sv100 open-loop vector vfd fv100 closed-loop vector vfd 1

18
SV100 SV100 Open-Loop Vector VFD Open-Loop Vector VFD FV100 FV100 Closed-Loop Vector Closed-Loop Vector VFD VFD 1

Upload: giovanna-roff

Post on 14-Dec-2015

236 views

Category:

Documents


2 download

TRANSCRIPT

SV100SV100 Open-Loop Vector VFD Open-Loop Vector VFD FV100FV100 Closed-Loop Vector VFD Closed-Loop Vector VFD

1

SV100/FV100SV100/FV100 Selection Guide Selection Guide SVSV//FVFV Series : Series :

Single Phase(220V): Single Phase(220V): 0.4K0.4KW~2.2KW; W~2.2KW; ThreeThree Phase(380V)Phase(380V): 0.4K: 0.4KW~W~40400KW. 0KW. CCV Series: Mini type, V Series: Mini type,

Single Phase(220V):0.4KSingle Phase(220V):0.4KW~W~1.51.5KWKW, Three Phase:1.5~2.2KW, Three Phase:1.5~2.2KW

2

Hardware InstructionHardware Instruction

3

Hardware StructureHardware Structure

4

All Series supports wall-mountedAll Series supports wall-mounted

5

Hardware Configuration(FV)Hardware Configuration(FV)

77 digital inputs digital inputs (( 11 high speed pulse input high speed pulse input)。)。 33 analog inputs analog inputs (( -10~10V-10~10V ;; 4~20mA4~20mA)。)。 22 digital ouputs digital ouputs。。 11 relay output relay output

6

Extensible Operation PadExtensible Operation Pad

7

RS485RS485 Communication Communication

RJ45 Cable

Control MethodControl Method

SV100SV100 :: V/FV/F,, Open-loopOpen-loop FV100FV100 :: V/FV/F,, Open-loop and closed-loopOpen-loop and closed-loop Support analog control: Support analog control: ±10V±10V//4~20mA4~20mA Communication ControlCommunication Control Digital Input ControlDigital Input Control Pulse ControlPulse Control (( FV100FV100))

8

Software InstructionSoftware Instruction

9

Main FunctionsMain Functions

10

Power on the Drive for the first time

After checking the wiring and power supply, power on the VFD, the VFD display “8.8..8.8.8”, then the relay is ON, when the LD displays the setting frequency , the VFD is initializes and starts successfully.

V/FV/F Control Control (( Key Pad ControlKey Pad Control ))

DefinitionDefinition :: V/FV/F is a constant , is a constant ,A0.01=2A0.01=2 Performance Parameters:Performance Parameters: 11:: Basic Operation Frequency Basic Operation Frequency FF :: A0.12A0.12 22:: External Input Voltage:External Input Voltage:VV 33:: Torque BoostTorque Boost :: A0.13A0.13 ,, b1.07b1.07 Operation ParametersOperation Parameters (( Key Pad SettingKey Pad Setting )) 11:: Main FrequencyMain Frequency :: A0.02=0A0.02=0 22:: Method of Operation CommandMethod of Operation Command :: A0.04=0A0.04=0 33:: Running DirectionRunning Direction :: A0.05:0A0.05:0:: ForwardForward ;; 11:: ReverseReverse 44:: Acc/Dec TimeAcc/Dec Time :: A0.06A0.06 ,, A0.07A0.07 55:: Start/Stop MethodStart/Stop Method:: Group A1Group A1

12

13

V/FV/F Control Control (( Analog ControlAnalog Control )) DefinitionDefinition :: V/FV/F is a constant . is a constant .A0.01=2A0.01=2 Performance Parameters:Performance Parameters: 11:: Basic Operation Frequency Basic Operation Frequency FF :: A0.12A0.12 22:: External Input Voltage:External Input Voltage:VV 33:: Torque BoostTorque Boost :: A0.13A0.13 ,, b1.07b1.07 Operation ParametersOperation Parameters (( Key Pad SettingKey Pad Setting )) 11:: Main FrequencyMain Frequency:::: A0.02=1A0.02=1,, 22:: Method of Operation CommandMethod of Operation Command :: A0.04=0A0.04=0(Key Pad)(Key Pad) ,, A0.04=1A0.04=1(Di(Di

gital Input)gital Input) :: XiXi setting , setting ,A6.00~A6.06A6.00~A6.06 33:: Running DirectionRunning Direction :: A0.05=0A0.05=0:: ForwardForward ;; 11:: ReverseReverse。。 44:: Acc/Dec TimeAcc/Dec Time :: A0.06A0.06 ,, A0.07A0.07 55:: Start/Stop MethodStart/Stop Method:: Group A1Group A1 6: Analog Setting: A3.00~A3.046: Analog Setting: A3.00~A3.04

14

V/FV/F Control Control (( Multi-SpeedMulti-Speed )) DefinitionDefinition :: V/FV/F is a constant . is a constant .A0.01=2A0.01=2 Performance Parameters:Performance Parameters: 11:: Basic Operation Frequency Basic Operation Frequency FF :: A0.12A0.12 22:: External Input Voltage:External Input Voltage:VV 33:: Torque BoostTorque Boost :: A0.13A0.13 ,, b1.07b1.07 Operation ParametersOperation Parameters (( Key Pad SettingKey Pad Setting )) 11:: Main FrequencyMain Frequency:::: A0.02=A0.02=0.0. 22:: Method of Operation CommandMethod of Operation Command :: A0.04=0A0.04=0(Key Pad)(Key Pad) ,, A0.04=1A0.04=1(Dig(Dig

ital Input)ital Input) :: XiXi setting , setting ,A6.00~A6.06A6.00~A6.06 33:: Running DirectionRunning Direction :: A0.05=0A0.05=0:: ForwardForward ;; 11:: ReverseReverse。。 44:: Acc/Dec TimeAcc/Dec Time :: A0.06A0.06 ,, A0.07A0.07 55:: Start/Stop MethodStart/Stop Method:: Group A1Group A1 66:: Multi-Frequency(Speed)Multi-Frequency(Speed):: Group Group C0C0

15

V/FV/F Control Control (( MainMain++Auxiliary FrequencyAuxiliary Frequency ))

DefinitionDefinition :: V/FV/F is a constant . is a constant .A0.01=2A0.01=2 Performance Parameters:Performance Parameters: 11:: Basic Operation Frequency Basic Operation Frequency FF :: A0.12A0.12 22:: External Input Voltage:External Input Voltage:VV 33:: Torque BoostTorque Boost :: A0.13A0.13 ,, b1.07b1.07 Operation ParametersOperation Parameters (( Key Pad SettingKey Pad Setting )) 11:: Main FrequencyMain Frequency:::: A0.02=A0.02=0.0. 22:: Method of Operation CommandMethod of Operation Command :: A0.04=0A0.04=0(Key Pad)(Key Pad) ,, A0.04=1A0.04=1(D(D

igital Input)igital Input) :: XiXi setting , setting ,A6.00~A6.06A6.00~A6.06 33:: Running DirectionRunning Direction :: A0.05=0A0.05=0:: ForwardForward ;; 11:: ReverseReverse。。 44:: Acc/Dec TimeAcc/Dec Time :: A0.06A0.06 ,, A0.07A0.07 55:: Start/Stop MethodStart/Stop Method:: Group A1Group A1 66 :: MainMain++Auxiliary Frequency:Auxiliary Frequency:A0.03+A2A0.03+A2

16

Open-Loop Vector Control IntroduceOpen-Loop Vector Control Introduce

DefinitionDefinition :: VFD caculate the current via PID,VFD caculate the current via PID,A0.01=0A0.01=0 Performance Parameters:Performance Parameters: 11:: Basic Operation Frequency Basic Operation Frequency FF :: A0.12A0.12 22:: External Input Voltage:External Input Voltage:VV 33:: Auto-tuningAuto-tuning:: set set b0.00b0.00 first first,, Then use the Then use the b0.11b0.11。。 44 :: PIDPID Parameters Parameters :: Group Group A5A5(( Speed Control, Analog ControlSpeed Control, Analog Control))

17

OutputsOutputs

Output ParametersOutput Parameters(( PulsePulse)) 11 :: A6.25A6.25 :: Y2Y2 Output Functions Output Functions 22 :: A6.26A6.26 ,, A6.27A6.27

Output ParametersOutput Parameters (( AO1 AO1 )) 11 :: A6.28A6.28 :: AO1AO1 Output Functions Output Functions 22 :: A6.30A6.30 ,, A6.31A6.31

18