system description acrowall-es - basf · 2018. 11. 6. · kick-out flashing detail system...
TRANSCRIPT
![Page 1: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes](https://reader035.vdocuments.site/reader035/viewer/2022071102/5fdc11f3dd9817723842e7aa/html5/thumbnails/1.jpg)
Acrowall-ESClass PB EIFS incorporating a primary moisture barrier
Typical Details
1. ACROWALL-ES SYSTEM APPLICATION (PLAN VIEW)
2. ACROWALL-ES SYSTEM APPLICATION (ISOMETRIC VIEW)
3. AESTHETIC GROOVE (PLAN VIEW)
4. INSULATION BOARDS/REINFORCING MESH APPLICATION AT OPENINGS
5. WINDOW HEAD (FLUSH)
6. WINDOW HEAD (RECESSED)
7. WINDOW JAMB (FLUSH) (PLAN VIEW)
8. WINDOW JAMB (RECESSED) (PLAN VIEW)
9. WINDOW SILL (FLUSH)
10. WINDOW SILL (RECESSED)
11. ROOF EDGE FLASHING
12. METAL COPING
13. PARAPET EPS CAP DETAIL
14. EXPANSION JOINT DETAIL AT FLOORLINE OF WOOD FRAME CONSTRUCTION
15. EXPANSION JOINT AT CHANGE IN SUBSTRATE
16. TERMINATION AT SOFFIT/GABLE END
17. EXPANSION JOINT DETAIL (PLAN VIEW)
18. PIPE PENETRATION
19. CORNER MESH APPLICATION WITH HI-IMPACT 20 (PLAN VIEW)
20. CORNER MESH APPLICATION WITH ACROMESHTM 4, INTERMEDIATE 6 OR 12 (PLAN VIEW)
21. LIGHT FIXTURE
22. TERMINATION AT FOUNDATION
23. TERMINATION AT FOUNDATION (FLUSH)
24. KICK-OUT FLASHING DETAIL
SYSTEM DESCRIPTION1033763
![Page 2: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes](https://reader035.vdocuments.site/reader035/viewer/2022071102/5fdc11f3dd9817723842e7aa/html5/thumbnails/2.jpg)
NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others
ACROWALL-ES DETAILS
FRAMING
ACCEPTABLE SHEATHING
ACROCRETE® BASE COAT
ACROCRETE INSULATION BOARD
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
2. TYPICAL ACROWALL-ES SYSTEM APPLICATION (ISOMETRIC VIEW)
1. TYPICAL ACROWALL-ES SYSTEM APPLICATION (PLAN VIEW)
FRAMING
ACCEPTABLE SHEATHING
ACROCRETE® BASE COAT
ACROCRETE INSULATION BOARD
ACROCRETE BASE COAT
ACROCRETE REINFORCING MESH
ACROCRETE FINISH COAT
![Page 3: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes](https://reader035.vdocuments.site/reader035/viewer/2022071102/5fdc11f3dd9817723842e7aa/html5/thumbnails/3.jpg)
NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others
4. TYPICAL INSULATION BOARDS/REINFORCING MESH APPLICATION AT OPENINGS
3. TYPICAL AESTHETIC GROOVE (PLAN VIEW)
FRAMING
ACCEPTABLE SHEATHING
ACROCRETE® BASE COAT
AESTHETIC GROOVE
ACROCRETE® INSULATION BOARD
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
ACROCRETE INSULATION BOARD
STAGGER INSULATION BOARD JOINTS AT CORNER OF OPENINGS
WRAP ACROCRETE BASE COAT AND ACROMESHTM 4 WRAP ACROCRETE BASE COAT AND ACROMESHTM 4 REINFORCING MESH AT INSULATION BOARD EDGESREINFORCING MESH AT INSULATION BOARD EDGES
ACROMESH 4 REINFORCING MESHEMBEDDED IN ACROCRETE BASE COATEMBEDDED IN ACROCRETE BASE COAT
NOTE: • TYPICAL AT WINDOWS, DOORS, ETC.• MAINTAIN A MIN. 13 MM (1/2”) PERIMETER SEALANT JOINT• FLASHINGS ARE BY OTHERS AND SHALL BE AS PER DESIGN/CODE REQUIREMENTS• FLASHINGS ARE BY OTHERS AND SHALL BE AS PER DESIGN/CODE REQUIREMENTS
305 M
M (12”
)
305 M
M (12”
)
229 MM (9”)
229 MM (9”)
![Page 4: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes](https://reader035.vdocuments.site/reader035/viewer/2022071102/5fdc11f3dd9817723842e7aa/html5/thumbnails/4.jpg)
NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others
ACROWALL-ES DETAILS
FRAMING
ACCEPTABLE SHEATHING
ACROCRETE® BASE COAT
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
WRAP BASE COAT AND ACROCRETE REINFORCING MESH
ACROCOTE® T
BACKER ROD AND SEALANT
WINDOW
6. TYPICAL WINDOW HEAD (RECESSED)
5. TYPICAL WINDOW HEAD (FLUSH)
FRAMING
ACCEPTABLE SHEATHING
ACROCRETE® BASE COAT
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
WRAP BASE COAT AND ACROCRETE REINFORCING MESH
ACROCOTE® T
BACKER ROD AND SEALANT
WINDOW
![Page 5: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes](https://reader035.vdocuments.site/reader035/viewer/2022071102/5fdc11f3dd9817723842e7aa/html5/thumbnails/5.jpg)
NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others
FRAMING
ACCEPTABLE SHEATHING
ACROCRETE® BASE COAT
ACROCRETE INSULATION BOARD
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
WRAP BASE COAT AND ACROCRETE REINFORCING MESH
ACROCOTE® T
BACKER ROD AND SEALANT
WINDOW
8. TYPICAL WINDOW JAMB DETAIL (RECESSED) (PLAN VIEW)
7. TYPICAL WINDOW JAMB DETAIL (FLUSH) (PLAN VIEW)
FRAMING
ACCEPTABLE SHEATHING
ACROCRETE® BASE COAT
ACROCRETE INSULATION BOARD
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
WRAP BASE COAT AND ACROCRETE REINFORCING MESH
ACROCOTE® T
BACKER ROD AND SEALANT
WINDOW
![Page 6: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes](https://reader035.vdocuments.site/reader035/viewer/2022071102/5fdc11f3dd9817723842e7aa/html5/thumbnails/6.jpg)
NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others
ACROWALL-ES DETAILS
WINDOW
BACKER ROD AND SEALANT
ACROCOTE® T
FRAMING
WRAP BASE COAT AND ACROCRETE® REINFORCING MESH
ACCEPTABLE SHEATHING
ACROCRETE BASE COAT
ACROCRETE INSULATION BOARD
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
10. TYPICAL WINDOW SILL DETAIL (RECESSED)
9. TYPICAL WINDOW SILL DETAIL (FLUSH)
WINDOWNOTE:• EXTEND FLASHING MIN. OF • 50 MM (2”) OVER EIFS• FLASHINGS ARE BY OTHERS • AND SHALL BE AS PER DESIGN/ • CODE REQUIREMENTS
PAN FLASHING
WRAP BASE COAT AND ACROCRETE® REINFORCING MESH
SEALANT
FRAMING
ACCEPTABLE SHEATHING
ACROCRETE BASE COAT
ACROCRETE INSULATION BOARD
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
![Page 7: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes](https://reader035.vdocuments.site/reader035/viewer/2022071102/5fdc11f3dd9817723842e7aa/html5/thumbnails/7.jpg)
NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others
12. TYPICAL METAL COPING DETAIL
11. TYPICAL ROOF EDGE FLASHING DETAIL
ROOF SYSTEM
ROOF EDGE FLASHING
SEALANT
WRAP BASE COAT AND ACROCRETE® REINFORCING MESH
FRAMING
ACCEPTABLE SHEATHING
ACROCRETE BASE COAT
ACROCRETE INSULATION BOARD
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
ROOF SYSTEM
ROOF EDGE FLASHING
SEALANT
WRAP BASE COAT AND ACROCRETE® REINFORCING MESH
FRAMING
ACCEPTABLE SHEATHING
ACROCRETE BASE COAT
ACROCRETE INSULATION BOARD
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
MIN. 50 MM (2”)
MIN. 50 MM (2”)
![Page 8: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes](https://reader035.vdocuments.site/reader035/viewer/2022071102/5fdc11f3dd9817723842e7aa/html5/thumbnails/8.jpg)
NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others
ACROWALL-ES DETAILS
14. TYPICAL EXPANSION JOINT DETAIL AT FLOORLINE WOOD-FRAME CONSTRUCTION
13. TYPICAL EPS PARAPET CAP DETAIL
NOTEFLASHINGS ARE BY OTHERS AND SHALL BE AS PER DESIGN/CODE REQUIREMENTS.
EPS CAP
FRAMING
WRAP BASE COAT AND ACROCRETE® REINFORCING MESH
ACCEPTABLE SHEATHING
ACROCRETE BASE COAT
ACROCRETE INSULATION BOARD
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
ROOF SYSTEM
TYPICAL WOOD FRAMING
ACCEPTABLE SHEATHING
BACKER ROD AND SEALANT
ACROCOTE® T
WRAP BASE COAT AND ACROCRETE REINFORCING MESH
ACROCRETE® BASE COAT
ACROCRETE INSULATION BOARD
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
MIN. 19 MM (3/4”)
![Page 9: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes](https://reader035.vdocuments.site/reader035/viewer/2022071102/5fdc11f3dd9817723842e7aa/html5/thumbnails/9.jpg)
NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others
16. TYPICAL TERMINATION AT SOFFIT/GABLE END
15. TYPICAL EXPANSION JOINT AT CHANGE IN SUBSTRATE
FRAMING
MASONRY
ACCEPTABLE SHEATHING
WRAP BASE COAT AND ACROCRETE® REINFORCING MESH
BACKER ROD AND SEALANTNOTE:JOINT WIDTH PER DESIGN
ACROCOTE® T
WRAP BASE COAT AND ACROCRETE REINFORCING MESH
ACROCRETE BASE COAT
ACROCRETE INSULATION BOARD
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
FRAMING
ACCEPTABLE SHEATHING
BLOCKING
SOFFIT
TRIM
FRIEZE BOARD
ACROCRETE INSULATION BOARD
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
MIN. 50 MM (2”)MIN. 50 MM (2”)
WRAP BASE COAT AND ACROCRETE REINFORCING MESH
ACROCRETE BASE COAT
![Page 10: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes](https://reader035.vdocuments.site/reader035/viewer/2022071102/5fdc11f3dd9817723842e7aa/html5/thumbnails/10.jpg)
NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others
ACROWALL-ES DETAILS
18. TYPICAL PIPE PENETRATION
17. TYPICAL EXPANSION JOINT DETAIL (PLAN VIEW)
FRAMING
ACCEPTABLE SHEATHING
ACROCOTE® T
BACKER ROD AND SEALANT
WRAP BASE COAT AND ACROCRETE® REINFORCING MESH
ACROCRETE BASE COAT
ACROCRETE INSULATION BOARD
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
TYPICAL WOOD FRAMING
ACCEPTABLE SHEATHING
WRAP BASE COAT AND ACROCRETE REINFORCING MESH
ACROCRETE INSULATION BOARD
BACKER ROD AND SEALANT
ACROCOTE T
ACROCRETE BASE COAT
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
MIN. 13 MM (1/2”) MIN. 13 MM (1/2”)
WIDTH PER DESIGN
![Page 11: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes](https://reader035.vdocuments.site/reader035/viewer/2022071102/5fdc11f3dd9817723842e7aa/html5/thumbnails/11.jpg)
NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others
20. TYPICAL CORNER MESH APPLICATION WITH ACROMESH 4, INTERMEDIATE 6 OR 12 (PLAN VIEW)
19. TYPICAL CORNER MESH APPLICATION WITH HI-IMPACT 20 (PLAN VIEW)
FRAMING
ACCEPTABLE SHEATHING
ACROCRETE® BASE COAT
ACROCRETE INSULATION BOARD
HI-IMPACT 20 EMBEDDED IN ACROCRETE BASE COAT
ACROMESHTM 4 OR INTERMEDIATE 6 EMBEDDED IN ACROCRETE BASE COAT
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
CORNER MESH EMBEDDED IN BASE COAT
FRAMING
ACCEPTABLE SHEATHING
ACROCRETE BASE COAT
ACROCRETE INSULATION BOARD
ACROMESH 4, INTERMEDIATE 6 OR 12 EMBEDDED IN ACROCRETE BASE COAT
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
CORNER MESH EMBEDDED IN BASE COAT
NOTE: A CONTINUOUS OVERLAY OF ACROMESH 4, INTERMEDIATE 6 OR 12 IS REQUIRED OVER CORNER MESH
NOTE: • BUTT EDGE OF HI-IMPACT 20 TO CORNER MESH• A CONTINUOUS OVERLAY • OF ACROMESH 4 OR • INTERMEDIATE 6 IS REQUIRED OVER HI-IMPACT 20 OR • CORNER MESH
![Page 12: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes](https://reader035.vdocuments.site/reader035/viewer/2022071102/5fdc11f3dd9817723842e7aa/html5/thumbnails/12.jpg)
NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others
ACROWALL-ES DETAILS
22. TYPICAL TERMINATION AT FOUNDATION
21. TYPICAL LIGHT FIXTURE
ACROCRETE INSULATION BOARD
FRAMING
ACCEPTABLE SHEATHING
WRAP BASE COAT AND ACROCRETE® REINFORCING MESH
SET FLANGE IN SEALANT
SMALL LIGHT FIXTURE
ACROCRETE BASE COAT
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
FRAMING
ACCEPTABLE SHEATHING
ACROCRETE BASE COAT
ACROCRETE INSULATION BOARD
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
WRAP BASE COAT AND ACROCRETE REINFORCING MESH
SEALANT AND BOND BREAKER
NOTE: • GRADE SHALL BE PITCHED • FOR POSITIVE DRAINAGE• TERMINATE SYSTEM 203 MM (8”) • MIN. ABOVE GRADE
WIRE OPENINGWIRE OPENING
MIN. 50 MM (2”)MAX. 305 MM (12”)
![Page 13: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes](https://reader035.vdocuments.site/reader035/viewer/2022071102/5fdc11f3dd9817723842e7aa/html5/thumbnails/13.jpg)
NOTE: Framing, acceptable sheathing NOTE: Framing, acceptable sheathing NOTE:and sealant by others
24. TYPICAL KICK-OUT FLASHING DETAIL
23. TYPICAL TERMINATION AT FOUNDATION (FLUSH)
FRAMING
ACCEPTABLE SHEATHING
ACROCRETE® BASE COAT
ACROCRETE INSULATION BOARD
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
WRAP BASE COAT AND ACROCRETE REINFORCING MESH
ACROCOTE® T
BACKER ROD AND SEALANT
FOUNDATION
ACCEPTABLE SHEATHING
STEP FLASHING
ACROWALL-ES SYSTEM
BACKER ROD AND SEALANT
ACROCRETE LAMINA:• ACROCRETE BASE COAT• ACROCRETE REINFORCING MESH• ACROCRETE FINISH COAT
MIN. 25 MM (1”)
NOTE:• KICK-OUT FLASHING MUST BE ANGLED 100˚ MIN. TO ALLOW FOR PROPER DRAINAGE.
• KICK-OUT FLASHING SEAMS MUST BE • KICK-OUT FLASHING SEAMS MUST BE SOLDERED OR SEALED WITH SOLDERED OR SEALED WITH APPROPRIATE SEALANT.
• TERMINATE ACROWALL-ES SYSTEM • TERMINATE ACROWALL-ES SYSTEM MIN. 50 MM (2”) ABOVE ROOF. MIN. 50 MM (2”) ABOVE ROOF.
BUILDING PAPERBUILDING PAPER
ROOF SHINGLESROOF SHINGLES
DRIP EDGE
KICK-OUT FLASHINGKICK-OUT FLASHING
MIN. 13 MM (1/2”)
![Page 14: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes](https://reader035.vdocuments.site/reader035/viewer/2022071102/5fdc11f3dd9817723842e7aa/html5/thumbnails/14.jpg)
NOTES
![Page 15: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes](https://reader035.vdocuments.site/reader035/viewer/2022071102/5fdc11f3dd9817723842e7aa/html5/thumbnails/15.jpg)
NOTES
![Page 16: SYSTEM DESCRIPTION Acrowall-ES - BASF · 2018. 11. 6. · KICK-OUT FLASHING DETAIL SYSTEM DESCRIPTION 1033763. NOTE: Framing, ... that the wall system selected be one that includes](https://reader035.vdocuments.site/reader035/viewer/2022071102/5fdc11f3dd9817723842e7aa/html5/thumbnails/16.jpg)
RESIDENTIAL POLICYOn one and two-family residential framed construction, BASF Wall Systems requires that the wall system selected be one that includes provisions for management of incidental moisture. The choices include water-managed EIFS, Acrowall-CP, and Acrowall-CBS. Acrowall Surfacing Systems for insulating concrete forms are also acceptable. There are no exceptions to this policy. Under no circumstances will BASF Wall Systems warrant the use of any other system on this type of construction with-out expressed written permission from BASF Wall Systems [Residential construction using EIFS on masonry (CMU) or poured concrete does not require the additional water management provisions described above.]
Consult BASF Wall Systems’ Technical Services Department for specific recom-mendations concerning all other applications. Consult the Acrocrete web-site, www.acrocrete.com for additional information about products and systems and for updated literature.
DISCLAIMERThis information and all further technical advice are based on BASF’s present knowledge and experience. However, BASF assumes no liability for providing such information and advice including the extent to which such information and advice may relate to existing third party intellectual property rights, especially patent rights. In particular, BASF disclaims all CONDITIONS AND WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY. BASF SHALL NOT BE RESPON-SIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. BASF reserves the right to make any changes according to technological progress or further developments. It is the customer’s responsibility and obligation to carefully inspect and test any incoming goods. Performance of the product(s) described herein should be verified by testing and carried out only by qualified experts. It is the sole responsibility of the customer to carry out and arrange for any such testing. Reference to trade names used by other companies is neither a recommendation, nor an endorsement of any product and does not imply that similar products could not be used.
BASF Wall Systems | 3550 St. Johns Bluff Road South Jacksonville, FL 32224-2614 P: 800.221.9255 F: 904. 996.6300 www.acrocrete.com©2006 BASF Printed in U.S.A. 11/06