metal parts in mechanism are chemically treated towithstand harsh tropical weather conditions.

C – Arc chutes with predefined steel plates arrangement, provide highbreaking capabilities.

D – Fixed and moving contacts utilizing the “reverse loop” currentmethod, creates a repulsion force thus rapidly extinguishing the arc.

E – Common trip mechanism to ensure breaking of all poles even whenthe fault occurs at a particular pole.

F – Trip release consists of thermal (bi-metal) and magnetic devicessuitable for use in AC or DC supply voltages.

Page 15: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

f e a t u r e

14

suitability for isolation

In compliance with IEC 60947-2 standard, NF series circuit breaker guarantees no

leakage currents and

over-voltage withstand

between the supply and

load terminals when its

moving contacts are in

the open position.

compliance with standards

The NF series circuit breakers have been designed to meet international standards,

complying with the following standards:

1. IEC 60947-2: International Electro 8. SEC Distributors: Saudi Electricity

Committee Standard Company, Distribution Materials

2. BSEN 60947-2: British Standard Specifications Prequalified Manufacturer

European Norm 9. SASO: Saudi Standards, Metrology &

3. JIS C 8201-2: Japan Industrial Standard Quality Organization

4. GB 14048-2: China Standard 10. Housing & Development Board, Singapore

5. CNS 14816-2: Taiwan Standard 11. Ministry of Electricity & Water, Kingdom

6. CE: Conformity European of Bahrain

7. SIRIM: Malaysia 12. Jabatan Perkhidmatan Elektrik Kementerian

Pembangunan, Negara Brunei Darussalam

test trip button isolation

Page 16: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

15

selection | quick & easy table65502510

NF50-MA

NF100-GP

NF100-MA NF100-LNF100-HA

NF100-GP

NF250-GP NF250-MA NF250-HA NF250-L

NF400-GP NF400-HA NF400-L

NF600-GP NF600-HA NF600-L

NF800-GP NF800-HA NF800-L

NF1200-HA

RatedCurrent

In (A)

10

15

20

30

40

50

60

75

80

100

125

150

160

175

200

225

250

250

300

350

400

500

600

700

800

1000

1200

Interrupting Capacity Icu (kA) Sym at 415 Vac

Page 17: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

Notes: - denotes available.

p o w e r d i s t r i b u t i o n

16

Rated Short CircuitBreaking Capacity: (kA)

Rated Service Short CircuitBreaking Capacity: I cs = % I cu

600V

DC

400V

500V

440V

415V

380V

230V

IEC 60947-2

technical details | electrical characteristics

NF100NF50

50AF 100AF

NF250

250AF

10 15 20

30 40 50

2 3

690

8

MA

5

7.5

10

10

10

15

25

5

100

7.5

10

15

25

5

A

3

20000

model Code

Ampere Frame (AF)

Rated Current: In (A)at Ambient Temp 50˚C

Number of Poles Available

Rated Insulation Voltage: U i(V)

Rated Impulse withstandVoltage: U imp (kV)

Rated Ultimate Short CircuitBreaking Capacity: I cu (kA)

10 15 20 30 40

50 60 75 80 100

1 2 3 4

690

8 8 8 8

GP MA HA L

5 10 10 35

7.5 15 40 50

10 25 50 65

10 25 50 65

10 25 50 65

15 30 60 100

25 50 85 125

5 10 20 40

100 100 100 100

690

8 8 8 8

GP MA HA L

5 10 10 35

7.5 15 40 50

10 25 50 65

10 25 50 65

10 25 50 65

15 30 60 100

25 50 85 125

5 10 20 40

100 100 100 100

7.5 10 30 50

10 22 50 65

15 30 50 100

25 50 85 125

7.5 10 30 50

10 22 50 65

15 30 50 100

25 50 85 125

5 10 20 40

A A A A

3 3 3 3

15000

125 150 160 175

200 225 250

3 4

5 10 20 40

A A A A

3 3 3 3

15000

690V

250V

Suitable for Isolation

Utilization Category

Pollution Degree

No. of Electrical Operations

440V

380V

220V

JIS C 8201-2(sym)

DC

250V

Page 18: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

17

Notes: - denotes available.

Rated Short CircuitBreaking Capacity: (kA)

Rated Service Short CircuitBreaking Capacity: I cs = % I cu

600V

DC

400V

500V

440V

415V

380V

230V

IEC 60947-2

technical details | electrical characteristics

NF600 & NF800NF400

400AF 800AF

NF1200

1200AF

1000 1200

3 4

690

8

HA

10

40

50

50

50

60

85

40

100

30

50

50

85

40

A

3

8000

model Code

Ampere Frame (AF)

Rated Current: In (A)at Ambient Temp 50˚C

Number of Poles Available

Rated Insulation Voltage: U i(V)

Rated Impulse withstandVoltage: U imp (kV)

Rated Ultimate Short CircuitBreaking Capacity: I cu (kA)

250 300

350 400

3 4

690

8 8 8

GP HA L

10 10 35

22 40 50

25 50 65

25 50 65

25 50 65

30 60 100

50 85 125

20 40 40

100 100 100

690

8 8 8

GP HA L

10 10 35

22 40 50

25 50 65

25 50 65

25 50 65

30 60 100

50 85 125

20 40 40

100 100 100

18 30 50

25 50 65

30 50 100

50 85 125

18 30 50

25 50 65

30 50 100

50 85 125

20 40 40

A A A

3 3 3

11000

500 600 & 700 800

3 4

20 40 40

A A A

3 3 3

11000

690V

250V

Suitable for Isolation

Utilization Category

Pollution Degree

No. of Electrical Operations

440V

380V

220V

JIS C 8201-2(sym)

DC

250V

Page 19: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

p o w e r d i s t r i b u t i o n

18

technical details

NF250-MANF100-MA

100AF 250AF

NF600-HA

600AF

NF400-HA

400AF

10 15 20 30 40

50 60 75 80 100

125 150 160 175

200 225 250

250 300

350 400500 630

3

750

8

3 33

750 750750

8 88

model Code

Ampere Frame (AF)

Rated Current: In (A)at Ambient Temp 55˚C

Number of Poles Available

Rated Insulation Voltage: U i(V)

Rated Impulse withstandVoltage: U imp (kV)

Rated Ultimate Short CircuitBreaking Capacity: I cu (kA)

37-SDMS-01

electrical characteristics

No. of Electrical Operations

Pollution Degree

Utilization Category

Suitable for Isolation

Notes: - denotes available.

Rated Service Short CircuitBreaking Capacity: I cs = % I cu

415V

220V

IEC 60947-225 50

50 85

100 100

A A

3 3

15000 11000

25 50

380V 30 6030 60

50 85

100

A

3

15000

100

A

3

11000

Page 20: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

Rated Current: In (A)at Ambient Temp 55˚C

19

NF250-MANF800-HA

800AF 250AF

NF400-HA

400AF

model Code

Ampere Frame (AF)

700 800

3

750

8

125 150 160 175

200 225 250

3

750

8

250 300

350 400

3

750

8

Number of Poles Available

Rated Insulation Voltage: U i(V)

Rated Impulse withstandVoltage: U imp (kV)

Rated Ultimate Short CircuitBreaking Capacity: I cu (kA)

37-SDMS-01 37-SDMS-03 37-SDMS-02

technical detailselectrical characteristics

Pollution Degree

No. of Electrical Operations

Notes: - denotes available.

415V

220V

50 50

85 85

25

380V 60 6030

50

Suitable for Isolation

Rated Service Short CircuitBreaking Capacity: I cs = % I cu

IEC 60947-2

100

A

3

11000

100

A

3

15000

100

A

3

11000

Utilization Category

Page 21: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

technical detailsmechanical characteristics & accessories

p o w e r d i s t r i b u t i o n

20

90 140

30 44

156 257

210 390

132 194

86 104

103 134

stirrup saddle

20000 20000

1.5 6.5

-

- -

-

- -

105

35

166

210

126

104

123

stirrup

20000

2.4

-

-

-

-

210

70

275

500

243

104

155

saddle

20000

9.5

-

-

a

b*

aa

c

ca

bbb

bb

Wid

thLe

ngth

Dep

thAc

cess

orie

s

Type of Terminals

No of Mechanical Operations

Weight (kg)Operating Handle

LockTerminal Covers

Mounting ScrewsPhase Barrier

Cable LugTerminal Shrouds

With

out T

erm

inal

Cov

er b

(mm)

bb

C

ccaa

aa

ON

OFF100 LOCKED

UNLOCKED

L

CL CL^

NF250-MANF100-MA NF600-HANF400-HAmodel Code

37-SDMS-01

210 140

70 44

275 257

500 277

243 194

104 104

155 134

saddle saddle

20000 20000

10.5 5.5

-

-

-

-

105

35

166

177

126

104

123

stirrup

20000

2.2

-

-

-

-

a

b*

aa

c

ca

bbb

bb

Wid

thLe

ngth

Dep

thAc

cess

orie

s

Type of Terminals

No of Mechanical Operations

Weight (kg)Operating Handle

LockTerminal Covers

Mounting ScrewsPhase Barrier

Cable LugTerminal Shrouds

With

out T

erm

inal

Cov

er b

(mm)

bb

C

ccaa

aa

ON

OFF100 LOCKED

UNLOCKED

L

CL CL^

model CodeNF250-MANF800-HA NF400-HA

37-SDMS-01 37-SDMS-03 37-SDMS-02

* without Terminal Cover; ^ with Terminal Cover.

Notes: - denotes available.

Page 22: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

21

mechanical characteristics

technical details

NF100NF50

50AF 100AF

NF250

250AF

model Code

Ampere Frame (AF)

Fixed thermal, Fixed Magnetic 10 x Ith

Fixed thermal, Adjustable Magnetic

thermomagnetic trip release

MARated Ultimate Short Circuit

Breaking Capacity: I cu (kA) GP MA HA L GP MA HA L

1 2 3 42 3

50 75

130 130

60 60

77 77

110 110

– 25

42 60 90 120

155 155 155 155

68 68 68(80) 68

90 90 90(102) 90

132 132 132 132

– – 30 30

1 3 4

48 105 140

165 165 165

68 68(80) 68

92 92(104) 92

126 126 126

35 35 35

M5 clampterminal screw

20000

Number of Poles (P)

Type of Terminals

No of Mechanical Operations

M8 screw

20000

M8 screw

20000

0.4 0.5Weight (kg) 0.5 0.7 1.0(1.2) 1.4 0.7 1.5(1.6) 1.9

Shunt Trip Device

Under Voltage Trip Device

Auxiliary Switch

Alarm Switch

Auxiliary + Alarm Switch

Rotary Handle

accessories

Notes: All L-type breakers are only available in the 3-pole version; ( ) denotes for L-type.

- denotes available; however, all accessories are not available for 1-pole models.

aa

a

b

c

ca

bb

Page 23: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

p o w e r d i s t r i b u t i o n

22

mechanical characteristics

technical details

NF600 & NF800NF400

400AF 800AF

NF1200

1200AF

model Code

Ampere Frame (AF)

Fixed thermal, Fixed Magnetic 10 x Ith

Fixed thermal, Adjustable Magnetic

thermomagnetic trip release

GP HA LRated Ultimate Short CircuitBreaking Capacity: I imp (kA) GP HA L HA

Shunt Trip Device

Under Voltage Trip Device

Auxiliary Switch

Alarm Switch

Auxiliary + Alarm Switch

Rotary Handle

accessories

Notes: All L-type breakers are only available in the 3-pole version; ( ) denotes for L-type.

- denotes available.

20000No of Mechanical Operations 20000 20000

5.5(6.0) 7.2Weight (kg) 10.0(11) 12.0 15.0 19.0

3 43 4

140 196

257 257

103 103

155 155

194 194

44 44

210 280

275 275

103 103

155 155

243 243

70 70

3 4

210 280

406 406

140 140

250 250

375 375

70 70

M12 Bolt

Number of Poles (P)

Type of Terminals M12 Bolt M12 Bolt

aa

a

b

c

ca

bb

Page 24: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

23

c h a r a c t e r i s t i c s

tripping curve temperature characteristic

tripping curve temperature characteristic

NF50-MA | characteristic curves

145

140

135

130

125

120

115

110

105

100

9510 15 20 25 30 35 40 45 50 55 60

Rate

d am

bien

t

40~50A

10A~30A

Instantaneous trip

NF100-GP, MA & HA | characteristic curves

Page 25: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

c h a r a c t e r i s t i c s

24

NF250-GP, MA & HA | characteristic curves

NF400-GP & HA | characteristic curves

130

120

110

100

90

10 20 30 40 50 60 7080

Rated ambient 50°C

Curr

ent r

atin

g (%

)Ambient temperature (°C)

Rate

d am

bien

t

tripping curve temperature characteristic

tripping curve temperature characteristic

Page 26: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

25

NF600/800-GP & HA | characteristic curves

NF1200-HA | characteristic curves

Frame size: 800AF

NF600

NF800

tripping curve temperature characteristic

tripping curve temperature characteristic

Page 27: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

c h a r a c t e r i s t i c s

26

NF100-L | characteristic curves

NF250-L | characteristic curves

tripping curve

tripping curve

Page 28: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

27

NF400-L | characteristic curves

NF600/800-L | characteristic curves

tripping curve

tripping curve

Page 29: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

p h y s i c a l d i m e n s i o n s & m o u n t i n g h o l e s

28

NF50-MA | front connection

2-pole 3-pole

2-pole 3-pole

Page 30: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

29

NF100-GP, MA & HA | front connection

2-pole 3-pole

2-pole 3-pole

4-pole

4-pole

Page 31: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

p h y s i c a l d i m e n s i o n s & m o u n t i n g h o l e s

30

NF250-GP, MA & HA | front connection

3-pole

3-pole

4-pole

4-pole

Page 32: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

31

NF400-GP & HA | front connection

3-pole 4-pole

3-pole

4-pole

Page 33: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

p h y s i c a l d i m e n s i o n s & m o u n t i n g h o l e s

32

NF600/800-GP & HA | front connection

3-pole 4-pole

3-pole

4-pole

Page 34: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

33

NF1200-HA | front connection

Insulation barrier(removable)

Insulation barrier(removable) Bolt

M12x50

ConductorMountinghold

Mountinghold11

540

6

406

346

95

18.5

15

17

50

133.5140

190

250

346

95

78

43

8

15

328

15

32

140

210

70210

280

80

13 13

N NeutralPole

375

70 70

97

803 Pole

4 Pole

R11.5

M8 Screwor 10mm

3-pole 4-pole

Page 35: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

p h y s i c a l d i m e n s i o n s & m o u n t i n g h o l e s

34

NF100-L | front connection

NF250-L | front connection

3-pole

3-pole

3-pole

3-pole

Page 36: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

35

NF400-L | front connection

NF600/800-L | front connection

3-pole

3-pole

3-pole

3-pole

Page 37: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

p h y s i c a l d i m e n s i o n s & m o u n t i n g h o l e s

36

37-SDMS-01NF100-MA | front connection

37-SDMS-01NF250-MA | front connection

103906030

22

15

61

32

50

.2

908683

30 M4x0.7 threador 5 mm-dia. hold

Breaker

13

2

OFF100

UNLOCKED

LOCKED

ON

CL CL CL

CLCL

Ø 4

.5

Ø 8

.5

M4x0.7 threador 5 mmdia. hold

CL

CL CL

CL

1057035

99

24.5

104107.5123

12

6

16

6

10

25

0

UNLOCKEDON

OFF200 LOCKED 1

26

35

Breaker

Ø 4.5

Ø 7

Page 38: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

37

37-SDMS-01NF400-HA | front connection

37-SDMS-01NF600-HA | front connection

UNLOCKED

400 LOCKED

OFF

Mountinghold

OFF

ON

162140

63.4 63.4

25

7

10

2.2

90

.4

39

.5

43

19

431

.59

0.4CL

CL

CL

958 37

44

19

4

47

97.5104113134

M10 Hex.head Screw

M6 Screw or7mm dia. hold

M20 SocketSet Screw

CL

CL

Breaker

Ø 7Ø 12.5

70M6 Screw or7mm dia. hold

Breaker

CL

CL

24

3UNLOCKED

LOCKED630

OFF

OFF

ON

102

27

5 (M

ax. w

itho

ut c

over

)

210mm (Max.)

5

155mm (Max.)1071049794.5

82

10

2

Ø 8

Ø 14

15±0.2

Ø 4

500A: t= 6 m/m630A: t= 8 m/m800A: t= 12 m/m

t

CL

CL CL

Page 39: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

p h y s i c a l d i m e n s i o n s & m o u n t i n g h o l e s

38

37-SDMS-01NF800-HA | front connection

70M6 Screw or7mm dia. hold

Breaker

CL

CL

24

3UNLOCKED

LOCKED800

OFF

OFF

ON

102

27

5 (M

ax.

wit

hout

cov

er)

210mm (Max.)

5

155mm (Max.)1071049794.5

82

10

2

Ø 8

Ø 14

15±0.2

Ø 4

500A: t= 6 m/m630A: t= 8 m/m800A: t= 12 m/m

t

CL

CL CL

Page 40: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

39

37-SDMS-02NF400-HA | front connection

Ø 12.5 Ø 7

134

44

19

4

14087

43.5

25

7

10

2.2

90

.43

9.5

19

431

.59

0.4

11310497.595

47

CL CL

CLCL

CL

Breaker

Mountinghold

M6 Screw or7mm dia. hold

M10 Hex. head screw

400

OFF

ON

OFF

Terminal Shroud

Terminal Shroud

Phase Barrier

37-SDMS-03NF250-MA | front connection

105

35

16

6

10

2

12310710499

50

70

12

6CL

CL

CL200

OFF

ON

Ø 7

Ø 4.5

24.5M8 Hex. socket

head screwTerminal Shroud

Terminal Shroud

Phase Barrier

M8 Hex. sockethead screw

M4x0.7 threador 5 mm-dia. hold

Breaker

35

CL

12

6

Page 41: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

a c c e s s o r i e s

40

phase insulation barriers

Inter phase barriers are provided as standard. The use

of the inter phase barriers is

necessary to increase the

clearance distances between

phases to prevent electrical

faults during the operation

of the circuit breaker.

electrical accessories & shunt trip

All electrical accessories supplied for the breaker are pre-

wired. Accessories such as Shunt Trip, Under Voltage Trip,

Alarm Switch, Auxiliary Switch and combination Alarm and

Auxiliary Switch can be fitted into the breaker accessory

compartments. Please refer to the table in page 31 for the

accessories installation guide.

Shunt Trip Device

The Shunt Trip device opens the circuit breaker by means

of an electrical signal. Voltages between 70% and 110% of

the coil voltage rating will operate the shunt trip device.

All Shunt Trip devices are factory fitted with a cut-off

supply switch.

baModel

NF50 59 59

NF100 59 59

NF250 62 100

NF400 95 116

NF600 95 116

NF800 top95 116

NF1200 95 116

a

bdimensions of phase

barrier insulators in mm

Page 42: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

41

< 15 < 15 < 15 8 to 15 8 to 15 8 to 15

under voltage trip device

The Under Voltage Trip device will open the circuit breaker contacts when the supply

voltage to the coil drops below 70% of its voltage rating.

After tripping, the circuit breaker can be closed manually

again when the supply voltage is 85% of its coil voltage

rating or more.

The Under Voltage Trip device is always energized during

normal conditions when supply voltage is healthy.

NF1200NF600NF400NF250NF100NF50

Coil Power Consumption (VA)50 / 60 Hz

Coil Voltage

200 200120 20 (100V)

50 (200V)

120 120

200 200

200 200

120 (330V)

170 (450V)

200

10

8 to 15

NF800

200

200

200

200

10 70

120

10

120 120

50

AC 110 - 240

AC 100 - 450

AC 200 - 240

AC 380 - 450

AC 380 - 550

DC 100 - 125

AC Coil Voltage Consump (VA) Trip Time (ms)Model

5 < 30

5 5 to 30

380-415 440-480

400-440

100-110 200-220

100-110 200-220

5 5 to 30

5 6 to 35

400-440

380-450

100-110 200-220

100-120 200-240

NF250 & below

NF400

NF800

NF1200

Trip Time (ms)

Note: Other voltages can be supplied on demand.

Page 43: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

a c c e s s o r i e s

42

signaling switches

The Signaling switches allow the breaker

status information to be obtained remotely.

The signaling switch consists of several dry

contacts with both normally open (N.O.) and

normally closed (N.C.) positions.

Auxiliary Switch - Provides breaker ON and

OFF status information.

Alarm Switch - Provides breaker TRIP status

information.

Auxiliary + Alarm Switch - Provides breaker

ON, OFF and TRIP status information.

rotary handle | mechanism

The breaker mounted rotary handle mechanism allows the user to easily switch the

breaker ON by a rotating action.

The rotary handle mechanism is equipped with a safety device that prevents the

panel door from being open when the breaker is in ON position. A bypass screw is

provided for manual intervention when breaker is in ON position.

Pad locking facility is available on the rotary handle. The handle can be pad locked

when the breaker is in OFF position.

Please refer to the abovecircuit diagram for the switchterminal codes in order toobtain different contactpositions, such as N.O. andN.C. to suit the application.

Auxiliary Switch

Alarm Switch

Page 44: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

43

Drilling Plan

ExternalDimensions

Figure Dimensions (mm) MountingScrewsType Breaker Type

Noof

Pole

a

b

c

d

e

e

A B C D

95

105

117

107

119

183

25

30

44

70

111

132

(116)

35126

(145)

194

243

M4 x 0.7

screw

or ø 5

M6

screw

or ø 7

(X)

breakers

mounting

screws (2pcs)

(Y) operating

handle

mounting

screws (2pcs)

(X) (Y)

breakers

mounting

screws (4pcs)

AC-NF-RHN0

AC-NF-RHN1

AC-NF-RHN2

AC-NF-RHN3

AC-NF-RHN4

NF50-MA

NF100-GP MA HA

NF100-L

EG100-MA HA

NF250-GP MA HA

NF250-L

EG250-MA HA

NF400-GP HA L

NF600-GP HA L

NF800-GP HA L

NF1200-HA

3P

3P

4P

3P

4P

3P 4P

3P

4P

rotary handle | external dimensions

rotary handle | drilling plan

Figure (a)

Figure (c) Figure (d) Figure (e)

Note All rotary handles are supplied with M4 x 0.7 screws and self-tapping ø 5mm screws.

Figure (b)

Page 45: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

a c c e s s o r i e s

44

rotary handle | appearance

A direct rotating operating handle has a standard safety device which prevents the

breaker from closing as long as the cover is open. It indicates the tripping of the

breaker even in ON-lock position, but only in cases when a single padlock (35mm)

is used. The degree of protection, in accordance with IEC529, is IP3X (or IP5X with

provision of dustproof packing).

The use of therotary handlemechanismincreases the IPrating of the breaker

The figure above shows the relationshipbetween the hinge and breaker viewedfrom the load side of the breaker.

Left hingeX1

Left hingeH

Center of hinge & BreakerType

0 or more(5H + 100)

or more

0 or more(8H + 100)

or more

Right hingeX2

Right hingeH

Less than 10

10 or more

170 or more

(5H + 120) or more

0 or more (4H + 70) or more

AC-NF-RHN0 to

AC-NF-RHN2

AC-NF-RHN3 to

AC-NF-RHN4

Page 46: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

45

mounting position | internal accessory

NF1200HA

NF600/800GP HA L

NF400GP HA L

NF250GP MA HA L

NF100GP MA HA L

NF50MA

MCCB modelsAccessories

R1 & 2 R1 & 2

R1 & 2 R1 & 2

R1 & 2 R1 & 2

R1 & 2 R1 & 2

– R1 & 2

– R1 & 2

L1, L2, L3 L1, L2, L3

L1, L2, L3 L1, L2, L3

L1, L2, L3 L1, L2, L3

L1 & L2 L1, L2

L1 & L2 L1, L2

L1 & L2 L1, L2

L1 & L2

L1 & L2

– L1 & L2

Shunt Trip Coil

(STC)

Under VoltageTrip (UVT)

Auxiliary Switch(AUS)

Alarm Switch(ALS)

Auxiliary +Alarm Switch

(AAS)

Notes

1) It is NOT possible to install both UVT and STC in the same MCCB.

2) For NF600 onwards, it is possible to install up to a maximum of 4 Auxiliary. Switches or 2 Alarm switches.

3) UVT requires a voltage module that is installed on the right side lead wire terminal.

L = Left compartment; R = Right Compartment

Accessory compartment slot markings

right side

left side

Page 47: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

r e s i s t a n c e & p o w e r t a b l e

46

NF250-MA

LossW

ResistanceuΩ

NF100-MA

LossW

ResistanceuΩ

8700

6200

3570

1980

1480

1.6 7200 0.7

2.0 6700 1.5

2.5 6000 2.4

3.2 3100 2.8

3.4 1990 3.1

3.7 1480

1200

1100

980

770

3.7

4.3

6.2

6.5

7.7

575 9.0

11.8

12.1

14.6

16.9

525

395

365

335

NF800-GP

internal resistance & power lossLossW

ResistanceuΩ

NF600-GP

LossW

ResistanceuΩ

NF400-GP

LossW

ResistanceuΩ

NF250-GP

LossW

ResistanceuΩ

NF100-GP

LossW

ResistanceuΩ

NF50-MA

ResistanceuΩ

LossW

Type

In A

10A 60000 6.0

58000 1.3

45000 1.8

32000 2.9

19000 3.0

1650

1175

1120

1010

820

4.1

4.2

6.3

7.1

8.2

450 7.0

9.0

10.7

12.4

13.2

196 12.3

162 14.6

148 18.1

120 19.2

100

90

25.0

32.4

70

60

34.3

38.4

400

350

310

260

15A

20A

30A

40A

50A

60A

75A

80A

100A

125A

150A

10.94259.7380160A

175A

200A

225A

250A

300A

350A

400A

500A

600A

700A

800A

15600

Page 48: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

47

NF1200-HA

internal resistance & power lossLoss

WResistance

NF800-HALoss

WResistance

NF600-HALoss

WResistance

NF400-HALoss

WResistance

NF250-HALoss

WResistance

NF100-HALoss

WResistance

Type

In A

31500

33500

17000

8500

6000

3300

3.2

7.5

6.8

7.7

9.6

8.2

2000 7.2

1500

1200

8.4

8.8

950 9.5

775 12.1

725 16.3

595 18.1

575 23.0

535 27.0

251 15.7

188 16.9

188 23.0

138 22.1

220 51.0

210 75.6

120 58.8

105 67.2

55 55.0

45 64.8

10A

15A

20A

30A

40A

50A

60A

75A

80A

100A

125A

150A

160A

175A

200A

225A

250A

300A

350A

400A

500A

600A

700A

800A

1000A

1200A

680 17.4

Page 49: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

r e s i s t a n c e & p o w e r t a b l e

48

internal resistance & power lossNF800-L

LossW

ResistanceuΩ

NF600-LLoss

WResistance

NF400-LLoss

WResistance

NF250-LLoss

WResistance

NF100-LLoss

WResistance

Type

In A

31500

33500

17500

9000

7000

4500

3.2

7.5

7.0

8.1

11.2

11.3

2200 7.9

1800

1500

10.1

11.2

1350 13.5

775 12.1

725 16.3

595 18.1

575 23.0

535 27.0

290 18.1

195 17.5

185 22.7

175 28.0

220 51.0

210 75.6

120 58.8

105 67.2

10A

15A

20A

30A

40A

50A

60A

75A

80A

100A

125A

150A

680 17.4160A

175A

200A

225A

250A

300A

350A

400A

500A

600A

700A

800A

Page 50: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

49

DC voltage | time constant 10ms or below

d c s h o r t c i r c u i t t a b l e

Model Pole 48V Icu/Ics 125V Icu/Ics 250V Icu/Ics 400V Icu/Ics 550V Icu/Ics 600V Icu/Ics

NF50-MA2

3

40 / 20

40 / 20

41 / 20

42 / 20

40 / 20

NF100-GP

1

2

3

NF100-MA

NF100-HA

NF100-L

NF250-GP

NF250-MA

NF250-HA

1

2

3

4

1

2

3

4

3

1

2

3

4

1

2

3

4

3

1

2

3

NF250-L

NF400-GP

NF400-HA

NF400-L

NF600 /

NF800-GP

NF600 /

NF800-HA

NF800-L

NF1200-HA

3

4

3

4

3

3

4

3

4

3

3

4

50 / 25

50 / 25

50 / 25

50 / 25

100 / 50

100 / 50

100 / 50

100 / 50

150 / 75

50 / 25

50 / 25

50 / 25

50 / 25

100 / 50

100 / 50

100 / 50

100 / 50

150 / 75

40 / 20

40 / 20

40 / 20

80 / 40

80 / 40

100 / 50

100 / 50

150 / 75

80 / 40

80 / 40

100 / 50

100 / 50

150 / 75

100 / 50

100 / 50

15 / 8

15 / 8

15 / 8

15 / 8

15 / 8

30 / 15

30 / 15

30 / 15

30 / 15

80 / 40

80 / 40

80 / 40

80 / 40

100 / 50

30 / 15

30 / 15

30 / 15

30 / 15

80 / 40

80 / 40

80 / 40

80 / 40

100 / 50

15 / 8

15 / 8

15 / 8

40 / 20

40 / 20

80 / 40

80 / 40

100 / 50

40 / 20

40 / 20

80 / 40

80 / 40

100 / 50

80 / 40

80 / 40

7.5 / 4

7.5 / 4

7.5 / 5

7.5 / 6

7.5 / 7

15 / 8

15 / 8

15 / 8

15 / 8

40 / 20

40 / 20

40 / 20

40 / 20

50 / 25

15 / 8

15 / 8

15 / 8

15 / 8

40 / 20

40 / 20

40 / 20

40 / 20

50 / 25

7.5 / 4

7.5 / 4

7.5 / 4

20 / 10

20 / 10

40 / 20

40 / 20

50 / 25

20 / 10

20 / 10

40 / 20

40 / 20

50 / 25

40 / 20

40 / 20

6 / 3

6 / 3

10 / 5

10 / 5

25 / 13

25 / 13

35 / 18

10 / 5

10 / 5

25 / 13

25 / 13

35 / 18

6 / 3

13 / 8

13 / 8

25 / 13

25 / 13

35 / 18

13 / 8

13 / 8

25 / 13

25 / 13

35 / 18

25 / 13

25 / 13

8 / 4

18 / 9

8 / 4

18 / 9

10 / 5

18 / 9

10 / 5

18 / 9

18 / 9

8 / 4

18 / 9

8 / 4

18 / 9

10 / 5

18 / 9

10 / 5

18 / 9

18 / 9

Page 51: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

s e l e c t i o n t a b l e

50

Interrupting Capacity Icu (kA) Sym

motor circuit protection 65

NF100-L

NF250-L

NF400-L

NF800-L

50

NF100-HA

NF250-HA

NF400-GP NF400-HA

NF600-HA

NF800-HA

25

NF100-MA

NF250-MA

10

NF50-MA

NF100-GP

NF250-GP

NF600-GP

NF800-GP

MotorCapacity

[kW at 400/440]

Motor Full-load

Current [A]

MCCB In [A]

0.37

0.55

0.75

1.1

1.5

2.2

3

4

5.5

7.5

11

15

18.5

22

30

37

45

55

75

90

110

132

160

200

250

290

315

355

1.1

1.5

1.9

2.8

3.5

5

6.6

8.6

11.5

15

22

29

36

42

56

68

83

98

135

158

193

232

282

349

430

520

545

610

10

10

10

10

10

10

15

15

20

30

40

40

50

60

75

100

125

150

200

225

250

300

350

400

600

700

700

800

3-phase motor | 400V 440V 50 / 60Hz

Page 52: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

51

Motor Full-Load Current (A)

3 ø 415VRated Current (A)

Wire Size (mm2)

Rated Current (A)

Wire Size (mm2)

Wire Size (mm2)

Rated Current (A)

Motor Full-Load Current (A)

3 ø 220V

motor selection | direct-online-starter

1.1 2.1

10

2

0.65

10

2

0.58

10

2

10

2

1.2

10

2

1.1

10

2.4 3.3 4.4 5.9 8.4 11 13.6 2015.5

10

2

1.4

10

2

1.3

10

10 10 15 20 30 30 5030

2 2 2 2 2 5.5 5.55.5

1.9 2.5 3.4 4.8 6.4 7.9 11.59

10 10 10 10 15 15 20 30

2 2 2 2 2 2 5.55.5

1.8 2.4 3.2 4.5 5.9 7.3 10.57.7

10 10 10 10 15 15 2015

2 2 2 2 2 2 2 2 5.52

MotorRatings

5.543.732.21.51.10.750.550.370.18kW

HP 1/4 1/2 3/4 1 1.5 2 3 4 5 5.5 7.5

Motor Full-Load Current (A)

3 ø 380V

Motor Full-Load Current (A)

3 ø 415VRated Current (A)

Wire Size (mm2)

Rated Current (A)

Wire Size (mm2)

Wire Size (mm2)

Rated Current (A)

Motor Full-Load Current (A)

3 ø 220V

26.5 38

60

14

15

30

5.5

14

30

5.5

75

22

22

50

8

20.5

50

50 61

100

38

29

60

14

27

60

100

38

36

75

22

33

75

8 14 22

71 97

125

60

41

100

38

38

75

150

60

56

100

38

52

100

22 38

120 145

175

80

70

150

60

65

125

200

100

84

125

60

77

125

60 60

180 240

225

125

104

150

80

95

150

400

200

143

200

100

130

175

80

290

500

200

170

225

125

154

200

100100

MotorRatings

9075554537302218.515117.5kW

HP 10 15 20 25 30 40 50 60 75 100 125

Motor Full-Load Current (A)

3 ø 380V

Short Circuit protection of electric motors

The NF series circuit breakers are suitable to combine with motor starters. As defined in IEC 60947-4

standards, the starter switching device, usually a magnetic contactor, must be coordinated with the

equipment capable of providing short circuit protection for circuit wiring/cables.

The common starting methods for asynchronous squirrel-cage induction motors which the NF series can be

used in combination are the direct-online-starters and star-delta-starters.

The following selection tables, illustrating the above, shows the suitable breaker ratings that can

accommodate motor starting currents. When more than one motor is connected to a branch circuit, the

sum of the motor rated current equals to the rated current of the breaker.

Please note that the breaker selection shown in the tables are subjected to the following: only 1 motor to be installed in the circuit andthe starting current is less than 6 times of motor full load current.

Page 53: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

s e l e c t i o n t a b l e

52

Motor Full-Load Current (A)

3 ø 380V

Motor Full-Load Current (A)

3 ø 415V

Rated Current (A)

Wire Size (mm2)

Rated Current (A)

Wire Size (mm2)

Wire Size (mm2)

Rated Current (A)

Motor Full-Load Current (A)

3 ø 220V

motor selection | direct-online-starter

motor selection | star-delta-starter

349 411

600

200

202

400

150

185

300

150

700

325

238

400

200

218

400

500 625 780 980

800

325

290

500

200

260

500

360 450 570

600 800 1000

200 325 325

330 415 520

600 700 800

200 200 200 325 325

MotorRatings

315250200160132110kW

HP 150 180 220 270 340 420

Motor Full-Load Current (A)

3 ø 415V

Rated Current (A)

Wire Size (mm2)

Rated Current (A)

Wire Size (mm2)

Wire Size (mm2)

Rated Current (A)

Motor Full-Load Current (A)

3 ø 220V

20 28.5

50

8

11.5

30

3.5

10.5

30

3.5

50

8

15

30

5.5

14

30

5.5

38 50

75

22

22

50

8

20.5

50

8

100

22

29

60

14

27

60

14

61 71

125

38

35

75

22

33

75

22

150

38

41

100

38

41

100

22

97 120

200

60

56

100

38

52

100

38

225

60

70

150

50

65

150

50

145 180

300

80

84

175

50

77

175

50

240

400

100

143

225

80

130

225

80

400

80

104

225

60

95

200

60

MotorRatings

75554537302218.515117.55.5kW

HP 7.5 10 15 20 25 30 40 50 60 75 100

Motor Full-Load Current (A)

3 ø 380V

Please note that the breaker selection shown in the tables are subjected to the following: only 1 motor to be installed in the circuit andthe starting current is less than 6 times of motor full load current.

Page 54: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

53

110

Motor Full-Load Current (A)

3 ø 415VRated Current (A)

Wire Size (mm2)

Rated Current (A)

Wire Size (mm2)

Wire Size (mm2)

Rated Current (A)

Motor Full-Load Current (A)

3 ø 220V

motor selection | star-delta-starter

290

500

150

170

300

100

154

300

80

MotorRatings

90kW

HP 125

Motor Full-Load Current (A)

3 ø 380V

349

600

150

202

400

125

185

300

100

150

160

411

800

200

238

400

125

218

400

125

132

180

500

1000

250

290

600

150

260

400

150

220

NF50

NF100-250

NF400-600

NF800-1200

Insulation, Insulated Barsor Painted Sheetmetal (mm)

installation | safety distance requirements

OperatingVoltageModel

25

50

75

80

A40

50

50

55

100

100

B140

50

50

55

100

100

B2

Bare/UnpaintedSheetmetal (mm)

25

30

80

90

A

45

55

100

100

B1

45

55

100

100

B2U<440V

U<600V

U<440V

U<600V

U<440V

U<600V

U<440V

U<600V

Please note that the breaker selection shown in the tables are subjected to the following: only 1 motor to beinstalled in the circuit and the starting current is less than 6 times of motor full load current.

Page 55: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

s e l e c t i o n t a b l e

54

NF800

NF50

NF100

NF250

NF400

NF600

NF1200

NF50

NF100

NF250

NF400

NF600

NF800

NF1200

tightening range* Nm Bolt/Screw

To ensure the correct operation of the MCCB, it is essential to make a proper

cable or busbar termination to the MCCB. It is recommended that the

supplied screws be used to connect the cables or busbars to the breaker

terminals and tightened to the torque, as shown in the table below.

terminal-tightening torque

Cable size mm2 ScrewModel

terminals for cable lugs connection

M5 screw Pan head

M8 screw Screw

1.8 ~ 2.0 N/A

2.5 ~ 3.5 N/A

1.6 ø

Min Max I II Size Type

22

1.6 ø 50

M8 screw Screw

M12 bolt x 2 Bolts

2.5 ~ 3.5 N/A

N/A 10 ~ 14

38 150

150 2 x 100

M12 bolt x 2 Bolts

N/A N/A

N/A 10 ~ 14

N/A N/A

2 x 150 2 x 200

N/A N/A

N/A N/AN/A N/AN/A N/A

tightening range* kgf-cm Bolt/ScrewCopper busbar size mm2

Model

terminals for copper busbar connection

M5 screw

M8 screw

1.8 ~ 2.0 N/A

2.5 ~ 3.5 N/A

5

Max t = Max w = I II Size

12.5

5 16.5

M8 screw

M12 bolt x 2

2.5 ~ 3.5 N/A

N/A 10 ~ 14

7 23

8 25

M12 bolt x 2

M12 bolt x 2

N/A 10 ~ 14

N/A 10 ~ 14

8 40

10 44

M12 bolt x 2N/A 10 ~ 1417 44

* NoteCopper busbar

Caution1) Do not over tighten. If the tightening torque is

exceeded, bolts/screws and copper bars may be damaged.

2) Failure to secure a terminal connection maycause an electrical fault. Make sure allterminal connections are tightly secured.

Page 56: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

55

terminal-cable & copper busbar sizes

c o n n e c t i o n d a t a

ISO Square(mm2)

CNS StandardSquare (mm2)

UL StandardAWG or kcmil at 75˚C

MCCBRated Current

In (A)

8 ≥ In > 0 1 1.2 ø 14 AWG

14 AWG

14 AWG

12 AWG

10 AWG

10 AWG

8 AWG

6 AWG

4 AWG

3 AWG

2 AWG

1 AWG

1/0 AWG

2/0 AWG

3/0 AWG

4/0 AWG

250 MCM

300 MCM

350 MCM

500 MCM

2 x 3/0 AWG

2 x 250 MCM

2 x 350 MCM

3 x 300 MCM

2 x 250 MCM

2 x 350 MCM

3 x 300 MCM

1.6 ø

1.6 ø

2.0 ø

5.5

8

14

14

22

38

50

50

60

80

100

125

125

150

200

250

2 x 100

1.5

2.5

2.5

4

6

10

16

25

35

35

50

50

70

95

95

120

150

185

185

240

2 x 150

2 x 185

2 x 240

2 x (30 x 5)

2 x (40 x 5)

2 x (50 x 5)

2 x 150

2 x 200

2 x 250

2 x (30 x 5)

2 x (40 x 5)

2 x (50 x 5)

12 ≥ In > 8

15 ≥ In > 12

20 ≥ In > 15

25 ≥ In > 20

32 ≥ In > 25

50 ≥ In > 32

65 ≥ In > 50

85 ≥ In > 65

100 ≥ In > 85

115 ≥ In > 100

130 ≥ In > 115

150 ≥ In > 130

175 ≥ In > 150

200 ≥ In > 175

225 ≥ In > 200

250 ≥ In > 225

275 ≥ In > 250

300 ≥ In > 275

350 ≥ In > 300

400 ≥ In > 350

500 ≥ In > 400

630 ≥ In > 500

800 ≥ In > 630

500 ≥ In > 400

630 ≥ In > 500

800 ≥ In > 630

Page 57: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

M C B

56

BHQ series | fixed type100100100

BHQ-1 BHQ-2 BHQ-3

1

240 / 415 240 / 415 240 / 415

10 15 20 30 40

50 60 75 80 100

10 15 20 30 40

50 60 75 80 100

10 15 20 30 40

50 60 75 80 100

2 3

Ampere Frame (AF)

Model Code

Number of Pole (P)

Rated Voltage: Ue Vac

Rated Current: In (A)at Ambient Temperature: 50˚ C

6 / 6 6 / 6 6 / 6

25

95

50

95

75

95

58.5 58.5 58.5

77.5 77.5 77.5

100 100 100

0 25 50

0.15 0.31 0.46

Rated Ultimate Short CircuitBreaking Capacity: I cu (kA)

240V/415V

a

b

c

ca

bb

aa

kgWeight

IEC 60947-2

Page 58: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

57

BHP series | plug-in type100100100

BHP-1 BHP-2 BHP-3

1

240 / 415 240 / 415 240 / 415

6 / 6 6 / 6 6 / 6

25

74

50

74

75

74

60.5 60.5 60.5

77.5 77.5 77.5

– – –

0 25 50

0.13 0.26 0.39

10 15 20 30 40

50 60 75 80 100

10 15 20 30 40

50 60 75 80 100

10 15 20 30 40

50 60 75 80 100

2 3

Ampere Frame (AF)

Model Code

Number of Pole (P)

Rated Voltage: Ue Vac

Rated Current: In (A)at Ambient Temperature: 50˚ C

Rated Ultimate Short CircuitBreaking Capacity: I cu (kA)

240V/415V

a

b

c

ca

bb

aa

kgWeight

IEC 60947-2

aaa

b

cac

Page 59: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

M C B c h a r a c t e r i s t i c s & d i m e n s i o n s

58

BHQ & BHP series | operating characteristics

BHQ & BHP series | temperature characteristics

Page 60: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

59

BHQ series | fixed type front connection

BHP series | plug-in type front connection

1-pole 2-pole 3-pole

1-pole 2-pole 3-pole

Page 61: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

60

N O T E S

Page 62: Technical Catalogue - regismccb.com · 37-SDMS-03 NF250-MA. feature 6 company profile Since our inception in 1974, our company specializes in manufacturing low voltage circuit breakers

what is quality ?

We define quality as products having the highest

level of reliability, performance and design. Our

aim for quality is to meet the requirements of

other global markets and to exceed the current

international standards. With our in-house design

and development team, our range of products are

currently manufactured in accordance and

compliance to various international standards.

our road to quality

ManufacturerHwa Shih Electric Industrial Co Ltd14, 16 Lane 2, Pa Teh Road,Yinko District, New Taipei City, Taiwan R.O.C.Tel : +886 2 2678 3675Fax : +886 2 2678 0564Email : [email protected]