System Configuration Data SheetJanuary 202000806-0100-5100, Rev AC
Rosemount Tank Gauging System
System informationIn order to be able to correctly configure and assemble the parts of the system, the System Configuration Data Sheet must be filled in. It is also necessary to provide drawings of the tank farm layout with proposed location of level gauges, field displays, tank hubs, system hubs, field bus modems, Rosemount™ TankMaster etc.
NoteThe information on this form is used for tagging signs, temperature sensor specification and wireless network information only. No setting of device data base is done based on information on this data sheet.
Please state all distances in metric units.
System overview
Customer information
Rosemount Tank Gauging system number: ________________________ Installation site: _____________________________________________
Total number of tanks:_________________________________________ Year and month: _____________________________________________
End customer: _______________________________________________ Contact name: ______________________________________________
Telephone:__________________________________________________ P.O. Reference No: ___________________________________________
Customer sign-off:_________________________________________________________________________________________________________
Email address: ____________________________________________________________________________________________________________
SIL 2SIL 2
SIL 3
Rosemount 2230 Graphical Field Display
Rosemount 2410Tank Hub
Guided Wave RadarLevel Transmitter
Multi-input TemperatureTransmitter
Rosemount 565/566Multiple Spot Temperature Sensor
Liquid Level Switches
Rosemount 3051SPressure Transmitter
Radar Level Gauge (2-in-1 option)
Still-pipe Array Still-pipe ArrayHorn 2-in-1
SIL 2 / SIL 3
SIL 2
LPG/LNG LPG/LNGCone
Rosemount 5900CRadar Level Gauge Wireless Guided Wave
Radar Level TransmitterRadar LevelTransmitter
Rosemount 765Multiple Spot Temperature and Water Level Sensor
Parabolic Parabolic
22305900S 5900S2240S
3051S
644
5900S 2-in-1
5900S 2-in-1
2410
2410
2410
5900C 2240S
3051S
644
5408
5300
2410
2410 EmersonWireless1410/1420Gateway
TankMasterPC in Network
Alternative connection toDCS/PLC/SCADA/Host
Alternative connection toDCS/PLC/SCADA/Host
Alternative connection toDCS/PLC/SCADA/Host
TankMaster Net for Web Access
2460System Hub
2160 3308
Alarm
Emerson™Wireless775 THUM™ Adapter
Safety InstrumentedSystem (SIS)
Safety InstrumentedSystem (SIS)
Rosemount 644Temperature Transmitterwith 65, 114C or 214C Single PointTemperature Sensor
Rosemount RosemountRosemount
RosemountRosemount
Rosemount 5900S Rosemount 2240S Rosemount 2140/2160 Rosemount 5408 Rosemount 5300 Rosemount 3308
Rosemount
Rosemount2410Rosemount
www
January 2020Rosemount Tank Gauging System
2
Tank name Antenna type Tank product Tank height (mm)
Radar tag name
2410 hub tag name
2240 temp Tx tag name
2230 display tag name
Note
3
Rosemount Tank Gauging SystemJanuary 2020
Tag/Tank name L0 Temp sensor length include WLS (mm)
Position of temperature spot elements from sensor bottom end (mm)
T1 T2 T3 T4 T5 T6 T7 T8
T9 T10 T11 T12 T13 T14 T15 T16
T1 T2 T3 T4 T5 T6 T7 T8
T9 T10 T11 T12 T13 T14 T15 T16
T1 T2 T3 T4 T5 T6 T7 T8
T9 T10 T11 T12 T13 T14 T15 T16
T1 T2 T3 T4 T5 T6 T7 T8
T9 T10 T11 T12 T13 T14 T15 T16
T1 T2 T3 T4 T5 T6 T7 T8
T9 T10 T11 T12 T13 T14 T15 T16
T1 T2 T3 T4 T5 T6 T7 T8
T9 T10 T11 T12 T13 T14 T15 T16
T1 T2 T3 T4 T5 T6 T7 T8
T9 T10 T11 T12 T13 T14 T15 T16
T1 T2 T3 T4 T5 T6 T7 T8
T9 T10 T11 T12 T13 T14 T15 T16
January 2020Rosemount Tank Gauging System
4
Rosemount 565 Multiple Spot Temperature Sensor Rosemount 566 Multiple Spot Temperature Sensor for Cryogenic Use (NL-Cryo)
L= Distance from nozzle top to tank bottom
LW = Height of weight
LT = Length of sensor in tank
L0 = Total length of sensor (LT + 350 mm)
Where:350 = Distance from top of sensor to middle of the thread (exact position of flange can be adjusted ± 125 mm (4.92 in.) mm at installation using the nuts and the 257 mm (10.1 in.) thread length
Lowest temperature spot (T1) 500 - 1000 mm (19.7 - 39.4 in.) above tank bottom, minimum 150 mm (5.9 in.) from eye bolt in end of sensor
Highest temperature spot 500 - 1000 mm (19.7 - 39.4 in.) below maximum level, minimum 1000 mm (39.4 in.) from top of sensor
L= Distance from nozzle top to tank bottom
LW = Height of weight
LT = Length of sensor in tank
L0 = Total length of sensor (LT + 350 mm)
Where:350 = Distance from top of sensor to bottom of flange
Lowest temperature spot (T1) 500 - 1000 mm (19.7 - 39.4 in.) above tank bottom, minimum 150 mm (5.9 in.) from eye bolt in end of sensor
Highest temperature spot 500 - 1000 mm (19.7 - 39.4 in.) below maximum level, minimum 1000 mm (39.4 in.) from top of sensor
Mod
el: 5
65M
1864
0AXX
YYPX
X00
Spot
pos
ition
s (m
m fr
om e
ye b
olt)
:1.
10.
T1
LWLTLL0
T2T3
Minimum 500 mm
Minimum 1000 mm
350
mm
Hig
hest
tem
pera
ture
ele
men
t <T1
6(1
3.8
in.)
(39.4 in.)
(19.7 in.)
Maximum Filling Level
Mod
el: 5
66M
1864
0AXX
YYPA
300
Spot
pos
ition
s (m
m fr
om e
ye b
olt)
:1.
10.
T1
LWLTLL0
T2T3
Minimum 500 mm
350
mm
Hig
hest
tem
pera
ture
ele
men
t <T1
6
Maximum Filling Level
(13.
8 in
.)
(19.7 in.)
5
Rosemount Tank Gauging SystemJanuary 2020
Rosemount 765 Multiple Spot Temperature Sensor with Water Level Sensor
L= Distance from nozzle top to tank bottom
LW = Height of weight
LT = Length of sensor in tank (including WLS)
L0 = Total length of sensor (LT + 350 mm)
Where:350 = Distance from top of sensor to middle of the thread (exact position of flange can be adjusted ± 125 mm (4.92 in.) mm at installation using the nuts and the 257 mm (10.1 in.) thread length
Lowest temperature spot (T1) 500 - 1000 mm (19.7 - 39.4 in.) above tank bottom, minimum 300 mm (11.8 in.) from eye bolt in end of WLS
Highest temperature spot 500 - 1000 mm (19.7 - 39.4 in.) below maximum level, minimum 1000 mm (39.4 in.) from top of sensor
T1
LWLTLL0
T2T3
Min
imum
150
mm
Minimum 500 mm
Minimum 1000 mm
350
mm
Hig
hest
tem
pera
ture
ele
men
t <T1
6
(13.
8 in
.)
(39.4 in.)
(19.7 in.)
(5.9
in.)
Maximum Filling Level
January 2020Rosemount Tank Gauging System
6
Wireless network design (if included)
For more help on pre-planning of a Tank Gauging Wireless network see the Rosemount Tank Gauging Wireless System Reference Manual (document number 00809-0100-5200). Tools to be used are a scaled sketch of the installation site and AMS Wireless SNAP-ON™ Software.
Rule of 5 Found to be OK: Comments: __________________________________________________________________________________________
__________________________________________________________________________________________________________________________________________
__________________________________________________________________________________________________________________________________________
Rule of 3 Found to be OK: Comments:________________________________________________________________________________________
__________________________________________________________________________________________________________________________________________
__________________________________________________________________________________________________________________________________________
Rule of 25% Found to be OK: Comments:________________________________________________________________________________________
__________________________________________________________________________________________________________________________________________
__________________________________________________________________________________________________________________________________________
Make a small sketch of the planned Wireless Network or send a copy of the SNAP-ON design picture
Global Headquarters and Europe Regional Office Tank GaugingEmerson Automation SolutionsBox 150(Visiting address: Layoutvägen 1)SE-435 23 MölnlyckeSweden
+46 31 337 00 00+46 31 25 30 22 [email protected]
North America Regional OfficeTank GaugingEmerson Automation Solutions 6005 Rogerdale RoadMail Stop NC 136Houston, TX 77072, USA
+1 281 988 4000 or +1 800 722 [email protected]
Latin America Regional OfficeEmerson Automation Solutions 1300 Concord Terrace, Suite 400Sunrise, FL 33323, USA
+1 954 846 5030+1 954 846 [email protected]
Asia Pacific Regional OfficeEmerson Automation Solutions1 Pandan CrescentSingapore 128461
+65 6777 8211+65 6777 0947 [email protected]
Middle East and Africa Regional OfficeEmerson Automation Solutions Emerson FZE P.O. Box 17033Jebel Ali Free Zone - South 2Dubai, United Arab Emirates
+971 4 8118100+971 4 8865465 [email protected]
Linkedin.com/company/Emerson-Automation-Solutions
Twitter.com/Rosemount_News
Facebook.com/Rosemount
Youtube.com/user/RosemountMeasurement
Emerson Terms and Conditions of Sale are available upon request.The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners.© 2020 Emerson. All rights reserved.
System Configuration Data SheetJanuary 2020
Rosemount Tank Gauging System00806-0100-5100, Rev AC