tambour door systems for creative interior designs ?· tambour door systems for creative interior...

Download TAMBOUR DOOR SYSTEMS FOR CREATIVE INTERIOR DESIGNS ?· TAMBOUR DOOR SYSTEMS FOR CREATIVE INTERIOR DESIGNS.…

Post on 30-Jul-2018

212 views

Category:

Documents

0 download

Embed Size (px)

TRANSCRIPT

  • TAMBOUR DOOR SYSTEMS FOR CREATIVE INTERIOR DESIGNS

    C3-VERTICAL APPLICATIONS

    such as: Kitchens Closet systems Ready-to-assemble and residential furniture Office and contract furniture Secure record storage for the healthcare industry Retail store fixtures

    T ambour Door Systems offer unlimited potential for the creative designer in applications

    System features: Genuine metal extrusions on a

    polymer base for a true metallicfinish

    soft hinge connects individualslats

    Color-coordinated systemcomponents

    Endless design possibilitiesvertical applications

    Available in aluminum or stainlesssteel finishes

    Metallic Line for trendy metallic tambour door solutions

    500 Indeneer Drive, Suite 4 Kernersville, NC 27284 USA

    1.800.668.7080 336.992.2464 faxwww.efi-us.com

  • VErtiCal appliCationsC3 CountErbalanCE sYstEm

    1 C3 Tambour Mechanism and Extensiona. Available in 6 sizes to fit standard cabinet widthsb. Extensionsaccommodatevirtuallyallcabinet

    widths

    a.

    2 Tambour Doorsa. ChoiceofMetallicLinealuminumandstainless

    steel finishes b. Optionalmid-gripsection

    3 Handlesa. Availableinlockingandnon-lockingvariationsb. Optionsworkwiththree-orfour-sidedcabinets

    2

    2

    3

    4

    3

    1

    2

    4

    Cross-sectional view of C3 counterbalance system

    min. 29

    0

    An internal cabinet depth of at least 290 mm is required for installation.

    An internal cabinet depth of at least 290 mm is required for installation.

    C

    MetallicLine

    Aluminum

    StainlessSteel

  • mm

    )

    mm

    )

    /4(

    400

    (100

    0

    5/8

    (60

    0m

    m)

    mm

    ) m

    m)

    1/2

    (80

    0 m

    m)

    /8 (

    1400

    1/8

    15 1/4

    (12

    00

    12 9 47

    55

    Recommended Cabinet Sizes for Vertical Applications with C3

    Cabinet Height

    821/2"(2100mm)74/4"

    68/4"(1750mm) (1900mm)

    55"(1400mm)

    411/4"(1050mm)

    271/2"(700mm) 25/8"(600mm)

    11/2"(50mm)

    Cabinet Width (mm)

    VErtiCal appliCationsC3 CountErbalanCE sYstEm

    21

    System Description

    TheCsystemfeaturesahigh-quality,

    spring-loadedmechanismthatprovides

    optimalcounterweightforsuperior,light-

    weightoperation.

    Can be adjusted to fit cabinets with dif-

    ferentwallthicknesses

    Requiresminimalamountofcabinet

    space

    Mid-gripsectionmakeshandling

    easierinlargercabinets

    Art. see right

    1 Mechanism

    Cabinet CabinetInside(mm)

    550-584

    7-758

    750-784

    876-910

    1029-106

    1181-1215

    Outside

    24"(600mm)

    0"

    1"(800mm)

    6"

    42"

    48"

    2 Extension

    Extensionprovidesfullcoveragefrom

    215/8-471/16(550-1215mm)

    Art. 455069

    C

    Imagine the Possibilities

    tspiveyStamp

  • Feed component allows smooth tambour transition from the track to the C3 counterbalance system.

    Track Cover End Cap Feed Mid Grip HandleCover Profile

    VErtiCal appliCationsC3 CountErbalanCE sYstEmFramE traCK

    rti appli ations

    3 mm [#4] screws should be used to attach the surface mounted track.

    Track Frame

    Art. 780654

    19

    28.65

    1618/19

    360

    19

    15

    52

    8

    45

    9

    19

    27

    20

    8

    Cross sECtions

    C

    Tambourisacomplexprogramwithmany

    optionsfordesignandfunction.Contact

    us for any support you need as you define

    yourprogram.

    Grip Handle Glider Standard Grip Handle

    ALU: Art. 255050SS: Art. 255051

    Left : Art. 455061Right: Art. 455060

    Art. 255052 Art. 255053 Art. 455056 Art. 455079 Art. 255055 Art. 255080 Art. 455081

    ALU: Art. 255050SS: Art. 255051

    Art. 255052 ALU: Art. 255048SS: Art. 255049

    Art. 255055

    Art. 455079

    When Placing Order order we will need

    Internal width, height and depth of cabinetType of system (C3 or C6) Finish of tambour (aluminum or stainless steel)If it is a 3 or 4 sided cabinet Locking or none locking handle

    tspiveyStamp

  • Assembly Instructions

    System Components

    1 C3 Counter Balance Mechanism Spring-loaded roller Guide roller End brackets

    2 Tambour Carpet2 Tambour Carpet

    3 Handle Profi le

    Mid Grip Profi le with Adapter Profi le(optional)

    5 Running Track

    6 Cover Profi le

    7 Accessories End caps for running track Handle profi le gliders Grip handle stops Sealing profi le

    2

    1

    34

    5

    6

    1 C3 Counter Balance Mechanism1

    2

    3 Handle Profile3

    Mid Grip Profile with Adapter Profile4

    5 Running Track5

    6 Cover Profile6

    7 Accessories7

    min. 29

    0

    Fig. 1

    An internal cabinet depth of at least 290 mm is required for installation.

    Required Number of Tambour Slats Per Cabinet

    Tambour Slat Cut Length

    Recommended Limits for Cabinet Size

    Tambour Carpet Assembly

    # Slats = (internal height / slat width*) + starter slats

    * Slat width: Metallic Line = 20 mm

    Starter slats = (3) plastic slats

    Cut slat length = internal width 11 mm

    Slide individual tambour slats together toconstruct the tambour carpet.

    Place tambour carpet face down on fl at, clean surface.

    Apply tambour tape to back of carpet.Distance from cut edges of carpet to the tape should be at least 50 mm.

    Pieces of Tape Slat Length (mm) 1 < 300 2 Between 300 and 700 3 > 700

    Pieces of Tape Slat Length (mm) 1 < 300 2 Between 300 and 700 3 > 700

    2100

    1700

    1450

    1050

    Inte

    rnal

    Hei

    ght (

    mm

    )

    400 600 800 1000 1200Internal Width (mm)

    Areas of Use

    Tambour carpet orientation is important. Starter slats are at the top of the carpet. The open tambour door connection should be at the top of the carpet. (Fig. 4)

    Fig. 2

    Fig. 4

    Fig. 3Fig. 3

    Acceptable cabinet size

    Limit of application

    Limit for Metallic Line

    Starter Slats

    Tape

    C3 Counter Balance

    1

    tspiveyStamp

  • After applying the tambour tape, slide the spring-loaded roller with the connector rings over the top tambour profi le.

    Carpet orientation should be as shown in Fig. 5.

    Caution!Do not pre-load the spring-loaded roller mechanism before it is installed into the cabinet.

    Line up the spring-loaded roller and position it until the distance between the right edge of the tambour carpet and the right edge of the spring-loaded roller (marked with an R) is 9 mm. (Fig. 6)

    Secure tambour to each ring connector with a screw 3 x 13 mm.

    Roll the tambour carpet around the spring-loaded roller.

    Temporarily tape the rolled up carpet for installation.

    Lay the tambour on the table with the adhe-sive tape at the front.

    Push the brackets onto the guide roller and spring-loaded roller. (Fig. 7)

    The unit is ready for installation.

    Fig. 5

    Fig. 6

    Fig. 7

    2

    9 mm

    Attaching the C3 Counter Balance

    Internal Cabinet

    Width - 25 m

    m

    Cover Profi le Fabrication

    Cut the cover profi le to size. Cut length = internal cabinet width 25 mm.

    Fig. 8Fig. 8

  • Fig. 9

    21.5

    42Dowel/Screw 8 mm

    8

    Fitting the Running TrackFabrication of the lower running track de-pends on whether it is a three- or four-sided cabinet, and the height of the cabinet.

    Overall cabinet height

    Determine the cupboard style

    Countertop unit4-sided

    Wall mounted unit4-sided

    Countertop unit3-sided

    Cut to external height 1.5 mm

    Cut to external height 3 mm

    Cut to external height 1.5 mm

    Fabrication complete. Running track ready for assembly.

    Preparing for AssemblyPreparing the CabinetBoth sides of the cabinet are prepared as follows.

    Fig. 10

    Screw 2.5 mm

    * For cabinet heights < 1000 mm** For cabinet heights > 1000 mm** For cabinet heights > 1000 mm

    Mark the position of the guide roller and pre-drill a hole 8 mm in diameter. Fit the positioning dowel. (Fig. 9)

    Mark the position of the back fi xing hole. Pre-drill a hole 2.5 mm in diameter using the end bracket as a template. Make sure the end bracket as a template. Make sure the end bracket is pushed against the front the end bracket is pushed against the front dowel. (Fig. 10)

    A wood or metal cross member should be positioned underneath the front end of the positioned underneath the front end of the end brackets as an upper limit stop for the door (Fig. 10). Another solution is a shelf directly below the C3 system to hide the system. Clearance between the bottom of the rolled up carpet and the shelf must be 10 mm.

    110 mm*110 mm* 130 mm** 130 mm**

    There should be a minimum gap of 10 mm between the rolled up carpet and the top of the cabinet.

    Track FabricationDetermine the length of the running track using the following diagram.

    Installation

    Installing the Running TracksScrew the running tracks onto the cabinet.

    Install top and bottom end cap using pan head screws. (Fig. 11)

    Snap on frame cover as shown (Fig. 12 )

    3-Sided countertop unit (no bottom board) shown.

    Upper limit stop

    For reference only

    Gap on wall mounted unit should be13 mm from the top and bottom of the cabinet. (Fig. 10)

    (Fig. 11)

    (Fig. 12)

    (Fig. 10)Install valance cover with screws (Fig. 13 )

    (Fig. 13)

    (Fig. 13)

    (Fig. 12) 3

Recommended

View more >