COURTYARD
COURTYARD
TYPE
TYPE
BEDROOM3900X 4210
BEDROOM3300 X 4210
MASTERBEDROOM3650 X4575
LIVING3350 X4325
KITCHEN3050 X2472
OPEN3415 X3415
KIDS TOI2515 X1733
GUEST TOI2285 X1500
MASTER TOI1675 X2750
SIT OUT5300X 1500
SIT-OUT1720X 1500
SIT-OUT2060X 1200
SIT-OUT2060X 1200
GUEST TOI2285X 1500
BEDROOM4210 X 3300
LIVING3580 X 4640
DINING4130 X 2940
KITCHEN2265X3050
BEDROOM3665 X 3050
SIT-OUT2325X 1500
GUEST TOI2550X1700
MASTERBEDROOM4500 X 3600
MASTER TOI 2400X 1570
KIDS TOI1685 X 2400
BEDROOM4250 X 3050
KITCHEN2700X2325 STUDY
3360 X 2865
MASTERBEDROOM4575 X 3650
SIT-OUT3765X1500
SIT OUT5565X 1500
SIT-OUT4235 X 1500
MASTER TOI1650 X2485
COURTYARD
COURTYARD
LIFT10 PERSONS
LIFT10 PERSONS
Tread-300Riser-150
NO. OF STEPS-20
Width-900
Tread-280Riser-150
NO. OF STEPS-20
Width-1150
UPDNUPDN
STILT STILT
1050 HIGH RAILING
1050 HIGH RAILING
SHAFTELE
LIFT15 PERSONS
LVL+150 LVL+150
LVL+250
LVL ±00
2D
2D
3D
3D
3D
D
4DW
3DW
6DW
4DW
1D
V
V
V
1W
3W
1D
2D
1D
1D
3D
1D
D
D
4DW
5DW
3DW
DW
1DW
3D
V
3D
3D
3D
1DW
V
3D
2DW
2D
W
W
2W
3W
V1
V
V
V
3W
W
2D
2D
3D
3D
3D
D
4DW
3DW
6DW
4DW
1D
V
V
V
1W
3W
1D
2D
1D
1D
3D
1D
D
D
4DW
5DW
3DW
1DW
3D
V
3D
3D
3D
1DW
V
3D
2DW
2D
W
W
2W
3W
V1
V
V
V
DW
3W
W
LVL+250
LVL+
250
LVL ±00
LVL ±00
MASTERBEDROOM1500 X 3600
TOI 2400X 1685
TOI1570 X 2400
BAL5565X 1200
1D
1
3D
1DW
VV
V''
Q''
R''
U''
B''
C''
D''
E''F''
J''K''
L''
M''N''
O''
P''
G''
H''
I''
S''T''
T- 4to8
GD A''
B'C'
D'
E'
F'
G'
H'I'
J'
K'
L'
M'
N'
O'
P'
Q'R'
S'
T'
U'
V'
T -4 t
o 8 G
D A'2'
3'
4'5'
6'
7'
8'
9'
10'
12'
11'
T- 4 t
o 8 G
D 1'
B C D E F G H I J K L M N O P Q R S T V W
16
14
12
11
10
9
8
7
6
13
X Y
15
2
3
4
5
T- 4 to 8 GD A
T- 4 to 8 GD 1
I1 K1 L1 M1 N1 P1F1 G1 R1 S1
DINING4695 X 3040
LIVING3115 X 4810
DINING4365 X 3280
TYPE
TYPE
TYPE
TYPE
B C D E F G H I J K L M N O P Q R S T V W
16
14
12
11
10
9
8
7
6
13
X Y
15
2
3
4
5
T- 4 to 8 GD A
T- 4 to 8 GD 1
I1 K1 L1 M1 N1 P1F1 G1 R1 S1
GROUND FLOOR PLAN
8
191
8
8
2
8 88
8
88
8
2 299
11
8
8
PIPE SHIFTED8
8
2
PIPE SHIFTED
PIPE SHIFTED
PIPE SHIFTED2
PIPE SHIFTED
PIPE SHIFTED
PIPE SHIFTED
PIPE SHIFTED
PIPE SHIFTED
PIPE SHIFTED
1
2
8
8
8 8
2 2
DRG. TITLE
PARTICULARS
1. ALL DRAWINGS ARE IN MM.
6. THE BEAM, FROM WHERE THE TOILET PIPES ARE GOING TOWARDS
GROUND FLOOR & CEILING
SCALE1:100
DEALTRAJESH
V A S T U N I D H IARCHITECT:
B-135, SECTOR 44,NOIDAARCHITECT, PLANNER & INT. DESIGNERS
PHONE:2432190 FAX:4331407
PROJECT:
LAVANYA HOUSINGVILLAGE BHANKROTA, AJMER ROAD, JAIPUR
CLIENT:
208,OCEAN COMPLEX SEC-18,NOIDA
NORTH
REV. NO.
DRG. NO.
22.04.15DATE
TOWER NO.
MAJESTIC PROPERTY PVT. LTD.
THIS DRAWING IS THE PROPERTY OF M/SVASTUNIDHI AND SHALL NOT BE REPRODUCEDOR USED FOR ANY OTHER PURPOSE THANSPECIFIED WITHOUT WRITTEN PERMISSION
TOWER NO. T1 TO T8
CHECKEDMAHENDRA
PRINT DATA:S.NO. DATE (PRINTS) ISSUED TO
REVISIONS:S.NO. REV.NO.
NO.
2. THIS DRAWING IS NOT TO BE SCALED.
OTHER RELEVANT DRAWINGS.3. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH
NOTES:
4. ANY AMBIGUITY FOUND SHOULD BE REFERRED TO THE ARCHITECT
THE SHAFTS, HAS TO BE UPTURNED OR OTHERWISE AS SPECIFIED.
5. RW PIPES ARE DIVERTED TO PIPE LOCATION AS SHOWN. BEFORE EXECUTION.
N
CT(4TO8)-PL-4
I-HOMES AND
R3
KAKROLA ROAD NAJAFGARHNEW DELHI-110043PH:- [email protected]
1/30 ROSHAN GARDEN-IIARK CONSULTANTSPLUMBING CONSULTANTS
DESCRIPTIONMARK
1
LEGEND FOR PLUMBING
110(OD) uPVC SOIL,WASTE & VENT PIPE
2 110(OD) uPVC WASTE & VENT PIPE
3
4
8
11
75(OD) uPVC ANTI-SYPHONIC PIPE
9
10
5
6
7
DOMESTIC WATER SUPPLY PIPED.W.S
HOT WATER SUPPLY PIPEH.W.S
FLUSHING WATER SUPPLY PIPE
FLOOR TRAPF.T
BALCONY DRAINB.D
GALVANIZED IRONG.I
OUTER DIAOD
F.W.S
40Ø G.I D.W.S O.H WATER TANK FILLING PIPE FROM PUMP ROOM
32Ø G.I F.W.S O.H WATER TANK FILLING PIPE FROM S.T.P
DOMESTIC WATER SUPPLY DOWNTAKE PIPE FOR 8th & 7th FLOOR
DOMESTIC WATER SUPPLY DOWN TAKE PIPE 6th TO STILT FLOOR
FLUSHING WATER SUPPLY DOWN TAKE PIPE 8th FLOOR TO STILT FLOOR
75(OD) uPVC RAIN WATER PIPE FOR BALCONY
110(OD) uPVC RAIN WATER PIPE FOR TERRACE
H.W.S PIPE FROM SOLAR PANEL FOR KITCHENS
DESCRIPTIONMARK
PLUMBING NOTE:-
* W.C TO VERTICAL SOIL STACK 110(OD) uPVC SOIL PIPE* F.T TO VERTICAL WASTE STACK 110(OD) uPVC WASTE PIPE
* WASH BASIN TO F.T 40(OD) uPVC WASTE PIPE* SINK TO F.T FLEXIBLE PIPE
a ONE NO. M.S FIRE CABINET SIZE 2100x900x600mm
b
c
ONE NO. 63mmØ SINGLE LANDING VALVE
LEGEND FOR FIRE FIGHTING
ONE NO. FIRE HOSE REEL WITH DRUM 20mmØ x36.5M. LONG
d TWO NOS. 63mmØ x15M. LONG RRL HOSE PIPES
ONE NO. BRANCH PIPEe
4.5 Kg CO2 TYPE FIRE EXTINGUISHER
FHC= FIRE HOSE CABINET COMPRISING OF
5.0 Kg. ABC TYPE FIRE EXTINGUISHER
PLAN (PLUMBING)
9 9
FT
8
BD
8
8
5472
5472
5413
6
5472
54
1
6
3
FT
54
6
5472
5472
8
8
8
8
13
45
6
13
45
6
FT
FT
1
9
9 9
FHC FHC
DOWN-COMER PIPE100Ø M.S FIRE
FIRE CUTOUT SIZE=300x300mm DOWN-COMER PIPE
100Ø M.S FIRE
FT
FT
FT
FT
FT
FT
FT
FT
FT
FT
T-01
T-02
T-03
T-04
T-05
K-01
K-01
K-01 K-01
T-06
T-04
T-03
T-07
T-08
T-05
T-04
T-04
T-06
K-01
K-01PLUMBING SHAFTSIZE=820x600mm
PLUMBING SHAFTSIZE=820x600mm
54
1
6
3
FT
T-06T-06
FT
16
13
13
45
6
3
84
5
85
16
3
5472
FT
65
14
6541
4
16
3
84
5
85
16
3
4
8
1
FT FT
1 1
19
9 9
11
34
629
5
FT
F.T
FT
65
4
3
1
91
FD T-09
T-10
V''
Q''
R''
U''
B''
C''
D''
E''F''
J''K''
L''
M''N''
O''
P''
G''
H''
I''
S''T''
T- 4to8
GD A''
B'C'
D'
E'
F'
G'
H'I'
J'
K'
L'M'
N'
O'
P'
Q'R'
S'
T'
U'
V'
T -4 t
o 8
GD A'
2'
3'4'
5'
6'
7'
8'
9'10
'
12'
11'
T- 4 t
o 8 G
D 1'
B C D E F G H I J K L M N O P Q R S T V W
16
14
12
11
10
9
8
7
6
13
X Y
15
2
3
4
5
T- 4 to 8 GD A
T- 4 to 8 GD 1
I1 K1 L1 M1 N1 P1F1 G1 R1 S1
LIFT10 PERSONS
LIFT10 PERSONS
OPEN TO SKY
CORRIDOR
DNDN
LIFT15 PERSONS
OPEN TO SKY
OPEN TO SKYOPEN TO SKYOPEN TO SKY
OPEN TO SKY
OPEN TO SKY
SLOPE
SLOPE
RID
GE
RID
GE
VALLE
Y
VALLE
Y
RID
GEV
ALLE
YSL
OPESLOPE
RIDGE
VALLEY
SLOPE
VALLEY
RIDGE
RIDGE
SLOP
EVALLEY
SLOPE
RIDGE
SLOPE
SLOPE
VALLEY
SLOPE
VALLEY
VA
LLEY
SLOP
E
SLOPE
LIFT
DN
SHAFT
LIFT
LIFT
SHAFT
UP
FHC BV
B.V
BV
BV
BFV
KHURRASIZE=450x450mm
KHURRASIZE=450x450mm
KHURRASIZE=450x450mm
COMER PIPE WITH AIR RELEASE VALVE AT TOP
100Ø M.S FIRE DOWN
32Ø F.W.S 40Ø D.W.S 25Ø D.W.S
32Ø F.W.S 40Ø D.W.S 25Ø D.W.S
32Ø F.W.S 40Ø D.W.S 25Ø D.W.S
32Ø D.W.S 20Ø D.W.S 40Ø H.W.S
32Ø F.W.S 40Ø D.W.S
80Ø F.W.S
65Ø D.W.S 80Ø F.W.S
40Ø F.W.S 50Ø D.W.S 32Ø D.W.S
32Ø D.W.S 20Ø D.W.S 40Ø H.W.S
32Ø D.W.S 20Ø D.W.S 40Ø H.W.S
32Ø F.W.S 40Ø D.W.S 25Ø D.W.S
32Ø F.W.S 40Ø D.W.S 25Ø D.W.S
80Ø D.W.S RING 65Ø F.W.S RING
80Ø D.W.S RING 65Ø F.W.S RING
40Ø H.W.S
50Ø H.W.S
80Ø D.W.S 65Ø F.W.S
5 SET
OF 500
Ltr. C
APACITY SOLA
R
PANELS REQ
UIRED (5
COLLECTO
RS IN ONE S
ET)
BYE PASS LI
NE
50Ø H.W.S 50Ø D.W.S
150Ø M.S FIRE PIPETO TOWER 3 &4FIRE PUMP DELIVERY HEADER
FHC
BV
BV
BV
BV
BV
BV
BV
40Ø D.W.S O.H WATERTANK FILLING PIPE UP
BFVKHURRASIZE=450x450mm
32Ø F.W.S 40Ø D.W.S 25Ø D.W.S
32Ø D.W.S 20Ø D.W.S 40Ø H.W.S
40Ø D.W.S 25Ø D.W.S
32Ø F.W.S
40Ø D.W.S 25Ø D.W.S
32Ø F.W.S 40Ø D.W.S 25Ø D.W.S
32Ø F.W.S 40Ø D.W.S 25Ø D.W.S
32Ø D.W.S 20Ø D.W.S 40Ø H.W.S
32Ø F.W.S 40Ø D.W.S 25Ø D.W.S
65Ø F.W.S 80Ø D.W.S
COMER PIPE WITH AIR RELEASE VALVE AT TOP
100Ø M.S FIRE DOWN
80Ø D.W.S
32Ø D.W.S 20Ø D.W.S 40Ø H.W.S
32Ø D.W.S 50Ø D.W.S 40Ø F.W.S
5 SET
OF 500
Ltr. C
APAC
ITY SOLA
R
PANEL
S REQUIRED
(5 COLL
ECTO
RS IN ONE S
ET)
BYE PA
SS LINE
50Ø H.W.S 50Ø D.W.S
40Ø H.W.S
40Ø H.W.S
50Ø H.W.S
80Ø D.W.S RING 65Ø F.W.S RING
80Ø D.W.S 65Ø F.W.S
150Ø M.S FIRE PIPEFIRE PUMP DELIVERY HEADER150Ø M.S FIRE PIPE
TO TOWER 6,7 & 8FIRE PUMP DELIVERY HEADER
100Ø M.S FIRE PIPE
BV
100Ø D.W.S PIPE FROM O.H WATER TANK
150Ø M.S FIRE PIPEFROM UPPER TERRACE
BV
BV
BV
BV BV
BV
BVKHURRA
SIZE=450x450mm
BV
KHURRASIZE=450x450mm
KHURRASIZE=450x450mm
5 SET OF 500 Ltr. CAPACITY SOLAR PANELS REQUIRED (5 COLLECTORS IN ONE SET)
32Ø D.W.S 40Ø D.W.S
32Ø H.W.S 32Ø D.W.S 20Ø D.W.S
32Ø H.W.S 20Ø D.W.S 32Ø D.W.S
32Ø F.W.S 40Ø D.W.S 25Ø D.W.S
32Ø H.W.S
32Ø D.W.S 20Ø D.W.S
32Ø H.W.S 32Ø D.W.S 20Ø D.W.S
40Ø D.W.S 32Ø F.W.S
50Ø D.W.S 50Ø F.W.S
40Ø F.W.S
32Ø D.W.S 40Ø D.W.S
32Ø F.W.S 25Ø D.W.S 40Ø D.W.S
32Ø F.W.S 40Ø D.W.S 25Ø D.W.S
BYE PASS LINE
80Ø D.W.S RING 65Ø F.W.S RING
80Ø D.W.S RING 65Ø F.W.S RING
80Ø D.W.S RING 65Ø F.W.S RING
80Ø D.W.S RING 65Ø F.W.S RING
50Ø H.W.S 50Ø D.W.S
40Ø H.W.S
40Ø H.W.S
50Ø H.W.S
BV
BV
40Ø D.W.S
32Ø F.W.S
5472
54
1
6
3
5472
5472
65
1
3
4
54
1
6
3
65
1
3
4
65191
43
45
72
45
72
5472
5472
745 2 7 4 52
13
45
6
4391
56
2
3
56
1
4
61
35
4
40Ø D.W.S 25Ø D.W.S
61
35
4
61
34
5
9
SCALE
DEALT
V A S T U N I D H IARCHITECT, PLANNER & INT. DESIGNERSB-28, SECTOR 44,NOIDAPHONE:2432190 FAX:4331407
MELANGE JEWELSVILLAGE BHANKROTA, AJMER ROAD, JAIPUR
208,OCEAN COMPLEX SEC-18,NOIDA
NORTH
REV. NO.
DRG. NO.
22.04.15
MAJESTIC PROPERTY PVT. LTD.
TOWER NO.-T5 (FOR FIRE PIPING
THIS DRAWING IS THE PROPERTY OF M/SVASTUNIDHI AND SHALL NOT BE REPRODUCEDOR USED FOR ANY OTHER PURPOSE THANSPECIFIED WITHOUT WRITTEN PERMISSION
CHECKEDMAHENDRA
PRINT DATA:DATE (PRINTS)
REVISIONS:REV.NO.
NO.
OTHER RELEVANT DRAWINGS.3. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH 2. THIS DRAWING IS NOT TO BE SCALED.1. ALL DRAWINGS ARE IN MM.
BEFORE EXECUTION.4. ANY AMBIGUITY FOUND SHOULD BE REFERRED TO THE ARCHITECT
5. RW PIPES ARE DIVERTED TO PIPE LOCATION AS SHOWN.
THE SHAFTS, HAS TO BE UPTURNED OR OTHERWISE AS SPECIFIED. 6. THE BEAM, FROM WHERE THE TOILET PIPES ARE GOING TOWARDS
CT(4TO8)-PL-6RAJESH
DATE
N
T-4
T-5
T-6
T-7
T-8
1:100
KAKROLA ROAD NAJAFGARHNEW DELHI-110043PH:- [email protected]
1/30 ROSHAN GARDEN-IIARK CONSULTANTS
PLUMBING CONSULTANTS
DESCRIPTIONMARK
1
LEGEND FOR PLUMBING
110(OD) uPVC SOIL,WASTE & VENT PIPE
2 110(OD) uPVC WASTE & VENT PIPE
3
4
8
11
75(OD) uPVC ANTI-SYPHONIC PIPE
9
10
5
6
7
DOMESTIC WATER SUPPLY PIPED.W.S
HOT WATER SUPPLY PIPEH.W.S
FLUSHING WATER SUPPLY PIPEF.W.S
40Ø G.I D.W.S O.H WATER TANK FILLING PIPE FROM PUMP ROOM
32Ø G.I F.W.S O.H WATER TANK FILLING PIPE FROM S.T.P
DOMESTIC WATER SUPPLY DOWNTAKE PIPE FOR 8th & 7th FLOOR
DOMESTIC WATER SUPPLY DOWN TAKE PIPE 6th TO STILT FLOOR
FLUSHING WATER SUPPLY TANK PIPE 8th FLOOR TO STILT FLOOR
75(OD) uPVC RAIN WATER PIPE FOR BALCONY
110(OD) uPVC RAIN WATER PIPE FOR TERRACE
H.W.S PIPE FROM SOLAR PANEL FOR KITCHENS
DESCRIPTIONMARK
a ONE NO. M.S FIRE CABINET SIZE 2100x900x600mm
b
c
ONE NO. 63mmØ SINGLE LANDING VALVE
LEGEND FOR FIRE FIGHTING
d
TWO NOS. 63mmØ x15M. LONG RRL HOSE PIPES
ONE NO. BRANCH PIPE
FHC= FIRE HOSE CABINET COMPRISING OF
TOWER-T1 TO T8 REFER COMBINDTERRACE FLOOR PLAN)
BV
80Ø F.W.S PIPE FROM
32Ø F.W.S O.H WATERTANK FILLING PIPE UP
O.H WATER TANK
SLOP
E
25Ø D.W.S
TERRACE FLOOR PLAN(PLUMBING)
DRG. TITLE
32Ø O.H FLUSHING WATERTANK FILLING PIPE
40Ø O.H DOMESTIC WATERTANK FILLING PIPE
1
34
5
6
B.V
B.F.V
B.F.V
345 16
99
3 4 51 6
345
16
345
16 BV
BV
40Ø D.W.S
32Ø F.W.S
25Ø D.W.S
BV
6511109
43
1
9
BV
61
34
5
BV 32Ø F.W.S
5472
54
6
3
54
6
13
BVBV
BV
BV
BV
32Ø F.W.S
19
9 9
BV
9
32Ø F.W.S 25Ø D.W.S 40Ø D.W.S
3 1456 31 4 5 6
M'
P' R'
E''
J''J P
6
3
4
I1 K1 L1 M1 N1 P1
1
230 MM THK. 450MMHIGH PARAPET
230 MM THK. 450MMHIGH PARAPET
230 MM THK. 450MMHIGH PARAPET
230 MM THK. 450MMHIGH PARAPET
230 MM THK. 300MM HIGH PARAPET
230 MM THK.300MM HIGH PARAPET
1390 13903315 3315
230 MM THICK 300MM HIGH PARAPET
230 MM THK. 300MMHIGH PARAPET
230 MM THK.450MMHIGH PARAPET
230 MM THK.300MMHIGH PARAPET
230 MM THK. 300MMHIGH PARAPET
230 MM THK. 300MMHIGH PARAPET
230 MM THK. 450MMHIGH PARAPET
230 MM THK.300MMHIGH PARAPET
1385 34051385
1385
1385
1945
1945
1385
1385
2265
2265
835
3780
2380
1315
1430
1685
465
550 25
15
410 18
80
2290
690
1825
1015
2035
1315
3760
370
LIFT10 PERSONS
LIFT10 PERSONS
TYPE TYPE
COURTYARD
TYPE TYPE
TOI
COURTYARD BELOW
TYPE
TYPE
TYPE TYPE
COURTYARD
TYPE
TYPE
TYPICAL FLOORBLOCK OF TEN
OPEN TO SKY
935 720 3895 2265 14301685
665 2400 2290 2290 2400665 465
1685 1430 2265 3895 720 980
3715
985
2325
770
900
445 98
0
38320
835
3780
2380
1315
1430
1685465
550
2515
410
1880
2290
690
1825
1015
2035
1315
3760
370
3715610
1500
348
707
655
650
1675
3715
610
1500
348
707
915
1910
600
655
650
1675
COURTYARD BELOW
COURTYARD BELOW
CORRIDOR
CORRIDOR
CORRIDOR
UPDNUPDN
935
985 980935
1055
1500
610
9801430
465 1430 935
915
1910
600
2130 2245 2525 1675 2850 2205 1995 2245 2130
2530
700
2130
625
3
2
5DW
3DWDW1
DW
2D
D D
1D
1D
1D
3D
D
3D
3D
3D
3D
D
2DW
4DW
V
V
V
V
V
W
2W
W
1D
3W
1DW
COURTYARD BELOW
COURTYARD BELOW
2D
2D
3D
3D
3D
D
4DW
3DW
6DW
4DW
1D
V
V
V
1W
3W
1D
2D
1D
1D
3D
1D
D
D
4DW
5DW
3DW
DW
1DW
3D
V
3D
3D
3D
1DW
V
3D
2DW
2D
W
W
2W
3W
V1
V
V
V
3W
W
2D
2D
3D
3D
3D
D
4DW
3DW
6DW
4DW
1D
V
V
V
1W
3W
1D
2D
1D
1D
3D
1D
D
D
4DW
5DW
3DW
1DW
3D
V
3D
3D
3D
1DW
V
3D
2DW
2D
W
W
2W
3W
V1
V
V
V
DW
3W
W
1D
1DW
3D
3D
1DW
V
MASTERBEDROOM1500 X 3600
TOI 2400X 1685
TOI1570 X 2400
BEDROOM4250 X 3050
BAL.3765X1200
BAL5565X 1200
V
B'C'
D'
E'
F'
G'
H'I'
J'
K'
L'
M'N'
O'
P'
Q'R'
S'
T'
U'
V'
T -4 t
o 8 G
D A'
V''
Q''
R''
U''
B''
C''
D''
E''F''
J''K''
L''
M''N''
O''
P''
G''
H''
I''
S''T''
T- 4to8
GD A''
3246
0 32460
1328
5
13285
5985
B C D E F G H I J K L M N O P Q R S T V W
16
14
12
11
10
9
8
7
6
13
X Y
15
2
3
4
5
T- 4 to 8 GD A
T- 4 to 8 GD 1
I1 K1 L1 M1 N1 P1F1 G1 R1 S1
2'
3'
4'
5'6'
7'
8'
9'
10'
12'
11'
T- 4 t
o 8 G
D 1'
1844
B C D E F G H I J K L M N O P Q R S T V W
16
14
12
11
10
9
8
7
6
13
X Y
15
2
3
4
5
T- 4 to 8 GD A
T- 4 to 8 GD 1
I1 K1 L1 M1 N1 P1F1 G1 R1 S1
WINDOW SHIFTED
T-7
R4
CLIENT:
I-HOMES AND
DRG. TITLE
SCALE1:100
DEALTRAJESH
ARCHITECT:
V A S T U N I D H IARCHITECT, PLANNER & INT. DESIGNERSB-135, SECTOR 44,NOIDAPHONE:2432190 FAX:4331407
PROJECT:
LAVANYAVILLAGE BHANKROTA, AJMER ROAD, JAIPUR
NORTH
REV. NO.
DRG. NO.
DATE22.04.15
TOWER NO.
TYPICAL FLOOR PLAN (PLUMBING)
TOWER NO. T1 TO T8
THIS DRAWING IS THE PROPERTY OF M/SVASTUNIDHI AND SHALL NOT BE REPRODUCEDOR USED FOR ANY OTHER PURPOSE THANSPECIFIED WITHOUT WRITTEN PERMISSION
CHECKEDMAHENDRA
PRINT DATA:S.NO. DATE (PRINTS) ISSUED TO
REVISIONS:S.NO. REV.NO. PARTICULARS
NO.
OTHER RELEVANT DRAWINGS.3. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH 2. THIS DRAWING IS NOT TO BE SCALED.1. ALL DRAWINGS ARE IN MM.
NOTES:
BEFORE EXECUTION.4. ANY AMBIGUITY FOUND SHOULD BE REFERRED TO THE ARCHITECT
5. RW PIPES ARE DIVERTED TO PIPE LOCATION AS SHOWN.
THE SHAFTS, HAS TO BE UPTURNED OR OTHERWISE AS SPECIFIED. 6. THE BEAM, FROM WHERE THE TOILET PIPES ARE GOING TOWARDS
N
T-4
T-5
T-6
T-8
CT(4TO8)-PL-5
208,OCEAN COMPLEX SEC-18,NOIDAMAJESTIC PROPERTY PVT. LTD.
KAKROLA ROAD NAJAFGARHNEW DELHI-110043PH:- [email protected]
1/30 ROSHAN GARDEN-IIARK CONSULTANTSPLUMBING CONSULTANTS
DESCRIPTIONMARK
1
LEGEND FOR PLUMBING
110(OD) uPVC SOIL,WASTE & VENT PIPE
2 110(OD) uPVC WASTE & VENT PIPE
3
4
8
11
75(OD) uPVC ANTI-SYPHONIC PIPE
9
10
5
6
7
DOMESTIC WATER SUPPLY PIPED.W.S
HOT WATER SUPPLY PIPEH.W.S
FLUSHING WATER SUPPLY PIPE
FLOOR TRAPF.T
BALCONY DRAINB.D
GALVANIZED IRONG.I
OUTER DIAOD
F.W.S
40Ø G.I D.W.S O.H WATER TANK FILLING PIPE FROM PUMP ROOM
32Ø G.I F.W.S O.H WATER TANK FILLING PIPE FROM S.T.P
DOMESTIC WATER SUPPLY DOWNTAKE PIPE FOR 8th & 7th FLOOR
DOMESTIC WATER SUPPLY DOWN TAKE PIPE 6th TO STILT FLOOR
FLUSHING WATER SUPPLY DOWN TAKE PIPE 8th FLOOR TO STILT FLOOR
75(OD) uPVC RAIN WATER PIPE FOR BALCONY
110(OD) uPVC RAIN WATER PIPE FOR TERRACE
H.W.S PIPE FROM SOLAR PANEL FOR KITCHENS
DESCRIPTIONMARK
PLUMBING NOTE:-
* W.C TO VERTICAL SOIL STACK 110(OD) uPVC SOIL PIPE* F.T TO VERTICAL WASTE STACK 110(OD) uPVC WASTE PIPE
* WASH BASIN TO F.T 40(OD) uPVC WASTE PIPE* SINK TO F.T FLEXIBLE PIPE
a ONE NO. M.S FIRE CABINET SIZE 2100x900x600mm
b
c
ONE NO. 63mmØ SINGLE LANDING VALVE
LEGEND FOR FIRE FIGHTING
ONE NO. FIRE HOSE REEL WITH DRUM 20mmØ x36.5M. LONG
d TWO NOS. 63mmØ x15M. LONG RRL HOSE PIPES
ONE NO. BRANCH PIPEe
4.5 Kg CO2 TYPE FIRE EXTINGUISHER
FHC= FIRE HOSE CABINET COMPRISING OF
5.0 Kg. ABC TYPE FIRE EXTINGUISHER
F.T
FT
B.D8
BD
8
6
BD
B.D
B.D
BD
5191
43
8
8
FT
45
72
345 16
B.D8
BD
8
BD
8
BD
FT
B.D 8B.D 8
B.D
B.D
8
845
72
5472
5472
5472
9
FTFT
54
1
6
3
FT
54
6
5472
5472
BD
8
BD8
BD
8
BD
8
8
8
BD
BD
8
8
745 2 7 4 52
13
45
6
1
13
45
6
FT
FT
FT
FT
9
9
9 9
FHC FHC
DOWN-COMER PIPE100Ø M.S FIRE
FIRE CUTOUT SIZE=300x300mm DOWN-COMER PIPE
100Ø M.S FIRE
FTFT
FT
FT
FT
FT
FT
FT
FT
FT
FT
FT
FT
FT
FT
FT
FT
T-01A
T-02A
T-03
T-04
T-05
K-01
T-05
K-01
K-01
K-01
T-04
T-01
T-02
T-03
T-01
T-02
T-03
T-04
T-05
K-01
K-01
K-01 K-01
T-06
T-04
T-03
T-07
T-08
T-05
T-04
T-04
T-06
K-01
K-01
99
PLUMBING SHAFTSIZE=820x600mm
PLUMBING SHAFTSIZE=820x600mm
PLUMBING SHAFTSIZE=820x600mm
6511109
43
FT
FT
54
1
6
3
FT
FT T-06T-06
653
41
1
FT
16
BD
13
1 638 5
B.DB.D
13
45
6
3
84
5
BD
85
16
3
3 4 51 6
4 16 3 854
5472
FT
65
1
3
4
65
3
41
4
BD 16
3
84
5
85
16
3
4
8
54
6
13
9
653
41
1
PLUMBING SHAFTSIZE=820x600mm
34
629
5
FT
F.T
65
4
3
1
91
T-09
T-10
655
330
115
WINDOW SIZE CHANGE WINDOW SIZE CHANGE
TERRACE FLOOR.
GROUND FLOOR.
8th FLOOR.
7th FLOOR.
6th FLOOR.
5th FLOOR.
4th FLOOR.
2nd FLOOR.
3rd FLOOR.
1st FLOOR.
BASEMENT FLOOR
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILETTO TOILET
TO TOILET
1'-2'A'-C'
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
6'-7'D'-E'
9'-11'E'-F'
9'-11'H'-I'
3'-4'K'-L'
8'-12'M'-N'
8'-11'N'-O'
3'-4'O'-Q'
7'-9'Q'-S'
3'-5'T'-U'
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
100Ø FIRE WETRISER PIPE
LV
FHCLV
FHR
BFV
N.R.
V
2 WAY FIRE BRIGADE INLET CONNECTION
4669
LV
100Ø FIRE WETRISER PIPE
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
100Ø FIRE WETRISER PIPE
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILETTO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILETTO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILETTO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILETTO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILETTO TOILET
TO TOILET
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILETTO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILETTO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
3'-5'B''-C''
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
100Ø FIRE WETRISER PIPE
LV
VALVE
FHCLV
FHR
BFV
N.R.
V
LV
100Ø FIRE WETRISER PIPE
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
FHCLV
FHR
100Ø FIRE WETRISER PIPE
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHENTO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILETTO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILETTO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILETTO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILETTO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILETTO TOILET
TO TOILET
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
TO KITCHEN
15-16
8'-9'E''-F''
3'-4'F''-H''
8'-11'H''-I'' I''-K''
3'-4'K''-L''
7'-9'M''-O''
7'-10'Q''-R''
6'-8'Q''-R''
1'-2'T''-V''
8'-11'B.F.V
B.F.V
T.O.W T.O.WT.O.W
CAP.=25KL.
DOMESTIC
CAP.=20KL.
O.H FIRE WATER TANK WATER TANK
80Ø F.W.S 100Ø D.W.S
FILLING PIPE FROM S.T.P32Ø F.W.S O.H TANK
FLUSHING
CAP.=10KL.
O.H
WATER TANK
W-Y
11-12U-V
9-11T-U
10-11Q-R
13-14N-O
7-10M-N
13-14L-M
10-11H-I
10-11E-F
TO TOILETTO TOILET TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
TO KITCHENTO KITCHEN
11-12D-E
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
TO TOILET
7-10L-M
15-16A-C
1-2P1-R1
1-2G1-I1
FILLING PIPE FROM PUMP ROOM40Ø D.W.S O.H TANK
40Ø D.W.S O.H TANK 32Ø F.W.S O.H TANK
REFE
RENC
E LIN
ERE
FERE
NCE
LINE
LEGEND FOR PLUMBINGDOMESTIC WATER SUPPLY D.W.SFLUSHING WATER SUPPLY F.W.SGALVANIZED IRONG.I
DOMESTIC WATER SUPPLY PIPEFLUSHING WATER SUPPLY PIPEDOMESTIC WATER SUPPLY O.H WATER TANK FILLING PIPEFLUSHING WATER SUPPLY O.H WATER TANK FILLING PIPE
BALL VALVEB.VBUTTER FLY VALVEB.F.VNON-RETURN VALVEN.R.V
FIRE WETRISER PIPE
DOMESTIC WATER TANK
65Ø OVER FLOW PIPEFIRE WATER TANK TO
B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V B.F.V
150Ø FIRE PIPE
2 WAY FIRE BRIGADE INLET CONNECTION
LANDING VALVELVFIRE HOSE REELFHRFIRE HOSE CABINETFHC
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
TO TOILETTO TOILET
* ALL VALVE 50mm DIA & ABOVE SHALL BE BUTTER FLY VALVE.
FILLING PIPE FROM PUMP ROOM40Ø D.W.S O.H TANK FILLING PIPE FROM S.T.P32Ø F.W.S O.H TANK
40Ø D.W.S O.H TANK 32Ø F.W.S O.H TANK
B.F.V
B.F.V
AIR RELEASE
VALVEAIR RELEASE
DRG. TITLE
SCALE1:150DEALTHITESH
ARCHITECT:V A S T U N I D H IARCHITECT, PLANNER & INT. DESIGNERSB-135, SECTOR 44,NOIDAPHONE:2432190 FAX:4331407
PROJECT:
VILLAGE BHANKROTA, AJMER ROAD, JAIPUR
CLIENT:
208,OCEAN COMPLEX SEC-18,NOIDA
REV. NO.
DRG. NO.D'T(9)-PL-SYS-7
DATE12-03-2014
TOWER NO.
MAJESTIC PROPERTIES PVT.LTD.
WATER SUPPLY SYSTEM
TOWER NO. A
THIS DRAWING IS THE PROPERTY OF M/SVASTUNIDHI AND SHALL NOT BEREPRODUCED OR USED FOR ANYOTHER PURPOSE THAN SPECIFIEDWITHOUT WRITTEN PERMISSION
CHECKEDMAHENDRA
T17 ( G+8)
PRINT DATA:S.NO. DATE (PRINTS)ISSUED TO
REVISIONS:S.NO. REV.NO. PARTICULARS
NO.
NOTES:
N
LAVANYA
I-HOMES AND
DIAGRAM (PLUMBING)
KAKROLA ROAD NAJAFGARHNEW DELHI-110043PH:- [email protected]
1/30 ROSHAN GARDEN-IIARK CONSULTANTSPLUMBING CONSULTANTS