tbooth wireless tb432 scarborough town …krownretail.com/new/pdf/tboothstcbidset.pdf · pnt...

26
TBOOTH WIRELESS TB432 SCARBOROUGH TOWN CENTRE TITLE SHEET A0.0 DG AS SHOWN UNIT 758, 300 Borough Drive SCARBOROUGH TOWN CENTRE Scarborough, Ontario DESCRIPTION DRAWING TITLE PROJECT SHEET NO. SCALE: DATE: CHECKED BY: DRAWN BY: PROJECT NO.: BY JOHN E. GUSTAVSON ARCHITECT INC. USE OR REPRODUCTION PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION. THE GENERAL CONTRACTOR SHALL REVIEW THE DOCUMENTS FOR CONFORMANCE OF CODES AND BYLAWS AND SHALL ADVISE THE ARCHITECT OF ANY DISCREPANCIES HE MAY NOTE. THE GENERAL CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND REPORT ALL ERRORS AND OMISSIONS TO THE DESIGNER, DO REVISION NO DATE NOT SCALE THE DRAWINGS. ALL RIGHTS RESERVED. PROPERTY OF BY ISSUED FOR NO DATE 16224 DC Unit 758, 300 Borough Drive, Scarborough, Ontario SCARBOROUGH TOWN CENTRE ISSUED FOR TENDER DG ISSUED FOR COORDINATION 1 01/16/17 January 27, 2017 JOHN E. GUSTAVSON ARCHITECT 4th FLOOR - 576 SEYMOUR ST., VANCOUVER, BC, CANADA V6B 3K1 P: 604-687-2511 F: 604-687-4203 www.gwa.ca BW ISSUED FOR LANDLORD REVIEW 2 01/20/17 BW ISSUED FOR BUILDING PERMIT 3 01/27/17 BW ISSUED FOR TENDER 4 04/03/17

Upload: buithuan

Post on 22-Jul-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

TBOOTH WIRELESS TB432

SCARBOROUGH TOWN CENTRE

TITLE SHEET

A0.0

DG

AS SHOWN

UN

IT

7

58

, 3

00

B

oro

ug

h D

rive

SC

AR

BO

RO

UG

H

TO

WN

C

EN

TR

E

Sca

rb

oro

ug

h, O

nta

rio

DESCRIPTION

DRAWING TITLE

PROJECT

SHEET NO.

SCALE:

DATE:

CHECKED BY:

DRAWN BY:

PROJECT NO.:

BY

JOHN E. GUSTAVSON ARCHITECT INC.

USE OR REPRODUCTION PROHIBITED

WITHOUT PRIOR WRITTEN PERMISSION.

THE GENERAL CONTRACTOR SHALL

REVIEW THE DOCUMENTS FOR

CONFORMANCE OF CODES AND

BYLAWS AND SHALL ADVISE THE

ARCHITECT OF ANY DISCREPANCIES HE

MAY NOTE. THE GENERAL CONTRACTOR

SHALL CHECK AND VERIFY ALL

DIMENSIONS AND REPORT ALL ERRORS

AND OMISSIONS TO THE DESIGNER, DO

REVISIONNO DATE

NOT SCALE THE DRAWINGS.

ALL RIGHTS RESERVED. PROPERTY OF

BYISSUED FORNO DATE

16224

DC

Unit 758, 300 Borough Drive, Scarborough, Ontario

SCARBOROUGH

TOWN CENTRE

ISSUED FOR TENDER

DGISSUED FOR COORDINATION101/16/17

January 27, 2017

JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,

VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203

www.gwa.ca

BWISSUED FOR LANDLORD REVIEW201/20/17

BWISSUED FOR BUILDING PERMIT301/27/17

BWISSUED FOR TENDER 404/03/17

JOHN E. GUSTAVSON ARCHITECT

4th Floor - 576 Seymour Street

Vancouver, BC V6B 3K1

Tel: 604-687-2511

Fax: 604-687-4203

Contact: David Cheung

Email: [email protected]

A0.0 TITLE SHEET

A1.0 COVER SHEET

A2.0 DEMOLITION PLAN

A2.1 CONSTRUCTION PLAN

A2.2 FIXTURE PLAN

A2.3 FINISHES PLAN

A2.4 POWER AND DATA PLAN

A3.0 WALL SECTIONS

A4.0 INTERIOR ELEVATIONS

A4.1 INTERIOR ELEVATIONS

A6.0 DEMOLITION REFLECTED CEILING PLAN

A6.1 REFLECTED CEILING PLAN

MW-0.0 MILLWORK COVER SHEET

MW-1.0 MILLWORK DETAILS

MW-2.0 MILLWORK DETAILS

MW-3.0 MILLWORK DETAILS

MW-4.0 MILLWORK DETAILS

MW-5.0 MILLWORK DETAILS

MW-6.0 MILLWORK DETAILS

MW-7.0 MILLWORK DETAILS

MW-8.0 MILLWORK DETAILS

DRAWING LIST

JOHN E. GUSTAVSON ARCHITECT

4TH FLOOR, 576 SEYMOUR STREET

VANCOUVER, BC V6B 3K1

ONTARIO BUILDING CODE 2012 PART 3 [DIV]

TENANT IMPROVEMENT FOR UNIT 758

2 STOREYS ABOVE GRADE

REQUIRED, PROVIDEDSPRINKLERED BUILDING

REQUIREDSTANDPIPE 3.2.9.

REQUIRED (EXITS AND ACCESS TO EXITS)EMERGENCY LIGHTING 3.2.7.3

BY SF OF BUILDINGOCCUPANT LOAD

TABLE 3.1.17.1.

BY DESIGN OF BUILDING

GROUP E, MERCHANTILE

UNIT 758, 300 BOROUGH DRIVE, SCARBOROUGH, ONTARIO, M1P 4P5

CONSTRUCTION TYPE: NON-COMBUSTIIBULE CONSTRUCTION, SPRINKLERED.

FLOOR ASSEMBLIES: FIRE SEPARATION WITH A FIRE-RESISTANCE RATING NOT LESS

THAN 2 HRS.

MEZZANINES: FIRE-RESISTANCE RATING NOT LESS THAN 1 HR.

LOADBEARING WALLS, COLUMNS AND ARCHES: SHALL HAVE FIRE-RESISTANCE

RATING NOT LESS THAN THAT REQURIED FOR THE SUPPORTED ASSEMBLY.

CODE ANALYSIS

ONTARIO BUILDING CODE 2012

30 MINUTES REQUIREDEMERGENCY POWER FOR LIGHTING 3.2.7.4

ARCHITECTURAL

CONSULTANT LIST

FIRM NAME

APPLICABLE CODE

CIVIC ADDRESS

PROJECT DESCRIPTION

MAJOR OCCUPANCY

NUMBER OF STOREYS

3.1.2.1.(1)

PERMITTED CONSTRUCTION

NOT APPLICABLENUMBER OF STREETS (FIRE ROUTES)

GROUP E, ANY HEIGHT, ANY AREA, SPRINKLERED 3.2.2.57.BUILDING CLASSIFICATION

3.2.5.13.

3.2.2.57.

NON-COMBUSTIBLEACTUAL CONSTRUCTION 3.2.2.57.

REQUIRED, PROVIDED 3.2.4.1FIRE ALARM

ADEQUATE 3.2.5.7.FIRE FIGHTING WATER SUPPLY

NO 3.2.6.HIGH BUILDING

REQUIRED

ACCESS PROVIDED TO AREAS TO WHICH THE PUBLIC IS ADMITTED

ARCHITECTURAL

3.8.

BARRIER-FREE DESIGN:

NO

AREA OF PROJECT

RETAIL AREA - 840 SF / 39.8 SF = 21.1

STORAGE AREA - 110 SF / 301.4 SF = 0.36

OCCUPANCY LOAD: 22 PERSONS (AREA OF PROJECT ONLY)

3.3.1.2, 3.3.1.19HAZARDOUS SUBSTANCES

TB432

TBOOTH WIRELESS

SCARBOROUGH

TOWN CENTRE

UNIT 758, 300 BOROUGH DRIVE

SCARBOROUGH, ONTARIO

91.4 SM (984.0 SF) AT UNIT 758

BUILDING AREAEXISTING (NO CHANGE)

MECHANICAL

ELECTRICAL

TBOOTH WIRELESS

UNIT 758

PROJECT

NORTH

TR

UE

NO

RT

H

1.4.1.2. [A] & 3.2.1.1.

OXFORD PROPERTIES GROUP

Royal Bank Plaza, North Tower

200 Bay Street, Suite 900

Toronto, ON M5J 2J2

Tel: 416-868-3710

Cel: 416-906-4283

Contact: Alana de Haan

Email: [email protected]

OWNER

GLENTEL INC.

8501 Commerce Court

Burnaby, BC V5A 4N3

Tel: 604-415-6538

Fax: 604-415-6515

Contact: Adrian Ching

Email: [email protected]

LANDLORD

SNC-LAVALIN INC.

235 Lesmill Road

Toronto, ON M3B 2V1

Tel: 416-445-8255

Fax: 416-445-7885

Contact: Co Tran

Email: [email protected]

MECHANICAL & ELECTRICAL

AFF ABOVE FINISHED FLOOR

AL, ALUM. ALUMINUM

BLDG BUILDING

CG CORNER GUARD

CJ CONTROL JOINT

CLA CLEAR ANODIZED

CLR CLEAR FINISH

CLG CEILING

CMU CONCRETE MASONRY UNIT

CT CERAMIC TILE

C/W COMPLETE WITH

CONC CONCRETE

DWG DRAWING

DIA (Ø) DIAMETER

EA EACH

EJ EXPANSION JOINT

ELEC ELECTRICAL

ELEV ELEVATION

EQ EQUAL

EX EXISTING

EXT EXTERIOR

FD FLOOR DRAIN

FIN FINISH

FRR FIRE RESISTANCE RATING

GA GAUGE

GR GRADE

GWB GYPSUM WALL BOARD

GC GENERAL CONTRACTOR

H/C HANDICAPPED

HM HOLLOW METAL

MAX MAXIMUM

MDF MEDIUM DENSITY FIBERBOARD

MECH MECHANICAL

MIN MINIMUM

MTL METAL

N/A NOT APPLICABLE

NIC NOT IN CONTRACT

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OH OVERHEAD

PS PRESSED STEEL

PNT PAINTED

PLAM PLASTIC LAMINATE

PLY PLYWOOD

PT PRE-TREATED

RB RUBBER BASE

REQ'D REQUIRED

RD ROOF DRAIN

STRUCT STRUCTURAL

SPEC SPECIFICATIONS

SS STAINLESS STEEL

SF, SQ.FT. SQUARE FEET

TYP TYPICAL

T/O TOP OF

U/S UNDER SIDE

VIF VERIFY IN FIELD

WC WATER CLOSET

WD WOOD

WT WEIGHT

LIST OF ABBREVIATIONS

NON-COMBUSTIBLE CONSTRUCTION

FULLY SPRINKLERED BUILDING

1. REFER TO GLENTEL'S INVITATION TO BIDDERS FOR

SUMMARY OF SCOPE OF WORK

2. G.C. MILLWORK PACKAGE INCLUDED WITH TENDER

SET IS FOR INFORMATION AND COORDINATION ONLY.

GC TO REVIEW REQUIRED LOCATIONS FOR ALL

POWER AND DATA CONNECTION POINTS REQUIRED

IN MILLWORK AND COORDINATE OUTLETS

ACCORDINGLY. REFER TO INVITATION TO BID,

AND/OR SCOPE OF WORK SUMMARY TO CONFIRM IF

THE OWNER WOULD LIKE A SEPARATE BID PRICE TO

COMPLETE THE REQUIRED MILLWORK PACKAGE.

3. DURING TENDER PERIOD, QUESTIONS RELATED TO

ARCHITECTURAL, G.C. TO CONTACT TO GWA AND

QUESTIONS RELATED TO MILLWORK, CONTACT

SHIKITANI LECROIX DESIGN.

4. CONSTRUCTION SHALL COMPLY WITH ALL

APPLICABLE STANDARD CONDITIONS AND CODES AS

PER OBC 2012 OR AUTHORITY HAVING JURISDICTION.

5. G.C. TO PROVIDE SIGNED AND SEALED SHOP

DRAWINGS FROM ENGINEER REGISTERED IN THE

PROVINCE OF ONTARIO FOR MODIFIED SPRINKLER

SYSTEM TO SUIT NEW FIXTURE AND EQUIPMENT

PLAN.

6. DURING CONSTRUCTION, ACCESS SHALL BE

PROVIDED TO ALL AREA OF THE SITE COMPLETELY

AROUND STRUCTURES.

7. CONTRACTOR IS RESPONSIBLE FOR OBTAINING

OCCUPANCY PERMIT AT THE TIME OF SUBSTANTIAL

COMPLETION.

8. TEMPORARY CONSTRUCTION HOARDING SHALL BE

MADE SUBJECT TO THE REVIEW AND APPROVAL OF

THE LOCAL BUILDING DEPT. AND LANDLORD DESIGN

GUIDELINES.

9. MEASURE SHALL BE TAKEN TO CONTAIN ALL

CONSTRUCTION DEBRIS, TRASH AND MATERIALS

ON-SITE UNTIL DISPOSAL OFF-SITE CAN BE

ARRANGED.

10.PROVIDE FIRE SAFETY PLAN TO THE SATISFACTION

OF THE LOCAL FIRE AUTHORITY.

8. G.C. TO FACILITATE ALL PERMIT REQUIREMENT FOR

ANY OWNER SUPPLIED ITEMS IF REQUIRED.

9. PRIOR TO OBTAINING OCCUPANCY AND FINAL

INSPECTION FROM THE CITY, COORDINATING

REGISTERED PROFESSIONAL ON RECORD WILL

INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING

ITEMS BEFORE TURNING OVER THEIR FINAL

SCHEDULES:

- DEMONSTRATION OF A LIFE SAFETY SYSTEM,

INCLUDING OBSERVATION OF A FIRE ALARM SYSTEM,

SUCH AS A PULL TEST, TEST OF EMERGENCY

SYSTEMS, EXIT SIGNS AND EMERGENCY LIGHTING

ETC.

- CONTRACTOR TO SUBMIT ALL SUPPORTING

DOCUMENTATION AND SCHEDULES.

- FIRE ALARM VERIFICATION REPORT AND ULC

MONITORING

- FIRE STOPPING LETTER FROM CONTRACTOR

- DRAFT STOP INSTALLATION DRAWING AND LETTER

FROM CONTRACTOR

- INSTALLATION AND NEW FIRE SAFETY PLAN AND

CONFIRMATION/VALIDITY OF ALL FIRE EXTINGUISHER

AND PULL STATION LOCATIONS.

CONSTRUCTION NOTES

Upper

Level

1.4.1.2. [A]

M-1 MECHANICAL LEGEND, SCHEDULES AND SPECS.

M-2 MECHANICAL PLAN

E1 ELECTRICAL SPECIFICATION AND DETAILS

E2 ELECTRICAL LIGHTING LAYOUT

E3 ELECTRICAL POWER LAYOUT

EXP SERVICES INC.

220 Commerce Valley Drive West, Suite 500

Markham, ON L3T 0A8

Tel: 905-695-3217

Fax: 905--695-0167

Contact: Darrell Sakauye

Email: [email protected]

STRUCTURAL

COVER SHEET

A1.0

DG

AS SHOWN

UN

IT

7

58

, 3

00

B

oro

ug

h D

rive

SC

AR

BO

RO

UG

H

TO

WN

C

EN

TR

E

Sca

rb

oro

ug

h, O

nta

rio

DESCRIPTION

DRAWING TITLE

PROJECT

SHEET NO.

SCALE:

DATE:

CHECKED BY:

DRAWN BY:

PROJECT NO.:

BY

JOHN E. GUSTAVSON ARCHITECT INC.

USE OR REPRODUCTION PROHIBITED

WITHOUT PRIOR WRITTEN PERMISSION.

THE GENERAL CONTRACTOR SHALL

REVIEW THE DOCUMENTS FOR

CONFORMANCE OF CODES AND

BYLAWS AND SHALL ADVISE THE

ARCHITECT OF ANY DISCREPANCIES HE

MAY NOTE. THE GENERAL CONTRACTOR

SHALL CHECK AND VERIFY ALL

DIMENSIONS AND REPORT ALL ERRORS

AND OMISSIONS TO THE DESIGNER, DO

REVISIONNO DATE

NOT SCALE THE DRAWINGS.

ALL RIGHTS RESERVED. PROPERTY OF

BYISSUED FORNO DATE

16224

DC

Unit 758, 300 Borough Drive, Scarborough, Ontario

SCARBOROUGH

TOWN CENTRE

ISSUED FOR TENDER

DGISSUED FOR COORDINATION101/16/17

January 27, 2017

JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,

VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203

www.gwa.ca

BWISSUED FOR LANDLORD REVIEW201/20/17

BWISSUED FOR BUILDING PERMIT301/27/17

BWISSUED FOR TENDER 404/03/17

SCALE:

1

LOCATION MAP

N.T.S. SCALE:

2

MALL UNIT PLAN

N.T.S.SCALE:

1

LOCATION MAP

N.T.S. SCALE:

2

MALL UNIT PLAN

N.T.S.

NORTH NORTH

A

FE

12'-4"

8'-0

"4

8'-1

0"

23

'-9

"

1

7

'

-

3

"

15'-0"

2

3

'

-

3

1

/

2

"

1'-6"

7"

6'-4

"1

'-4

"

EXISTING FIRE HOSE CABINET TO REMAIN

EXISTING GRILLE ENCLOSURE AND POCKET DOOR

TO BE REMOVED. PREPARE REMAINING

SURFACES FOR NEW STOREFRONT

CONSTRUCTION AS PER DWG. A2.1

ANY WORK AFFECTING LL BASE BUILDING, SUCH AS

SPRINKLER SYSTEM, HVAC SYSTEM,ROOF WORK, TILE

WORK OUTSIDE OF LEASED AREA OR ELECTRICAL WORK

OUTSIDE OF LEASED AREA WILL BE REQUIRED TO BE

PERFORMED BY A LL DESIGNATED OR LL APPROVED

CONTRACTOR AND BE ENGAGED BY THE TENANT.

LEASE LINE

EXISTING GRILLE DOOR AND TRACK TO BE

REMOVED.

EXISTING DEMISING CAP TO REMAIN AND

PROTECTED TO BE IN LIKE NEW CONDITION.

PATCH AND REPAIR AS REQUIRED TO MATCH

EXISTING (TYP. BOTH SIDES)

REMOVE EXISTING STOREFRONT PARTITIONS AND

MILLWORK. PREPARE REMAINING SURFACES FOR

RENEW STOREFRONT CONSTRUCTION AS PER

DWG. A2.1

SAW CUT TRENCH IN EXISTING CONCRETE TOPPING.

REFER TO ELECTRICAL AND DWG. 2/A2.4

SAW CUT TRENCH IN EXISTING CONCRETE

TOPPING. REFER TO ELECTRICAL AND DWG. 2/A2.4

SAW CUT TRENCH IN EXISTING CONCRETE

TOPPING. REFER TO ELECTRICAL AND DWG. 2/A2.4

COORDINATE WITH OXFORD'S STRUCTURAL

ENGINEER FOR SCANNING REQUIREMENT. AVOID

ANY REBAR IN CONCRETE.

ALL EXISTING MILLWORK AND FURNITURE TO BE REMOVED

EXCEPT AS NOTED. PATCH AND REPAIR SURROUNDING

AREA AS REQUIRED TO MAKE READY FOR NEW FINISHES &

FIXTURES. ALL NEW & RE-PURPOSED MILLWORK FIXTURES

TO BE FURNISHED BY OWNER, INSTALLED BY GC.

ADDITIONAL DEMO NOTES:

· REFER TO DWG. A6.0 DEMOLITION REFLECTED

CEILING PLAN FOR ADDITIONAL DEMOLITION SCOPE.

· CONTRACTOR TO VERIFY ALL SITE CONDITIONS &

REPORT ANY DISCREPANCIES TO CONSULTANTS

PRIOR TO CONSTRUCTION.

· ALL CONSTRUCTION WASTE MATERIALS &

CARDBOARD MUST BE RECYCLED.

· BASE BUILDING SLAB SHALL BE BROUGHT BACK TO

SMOOTH TROWELED SINGLE PLAIN CONCRETE.

ALL REDUNDANT WIRING TO BE REMOVED BY ELECTRICAL

CONTRACTOR AS REQ'D. (TYP.)

EXISTING TRANSFORMERS AND ELECTRICAL

PANELS TO REMAIN. REFER TO ELECTRICAL

EXISTING FLOOR FINISH AND RUBBER BASE AT

STORAGE ROOM TO BE REMOVED. PATCH, REPAIR

AND PREP FLOOR TO RECEIVE NEW FLOOR FINISH

AS REQUIRED

EXISTING PARTITION TO REMAIN. REMOVE

ALL EQUIPMENT, FIXTURE AND MILLWORK

EXISTING DOOR, FRAME AND DOOR HARDWARE

TO REMAIN

EXISTING FLOOR FINISHES & BASEBOARDS

TO BE REMOVED. G.C. TO MAKE GOOD

SURROUNDING SURFACES & LEVEL FLOOR

TO RECEIVE NEW FLOOR FINISHES AS PER

DWG. A2.4

EXISTING DEMISING WALLS -

G.C. TO ENSURE ALL REQUIRED FIRE RATINGS ARE

MAINTAINED (TYPICAL BOTH SIDES)

EXISTING BULKHEAD CEILING, ALL TRACK,

RECESSED LIGHTING AND PENDANT FIXTURE

TO BE REMOVED UNLESS OTHERWISE NOTED.

REFER TO ELECTRICAL DRAWINGS AND DWG.

A6.0 FOR ADDITIONAL DEMOLITION SCOPE ON

REFLECTED CEILING PLAN.

REMOVE ALL EQUIPMENT, SIGNAGE AND FIXTURES

THROUGHOUT. REMAINING SURFACES TO BE

MADE READY FOR NEW FINISHES AND STORE

FIXTURES AS PER DWG. A2.2

EXISTING ROUND COLUMN CLADDING TO BE

REMOVED

ALL CORING / TRENCHING OF SLAB MUST BE IN

ACCORDANCE TO THE GUILDLINES ISSUED BY

LANDLORD, AND LOCATIONS MUST BE APPROVED BY

STRUCTURAL ENGINEER. SCAN SLAB PRIOR TO CORING

AND TRENCHING. NOTIFY MALL OPERATIONS PRIOR TO

WORK.

EXISTING POWER POLE TO BE REMOVED, TYPICAL.

REFER TO ELECTRICAL

REMOVE ALL SHELVING THROUGHOUT. PATCH

AND REPAIR GWB SURFACES AS REQUIRED FOR

NEW FINISHES AND NEW SHELVING.

EXISTING ELECTRICAL DEVICES IN THE STORAGE

AREA TO REMAIN. UNLESS OTHERWISE NOTES.

EXISTING POWER POLE AND ASSOCIATED CABLES

TO BE REMOVED, TYPICAL. REFER TO ELECTRICAL

CHAT'R FIXTURE TO BE REMOVED AND STORED

FOR REINSTALLATION

FIXTURE TO BE REMOVED AND STORED FOR

REINSTALLATION

APPLE FIXTURE TO BE REMOVED

AND STORED FOR REINSTALLATION

SAMSUNG FIXTURE TO BE REMOVED AND STORED

FOR REINSTALLATION

GOOGLE FIXTURE TO BE REMOVED AND STORED

FOR REINSTALLATION

EXISTING SECURITY CAMERA RELOCATE TO

COORDINATE WITH FIXTURE

REFER TO ELECTRICAL DWGS.

EXISTING FIRE EXTINGUISHER AND ALARM

KEYPAD TO TO REMAIN

6

'

-

1

"

2

'

-

1

"

7'-9 1/2"

2'-6

"

3'-7 1/2"

6

'

-

4

1

/

2

"

72°

4'-8"

3

'-

8

"

7

'-

1

"

6'-9

"

8

1

/

2

"

7'-5

1

/2

"

COORDINATE ENTRY ACCESS WITH LL HOARDING.

PROVIDE SHOE MATS AND WIPES TO PREVENT DUST AND

DIRT FROM ENTERING MALL SPACE.

G.C. TO ENSURE NEW CONCRETE

TOPPING WITHIN TENANT SPACE

LINE WITH MALL FEATHER POINT

6

"

6"

6"

6

1

/

2

"

6"

6

"

2'-0

"

1. CONTRACTOR MUST VISIT THE SITE, EXAMINE ALL EXISTING CONDITIONS, TENDER DOCUMENTS,

DRAWINGS AND SPECIFICATIONS, AND MAKE NECESSARY ALLOWANCES IN THE TENDER PRICE FOR

REMOVAL.

2. REPORT ANY DISCREPANCIES IN WRITING TO THE DESIGNER IMMEDIATELY.

3. ALL WORK SHALL CONFORM TO ALL LOCAL, CITY, PROVINCIAL CODES AND BY-LAWS IN THE

JURISDICTION WHERE THE PROJECT IS LOCATED.

4. AS OUTLINED AND INDICATED ON PLANS, REMOVE ALL LIGHT FIXTURES, PERIMETER WALL

TREATMENTS, HARDWARE, CAP OFF WATER DRAINS AND VENT PIPES AS REQUIRED, DISCONNECT

AND SAFELY CAP ELECTRICAL FIXTURES/EQUIPMENT AND WIRING AS REQUIRED.

5. REMOVE AND SAFELY CAP ALL REDUNDANT EXISTING WIRING AND ELECTRICAL FIXTURES.

6. OUTLETS NOT BEING USED TO BE DISCONNECTED AND CAPPED OFF.

7. ALL PLUMBING, ELECTRICAL, AND MECHANICAL WORK TO FOLLOW UNDER SEPARATE PERMIT;

EXISTING SITE AND SITE CONDITIONS TO BE REVIEWED THOROUGHLY PRIOR TO WORK BEING

STARTED.

8. THESE DRAWINGS HAVE BEEN GENERATED FROM PREVIOUS EXISTING DRAWINGS AND SITE

DIMENSIONS - CONTRACTOR MUST VERIFY ALL DIMENSIONS AND LAYOUTS PER THESE DRAWINGS,

AND NOTIFY THE CONSULTANTS OF ANY DISCREPANCIES.

9. ALL ABOVE WORK NOTED AS WELL AS WORK DOCUMENTED TO BE COMPLETED PER LOCAL CODES

AND BYLAWS.

10. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING EXISTING LL DEMISING CAPS IN GOOD

CONDITION ONCE CONSTRUCTION IS COMPLETE. GC TO REPLACE WITH NEW SHOULD CAP BE

DAMAGED.

11. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL LABOUR, MATERIALS,

AND SUPERVISION NECESSARY TO COMPLETE THE WORK AS SHOWN OR NOTED ON THE

DRAWINGS. IT SHALL BE UNDERSTOOD THAT ALL WORK PERFORMED SHALL BE DONE BY A

LICENSED CONTRACTOR IN A WORKMANLIKE MANNER. SAID CONTRACTOR SHALL MEET ALL

REQUIREMENTS SET FORTH BY ANY LOCAL ORDINANCE AND GOVERNING AUTHORITIES. THE

CONTRACTOR SHALL KEEP ALL AREAS OF WORK CLEAN FROM DEBRIS AT ALL TIMES, AND SAID

AREAS SHALL BE LEFT BROOM CLEAN AT THE END OF EACH WORKING DAY. CONTRACTOR SHALL

GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT

LESS THAN ONE YEAR FROM THE DATE OF ACCEPTANCE. CORRECTION OF ANY DEFECTS SHALL BE

COMPLETED WITHOUT ADDITIONAL CHARGE, AND SHALL INCLUDE REPLACEMENT OR REPAIR OF

ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY.

GENERAL DEMOLITION NOTES

AS PER OXFORD LANDLORD DESIGN GUIDELINES.

HOARDING NOTE

AS PER OXFORD LANDLORD DESIGN GUIDELINES.

HOARDING NOTE

DEMOLITION PLAN

A2.0

DG

AS SHOWN

SCALE:

1

DEMOLITION PLAN

3/8" = 1'-0"

UN

IT

7

58

, 3

00

B

oro

ug

h D

rive

SC

AR

BO

RO

UG

H

TO

WN

C

EN

TR

E

Sca

rb

oro

ug

h, O

nta

rio

DESCRIPTION

DRAWING TITLE

PROJECT

SHEET NO.

SCALE:

DATE:

CHECKED BY:

DRAWN BY:

PROJECT NO.:

BY

JOHN E. GUSTAVSON ARCHITECT INC.

USE OR REPRODUCTION PROHIBITED

WITHOUT PRIOR WRITTEN PERMISSION.

THE GENERAL CONTRACTOR SHALL

REVIEW THE DOCUMENTS FOR

CONFORMANCE OF CODES AND

BYLAWS AND SHALL ADVISE THE

ARCHITECT OF ANY DISCREPANCIES HE

MAY NOTE. THE GENERAL CONTRACTOR

SHALL CHECK AND VERIFY ALL

DIMENSIONS AND REPORT ALL ERRORS

AND OMISSIONS TO THE DESIGNER, DO

REVISIONNO DATE

NOT SCALE THE DRAWINGS.

ALL RIGHTS RESERVED. PROPERTY OF

BYISSUED FORNO DATE

16224

DC

Unit 758, 300 Borough Drive, Scarborough, Ontario

SCARBOROUGH

TOWN CENTRE

ISSUED FOR TENDER

DGISSUED FOR COORDINATION101/16/17

January 27, 2017

JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,

VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203

www.gwa.ca

BWISSUED FOR LANDLORD REVIEW201/20/17

BWISSUED FOR BUILDING PERMIT301/27/17

BWISSUED FOR TENDER 404/03/17

NORTH

AutoCAD SHX Text
FHC

A

FE

12'-4"

8'-0

"4

8'-1

0"

23

'-9

"

1

7

'

-

3

"

15'-0"

2

3

'

-

3

1

/

2

"

7"

1

'

-

6

"

2

A4.0

2

A4.1

1

A4.1

1

A4.0

3

A

3

.

0

STORAGE

( B.O.H. )

110 SQ.FT.

RETAIL

840 SQ.FT.

EXISTING PARTITION TO REMAIN

ALL DIMENSIONS TO BE CONFIRMED ON SITE

PRIOR TO CONSTRUCTION

REFER TO DWG. A4.0 FOR STOREFRONT

DETAILS AND SECTIONS

ALL DIMENSIONS & SITE CONDITIONS TO BE

VERIFIED BY GC

WHERE APPLICABLE SCAN SLAB PRIOR TO

ANY TRENCHING OR CORING AND NOTIFY

MALL OPERATIONS PRIOR TO WORK

EXISTING DEMISING WALLS -

G.C. TO ENSURE ALL REQUIRED FIRE RATINGS ARE

MAINTAINED (TYPICAL BOTH SIDES)

EXISTING DEMISING CAP TO REMAIN, TYPICAL

BOTH SIDES. PATCH AND REPAIR AS REQUIRED

TO MATCH EXISTING.

G.C. TO PROVIDE STEEL STUD FURRED OUT

PARTITION C/W PLYWOOD SHEATHING ON

EXTERIOR SURFACE. MILLWORK CONTRACTOR TO

PROVIDE MILLWORK FINISH TO BE SECURED TO

PARTITION. REFER TO WALL PARTITION

SCHEDULE AND DWG. A3.0 FOR DETAILS.

LEASE LINE

NEW STOREFRONT 1/2" TEMPERED GLASS C/W

U-CHANNEL AT T/O GLASS TO BE SECURELY

FASTENED TO STRUCTURAL SUPPORT WITHIN

BULKHEAD. APPLY VINYL STICKER AT THE TOP OF

GLASS. OPAQUE PINK TO MATCH PT-2 TO RUN

CLEAR OVER A 2'-0" LENGTH.

NEW GRILLE ENCLOSURE DOOR C/W CONCEALED

HINGE AND TOUCH LATCH HARDWARE FOR

SEAMLESS APPEARANCE IN WALL.

INSTALL NEW LOCK WITH MASTER KEY SETUP BY

HEAD OFFICE. INSTALL LOCK ON POCKET PANEL

DOOR, TO BE KEYED ALIKE WITH CASH COUNTER

DRAWERS IF POSSIBLE.

EXISTING FIRE HOSE CABINET TO REMAIN

1'-6 1/2"

1

'

-

6

"

4

'

-

7

"

NEW INTERIOR PARTITION,

REFER TO WALL PARTITION SCHEDULE

1'-0"

2'-2

"

NEW GRILLE ENCLOSURE PARTITION.

REFER TO WALL PARTITION SCHEDULE

D101

D102

6

'-

1

1

/

2

"

1

'-

6

"

EXISTING DOOR , FRAME AND HARDWARE TO REMAIN.

DOOR AND FRAME TO RECEIVE NEW PAINT.

REFER TO DWG.2.3

2'-0"

2'-0

"

NEW GRILLE DOOR AND TRACK

ABOVE, TYPICAL.

13'-0"

NEW INTERIOR PARTITION.

REFER TO WALL PARTITION SCHEDULE

G.C. TO PROVIDE GWB, PAINTED, FROM 8'-0" A.F.F.

TO 12'-0" A.F.F., TYPICAL

EXISTING COLUMN TO BE RECLADDED WITH METAL

STUDS AND GWB. REFER TO WALL PARTITION

SCHEDULE FOR WALL TYPE.

2

'-

0

"

2

'

-

5

1

/

2

"

D103

NEW 1'-0" W x 7'-0" H SERVICE DOOR C/W CONCEALED

HINGE AND TOUCH LATCH HARDWARE FLUSHED FOR

SEAMLESS APPEARANCE IN WALL.

WOOD VENEER ON MDF

3

'

-

0

"

3

'

-

0

"

2

'-

0

"

W-1W-1

W-1

W-1

W-1

W-1

W-4

W-5

W-4

W-5

W-5

PROVIDE BLOCKING TO SUPPORT

CABINET HINGES

GC TO SUBMIT ENGINEER SIGNED AND

SEALED SHOP DRAWINGS FOR REVIEW. ALL

RECESSED PINS TO HAVE SPRING CORDED

COVERS.

SLIDING GRILLES - SPEC. BELOW:

INSTALL NEW GRILLE DYNAFLAIR

MODEL: ELEGANCE C/W EGRESS DOOR ON

SEPARATE HINGE EQUIPPED WITH 1"

MORTISE THUMB TURN ACTUATOR ON INSIDE

ONLY.

- DOOR MUST BE ABLE TO LOCK FROM

THE OUTSIDE

- INSTALL TOP & BOTTOM LOCKING PINS

AT BOTH ENDS OF THE GRILLE DOOR

SO THE POCKET DOOR PANEL REMAINS

CLOSED ONCE THE GRILLE DOOR HAS

BEEN PULLED OUT

- INSTALL NEW LOCK WITH MASTER KEY

SET UP BY HEAD OFFICE

- INSTALL LOCK ON POCKET PANEL DOOR

TO BE KEYED ALIKE WITH CASH

COUNTER DRAWERS IF POSSIBLE

GWB BULKHEAD ABOVE

PROVIDE RECESSED CONNECTION BOX

FOR MONITOR ABOVE BANQUETTE

EX-D100

EX-D100

D101

D103

D102

G.C. TO PROVIDE 4'-0" x 8'-0" x 3/4" THK.

FIRE-TREATED PLYWOOD BACKING FOR

I.T. EQUIPMENT AND RACKING

LOCATION OF EXISTING ELECTRICAL PANEL

REFER TO ELECTRICAL FOR DETAILS

5

"

7'-1 1/2"

2'-0

"

1

A3.0

2

A3.0

3

A4.1

SYMBOL WALL TYPE DESCRIPTION

EXISTING DEMISING WALL PARTITION TO REMAIN

· PATCH AND REPAIR AS REQUIRED FOR NEW WALL FINISHES

NEW INTERIOR PARTITION 1 (TO U/S OF NEW CEILING)

· 1/2" TYPE 'X' GYPSUM BOARD BOTH SIDES

· 3 5/8" STEEL STUDS @ 16" O.C.

· TYPE 'S' DRYWALL SCREWS SPACED 7" O.C.

· TAPE, SPACKLE AND SAND, READY TO RECEIVE NEW FINISH.

NEW GRILLE ENCLOSURE / MILLWORK PARTITION

· 3/4" MDF PANEL C/W FINISH WD-1 (BY MILLWORK CONTRACTOR)

· 3/4" PLYWOOD SHEETING

· 3 5/8" STEEL STUDS @16" O.C.

· MDF MILLWORK TO SECURE TO PARTITION AS REQUIRED.

REFER TO DWG. A3.0 FOR MILLWORK DETAILS

NEW FURRED OUT PARTITION (TO 12'-0" A.F.F. / GWB BULKHEAD)

· 1/2" TYPE 'X' GYPSUM BOARD ONE SIDE ONLY

· 3 5/8" STEEL STUDS @ 16" O.C.

· PRE-FINISHED MILLWORK PANELS SUPPLIED BY MILLWORK CONTRACTOR

MOUNTED ON EXTERIOR SIDE ONLY

WALL PARTITION SCHEDULE

1. IT IS THE CONTRACTORS RESPONSIBILITY TO VISIT THE SITE AND EXAMINE ALL ASPECTS

THOROUGHLY PRIOR TO SUBMITTING A BID, AND TO UNDERSTAND ALL ASPECTS OF THE EXISTING

SITE AND THE SCOPE OF WORK REQUIRED TO COMPLETE THE SPACE, READY TO OPEN THE

DOORS FOR BUSINESS. ALSO TO EXAMINE THE EXISTING CONSTRUCTION TO DETERMINE HOW TO

BEST PROCEED WITH DEMOLITION AS WELL AS THE TYPES OF MATERIALS BEING DEMOLISHED.

2. PATCH AND REPAIR AS NECESSARY ALL WALLS, CEILING, FLOORING ETC. TO REMAIN READY TO

RECEIVE FINAL NEW FINISHES. MAINTAIN ALL EXISTING FIRE RATINGS AND SEPARATIONS. PATCH,

REPAIR & MAKE GOOD AS REQUIRED TO ENSURE THAT FIRE RESISTANCE RATINGS ARE NOT

COMPROMISED.

3. CONTRACTOR TO PROVIDE BLOCKING IN WALLS AS NECESSARY TO SUPPORT ALL NEW FINISHES

AND MILLWORK ITEMS. REFER TO ELEVATIONS AND ALL OTHER DRAWINGS TO ESTABLISH ALL

LOCATIONS. SUBSTANTIAL COORDINATION IS REQUIRED TO FOLLOW THE DESIGN INTENT IN

CONTEXT WITH THE EXISTING FEATURES, BASED ALSO ON NOT HAVING EXISTING AS-BUILT

DRAWINGS TO REFER TO WITH RESPECT TO ASPECTS SUCH AS ELECTRICAL AND STRUCTURAL

ASPECTS ABOVE, BELOW, AND WITHIN THE SPACES REQUIRING RENOVATION.

4. FIT TEMPORARY HOARDING TO STOREFRONT, AS PER MALL STANDARDS AND POLICIES FOR

PUBLIC SAFETY AND PRIVACY REGULATIONS

5. NOISY WORK TO BE PERFORMED IN ACCORDANCE WITH THE MALL'S HOURS SET FORTH IN RULES

& REGULATIONS.

6. ALL MATERIALS TO MEET FLAME SPREAD RATINGS REQUIREMENTS OF AUTHORITIES HAVING

JURISDICTION.

7. ALL ROOF-MOUNTED EQUIPMENT TO BE INSTALLED ON PLATFORMS TO LANDLORD'S DETAIL AND

LOCATION AT THE TENANT'S EXPENSE.

8. NEITHER THE TENANT NOR THE TENANT'S CONTRACTOR'S ARE PERMITTED TO CUT ROOF

OPENINGS. SUCH WORK SHALL BE INITIATED & EXECUTED BY THE LANDLORD AT THE TENANT'S

EXPENSE.

9. CONTRACTOR TO ENSURE THAT ALL FIXTURES, PARTITIONS AND INTERIOR ELEMENTS ARE

COMPLIANT WITH CITY'S BUILDING CODE SEISMIC RESTRAINT REQUIREMENTS

10. DURING THE TENDER PERIOD, IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND ALL

SUBTRADES TO VERIFY ALL DIMENSIONS AND CONDITIONS AS SHOWN ON THESE DRAWINGS WITH

ACTUAL SITE CONDITIONS. ANY DISCREPANCIES TO BE REPORTED TO THE CONSULTANTS, PRIOR

TO COMMENCEMENT OF CONSTRUCTION AND/OR INSTALLATION. ANY EXTRA WHICH A VISIT ON

SITE WOULD HAVE MADE APPARENT, WILL NOT BE ALLOWED.

11. ALL ELECTRICAL MATERIAL AND HARDWARE AS SPECIFIED ON DRAWINGS ARE TO BE SUPPLIED

AND INSTALLED BY CONTRACTOR.

12. PATCH AND REPAIR CONCRETE SLAB THROUGHOUT AS NECESSARY, READY TO RECEIVE NEW

FINISHES. CONTRACTOR TO ENSURE ALL EXISTING WALLS AND FLOORS ARE PROPERLY PREPARED

FOR INSTALLATION OF SPECIFIED MATERIALS. PATCH & REPAIR AS NECESSARY, READ TO RECEIVE

NEW FINISH (CARPET, PAINT, LAMINATE, RESILIENT FLOORING, ETC.)

GENERAL CONSTRUCTION NOTES

NEW INTERIOR PARTITION 2 (TO U/S OF NEW CEILING)

· 1/2" TYPE 'X' GYPSUM BOARD BOTH SIDES

· 6" STEEL STUDS @ 16" O.C.

· TYPE 'S' DRYWALL SCREWS SPACED 7" O.C.

· TAPE, SPACKLE AND SAND, READY TO RECEIVE NEW FINISH.

W-1

W-2

W-3

W-4

W-5

CONSTRUCTION PLAN

A2.1

DG

AS SHOWN

UN

IT

7

58

, 3

00

B

oro

ug

h D

rive

SC

AR

BO

RO

UG

H

TO

WN

C

EN

TR

E

Sca

rb

oro

ug

h, O

nta

rio

DESCRIPTION

DRAWING TITLE

PROJECT

SHEET NO.

SCALE:

DATE:

CHECKED BY:

DRAWN BY:

PROJECT NO.:

BY

JOHN E. GUSTAVSON ARCHITECT INC.

USE OR REPRODUCTION PROHIBITED

WITHOUT PRIOR WRITTEN PERMISSION.

THE GENERAL CONTRACTOR SHALL

REVIEW THE DOCUMENTS FOR

CONFORMANCE OF CODES AND

BYLAWS AND SHALL ADVISE THE

ARCHITECT OF ANY DISCREPANCIES HE

MAY NOTE. THE GENERAL CONTRACTOR

SHALL CHECK AND VERIFY ALL

DIMENSIONS AND REPORT ALL ERRORS

AND OMISSIONS TO THE DESIGNER, DO

REVISIONNO DATE

NOT SCALE THE DRAWINGS.

ALL RIGHTS RESERVED. PROPERTY OF

BYISSUED FORNO DATE

16224

DC

Unit 758, 300 Borough Drive, Scarborough, Ontario

SCARBOROUGH

TOWN CENTRE

ISSUED FOR TENDER

DGISSUED FOR COORDINATION101/16/17

January 27, 2017

JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,

VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203

www.gwa.ca

BWISSUED FOR LANDLORD REVIEW201/20/17

BWISSUED FOR BUILDING PERMIT301/27/17

BWISSUED FOR TENDER 404/03/17

SCALE:

1

CONSTRUCTION PLAN

3/8" = 1'-0"

NORTH

AutoCAD SHX Text
FHC

A

FE

2'-1

1"

4'-0

"

2"

4'-0

"9

"4

'-0

"4

'-0

"4

'-0

"4

'-0

"1

'-8

"2

'-2

"8

"3

'-1

0"

4"

6'-0

"6

"5

'-1

0"

5'-10 1/2"

2'-0

"4

'-1

0"

4'-8" 3'-4" 4'-8"

3'-4"

4'-0

"4

'-0

"

7

"

4

'

-

0

"

4

"

6

'

-

0

"

8

1

/

2

"

4

'

-

7

"

S-6

F-7

F-5

S-6

FUR-1

M-4

M-7

M-3

M-2

F-3

F-1

D-1

2'-0

"

12'-4"

8'-0

"4

8'-1

0"

23

'-9

"

1

7

'

-

3

1

/

2

"

NOTE:

NO VISIBLE WIRE, CONDUIT OR FASTENERS

PERMITTED.

2'-0"

2

A4.0

2

A4.1

1

A4.1

1

A4.0

3

A

3

.

0

WOOD SHELVING C/W WALL-MOUNTED METAL

TWIN SLOT UPRIGHTS AND BRACKETS. 96" HIGH x

14" DEEP WITH 5/8" MDF BULLNOSE SHELVES.

PROVIDE 5 SHELVES PER SHELVING UNIT AND

PLYWOOD BACKING.

S-4

7'-1 1/2"

M-6

4'-0

"

F-6

2"

4'-0

"8

"4

'-0

"

M-8

D-2

1

'

-

1

"

M-8

D-2

3'-4"

FUR-1

FUR-2

FUR-2

FUR-1

FUR-1

FUR-2

FUR-2

S-6

S-6

S-6

4'-1

1"

5'-9

"1

0'-0

"8

'-0

"

4'-0"

S-6

S-6

S-6

F-4

F-2

5'-1" 2'-6"

3

'

-

0

"

3

'

-

0

"

2

'

-

6

"

4

'

-

0

"

2

'-

6

"

S-2

M-1

5

'

-

3

1

/

2

"

5

'-

5

1

/

2

"

3

'

-

3

"

3

'

-

3

"

S-3

11

"

D-3

S-4

S-3

1

A3.0

2

A3.0

3

A4.1

NEW MILLWORK SCHEDULE

NO. DESCRIPTION:

CARRIER WALL DETAILM-1

QUANTITY:

1

SM PHONE DISPLAYM-22

LG PHONE DISPLAYM-31

POS CASH FIXTUREM-41

ACCESSORIES DISPLAYM-55

BANQUETTEM-61

OTTOMANM-71

TV FIXTUREM-8

2

NEW FURNITURE SCHEDULE

NO. DESCRIPTION:

COUNTER HEIGHT STOOL

TBD

FUR-1

QUANTITY:

4

TABLE HEIGHT STOOL

TBD

4

SCREEN AT ENTRY

PORTRAIT BY CLIENT

D-11

SCREEN ON

LANDSCAPE BY CLIENT

D-22

M-8

NEW DIGITAL SCHEDULE

NO. DESCRIPTION:

CARRIER LOGOS COLLAGE

[REFER TO FA FOR MORE INFO]

S-1

QUANTITY:

1 GROUPING

VINYL ON GLASS

S-2

1

VINYL DECALS ON GLASS

[REFER TO FA FOR MORE INFO]

S-3

1 GROUPING

ACCESSORIES SIGNAGE BACKLIT GRAPHIC

S-4

5

BACK WALL BACKLIT GRAPHIC

S-5

1

FUR-2

EXISTING FIXTURES SCHEDULE

NO. DESCRIPTION:

SAMSUNGF-1

QUANTITY:

1

APPLEF-2

LGF-3

1

GOOGLEF-4

1

CHATRF-5

ROGERSF-6

1

BELLF-7

1

1

1

S-6

STOREFRONT SIGN 1

REFER TO SEPARATE MILLWORK PACKAGE FOR MORE INFORMATION.

1. REFER TO MILLWORK DRAWING PACKAGE, UNDER SEPARATE COVER, IN CONJUNCTION WITH THIS PACKAGE.

2. ALL FIXTURES ARE TO BE PROVIDED AND INSTALLED BY THE MILLWORK CONTRACTOR UNLESS OTHERWISE

NOTED.

3. ALL FURNITURE ITEMS ARE TO BE SUPPLIED BY CLIENT UNLESS OTHERWISE NOTED.

4. ALL FURNITURE ITEMS ARE TO BE ASSEMBLED AND SET IN PLACE BY THE GENERAL CONTRACTOR.

5. ALL EQUIPMENT AND TV TO BE SUPPLIED BY OWNER AND INSTALLED BY GC.

GENERAL NOTES

NOTES:

NOTES:

NOTES:

NOTES:

SUPPLIED BY OTHERS

C/W POWER AND DATA

SUPPLIED BY OTHERS

C/W POWER AND DATA

SUPPLIED BY OTHERS

C/W POWER AND DATA

SUPPLIED BY OTHERS

C/W POWER AND DATA

SUPPLIED BY OTHERS

SUPPLIED BY OTHERS

SUPPLIED BY OTHERS

MILLWORK CONTRACTOR

MILLWORK CONTRACTOR

MILLWORK CONTRACTOR

MILLWORK CONTRACTOR

MILLWORK CONTRACTOR. NO PAC POLE,

POWER TO FED FROM BASE OF MILLWORK

MILLWORK CONTRACTOR. NO PAC POLE,

POWER TO FED FROM BASE OF MILLWORK

MILLWORK CONTRACTOR. NO PAC POLE,

POWER TO FED FROM BASE OF MILLWORK

MILLWORK CONTRACTOR

SUPPLIED BY OTHERS

SUPPLIED BY OTHERS

SAMSUNG SCREEN AT ENTRY

PORTRAIT BY CLIENT

D-31

SUPPLIED BY OTHERS

C/W POWER AND DATA

FIXTURE PLAN

A2.2

DG

AS SHOWN

UN

IT

7

58

, 3

00

B

oro

ug

h D

rive

SC

AR

BO

RO

UG

H

TO

WN

C

EN

TR

E

Sca

rb

oro

ug

h, O

nta

rio

DESCRIPTION

DRAWING TITLE

PROJECT

SHEET NO.

SCALE:

DATE:

CHECKED BY:

DRAWN BY:

PROJECT NO.:

BY

JOHN E. GUSTAVSON ARCHITECT INC.

USE OR REPRODUCTION PROHIBITED

WITHOUT PRIOR WRITTEN PERMISSION.

THE GENERAL CONTRACTOR SHALL

REVIEW THE DOCUMENTS FOR

CONFORMANCE OF CODES AND

BYLAWS AND SHALL ADVISE THE

ARCHITECT OF ANY DISCREPANCIES HE

MAY NOTE. THE GENERAL CONTRACTOR

SHALL CHECK AND VERIFY ALL

DIMENSIONS AND REPORT ALL ERRORS

AND OMISSIONS TO THE DESIGNER, DO

REVISIONNO DATE

NOT SCALE THE DRAWINGS.

ALL RIGHTS RESERVED. PROPERTY OF

BYISSUED FORNO DATE

16224

DC

Unit 758, 300 Borough Drive, Scarborough, Ontario

SCARBOROUGH

TOWN CENTRE

ISSUED FOR TENDER

DGISSUED FOR COORDINATION101/16/17

January 27, 2017

JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,

VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203

www.gwa.ca

BWISSUED FOR LANDLORD REVIEW201/20/17

BWISSUED FOR BUILDING PERMIT301/27/17

BWISSUED FOR TENDER 404/03/17

SCALE:

1

FIXTURE PLAN

3/8" = 1'-0"

NORTH

AutoCAD SHX Text
FHC
AutoCAD SHX Text
FHC

7'-6"

7'-5

1

/2

"

2'-0

"3

'-6

"3

'-6

"

4'-6

1

/2

"4

'-4

"3

'-1

1 1

/2

"2

'-7

"

ALL EXISTING WALL OUTLETS

TO REMAIN WHERE POSSIBLE.

RELOCATE AS NEEDED TO

SUIT NEW LAYOUT.

SCAN SLAB PRIOR TRENCHING

OR CORING. NOTIFY MALL

OPERATIONS PRIOR TO WORK.

POWER & DATA RECEPTACLES

FOR EXPERIENCE TABLE F1A.

MOUNT TO UNDERSIDE OF TABLE.

SUPPLY POWER & DATA FOR

EXPERIENCE TABLE THROUGH

CONDUIT, TRENCH AND FLOOR BOX.

CONDUITS TO CEILING SPACE, TYP.

REFER TO ELECTRICAL

EXISTING ELECTRICAL PANELS TO

REMAIN. REFER TO ELECTRICAL

EXISTING TRANSFORMER AT ABOVE

1

'

-

6

"

1'-6 1/2"

1

'

-

6

"

4

'

-

7

"

1'-0"

2'-2

"

3'-6

"4

'-2

"4

'-2

"5

'-6

"3

'-8

"4

'-9

"

POWER, PHONE & DATA

RECEPTACLES FOR CASH TABLE F1.

MOUNT TO UNDERSIDE OF TABLE.

17

'-0

"

POWER, PHONE & DATA

RECEPTACLES FOR PHONE TABLE

F1N. MOUNT TO UNDERSIDE OF

TABLE.

6'-9

"

1

6

'

-

7

"

SUPPLY POWER & DATA

FOR CASH TABLE

THROUGH CONDUIT,

TRENCH AND FLOOR BOX.

7'-6"

2'-5

"1

6'-7

"1

0'-1

"

6'-0"

POWER CONNECTION TO TIME

CLOCK FOR SIGNAGE ABOVE

6

'-

1

1

/

2

"

1

'-

6

"

2'-0"

2'-0

"

13'-0"

2

'-

0

"

2

'

-

5

1

/

2

"

3

'

-

0

"

3

'

-

0

"

2

'-

0

"

4'-2

"

5'-8

"

4

'

-

9

1

/

2

"

4

'

-

2

1

/

2

"

6

'

-

8

1

/

2

"

6

'

-

6

1

/

2

"

6

'-

7

"

EXISTINGTEL/COMMUNICATION PANEL

TO REMAIN

2'-8

1

/2

"

SUPPLY POWER & DATA FOR CASH

TABLE THROUGH CONDUIT, TRENCH

AND FLOOR BOX.

EXISITNG ELECTRICAL

DEVICES IN STORE ROOM TO

REMAIN, UNLESS NOTED

OTHERWISE.

4'-0

1

/2

"

1'-9"

5

"

1. ALL CONSTRUCTION AND ELECTRICAL OUTLET WIRING TO COMPLY WITH

LOCAL BUILDING CODES AND OTHER APPLICABLE REGULATIONS TO

REDUCE RISK OF FIRE AND ELECTRICAL HAZARDS.

2. FOR FINAL ELECTRICAL CONNECTIONS REFER TO ELECTRICAL DRAWINGS

AND SPECIFICATIONS.

3. ALL ELECTRICAL MATERIAL AND HARDWARE AS SPECIFIED ON DRAWINGS

ARE TO BE SUPPLIED AND INSTALLED BY CONTRACTOR.

4. FOR DIMENSIONAL PURPOSES ONLY, COORDINATE WITH ELECTRICAL

ENGINEERING DRAWINGS.

5. ALL OUTLETS TO BE BLACK WITH STAINLESS STEEL COVER PLATES UNLESS

LOCATED WITHIN MILLWORK.

6. CONTRACTOR TO VERIFY EXISTING ELECTRICAL OUTLETS WITHIN SPACE

AND RELOCATE/ ADD NEW OUTLETS AS SPECIFIED ON DRAWING. REWIRE

EXISTING ELECTRICAL OUTLETS TO NEW POWER SOURCE AS REQUIRED.

7. ALL EXISTING AND NEW SWITCH PLATES TO BE REPLACED WITH STAINLESS

STEEL PLATES IN RETAIL SPACE. CONTRACTOR TO VERIFY QUANTITY ON

SITE.

8. STOREFRONT SIGNAGE TO BE ELECTRIFIED/ HARD-WIRED TO BE

CONTROLLED BY 24 HOUR TIMER AND OPERATED DURING THE HOURS

SPECIFIED BY LANDLORD

9. REFER TO ENGINEERS DRAWINGS FOR EMERGENCY LIGHTS, EXIT SIGNS

AND REQUIRED FIRE EXTINGUISHER CABINETS.

10. GENERAL CONTRACTOR SHALL COORDINATE GANG BOX AND JUNCTION

BOX LOCATIONS AND REQUIREMENTS WITH FIXTURE/MILLWORK VENDOR

PRIOR TO INSTALLATION.

11. GENERAL CONTRACTOR TO COORDINATE ALL HOLES AND GROMMET

LOCATIONS IN FIXTURES/MILLWORK WITH CLIENT APPOINTED

REPRESENTATIVE/PROJECT MANAGER.

12. PAINT ALL EXPOSED CONDUIT TO MATCH ADJACENT FINISH.

13. IN EXISTING SPACES, IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT

THE SITE AND VERIFY ALL EXISTING ELECTRICAL AND DATA LINES.

14. ALL REDUNDANT EXISTING WIRING TO BE REMOVED AND DISCONNECTED

AT SOURCE (I.E. ELECTRICAL PANEL OR JUNCTION BOX).

15. EXISTING OUTLETS TO BE REUSED IF FALL IN CLOSE PROXIMITY TO NEW

OUTLETS SHOWN ON PLAN - REWIRE TO NEW POWER SOURCE AS

REQUIRED.

16. ALL OUTLETS ON COLUMNS MUST BE FLUSH WITH FINAL FINISH - COLUMNS

MUST BE FURRED OUT TO HOUSE J-BOXES/CONDUIT AS REQUIRED.

17. PROVIDE SEISMIC RESTRAINT TO ALL EQUIPMENT AND ALL FIXTURES AS

REQUIRED.

18. G.C. TO CONFIRM THAT LANDLORD WILL SUPPLY INCOMING ELECTRICAL

SERVICE -600V, 3 PHASE, 3 WIRE ALTERNATING CURRENT, FUSED

DISCONNECT SWITCH, AND PANEL. CONTRACTOR TO PROVIDE SPLITTER

FOR HVAC EMERGENCY LOCAL REGULATIONS.

19. ALL ELECTRICAL P/V/D MOUNTED AT 12" A.F.F. UNLESS OTHERWISE NOTED.

MECHANICAL NOTESELECTRICAL LEGEND

SYMBOL DESCRIPTION

FOURPLEX ELECTRICAL RECEPTACLE

· WALL-MOUNTED OUTLET

ELECTRICAL OUTLET MOUNTED IN MILLWORK

· MOUNTING HEIGHT TO BE DETERMINED BY MILLWORK CONTRACTOR

VOICE/DATA OUTLET FOR FAX/PRINTER

GENERAL NOTES

EXISTING ELECTRICAL RECEPTACLE TO REMAIN

· CONTRACTOR TO ENSURE IN GOOD WORKING ORDER.

1/2" CONDUIT FOR COMMUNICATION WIRING

· CONDUIT IN WALL

· TO CONTAIN PULL STRING TO BACK ROOM

DUPLEX ELECTRICAL RECEPTACLE

· WALL-MOUNTED OUTLET

· REFER TO ELECTRICAL ENGINEER'S DRAWINGS AND SPECIFICATIONS.

· ALL OUTLETS TO BE BLACK WITH STAINLESS STEEL COVER PLATES

UNLESS LOCATED WITHIN MILLWORK

· ALL OTHER EXISTING OUTLETS TO BE REPLACED OR REMOVED AS

REQUIRED

CEILING MTD. POWER DATA AND COMMUNICATION OUTLETS

DATA OUTLET

TELEPHONE OUTLET

SINGLE ELECTRICAL WALL OUTLET

NETWORK PRINTER CABLE

· TO BE RUN BACK TO BACK R00M

PANEL NOTES

CAT 5E GRADE DATA CABLING ONLY FOR BOTH DATA AND VOICE. AS FOLLOWS:

· ONE (1) CABLE PER POS TERMINAL STATION

· TWO (2) CABLES FOR THE FACIMILIE/PRINTER

· ONE (1) CABLE FOR EACH TRANSELECT MACHINE

· ONE (1) CABLE FOR EACH PHYSICAL TELEPHONE.

· COMFIRM (2) TELEPHONES PER STORE, AND THEIR LOCATION WITH

TENANT

· ALL CABLES ARE TO BE PULLED BACK TO THE COMMUNICATIONS PANEL

LOCATION

PANEL, CIRCUIT BREAKER INFORMATION:

· ONE (1) DEDICATED CIRCUIT BREAKER/ OUTLET FOR TENANT'S

COMMUNICATION PANEL

· ONE (1) DEDICATED CIRCUIT BREAKER/ OUTLET FOR EACH POS TERMINAL,

CONSISTING OF 1 COMPUTER, MONITER, AND THERMAL RECEIPT PRINTER

· TELEPHONES AND TRANSELECT MACHINE CAN SHARE THE CIRCUIT WITH

THE POS.

· ONE (1) DEDICATED CIRCUIT BREAKER/ OUTLET FOR THE FACSIMILE/

PRINTER TERMINAL STATION.

PANEL NOTE:

· COMMUNICATION PANEL TO BE INSTALLED IN CLOSE PROXIMITY TO

ELECTRICAL PANEL, TERMINAL STATION.

CAT-5 DATA DROP

TRENCH, REFER TO DETAIL 2/A2.4

FLOOR BOX, REFER TO ELECTRICAL

* G.C. TO COORDINATE ALL MECHANICAL AND ELECTRICAL REQUIREMENTS

WITH SNC LAVALIN.

* G.C. TO COORDINATE ALL MECHANICAL AND ELECTRICAL REQUIREMENTS

WITH SNC LAVALIN.

EXISTING

TOPPING SLAB

EXISTING

STRUCTURAL SLAB

1" DIAMETER CONDUIT. REFER TO

POWER & DATA PLAN FOR NUMBER

OF CONDUIT REQUIRED.

2" 2" 2"

8"

1"1"

POWER & DATA

PLAN

A2.4

DG

AS SHOWN

SCALE:

1

POWER & DATA PLAN

3/8" = 1'-0"

UN

IT

7

58

, 3

00

B

oro

ug

h D

rive

SC

AR

BO

RO

UG

H

TO

WN

C

EN

TR

E

Sca

rb

oro

ug

h, O

nta

rio

DESCRIPTION

DRAWING TITLE

PROJECT

SHEET NO.

SCALE:

DATE:

CHECKED BY:

DRAWN BY:

PROJECT NO.:

BY

JOHN E. GUSTAVSON ARCHITECT INC.

USE OR REPRODUCTION PROHIBITED

WITHOUT PRIOR WRITTEN PERMISSION.

THE GENERAL CONTRACTOR SHALL

REVIEW THE DOCUMENTS FOR

CONFORMANCE OF CODES AND

BYLAWS AND SHALL ADVISE THE

ARCHITECT OF ANY DISCREPANCIES HE

MAY NOTE. THE GENERAL CONTRACTOR

SHALL CHECK AND VERIFY ALL

DIMENSIONS AND REPORT ALL ERRORS

AND OMISSIONS TO THE DESIGNER, DO

REVISIONNO DATE

NOT SCALE THE DRAWINGS.

ALL RIGHTS RESERVED. PROPERTY OF

BYISSUED FORNO DATE

16224

DC

Unit 758, 300 Borough Drive, Scarborough, Ontario

SCARBOROUGH

TOWN CENTRE

ISSUED FOR TENDER

DGISSUED FOR COORDINATION101/16/17

January 27, 2017

JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,

VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203

www.gwa.ca

BWISSUED FOR LANDLORD REVIEW201/20/17

BWISSUED FOR BUILDING PERMIT301/27/17

BWISSUED FOR TENDER 404/03/17

SCALE:

2

TRENCH DETAIL

3" = 1'-0"

NORTH

AutoCAD SHX Text
FHC
AutoCAD SHX Text
B
AutoCAD SHX Text
E
AutoCAD SHX Text
NP
AutoCAD SHX Text
CAT-5

4" S.S. GLAZING CHANNEL

1/2" TEMPERED GLASS, PROVIDE

ENGINEER SIGNED AND SEALED SHOP

DRAWINGS

6" S.S. GLAZING CHANNEL

GWB BULKHEAD AT 11'-0" AFF,

PAINTED PT-2

4" HIGH MDF LIP,

PAINTED TO MATCH PT-2

1/2" ALUMINUM REVEAL

NEW STOREFRONT MDF

BULKHEAD TO RECEIVE NEW

FINISH WD-1

MAKE GOOD CONNECTION WITH

LANDLORD BULKHEAD, SIGNED

AND SEALED ENGINEER SHOP

DRAWING FOR GLAZING AND

SUPPORT

1/2" ALUMINUM REVEAL

3'-2"

4"

3'-6"

10'-6" A

FF

FINISHED FLOOR

G.C. TO VERIFY DIMENSIONS OF LCD

MONITORS PRIOR TO CONSTRUCTING

OPENING; ADJUST OPENING TO

ENSURE 1/2" GAP AROUND LCD

MONITORS - ALL SIDES

G.C. TO COORDINATE FINAL

EQUIPMENT & RECESS SIZE W/

CLIENT

LC

D N

IC

HE

, D

IM

T

BD

LCD MONITOR TO BE RECESSED INTO

PARTITION. CONTRACTOR TO PROVIDE

MOUNTING HARDWARE AS REQUIRED.

CUT HOLES IN BACK FOR WIRE ACCESS

AND VENTIN

CONTRACTOR TO PROVIDE 1/2" PLYWOOD

BLOCKING BEHIND DRYWALL TO SECURE

LCD. DRYWALL TO BE PAINTED BLACK

ALL SIDES OF RECESS TO BE PAINTED

BLACK

BLACK PAINT SPEC: BENJAMIN MOORE

'UNIVERSAL BLACK' 2118-10

DIM

EN

SIO

N T

BD

RETAIL AREA SIDE

PROVIDE SLOTS FOR AIR CIRCULATION

BEHIND LCD, TOP & BOTTOM TYP.

9 3/4"

PROVIDE WOOD BLOCKING

FINISHED FLOOR

NEW 6" H BREAK METAL BASEBOARD

WITH BRUSHED STAINLESS STEEL

LOOK

5"

MDF MILLWORK FINISH WD-1

MDF MILLWORK FINISH WD-1

3 1/2"

BULKHEAD

SUPPORT

BY CONTRACTOR

SUSPENDED BULKHEAD,

5/8" GWB OVER METAL

STUD FRAMING @ 16" O.C.

BY GENERAL CONTRACTOR

C/W FINISH ON

ALL EXTERIOR SIDES

U/S OF EXISTING CEILING

10

'-6

" A

FF

T

O U

/S

OF

N

EW

C

EN

TE

R B

UL

KH

EA

D

3 1/2"

VA

RIE

S

TOP OF FINISHED

FLOOR

12" MIN.

PT-1

G.C. TO PROVIDE

ENGINEER SIGNED AND

SEALED SHOP DRAWINGS

C/W SCHEDULES FOR ALL

STRUCTRUAL SUPPORTS

OF BULKHEAD

6'-0"

12" MIN.

2'-8" 8" 3'-10"

G.C. TO COORDINATE

LOCATION OF HVAC SYSTEM

WITHIN BULKHEAD

9'-6

" A

FF

(N

.T

.S

.) T

O U

/S

OF

N

EW

P

EN

DA

NT

F

IX

TU

RE

1

2'-0

" A

FF

T

O T

/O

E

XIS

TIN

G G

WB

W

AL

L

1'-1

"

1

0'-6

" A

FF

T

O U

/S

O

F B

UL

KH

EA

D8

"

5/8

"

6"

8"

5/8" THK. GWB LIGHT COVE

VALANCE C/W CORNER

BEAD, PAINTED

FINISH

ON ALL EXTERIOR SIDES.

U/S OF VALANCE TO ALIGN

WITH U/S OF CENTER

BULKHEAD @ 10'-6" AFF.

PT-1

ALL CEILING METAL

STUD FRAMING

SECURED TO CEILING

STRUCTURE ABOVE,

PAINTED FLAT BLACK

U/S OF EXISTING

CEILING

2'-0"

SUSPENDED BULKHEAD,

5/8" GWB OVER METAL STUD

FRAMING @ 16" O.C.

BY GENERAL CONTRACTOR

C/W FINISH ON ALL

EXTERIOR SIDES

PT-1

6"

TOP OF FINISHED

FLOOR

BULKHEAD

SUPPORT

BY CONTRACTOR

EXISTING GWB, PAINTED

VA

RIE

S

3/4" THK. CONTINUOUS

PLYWOOD BACKING

BEHIND GWB

12" MIN.

3"

RE

CE

SS

LINE OF FINISHED

CEILING

EQ.EQ.

8"

PROVIDE WOOD

BLOCKING WITHIN

DRYWALL CEILING

FOR TRACK

MOUNTING

G.C. TO VERIFY DIMENSIONS OF

SAMSUNG SCREEN PRIOR TO

CONSTRUCTING OPENING; ADJUST

OPENING TO ENSURE 1/2" GAP

AROUND SCREEN - ALL SIDES

G.C. TO COORDINATE FINAL

EQUIPMENT & RECESS SIZE W/

CLIENT

3'-1" LC

D N

IC

HE

LCD MONITOR TO BE RECESSED INTO

PARTITION AND FLUSHED WITH MILLWORK

FINISH. CONTRACTOR TO PROVIDE

MOUNTING HARDWARE AS REQUIRED.

CUT HOLES IN BACK FOR WIRE ACCESS

AND VENTIN

CONTRACTOR TO PROVIDE 1/2" PLYWOOD

BLOCKING BEHIND DRYWALL TO SECURE

LCD. DRYWALL TO BE PAINTED BLACK

ALL SIDES OF RECESS TO BE PAINTED

BLACK

BLACK PAINT SPEC: BENJAMIN MOORE

'UNIVERSAL BLACK' 2118-10

4'-0"

MALL AREA SIDE

PROVIDE SLOTS FOR AIR CIRCULATION

BEHIND LCD, TOP & BOTTOM TYP.

7 7/8"

PROVIDE WOOD BLOCKING

FINISHED FLOOR

NEW 6" H BREAK METAL BASEBOARD

WITH BRUSHED STAINLESS STEEL

LOOK

3 1/8"

1/2"

SAMSUNG SCREEN TO BE SECURELY

FASTENED TO PLYWOOD BACKING WITH

Z-CLIPS AND CARRIAGE BOLTS FOR THIEF

PREVENTION

3'-0"

1/2"

ALIGN

ALIGN

MDF MILLWORK FINISH WD-1

MDF MILLWORK FINISH WD-1

WALL SECTIONS

A3.0

DG

AS SHOWN

UN

IT

7

58

, 3

00

B

oro

ug

h D

rive

SC

AR

BO

RO

UG

H

TO

WN

C

EN

TR

E

Sca

rb

oro

ug

h, O

nta

rio

DESCRIPTION

DRAWING TITLE

PROJECT

SHEET NO.

SCALE:

DATE:

CHECKED BY:

DRAWN BY:

PROJECT NO.:

BY

JOHN E. GUSTAVSON ARCHITECT INC.

USE OR REPRODUCTION PROHIBITED

WITHOUT PRIOR WRITTEN PERMISSION.

THE GENERAL CONTRACTOR SHALL

REVIEW THE DOCUMENTS FOR

CONFORMANCE OF CODES AND

BYLAWS AND SHALL ADVISE THE

ARCHITECT OF ANY DISCREPANCIES HE

MAY NOTE. THE GENERAL CONTRACTOR

SHALL CHECK AND VERIFY ALL

DIMENSIONS AND REPORT ALL ERRORS

AND OMISSIONS TO THE DESIGNER, DO

REVISIONNO DATE

NOT SCALE THE DRAWINGS.

ALL RIGHTS RESERVED. PROPERTY OF

BYISSUED FORNO DATE

16224

DC

Unit 758, 300 Borough Drive, Scarborough, Ontario

SCARBOROUGH

TOWN CENTRE

ISSUED FOR TENDER

DGISSUED FOR COORDINATION101/16/17

January 27, 2017

JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,

VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203

www.gwa.ca

BWISSUED FOR LANDLORD REVIEW201/20/17

BWISSUED FOR BUILDING PERMIT301/27/17

BWISSUED FOR TENDER 404/03/17

SCALE:

2

STOREFRONT GLAZING SECTION

3" = 1'-0" SCALE:

3

GRILLE ENCLOSURE SECTION

3" = 1'-0"

SCALE:

4

CENTRE BULKHEAD SECTION

1" = 1'-0"

SCALE:

6

COVE LIGHT/BULKHEAD SECTION

1" = 1'-0"

SCALE:

5

RETAIL CEILING TROUGH DETAIL

3" = 1'-0"

SCALE:

1

STOREFRONT COLUMN SECTION

3" = 1'-0"

AutoCAD SHX Text
G
AutoCAD SHX Text
PT-1
AutoCAD SHX Text
G

10

'-6

" T

O U

/S

O

F

PR

OP

OS

ED

C

EIL

IN

G

14

'-0

" T

O U

/S

O

F

MA

LL

B

UL

KH

EA

D

3'-2

"

16

'-0

"

TO

U

/S

O

F M

AL

L C

EIL

IN

G

wireless

GRILLE

ENCLOSURE

6'-3" STOREFRONT OPENING

5'-11

1

2

" STOREFRONT OPENING

EXIST. STAINLESS STEEL FINISH /FHC

NEW STOREFRONT BULKHEAD TO

RECEIVE NEW FINISH WD-1

EXISTING ILLUMINATED HALO-LIT

SIGNAGE TO REPLACE WITH NEW

EXISTING STAINLESS STEEL FINISH

TO REMAIN

EXISTING FIRE HOSE CABINET TO

REMAIN

EXISTING STAINLESS STEEL BASE

TO REMAIN

EXISTING DEMISING WALL TO BE RECLADDED,

PL-1

1/2" U-CHANNEL ALUMINUM REVEAL BETWEEN

NEW STOREFRONT FINISH AND EXISTING

BULKHEAD

NEW GRILLE ENCLOSURE C/W

FINISH WD-1

1'-6

"

6'-4

1

2

"

NIC

2'-0"

EXISTING COLUMN TO BE RECLADDED

W/ METAL STUDS & MDF PANELS, WD-1

REFER TO MILLWORK DRAWINGS

FOR FINISHES OF ALL FIXTURE (TYPICAL)

4'-5

1

2

"

WD-1

NEW STOREFRONT GLAZING WITH VINYL STICKER

APPLIED AT THE TOP. OPAGUE PINK TO MATCH PT-2

TO RUN CLEAR OVER A 2'-0" LENGTH

G.C. TO SUPPLY AND INSTALL NEW

6" HIGH BREAKFORM S.S. BASE, MT-1

TO GRILLE ENCLOSURE. (TYP)

GRILLE

ENCLOSURE

G.C. TO SUPPLY AND INSTALL NEW 6" HIGH

BREAKFORM S.S. BASE, MT-1 TO GRILLE

ENCLOSURE AND DEMISING WALL. (TYP)

WD-1

NEW GRILLE ENCLOSURE AND CONCEALED

POCKET DOOR, FINISH WD-1. DOOR TO BE C/W

WITH NO VISIBLE HARDWARE AND TOUCH

LATCH

DEMISING

WALL

G.C. TO PROVIDE 1/8" REVEAL WHERE

INDICATED, TYP., PAINTED BLACK

SEAM BETWEEN POCKET DOOR AND FINISH TO

BE MINIMAL, MAX. 1/4" WIDTH

WHITE FROSTED VINYL DECALS APPLIED TO

THE LEGTH OF GLASS, REFER TO FA FOR MROE

INFORMATION.

4'-0

"

G.C. TO PROVIDE 1/8" REVEAL WHERE

INDICATED, TYP., PAINTED BLACKWD-1

NEW GWB STOREFRONT BULKHEAD

SOFFIT TO RECEIVE NEW PAINT PT-2

SEAM BETWEN POCKET DOOR AND

FINISH TO BE MINIMAL, MAX. 1/4"

WIDTH

IMPROVEMENTS & SIGN NOT TO BE

SUPPORTED FROM LANDLORD BULKHEAD

/ CEILING. PROVIDE ADDITIONAL AND / OR

SEPARATE FRAMING TO U/S OF

STRUCTURE.

4"

4" LIP, PAINTED MDF TO MATCH PT-2

WD-1

RECESSED SAMSUNG SCREEN ON COLUMN

3'-0

"

11"

3'-0

"

de

ca

l zo

ne

3'-0"

GLAZING 2'-0"

3'-0"

GLAZING

6" HIGH STAINLESS

STEEL U-CHANNEL

6" HIGH S.S. BASE,

MT-1

3'-6

"

1/8" REVEAL, PAINTED BLACK

1/2" ALUMINUM REVEAL

1/2" ALUMINUM REVEAL

1/8" REVEAL, PAINTED BLACK, LOCATION TO BE

CONFIRMED

G.C. TO PROVIDE SLIM

PROFILE WALL ANCHOR FOR

FLUSH FINISH BASED ON

VERTICAL MOUNT

1/2" ALUMINUM REVEAL

NEW

BANQUETTE

BULKHEAD

SOFFIT, PL-2

RETAIL FACE OF

STOREROOM

PARTITION

BACKLIT LED

GRAPHIC PANEL,

REFER TO

MILLWORK

DRAWINGS

NEW BANQUETTE

AREA, REFER TO

MILLWORK

DRAWINGS

EXISTING LETTER SIGNAGE TO

BE REMOVED AND REPLACED

WITH NEW, REFER TO

ELECTRICAL FOR POWER

CONNECTION FOR SIGNAGE

EXISTING STAINLESS STEEL

FINISH TO REMAIN

NEW GRILLE ENCLOSURE AND

CONCEALED POCKET DOOR,

FINISH WD-1. DOOR TO BE C/W

WITH NO VISIBLE HARDWARE

AND TOUCH LATCH

SEAM BETWEN POCKET DOOR

AND FINISH TO BE MINIMAL,

MAX. 1/4" WIDTH

NEW GRILLE ENCLOSURE

WITH CARRIER LOGO DESIGN

G.C. TO SUPPLY AND INSTALL

NEW 6" HIGH BREAKFORM S.S.

BASE, MT-1 TO GRILLE

ENCLOSURE. (TYP)

LINE OF DEMISING CAP/ FIRE

HOSE SURROUND

1

4

" THICK ACRYLIC LETTER

PAINTED PT-1 ADHERED TO SHOP

FINISH MDF TO MATCH CARRIER

COLOURS BELOW. REFER TO FA

FOR MORE INFORMATION.

3'-6

"1

0'-6

" T

O U

/S

O

F

PR

OP

OS

ED

B

UL

KH

EA

D

14

'-0

" T

O U

/S

O

F

MA

LL

C

EIL

IN

G

NEW 4" RUBBER BASE

THROUGHOUT @ RETAIL SIDE,

RB-1

GOOGLE FIXTURE BELL FIXTURETV FIXTURE

CHATR

DISPLAY

NEW 4" RUBBER BASE THROUGHOUT

AT RETAIL SIDE, RB-1

4"

6" 6" 1'-8"

2"

ACCESSORY

DISPLAY 5"

12

'-0

" T

O T

/O

E

XIS

TIN

G G

WB

W

AL

L

8

'-0

" T

O T

/O

E

XIS

TIN

G G

WB

NEW VERTICAL SIDE OF

BULKHEAD TO RECEIVE

FINISH WD-1

4'-0

" G

WB

E

XT

EN

SIO

N

TO

1

2'-0

" A

FF

.

2

MW0.5

RELOCATE EXISTING SECURITY CAMERA

TO COORDINATE WITH FIXTURE

4'-0

"

ADJUSTABLE LED LIGHT, REFER TO ELECTRICAL

6"

REFER TO MILLWORK DRAWINGS

FOR FINISHES OF ALL FIXTURE (TYPICAL)

WD-1

PT-1 PT-1

PL-2

9"

ACCESSORY

DISPLAY

ACCESSORY

DISPLAY

ACCESSORY

DISPLAY

APPLE FIXTURE

WD-1

1/2" U-CHANNEL BETWEEN NEW

STOREFRONT FINISH AND

EXISTING BULKHEAD

NEW STOREFRONT BULKHEAD

SOFFIT TO RECEIVE NEW

PAINT PT-2

PT-1

1'-6"

2'-0" 2'-0"

4'-0

"

10

'-6

" T

O U

/S

O

F

GW

B B

UL

KH

EA

D

GWB LIGHT COVE PAINTED PT-1,

REFER TO DWG. A3.0 FOR DETAIL

8'-0

" T

O U

/S

O

F

BA

NQ

UE

TT

E B

UL

KH

EA

D

PT-1

BACKWALL GWB BULKHEAD, PT-1

SUSPENDED GWB BULKHEAD BEYOND

GWB BULKHEAD, PT-1

2'-0"

IMPROVEMENTS & SIGN NOT TO BE

SUPPORTED FROM LANDLORD BULKHEAD

/ CEILING. PROVIDE ADDITIONAL AND / OR

SEPARATE FRAMING TO U/S OF

STRUCTURE.

RE

FE

R T

O D

WG

. 3

/A

4.0

1/2" ALUMINUM REVEAL

NEW RUBBER BASE PER FINISH SCHEDULE

ON A2.3

EXIST'G MALL

DEMISING WAL

TBOOTH

ADJACENT

RETAIL

SPACE

FINISHED FLOOR, REFER TO FINISHES

SCHEDULE FOR SPECIFICATION.

EXISTING BASE BUILDING

CEILING

GC TO INSTALL NEW

1

2

" THICK GYPSUM WALL

BOARD OVER EXISTING WALL FROM 8'-0"

A.F.F FINISHED TO 12''-0" A.F.F. WITH 'J' MOLD

CAP - TAPED, SPACKLED, SANDED, READY TO

RECEIVE NEW PAINT FINISH

U/S OF COVE CEILING @ 11'-1 3/4" AFF.

1

2

"

8'-0

" E

XIS

TIN

G G

WB

4'-0" N

EW

G

WB

INTERIOR ELEVATION

A4.0

DG

AS SHOWN

UN

IT

7

58

, 3

00

B

oro

ug

h D

rive

SC

AR

BO

RO

UG

H

TO

WN

C

EN

TR

E

Sca

rb

oro

ug

h, O

nta

rio

DESCRIPTION

DRAWING TITLE

PROJECT

SHEET NO.

SCALE:

DATE:

CHECKED BY:

DRAWN BY:

PROJECT NO.:

BY

JOHN E. GUSTAVSON ARCHITECT INC.

USE OR REPRODUCTION PROHIBITED

WITHOUT PRIOR WRITTEN PERMISSION.

THE GENERAL CONTRACTOR SHALL

REVIEW THE DOCUMENTS FOR

CONFORMANCE OF CODES AND

BYLAWS AND SHALL ADVISE THE

ARCHITECT OF ANY DISCREPANCIES HE

MAY NOTE. THE GENERAL CONTRACTOR

SHALL CHECK AND VERIFY ALL

DIMENSIONS AND REPORT ALL ERRORS

AND OMISSIONS TO THE DESIGNER, DO

REVISIONNO DATE

NOT SCALE THE DRAWINGS.

ALL RIGHTS RESERVED. PROPERTY OF

BYISSUED FORNO DATE

16224

DC

Unit 758, 300 Borough Drive, Scarborough, Ontario

SCARBOROUGH

TOWN CENTRE

ISSUED FOR TENDER

DGISSUED FOR COORDINATION101/16/17

January 27, 2017

JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,

VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203

www.gwa.ca

BWISSUED FOR LANDLORD REVIEW201/20/17

BWISSUED FOR BUILDING PERMIT301/27/17

BWISSUED FOR TENDER 404/03/17

SCALE:

2

INTERIOR ELEVATION

1/2" = 1'-0"

SCALE:

1

INTERIOR ELEVATION

1/2" = 1'-0" SCALE:

3

SECTION DETAIL

3" = 1'-0"

AutoCAD SHX Text
D-3
AutoCAD SHX Text
G-1
AutoCAD SHX Text
G-1
AutoCAD SHX Text
F-4
AutoCAD SHX Text
M-8
AutoCAD SHX Text
F-7
AutoCAD SHX Text
D-2
AutoCAD SHX Text
M-5
AutoCAD SHX Text
S-6
AutoCAD SHX Text
M-5
AutoCAD SHX Text
S-6
AutoCAD SHX Text
M-5
AutoCAD SHX Text
S-6
AutoCAD SHX Text
M-5
AutoCAD SHX Text
S-6
AutoCAD SHX Text
F-5
AutoCAD SHX Text
F-2

BACKLIT LED GRAPHIC PANEL,S-6

EXISTING DOOR AND FRAME TO

RECEIVE NEW FINISH PT-1

NEW SEAT AND SEAT BACK, M-6

EXISTING ALARM KEYPAD

EXISTING FIRE EXTINGUISHER

6'-3" OVERALL WIDTH

BUILT-IN BANQUETTE / GRAPHIC PANEL

PT-1

5"

MDF WITH FINISH PL-2

BACK WALL TO RECEIVE NEW FINISH

PT-1

4'-0

"4

'-0

"

8'-0

"

ADJUSTABLE LED LIGHT, TYP.

REFER TO ELECTRICAL

6"1'-6"

2'-0"

GWB LIGHT COVE PAINTED PT-1, TYP.

REFER TO DWG. A3.0 FOR DETAIL

PT-1

10

'-6

"1

'-6

"

SUSPENDED GWB BULKHEAD BEYOND

NEW BANQUETTE BULKHEAD SOFFIT

AND TWO SIDES FINISH WD-1

NEW BULKHEAD TO RECEIVE NEW

FINISH PT-1, TYP.

12

'-0

" T

O T

/O

E

XIS

TIN

G G

WB

W

AL

L

2

MW0.5

2'-6

"

REFER TO MILLWORK DRAWINGS

FOR FINISHES OF ALL FIXTURE (TYPICAL)

IMPROVEMENTS & SIGN NOT TO BE

SUPPORTED FROM LANDLORD BULKHEAD

/ CEILING. PROVIDE ADDITIONAL AND / OR

SEPARATE FRAMING TO U/S OF

STRUCTURE.

NEW GWB BULKHEAD TO RECEIVE NEW

FINISH PT-1

WD-1

1/2" ALUMINUM REVEAL BETWEEN FINISHES

WD-1 WD-1

4" RUBBER BASE, RB-14" RUBBER BASE, RB-1

1

1

2

"

5"

2'-0"

ENTRANCE TO

STORAGE ROOM

2'-11"

11

'-1

3

/4

"

7'-1

1

2

"

5'-9"

RETAIL FACE OF

STOREROOM PARTITION

BACKLIT LED GRAPHIC PANEL,

REFER TO MILLWORK

DRAWINGS

NEW BANQUETTE AREA, REFER

TO MILLWORK DRAWINGS

NEW VERTICAL SIDE OF BULKHEAD TO

RECEIVE NEW FINISH WD-1

NEW STOREFRONT BULKHEAD SOFFIT TO

RECEIVE NEW PAINT PT-2

BASE BUILDING DEMISING CAP BEYOND

RECESSED LCD SCREEN D-1, COMMERCIAL

QUALITY, PROVIDE BY OWNER

3'-6

"1

0'-6

" T

O U

/S

O

F

PR

OP

OS

ED

B

UL

KH

EA

D

NEW GRILLE ENCLOSURE, FINISH WD-1.

REFER TO MILLWORK DRAWINGS

FOR FINISHES OF ALL FIXTURE (TYPICAL)

IMPROVEMENTS & SIGN NOT TO BE

SUPPORTED FROM LANDLORD BULKHEAD

/ CEILING. PROVIDE ADDITIONAL AND / OR

SEPARATE FRAMING TO U/S OF

STRUCTURE.

PT-1 PT-1

PL-1

ACCESSORY

DISPLAY

ACCESSORY

DISPLAY

ACCESSORY

DISPLAY

ROGERS FIXTURE TV FIXTURE

2"

8"

4"APPLE FIXTURELG FIXTURE

7"

WD-1

G.C. TO SUPPLY AND INSTALL

NEW 6" HIGH BREAKFORM S.S.

BASE, MT-1 TO GRILLE

ENCLOSURE AND DEMISING

WALL. (TYP)

NEW 4" RUBBER BASE THROUGHOUT

AT RETAIL SIDE, RB-1

4'-0

" G

WB

E

XT

EN

SIO

N

TO

1

2'-0

" A

FF

.

4'-0

"

6"

PL-2

1'-6"

2'-0"2'-0"

BACKWALL BULKHEAD, PT-1

2'-0"

8

'-0

" T

O T

/O

E

XIS

TIN

G G

WB

4'-0

"

8'-0

" T

O U

/S

O

F

BA

NQ

UE

TT

E B

UL

KH

EA

D

ADJUSTABLE LED LIGHT, TYP.

REFER TO ELECTRICAL

GWB LIGHT COVE PAINTED PT-1, TYP.

REFER TO DWG. A3.0 FOR DETAIL

NEW 4" RUBBER BASE THROUGHOUT

@ RETAIL SIDE, RB-1

8

1

2

"

2

A3.0

1/2" U-CHANNEL BETWEEN NEW

STOREFRONT FINISH AND EXISTING

BULKHEAD

EXISTING DEMISING WALL TO RECLADDED, PL-1

14

'-0

" T

O U

/S

O

F

MA

LL

C

EIL

IN

G

SUSPENDED GWB BULKHEAD BEYOND

GRILLE ENCLOSURE

5"

DEMISING

WALL

NEW BANQUETTE BULKHEAD

SOFFIT, PL-2

12

'-0

" T

O T

/O

E

XIS

TIN

G G

WB

W

AL

L

RE

FE

R T

O D

WG

. 3

/A

4.0

1/2" ALUMINUM REVEAL

NEW STOREFRONT BULKHEAD

SOFFIT TO RECEIVE NEW PAINT

PT-2

1/2" ALUMINUM REVEAL

S.S. BASE, MT-1 ALL AROUND COLUMN

4'-0"

3'-0"

WD-1

1/8" REVEAL, PAINTED BLACK,

LOCATION TO BE CONFIRMED

10'-6" T

O U

/S

O

F

PR

OP

OS

ED

B

ULK

HE

AD

14'-0" T

O U

/S

O

F

MA

LL C

EILIN

G

3'-6"

3'-6"

NEW VERTICAL SIDE OF

BULKHEAD TO RECEIVE

FINISH WD-1

1/2" U-CHANNEL BETWEEN NEW

STOREFRONT FINISH AND

EXISTING BULKHEAD

SEAM BETWEEN POCKET DOOR

AND FINISH TO BE MAX. 1/4"

WIDTH

NEW CONCEALED DOOR FOR

SCREEN SERVICING, FINISH WD-1.

DOOR TO BE C/W TOUCH / LATCH

MAGNETIC HARDWARE

WD-1

WD-1

WD-1

NEW SEAT AND SEAT

BACK, M-6

BANQUETTE TO BE

FLUSHED WITH

ADJACENT GWB

B

A

N

Q

U

E

T

T

E

M

I

L

L

W

O

R

K

PT-1

HE

IG

HT

O

F B

AN

QU

ET

TE

TO

M

EE

T W

IT

H B

ULK

HE

AD

BANQUETTE TO BE FLUSHED

WITH ADJACENT GWB BULKHEAD

BACKLIT LED

GRAPHIC PANEL,S-6

PT-1

INTERIOR ELEVATION

A4.1

DG

AS SHOWN

UN

IT

7

58

, 3

00

B

oro

ug

h D

rive

SC

AR

BO

RO

UG

H

TO

WN

C

EN

TR

E

Sca

rb

oro

ug

h, O

nta

rio

DESCRIPTION

DRAWING TITLE

PROJECT

SHEET NO.

SCALE:

DATE:

CHECKED BY:

DRAWN BY:

PROJECT NO.:

BY

JOHN E. GUSTAVSON ARCHITECT INC.

USE OR REPRODUCTION PROHIBITED

WITHOUT PRIOR WRITTEN PERMISSION.

THE GENERAL CONTRACTOR SHALL

REVIEW THE DOCUMENTS FOR

CONFORMANCE OF CODES AND

BYLAWS AND SHALL ADVISE THE

ARCHITECT OF ANY DISCREPANCIES HE

MAY NOTE. THE GENERAL CONTRACTOR

SHALL CHECK AND VERIFY ALL

DIMENSIONS AND REPORT ALL ERRORS

AND OMISSIONS TO THE DESIGNER, DO

REVISIONNO DATE

NOT SCALE THE DRAWINGS.

ALL RIGHTS RESERVED. PROPERTY OF

BYISSUED FORNO DATE

16224

DC

Unit 758, 300 Borough Drive, Scarborough, Ontario

SCARBOROUGH

TOWN CENTRE

ISSUED FOR TENDER

DGISSUED FOR COORDINATION101/16/17

January 27, 2017

JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,

VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203

www.gwa.ca

BWISSUED FOR LANDLORD REVIEW201/20/17

BWISSUED FOR BUILDING PERMIT301/27/17

BWISSUED FOR TENDER 404/03/17

SCALE:

2

INTERIOR ELEVATION

1/2" = 1'-0"

SCALE:

1

INTERIOR ELEVATION

1/2" = 1'-0" SCALE:

3

INTERIOR ELEVATION

1/2" = 1'-0" SCALE:

4

[M-6] BANQUETTE - ISOMETRIC DIAGRAM

NTS

AutoCAD SHX Text
S-6
AutoCAD SHX Text
M-6
AutoCAD SHX Text
M-5
AutoCAD SHX Text
S-6
AutoCAD SHX Text
M-5
AutoCAD SHX Text
S-6
AutoCAD SHX Text
M-5
AutoCAD SHX Text
S-6
AutoCAD SHX Text
M-8
AutoCAD SHX Text
F-6
AutoCAD SHX Text
D-2
AutoCAD SHX Text
F-3
AutoCAD SHX Text
F-1
AutoCAD SHX Text
D-1

QR

A

FE

11'-5"

EXISTING PENDANT FIXTURE TO

BE REMOVED, TYPICAL.

REFER TO ELECTRICAL

EXISTING FLUORESCENT LIGHT

FIXTURES TO BE REMOVED,

TYPICAL. REFER TO ELECTRICAL

EXISTING GWB BULKHEAD TO BE

REMOVED

EXISTING LOWER BULKHEAD TO BE

REMOVED

EXISTING EMERGENCY LIGHT

TO REMAIN

EXISTING TRANSFORMER

TO REMAIN

EXISTING PENDANT FIXTURE TO

BE REMOVED, TYPICAL

EXISTING TRACK AND RECESSED

LIGHTING TO BE REMOVED,

TYPICAL.

REFER TO ELECTRICAL

EXISTING SPRINKLERS ON BULKHEAD TO BE

RELOCATED AS REQUIRED, TYPICAL.

REFER TO MECHANICAL

EXISTING ILLUMINATED HALO-LIT

SIGNAGE TO BE REMOVED AND

REPLACED WITH NEW

EXISTING GWB BULKHEAD TO BE

REMOVED

EXISTING GRILLE DOOR AND

TRACK TO BE REMOVED, TYP.

EXISTING FLUORESCENT

FIXTURE TO BE REMOVED

EXISTING LAMINATED BULKHEAD

TO BE REMOVED

EXISTING T-BAR CEILING

TO REMAIN

11'-0" AFF

OPEN

OPEN

EXISTING DOWNLIGHT TO BE

REMOVED, TYP.

REFER TO MECHANICAL DRAWINGS FOR

RELOCATION OF ALL HVAC EQUIPMENT AND

SPRINKLERS

REFLECTED CEILING PLAN

DEMOLITION

A6.0

DG

AS SHOWN

SCALE:

1

DEMOLITION REFLECTED CEILING PLAN

3/8" = 1'-0"

UN

IT

7

58

, 3

00

B

oro

ug

h D

rive

SC

AR

BO

RO

UG

H

TO

WN

C

EN

TR

E

Sca

rb

oro

ug

h, O

nta

rio

DESCRIPTION

DRAWING TITLE

PROJECT

SHEET NO.

SCALE:

DATE:

CHECKED BY:

DRAWN BY:

PROJECT NO.:

BY

JOHN E. GUSTAVSON ARCHITECT INC.

USE OR REPRODUCTION PROHIBITED

WITHOUT PRIOR WRITTEN PERMISSION.

THE GENERAL CONTRACTOR SHALL

REVIEW THE DOCUMENTS FOR

CONFORMANCE OF CODES AND

BYLAWS AND SHALL ADVISE THE

ARCHITECT OF ANY DISCREPANCIES HE

MAY NOTE. THE GENERAL CONTRACTOR

SHALL CHECK AND VERIFY ALL

DIMENSIONS AND REPORT ALL ERRORS

AND OMISSIONS TO THE DESIGNER, DO

REVISIONNO DATE

NOT SCALE THE DRAWINGS.

ALL RIGHTS RESERVED. PROPERTY OF

BYISSUED FORNO DATE

16224

DC

Unit 758, 300 Borough Drive, Scarborough, Ontario

SCARBOROUGH

TOWN CENTRE

ISSUED FOR TENDER

DGISSUED FOR COORDINATION101/16/17

January 27, 2017

JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,

VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203

www.gwa.ca

BWISSUED FOR LANDLORD REVIEW201/20/17

BWISSUED FOR BUILDING PERMIT301/27/17

BWISSUED FOR TENDER 404/03/17

NORTH

AutoCAD SHX Text
FHC
AutoCAD SHX Text
B

QR

A

FE

4 1/2"

4'-10"

2'-0

"

10'-6" AFF

10'-6" AFF

NEW LIGHT FIXTURE MOUNT IN

EXISTING T-BAR CEILING AT

WORKROOM

ALL NEW TRACK LIGHT FIXTURES TO

BE SUSPENED @ 10'-6" A.F.F. ENSURE

NO INTERFERENCE WITH CEILING

DIFFUSERS

EXISTING CEILING OPEN TO STRUCTURE.

CLEAN AND PAINT FLAT BLACK FROM 12'-0" A.F.F.

NEW SLIDING GRILLE TRACK TO

REPLACE EXISTING. RECESS TRACK TO

FULLY FLUSH WITH UNDERSIDE OF

BULKHEAD. ENSURE MINIMUM 4"

CLEARANCE ON EITHER SIDE OF TRACK

ALONG ENTIRE TRACK LENGTH.

NEW LED DOWNLIGHT TO BE RECESSED

WITHIN NEW GWB BULKHEAD.

REFER TO ELECTRICAL

REFER TO MECHANICAL DRAWINGS FOR

HVAC LAYOUT AND NEW / RELOCATED

SPRINKLER LOCATIONS.

LED FIXTURE WITHIN COVE.

REFER TO ELECTRICAL

T

Y

P

.

T

Y

P

.

PT-2

PT-1

7

'

-

1

1

"

NEW ILLUMINATED HALO-LIT SIGNAGE

MOUNTED TO STOREFRONT BULKHEAD. REFER

TO ELEVATIONS AND SIGN CONTRACTORS

SHOP DRAWINGS FOR DETAILS

GWB BULKHEAD TO BE SUSPENDED

FROM STRUCTURE ABOVE WITH H/D

AIRCRAFT CABLE @ 10'-6" A.F.F. REFER

TO DWG. A3.0 FOR CONSTRUCTION AND

FINISH DETAILS. G.C. TO ENSURE ALL

WIRINGS TO FULLY CONCEALED FROM

ALL VIEW.

NEW BULKHEAD @ 10'-6" A.F.F. TO BE

PAINTED TO MATCH PT-2

TRACK LIGHT FIXTURES IN SUSPENDED

BULKHEADS TO BE CONNECTED TO ONE

SWITCH SUCH THAT THEY FUNCTION

INDEPENDENTLY OF GENERAL RETAIL

LIGHTING - REFER TO ELECTRICAL

ENGINEER'S DRAWINGS FOR DETAILS.

SUITABLE ACCESS MUST BE PROVIDED BY

TENANT TO ALL EQUIPMENT CONCEALED BY

HIS WORK WHICH REQUIRES ROUTINE

MAINTENANCE OF CONTROL ADJUSTMENT.

REFER TO ENGINEER DRAWINGS FOR

LOCATIONS OF ACCESS PANELS IN NEW

CEILING

STOCK ROOM LIGHTING TO BE CONTROLLED

ON A OCCUPANCY SENSOR.

NEW LAMINATED BULKHEAD TO BE

PAINTED TO MATCH PT-2

5

A3.0

REFER TO ELECTRICAL DRAWINGS FOR

ALL LIGHTING REQUIREMENTS.

REFER TO STRUCTURAL DRAWINGS

FOR STRUCTURAL SUPPORT OF NEW

DOOR TRACK

G.C. TO INSTALL 8" W x 8" H (INTERIOR)

GWB LIGHT COVE TO 11'-1 3/4" A.F.F. AT

RETAIL SIDE OF PERIMETER WALL, TYP.

REFER TO DWG. A3.0

G.C. TO INSTALL 8" W x 8" H

(INTERIOR) GWB LIGHT COVE TO

11'-1 3/4" A.F.F. AT RETAIL SIDE OF

PERIMETER WALL.

REFER TO DWG. A3.0

G.C. TO INSTALL 8" W x 8" H (INTERIOR) GWB

LIGHT COVE TO 11'-1 3/4" A.F.F. AT RETAIL

SIDE OF PERIMETER WALL.

REFER TO DWG. A3.0

8'-0" AFF

15'-0"

2'-0"

1'-1

0"

2'-0

"

2'-0

"

1'-10"

TYP.

4'-0

"2

'-0

"4

'-0

"4

'-0

"4

'-0

"4

'-0

"4

'-0

1

/2

"4

'-0

"4

'-0

"1

'-1

"

39

'-4

1

/2

"

4'-0"1'-8" 1'-8" 1'-10"

TYP.

4'-0

"2

'-0

"4

'-0

"4

'-0

"4

'-0

"

4

'

-

0

"

PT-1

2

'-

3

"

4

'-

0

"

1

'

-

3

1

/

2

"

2

'

-

8

"

3

'

-

1

1

/

2

"

1

'

-

5

"

3

'

-

5

"

2

'

-

9

1

/

2

"

2'-0" 2'-0"

11 '-1 3/4" AFF

PT-1

10'-6" AFFPT-1

8'-0" AFF

WD-1

OPEN

TYP. TYP.

10'-6" AFF

PT-1

NEW TRACK LIGHT FIXTURES SECURED

WITHIN SUSPENDED BULKHEAD ABOVE.

REFER TO MILLWORK DETAILS FOR

ADDITIONAL INFORMATION

GWB BULKHEAD TO BE SUSPENDED

FROM STRUCTURE ABOVE WITH H/D

AIRCRAFT CABLE @ 10'-6" A.F.F.

BULKHEAD TO BE SUSPENDED

DIRECTLY ABOVE MILLWORK

FIXTURES. REFER TO DWG. A3.0 FOR

CONSTRUCTION AND FINISH DETAILS.

G.C. TO ENSURE ALL WIRINGS TO

FULLY CONCEALED FROM ALL VIEW.

10'-6" AFF

PT-1

11 '-1 3/4" AFF

PT-1

LED FIXTURE WITHIN COVE, TYP.

REFER TO DWG. A3.0 & ELECTRICAL

LED FIXTURE WITHIN COVE, TYP.

REFER TO DWG. A3.0 & ELECTRICAL

LED FIXTURE WITHIN COVE, TYP.

REFER TO DWG. A3.0 & ELECTRICAL

DATA POWER INTERGRATION BOX IN

CEILING. REFER TO ELECTRICAL

7'-4 1/2"

ALL NEW OR RELOCATED SPRINKLERS,

REFER TO MECHANICAL. TYP.

NEW DUAL-VIEW FOOT COUINTER SENSOR

IN BULKHEAD, REFER TO ELECTRICAL

5'-3

"5

'-3

"

1'-6

"

5'-3

"5

'-3

"

10

'-6

"1

0'-6

"

6'-0

"6

'-0

"6

'-0

"

4

'

-

0

"

4

'

-

0

"

2'-3

"2

'-3

"2

'-3

"2

'-3

"2

'-3

"

6

'

-

0

"

2'-6" 6'-0" 2'-6"

2'-6

"

2

'

-

6

1

/

2

"

3

'

-

3

"

4

'-

8

"

4 1/2"

8"

1/2" ALUMINUM REVEAL

1/2" ALUMINUM REVEAL

4

A3.0

1

A3.0

2

A3.0

REFER TO MILLWORK PACKAGE FOR

CEILING DETAIL IN BANQUETTE SEATING

NEW GWB CEILING, PAINTED

1. REFER TO SPRINKLER DRAWINGS FOR ALL SPRINKLER HEAD

LOCATIONS.

2. RUN ALL SPRINKLER LINES IN JOIST SPACE - AS REQUIRED.

3. SPRINKLER CONTRACTOR TO BE RESPONSIBLE FOR RELOCATING

ALL EXISTING SPRINKLER HEADS INTERFERING WITH NEW LIGHT,

MECHANICAL DUCT AND BULKHEAD LOCATIONS - COORDINATE

WITH ALL TRADES PRIOR TO INSTALLATION.

4. CONTRACTOR TO CHECK THE DRAWING AGAINST EXISTING SITE

CONDITIONS BEFORE ISSUING TENDER PRICE.

5. SPRINKLER CONTRACTOR TO PROVIDE SPRINKLERS IN NEW T-BAR

OR GWB AS REQUIRED TO MEET ALL CODE REQUIREMENTS.

SPRINKLER CONTRACTOR TO ENSURE ALL BACK AREAS (STOCK

ROOMS, OFFICES, WASHROOMS) ARE SPRINKLERED AND PROVIDE

SPRINKLERS TO U/S OF ALL MEZZANINES.

6. CONTRACTOR TO REVIEW ELECTRICAL ENGINEER'S DRAWINGS IN

CONJUNCTION WITH THIS LIGHTING PLAN AND DETAILS.

7. CONTRACTOR TO REPORT ANY/ALL DISCREPANCIES OR

CONFLICTS TO THE CONSULTANTS IMMEDIATELY FOR

RESOLUTION.

8. CONTRACTOR TO CONFIRM THAT ANY EXISTING LIGHTING

FIXTURES BEING REUSED ARE IN GOOD WORKING ORDER.

9. CONTRACTOR TO CLEAN RE-LENS AND RE-LAMP ALL EXISTING

FIXTURES BEING REUSED.

10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR QUANTITY

TAKEOFFS AND FOR ORDERING ALL NECESSARY ACCESSORY

PARTS REQUIRED FOR PROPER INSTALLATION OF THE SPECIFIED

SYSTEM (NEW OR REPLACEMENT) FOR COMPLETION WITHIN THE

CONTRACTED TIME FRAME.

11. CONTRACTOR SHALL VERIFY ON SITE, LIGHTING FIXTURE HEIGHTS

ON ELEVATIONS AND LIGHTING PLAN WITH CLIENT

REPRESENTATIVE/PROJECT MANAGER PRIOR TO INSTALLATION ON

SITE.

12. ALL LIGHT FIXTURES AND EQUIPMENT USED SHALL MEET ANY AND

ALL APPLICABLE CODES OF GOVERNING BODIES HAVING

JURISDICTION, INCLUDING BUT NOT LIMITED TO LOCAL, CITY AND

PROVINCIAL CODES/BY-LAWS AS WELL AS HEALTH DEPARTMENT

REGULATIONS.

13. CONTRACTOR RESPONSIBLE FOR ORDERING ALL ELECT.

EQUIPMENT SHALL, UPON AWARD OF CONTRACT, DETERMINE

DELIVERY TIMES ETC WITH MANUFACTURERS. CONTRACTOR

SHALL BE SOLELY RESPONSIBLE FOR ENSURING DELIVERY OF

LIGHTS ETC. AT REQ'D TIME. NO SUBSTITUTIONS WILL BE

APPROVED ARISING FROM THE CONTRACTOR NOT ORDERING

EQUIPMENT AND/OR SUPPLIES IN TIME.

14. ALL FIXTURES INSTALLED MUST BE PER JOB SPECIFICATIONS. ANY

SUBSTITUTIONS WHICH MAY BE REQUIRED DUE TO EXTENDED

DELIVER DATES ETC., MUST BE SUBMITTED TO CLIENT FOR

WRITTEN APPROVAL PRIOR TO ORDER OR INSTALLING THE

SUBSTITUTE FIXTURES.

15. THE SUPPORTS REQUIRED FOR MOUNTING AND INSTALLATION OF

RECESSED LIGHT FIXTURES SHALL BE SUPPLIED AND INSTALLED

BY THE ELECTRICAL CONTRACTOR. THE SUPPORT SHALL BE

ATTACHED TO THE STRUCTURE. THE CEILING SYSTEM SHALL NOT

BE A MEANS OF SUPPORT.

REFLECTED CEILING PLAN NOTES

16. SURFACE MOUNTED FIXTURES EXCEEDING 20lbs SHALL BE

INDEPENDENTLY SUPPORTED FROM THE STRUCTURE.

17. PROVIDE ADDITIONAL SUPPORTS, HANGERS, ETC., AS

REQUIRED TO SUPPORT FIXTURES MOUNTED UNDER

DUCTWORK. THE FIXTURE SUPPORT SHALL NOT BE

ATTACHED TO EITHER THE DUCTWORK OR THE DUCTWORK

SUPPORTS.

18. CONTRACTOR TO PAINT OUT ALL SUPPLY/RETURN AIR

GRILLES/DIFFUSERS TO MATCH ADJACENT CEILING/WALL

FINISH.

19. REFER TO ELECTRICAL ENGINEERING DRAWINGS FOR

EMERGENCY LIGHTING, EXIT SIGNS AND FIRE PULL STATION

LOCATIONS AND DETAILED ELECTRICAL SPECIFICATIONS.

20. TILES TO BE PAINTED BEFORE BEING INSTALLED IN GRID. G.C.

TO ENSURE 100% COVERAGE OF ALL CEILING TILES WITH

PAINT FINISH.

21. ALL EQUIPMENT TO BE VERIFIED BY CLIENT PRIOR TO

INSTALLATION.

22. FIT SUPPLY AND RETURN AIR TO SUIT NEW

LAYOUT/OCCUPANCY EQUIPMENT LOAD BALANCE SYSTEM.

SEE MECHANICAL CONTRACTORS DRAWINGS FOR DETAILS.

23. CEILING HEIGHTS ARE NOTED FOR EACH AREA, WHERE

THOSE CANNOT BE ACHIEVED, GENERAL CONTRACTOR TO

NOTIFY ARCHITECT IMMEDIATELY.

24. REFLECTED CEILING PLAN MUST BE USED IN CONJUNCTION

WITH ALL SECTIONS, ELEVATIONS, AND DETAILS FOR A FULL

UNDERSTANDING OF CEILING HEIGHTS REQUIRED.

25. GENERAL CONTRACTOR TO INSTALL ELECTRICAL

CONNECTIONS FOR SIGNAGE (WHERE APPLICABLE).

26. GENERAL CONTRACTOR TO SUPPLY FIRE STOPPING AS

REQUIRED BY CODE.

27. REFER TO MECHANICAL ENGINEER'S DRAWINGS FOR ALL

LOCATIONS OF DUCTWORK, SUPPLY/RETURN AIR GRILLES

AND DIFFUSERS, FIRE DAMPERS AND ANY OTHER HVAC

EQUIPMENT.

28. ALL HEADS IN HARD CEILING (I.E.: GYPSUM BOARD) TO BE

FULLY RECESSED WITH COVERS PAINTED TO MATCH.

29. MECHANICAL CONTRACTOR TO PROVIDE DUCT/HVAC LAYOUT

TO SUIT REFLECTED CEILING PLAN LAYOUT & REFLECTED

CEILING PLAN BALANCE SYSTEM.

30. DO NOT SCALE DRAWINGS.

31. G.W.B. CONTRACTOR TO WORK IN CONJUNCTION WITH

FLOORING CONTRACTOR TO ENSURE CRITICAL ALIGNMENT

OF BULKHEAD WHERE APPLICABLE.

32. G.W.B. CONTRACTOR TO CUT NEW OPENINGS IN GWB CEILING

WITH FRAMING AS REQUIRED TO SUPPORT NEW AND

RELOCATED RECESSED LIGHT FIXTURES. REFER TO

REFLECTED CEILING PLAN FOR LOCATIONS.

33. G.W.B. CONTRACTOR TO PATCH AND REPAIR EXISTING

CEILING WHERE DEMOLITION HAS OCCURRED.

34. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES IN

THE JURISDICTION WHERE THE WORK IS LOCATED.

MECHANICAL NOTES

1. ALL WORK SHALL CONFORM TO C.S.A., NATIONAL BUILDING CODE AND

LOCAL MUNICIPAL AND PROVINCIAL LAWS AND REGULATIONS.

2. MECHANICAL CONTRACTOR TO BE RESPONSIBLE FOR ENSURING ALL

ENCLOSED ROOMS AND BACK AREAS (FITTING ROOMS, STOCK ROOMS,

OFFICES) HAVE ADEQUATE AIR SUPPLY AND RETURN VENTILATION.

3. BALANCING OF DIFFUSERS AND GRILLES MUST BE PERFORMED ONLY BY

A PERSON WHO IS THOROUGHLY EXPERIENCED IN THE OPERATION OF A

SYSTEM OF THIS NATURE AND HAS DEMONSTRATED QUALIFICATIONS BY

HAVING SUCCESSFULLY DONE SO PRIOR TO THIS INSTALLATION. THE

COSTING OF ALL BALANCING SHALL BE INCLUDED IN THE TENDER PRICE.

REFLECTED CEILING PLAN LEGEND

SYMBOL CEILING TYPE DESCRIPTION

LIGHT FIXTURE LEGEND

SYMB.

NEW RECESSED LED DOWNLIGHT FIXTURE

· REFER TO ELECTRICAL

QTY. SUPPLIER:DESCRIPTION

NEW TRACK LIGHT FIXTURES

· REFER TO ELECTRICAL

GENERAL NOTES

1. REFER TO ELELCTRICAL FOR ALL LIGHTING REQUIREMENTS.

2. CONTRACTOR TO SUPPLY 10 EXTRA LIGHT OF EACH TYPE OF LED LAMPS FOR FUTURE USE.

3. LIGHTING INSTALLER TO DIRECT HEADS TOWARD DISPLAY, AS PER MANAGER'S INSTRUCTION.

GWB BULKHEAD

· 5/8" GYPSUM WALL BOARD CONSTRUCTION

NEW LED LIGHT FIXTURE

· REFER TO ELECTRICAL

NEW T-BAR CEILING AND TILES

· ARMSTRONG DUNE FINE TEXTURED #1773 2'x4'x5/8" TILE - WHITE

CEILING / WALL MOUNTED SELF POWER LED EXIT SIGN

· REFER TO ELECTRICAL

NEW LED RGB COVE LIGHT

· REFER TO ELECTRICAL

1. ALL WORK AFFECTING LL BASE BUILDING SUCH AS SPRINKLER SYSTEM,

HVAC SYSTEM, ROOF WORK, TILE WORK OUTSIDE OF LEASED AREA OR

ELECTRICAL WORK OUTSIDE OF LEASED AREA WILL BE REQUIRED TO BE

PERFORMED BY A LL DESIGNATED OR LL APPROVED CONTRACTOR AND

BE ENGAGED BY THE TENANT.

2. ALL DESIGN COMPONENTS TO MEET CURRENT SEISMIC RESTRAINT

CODES.

3. ALL OPEN AREAS AND STRUCTURAL SUPPORTS ABOVE OPEN CEILING TO

BE REPAINTED FLAT BLACK.

GENERAL NOTES

EMERGENCY BATTERY UNIT

· REFER TO ELECTRICAL

EMERGENCY SINGLE REMOTE RECESSED LIGHT

· REFER TO ELECTRICAL

PER ELECT.

PER ELECT.

PER ELECT.

PER ELECT.

PER ELECT.

PER ELECT.

PER ELECT.

UPRIGHT / CONCEALED SPRINKLER HEAD

· REFER TO MECHANICAL

PER MECH.

NEW PENDANT LIGHT @ 9'-6" AFF.

· REFER TO ELECTRICAL

PER ELECT.

REFLECTED CEILING PLAN

A6.1

DG

AS SHOWN

SCALE:

1

REFLECTED CEILING PLAN

3/8" = 1'-0"

UN

IT

7

58

, 3

00

B

oro

ug

h D

rive

SC

AR

BO

RO

UG

H

TO

WN

C

EN

TR

E

Sca

rb

oro

ug

h, O

nta

rio

DESCRIPTION

DRAWING TITLE

PROJECT

SHEET NO.

SCALE:

DATE:

CHECKED BY:

DRAWN BY:

PROJECT NO.:

BY

JOHN E. GUSTAVSON ARCHITECT INC.

USE OR REPRODUCTION PROHIBITED

WITHOUT PRIOR WRITTEN PERMISSION.

THE GENERAL CONTRACTOR SHALL

REVIEW THE DOCUMENTS FOR

CONFORMANCE OF CODES AND

BYLAWS AND SHALL ADVISE THE

ARCHITECT OF ANY DISCREPANCIES HE

MAY NOTE. THE GENERAL CONTRACTOR

SHALL CHECK AND VERIFY ALL

DIMENSIONS AND REPORT ALL ERRORS

AND OMISSIONS TO THE DESIGNER, DO

REVISIONNO DATE

NOT SCALE THE DRAWINGS.

ALL RIGHTS RESERVED. PROPERTY OF

BYISSUED FORNO DATE

16224

DC

Unit 758, 300 Borough Drive, Scarborough, Ontario

SCARBOROUGH

TOWN CENTRE

ISSUED FOR TENDER

DGISSUED FOR COORDINATION101/16/17

January 27, 2017

JOHN E. GUSTAVSON ARCHITECT4th FLOOR - 576 SEYMOUR ST.,

VANCOUVER, BC, CANADA V6B 3K1P: 604-687-2511 F: 604-687-4203

www.gwa.ca

BWISSUED FOR LANDLORD REVIEW201/20/17

BWISSUED FOR BUILDING PERMIT301/27/17

BWISSUED FOR TENDER 404/03/17

NORTH

AutoCAD SHX Text
FHC
AutoCAD SHX Text
B
AutoCAD SHX Text
DPI
AutoCAD SHX Text
B

KB03APR2017ISSUED FOR TENDER-R102

AW28FEB2017ISSUED FOR TENDER01

387 Richmond Street East

Toronto Canada M5A 1P6

www.sld.com

t 416.367.1999

f 416.367.5451

DRAWING NUMBER:

DOCKET:

SHEET SIZE:

DATE:

SCALE:

DRAWN BY:

CHECKED BY:

SL16790

ARCH D

DRAWING NAME:

PROJECT:

CLIENT:

CONSULTANT

GLENTEL

TBOOTH WIRELESS

SCARBOROUGH TOWN CENTRE

UNIT #758

300 BOROUGH DR

SCARBOROUGH,ON

M1P 4P5

ISSUES AND REVISIONS ( ): BY:DATE:

1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS

ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX

DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN

WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI

LACROIX.

2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT

ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING

WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE

CONTRACTOR'S EXPENSE.

3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S

DRAINGS IN THE CONTRACT.

4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.

5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE

DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.

6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN

CONFORMITY WITH THE BUILDING CODES IN FORCE.

7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE

CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE

TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL

EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.

GENERAL NOTES:

28-02-2017

as noted bw

aw

MILLWORK DETAILS

COVER PAGE

ISSUED FOR

TENDER

DRAWINGS NOT FOR

CONSTRUCTION

MW-00

TBOOTH WIRELESS

SCARBOROUGH TOWN CENTRE

MILLWORK DETAILS

MW-0.0 COVER SHEET

MW-1.0 M-1 CARRIER LOGO WALL

MW-2.0 M-2 SMALL DISPLAY TABLE

MW-3.0 M-3 LARGE DISPLAY TABLE

MW-4.0 M-4 CASH TABLE

MW-5.0 M-5 ACCESSORIES DISPLAY

MW-6.0 M-6 BANQUETTE W/ BACKLIT GRAPHICS PANEL

MW-7.0 M-7 CUSTOM OTTOMAN

MW-8.0 M-8 CARRIER DISPLAY

B

C

A3

A4

A2

A1

B

B

B

C

C

C

A5

CARRIER DESCRIPTION#

ROGERS ROGERS REDA1

BELL PANTONE PMS301CA2

FIDO 100% BLACK, PANTONE 012CA3

VIRGIN 100% BLACK, VSPOT REDA4

CHATR PURPLE PMS2597C, ORANGE PMS144SA5

SCALE:

1

MW-1.0

[M-1] ELEVATION OF CARRIER LOGO WALL

1" = 1'-0"

KB03APR2017ISSUED FOR TENDER-R102

AW28FEB2017ISSUED FOR TENDER01

387 Richmond Street East

Toronto Canada M5A 1P6

www.sld.com

t 416.367.1999

f 416.367.5451

DRAWING NUMBER:

DOCKET:

SHEET SIZE:

DATE:

SCALE:

DRAWN BY:

CHECKED BY:

SL16790

ARCH D

DRAWING NAME:

PROJECT:

CLIENT:

CONSULTANT

GLENTEL

TBOOTH WIRELESS

SCARBOROUGH TOWN CENTRE

UNIT #758

300 BOROUGH DR

SCARBOROUGH,ON

M1P 4P5

ISSUES AND REVISIONS ( ): BY:DATE:

1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS

ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX

DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN

WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI

LACROIX.

2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT

ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING

WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE

CONTRACTOR'S EXPENSE.

3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S

DRAINGS IN THE CONTRACT.

4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.

5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE

DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.

6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN

CONFORMITY WITH THE BUILDING CODES IN FORCE.

7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE

CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE

TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL

EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.

GENERAL NOTES:

28-02-2017

as noted bw

aw

MILLWORK DETAILS

[M-1]

CARRIER LOGO WALL

ISSUED FOR

TENDER

DRAWINGS NOT FOR

CONSTRUCTION

MW-1.0

SCALE:

2

MW-1.0

[M-1] CARRIER LOGO WALL - DETAILED ELEVATION

1" = 1'-0" SCALE:

3

MW-1.0

[M-1] CARRIER LOGO WALL - DIMENSION ELEVATION

1" = 1'-0"

SCALE:

4

MW-1.0

[M-1] CARRIER LOGO WALL - SECTION PLAN

1 1/2" = 1'-0" SCALE:

5

MW-1.0

[M-1] CARRIER LOGO WALL - DETAIL OF ACRYLIC BOXES

1 1/2" = 1'-0"

AutoCAD SHX Text
MW1.0
AutoCAD SHX Text
2
AutoCAD SHX Text
MW1.0
AutoCAD SHX Text
3
AutoCAD SHX Text
DOTTED INDICATES CARRIER LOGOS + NICHES. REFER TO DETAIL:[5:MW-1.0] FOR MORE INFORMATION
AutoCAD SHX Text
WD-1
AutoCAD SHX Text
DIRECTION OF WOOD GRAIN
AutoCAD SHX Text
POCKET DOOR FOR SECURITY GRILLE COMPLETE WITH INVISIBLE HARDWARE
AutoCAD SHX Text
6"BREAKFORM METAL BASE TO MATCH
AutoCAD SHX Text
MT-1
AutoCAD SHX Text
MW1.0
AutoCAD SHX Text
4
AutoCAD SHX Text
WOOD VENEER SHEET SIZE (3X11)
AutoCAD SHX Text
SEAM OF VENEER (VENEER TO BE BOOK MATCHED)
AutoCAD SHX Text
WOOD VENEER
AutoCAD SHX Text
WD-1
AutoCAD SHX Text
CUSTOM BACKLIT ACRYLIC BOXES RECESSED INTO A NICHE REFER TO DETAIL: [5:MW-1.0] FOR FINISH + SIZE
AutoCAD SHX Text
CUSTOM BACKLIT ACRYLIC BOXES SURFACE MOUNTED REFER TO DETAIL: [5:MW-1.0] FOR FINISH + SIZE
AutoCAD SHX Text
NOTE: ENSURE THAT ELECTRICAL SUPPLY DOES NOT INTERFERE WITH GRILLE BEHIND
AutoCAD SHX Text
14" THICK ACRYLIC LETTER WITH TRANSLUCENT VINYL ADHERED TO "ACRYLIC BOX (BACKLIT) 14"ACRYLIC BOX (BACKLIT) TO MATCH CARRIER COLOURS. REFER TO FA FOR MORE INFORMATION. FA FOR MORE INFORMATION. FOR MORE INFORMATION. REFER TO CHART PROVIDED FOR LIST OF CARRIER LOGOS.
AutoCAD SHX Text
CARRIER LOGO
AutoCAD SHX Text
SHAPE A:
AutoCAD SHX Text
SHAPE B:
AutoCAD SHX Text
SHAPE C:
AutoCAD SHX Text
1/2"THICK ACRYLIC BOX WHITE FROSTED (70%) TO MATCH [PT-1], BACKLIT AS DETAILED
AutoCAD SHX Text
1/2"THICK ACRYLIC BOX WHITE FROSTED (70%) TO MATCH [PT-1], BACKLIT AS DETAILED

SCALE:

1

MW-2.0

[M-2] SMALL DISPLAY TABLE - PLAN

1 1/2" = 1'-0"

KB03APR2017ISSUED FOR TENDER-R102

AW28FEB2017ISSUED FOR TENDER01

387 Richmond Street East

Toronto Canada M5A 1P6

www.sld.com

t 416.367.1999

f 416.367.5451

DRAWING NUMBER:

DOCKET:

SHEET SIZE:

DATE:

SCALE:

DRAWN BY:

CHECKED BY:

SL16790

ARCH D

DRAWING NAME:

PROJECT:

CLIENT:

CONSULTANT

GLENTEL

TBOOTH WIRELESS

SCARBOROUGH TOWN CENTRE

UNIT #758

300 BOROUGH DR

SCARBOROUGH,ON

M1P 4P5

ISSUES AND REVISIONS ( ): BY:DATE:

1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS

ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX

DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN

WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI

LACROIX.

2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT

ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING

WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE

CONTRACTOR'S EXPENSE.

3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S

DRAINGS IN THE CONTRACT.

4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.

5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE

DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.

6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN

CONFORMITY WITH THE BUILDING CODES IN FORCE.

7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE

CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE

TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL

EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.

GENERAL NOTES:

28-02-2017

as noted bw

aw

MILLWORK DETAILS

[M-2]

SMALL DISPLAY TABLE

ISSUED FOR

TENDER

DRAWINGS NOT FOR

CONSTRUCTION

MW-2.0

SCALE:

2

MW-2.0

[M-2] SMALL DISPLAY TABLE - FRONT ELEVATION

1 1/2" = 1'-0" SCALE:

3

MW-2.0

[M-2] SMALL DISPLAY TABLE - SIDE ELEVATION

1 1/2" = 1'-0"

SCALE:

4

MW-2.0

[M-2] SMALL DISPLAY TABLE - SECTION ELEVATION

1 1/2" = 1'-0" SCALE:

5

MW-2.0

[M-2] SMALL DISPLAY TABLE - PLAN SECTION

1 1/2" = 1'-0"

AutoCAD SHX Text
MW-2.0
AutoCAD SHX Text
3
AutoCAD SHX Text
12" WIDE SLOTS C/W BLACK BRUSH SEAL
AutoCAD SHX Text
DOTTED LINE DENOTES RAW METAL STRIP UNDER PLASTIC LAMINATE
AutoCAD SHX Text
18" THK. EARTH MAGNETS WITHIN REMOVABLE LABELS
AutoCAD SHX Text
TOP OF PHONE DISPLAY TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
MW-2.0
AutoCAD SHX Text
2
AutoCAD SHX Text
MW-2.0
AutoCAD SHX Text
4
AutoCAD SHX Text
DISPLAY SIGNAGE BY CLIENT
AutoCAD SHX Text
SIDE OF PHONE DISPLAY TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
CABINET DOORS OF PHONE DISPLAY TO RECEIVE FINISH
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
1/2" REVEAL TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
FIXTURE MANUF. TO PROVIDE LEVELERS
AutoCAD SHX Text
BASE OF PHONE DISPLAY TO RECEIVE FINISH
AutoCAD SHX Text
MT-1
AutoCAD SHX Text
DISPLAY SIGNAGE BY CLIENT
AutoCAD SHX Text
MW-2.0
AutoCAD SHX Text
5
AutoCAD SHX Text
RICHELIEU CAM LOCK #BP140101140
AutoCAD SHX Text
SIDE OF PHONE DISPLAY TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
SIDE OF PHONE DISPLAY TO RECEIVE FINISH
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
1/2" REVEAL TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
FIXTURE MANUF. TO PROVIDE LEVELERS
AutoCAD SHX Text
BASE OF PHONE DISPLAY TO RECEIVE FINISH
AutoCAD SHX Text
MT-1
AutoCAD SHX Text
DISPLAY SIGNAGE BY CLIENT
AutoCAD SHX Text
MILLWORK COUNTER & SIDE TO RECEIVE FINISH C/W MITRED EDGES & 1/2" PLYWOOD BACKING ON HOLLOW METAL TUBE SUPPORT ALL AROUND. PROVIDE BLOCKING AS REQUIRED.
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
PROVIDE OPENINGS FOR ACCESS TO CABLE AND POWER MANAGEMENT. GC TO COORDINATE WITH ELEC. CONSULTANT ON CABLE ACCESS REQUIREMENTS.
AutoCAD SHX Text
CABINET SHELVING AS REQUIRED TO RECEIVE FINISH
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
FIXTURE MANUF. TO PROVIDE LEVELERS
AutoCAD SHX Text
1/2" REVEAL TO RECEIVE FINISH
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
BASE C/W BLOCKING AS REQUIRED TO RECEIVE FINISH
AutoCAD SHX Text
MT-1
AutoCAD SHX Text
CABINET DOORS C/W CONCEALED TOUCH LATCH HARDWARE TO RECEIVE FINISH. HARDWARE TO BE PROVIDED BY MILLWORKER
AutoCAD SHX Text
DISPLAY SIGNAGE BY CLIENT
AutoCAD SHX Text
MILLWORK COUNTER & SIDE TO RECEIVE FINISH C/W MITRED EDGES & 1/2" PLYWOOD BACKING ON HOLLOW METAL TUBE SUPPORT ALL AROUND. PROVIDE BLOCKING AS REQUIRED.
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
PROVIDE OPENINGS FOR ACCESS TO CABLE AND POWER MANAGEMENT. GC TO COORDINATE WITH ELEC. CONSULTANT ON CABLE ACCESS REQUIREMENTS.
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
DOTTED LINE DENOTES STRUCTURAL SUPPORT & PROVISION FOR CABLE CHASE

SCALE:

3

MW-3.0

[M-3] LARGE DISPLAY TABLE - FRONT ELEVATION

1 1/2" = 1'-0"

KB03APR2017ISSUED FOR TENDER-R102

AW28FEB2017ISSUED FOR TENDER01

387 Richmond Street East

Toronto Canada M5A 1P6

www.sld.com

t 416.367.1999

f 416.367.5451

DRAWING NUMBER:

DOCKET:

SHEET SIZE:

DATE:

SCALE:

DRAWN BY:

CHECKED BY:

SL16790

ARCH D

DRAWING NAME:

PROJECT:

CLIENT:

CONSULTANT

GLENTEL

TBOOTH WIRELESS

SCARBOROUGH TOWN CENTRE

UNIT #758

300 BOROUGH DR

SCARBOROUGH,ON

M1P 4P5

ISSUES AND REVISIONS ( ): BY:DATE:

1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS

ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX

DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN

WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI

LACROIX.

2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT

ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING

WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE

CONTRACTOR'S EXPENSE.

3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S

DRAINGS IN THE CONTRACT.

4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.

5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE

DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.

6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN

CONFORMITY WITH THE BUILDING CODES IN FORCE.

7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE

CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE

TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL

EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.

GENERAL NOTES:

28-02-2017

as noted bw

aw

MILLWORK DETAILS

[M-3]

LARGE DISPLAY TABLE

ISSUED FOR

TENDER

DRAWINGS NOT FOR

CONSTRUCTION

MW-3.0

SCALE:

2

MW-3.0

[M-3] LARGE DISPLAY TABLE - SIDE ELEVATION

1 1/2" = 1'-0"

SCALE:

1

MW-3.0

[M-3] LARGE DISPLAY TABLE - PLAN

1 1/2" = 1'-0"

SCALE:

5

MW-3.0

[M-3] LARGE DISPLAY TABLE - SECTION PLAN

1 1/2" = 1'-0" SCALE:

4

MW-3.0

[M-3] LARGE DISPLAY TABLE - SECTION ELEVATION

1 1/2" = 1'-0"

AutoCAD SHX Text
MW-3.0
AutoCAD SHX Text
3
AutoCAD SHX Text
MW-3.0
AutoCAD SHX Text
2
AutoCAD SHX Text
MW-3.0
AutoCAD SHX Text
4
AutoCAD SHX Text
12" WIDE SLOTS C/W BLACK BRUSH SEAL
AutoCAD SHX Text
DOTTED LINE DENOTES RAW METAL STRIP UNDER PLASTIC LAMINATE
AutoCAD SHX Text
18" THK. EARTH MAGNETS WITHIN REMOVABLE LABELS
AutoCAD SHX Text
TOP OF PHONE DISPLAY TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
DISPLAY SIGNAGE BY CLIENT
AutoCAD SHX Text
SIDE OF PHONE DISPLAY TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
SIDE OF PHONE DISPLAY TO RECEIVE FINISH
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
1/2" REVEAL TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
FIXTURE MANUF. TO PROVIDE LEVELERS
AutoCAD SHX Text
BASE OF PHONE DISPLAY TO RECEIVE FINISH
AutoCAD SHX Text
MT-1
AutoCAD SHX Text
DISPLAY SIGNAGE BY CLIENT
AutoCAD SHX Text
SIDE OF PHONE DISPLAY TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
CABINET DOORS OF PHONE DISPLAY TO RECEIVE FINISH
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
1/2" REVEAL TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
FIXTURE MANUF. TO PROVIDE LEVELERS
AutoCAD SHX Text
BASE OF PHONE DISPLAY TO RECEIVE FINISH
AutoCAD SHX Text
MT-1
AutoCAD SHX Text
DISPLAY SIGNAGE BY CLIENT
AutoCAD SHX Text
MW-3.0
AutoCAD SHX Text
5
AutoCAD SHX Text
RICHELIEU CAM LOCK #BP140101140
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
MILLWORK COUNTER & SIDE TO RECEIVE FINISH C/W MITRED EDGES & 1/2" PLYWOOD BACKING ON HOLLOW METAL TUBE SUPPORT ALL AROUND. PROVIDE BLOCKING AS REQUIRED.
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
PROVIDE OPENINGS FOR ACCESS TO CABLE AND POWER MANAGEMENT. GC TO COORDINATE WITH ELEC. CONSULTANT ON CABLE ACCESS REQUIREMENTS.
AutoCAD SHX Text
DOTTED LINE DENOTES STRUCTURAL SUPPORT & PROVISION FOR CABLE CHASE
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
MILLWORK COUNTER & SIDE TO RECEIVE FINISH C/W MITRED EDGES & 1/2" PLYWOOD BACKING ON HOLLOW METAL TUBE SUPPORT ALL AROUND. PROVIDE BLOCKING AS REQUIRED.
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
PROVIDE OPENINGS FOR ACCESS TO CABLE AND POWER MANAGEMENT. GC TO COORDINATE WITH ELEC. CONSULTANT ON CABLE ACCESS REQUIREMENTS.
AutoCAD SHX Text
CABINET SHELVING AS REQUIRED TO RECEIVE FINISH
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
FIXTURE MANUF. TO PROVIDE LEVELERS
AutoCAD SHX Text
1/2" REVEAL TO RECEIVE FINISH
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
BASE C/W BLOCKING AS REQUIRED TO RECEIVE FINISH
AutoCAD SHX Text
MT-1
AutoCAD SHX Text
DISPLAY SIGNAGE BY CLIENT
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
CABINET DOORS TO BE

KB03APR2017ISSUED FOR TENDER-R102

AW28FEB2017ISSUED FOR TENDER01

387 Richmond Street East

Toronto Canada M5A 1P6

www.sld.com

t 416.367.1999

f 416.367.5451

DRAWING NUMBER:

DOCKET:

SHEET SIZE:

DATE:

SCALE:

DRAWN BY:

CHECKED BY:

SL16790

ARCH D

DRAWING NAME:

PROJECT:

CLIENT:

CONSULTANT

GLENTEL

TBOOTH WIRELESS

SCARBOROUGH TOWN CENTRE

UNIT #758

300 BOROUGH DR

SCARBOROUGH,ON

M1P 4P5

ISSUES AND REVISIONS ( ): BY:DATE:

1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS

ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX

DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN

WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI

LACROIX.

2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT

ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING

WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE

CONTRACTOR'S EXPENSE.

3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S

DRAINGS IN THE CONTRACT.

4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.

5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE

DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.

6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN

CONFORMITY WITH THE BUILDING CODES IN FORCE.

7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE

CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE

TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL

EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.

GENERAL NOTES:

28-02-2017

as noted bw

aw

MILLWORK DETAILS

[M-4]

CASH TABLE

ISSUED FOR

TENDER

DRAWINGS NOT FOR

CONSTRUCTION

MW-4.0SCALE:

1

MW-4.0

[M-4] CASH TABLE - PLAN

1 1/2" = 1'-0"

SCALE:

2

MW-4.0

[M-4] CASH TABLE - FRONT ELEVATION

1 1/2" = 1'-0"

SCALE:

3

MW-4.0

[M-4] CASH TABLE - SIDE ELEVATION

1 1/2" = 1'-0"

SCALE:

4

MW-4.0

[M-4] CASH TABLE - SIDE ELEVATION

1 1/2" = 1'-0"

SCALE:

5

MW-4.0

[M-4] CASH TABLE - SECTION ELEVATION

1 1/2" = 1'-0"

SCALE:

6

MW-4.0

[M-4] CASH TABLE - TABLE LEG DETAIL

1 1/2" = 1'-0"

AutoCAD SHX Text
TABLE TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
DOTTED LINES DENOTE BRACING AT U/S OF TABLE FOR ADDITIONAL SUPPORT AS REQUIRED. ALL EXPOSED SURFACES TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
ACRYLIC PANELS TO RECEIVE FINISH FIXED TO THE SURFACE IN A 14" DEEP SLOT
AutoCAD SHX Text
AC-1
AutoCAD SHX Text
PROVIDE 2" DIA GROMMET FOR CABLE FEED. CABLE TO FEED THROUGH METAL TROUGH BELOW AS INDICATED WITH DOTTED LINES. MILLWORKER TO PROVIDE HARDWARE.
AutoCAD SHX Text
DOTTED LINES DENOTE METAL TROUGH BELOW FOR CABLE FEED
AutoCAD SHX Text
TABLE TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
MW-4.0
AutoCAD SHX Text
3
AutoCAD SHX Text
MW-4.0
AutoCAD SHX Text
2
AutoCAD SHX Text
MW-4.0
AutoCAD SHX Text
5
AutoCAD SHX Text
MW-4.0
AutoCAD SHX Text
4
AutoCAD SHX Text
BARRIER FREE CLEARANCE
AutoCAD SHX Text
CASH BOX
AutoCAD SHX Text
TABLE TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
ACRYLIC PANELS TO RECEIVE FINISH
AutoCAD SHX Text
AC-1
AutoCAD SHX Text
TABLE LEG TO MATCH FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
CABINET DOOR TO RECEIVE FINISH
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
METAL TROUGH FOR CABLE CHASE
AutoCAD SHX Text
BASE TO RECEIVE FINISH
AutoCAD SHX Text
MT-1
AutoCAD SHX Text
FIXTURE MANUF. TO PROVIDE LEVELERS
AutoCAD SHX Text
MW4.0
AutoCAD SHX Text
6
AutoCAD SHX Text
TABLE TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
ACRYLIC PANELS TO RECEIVE FINISH
AutoCAD SHX Text
AC-1
AutoCAD SHX Text
TABLE LEG TO MATCH FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
FIXTURE MANUF. TO PROVIDE LEVELERS
AutoCAD SHX Text
BASE TO RECEIVE FINISH
AutoCAD SHX Text
MT-1
AutoCAD SHX Text
TABLE TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
ACRYLIC PANELS TO RECEIVE FINISH
AutoCAD SHX Text
AC-1
AutoCAD SHX Text
TABLE LEG TO MATCH FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
FIXTURE MANUF. TO PROVIDE LEVELERS
AutoCAD SHX Text
BASE TO RECEIVE FINISH
AutoCAD SHX Text
MT-1
AutoCAD SHX Text
CASH BOX
AutoCAD SHX Text
MILLWORK COUNTER & SIDE TO RECEIVE FINISH C/W MITRED EDGES & 1/2" PLYWOOD BACKING ON BLOCKING ALL AROUND AS REQUIRED.
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
CONCEALED CASH DRAWER C/W DEADBOLT LOCKING HARDWARE. DRAWER FRONT TO RECEIVEFINISH FINISH CASH DRAWER SPECS TBD
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
CABINET DOORS C/W CONCEALED TOUCH LATCH HARDWARE TO RECEIVE FINISH. HARDWARE TO BE PROVIDED BY MILLWORKER
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
PULL-OUT MILLWORK SHELF FOR PRINTER. ALL EXPOSED SURFACES TO BE FINISHED
AutoCAD SHX Text
3/4" THK ADJUSTABLE SHELVING TO RECEIVE FINISH
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
BASE C/W BLOCKING AS REQUIRED TO RECEIVE FINISH
AutoCAD SHX Text
MT-1
AutoCAD SHX Text
FIXTURE MANUF. TO PROVIDE LEVELERS
AutoCAD SHX Text
DOTTED LINES DENOTE 1/2" ACRYLIC DIVIDER PANELS FASTENED W/ EPOXY GLUE MOUTNED TO MILLWORK BEYOND (SEE ELEVATIONS). PANELS TO RECEIVE FINISH
AutoCAD SHX Text
AC-1
AutoCAD SHX Text
PROVIDE CAVITY FOR CABLE MANAGEMENT
AutoCAD SHX Text
3" TOP DIA OF LEG
AutoCAD SHX Text
2-1/4" BOTTOM DIA OF LEG
AutoCAD SHX Text
NOTE: GRID = 1" x 1"

KB03APR2017ISSUED FOR TENDER-R102

AW28FEB2017ISSUED FOR TENDER01

387 Richmond Street East

Toronto Canada M5A 1P6

www.sld.com

t 416.367.1999

f 416.367.5451

DRAWING NUMBER:

DOCKET:

SHEET SIZE:

DATE:

SCALE:

DRAWN BY:

CHECKED BY:

SL16790

ARCH D

DRAWING NAME:

PROJECT:

CLIENT:

CONSULTANT

GLENTEL

TBOOTH WIRELESS

SCARBOROUGH TOWN CENTRE

UNIT #758

300 BOROUGH DR

SCARBOROUGH,ON

M1P 4P5

ISSUES AND REVISIONS ( ): BY:DATE:

1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS

ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX

DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN

WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI

LACROIX.

2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT

ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING

WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE

CONTRACTOR'S EXPENSE.

3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S

DRAINGS IN THE CONTRACT.

4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.

5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE

DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.

6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN

CONFORMITY WITH THE BUILDING CODES IN FORCE.

7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE

CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE

TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL

EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.

GENERAL NOTES:

28-02-2017

as noted bw

aw

MILLWORK DETAILS

[M-5]

ACCESSORIES DISPLAY

ISSUED FOR

TENDER

DRAWINGS NOT FOR

CONSTRUCTION

MW-5.0SCALE:

2

MW-5.0

[M-5] ACCESSORIES DISPLAY - FRONT ELEVATION

1 1/2" = 1'-0" SCALE:

3

MW-5.0

[M-5] ACCESSORIES DISPLAY - SIDE ELEVATION

1 1/2" = 1'-0"

SCALE:

1

MW-5.0

[M-5] ACCESSORIES DISPLAY - PLAN

1 1/2" = 1'-0"

SCALE:

4

MW-5.0

[M-5] ACCESSORIES DISPLAY - SECTION ELEVATION

1 1/2" = 1'-0"

AutoCAD SHX Text
BACKLIT LED GRAPHIC PANEL BY:MCRAE IMAGING MCRAE IMAGING T:905.569.1605 LIGHTEX FRAME LUX BACKLIT 75mm SIZE: 3'-10-1/2" X 1'-0"
AutoCAD SHX Text
SLAT WALL W/ SLATS PLACED 2" O.C.
AutoCAD SHX Text
SLAT WALL FRAME TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
FIXED SHELF TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
CABINET FRAME TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
CABINET DOORS TO RECEIVE FINISH
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
BASE TO RECEIVE FINISH
AutoCAD SHX Text
MT-1
AutoCAD SHX Text
MW-5.0
AutoCAD SHX Text
3
AutoCAD SHX Text
RICHELIEU CAM LOCK #BP140101140
AutoCAD SHX Text
MW-5.0
AutoCAD SHX Text
3
AutoCAD SHX Text
MW-5.0
AutoCAD SHX Text
2
AutoCAD SHX Text
FRAME TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
SLAT WALL FRAME TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
DIRECTION OF WOOD GRAIN
AutoCAD SHX Text
BACKLIT LED GRAPHIC PANEL BY:MCRAEL IMAGING MCRAEL IMAGING T:905.569.1605 LIGHTEX FRAME LUX BACKLIT 75mm SIZE: 3'-10-1/2" X 1'-0"
AutoCAD SHX Text
SLAT WALL W/ SLATS PLACED 2" O.C.
AutoCAD SHX Text
FIXED SHELF C/W BLOCKING & FASTENING SYSTEM AS REQUIRED. ROUTER CUT CHANNELS TO ACCOMODATE LED STRIP LIGHT FIXTURES. SHELF TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
CABINET DOORS C/W CONCEALED TOUCH LATCH HARDWARE TO RECEIVE FINISH. HARDWARE TO BE PROVIDED BY MILLWORKER
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
PROVIDE ADEQUATE CABLE CHASE AS REQUIRED FOR WIRING & CABLE MANAGEMENT. GC TO COORDINATE.
AutoCAD SHX Text
BASE TO RECEIVE FINISH
AutoCAD SHX Text
MT-1
AutoCAD SHX Text
1 METER ALUMINUM EXTRUSION WITH WINGS AND FROSTED DIFFUSER 0.5" DEEP EX-KL-3FR-1M BY: ECOLOCITY LED (OR EQUAL)
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
1 METER ALUMINUM EXTRUSION WITH WINGS AND FROSTED DIFFUSER 0.5" DEEP EX-KL-3FR-1M BY: ECOLOCITY LED (OR EQUAL)
AutoCAD SHX Text
ELECTRICAL OUTLET COL. WHITE

KB03APR2017ISSUED FOR TENDER-R102

AW28FEB2017ISSUED FOR TENDER01

387 Richmond Street East

Toronto Canada M5A 1P6

www.sld.com

t 416.367.1999

f 416.367.5451

DRAWING NUMBER:

DOCKET:

SHEET SIZE:

DATE:

SCALE:

DRAWN BY:

CHECKED BY:

SL16790

ARCH D

DRAWING NAME:

PROJECT:

CLIENT:

CONSULTANT

GLENTEL

TBOOTH WIRELESS

SCARBOROUGH TOWN CENTRE

UNIT #758

300 BOROUGH DR

SCARBOROUGH,ON

M1P 4P5

ISSUES AND REVISIONS ( ): BY:DATE:

1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS

ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX

DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN

WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI

LACROIX.

2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT

ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING

WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE

CONTRACTOR'S EXPENSE.

3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S

DRAINGS IN THE CONTRACT.

4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.

5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE

DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.

6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN

CONFORMITY WITH THE BUILDING CODES IN FORCE.

7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE

CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE

TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL

EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.

GENERAL NOTES:

28-02-2017

as noted bw

aw

MILLWORK DETAILS

[M-6]

BANQUETTE C/W

BACKLIT GRAPHICS

ISSUED FOR

TENDER

DRAWINGS NOT FOR

CONSTRUCTION

MW-6.0SCALE:

1

MW-6.0

[M-6] BANQUETTE C/W BACKLIT GRAPHIC - FRONT ELEVATION

1" = 1'-0" SCALE:

2

MW-6.0

[M-6] BANQUETTE C/W BACKLIT GRAPHIC - SECTION ELEVATION

1" = 1'-0"

AutoCAD SHX Text
BACKLIT LED GRAPHIC PANEL BY:MCRAE IMAGING MCRAE IMAGING T:905.569.1605 LIGHTEX FRAME LUX BACKLIT 75mm SIZE: 6'-3" X 4'-0"
AutoCAD SHX Text
SEAT & SEAT BACK TO RECEIVE FINISH
AutoCAD SHX Text
FB-1
AutoCAD SHX Text
GRAPHICS PANEL BY CLIENT
AutoCAD SHX Text
MW-6.0
AutoCAD SHX Text
2
AutoCAD SHX Text
INDICATES SEAMS OF VENEER
AutoCAD SHX Text
WD-1
AutoCAD SHX Text
WOOD VENEER SHEET SIZE (3X11)
AutoCAD SHX Text
DIRECTION OF WOOD GRAIN
AutoCAD SHX Text
BACKLIT LED GRAPHIC PANEL BY:MCRAE IMAGING MCRAE IMAGING T:905.569.1605 LIGHTEX FRAME LUX BACKLIT 75mm SIZE: 6'-3" X 4'-0"
AutoCAD SHX Text
4 1/2" THICK FOAM SEAT, FORMED AS SHOWN, WITH 8 OZ. POLY FIBER, C/W PLYWOOD FRAME CONST. & BLOCKING AS REQUIRED. SEAT TO RECEIVE FINISH
AutoCAD SHX Text
FB-1
AutoCAD SHX Text
MEDIUM DENSITY FOAM BACK W/ 4 OZ. POLY FIBER. SEAT BACK TO RECEIVE FINISH CLEATED TO BACK WALL
AutoCAD SHX Text
FB-1
AutoCAD SHX Text
BANQUETTE SEAT FRAME C/W BLOCKING AS REQUIRED. FRAME TO RECEIVE FINISH ALL AROUND
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
FB-1

B

A

C

E

A

B

C

D

E

KB03APR2017ISSUED FOR TENDER-R102

AW28FEB2017ISSUED FOR TENDER01

387 Richmond Street East

Toronto Canada M5A 1P6

www.sld.com

t 416.367.1999

f 416.367.5451

DRAWING NUMBER:

DOCKET:

SHEET SIZE:

DATE:

SCALE:

DRAWN BY:

CHECKED BY:

SL16790

ARCH D

DRAWING NAME:

PROJECT:

CLIENT:

CONSULTANT

GLENTEL

TBOOTH WIRELESS

SCARBOROUGH TOWN CENTRE

UNIT #758

300 BOROUGH DR

SCARBOROUGH,ON

M1P 4P5

ISSUES AND REVISIONS ( ): BY:DATE:

1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS

ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX

DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN

WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI

LACROIX.

2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT

ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING

WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE

CONTRACTOR'S EXPENSE.

3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S

DRAINGS IN THE CONTRACT.

4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.

5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE

DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.

6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN

CONFORMITY WITH THE BUILDING CODES IN FORCE.

7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE

CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE

TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL

EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.

GENERAL NOTES:

28-02-2017

as noted bw

aw

MILLWORK DETAILS

[M-7]

CUSTOM OTTOMAN

ISSUED FOR

TENDER

DRAWINGS NOT FOR

CONSTRUCTION

MW-7.0

SCALE:

1

MW-7.0

[M-7] CUSTOM OTTOMAN - PLAN

1 1/2" = 1'-0" SCALE:

2

MW-7.0

[M-7] CUSTOM OTTOMAN - ELEVATION

1 1/2" = 1'-0"

SCALE:

3

MW-7.0

[M-7] CUSTOM OTTOMAN - SECTION ELEVATION

3" = 1'-0"

AutoCAD SHX Text
OTTOMAN SEAT TO BE 4-1/2" THK FOAM SEAT W/ 8 OZ. POLY FIBER, C/W PLYWOOD & BLOCKING CONSTRUCTION AS REQUIRED. SEAT TO RECEIVE FINISH
AutoCAD SHX Text
FB-2
AutoCAD SHX Text
MW-7.0
AutoCAD SHX Text
2
AutoCAD SHX Text
MW-7.0
AutoCAD SHX Text
3
AutoCAD SHX Text
LOCATION OF SEAMS
AutoCAD SHX Text
OTTOMAN SEAT TO BE 4-1/2" THK FOAM SEAT W/ 8 OZ. POLY FIBER, C/W PLYWOOD & BLOCKING CONSTRUCTION AS REQUIRED. SEAT TO RECEIVE FINISH
AutoCAD SHX Text
FB-2
AutoCAD SHX Text
BASE TO RECEIVE FINISH
AutoCAD SHX Text
FB-2
AutoCAD SHX Text
MT-1
AutoCAD SHX Text
SEAT TO RECEIVE HIGH DENSITY FOAM
AutoCAD SHX Text
[M-7] CUSTOM BENCH
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DESCRIPTION:
AutoCAD SHX Text
TO MATCH FABRIC FOR FB-2
AutoCAD SHX Text
FIXTURE MANUFACTURER TO PROVIDE LEVELERS ON ALL BENCH LEGS
AutoCAD SHX Text
FIXTURE MANUFACTURER TO PROVIDE ADEQUATE METAL BRACING TO MAKE CUSTOM BENCH STRUCTURALLY SOUND.
AutoCAD SHX Text
FIXTURE MANUFACTURER TO PROVIDE ADEQUATE WOOD BRACING TO SUPPORT LIVE LOADS

KB03APR2017ISSUED FOR TENDER-R102

AW28FEB2017ISSUED FOR TENDER01

387 Richmond Street East

Toronto Canada M5A 1P6

www.sld.com

t 416.367.1999

f 416.367.5451

DRAWING NUMBER:

DOCKET:

SHEET SIZE:

DATE:

SCALE:

DRAWN BY:

CHECKED BY:

SL16790

ARCH D

DRAWING NAME:

PROJECT:

CLIENT:

CONSULTANT

GLENTEL

TBOOTH WIRELESS

SCARBOROUGH TOWN CENTRE

UNIT #758

300 BOROUGH DR

SCARBOROUGH,ON

M1P 4P5

ISSUES AND REVISIONS ( ): BY:DATE:

1. THE CONTENTS OF THIS DRAWING SET AND ALL SUPPLEMENTARY DESIGN DOCUMENTS

ARE ISSUED UNDER SEPARATE COVERS ARE THE PROPERTY OF SHIKATANI LACROIX

DESIGN INC, 2016 ALL RIGHTS RESERVED. NOT TO BE USED OR REPRODUCED IN

WHOLE OR IN PART WIHOUT THE EXPRESS WRITTEN PERMISSION OF SHIKATANI

LACROIX.

2. CONTRACTOR MUST VERIFY ALL ON-SITE DIMENSIONS AND CONDITIONS AND REPORT

ANY DISCREPANCIES TO SHIKATANI LACROIX DESIGN INC. PRIOR TO COMMENCING

WORK. UNFORSEEN EXTRAS RESULTING FROM A FAILURE TO DO SO WILL BE AT THE

CONTRACTOR'S EXPENSE.

3. DESIGN DRAWINGS ARE TO BE READ IN CONJUCTION WITH ALL OTHER CONSULTANT'S

DRAINGS IN THE CONTRACT.

4. DO NOT SCALE DRAWINGS. WORK TO DIMENSIONS ONLY.

5. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL FIXTURES AND SUBMIT THESE

DRAWINGS TO SHIKATANI LACROIX FOR APPROVAL.

6. ALL CONSTRUCTION TO BE ACCORDING TO BEST COMMON PRACTICES AND IN

CONFORMITY WITH THE BUILDING CODES IN FORCE.

7. THE OWNER WILL EXPECT ALL CLARIFICATIONS AND DISCREPANCIES WITHIN THE

CONTRACT DOCUMENTS TO BE ANSWERED THROUGH RFIs DURING THE

TENDER/PRE-CONTRACT AWARD PERIOD. IF NO RFIs ARE RECEIVED, THE OWNER WILL

EXPECT THE HIGHER QUANTITY AND/OR CONTRACTOR AT NO EXTRA COST.

GENERAL NOTES:

28-02-2017

as noted bw

aw

MILLWORK DETAILS

[M-8]

CARRIERS DISPLAY

ISSUED FOR

TENDER

DRAWINGS NOT FOR

CONSTRUCTION

MW-8.0SCALE:

2

MW-8.0

[M-8] CARRIERS DISPLAY - ELEVATION

1 1/2" = 1'-0" SCALE:

4

MW-8.0

[M-8] CARRIERS DISPLAY - SECTION ELEVATION

1 1/2" = 1'-0"SCALE:

3

MW-8.0

[M-8] CARRIERS DISPLAY - SECTION ELEVATION

1 1/2" = 1'-0"

SCALE:

1

MW-8.0

[M-8] CARRIERS DISPLAY - PLAN

1 1/2" = 1'-0"

AutoCAD SHX Text
TV BY CLIENT
AutoCAD SHX Text
TV WALL PANEL TO RECEIVE FINISH
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
SHELVING UNIT TO RECEIVE FINISH
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
MW-8.0
AutoCAD SHX Text
4
AutoCAD SHX Text
MW-8.0
AutoCAD SHX Text
3
AutoCAD SHX Text
MW-8.0
AutoCAD SHX Text
2
AutoCAD SHX Text
TV WALL PANEL TO RECEIVE FINISH
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
SHELVING UNIT TO RECEIVE FINISH
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
DIRECTION OF WOOD GRAIN
AutoCAD SHX Text
LOWER PANEL TO RECEIVE FINISH
AutoCAD SHX Text
PL-2
AutoCAD SHX Text
PANEL TO BE FINISHED
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
TV BY CLIENT
AutoCAD SHX Text
SHELVING UNIT TO RECEIVE FINISH
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
BACK PANEL TO BE FINISHED
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
TV BY CLIENT
AutoCAD SHX Text
SHELVING UNIT TO RECEIVE FINISH
AutoCAD SHX Text
PL-1
AutoCAD SHX Text
LOWER PANEL TO RECEIVE FINISH
AutoCAD SHX Text
PL-2