Page 1: Switch to the Future of Fieldbus. Dart FieldbusDART Fieldbus, the latest addition to FieldConnex provides what many users have been asking for: The intrinsically safe High-Power Trunk

PROCESS AUTOMATIONPROCESS AUTOMATION

SWITCH TO THE FUTURE OF FIELDBUS

DART FIELDBUS

SWITCH TO THE FUTURE OF FIELDBUS

Page 2: Switch to the Future of Fieldbus. Dart FieldbusDART Fieldbus, the latest addition to FieldConnex provides what many users have been asking for: The intrinsically safe High-Power Trunk

THE INTRINSICALLy SAFE HIgH-POWER TRUNk

DART Fieldbus, the latest addition to FieldConnex provides what many users have been asking for: The intrinsically safe High-Power Trunk concept. DART Fieldbus overcomes the limitations of FISCO or Entity fieldbus systems and enables:

n Live working on trunk and devices allowed without hot work permitn Redundancy of power supplies with load sharingn Longer cable runs and more devicesn Reduced requirements for cabinet space

Dynamic Arc Recognition and Termination (DART) is recognized as a major innovation. However for planners and plant operators only few things change as DART is easy to understand, easy to engineer:

n A completely intrinsically safe installationn Reduced requirements for trainingn Simple validation without calculations

And most importantly: Spur connections for all intrinsically safe field instrumentation in gas group IIC.

DART protects the trunk. Compared to just limiting the power, DART detects and quenches a spark as it is occurring.

Complex technology, high availability, limited power – the challenges of instrumentation and control technology in the process industry can be overwhelming. But reliable solutions are available for any specific application with fieldbus systems such as FOUNDATION Fieldbus H1 and PROFIBUS PA. They are established worldwide particularly for the easy application of intrinsic safety. With DART Fieldbus, Pepperl+Fuchs provides a trend-setting technology that combines intrinsic safety with high power in one system. Fieldbus installation is as safe, available and powerful as never before – with full intrinsic safety.

THE WORkINg PRINCIPLE

This means that more power can be transmitted. And in case of a fault or disconnect, the spark – electrical energy transformed into heat – is limited to intrinsically safe levels.

As practically all sparks are of temporary nature, such as a disconnect operation of a Segment Protector the DART power supply will attempt to switch back on after only a few milliseconds.

During this very short interruption the Segment Protectors power the field instrumentation – the availability of communication and power supply is ensured.

More fundamental information and publications can be found on the website at: www.dart-fieldbus.com

Maximum Safety with Maximum Power. In Every Detail.

Page 3: Switch to the Future of Fieldbus. Dart FieldbusDART Fieldbus, the latest addition to FieldConnex provides what many users have been asking for: The intrinsically safe High-Power Trunk

APPLICATION AND COMPONENTS

DART SEgMENT PROTECTORDART POWER HUB

n Redundant power modules

n Output power 22.5 V/360 mA

n Optional Advanced Diagnostic Module for physical layer monitoring

n Up to 1000 m trunk length

The DART Segment Protector provides intrinsically safe outputs Ex ib. Any intrinsically safe instrument can be connected.

SySTEM COMPONENTS

THE POWERFUL yET INTRINSICALLy SAFE FIELDBUS SEgMENT

The DART Power Hub is based on the popular FieldConnex High-density Power Hub. It provides power to the segment and connections to the DCS system. It detects and switches off the spark.

n Protection from short- circuits at the spur

n Up to 4 Segment Protectors permitted per segment

n 12 outputs per Segment Protector

n Output 10.5...22.5 V/34 mA

All components and the system are certified according to IEC 60079-11 (ATEX and IECEx).

general Purpose Area/Zone 2Hazardous Area Zone 1

DCS

REDUNDANTDART POWERSUPPLy

THE INTRINSICALLy SAFE HIgH-POWER TRUNk PROTECTED By DART®

INTRINSICALLySAFE SPURS EX IB IIC

DART SEgMENT PROTECTORS

THE INTRINSICALLy SAFEHIgH-POWER TRUNk

n The safest fieldbus installationn More cable distancen High device countn Redundant power supplyn Certified for gas group IIC

Page 4: Switch to the Future of Fieldbus. Dart FieldbusDART Fieldbus, the latest addition to FieldConnex provides what many users have been asking for: The intrinsically safe High-Power Trunk

PROTECTING YOUR PROCESS

For over a half century, Pepperl+Fuchs has been continually providing new concepts for the world of process automation. Our company sets standards in quality and innovative technology. We develop, produce and distribute electronic interface modules, Human-Machine Interfaces and hazardous location protection equipment on a global scale, meeting the most deman-ding needs of industry. Resulting from our world-wide presence and our high flexibility in production and customer service, we are able to individually offer complete solutions – wherever and whenever you need us. We are the recognized experts in our technologies – Pepperl+Fuchs has earned a strong reputation by supplying the world’s largest process industry companies with the broadest line of proven components for a diverse range of applications.