t.c. sÜleyman demİrel university graduate school …
TRANSCRIPT
T.C.
SÜLEYMAN DEMİREL UNIVERSITY
GRADUATE SCHOOL OF NATURAL AND APPLIED
SCIENCES
RADIATION SHIELDING PROPERTIES FOR SOME
COMPOSITE MATERIALS
Abdlhamed Faaq Abdlhamed ABDLHAMED
Supervisor
Prof. Dr. İskender AKKURT
Co-Supervisor
Asst. Prof. Dr. Zeynep PARLAR
THE DEGREE OF MASTER OF SCIENCE
DEPARTMENT OF PHYSICS
ISPARTA - 2018
© 2018 [Abdlhamed Faaq Abdlhamed ABDLHAMED]
i
TABLE OF CONTENTS
Page
TABLE OF CONTENTS .............................................................................................. i
ABSTRACT ................................................................................................................ iii ÖZET........................................................................................................................... iv
ACKNOWLEDGEMENTS ......................................................................................... v LIST OF FIGURES .................................................................................................... vi LIST OF TABLES .................................................................................................... viii 1. INTERODUCTION ................................................................................................ 1
1.1.Radiation and Properties ................................................................................... 1
1.2.The Types of Radiation ..................................................................................... 1 1.2.1. The Non-Ionizing Radiation ................................................................... 2
1.2.2. Ionizing Radiation .................................................................................. 2
1.2.2.1. Alpha (α) – Decay ........................................................................ 4 1.2.2.2. Beta (β)–Decay ............................................................................. 4 1.2.2.3. Neutron ......................................................................................... 6
1.2.2.4. Gamma ( )-Decay ........................................................................ 7
1.3. Gamma Interaction with Matter ....................................................................... 8 1.3.1. Compton Scattering ................................................................................ 8
1.3.2. Photoelectric Effect ................................................................................ 9 1.3.3. Pair Production ..................................................................................... 10
1.4. Radiation Measurements ................................................................................ 11 1.4.1. Gas-Filled Detectors ............................................................................. 12 1.4.2. Scintillation Detectors .......................................................................... 13
1.4.3. Semiconductor Detectors (Solid State Ionization Chambers) .............. 14 1.5.Biological Effects of Radiation ....................................................................... 15
1.5.1. Type of effects ...................................................................................... 15 1.5.1.1. Somatic Effects .......................................................................... 17
1.5.1.2. Genetic Effects ........................................................................... 18 1.6. Radiation Protection ....................................................................................... 19
1.6.1. Time ...................................................................................................... 19 1.6.2. Distance ................................................................................................ 19 1.6.3. Shielding ............................................................................................... 20
1.7. The Composite ............................................................................................... 21
1.7.1. Rubber .................................................................................................. 21 1.7.2. Jute ........................................................................................................ 23 1.7.3. Glass Fiber ............................................................................................ 24
2. THE LITERATURE BACKGROUND ................................................................ 26 3. MATERIALS AND METHODS .......................................................................... 31
3.1. Preparation Samples ....................................................................................... 31
3.2. Methods .......................................................................................................... 33
3.2.1. Gamma spectrometer system ............................................................... 33 3.2.2. NaI (TI) Detector .................................................................................. 34 3.2.3. Electronic units ..................................................................................... 35 3.2.4. Energy calibration ................................................................................ 35 3.2.5. Detection efficiency calibration ........................................................... 36
3.3. The Linear attenuation Coefficients Measurement ........................................ 37 4. RESULTS .............................................................................................................. 40 5. CONCLUSION ..................................................................................................... 52
ii
REFERENCES ........................................................................................................... 53
CURRICULUM VITA .............................................................................................. 57 ÖZGEÇMİŞ ............................................................................................................... 58
iii
ABSTRACT
M.Sc. Thesis
RADIATION SHIELDING PROPERTIES FOR SOME COMPOSITE
MATERIALS
Abdlhamed Faaq Abdlhamed ABDLHAMED
Süleyman Demirel University
Graduate School of Natural and Applied Sciences
Department of Physics
Supervisor: Prof. Dr. İskender AKKURT
Co-Supervisor: Asst. Prof. Dr. Zeynep PARLAR
Radiation since its discovery has been one of the facts of life. Radiation has always
been existed in universe even it is due to the different sources. Radiation is a
important research field as it is used in a variety of different field and also it is
hazardous for helath. Therefore development of radiation shielding materials has
been recently a vital research field. Thus development of a composite materials to
sheild radiation and testing it agains gamma-ray are main goal of this thesis.
Composite materials have been developed in Istanbul Technical University and they
were tested against gamma rays from 60Co and 137Cs sources in Suleyman Demirel
University.
Keywords: Radiation, Shielding, Composite Materials, Radiation Protection.
2018, 58 pages
iv
ÖZET
Yüksek Lisans Tezi
BAZI KOMPOZİT MALZEMELERİN RADYASYONA KARŞI KORUMA
ÖZELLİKLERİ
Abdlhamed Faaq Abdlhamed ABDLHAMED
Süleyman Demirel Üniversitesi
Fen Bilimleri Enstitüsü
Fizik Anabilim Dalı
Danışman: Prof. Dr. İskender AKKURT
II. Danışman: Yrd. Doç. Dr. Zeynep PARLAR
Radyasyon keşfinden bu yana hayatın gerçeklerinden biri olmuştur. Radyasyon
kaynağı gelişen teknoloji ile değişmekle birlikte doğada hep varolmuştur. Günlük
hayatta birçok alanda kullanılıyor olması yanında sağlık açısından zararlı etkilerinin
olması radyasyondan korunmayı önemli bir araştırma alanı yapmıştır. Bu nedenle
radyasyondan korunmak amaçlı olarak zırh malzemesi geliştirilmesi son zamanların
önemli konularından biridir. Bu yüzden zırh materyalinin (kompozit) özelliklerini ve
performansını değerlendirmek için bu çalışmanın temel amacıdır. İstanbul Teknik
Üniversitesinde geliştirilen zırh malzemeleri Suleyman Demirel Üniversitesinde 60Co
ve 137Cs gamma kaynakları ile test edilmiştir.
Anahtar Kelimeler: Radyasyon, Zırhlama, Kompozit Malzemeler, Radyasyondan
Korunma.
2018, 58 sayfa
v
ACKNOWLEDGEMENTS
I would like to thank God who helped me during all the steps of my study and gave
me the power and necessary patience to complete my thesis. I take this opportunity to
thank those people who were necessary for doing this work, and I am proud of them.
I am very grateful to my supervisor Prof. Dr. Iskender Akkurt for his expert
supervision of this work. His invaluable comments on the chapters of the thesis
enrich the whole work and for his words that always encourage me to work hard, and
I would like to thank him for all the recommendations during my study with him.
Also, I would like to thank my second supervisor, Asst. Assoc. Dr. Zeynep PARLAR
for her enthusiastic support of my project contributions and standing by my side in
the work period related to the experimental part of the composite work of my thesis.
With great thanks and respect.
I would like to thank Asst. Prof. Dr. Kadir GÜNOĞLU very much for everything he
did it for me, who helped me without fail during the study and measurements of
samples. My sincere greetings and appreciation.
And you, my dear family, you most of all deserve my gratitude. My dear mother,
brothers, and sisters; I give you my endless thanks for all your patience, support, and
love. I am lucky to have you. Yours affectionately.
Finally, I would like to thank all the friends who have stood and continue to support
me during my scientific career, you have all my love and appreciation.
Abdlhamed Faaq Abdlhamed ABDLHAMED
ISPARTA, 2018
vi
LIST OF FIGURES
Page
Figure 1.1. The electromagnetic radiations .................................................................. 2 Figure 1.2. Ionizing processes ...................................................................................... 3
Figure 1.3. Damage caused by radiation in DNA ........................................................ 3 Figure 1.4. The alpha particle ...................................................................................... 4 Figure 1.5. Beta minus (β-) emission ........................................................................... 5 Figure 1.6. Beta plus (β+) emission .............................................................................. 5 Figure 1.7. Neutrons Radiation .................................................................................... 7
Figure 1.8. Gamma decay ............................................................................................ 8 Figure 1.9. The mechanism of Compton scattering ..................................................... 9 Figure 1.10. Schematic of the photoelectric absorption process ................................ 10 Figure 1.11. Schematic of the pair production process and annihilation ................... 11 Figure 1.12. Schame of Scintillation Counter ............................................................ 14
Figure 1.13. Radiation effects on the whole body system ......................................... 17 Figure 1.14. Comparison of penetration of various radiations................................... 21
Figure 1.15. Rubber used in the composite ................................................................ 23 Figure 1.16. Jute used in the composite ..................................................................... 24 Figure 1.17. Glass-Fiber used in the composite ......................................................... 25 Figure 3.1. Samples composite .................................................................................. 31
Figure 3.2. Cutting and compressing devices ............................................................ 32 Figure 3.3. Heating procedure .................................................................................... 32
Figure 3.4. Schematic view of gamma Spectrometer and electronic units ................ 33 Figure 3.5. Schematic view of NaI (Tl) detector ....................................................... 34 Figure 3.6. Photography of NaI (Tl) detector ............................................................ 34
Figure 3.7. The decay scheme of 137Cs ...................................................................... 35 Figure 3.8. The decay scheme of 60Co ....................................................................... 36
Figure 3.9. Energy spectrum and related fit ............................................................... 36
Figure 3.10. Detection efficiency of NaI (Tl) detector as a function of gamma-ray
energies for 0,5 cm distance to detector face ........................................ 37 Figure 3.11. I and Io are measured count in detector respectively with and without
the absorber of thickness x (cm) ........................................................... 38
Figure 3.12. Intensity of gamma rays with and without materials for 60Co and 137C
sources ................................................................................................... 39
Figure 4.1. The relationship between 𝝁 (cm-1) and energy (keV) for all composite
samples .................................................................................................... 43
Figure 4.2. The relationship between 𝝁 (cm-1) and energy (keV) for R100, R90-J10,
R80-J20, and R70-J30 ............................................................................. 44
Figure 4.3. The relationship between 𝝁 (cm-1) and energy (keV) for R100, R90-
GF10, R80-GF20, and R70-GF30 ........................................................... 44
Figure 4.4. The relationship between 𝝁 (cm-1) and energy (keV) for R100, R70-J10-
GF20, R70-J15-GF15, and R70-J20-GF10 ............................................. 45
Figure 4.5. The relationship between 𝝁 (cm-1) and jute rate ...................................... 45
Figure 4.6. The relationship between 𝝁 (cm-1) and glass-fiber rate ........................... 46
Figure 4.7. The 𝜇 (cm-1) as a function of energy and also jute and glass-fiber rates for
R100, R70-J10-GF20, R70-J15-GF15, and R70-J20-GF10 ................... 46 Figure 4.8. The relationship between mfp (cm) and energy (keV) for R100, R90-J10,
R80-J20, and R70-J30 ............................................................................. 47 Figure 4.9. The relationship between mfp (cm) and energy (keV) for R100, R90-
GF10, R80-GF20, and R70-GF30 ........................................................... 47
vii
Figure 4.10. The relationship between mfp (cm) and energy (keV) for R100, R70-J10
GF20, R70-J15-GF15, and R70-J20-GF10 ........................................... 48 Figure 4.11. The relationship between transmission rate (%) and thikness (cm) for
R100, R90-J10, R80-J20, and R70-J30 ................................................ 49
Figure 4.12. The relationship between transmission rate (%) and thikness (cm) for
R100, R90-GF10, R80-GF20, and R70-GF30 ...................................... 50 Figure 4.13. The relationship between transmission rate (%) and thickness (cm) for
R100, R70-J10-GF20, R70-J15-GF15, and R70-J20-GF10 ................. 51
viii
LIST OF TABLES
Page
Table 1.1. Effects ocur ............................................................................................... 16 Table 3.1. Materials composite rates ......................................................................... 33
1
1. INTRODUCTION
Radiation is one of many facts in our life. Natural radiation exists in our whole life.
Heat and light from nuclear reactions in the sun are fundamental to existence. In
environment the occurrence of radioactive materials is natural, carbon-14, potassium-
40 and polonium-210 are natural radioactive materials found in our bodies. Radiation
discovery developed many fields of life (Wrixon and Clark, 2004).
Each radiation type has different properties. Non-ionizing radiation may shake or
move the molecules. Ionizing radiation could break molecular bonds, causing
unpredictable chemical reactions. Ionizing radiation has not only energy waves but
particles. Humans can not see, taste, feel, hear, or smell the ionizing radiation. The
exposure to ionizing radiation comes from cosmic rays and some materials are
natural. Human exposure to natural radiation is in question for certain numbers of
mutations and maybe cancers. Exposure of radiation above natural limites is a cause
for concern since it may result in diseases (Karam and Stein, 2009).
1.1. Radiation and Properties
There are additionally different forms, which we use in everyday in life, like
microwaves, radio waves, radar and X-rays for cooking, communication, navigation,
medical examinations, respectively. Radiation also comes from Radioactive
materials. These materials occur naturally, also produced others artificially. We can
classify radiations according to the effects they produce in the matter. There are two
categories, ionizing and non-ionizing radiations. Ionizing radiation includes cosmic
rays, X-rays and the radiations from radioactive materials. Non-ionizing radiation
includes ultraviolet light, radiant heat, radio waves and microwaves. We can also
classify radiation in terms of its origin as natural or artificial radiation (Harish, 2011).
1.2. Types of Radiation
There are two kinds of radiation, non-ionizing radiation and ionizing radiation
(Canadian nuclear safetly, 2012).
2
1.2.1. Non-Ionizing Radiation
Non-ionizing radiation is the radiation that does not have enough energy for ionizing
atoms or molecules. The electromagnetic (EM) spectrum includes all kinds of EM
radiation from the lowest to the highest energy, wavelength and frequency. EM
radiation is an energy that travels with light speed and spreads. The visible light that
originates from lamps in our homes and the radio waves originates from microwave
or radio stations are some examples of EM radiation that all we are using in our
homes. Figure 1.1 shows the whole electromagnetic spectrum including non-ionizing
and ionizing types. We can seen from this figure that gamma rays and X-rays are
ionizing and all other types are non-ionizing radiation (Alsarray, 2016).
Figure 1.1. The electromagnetic radiations (Alsarray, 2016).
1.2.2. Ionizing Radiation
Ionizing radiation has sufficient energy to take out electrons from an atom. If the
energy of radiation is not high for ionizing an atom then it can excite atom by taking
out an electron up to higher orbit rather than kicking it out from the atom (Figure
1.2). The DNA could be damaged by the ionizing radiation. The hazardous on cell
can be different according to the absorbed radiation dose, When the body is exposed
to a high amount of ionizing radiation it can lead to a cancer (Harish, 2011).
3
Figure 1.2. Ionizing processes (Harish, 2011).
From Figure 1.3, we can see that the radiation can effect DNA by two ways, directly
or indirectly, and it shows the effect of ionizing radiation on DNA. In all cases this
can lead to dangerous health problems (Alsarray, 2016).
Figure 1.3. Damage caused by radiation in DNA
4
1.2.2.1. Alpha (α) – decay
Alpha particle is ionized helium atom and can be obtained from radioactive decay of
nucleus (Figure 1.4). It occurs in elements that have higher atomic mass (A), usually,
alphe decay occures with nucleus are heavy, like radon or uranium, and those ratio
between neutron and proton is very big.
The emissions consider are particulate, so it takes an amount of energy away from
nucleus. The helium nucleus He2+ ; 2n + 2p is a massive 4 AMU particle with a
charge 2+. Nuclear state equation displays that the atomic mass number A is
decreased by (-4), Z protons number is decreased by (-2), and N neutrons number
decreases by (–2). (Smith, 2010).
𝑋𝑛 → 𝑌𝑁−2𝑍−2𝐴−4 + 𝐻𝑒2
2+24
𝑍𝐴 (1.1)
The alpha particles can be stopped by the sheet of paper.
Figure 1.4. The alpha particle
1.2.2.2. Beta (β) - decay
There are three kinds of this decay: beta minus, beta positive and electron capture:
Beta minus decay (𝛃−)
When the neutron number is greater than proton number. The nucleus will be
radioactive in this case, we can solve this problem by converting more neutron to
proton to move closer to the line of stability by:
5
𝑛 → 𝑝+ + 𝛽− + �̅� (1.2)
For example, 60Co has too many neutrons and one of them is converted to a proton,
an electron is created in the nucleus that will be emitted from the nucleus. (Figure
1.5) shows this process schematically. The penetration ability of beta particles is
greater than alpha particles. by a few centimeters of plastic or human body tissue.
Figure 1.5. Beta minus (β-) emission
Beta plus decay (β+)
When the proton number is greater than the neutron number in the nucleus which
will be radioactive, we can solve this problem by converting more protons to
neutrons:
𝑝+ → 𝑛 + 𝛽+ + 𝑣 (1.3)
Occures and through this process positron (positive electron) will be created in the
nucleus, then these positron will be emitted (Figure 1.6).
Figure 1.6. Beta plus (β+) emission
6
Electron capture
In the third case which is electron capture, proton will capture the closest electron
and will convert to neutron:
𝑝+ + 𝑒− → 𝑛 + 𝜈 (1.4)
In electron capture, a parent nucleus may capture one of its own electrons and emit a
photon and a neutrino. This photon may be an x-ray or gamma-ray photon. The x-ray
wave is emitted as one of the electrons in the higher orbitals fills the gap that left by
the electron was captured by nucleus (Mehmet, 2016).
𝐴𝑡 + 𝑒−10 → 𝑃𝑜84
218 85218
1.2.2.3. Neutron
Neutron radiation consists of a free neutron and it can ordinarily be emitted as a
result of induced or spontaneous nuclear fission. The neutron has no electric charge,
it can travel hundreds meters or thousand meters in the air. However, its
effectiveness can be stopped if it is exposed to hydrogen-rich substances. Because
mostly the interaction of neutron with the material is (n, p) reaction and thus proton
reach materials, for example concrete or water are applicable materials to shield
neutron. (Figure 1.7) shows the processes of neutron emission, There are kinds of
neutrons producing from the ionization process that can make matters radioactive or
substances, these procedures called the effective neutrons, which are a primary
method of fabricating radioactive sources used in the many fields of academic,
health, and industrial area and its several applications.
As we mentioned, the neutrons have high ability to travel perhaps thousands of
meters in the air and moderate distance (a few meters in the solids) because they
have high energy making them more penetration to the materials.
7
Figure 1.7. Neutrons Radiation
1.2.2.4. Gamma ( )-decay
Gamma radiations, also called as gamma rays, are electromagnetic radiation have
high frequency and therefore high energy with very short of wavelength (~10-3 A.U.
to 1 A.U.). Hence, they have no electric charges and can not be deflected by
magnetic and electric fields (Figure 1.8). Gamma rays are ionizing radiations and are
thus cause of biologically hazardous. They are produced of the decay of high energy
states of (highly unstable) of atomic nuclei. They can also be created in other
process. Also this ray can produced from naturally occurring radioactive isotopes,
and secondary radiations produced from atmospheric interactions with particles of
cosmic rays. Gamma-rays produced by the number of astronomical process in which
very high energy of electrons are produced that in turns cause secondary gamma
rays, inverse Compton scattering and Synchrotron radiation. Typically, gamma-rays
have frequencies above ten exahertz (or >1019 Hz), therefore have the energies above
100 KeV and wavelengths less than 10 pico-meters (less than diameter of an atom).
Gamma-rays from radioactive decays are defined as gamma rays no matter what
their energy. Gamma decay commonly produces energies of a few hundred of KeV
and almost less than 10 MeV (Gorden, 2011).
8
Figure 1.8. Gamma decay
1.3. Gamma Rays Interaction with Matter
Three main photon interactions mechanisms, they are: photon scattering (elastic or
inelastic), photoelectric effects, and pair production. In this section, each of
those processes is shortly delineate beside its effects from a radiation attenu-
ation purpose of view. When gamma-rays are passing through the matter, the
probability of absorption in a thin layer is proportional to the layer thickness. This
can lead to an exponential of intensity decrease with the thickness, which is
formulated in following equation:
I (x) = Ioe−μ𝑥 (1.5)
Where, 𝜇 = 𝑛. 𝜎 is the coefficient of absorption, measured in cm−1, I is the atoms
number per cm3 in the material, 𝜎 is the absorption cross section in cm2 and x is the
material thickness in cm (Angüner, 2008).
1.3.1. Compton Scattering
Compton scattering is a direct interaction of the incident gamma photon with a
loosely bound (outer shell) electrons in the absorbing material, transferring only a
part of the incident gamma ray energy to the kinetic energy of the recoil electron.
The interaction results are that the incoming photon is treated in energy and deflected
from its original direction and an electron called as a recoil electron is generated.
This energy can be different from zero (θ=0) to a significantly large fraction of the
9
original energy of the gamma ray (θ=π), depending on scattering angle. (Figure 1.9)
shows a schematic of Compton scattering process.
Figure 1.9. The mechanism of Compton scattering
1.3.2. Photoelectric Effect
In the photoelectric absorption, an incident energy photon is completely absorbed by
an atom and one of the electrons is released, creating an ion and free electron. Then,
an energetic electron known as a photoelectron is removed from one shell of the
electron shells with a kinetic energy given by incident photon gamma energy Eγ (hν)
(Figure 1.10). Minus binding energy of electron in its origin shell (Eb). For that case
to occur photoelectric effect, the incident photon energy must be greater than the
binding energy of the inner shell electron. The photoelectric absorption process is
shown schematically in the diagram below. The energy of the ejected photoelectron
can be expressed as follows:
𝐸𝑒− = ℎ𝜈 − 𝐸𝑏 (1.6)
Where Ee- represents the kinetic energy of the photoelectron, and Eb is the binding
energy of the photoelectron's original shell. When an electron in one of the bound
electron shells is ejected from the atom by an external excitation x-ray or gamma
photon, a vacancy is created. A free electron can then be captured from the medium
or a rearrangement of electrons from outer shell orbits of the atom then fills this
vacancy leading to the emission of characteristic X-ray and this in turn, produces a
hole in the L or M shell (Peshawa, 2015).
10
Figure 1.10. Schematic of the photoelectric absorption process
1.3.3. Pair Production
Pair production is the third significant process for gamma-ray photons interactions in
matter. This interaction occurs at the points which are closes to the nuclei of the
absorbing material due to the high electric field. This process occurs within the
Coulomb field of the nucleus resulting in the conversion of gamma ray into an
electron-positron pair. For this quantum mechanical effect, gamma ray should be
carried an energy at least equivalent to the combined rest mass of two particles
making 1022 keV in all. Therefore, minimum γ-ray energy of 1.022 MeV is required
for any incident photon to under go this process. Any excess energy carried in by the
photon above 1.022 MeV is transferred into kinetic energy which shares by the
electron_positron pair. Total kinetic energy of the electron_positron pair is given by
following equation:
𝐸𝑒− + 𝐸𝑒+ = ℎ𝜈 − 2𝑚0𝑐2 (1.7)
After electron and positron pair is created, they typically travel a few millimeters in
the material before losing their energies in the absorbing medium. As the positron
slows down, it can combine with an atomic electron in the surrounding material and
subsequently annihilate to form two photons, called annihilation photons, each with
energies of about moc2 = 0.511 MeV which are emitted back-to-back (to conserve
linear momentum). Generally, the annihilation of pair of an electron-positron does
not occur until the energy of the posıtron reduced to near thermal energy, releasing
two energies of 511 keV. Figure 1.11 shows pair production process schematically.
11
Figure 1.11. Schematic of the pair production process and annihilation
1.4. Radiation Measurements
The radiation has been measured by the scientists, they used several idioms depend
on if they are discussing radiation is coming from radioactive sources, the dose of
radiation which absorbed by a person, or the biological risk that affects on a person's
health. Most of the scientists in the international community measure radiation by
using the System International (SI), which is a uniform system of weights and
measures that developed from the metric system. In the United States, however, the
traditional system of measurement is still used. They used different measurement
units depend on which aspect of radiation is being measured. The amount of
radiation emitted, by a radioactive material measured using the conventional unit
Curie that came from the name of famed scientist Marie Curie (CI), or the (SI) unit
Becquerel (Bq). The radiation dose absorbed by a person is measured by using (rad)
or gray (Gy). The biological risk of exposure to radiation measured by using REM or
Sievert (https://emergency.cdc.gov/radiation/measurement.asp).
The measurement unit of emitted radiation is Bq in the SI unit or Ci in the
conventional unit. When the nucleus has many particles, too much energy, or too
much mass will emit radiation to get stability. The nucleus disintegrates, in an
attempt to reach a stable case. As the nucleus disintegrates, energy is emitted as
radiations. The Ci or Bq is used to express the number of disintegrations of
radioactive atoms in the radioactive materials over a time period. For example, one
12
Ci = 37 billion (37 × 109) disintegrations per 1s. The Ci is being substituted by Bq.
Since the one Bq is equal to one disintegration per second, one Ci = 37 billion (37 ×
109) Bq. Ci or Bq could be used to assign to the amount of the radioactive materials
released into the environment.
When a person is exposed to the radiation, the energy is deposited in tissues of the
body. The amount of energy deposited per unit weight of the human tissue is called
the absorbed dose. The Absorbed dose is measured by using the conventional unit is
rad or the SI unit is Gy. The rad, which stands for radiation absorbed dose, was the
conventional unit of measurement, but it has been changed by the Gy where (Gy =
100 rad) (Knoll, 2010).
There are various types of radiation detectors such as: gas-filled detectors,
scintillation detectors, semiconductor detectors. Radiation detectors and detection
systems are also classified according to their physical form (gas, liquid, and solid
materials). Some of them may provide different types of information about radiation,
such as its energy, intensity, and/or the type of radiation which is being measured. In
general the methods of detection are based on the process of ionization or excitation
of atoms in the detector by the passage of a charged particle (Peshawa, 2015).
1.4.1. Gas-Filled Detectors
It is known that people cannot feel, smell, see or test ionizing radiation and therefore
it was necessary to rely entirely on special devices detection and measurement of
radiation. Several detector types take benefit of the ionizing effect of radiation on
gases. It can be collected the ion pairs separately. When a potential gradient is
applied between the two electrodes in a gas-filled ion chamber, the positively
charged molecules will move to the cathode and the negative ions (electrons) will
move quickly to the anode, thereby generating a measurable pulse. These pulses can
be easily measured by the associated devices as integrated current. There are three
main kinds of Gas-field detectors:
1- Ionization Chamber
2- Proportional Counter
3- Geiger-Mueller Counter
13
All are based on the collection of the electrical charge from the detector as a result of
the collection of the charges made in the detector chamber (Flakus, 1982).
1.4.2. Scintillation Detectors
The scintillation counter is a useful tool when counting gamma rays. The efficiency
is high and it has proper solving power. An important feature of this detector is that
the energy of the emitted photon is proportional to the incoming radiation. It gives
informations about the type and of radiation energy coming from this situation.
This process is also considered as one method available is the most useful for the
spectroscopy and detection of a variety of radiations widely. These are properties of
the ideal scintillation material that should have it:
1. Should change the kinetic energy of charged particles into detectable light with a
large scintillation qualification.
2. The light produced should be proportional to the deposited energy over a wide
range as possible.
3. The medium should be transparent to the wavelength of emission for good light
summation.
4. The decay time of the resulted scintillation must be short so that quick signal
pulses may be created.
5. The materials should be of good optical quality and subject to industry in sizes
large enough to be of usefulness.
6. The indicator of refraction should be close to that of glass (-1.5) to allow efficient
coupling of the scintillation light to a photomultiplier tube or other light sensor
(Knoll, 2010).
The energy of the radiation coming into the conduction band with the excited
electrons makes the return to the valence band at least once and then emits a photon.
This photon falls into the photocathode, causing a photoelectric phenomenon, which
results in a photocathode electron sputtering. The output pulses come to fruition as
these electrons, which are broken, are amplified and accelerated by the dyads found
in a photomultiplier tube (Figure 1.12).
14
Figure 1.12. Schame of Scintillation Counter
At the present time, the most commonly detectors used are sodium iodide (NaI), and
High Purity Germanium detector (HPGe). Both of these spectrometers have their
advantages and disadvantages. Sodium iodide scintillator NaI (Tl) is the most
frequently used because it has a high efficiency for detecting gamma radiation and
does not require cooling, while HPGe detectors provide superior energy resolution.
Scintillation detectors designed for use in different applications are divided into three
groups:
Inorganic scintillators (NaI (Tl), CsI (Tl), CsI (Na), LaBr3 (Ce) etc.).
Organic scintillators (Anthracene crystal, POPOP liquid, Stilbene Crystal etc.).
Plastic scintillators (NE102A, BC400, BC406, etc.).
1.4.3. Semiconductor Detectors
The primary ionization should be collected to make the direct measurements of the
nuclear radiation energy. Condensed, the phases have higher densities than gases
and so provide more efficient stopping of the radiation per unit of length. However,
the metals allow rapid recombination of the electron-positive ion pairs and
insulators inhibit the collection of charge. Therefore, only semiconductors are
extensively used for detection of radiation. Metals and insulators like concrete are
15
used extensively in the shielding of radiation, also some transparent inorganic
crystals have a special sensitivity for radiation.
The most common semiconductors used to construct "solid state ionization
chambers" are silicon and germanium. These materials should be extraordinarily
pure to look at the primary ionization (~ 105 electrons). The germanium devices
should be cooled for reducing the thermal noise to look at the outcoming
signals. The properties of small-scale devices based on the groups III and V
materials, e.g. GaAs, have been studied but no large- scale applications have been
made. The size and shape of the available semiconductors have grown with time but
are still severely limited by production techniques and the availability of high purity
materials.
Early solid state device relied on observing the ionization in semiconductors. The
early devices were impractical due to the requirement of extremely pure materials.
Modern devices are based on the junction diodes. These diodes have a rectifying
junction that only allows one direction of the flow current. Incident radiations
creates ionization inside the bulk of the diode, and creates a pulse of current in the
opposite direction to the normal current flow through a diode that is straightforward
for detection (Knoll, 2010).
1.5. Biological Effects of Radiation
One quality of the ionizing radiation on body of human is that the energy absorbed
is low but the biological effects are reality. For example, after receiving dose 10 Gy
from lethal, the temperature of body only will increase by 0.02o C, but the dose can
lead to death of all the exposed entities. The second quality is the latent radiation
biological effects. Acute biological effects may occur within hours to several days,
while the long-term the effects appears usually several years after exposure.
1.5.1. Type of effects
According to the subjects which the effects will occur, we can classify the biological
effects of radiation to two types: Somatic effects and Genetic effects, see (Table1).
16
Table 1.1. Effects occur
Characteristic of
effects Occurring time Object Effects on organs
Deterministic
Effects
Acute Effects
Somatic Effects
Skin damage
Damage of
reproductive system
Damage of blood
forming system
Damage of digestive
system
Damage of central
nervous system
Latent Effects
Cataract
Damage of
immunization system
Stochastic Effects Cancer
Genetic Effects Heredity effects
The deposition of energy by ionization could be a random method. Even at terribly
doses there is some probability that enough energy could also be deposited into a
vital volume among a cell to lead to cellular changes or cell death. But because
of the exceptional ability of cells to repair harm, enzymatic, and repair mechanisms
would lead in several instances to the proper DNA repair and also
the cell can survive with none modification to its perform or genetic structure.
Another result is likely to be a boom a mutation. The cell will survive but with
modulation in the DNA sequence for the cell’s genome. The mutated cells have the
ability for reproduction and thus perpetuate the mutation. If the mutated cell is a
somatic cell, the mutation could be a result of a malignant tumor. If the mutated cells
are germ cells, it could lead to a hereditary effect. These are stochastic effects and
their results cancer or hereditary effects. (Figure 1.13) shows both ways by which
radiation can affect the whole system of the body (Domenech, 2016).
17
Figure 1.13. Radiation effects on the whole body system
1.5.1.1. Somatic Effects
The somatic effects of radiation can be classified as Cataract and Cancer Induction as
detailed below.
A. Cataract Induction
The eye lens are different from other organs in that injured or dead cells are not
removed. Single dose of various of hundred rem have chosen opacities that overlap
with vision among a year. Larger dose is required when the doses are fractionated
over a period of a many years, and the cataract appear various years after the last
exposure. BEIR Report (1990) (a report stated by specific committees of National
Research Council) noted that the cataract induction may not be a trouble for the
doses currently permitted radiation workers (National Research Council (US), 1980).
18
B. Cancer Induction
Cancers arise in an exceeding sort of tissues and organs that are thought to be the
basic somatic effect of the low and medium exposure to radiation. Organs and tissues
vary greatly in their disposition to cancer inducement by radiation. Inducement of
leukemia by the radiation features because of the natural rarity of the disease
(National Research Council (US), 1980).
1.5.1.2. Genetic Effects
A mutation can be defined as an inheritable issue in the genetic materials inside the
chromosomes. Generally, mutations can be classified into two types, dominant and
recessive. The effects of dominant mutations can usually be seen in the first and
subsequent generations while the effects of recessive mutations can not be seen until
a child receives a similarly changed gene for that trait from his parents. This may not
be recorded for many generations or it may never be. Mutations can be a harmful
cause when it ranges from undetectable to fatal. In this part, the mutational effects
mean only those inheritable conditions which are usually hard enough to require
medical care in a person's lifetime at some time.
ICRP estimated the induced radiation probability which hard hereditary effects in all
workers population of a radiation to be 6Χ10−5 per rem. UNSCEAR report concluded
that about ¼ of the affected descendants could be grandchildren and children. This
information could be gathered with the average annual dose about 10 millirem to
estimate the genetic risks of our research and workers in the field of laboratory
medicine radiation. Assuming that 11 years of exposure before to conception (The
average age of fathers at the time of birth in the US is 29, while the average age of
the mother is less than 29 yeas. The minimum age for occupational exposure to the
ionizing radiation is 18 years), and the chance of a serious birth trouble in all
descendants of the workers due to previous occupational exposure is less than one in
a hundred thousand due to previous the occupational exposure 11 0.01 6 10−5 ∼
7 10−6. This hazard is very low, and many experts state the risk to be nonexistent.
However, it must not be surprising for such a small dose. For perspective, the
radiation dose due to single round trip air flight may be as high as 20 millirem,
19
substantially higher than the average annual dose of research and workers are
working in laboratory medicine (National Research Council (US), 1980).
1.6. Radiation Protection
The organisms are continuously exposed to radiation in daily life and may be
biologically hazarded if the exposure is direct and for a long time without shield
prtection, Therefore, there are three main ways to protect against radiation impacts
(Time, Distance and Shielding), It should be noted, that the best way to protect
against radiation that all these factors work at same time.
1.6.1. Time
It is the first and simplest rule to protect from radiation. Applications using
radioactive sources should be completed as soon as possible, according to the
Permissible Maximum Dose "ALARA: As Low As Reasonably Achievable"
principle (Silva, and et al., 2008). The dose absorbed by the radiation-exposed
substance varies with time. The exposure speed (exposure in unit time) at a distance r
from a source with A activity is given by the following formula. where Γ is a
constant connected to the source.
△ 𝑋 = Γ 𝐴
𝑟2 Δ𝑡 (1.8)
1.6.2. Distance
The free pathways of particulate radiation such as alpha and beta radiation, even in
air, are rather short. Neutron and gamma radiation, however, take longer to travel
than others, but their intensity decreases with distance. For this reason, one of the
effective ways of avoiding damage to a radiation source is to keep it as far away
from the source as possible. The amount of radiation that is exposed varies
depending on the distance according to inverse square law. To confirm this, it is
enough to assume that the rays emerging from the source at the same time form
spherical wavefronts at a distance r after a time t. Thus, the intensity of the rays on
20
the surface of any spherical wave ceiling is inversely proportional to the intensity of
the source Io and the area of the sphere surface.
𝐼 ∝ 𝐼𝑜
4𝜋𝑟2 (1.9)
Here, I is a radiation intensity is at a distance r. Also, the dose rate D2 at a distance d2
is smaller than that at distances d1 from the dose rate D1 at another distance d1
(d1 <d2).
𝐷2 = (𝑑1
𝑑2)
2
𝐷1 (1.10)
1.6.3. Shielding
Shielding is a barrier between the radiation source and the system intended to protect
it from radiation to destroy or minimize the effects of radiation. The main purpose of
the armor is to allow the emitted radiation to interact with the atoms of the armor
material to lose all or part of their energy. The type and energy of the radiation is
important in the selection of the shielding material to be used for this purpose.
Because the mechanisms of interaction of nuclear radiation with matter vary
depending on the load, mass and energy they possess.
When the penetration capabilities of radiation into matter are compared, it turns out
that the most dangerous types of radiation are gamma and neutron. Neutrons are
unloaded; gamma rays are both uncharged and massless. Figure 1.14 shows the
penetration of different types of radiation in different materials.
21
Figure 1.14. Comparison of penetration of various radiations
1.7. The Composite Materials
The composite can define as a combination of different materials in the composition,
where the particular constituents keep their separate identities. These separate
constituents work together to give the needed mechanical strength or the hardness of
the parts in the composite. Composite materials are composed of two or more several
phases. In the recent years, a rapid growth happened in the exhaustion of fiber
reinforced polymer, yielding an individual composition of high performance, large
versatility and processing features at favorable costs by permutation and composition
of different fibers and polymers, a wide range of composites, having individual
properties to applications as alternatives to ordinary materials like woods, metals,
etc. have been produced (Azim, 2017).
In this study of radiation shilding were prodused the composite contain three
materials are: Rubber as the main material, Jute and Glass-Fiber.
1.7.1. Rubber
Rubber can be defined as a material that may be compressed or stretched when the
pressure is removed and will back quickly to its original state, without permanent
perversion. The elastomers or elastic polymers are the primary chemical building
blocks of rubber, These are large chain like molecules, which when cured
22
(vulcanized) form chemical crosslinks between the chains of polymer. The ability of
the chains to stretch and spring back is a measure of the rubber’s elasticity and
resilience under pressure. The first common elastomer was Polyisoprene is made
from natural rubber. In general, rubber materials are identified by their low elasticity
modulus. They are resistant to water, alkalis and weak acids. Rubber is also a good
electrical insulator and can be used as a bonding factor. There are two types of
rubber are natural and synthetic. Natural rubber is produced from the latex (milky
juice) of the Hevea Brasiliensis tree. It is, therefore, a renewable resource unlike
synthetic rubber, which is produced from petrochemicals.
Natural rubber is harvested as latex, a natural source of isoprene, named
caoutchouc or India rubber which is dried out for trade processing. This form of
natural rubber dried out is the chemical Polyisoprene. Although it has some
elasticities, Polyisoprene is mixed with chemicals and vulcanized to make the
completed product. Natural rubber is both elastic and viscous making it a model
polymer for the effective and static engineering applications.
Synthetic rubber is made from oil by-manufactures using either solution or
emulsion polymerisation mechanisms Figure 1.15. Applying polymer chemistry
techniques allow greater opportunities for customisation of mechanical properties
and increased resistance to temperature, chemicals, and solvents than is possible with
natural rubber. Synthetic rubber properties are far wider than those of natural rubber.
There are up to 20 different classes of synthetic rubber giving a far wider choice of
rubbers to meet the wanted mechanical properties, temperature, and chemical
resistance, required for a specific application, synthetic rubber may have the
following advantages over natural rubber like more resistant to oil, certain chemicals
and oxygen, better aging and weathering resistance, resilience over a wider range of
temperature (Awagon, 1996).
The rubber is used in the composite which prepared from recycled footwear comes
from the base of the bottom of the sports shoes that the athletes are using it (Yıldız,
F., et al., 2017).
23
Figure 1.15. Rubber used in the composite (Lee, M. J., & Rahimifard, S., 2012)
1.7.2. Jute
Jute is produced from the genus Corchorus plants Figure 1.16, which has about 100
kinds. This is one of the cheapest natural fibers, with highest manufacture volume.
Bangladesh, India, and China supply are the best situations for the growth of the jute.
Ray and co-workers investigated widely alkali cure jute fiber reinforced with vinyl
ester resin. In their studies, they considered the mechanical, thermal, dynamic, and
impact fatigue behavior compared with that of untreated jute fiber–vinyl ester
composites. Longer alkali treatment ejected hemicelluloses and improved the
crystallinity, enabling better dispersion of the fiber. The impact, thermal, dynamic
and mechanical properties were excellent owing to the alkali treatments, contain
treatment time, concentration and situations. The enhancements in tensile strength
above 50%, in bending strength about 30%, and in impact strength 90% were spotted
in composites and are comparative to values achieved for pure Biopol sheets.
Degradation studies displaied that after 150 days of compost burial more than 50%
weight loss of jute/Biopol composites happens.
24
Figure 1.16. Jute used in the composite
The effects of hybridization on the tensile properties of jute–cotton woven fabric
reinforced polyester composites were studied as a function of the fiber contents,
orientation, and roving texture. It was spotted that tensile properties along the
direction of jute roving alignment increase steadily with fiber content above to 50%
and then show a slope to decrease. The tensile strength of composites with 50% fiber
content in parallel to the jute roving is about 220% higher than pure polyester resin.
Jute fiber reinforced PP composite was evaluated regarding the effect of matrix
preparation, the effect of gamma radiation, the influence of interfacial adhesion on
creep and dynamic mechanical attitude, the effect of silane coupling agent, and the
effect of natural rubber. The properties were studied of jute/plastic composites,
including the thermal stability, crystallinity, modulation, trans-esterification,
weathering, durability, fiber orientation on frictional and wear attitude, eco-design of
automotive components, and alkylation. Polyester resin used as a matrix for jute fiber
reinforced composite and the relationship between water absorption and dielectric
attitude, the elastic properties, notched strength and fracture criteria, impact damage
characterization, weathering, and thermal attitude, and effect of silane treatment was
examined (Faruk, 2012).
1.7.3. Glass Fiber
Glass Fibers are among the most multilateral industrial materials known nowadays.
They are readily prepared from the raw materials, which available provide in
virtually unlimited. They display useful bulk properties like transparency, hardness,
25
resistance to any chemical attacks, stability, and inertness, as well as wished for fiber
properties like flexibility, strength, and stiffness. Glass-fibers are used in the
preparation of structural composites, printed circuit boards and a wide range of
special objective products. Glass melt is made by fusing (co-melting) silica with
minerals, which contain the oxides necessary to form a given composition. The
molten mass is quickly cooled to prevent crystallization and created into glass-fibers
by a fashion also known as fiberization (Figure 1.17) (Wallenberger, et al., 2001).
Figure 1.17. Glass-Fiber used in the composite
Glass fiber preparation is the conversion of different raw materials (predominantly
borosilicates) with high-temperature into a homogeneous melt, followed by the
fabrication of this melt into glass fibers. The two main types of glass fiber products,
textile, and wool, are manufactured by similar processes. Glass fiber production may
be classified into three stapes: raw materials handling, glass melting, and wool glass
fiber forming and finishing, this last stape being slightly different for textile and
wool glass fiber preparation (Industry, W. F. I. M., 1983).
26
2. THE LITERATURE BACKGROUND
There are many studies and scientific experiments on radiation shielding because it is
a very important subject to protect against the risk of radiation and its impact on
human health. In this section, a summary of some works and experiments related to
radiation protection and reduction of risks to human life is presented.
I. Akkurt and his team, (2004), the linear attenuation coefficients and total mass
attenuation coefficients of gamma rays for barite, marble, and limra were obtained.
The results show in the high energy region that attenuation begins to increase.
Increasing the attenuation coefficient of photons, while increasing the photon energy,
results in successive collisions due to Compton scattering. The calculations also
show that the linear attenuation coefficients increased with increasing the density of
materials, and mass attenuation coefficients remain constant.
C. Basyigit and other, (2005), Investigated the photon attenuation coefficients for
marble. The total linear attenuation coefficients μ (cm−1) have been obtained using
the XCOM program at the energies of 1 keV to 1 GeV for six various types of
natural marbles. The results show that the linear attenuation coefficients μ depend on
the photon energy, and even at low energy slight fluctuation has been spotted
between the results of calculations, there are no significant differences at higher
energies. The linear attenuation coefficients μ decrease clearly at low energy Eγ
0.1 MeV, decrease clearly in the middle 0.1 MeV Eγ 10 MeV and slightly
increase in high energy Eγ 10 MeV.
M. A. Mosiewicki and other, (2007), natural rubber NR effect on Wood Reinforced
Tannin Composites was investigated, natural rubber latex was added to the
composite materials formulated from a quebracho tannin adhesive crosslinked with
hexamethylenetetramine and wood flour as a filler. The impact properties presented a
similar trend, with the largest change happening between 0 to 5% natural rubber in
the matrix formulation.
Ibrahim Turkmen and other, (2008), they have calculated radiation attenuation
coefficients in Portland cements were mixed with silica fume, blast furnace slag and
natural zeolite, the radiation attenuation coefficients expressed as mass attenuation
27
coefficients for Portland cement, zeolite, blast furnace slag, silica fume and their
mixed kinds in function of the Photon energy over the energy range of 1 keV and 2
MeV. It was spotted that the different percentages of constituents in cement and that
cement mixed with different additives such as zeolite, silica fume and blast furnace
slag, lead to important variations in total mass attenuation coefficients. The elemental
samples compositions were resolved using a wavelength dispersive XRF
spectrometer. The calculated values of total mass attenuation coefficients were
looked on the basis of different percentages of cement constituents and cement
mixed with different additives.
I. Akkurt and other, (2009a), investigated photon attenuation coefficient for pumice,
where it was measured the linear attenuation coefficients of two different kinds of
Golcuk-Isparta pumice which are alternative building materials were measured. The
results were compared with calculation and some other materials where the results
showed that the linear attenuation coefficients are higher for compressed pumice than
for natural pumice.
M.E. Medhat, (2009b), calculated gamma ray attenuation coefficient of some
building materials in Egypt, calculated by XCOM Program, the mass attenuation
coefficients l/q for building material samples were measured for five energies which
are 59.5, 356.5, 661.6, 1173.2 and 1332.5 keV, the materials were studied here
represent walls (three types of red clay bricks) and roofs (cement, gypsum and
concrete) representative of those used in Egypt. Bricks were covered in two sides by
the cement, which is used in inner walls, may protect from radiation about 46–67%
more than brick itself. Concrete was covered by two gypsum layers and cement,
which is used for ceilings, the protection efficiency increased about 6% more than
concrete itself.
I. Akkurt and his team, (2010a), measured the radiation shielding of concrete
containing zeolite, the μ for concrete which contain zeolite as an aggregate
concentrations differently 0%, 10%, 30% and 50%, the results were compared with
the calculations. The linear attenuation coefficient measured with four blocks of
concrete were decreased with increasing zeolite concentration. It was concluded that
the addition of zeolite as an aggregate in concrete was not an alternative option to be
used for the purposes of radiation shielding.
28
I. Akkurt and other, (2012a), studied photon attenuation coefficients of concrete
including marble aggregates. The linear attenuation coefficients for the six different
types of concretes were measured at photon energies of 662, 1173 and 1332 keV and
calculated at photon energies of 1 keV–100 GeV. The measurements linear
attenuation coefficients were decreased linearly with increasing photon energy for all
kinds of concrete. It is also clear, that decreasing of linear attenuation coefficients
with the increasing of the photon energies.
K. H. Mahdi, (2012b), studied and calculated gamma ray attenuation coefficients for
different composites. The linear attenuation coefficient was displayed as a function
of the applied energy. It was clear that the linear attenuation coefficient sharply
decreased with the increase of the photon energy in the range between 0.1 to 1 MeV
for all composites. Such a behavior could be ascribed to the photoelectric and
compton scattering which were the main predominant interactions in this region.
This sharp decrease was considered to be an indication that the μ was very sensitive
for the photon energy.
Akkurt and his team, (2013a), investigated and measured the radiation shielding
properties of iron doped into clay samples at 662 keV. The measurements were
performed using gamma spectrometer system which contains NaI(Tl) and 16k MCA
analyzer.
Mohammed M. Al-Humaiqani and other, (2013b), examined gamma radiation
shielding properties of high strength high performance concretes prepared with
different types of normal and heavy aggregates. It was found that the compressive
strength of the normal concrete had almost no effect on the attenuation of gamma
rays. The Linear and mass attenuation coefficients were calculated and compared
with the past researchs and a good agreement was found. However, the HPCs density
considerably affected the attenuation of gamma rays. With the increase in the
density, the attenuation coefficients increased linearly. This endorsed that the
relationship between HPC density and the gamma attenuation coefficients was linear.
Rezaul K Khan and other, (2014a), comparative experimental studies on the physico-
mechanical properties of jute caddies reinforced polyester and polypropylene
composite, non-woven jute caddies (JC, jute wastage) reinforced unsaturated
29
polyester resin (UPR) and polypropylene (PP)-based at random oriented
discontinuous fibre composites with fibre loading 40-65% were fabricated by
compression molding, the composites were irradiated with gamma rays 60Co of dose
varied from 2.5 kGy to 12.5 kGy. Tensile and flexural properties of the composites
were found to be improved significantly after irradiation. TS and BS of JC/UPR
composites were increased 29.86 and 14.60% respectively at 7.5 kGy, while for
JC/PP composites the increments were 21.69 and 7.78% respectively at 5.0 kGy.
Sardar M Shauddin and others, (2014b), studied the effects of fiber inclusion and γ
radiation on physico-mechanical properties of jute caddies reinforced waste
polyethylene composite, jute mill wastage which is known as jute caddies (JC)
reinforced waste polyethylene (WPE)-based low cost at random oriented
discontinuous fibrous composite was fabricated by using traditional hand layup
method. Fourier Transform Infrared Spectroscopy (FT-IR) was used for investigation
the chemical composition of both raw jute and jute caddies. Jute caddies content in
the composite was varied from 20 to 45% where, 32% JC enriched composite
showed that the best performance in mechanical tests, both types of composites were
irradiated with gamma rays of dose varied from 2.5kGy to 12.5 kGy, where
composites irradiated with 5 kGy dose leads to the best results.
TP Sathishkumar and his team, (2014c), studied glass fiber-reinforced polymer
composites, glass fiber reinforced polymeric (GFRP) composites were the most
commonly used in the preparation of composite materials. Ultimate tensile strength
and flexural strength of the fiber glass polyester composite was increased with
increasing in the fiber glass Vf of fiber weight fractions. The elastic strain of the
composite was increased with the fiber glass Vf over 0.25, and then subsequently
decreased with further increase in fiber glass Vf. The Young’s modulus of elasticity
of the composite increased with the fiber glass Vf.
Raghavendra Supreeth B.S and his team, (2015), studied the effects of gamma
irradiation on the mechanical properties of natural fibers reinforced hybrid
composites, using of natural fibers as reinforcement in polymeric composites for
technical applications has been a research subject of scientist. These test samples
were exposed to different doses of gamma radiation in the range of 1-20 kGy. Then,
mechanical properties of hybrid composites were tested by using computerized UTM
30
machine as per the ASTM standards. The hybrid composites were irradiated with 5
kGy radiation dosage lead to the best results.
Esraa Alsarray, (2016a), investigated radiation shielding properties of some
composite materials. The measurement showed that the barite was an important
materials to shield against gamma rays. With the increasing barite rate in composite
material, the linear attenuation coefficients were also increased.
M. A. Çakıroğlu and others, (2016b), investigated radiation shielding properties of
polypropylene fiber reinforced shotcrete. For this purpose, measured linear
attenuation coefficient for shotcrete reinforced with polypropylene fiber, produced
using the dry mixing process. Measured the linear attenuation coefficients for dry
mixed shotcrete at photon energies of 1173, 1332 and 662 keV. The measurements
were carried out by using gamma spectrometer containing NaI (Tl) detector and a
Multichannel Analyzer (MCA), the linear attenuation coefficients increased with the
increasing fiber percentage for all studied gamma energies.
31
3. MATERIALS AND METHODS
3.1. Preparation Samples
In the study of linear attenuation coefficient μ (cm-1), Rubber as a main material, Jute
and Glass-Fibre (R-J-G/F) as additions to composite in (Figure 3.1) were used to
produce ten samples with different rates. The average sizes of these composites about
(L8.5, W5.5, Th2) cm, the average thickness about 2cm. All preparation and
production of samples have been done according to the details given in (Table 3.1).
The composite materials were manufactured in Istanbul Technique University's
laboratory ( Parlar, Z., et al., 2015).
At first, the procedure was to cut Rubber by the cutting device, also cutting Jute and
Glass-fiber to small pieces, then, the materials were mixed with hands, after that, we
put the mixed materials in a mold for a few minutes under the compressing device.
The oven was heated about 150°C while the mold inside. Finally, we took the
components out of the oven, see (Figure 3.2 and 3.3). and cutting them according to
the sizes that mentioned above.
.
Figure 3.1. Samples composite
32
Figure 3.2. Cutting and compressing devices
Figure 3.3. Heating procedure
33
Table 3.1. Materials composite rates
No Sample Rubber (%) Jute (%) Glass-
Fibre (%)
Thickness
(cm)
1 R100 100 - - 2
2 R90-J10 90 10 - 2,1
3 R80-J20 80 20 - 2,1
4 R70-J30 70 30 - 2,2
5 R90-GF10 90 - 10 1,9
6 R80-GF20 80 - 20 2,1
7 R70-GF30 70 - 30 2
8 R70-J15-GF15 70 15 15 2,3
9 R70-J10-GF20 70 10 20 2,1
10 R70-J20-GF10 70 20 10 2,1
3.2. Methods
3.2.1. Gamma ray spectrometer system
Gamma spectrometer system is applied to know if a material is radioactive,
radioactive, or the source of radioactivity. Also it can identif gamma rays energy of
the samples. It consists of a detector which is NaI(Tl), counting electronic system
(spectroscopy amplifier, high voltage, Multichannel Analyses MCA) and a personal
computer PC (where software was installed is MAESTRO 32) for recording data. In
order to reduce the background level of the system, the detector is cvered by shield
prepared from lead about 6 cm on all side (Figure 3.4).
Figure 3.4. Schematic view of gamma Spectrometer and electronic units
34
3.2.2. NaI (TI) Detector
The scintillation detectors are consist of scintillator material and photomultiplier
pipe connected to the materials. It can cause ionization or excitation if the ionizing
radiation interacts with scintillation materials. Scintillation light emitted by the
phosphor was collected by photomultiplier tubes, it can change to the voltage pulse
as can be shown from Figure 3.5. The obtained amplitude pulse is proportional to the
energy of the radiation. This detector can be used to count and energy discrimination.
Figure 3.5. Schematic view of NaI (Tl) detector
Iodine has high atomic number in crystal of NaI, also can be obtained the high
detection efficiency. In order to activate, usually a small amount of thallium is added
to crystal, and this new structure is named Nal (TI). In (Figure 3.6) 3" x 3" NaI (Tl)
detector is seen.
Figure 3.6. Photography of NaI (Tl) detector
35
3.2.3. Electronic units
The high voltage unit in the spectrometer is used to provide a high potential. The
preamplifier could modify voltage signal which is presenting from the detector
related with the energy is stored. It can be the pulses. the pulses divide into signals
and detect the height of pulse.
The Multi-Channel Analyzer (MCA) analyses the output signals from the amplifier.
Subsequently, each analyzed signal is converted to digital form and stocked,
according to its amplitude, in a memory channel. Each channel is characterized by its
energy and picas which can be got by the accumulation of signals.
3.2.4. Energy calibration
In order for introducing the response of radiation to the detector should be calibrated
before using a gamma-ray spectrometer. That may be done by using known the
radiation sources. The using of the gamma-ray sources which are 60Co and 137Cs, the
energy calibration of NaI (Tl) detector has been achieved. From the Figures 3.7 and
3.8, it can be shown that the decay scheme of the two our sources were used. The
energies 662, 1173 and 1332 keV of gamma rays are released from those sources can
be seen in these figures respectively.
Figure 3.7. The decay scheme of 137Cs
36
Figure 3.8. The decay scheme of 60Co
In the upper part of Figure 3.9 has been shown that the energy spectrum from the
sources which are used in our system related to the channel number. In the lower
section of figure 3.9, the related of fit energy against the channel number has shown.
Figure 3.9. Energy spectrum and related fit
3.2.5. Detection efficiency calibration
The detector performance is crucial in radiation measurement for the reason that in
the detector material, and before detection is made possible, the radiation can travel
37
large distances between interactions. The detectors efficiency is not reached 100%.
The gamma spectrometer performance depends precisely on the detection efficiency
knowledge. The latter, and as depicted in Figure 3.10, is a measure of radiation
percentage detected by a given detector from the overall yield emitted by the source.
The detection efficiency can change the volume and shape of the detector material,
absorption cross-section in the material, attenuation layers in front of the detector,
distance and position from the source to the detector. (Akkurt, 2014).
Figure 3.10. Detection efficiency of NaI (Tl) detector as a function of gamma-ray
energies for 0,5 cm distance to detector face (Akkurt, 2014).
3.3. The Linear attenuation Coefficients Measurement
Prepared composite samples have been tested in front of gamma-ray by using gamma
spectrometer in the laboratories of Suleyman Demirel University. The measurements
have been done with the energies 662, 1173 and 1332keV of gamma-rays. The
gamma-rays for those energies from 137Cs and 60Co will be obtained. For each
sample, the linear attenuation coefficients are measured using the relationship
between incoming and passing through material.
38
According to the initial intensity of gamma-ray Io passed through zero thickness of
the material is known, the linear attenuation coefficients may be obtained by the
following equation:
𝐼 = 𝐼0𝑒−𝜇𝓍 (3.1)
Where, I and Io are counted in the detector respectively, with and without the
materials (Figure 3.11). Plotting ln (Io/I) versus x would give straight line and could
be acquired from the slope value.
Figure 3.11. I and Io are measured count in detector respectively with and without
the absorber of thickness x (cm)
The intensity of incoming (Io) and passing through (I) gamma rays is obtained from
energy spectrum. It is a number of count under the spectrum peak. In (Figure 3.12)
displayed the intensity of the gamma rays with and without absorber materials for
137Cs and 60Co. From this figure could be seen that the dot line is (Io), the attenuated
gamma-ray spectrum, and full line is (I) the attenuated gamma-ray spectrum.
39
Figure 3.12. Intensity of gamma rays with and without materials for 60Co and 137C
sources
The half-value layer (HVL), which is the thickness of the transmitted density up to
half of the first density, defines the effectiveness of gamma ray shielding and the
tenth-valur layer (TVL) is the thicknesses of an absorber that will reduce the γ-
radiation to tenth of its intensity. Those are obtained as:
2lnHVL ,
10lnTVL (3.2)
The mean free path (cm) is defined as: the average distance between consecutive
interactions of gamma-ray photons with matter measures its probability of interaction
and it is given as:
𝑚𝑓𝑝 = 1
𝜇 (3.3)
40
4. RESULTS AND DISCUSSIONS
In the present work, the linear attenuation coefficients (µ) cm-1 were measured for
Rubber, Jute and Glass-Fiber (R-J-G/F) composite with different rates which is used
as absorber by using gamma spectrometer system and by using life radioactive
sources 137Cs and 60Co for the energies (662, 1173, and 1332) keV respectively.
The results are shown in Figure 4.1 where the linear attenuation coefficient µ (cm-1)
plotted as a function of gamma energy. It can be seen from this figüre that the highest
value of linear attenuation coefficient at low energy 662 keV of pure rubber in
sample R100 has been obtained while it decreases with increasing ratio of jute in
R90-J10, R80-J20, and R70-J30 respectively. It also decreases with increasing ratio
of glass-fiber in R90-GF10, R80-GF20, and R70-GF30 in composite materials
respectively.
Figure 4.2 shows the linear attenuation coefficient as a fuction of gamma energy for
R100, R90-J10, R80-J20, and R70-J30. It can be seen that the linear attenuation
cofficient decreases with increasing the energy.
Figure 4.3 shows the linear attenuation coefficient as a fuction of gamma energy for
R100, R90-GF10, R80-GF20, and R70-GF30. It is also clear from this figüre that the
linear attenuation cofficient decreases with increasing the gamma ray energy.
Figure 4.4 shows the linear attenuation coefficient as a fuction of gamma energy for
R100, R70-J10-GF20, R70-J15-GF15, and R70-J20-GF10. It is proved ones again
from this figüre that the linear attenuation cofficient decreases with increasing the
energy.
In Figur 4.5 shows that the linear attenuation coefficient as a fuction of gamma ray
energies and jute rate for all samples. It can be seen that the linear attenuation
cofficient decreases with gamma ray energies and the ratio of jute in the composite.
In Figur 4.6 shows that the linear attenuation coefficient as a fuction of gamma ray
energies and glass-fiber rate for all samples. It can be seen that the linear attenuation
cofficient decreases with gamma ray energies and increasing the ratio of glass-fiber
in the composite.
41
Figur 4.7 shows that the linear attenuation coefficient as a fuction of gamma ray
energies and jute and glass-fiber rates in samples. The energies were 662, 1173 and
1332 keV while rates were 0%, 10%, 15%, 20% for jute and 0%, 10%, 15%, 20% for
glass-fiber. As can be seen from this figure that the linear attenuation coefficient
decreases with both increasing energies and the ratio of jute and glass-fiber.
As the mfp is an important parameter in radiation dosimeter, the mfp results have
been obtained. Figure 4.8 shows the mean free path mfp (cm) as a function of energy
to the samples R100, R90-J10, R80-J20 and R70-J30. It can be seen from these
fugures that, the mean free path of R100 is 11.94 cm, 15.31 cm and 16.37 cm for the
energy of 662, 1173 and 1332 keV respectively. The mean free path of R90-J10 is
12.64 cm at the energy 662 keV, it is increases to 16.74 cm with increasing the
energy to 1173 keV, and it also increases to 17.89 cm with increasing the energy to
1332 keV. The mean free path of R80-J20 is 13.18 cm at the energy 662 keV, it is
increases to 18.71 cm with increasing the energy to 1173 keV, and it also increases to
20.45 cm with increasing the energy to 1332 keV. The mean free path of R70-J30 is
14.25 cm at the energy 662 keV, it is increases to 20.19 cm with increasing the
energy to 1173 keV, and it also increases to 21.56 cm with increasing the energy to
1332 keV.
Figure 4.9 shows the mean free path mfp (cm) as a function of energy to the samples
R100, R90-GF10, R80-GF20, and R70-GF30. From these results, it can be
concluded that the mean free path of R100 is 11.94 cm at the energy 662 keV, it is
increases to 15.31 cm with increasing the energy to 1173 keV, and it also increases to
16.37 cm with increasing the energy to 1332 keV. The mean free path of R90-GF10
is 13.3 cm at the energy 662 keV, it is increases to 16.2 cm with increasing the
energy to 1173 keV, and it also increases to 17.5 cm with increasing the energy to
1332 keV. The mean free path of R80-GF20 is 14.2 cm at the energy 662 keV, it is
increases to 17.8 cm with increasing the energy to 1173 keV, and it also increases to
18.7 cm with increasing the energy to 1332 keV. The mean free path of R70-GF30 is
15.4 cm at the energy 662 keV, it is increases to 19 cm with increasing the energy to
1173 keV, and it also increases to 20.1 cm with increasing the energy to 1332 keV.
42
Figure 4.10 shows the mean free path mfp (cm) as a function of energy to the
samples R100, R70-J10-GF20, R70-J15-GF15, and R70-J20-GF10. From these
results, it can be seen that the mean free path of R100 is 11.94 cm at the energy 662
keV, it is increases to 15.31 cm with increasing the energy to 1173 keV, and it also
increases to 16.37 cm with increasing the energy to 1332 keV. The mean free path of
R70-J10-GF20 is 13.1 cm at the energy 662 keV, it is increases to 17.1 cm with
increasing the energy to 1173 keV, and it also increases to 18 cm with increasing the
energy to 1332 keV. The mean free path of R70-J15-GF15 is 13.7 cm at the energy
662 keV, it is increases to 19.7 cm with increasing the energy to 1173 keV, and it
also increases to 20.6 cm with increasing the energy to 1332 keV. The mean free
path of R70-J20-GF10 is 14.3 cm at the energy 662 keV, it is increases to 20.9 cm
with increasing the energy to 1173 keV, and it also increases to 22.5 cm with
increasing the energy to 1332 keV. Those all shown that the mfp increases with the
increasing gamma-ray energies.
Figure 4.11 shows the gamma-ray transmission rate (%) through materials as a
function of thickness (cm) to the four samples R100, R90-J10, R80-J20 and R70-J30
at three energies 662, 1173, 1332 keV. From these results, It is clear that while a
smaller thickness of R100 is required to stop 𝛾-rays, the larger thickness is required
for R90-J10, R80-J20 and R70-J30 respectively. The HVL and TVL values for those
materials are also indicated in this figure. The same results can be said for those
values. Also, it can be seen that the HVL and TVL increase with increasing the
energy.
Figure 4.12 shows the gamma-ray transmission rate (%) through materials as a
function of thickness (cm) to the four samples R100, R90-GF10, R80-GF20, and
R70-GF30 at three energies 662, 1173, 1337 keV. From these results, It is clear that
while a smaller thickness of R100 is required to stop gamma-rays, a larger thickness
is required for R90-GF10, R80-GF20, and R70-GF30 respectively. The HVL and
TVL values for those materials are also indicated in this figure. Also, it can be seen
that the HVL and TVL increase with the increasing of energy.
43
Figure 4.13 shows the gamma-ray transmission rate (%) through materials as a
function of thickness (cm) to the four samples R100, R70-J10-GF20, R70-J15-GF15,
and R70-J20-GF10 at three energies 662, 1173, 1332 keV. From these results, It is
clear that while a smaller thickness of R100 is required to stop gamma-rays, the
larger thickness is required for R70-J10-GF20, R70-J15-GF15, and R70-J20-GF10
respectively. The HVL and TVL values for those materials are also indicated in this
figure. The same results can be said for those values. Also, it can be seen that the
HVL and TVL increase with the increasing of energy.
Figure 4.1. The relationship between 𝝁 (cm-1) and energy (keV) for all composite
samples
44
Figure 4.2. The relationship between 𝝁 (cm-1) and energy (keV) for R100, R90-J10,
R80-J20, and R70-J30
Figure 4.3. The relationship between 𝝁 (cm-1) and energy (keV) for R100, R90-
GF10, R80-GF20, and R70-GF30
45
Figure 4.4. The relationship between 𝝁 (cm-1) and energy (keV) for R100, R70-J10-
GF20, R70-J15-GF15, and R70-J20-GF10
Figure 4.5. The relationship between 𝝁 (cm-1) and jute rate
46
Figure 4.6. The relationship between 𝝁 (cm-1) and glass-fiber rate
Figure 4.7. The 𝝁 (cm-1) as a function of energy and also jute and glass-fiber rates for
R100, R70-J10-GF20, R70-J15-GF15, and R70-J20-GF10
47
Figure 4.8. The relationship between mfp (cm) and energy (keV) for R100, R90-J10,
R80-J20, and R70-J30
Figure 4.9. The relationship between mfp (cm) and energy (keV) for R100, R90-
GF10, R80-GF20, and R70-GF30
48
Figure 4.10. The relationship between mfp (cm) and energy (keV) for R100, R70-J10
GF20, R70-J15-GF15, and R70-J20-GF10
49
Figure 4.11. The relationship between transmission rate (%) and thikness (cm) for
R100, R90-J10, R80-J20, and R70-J30
50
Figure 4.12. The relationship between transmission rate (%) and thikness (cm) for
R100, R90-GF10, R80-GF20, and R70-GF30
51
Figure 4.13. The relationship between transmission rate (%) and thickness (cm) for
R100, R70-J10-GF20, R70-J15-GF15, and R70-J20-GF10
52
5. CONCLUSION
As the radiation is very important phenemone in our life it is used in a variety of
different fields. On the other hand its higher dose is hazardous for human health and
it must be protected. Shielding is the main method to be protected from radiation and
thus the development of shielding materials becomes popular for researhers. In the
recent years, there have been many studies to find new composite materials used in
the radiation shielding. For this purposes composite materials consist of the Rubber,
as the main material, Jute and Glass-Fiber for radiation shielding have been done and
ten samples have been produced. These produced materials have been tested against
gamma-ray of 662, 1173, 1332 keV energies. The measurement has shown that the
jute and glass-fiber are not important materials to shield gamma rays when we have
added them with rubber. With the increasing jute rate and glass-fiber in the
composite material, the linear attenuation coefficient is decreased. This leads that
rubber without jute and glass-fiber is more useful for shielding against gamma-rays.
Further researches should be carried out to find out more suitable shielding materials.
53
REFERENCES
Akkurt, I., Akyıldırım, H., Mavi, B., Kilincarslan, S., & Basyigit, C. (2010).
Radiation shielding of concrete containing zeolite. Radiation Measurements,
45(7), 827-830.
Akkurt, I., Altindag, R., Gunoglu, K., & Sarıkaya, H. (2012). Photon attenuation
coefficients of concrete including marble aggregates. Annals of Nuclear
Energy, 43, 56-60.
Akkurt, I., Gunoglu, K., & Arda, S. S. (2014). Detection efficiency of NaI (Tl)
detector in 511–1332 keV energy range. Science and Technology of Nuclear
Installations, 2014.
Akkurt, I., Kılıncarslan, S., Basyigit, C., Mavi, B., & Akyıldırım, H. (2009).
Investigation of photon attenuation coefficient for pumice. International
Journal of Physical Sciences, 4(10), 588-591.
Akkurt, I., Kılınçarslan Ş, Basyigit, C. (2004). The Photon Attenuation Coefficients of
Barite, Marble And limra, Süleyman Demirel Üniversitesi, Amitabat, Isparta,
Turkey,Annals of Nuclear Energy. 03/2004; 31 (5): 577-582. DOI: 10.1016 /
j.anucene.2003.07.002.
Akkurt, I., Mavi, B., Gunoglu, K., AKYLDIRIM, H., & CANAKCIC, H. (2013).
Photon Attenuation Coefficients of Iron Doped Clay at 662 keV.
ActaPhysicaPolonica, A., 123(2).
Al-Humaiqani, M. M., Shuraim, A. B., & Hussain, R. R. (2013). Effect of
Compressive Strength on gamma-Radiation Attenuation Coefficients for
High Performance Concrete. International Journal of Engineering and
Technology, 5(5), 566.
Ali, H, P,. (2015). The investigation of natural radioactivities and hazard index for
soil samples around Pshdar region in Iraq. Approval of the Graduate School
of Natural and Applied Sciences. M.Sc. Thesis in Engineering Physics
University of Gaziantep. university of gazġantep graduate school of natural
& applied sciences.
Alsarray, E., (2016). Investigation of radiation shielding properties of some
composite material. MSc thesis Fen Bilimleri Enstitusu- SDU.
Angüner, E., (2008). Gamma-ray detector array. M.sc. Thesis institute of science and
technology. Istanbul technical university.
Awagon,. (1996), Introduction to Rubber, Nippon Gomu Kyokaishi.
http://joi.jlc.jst.go.jp/JST.Journalarchive/gomu1944/69.180?from=CrossRef.
DOI: 10.2324/gomu.69.180, ISBN: 1859571506.
54
Ayma, A., (2017). Effect of Gamma Radiation on the Properties of Jute Reinforced
Polyester Matrix Composites. Journal of Textile Science & Engineering. J
Textile Sci Eng, an open access journal ISSN: 2165-8064. Volume 7. Issue 2.
100029. DOI: 10.4172/2165-8064.1000294.
Basyigit, C., Akkurt, I., Kilincarslan, S., & Akkurt, A. (2005). Investigation of
photon attenuation coefficients for marble. Journal of Radiological
Protection, 25(2), 189. ISO 690.
Canadian Nuclear Safetly. (2012), Introduction to Radiation, available on:- CNSC
Web site at nuclearsafety.gc.ca, PWGSC catalogue number CC172-
93/2012E-PDF, ISBN 978-1-100-21572-3.
Çakıroğlu, M., (2016). Investigation of radiation shielding properties of
polypropylene fiber reinforced shotcrete. Acta Physica Polonica A, 129(4),
705-706.
Domenech, H., (2016). Radiation Safety: Management and Programs. Springer.
Springer International Publishing Switzerland 2017,
http://link.springer.com/10.1007/978-3-319-42671-6. DOI: 10.1007/978-3-
319-42671-6. ISBN: 978-3-319-42669-3.
Faruk, O., Bledzki, A. K., Fink, H. P., & Sain, M., (2012). Biocomposites reinforced
with natural fibers: 2000–2010. Progress in polymer science, 37(11), 1552-
1596.
Flakus, F. N., (1982). Detecting and Measuring Ionizing Radiation- A Short History.
IAEA bulletin, 23(4), 31-36.
Gordon, R., (2011). Practical Gamma ray spectrometry, Interaction of gamma rays
with matter. Published by John Wiley & Sons, Ltd, Chichester, UK .Page 16-
36. DOI: 10.1002/9780470861981.ch2, ISBN: 9780470861981.
Harish, V., (2011). Studies on radiation shielding characteristics of polyester based
particulate polymer composites with lead oxides as fillers.
https://emergency.cdc.gov/radiation/measurement.asp.
Industry, W. F. I. M. (1983). Background information for proposed standards. EPA-
450/3-83-022a. Research Triangle Park, NC: US Environmental Protection
Agency.
Karam, Andrew, P. and Stein, P. (2009). “Radiation Basics.” Radioactivity 7–19.
Retrieved, https://books.google.com/books?id=AgWtxh7uv84C&pgis=1.
Khan, R. K., Shauddin, S. M., Dhar, S. S., & Khan, M. A. (2014). Comparative
experimental studies on the physico-mechanical properties of jute caddies
reinforced polyester and polypropylene composites. Journal of Polymer and
Biopolymer Physics Chemistry, 2(3), 55-61.
55
Kilinç, M. (2016). Determination of natural radioactivity levels in the soil in
ġahġnbey, nurdaği and ġslahiye districts of gazġantep city, M.sc.thesis in
engineering physics university of gazġantep. Graduate school of natural &
applied sciences.
Knoll, G. F., (2010). Radiation detection and measurement. John Wiley & Sons.
Lee, M. J., & Rahimifard, S., (2012). An air-based automated material recycling
system for postconsumer footwear products. Resources, Conservation and
Recycling, 69, 90-99.
Mahdi, K. H., Ahmed, Z. S., & Mkhaiber, A. F. (2017). Calculation and Study of
Gamma ray Attenuation Coefficients for Different Composites. Ibn
AL-Haitham Journal For Pure and Applied Science, 25(3), 133-141.
Medhat, M. E., (2009). Gamma-ray attenuation coefficients of some building
materials available in Egypt. Annals of Nuclear Energy, 36(6), 849-852.
Mosiewicki, M. A., Aranguren, M. I., Curvelo, A. A. S., & Borrajo, J. (2007). Effect
of natural rubber on wood‐reinforced tannin composites. Journal of applied
polymer science, 105(4), 1825-1832.
National Research Council (US). (1980). Committee on the Biological Effects of
Ionizing Radiations, & United States. Environmental Protection Agency.
Office of Radiation Programs. (1980). The Effects on Populations of
Exposure to Low Levels of Ionizing Radiation, (Vol. 3095). National
Academy Press.
Parlar, Z., Samankan, S., & Temiz, V. (2015). The Effect of Counter-face Roughness
on the Tribological Behavior of Filled and Unfilled PTFE. Automation, 609.
Sathishkumar, T. P., Satheeshkumar, S., & Naveen, J. (2014). Glass fiber-reinforced
polymer composites–a review. Journal of Reinforced Plastics and
Composites, 33(13), 1258-1275.
Shauddin, S. M., Shaha, C. K., & Khan, M. A. (2014). Effects of Fiber Inclusion and
γ Radiation on Physico-mechanical Properties of Jute Caddies Reinforced
Waste Polyethylene Composite. Journal of Polymer and Biopolymer Physics
Chemistry, 2(4), 91-97.
Silva, M. A. G., Wolf, U., Heinicke, F., Bumann, A., Visser, H., & Hirsch, E. (2008).
Cone-beam computed tomography for routine orthodontic treatment
planning: a radiation dose evaluation. American Journal of Orthodontics and
Dentofacial Orthopedics, 133(5), 640-e1.
Smith, B. T., (2010). Introduction to radioactivity and radioactive decay.
Sudev, L. J. (2015). Effect of Gamma Irradiation on Mechanical Properties of
Natural Fibers Reinforced Hybrid Composites.
56
Türkmen, İ., Özdemir, Y., Kurudirek, M., Demir, F., Simsek, Ö., & Demirboğa, R.
(2008). Calculation of radiation attenuation coefficients in Portland cements
mixed with silica fume, blast furnace slag and natural zeolite. Annals of
Nuclear Energy, 35(10), 1937-1943.
Wallenberger, F. T., Watson, J. C., & Li, H. (2001). Glass fibers. Materials Park,
OH: ASM International, 2001., 27-34.
Wrixon, A. D., Barraclough, I., & Clark, M. J. (2004). Radiation, people and the
environment. the IAEA Division of Public Information, IAEA, 54.
Yildiz, F., Parlar, A. G., Parlar, Z., & Bakkal, M. (2017). Properties of Sound Panels
Made from Recycled Footwear Treads. Acta Physica Polonica, A., 132(3).
57
CURRICULUM VITAE
Name and Surname : Abdlhamed Faaq Abdlhamed ABDLHAMED
Birth date: Iraq- Anbar, 1988
Sex: Male
Marital status: Single
Languages: English and Turkish (A2)
E-mail : [email protected]
Educational Status
High School: AL-Anbar, ANNA School, 2006
Bachelor's degree: University of Anbar, College of Education for Pure Sciences
Department: Physics, 2010
Professional Experience :
Worked in schools of Iraqi Sunni Endowment Diwan as a lecturer between
2010 – 2011.
Teacher of Physics in a Secondary School in The Ministry of Education from
2011 to till now.
Publications :
Abdlhamed, A., Günoğlu, K., Parlar, Z., Akkurt, İ. (2017). “Gamma-Ray Shielding
Properties of Some Composite Material”. The 4th International Conference on
Computational and Experimental Science and Engineering (ICCESEN-2017)
Antalya – Turkey.
58
ÖZGEÇMİŞ
Adı Soyadı: Abdlhamed Faaq Abdlhamed ABDLHAMED
Doğum yeri - tarihi: Anbar – Irak, 1988
Cinsiyeti: Erkek
Medeni durumu: Bekar
Yabancı dili: İngilizce ve Türkçe (A2)
E-posta: [email protected]
Eğitim Durumu
Yüksekokul: AL-Anbar, ANNA Okulu, 2006
Üniversite: Anbar Üniversitesi, Eğitim Fakültesi
Bölüm: Fizik, 2010
Mesleki Tecrübe
Sünnî vakıf okullarında 2010 - 2011 staj öğretmenliği yaptım.
Millî Eğitim Bakanlığı'nda 2011 yılından bu yana bir orta öğretim okulunda
fizik öğretmeni olarak çalışmaktayım.
Yayınlar
Abdlhamed, A., Günoğlu, K., Parlar, Z., Akkurt, İ. (2017). “Gamma-Ray Shielding
Properties of Some Composite Material”. The 4th International Conference on
Computational and Experimental Science and Engineering (ICCESEN-2017)