synchronization of rfid readers for dense rfid reader
DESCRIPTION
TRANSCRIPT
1
Synchronization of RFID Readers for Dense RFID Reader Environments
Alfio R. GrassoAuto-ID Lab @ Adelaide
School of Electrical & Electronic Engineering
University of AdelaideAustralia
2
AUTO-ID LABS
Main Author Kin Seong Leong (PhD Candidate)
Co-Authors Prof Peter Cole (PhD Supervisor) Ms Mun Leng Ng (PhD Candidate) Mr Alfio Grasso
3
AUTO-ID LABS User Requirements †
100’s to 1000’s of readers possible Industrial Parks 2 km radius 100’s readers per DC
DC → 50 -100 dock doors 2 readers per door
Cluster of DC in Industrial Parks
† User Requirements for European RFID Regulations at UHF 30 Nov 2005
4
AUTO-ID LABS
Challenges in Dense RFID Reader Environments
Performance Maximal coverage Minimal interference / data loss
Regulations Frequency Hopping Spread Spectrum
(USA) Listen Before Talk (Europe)
Standards EPCglobal C1G2
5
AUTO-ID LABS FCC Environment
FCC Part 15.247 UHF RFID Band (902 to 928 MHz)
4W EIRP 50 channels, 500 kHz wide
902.5 to 927.5 MHz Maximum dwell time 0.4 s (400 ms) Each channel used in 2.0 s interval
6
AUTO-ID LABS Listen Before Talk (LBT)
ETSI 302 208 865 to 868 MHz 200 kHz channels 2W ERP – only 10 channels LBT
Listen for 5 ms Various thresholds 2W ERP, threshold is -96 dBm
Use sub-band for 4s
7
AUTO-ID LABS LBT Threshold
-126 dBW = -96 dBm
8
AUTO-ID LABS EPCglobal C1G2
Dense Reader Mode (Annex G) Reader
Transmissions in even channels
Tag replies in odd channels
9
AUTO-ID LABS Deployment Problems
Distance between antennas, to be lower than -96 dBm threshold
Front
Back
Side
10
Proposed Solution Reader Synchronisation
11
AUTO-ID LABS
Reader SynchronizationThe Concept
Readers start to “Listen” at the same time and start to “Talk” at the same time.
12
AUTO-ID LABS Synchronisation Schemes
Not a subject of the paper, but could be Hardwired Network Controlled
NTP Protocol designed to synchronise the clocks of
computers over a network
Radio controlled Separate channel (use one of the 5 lower
powered channels) Master reader, issues synchronisation pattern
13
AUTO-ID LABS Case Study
Warehouse Depot in Europe ETSI EN 302 208
865 to 868 MHz 15 sub-bands, 200 kHz wide Only 10 sub-bands at 2W ERP
EPCglobal Class 1 Generation 2 Interrogator transmissions are located in even-
numbered channels Tag backscatter located in odd-numbered
channels
14
AUTO-ID LABS Combining EN302-208 and C1G2
Interrogators can use 5 of the channels for TransmissionIf all readers in a facility are networked and configured to listen at the same time, then at the end of the listen period, they can all synchronously startReaders will then naturally stay synchronised, within the sub-band
Even if different readers are on for different time, they will all start again in synchronism, once the last reader has finished.
Thus we can have several readers occupying the same channel, even if they are close together.
Readers assigned geographically to 1 of 5 sub-bands
15
AUTO-ID LABS Dock Door Example
The next slide depicts 6 dock doors, with each door requiring 2 readersEach reader is networked, and connected to some synchronisation deviceEach reader is assigned to operate in one of the 5 even numbered sub-bandsEach reader listens for the required time, and if the sub-band is free, starts TransmissionsEach transmission must terminate within 4 seconds, after which the reader releases the sub-band for at least 100 ms
16
Sub-band 2
Sub-band 4
Sub-band 6
Sub-band 8
Sub-band 10
17
AUTO-ID LABS Other Mechanisms
Reducing the overall time for talking. While it is possible to talk for 4 seconds, readers and
applications should be configured to talk for only the time necessary to capture tag data.
Reducing the power output. While the maximum allowed 2W ERP can be useful in single
or small population reader environments, in dense reader populations this higher power may not be necessary.
Use of external sensors. The sensor determines that an object may be in the near
vicinity, to turn on (enable) an RFID reader.
The use of RF opaque or RF absorbing materialsDynamic Channel Assignments
18
AUTO-ID LABS
Example with sensorstruck 3 absent, so no RF
19
AUTO-ID LABS
RF Opaque / RF Absorbing Materials
RF A b so rb in g M a te ria ls
2 8 4 1 0 6 2 8 4 1 0 6 2 8
20
AUTO-ID LABS
Switching Channel Assignments
C h a n n e l
8 2 6 1 0 4 8 2 6 1 0 4 8 2 C h a n n e l
2 8 4 1 0 6 2 8 4 1 0 6 2 8
21
AUTO-ID LABS Conclusions
Reader densities in Distribution Centres > 100’s
ETSI EN302-208 LBT @ -96 dBm Threshold
C1G2 Even channels for Tx => 5 sub bands
Synchronisation