system bm6 - polyglass - bm6.1 - eng... · 2017. 10. 22. · system bm6.1 green roof with...

1
Growing substrate POLYDREN PP 200 Gravel Protective screed in reinforced or fiber concrete ANTIRADICE P LIGHT 4 mm + MAPEPLAN PE macro-perforated + MAPEPLAN PE micro-perforated POLYFLEX LIGHT PUR VB IDROPRIMER + POLYVAP FIX AL Reinforced concrete slab Growing substrate POLYDREN PP 200 Woven-non-woven geotextile Gravel Protective screed in reinforced or fiber concrete ANTIRADICE P LIGHT 4 mm + MAPEPLAN PE macro-perforated + MAPEPLAN PE micro-perforated Waterproofing bituminous membrane - Reoxthene technology + macro-perforated sheet in LDPE + micro-perforated sheet in LDPE POLYFLEX LIGHT Waterproofing bituminous membrane - Reoxthene technology PUR VB Thermo-insulating panel made by expanded polyurethane with upper and bottom faces covered by with a bituminized glass veil IDROPRIMER + POLYVAP FIX AL Water-based bituminous primer + Bituminous vapour barrier with torch-on surface for bonding of insulation panels Reinforced concrete slab Build-up composition LAYER MATERIAL THICKNESS [mm] POSSIBLE ALTERNATIVE (*) Apply the product according to the thickness specified in the table. In the layout designed using Autodesk Revit software, the same product has been integrated into the next layer because the minimum representable thickness is 0.8 mm. For information on the characteristics and how to use the aforementioned products, please refer to the latest version of the relative Technical Data Sheets which are available on our website www.polyglass.com. Please note that it is the user’s responsibility to verify the accuracy of the values supplied by Revit for composite packages and, in all cases, Polyglass only guarantees the accuracy of the data and figures for materials/products manufactured by Polyglass. NO NOTE System BM6.1 Green roof with bituminous waterproofing membrane (insulated) System BM6.1 Green roof with bituminous waterproofing membrane (insulated) 7-2017 Structure 1 Reinforced concrete slab Concrete and masonry slab, precast concrete elements, corrugated metal sheet with concrete slab Bituminous primer (*) 2 IDROPRIMER POLYPRIMER HP 45 Pro Vapour barrier layer 3 POLYVAP FIX AL 3,5 mm POLYVAP RADONSHIELD 3 mm 0,1 3,5 Section Substrate with adequate slope Thermal insulation layer 4 PUR VB PUR/PIR according to EN 13165 with bituminous coating Waterproofing membrane first layer 5 POLYFLEX LIGHT 4 mm 6 ANTIRADICE P LIGHT 4 mm 30 40 50 60 70 80 100 120 140 160 4 Panels must be bonded Separation layers (*) 7 MAPEPLAN PE macro-perforated + MAPEPLAN PE micro-perforated Protective screed 8 Protective screed in reinforced or fiber concrete Drainage layer 9 Gravel Expanded clay, geocomposite drainages 0,15 + 0,1 Waterproofing membrane second layer (anti-root) 4 Filter layer 10 POLYDREN PP 200 Soil 11 Growing substrate 2

Upload: others

Post on 31-Dec-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: System BM6 - polyglass - BM6.1 - ENG... · 2017. 10. 22. · System BM6.1 Green roof with bituminous waterproofing membrane (insulated) 7-2017 1 Structure Reinforced concrete slab

Growing substrate

POLYDREN PP 200

Gravel

Protective screed in reinforced or fiber concrete

ANTIRADICE P LIGHT 4 mm + MAPEPLAN PEmacro-perforated + MAPEPLAN PE micro-perforated

POLYFLEX LIGHT

PUR VB

IDROPRIMER + POLYVAP FIX AL

Reinforced concrete slab

Growing substrate

POLYDREN PP 200Woven-non-woven geotextile

Gravel

Protective screed in reinforced or fiber concrete

ANTIRADICE P LIGHT 4 mm + MAPEPLAN PEmacro-perforated + MAPEPLAN PE micro-perforatedWaterproofing bituminous membrane - Reoxthene technology +macro-perforated sheet in LDPE + micro-perforated sheet inLDPE

POLYFLEX LIGHTWaterproofing bituminous membrane - Reoxthene technology

PUR VBThermo-insulating panel made by expanded polyurethane withupper and bottom faces covered by with a bituminized glass veil

IDROPRIMER + POLYVAP FIX ALWater-based bituminous primer + Bituminous vapour barrier withtorch-on surface for bonding of insulation panels

Reinforced concrete slab

Build-up compositionLAYER MATERIALTHICKNESS

[mm]POSSIBLE ALTERNATIVE

(*) Apply the product according to the thickness specified in the table. In the layout designed using Autodesk Revitsoftware, the same product has been integrated into the next layer because the minimum representable thicknessis 0.8 mm.

For information on the characteristics and how to use the aforementioned products, please refer to the latest version ofthe relative Technical Data Sheets which are available on our website www.polyglass.com.

Please note that it is the user’s responsibility to verify the accuracy of the valuessupplied by Revit for composite packages and, in all cases, Polyglass onlyguarantees the accuracy of the data and figures for materials/productsmanufactured by Polyglass.

NO NOTE

System BM6.1Green roof with bituminous waterproofing membrane (insulated)

System BM6.1Green roof with bituminous waterproofing membrane(insulated)

7-2017

Structure1 Reinforced concrete slabConcrete and masonry slab, precastconcrete elements, corrugated metalsheet with concrete slab

Bituminous primer (*)2 IDROPRIMER POLYPRIMER HP 45 Pro

Vapour barrier layer3 POLYVAP FIX AL 3,5 mm POLYVAP RADONSHIELD 3 mm

0,1

3,5

Section

Substrate with adequate slope

Thermal insulation layer4 PUR VBPUR/PIR according to EN 13165with bituminous coating

Waterproofingmembranefirst layer

5 POLYFLEX LIGHT 4 mm

6 ANTIRADICE P LIGHT 4 mm

30 40 5060 70 80100 120140 160

4

Panels must be bonded

Separation layers (*)7MAPEPLAN PE macro-perforated +MAPEPLAN PE micro-perforated

Protective screed8Protective screed inreinforced or fiber concrete

Drainage layer9 Gravel Expanded clay, geocomposite drainages

0,15 + 0,1

Waterproofingmembranesecond layer (anti-root)

4

Filter layer10 POLYDREN PP 200

Soil11 Growing substrate

2