tagvinduer uk
TRANSCRIPT
-
7/30/2019 Tagvinduer Uk
1/16
Catalogue of productsValid from 8.3.2007
Roofwindowsfull of sun
-
7/30/2019 Tagvinduer Uk
2/162 R O O F W I N D O W S F U L L O F S U N
Introduction of company
Manufacture of roof windows FENESTRA was started asearly as 1986. The manufacturing plant is located inhlavice (district Plze - south). About fifty workers dotheir best to ensure top quality and short delivery terms.The company FENESTRA sten okna, s.r.o. is currentlythe leading manufacturer of roof windows in the Czech
Republic.
The partner for foreign customers is the subsidiary, FENESTRAEXPORT, s.r.o. Surely, one of the most interesting references is 22pieces of roof windows delivered for the Czech Embassy in Nairobi,Kenya. Here, in Africa, the FENESTRA roof windows have beenresisting monsoon downpours and tropical rains.Anothercountries,when we can meet with FENESTRA roof windows are:
Denmark, Greece, Israel, Palestine, Jordan, Austria, Germany andSlovakia.
c u st o m e r c a r e c o n s u l t a n c y s e r v i c eFENESTRA roof windows are accompanied by a number of services
provided free of charge. We will be happy to show you the roof windows, and
recommend the best sizes and accessories. We will consult the most suitable
layout of windows either over a project, or right on the building site. We will
train workers of construction and assembling firms, and perform
demonstration assemblies. We will provide architects and designers with a
CD-ROM with electronic data for design programs.
Every year, hundreds interesting orders are implemented, such as the Czech
Embassy in Nairobi, Kenya (Africa, 22 pcs), terraced houses in Bratislava
(Slovakia, 64 pcs), Town Hall in esk Budjovice (90 pieces), suburban
village of Srnojedy (96 flats, 353 windows), a school for the disabled in Prno(190 pieces), polyfunctional building Marjnka (SKANSKA, 100 pieces),
elementary school Suick (METROSTAV, Prague, 199 pieces), school for
the deaf, Holekova (GEOSAN GROUP, Praha, 140 pieces), apartment
building Molkova (METROSTAV, Brno, 149 pcs), terraced houses in Vtn
(VCES, esk Krumlov, 100 pcs) and others.
-
7/30/2019 Tagvinduer Uk
3/16FENESTRA 3
ContentsIntroduction of company . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3
- line of dimensions
- labelling of FENESTRA windows
Advantages of FENESTRA roof windows . . . . . . . . . . . . . . . . . . . . pages 4-5
- THERMOS heat insulation set
Roof windows with a vent flap . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 6-7
- product line OPTIMAL (O)
- product line EXCELLENT (E)
- recommended product line THERMICAL (T)
- facade windows
- dormer window without thermal insulation (SV)
Another types of roof windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8
- spatial window of a garret type
Edging between the window and roofing . . . . . . . . . . . . . . . . . . . . . . page 9
- edging for shallow-profiled roofing (H)
- edging for deep-profiled roofing (T)
- edging for welted roofing (F)
- COMBI-edging
Accessories of FENESTRA roof windows . . . . . . . . . . . . . . . . . . . . . page 10
- interior accessories
- exterior accessories
- packets of accessories
Colour shades of Interior roller and Al blinds . . . . . . . . . . . . . . . . . page 11
Control elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 12
General principles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
Important things during installation . . . . . . . . . . . . . . . . . . . . . . . . . page 14
- observing of given distances
- levelling of roof cracks
- meeting of hydroisolation foil and placing of drain channel
- closing of roof covering to the high rib of edging
Special kinds of assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15
- curved roofing
- insulation over roof truss
- windows in the ridge
- lifting frame for small gradients
- snow stoppers
Dimensions of windows
55 66 78 86 94 114
160
140
118
98
78
66
506OK
EK
TK
606EF
TF
706EF
TF
806EF
TF
906EF
TF
507OK
EK
TK
607EF
TF
SV
707EF
TF
807EF
TF
907EF
TF
609EF
TF
709OK
EKTK
EF
TF
809EF
TF
909EF
TF
940OK
EK
TK
F40OK
618OK
EK
TK
718OK
EK
TK
EV
TV
818OK
EK
TK
EV
TV
F18OK
740OK
EK
TK
EV
TV
760OK
EK
TK
960OK
840OK
EK
TK
EV
TV
Windowcode
Windowheight
Windowwidth
The stated dimensions are outer frame dimensions (cm).
EK 718 CU/SP/W
Labelling of FENESTRA windows
Optional properties
CU - cooper flashingSP - lower lockW - white glazing
Window code
7 - width (78 cm)18 - height (118 cm)see the table of
window dimension
Product line and construction type
O -OPTIMAL product lineE -EXCELLENTproduct lineT -THERMICAL product line
K - swinging windowV - tilting-swinging windowF - facade windowM - spatial window of a garret type
Tilting-swinging windowSwinging window
-
7/30/2019 Tagvinduer Uk
4/16
Vent flap (E,T)
The vent flap ensures permanentreplacement of moist air inside theroom by fresh air from the outside(20 m3 per hour) with the windowclosed. The built-in filter removesdust and other dirt from the air.The
filter can be cleaned or replaced.This way of ventilation is convenientduring the so-called transition periodwhen the outer temperature does notdrop below 0 C.
SealingNo less important part of the energy-savingsystem is the two-stage combined sealingbetween the window frame and leafpreventing heat leakage out of the roomreliably.
3rd stage sealing
The third stage of sealing is fitted in the outerflashing. It presents another barrier to preventheat dissipation from the room, and at thesame time, it does not allow water mist andmoist air to penetrate under the windowflashing. This way, perfect anti-leakageprotection is ensured, even with very smallgradients of the roof structure.
Al flashing
Flashing of FENESTRA roof windows ismade of both-side painted aluminium sheet,which does not need any maintenance.Theuniversal dun colour ensures aestheticincorporation of windows into the roofing of allshades.
Embedding in the roofing plane
Harmonic embedding in the roofing plane hasbeen achieved by means of lowering theupper level of the window by 35 mm.Embedding of the window in the roofing hasalso improved the thermal insulationparameters.
Cu flashingWe can manufacture copper-sheet flashingon request.
Press-up lock
The upper lock with a modern design and apress-up function ensures comfortablecontrol, not risking unpleasant contact offinger joints with the upper part of the windowframe. For windows placed in higherpositions, we offer a number of controlelements (lower lock, control stick, cordcontrol, and electric remote control).
Central fitting
When you open the window leaf, ventilation is
very intensive.You can easily control theamount of air flowing into the room using thelocking positions of the central fitting. Thecentral fitting is made of corrosion-proof steel,which ensures flawless function all over thewindow life cycle, and eliminates damage ormaterial fatigue caused by motion of the moststressed window part.
Wood with white glazing
Windows of the WHITE finish with highresistant surface treatment are intendedespecially forrooms with high humidity (basic preservation+ 7 layers of versatile white glazing - 300 ).
Watertight and elegantEncased sheet window sheathing, the windowembedded in the roofing plane, and thecurved upper part of edging give theFENESTRA roof windows very elegant andmodern look. Guardings integrated in thelower part of the window make tight allspaces between the window leaf, frame andflashing, which protects the interior livingspace from blowing snow or water mist inside,even on the windward side, andwhen the roof gradient is small.
Insulation double glazing with "warm edge"The basic element is insulation doubleglazing (4-16-4 mm) with a soft coating layer,which ensures reflection of heat energy that
is normally lost back into the room.Thespacer bar between the panes, made of lowconductive material, creates so-called warmedge. Besides the improved value of heatpassage index (Uwindow = 1.1 W.m-2.K-1), it hasmajor influence on reduced moisturecondensate on the interior pane as well.
WarrantyWe provide up to 15-year warranty for theFENESTRA windows.Windows are certifiedby an accredited testing laboratory withpermanent supervision by an authorizedperson.
Price
Economic benefit is given by an excellentproportion of quality, utility properties, and theprice, which will pleasantly surprise you notonly at the moment of purchase, but for allthe useful life, as prices of accessories andspare parts are lower by a class.
Wood with clear top glazing
Wooden parts of the FENESTRAwindows are made of first class p ine.Basic preservation protects woodagainst blue-staining, moulds anddry-rot. Versatile top glazing develops
final protection from water and UVradiation impact (basic preservation +3 layers of glazing - 180 ).It is not necessary to paint thewindows after being assembled.
Thermo strips (E,T)
Original thermo strips create additionalspace for strengthening of heat insulationat spots where the lining is at an acuteangle with the roof gradient.Biggeramount of heat insulation eliminatesthermal bridges above and below the
window.
One-piece edging upper part
The unique manufacturing technologyat automatic forming centre enablesproduction of the upper part of edgingfrom one piece. This secures drain ofrainwater from the entire roof surface
above the window, as well asabsolute sureness of watertightness,even in winter, when snow oftenremains above the window, and thawsand freezes again repeatedly.
4 R O O F W I N D O W S F U L L O F S U N
Advantages of FENESTRA roof windows
Advantages
-
7/30/2019 Tagvinduer Uk
5/16
THERMOS heat insulation set
3rdstage sealing the insulation with 5 mmextruded polystyrene
Insulation double glazingwith "warm edge"
deep groove for insulationdouble glazing
wide wooden profile
2nd stage sealing
1ststage sealing
10,45 C
12,29 C
It was gauged for this conditions:outside temperature -15 C, inside temperature+21 C.This construction is only wone,which fulfils the Norm SN 730540.Forextra thermal-isolation conditions was appreciate on the STECHY 2007exhibition in Prag.
-14,7 . . . -11,4-11,4 . . . . -8,1-8,1 . . . . -4,8-4,8 . . . . -1,6-1,6. . . . . 1,71,7 . . . . . 5,05,0 . . . . . 8,38,3 . . . . 11,5
11,5 . . . . 14,814,8 . . . . 18,1
File of temperature CID glazing
range
insulation
frame
132
4
9
8
13
7
5
3
2
4
11
12
96
1
6
7
411
12
8
13
10
15
15
15
1 thermostrips 2 polyurethane sealing3 tiles suppor t 4 foil "collar" 5 drain channel 6 vapour-proof barrier7 under-roof fo il 8 thermal insulation9 lining
10 rafter
11 laths 12 counter- la ths 13 free space for aeration15 extruded polystyrene
For deep (profiled) roofing material
A roof window with the THERMOSheat insulation set has substantiallyimproved thermal-insulation properties.The entire window is lined with
extruded polystyrene of 30 mmthickness along the whole frameperimeter, presenting an unrivalledUframe = 0.5 W.m-2.K-1. Thanks to theinsulation, the indoor surfacetemperature of the window frameincreases by 5.5 C.
The polystyrene lining insulates all theframe of window over the roofingplane. A specially adapted edgingenables insulation of a roof window.
FENESTRA 5
Advantages
THERMOS heat insulation set
Diagram of FENESTRA roof w indow f i t t ingwith the THERMOS heat insulation set
The assembly of roof windows withTHERMOS heat insulation set Is veryeasy,it doesnt take more time,because all insulation pieces aretogether with edging from themanufacture.
Incision throught roof window of line THERMICALwith THERMOS heat insulation set.
The THERMICALs file of temperature with aplicationTHERMOS heat insulation set
Construction and location of anotherheat insulation sets do not makethermal-isolation conditions and surfacetemperatures better,because they do notisolate roof window up the roof.On thatpart the window is not protected againthe freezing.
-
7/30/2019 Tagvinduer Uk
6/166 R O O F W I N D O W S F U L L O F S U N
Roof windows with vent flap
Swinging window Tilting-swinging window
construction types
Technical specifications construction type
- swinging window (OK)
for roof gradients 15 to 85
- range of window leaf motion can be turned
by 145 to clean the outer surface
comfortably from the room
control by handle in the upper part of the roof
lower lock - optional (lower lock - optional)
flashing painted aluminium sheet
(copper flashing - optional) surface treatment versatile neutral glazing
(1x basic + 1 layer of neutra glazing)
wooden parts are made of neverending weld
(coloured diferences are possible)
vent flaps (14 m3 per hour)
1st stage of sealing between the frame and the
window leaf groove for the 2nd stage of
sealing (sealing - optional), 3rd stage of
sealing in the flashing
fixing bolt including
glazing double glazing with a warm edge U=1.1
W.m-2.K-1, acoustic insulation: 32 dB
thermal-insulation properties whole window
U=1.4 W.m-2.K-1
volume joint permeability iv:
0.24.10-4 m2.S-1.Pa-0.67
joint leakage rate mv = 0.0 l.h-1.m-1
warranty 5 years
O P T I M A L E X C E L L E N T
R
oofwindowswith
ventflap
OPTIMAL roof window withventilationNew product line with solid
properties and extra low price
Technical specifications construction types
- swinging window (EK) for roof gradients
15 to 85
- range of window leaf motion can be turned
by 145 to clean the outer surface
comfortably from the room
- control two-point press-up lock in the upper
part of the window (lower lock - optional)
- tilting-swinging version (EV) for roof
gradients 15 to 65
range of window leaf motion can be turned by
145 to clean the outer surface comfortablyfrom the room can be tilted by up to 45 out of
the roof gradient, or you can carry out both
motions simultaneously
- control lower lock
flashing painted aluminium sheet (copper
flashing - optional)
surface treatment versatile neutral glazing
(3 layers, 180 ), WHITE glazing - optional
thermostrips including
vent flap 20 m3 per hour with a dust filter
sealing 2 stages of sealing between the frame
and the window leaf 3rd stage of sealing in the
flashing
EXCELLENT roof windowwith vent flapproduct line with interesting
proportion of properties and price.
-
7/30/2019 Tagvinduer Uk
7/16FENESTRA 7
T H E R M I C A L
R
oofwindowswith
ventflap
glazing double glazing with a warm edge
U=1.1 W.m-2.K-1, acoustic insulation: 32 dB
thermal-insulation properties whole window
U=1.4 W.m-2.K-1
volume joint permeability iv:
0.24.10-4 m2.S-1.Pa-0.67
joint leakage rate mv = 0.0 l.h-1.m-1
warranty 10 years
Technical specifications: construction types
- swinging window (TK) for roof gradients
15 to 85
- range of window leaf motion can be turned
by 145 to clean the outer surface
comfortably from the room
- control two-point press-up lock in the upper
part of the window (lower lock - optional)
- tilting-swinging version (TV) for roof
gradients 15 to 65- range of window leaf motion can be turned
by 145 to clean the outer surface
comfortably from the room
- can be tilted by up to 45 out of the roof
gradient, or you can carry out both motions
simultaneously
- control lower lock
flashing painted aluminium sheet (copper
flashing - optional)
surface treatment versatile neutral glazing
(3 layers, 180 ), WHITE glazing - optional
thermostrips including
extra warm modification of windows range
vent flap 20 m3 per hour with a dust filter sealing 2 stages of sealing between the frame
and the window leaf, 3rd stage of sealing in the
flashing
glazing double glazing with a warm edge
U=1.1 W.m-2.K-1, acoustic insulation: 32 dB
thermal-insulation properties
whole window = 1,2 W.m-2.K-1
volume joint permeability
iv = 0,24.10-4 m2.S-1.Pa-0,67
joint leakage rate mv = 0,0 l.h-1.m-1
warranty 15 years (if installed with the
THERMOS heat insulation set)
THERMICAL roof windowwith vent flapThe best roof window in Czech
Republic for extraordinary thermal-insulation properties Winner of prixZlat taka 2007
Facade window
FENESTRA Facade windows are designed to be assembled solely with roof windows.They aresuitable for composition with windows in roofs ranging from 20 to 50. The window leaf tiltsround the lower axis, which enables ventilation even when raining. They provide a good view ofthe landscape even in buildings with high backing in the attic.
Dormer
without thermal insulation (SV)
The advantage of FENESTRA dormers is theirappearance - they look like roof windows.They
are supplied in the aluminium or copper versionfor all kinds of roofing, with roof gradientsbetween 20 and 65.They are not intended forthermally insulated rooms.
Anothertypesofroofwindow
s
-
7/30/2019 Tagvinduer Uk
8/168 R O O F W I N D O W S F U L L O F S U N
Another types of roof windows
Edging between the window and roofing
220
110
40
110
250
80
280
210
The lower part of the T edging is provided withpleated packing, which is easy to formaccording to the roofing profile. Foam sealingis installed onto the side and top parts to fill upthe gap between the edging and roofing. TheT edging includes a support of tiles to eventhe roof gradient above the window, and a
drain channel to lead water from the under-roof foil away from the window.
drainchannel
tiles support
back part ofedging Z
side parts ofedging B
front part ofedging P
pleatedpacking
100
150
220
110
40
110
80
drainchannel
back part ofedging Z
side parts ofedging B
front part of
edging P
T edging H edging
Edgingandcombiedging
Edging of FENESTRA roof windows is made of the same material as the
window flashing. It ensures watertightness with the roof gradient ranging
from 15 to 85 regardless of the roofing type. It is made of both-side painted
aluminium sheet, which does not need any maintenance.The universal dun
colour ensures tasteful incorporation of windows into the roofing of all
shades.We can produce copper-sheet edging on request.
Roof windows of garret type combine the benefits of classicalroof windows and dormer windows, eliminating their disadvantagesat the same time. They are suitable for roofs of gradients between
35 and 60. they offer a wide range of layout solutions in a living attic
no need of difficult interventions in the roof structure
you can locate them anywhere in the ground plan
they ensure extraordinary illumination of the room
they enable you to use the living area better, achieving a betterclearance height of the room near the roofing
they give you a panoramic view of the countryside
They eliminate the disadvantages of dormers:
high laboriousness
small amount of light coming just through a vertical window
no panoramic view out of the room
when using a bigger number of dormers, technical orarchitectonical issues may arise when designing the roofstructure
They eliminate the disadvantages of roof windows:
he living space utilized near the roofing is smaller
no panoramic view out of the room
Roof window of garret type
84 x 92 x 100 x 162 x 194 x 264 x 288 x 350 x(132-203) (132-203) (132-203) (132-203) (132-203) (132-203) (132-203) (132-203)
-
7/30/2019 Tagvinduer Uk
9/16FENESTRA 9
The unique manufacturing technology atautomatic forming centre enables, apart formother things, production of the upper part ofedging from one piece. This secures drain ofrainwater from the entire roof surface above thewindow, as well as absolute sureness ofwatertightness, even in winter, when snow oftenremains above the window, and thaws andfreezes again repeatedly.
COMBI-edging of the roof windows FENESTRA is a construction kit
system for flashing windows built in series. The entire system always
ensures absolute watertightness and a very simple assembly. Thanks to
the COMBI-edging, the number of variants is almost unlimited.
220
185
160
200
80
105
t can be used for welted tin roofing materials aswell. H edging includes a drain channel to lead waterrom the under-roof foil away from the window. Note:n case you use copper sheet roofing, it is notpossible to have the window edging made of adifferent material.
In case that copper-sheet roofing is used, itis not possible to have the window edgingmade of a different material.
drainchannel
back part ofedging Z
side partsof edging B
front partof edging P
N
slo
LD SD PD
LD PD
LN SN SN PN
LN SN SN PN
LD SD SD PDLD
U
V
PD
LN PN
T = separately fitted edging for profiled roofing materials (of total deep over 13 mm)
H = separately fitted edging for smooth roofing materials (of total deep up to 13 mm)
F = separately fitted edging for welted roofing materials
KT = COMBI-edging for profiled roofing materials (of total deep over 13 mm)
KH = COMBI-edging for smooth roofing materials (of total deep up to 13 mm)
KF = COMBI-edging for welted roofing materials
U distance of window frames adjacent in line
U = 14 cm standard, 11 - 21 cm on request (without thermal insulation)
20 cm standard, 17 - 27 cm on request
(with THERMOS heat insulation set)
V distance of window frames adjacent in column
V = 10 cm (without thermal insulation)
15 cm (with THERMOS heat insulation set)
The code labelling is described from the outside view(P = right, S = central, L = left, D = lower, N = above)
F edging
System of labelling and content of package
Edgingandcombi-edging
-
7/30/2019 Tagvinduer Uk
10/16
Interior roller blind RLwith side barsThey serve both to blank anddecorate the window. They arelead in aluminium bars, whicheliminates penetration of light onsides, and at the same timeenable the blind to be locked inany position. We recommendthem if you wish to blackout the
room. Versions available: BLACKOUT, other shades (shading,decorative function).
10 R O O F W I N D O W S F U L L O F S U N
Accesories of windows
Wide range of shading anddecorative accessories ensuresprotection against sunshine, andat the same time creates optimumconditions for living. Accessoriesof FENESTRA roof windows aredesigned to be easily and quicklyinstallable. All the roof windowsare delivered with built-in plastic
brackets for the outer hood.
Interior roller blind COLThey serve both to blank anddecorate the window. Available inseveral colour shades, including achildren's motif.
Sets of accesories CM a SMIf you buy a set of accesories
(interior roller blinds COL 3326 orinterior Al-blinds S 0872 togetherwith an exterior awning), you willsave 15% cost.
Interior roller blindEXTRAThe EXTRA roller blinds aremade of premium materials tosatisfy the most discerningcustomers.
Interior Al-blind, type SAluminium lamella blind lead by astring.Thanks to a special self-locking mechanism, the blind canbe locked in any position.Tiltingthe lamellas you can regulatepenetration of sunrays. It ensuresfull function (especially when fullclosing of lamellas is required)starting from the roof gradient of
45. (If blackout of the room isrequired, the RL BLACK OUTblind is the suitable one.)
Interior Al-blind, type LAluminium lamella blind lead inan Al-bar. Its function is the sameas with the type S blind. Slamellas move along the side Al-bars; they can be fully closedeven with smaller roof gradients.
(If blackout of the room isrequired,the RL BLACK OUTblind is the suitable one.)
An identification plate on each roof windowmakes ordering much easier, and at the sametime eliminates the possibility of delivering
accessories of a wrong size.
COL 718 TK 3326
Labelling of FENESTRA accessories
Colour shadeWindow dimension Window specificationKind of accessory
Accesoriesofwindows
Exterior awning MAThe exterior awning eliminatesthe incidence of solar radiation onthe roof window, reducing theamount of heat to penetrate theroom by up to 60 %. It is made ofblack PVC-netting, and it isalways controlled from the insideof the room. The awning is fixed
under the upper part of the roofwindow flashing.
Exterior roller blind PREElectronically controlledaluminium lamellas filled withpolyurethane hold back up to90 % of heat solar energy. Theouter roller blind providespleasant shading even during theday, and it as well ensuresadditional protection of the
insulation double glazing.
Exterior accessories protect the attic from solar heat energy. They are necessary
complement of all north-oriented roof windows. All FENESTRA roof windows are
supplied including built-in plastic carriers of an exterior awning.
-
7/30/2019 Tagvinduer Uk
11/16FENESTRA 11
Colour shades
Colour
shades
Colour shade of Interior rol ler bl inds
COL 3326
TERMO
COL 2082 COL 2147COL 2869COL 2135
STARLET ROTA 5 STARLET PERL STARLET TERMO
BLACKOUT 5085 BLACKOUT 3322BLACKOUT 5121BLACKOUT 5123 BLACKOUT 5118
OREGON 1
CALIFORNIA 2 CALIFORNIA 3CALIFORNIA 1
CHILDRENS MOTIF
RIO CONSTELLO 3607 CONSTELLO 4567
CONSTELLO 2751PARASOL OFFICE SFR 1229 VEROSAFE 144 VEROSAFE 3 BLOCKS 232
IVY BLANCHE 222BLOCKS 2421 MEDLEY655 MARBLE 204 MARBLE 5756 VEROGLIM 117
VEROGLIM 112VEROGLIM 113
MONACO 453
ODYSSEY 556 LINTEX 328 DT 3641 DT 3506
DT 660 DT 6905 DT 490 DT 7640 DT 3916 DT 10
Interior roller blinds COL and RL
Interior roller blinds RL BLACK OUT - to blackout the room
Interior roller blinds EXTRA (about price to contact FENESTRA Sales Department)
COL 100 COL 5080COL 4983 COL 204 COL 4979 COL 3869
Colour shade of
Interior Al bl inds
0001
0007
0017
0058
0062
0265
0378
0502
0558
0570
0700
0705
0707
0711
0712
0713
0714
0715
0716
0738
0780
0783
0811
0814
0872
-
7/30/2019 Tagvinduer Uk
12/1612 R O O F W I N D O W S F U L L O F S U N
control elements
Electric control EOHigh-positioned roof windows of OK, EK, and TKproduct lines can be opened and closed with anelectric remote control; the window leaf can beopened up to the distance of about 30 cm.
control unitpress button on the wall
unit of electric control
including set of holders
remote control heated sensor of rain and wind
Fire ventilationFor buildings, where exhaust of smoke is required in case of fire,we will supply a fire ventilation system.The safety equipment forsmoke exhaust can be used with windows of the OK, EK, and TKproduct lines. Concerning the price and use possibilities, pleas
contact our Sales Department.
CERTIFICATION: The company FK servis is certified to supplysystems of automatic ventilation equipment CertificateNo. TZUS 090-011 438
DESIGN: technical solutions designed the authorized companyFK servis.
PUTTING INTO OPERATION: FK servis will carry out functionaltests and issue a certificate of assembly and serviceability of theequipment.
ASSEMBLY - carried out by a company authorized bythe manufacturer, certified to implementsystem of fire ventilation (according to theFire Protection Law).
SERVICE - warranty and after-warranty service carriedout by an authorized company. Accordingto the Regulation No. 246/2001,serviceability of the equipment has to beinspected at least once a year.
CONTROL - requirements are based on the fire
protection report:from several spots (floors)several independent groupscombination with day ventilation
BACKUP - entire system is back-upped for at least 48hours.
electric drives toopen or close
windows
smoke detector
safety button
EPS connection
connection of externalcontrol systm
wind/rain detector
ventilation button
time switch
thermostat
Lower lock SPIn rooms where you can only reach the lower partof the window, we can supply a roof window witha lower handle (supply of tilting-swinging windowswith lower lock is standard). A window with alower lock cannot be controlled remotely.
Telescopic control stick OTThe control stick can be lengthened up to 2 m andwith it, you can control the window leaf of OK, EK,and TK product lines with an upper press-up lockpositioned up to 4 meters above the floor level. Notavailable for windows with lower lock.
Cord control POCord control is used to control roof windows of OK,EK, and TK product lines positioned even higherthan in the previous cases. It can be installedadditionally onto an already fitted window with anupper press-up lock. Not available for windows withlower lock.
controlelements
-
7/30/2019 Tagvinduer Uk
13/16FENESTRA 13
LiningTo utilize all functions of a top-quality roof window fully, it is necessaryto fit the window recess lining (facing) correctly. This will ensuremaximum illumination of the room (30 - 40 % bigger amount of lightthan with a dormer window with the same glazing surface), not affectingthe natural air circulation around the window pane. This way, theprobability of condensation of the interior moisture on the surface of theinsulating double-glazing will be considerably reduced.
WRONG FITTING
Selection of placing height and optimum size of windowThe selection of the window placing height is influenced by several factors - theroof structure gradient, quality of view, illumination of the future room, etc. Donot forget, however, that you must be able to control the window handle and theouter hood comfortably and clean both sides of the double glazing easily.Therefore, the upper edge should not be higher than 200 cm. According to the
roof gradient, we choose such a window size that gives us a good view both instanding and sitting positions (the lower edge of the window frame should beabout 90 cm from the floor).
IlluminationTo illuminate a room optimally, the total glazing surface of windows should reachat least 10 % of the floor surface.The number and size of roof windows influencesufficient amount of light in the room, good space arrangement, as well as a goodview. More roof windows enable more uniform illumination ratio than one largewindow (even with the same surface of glazing).
Eventual adaptation of raftersAdaptation of rafters is only necessary if the distance between rafters (d) issmaller than the window width (w) or bigger than the window width extended by200 mm (d > w + 200 mm). Adaptation above and below the window must bedone in a sufficient distance from the window leaf to enable fitting of the lininghorizontally above the window, and vertically below it.
g
eneralprinciples
The following principles must be observed:
It is optimal to locate heating elements
directly below the roof windows.
Warm air should flow round the lower
part of the window.
The lining must be vertical below the
window, and horizontal above it.
-
7/30/2019 Tagvinduer Uk
14/16
max.20mm
80-100
mm
max
.140
mm
max.100mm
max.20mm
max
.
50
mm
80-100
mm
14 R O O F W I N D O W S F U L L O F S U N
Important things during installation
observing of given distances
meeting of hydroisolation foil and placing of drain channel
Importantthingsduringinstallation levelling of roof cracks
closing of roof covering to the highrib of edging
-
7/30/2019 Tagvinduer Uk
15/16FENESTRA 15
special kinds of assembly
ridge tile tinsmith-made ridge part of edging
thermal insulation
ridge beam
bituminousstrip
lining
insmith-made ridgepart of edging
boarding
steel support
roofing material
roofing material
roof windowroof window
snow stopper- round log
snow stopper
support - wedge
Lifting framedesigned for roofs of gradient lower than 15.
Snow stoppersIn the mountains, we recommend to protect your roof windowsagainst the sliding snow cover.
Curved roofing Insulation over the roof truss
Windows in the ridge
roof window
tinsmith-made parts according tothe roofing curvature at the spot ofwindows fitting
T edging inprofiled roofingmaterial
offset frame madeby carpenter'sexchange
with horizontal rafters and profiled roofing material
edging
roof window
offset prism
insulation part
rafter
insulation partoffset prism
direction the insulation part should be cut in, to achieve correct lining
tinsmith-made ridge part of edging
specialkindsofasse
mbly
-
7/30/2019 Tagvinduer Uk
16/16