s Maintenance SURPASS hiT 7020 3.2 Troubleshooting Manual A42022-L5966-B 57-1-7620

Upload: darko-duvnjak

Post on 28-Oct-2015

299 views

Category:

Documents


21 download

TRANSCRIPT

Page 1: SURPASS HiT 7020 Troubleshooting Manual 3p2

s

Maintenance

SURPASS hiT 7020 3.2

Troubleshooting Manual

A42022-L5966-B 57-1-7620

Page 2: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.1

Copyright (C) Siemens AG 2005

Issued by the Communications Group Hofmannstraße 51 D-81359 München

Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract.

2 A42022-L5966-B 57-1-7620

Important Notice on Product Safety Elevated voltages are inevitably present at specific points in this electrical equipment. Some of the parts may also have elevated operating temperatures. Systems with forced ventilation have rotating items.

Non-observance of these conditions and the safety instructions can result in personal injury or in property damage.

The system complies with the standard EN 60950-1 / IEC 60950-1. All equipment connected has to comply with the applicable safety standards.

Mount the systems in areas with restricted access only. Only trained and qualified personnel may install, operate, and maintain the systems.

The same text in German:

Wichtiger Hinweis zur Produktsicherheit

In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Spannung. Einige Teile können auch eine hohe Betriebstemperatur aufweisen. Anlagen mit Zwangsbelüftung haben drehende Teile.

Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverletzungen und Sachschäden führen.

Das System entspricht den Anforderungen der EN 60950-1 / IEC 60950-1. Angeschlossene Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.

Die Anlagen dürfen nur in Betriebsstätten mit beschränktem Zutritt aufgebaut werden. Die Anlagen dürfen nur durch geschultes und qualifiziertes Personal installiert, betrieben und gewartet werden.

Trademarks:

All designations used in this document can be trademarks, the use of which by third parties for their own purposes could violate the rights of their owners.

!!

Page 3: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 3

Contents

1 Notes on this Documentation .........................................................................................9 1.1 Customer Documentation...............................................................................................9 1.2 Complementary Documents ...........................................................................................9 1.3 Symbols Used in the Customer Documentation...........................................................10 1.3.1 Symbol for Warnings ....................................................................................................10 1.3.2 Symbols for Notes ........................................................................................................10 1.3.3 Symbols for Menu Displays and Text Inputs ................................................................10 1.4 Notes on Licensed Software.........................................................................................10 2 Protective Measures and Handling / Schutzmaßnahmen und Handhabung ...............11 2.1 Basic Remarks / Grundsätzliche Hinweise...................................................................11 2.2 Mechanical Design / Mechanische Konstruktion..........................................................12 2.2.1 Front Door of the Device / Geräte-Vordertür ................................................................12 2.2.2 Card Shieldings / Schirmungen der Baugruppen.........................................................12 2.3 Weight / Gewicht...........................................................................................................12 2.4 Temperature / Temperatur ...........................................................................................13 2.4.1 Device Cooling / Gerätekühlung...................................................................................13 2.4.2 Components Subject to High Operating Temperatures / Komponenten mit hoher

Betriebstemperatur .......................................................................................................13 2.5 Dust Filter / Staubfilter ..................................................................................................13 2.6 Grounding and Potential Balancing / Erdung und Potenzialausgleich........................14 2.7 Protection Against Excessive Overvoltage on the 48/60-Volts Power Supply Input /

Schutz gegen Überspannungen beim 48/60-Volt-Stromversorgungseingang............15 2.8 Electrostatic Sensitive Components (ESD) / Elektrostatisch gefährdete Bauteile (EGB)

......................................................................................................................................16 2.9 Fiber-optic Cables and Connectors / Lichtwellenleiter und optische Steckverbinder .17 2.10 Laser Radiation / Laserstrahlung..................................................................................18 2.10.1 Protection Against Extraneous Laser Light and Protection of the Optical Modules

Concerned / Schutz gegen austretendes Laserlicht und Schutz der betreffenden optischen Baugruppen..................................................................................................18

2.10.2 Laser Safety Circuit / Lasersicherheitsabschaltung .....................................................20 2.10.3 Handling Batteries / Handhabung von Batterien ..........................................................21 2.10.4 Emergency Switching OFF / Notabschaltung...............................................................22 3 Troubleshooting............................................................................................................23 3.1 Indicator and Control Elements on the hiT 7020 Network Elements............................23 3.1.1 LEDS ............................................................................................................................23 3.2 TNMS-M SURPASS hiT 7020 LCT Connection Description........................................23 3.2.1 IP Address Setting........................................................................................................23 3.2.2 Trap Destination Polling Mechanism............................................................................23 3.3 Alarm Evaluation and Fault Isolation............................................................................24 3.4 Fault Clearance Procedures.........................................................................................24 3.4.1 Cables and Connectors ................................................................................................24 3.4.2 Module Replacement....................................................................................................24 3.4.3 Special Fault Clearance ...............................................................................................25 4 Alarm Tables.................................................................................................................26 4.1 Format and Content of Alarm Tables ...........................................................................26 4.2 Alarm List......................................................................................................................27 4.2.1 AU-AIS..........................................................................................................................27 4.2.2 AU-LOP ........................................................................................................................28 4.2.3 E1-Negative_Bit-slip_TCA_15m...................................................................................29 4.2.4 E1-Negative_Bit-slip_TCA_24h....................................................................................30

Page 4: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

4 A42022-L5966-B 57-1-7620

4.2.5 E1-Positive_Bit-slip_TCA_15m ................................................................................... 31 4.2.6 E1-Positive_Bit-slip_TCA_24h .................................................................................... 32 4.2.7 Equipment_OverHeating ............................................................................................. 33 4.2.8 Excessive_Bad_Bytes_Received_TCA_1s (LAN or WAN)......................................... 34 4.2.9 Excessive_Bad_Packets_Received_TCA_1s (LAN/WAN) ......................................... 35 4.2.10 Fan_Failure.................................................................................................................. 36 4.2.11 HP-DEG....................................................................................................................... 37 4.2.12 HP-EXC ....................................................................................................................... 38 4.2.13 HP-FE_BBE_TCA_15m............................................................................................... 39 4.2.14 HP-FE_BBE_TCA_24h................................................................................................ 40 4.2.15 HP-FE_ES_TCA_15m................................................................................................. 41 4.2.16 HP-FE_ES_TCA_24h .................................................................................................. 42 4.2.17 HP-FE_SES_TCA_15m............................................................................................... 43 4.2.18 HP-FE_SES_TCA_24h................................................................................................ 44 4.2.19 HP-FE_UAS_TCA_15m .............................................................................................. 45 4.2.20 HP-FE_UAS_TCA_24h ............................................................................................... 46 4.2.21 HP-GFP_Customer_Signal_Failure ............................................................................ 47 4.2.22 HP-GFP_Loss_of_Frame_Delineation ........................................................................ 48 4.2.23 HP-NE_BBE_TCA_15m .............................................................................................. 49 4.2.24 HP-NE_BBE_TCA_24h ............................................................................................... 50 4.2.25 HP-NE_ES_TCA_15m................................................................................................. 51 4.2.26 HP-NE_ES_TCA_24h.................................................................................................. 52 4.2.27 HP-NE_SES_TCA_15m .............................................................................................. 53 4.2.28 HP-NE_SES_TCA_24h ............................................................................................... 54 4.2.29 HP-NE_UAS_TCA_15m.............................................................................................. 55 4.2.30 HP-NE_UAS_TCA_24h............................................................................................... 56 4.2.31 HP-RDI......................................................................................................................... 57 4.2.32 HP-PJCN_TCA_15m................................................................................................... 58 4.2.33 HP-PJCN_TCA_24h .................................................................................................... 59 4.2.34 HP-PJCP_TCA_15m ................................................................................................... 60 4.2.35 HP-PJCP_TCA_24h .................................................................................................... 61 4.2.36 HP-PLM ....................................................................................................................... 62 4.2.37 HP-TIM......................................................................................................................... 63 4.2.38 HP-UNEQ .................................................................................................................... 64 4.2.39 HP-Virtual_Connection_LOA....................................................................................... 65 4.2.40 HP-Virtual_Connection_LOM ...................................................................................... 66 4.2.41 Link_Failure ................................................................................................................. 67 4.2.42 Loss_of_Timing_Input ................................................................................................. 68 4.2.43 Loss_of_Timing_Output............................................................................................... 69 4.2.44 LP-DEG........................................................................................................................ 70 4.2.45 LP-EXC........................................................................................................................ 71 4.2.46 LP-FE_BBE_TCA_15m ............................................................................................... 72 4.2.47 LP-FE_BBE_TCA_24h ................................................................................................ 73 4.2.48 LP-FE_ES_TCA_15m.................................................................................................. 74 4.2.49 LP-FE_ES_TCA_24h................................................................................................... 75 4.2.50 LP-FE_SES_TCA_15m ............................................................................................... 76 4.2.51 LP-FE_SES_TCA_24h ................................................................................................ 77 4.2.52 LP-FE_UAS_TCA_15m............................................................................................... 78 4.2.53 LP-FE_UAS_TCA_24h................................................................................................ 79 4.2.54 LP-GFP_Customer_Signal_Failure ............................................................................. 80 4.2.55 LP-GFP_Loss_of_Frame_Delineation......................................................................... 81 4.2.56 LP-NE_BBE_TCA_15m............................................................................................... 82 4.2.57 LP-NE_BBE_TCA_24h................................................................................................ 83 4.2.58 LP-NE_ES_TCA_15m ................................................................................................. 84 4.2.59 LP-NE_ES_TCA_24h .................................................................................................. 85 4.2.60 LP-NE_SES_TCA_15m............................................................................................... 86 4.2.61 LP-NE_SES_TCA_24h................................................................................................ 87

Page 5: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 5

4.2.62 LP-NE_UAS_TCA_15m ...............................................................................................88 4.2.63 LP-NE_UAS_TCA_24h ................................................................................................89 4.2.64 LP-PLM.........................................................................................................................90 4.2.65 LP-RDI ..........................................................................................................................91 4.2.66 LP-RFI ..........................................................................................................................92 4.2.67 LP-TIM..........................................................................................................................93 4.2.68 LP-UNEQ......................................................................................................................94 4.2.69 LP-Virtual_Concatenation_LOA ...................................................................................95 4.2.70 LP-Virtual_Concatenation_LOM...................................................................................96 4.2.71 MS-AIS .........................................................................................................................97 4.2.72 MS-DCC_Connection_Failure ......................................................................................98 4.2.73 MS-DEG .......................................................................................................................99 4.2.74 MS-EXC......................................................................................................................100 4.2.75 MS-FE_BBE_TCA_15m.............................................................................................101 4.2.76 MS-FE_BBE_TCA_24h ..............................................................................................102 4.2.77 MS-FE_ES_TCA_15m ...............................................................................................103 4.2.78 MS-FE_ES_TCA_24h ................................................................................................104 4.2.79 MS-FE_SES_TCA_15m.............................................................................................105 4.2.80 MS-FE_SES_TCA_24h ..............................................................................................106 4.2.81 MS-FE_UAS_TCA_15m.............................................................................................107 4.2.82 MS-FE_UAS_TCA_24h..............................................................................................108 4.2.83 MS-K1/K2 Mismatch...................................................................................................109 4.2.84 MS-NE_BBE_TCA_15m.............................................................................................110 4.2.85 MS-NE_BBE_TCA_24h..............................................................................................111 4.2.86 MS-NE_ES_TCA_15m...............................................................................................112 4.2.87 MS-NE_ES_TCA_24h ................................................................................................113 4.2.88 MS-NE_SES_TCA_15m.............................................................................................114 4.2.89 MS-NE_SES_TCA_24h..............................................................................................115 4.2.90 MS-NE_UAS_TCA_15m ............................................................................................116 4.2.91 MS-NE_UAS_TCA_24h .............................................................................................117 4.2.92 MS-RDI .......................................................................................................................118 4.2.93 OA-Input_LOS ............................................................................................................119 4.2.94 OA-Output_LOS .........................................................................................................120 4.2.95 OA-Power_Failure ......................................................................................................121 4.2.96 OA-Pump_Bias_Out_Of_Range.................................................................................122 4.2.97 OA-Temperature_Bias_Out_Of_Range .....................................................................123 4.2.98 PPI-LOS......................................................................................................................124 4.2.99 RS-BBE_TCA_15m ....................................................................................................125 4.2.100 RS-BBE_TCA_24h .....................................................................................................126 4.2.101 RS-DCC_Connection_Failure ....................................................................................127 4.2.102 RS-DEG......................................................................................................................128 4.2.103 RS-ES_TCA_15m ......................................................................................................129 4.2.104 RS-ES_TCA_24h .......................................................................................................130 4.2.105 RS-EXC ......................................................................................................................131 4.2.106 RS-LOF.......................................................................................................................132 4.2.107 RS-SES_TCA_15m ....................................................................................................133 4.2.108 RS-SES_TCA_24h .....................................................................................................134 4.2.109 RS-UAS_TCA_15m....................................................................................................135 4.2.110 RS-UAS_TCA_24h.....................................................................................................136 4.2.111 RS-TIM .......................................................................................................................137 4.2.112 SFP_Failure................................................................................................................138 4.2.113 SFP_Mismatch ...........................................................................................................139 4.2.114 System_Clock_Unlocked............................................................................................140 4.2.115 SPI-LOS......................................................................................................................141 4.2.116 System_Clock_Holdover_Longer ...............................................................................142 4.2.117 Synchronization_Signal_Message_Mismatch............................................................143 4.2.118 TU-AIS ........................................................................................................................144

Page 6: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

6 A42022-L5966-B 57-1-7620

4.2.119 Timing_Reference_Degrade...................................................................................... 145 4.2.120 Timing_Reference_Failure ........................................................................................ 146 4.2.121 TU-LOM ..................................................................................................................... 147 4.2.122 TU-LOP...................................................................................................................... 148 4.2.123 Unit_Failure ............................................................................................................... 149 4.2.124 Unit_Removal ............................................................................................................ 150 4.2.125 UnitType_Mismatch ................................................................................................... 151 5 Abbreviations ............................................................................................................. 153

Page 7: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 7

Illustrations Fig. 3.1 Basic Options for Alarm Containment and Alarm Evaluation .....................................24

Page 8: SURPASS HiT 7020 Troubleshooting Manual 3p2
Page 9: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 9

1 Notes on this Documentation

1.1 Customer Documentation The Customer Documentation of the SURPASS hiT 7020 comprises the following descriptions and manuals:

• Technical Manual

The Technical Manual gives an overview of the application, performance features, interfaces and functions of the SURPASS hiT 7020. It also contains the most important technical data.

The Technical Manual does not contain any instructions to be carried out.

• Installation and Test Manual

The Installation and Test Manual contains instructions on mounting, connecting and commissioning the SURPASS hiT 7020, and connecting and commissioning the LCT operating terminals.

• Troubleshooting Manual The Troubleshooting Manual provides information about the alarm list SURPASS hiT 7020 supports and troubleshooting procedures.

• TNMS-M SURPASS hiT 7020 LCT User Manual The LCT User Manual provides information about the LCT (features, configuration, installation, etc.) and how to operate, monitor and maintain the SURPASS hiT 7020 using the Element Manager software (Application Software) running on the LCT.

Besides the LCT User Manual, the Online Help of the SURPASS hiT software is of high importance for the operator.

1.2 Complementary Documents In addition to the SURPASS hiT 7020 customer documentation listed in Chapter 1.1, there is further documentation: • SURPASS hiT 7020 Release Note

This document identifies the specific version of the SURPASS hiT 7020 and provides information on HW, SW, LCT components and the limitations of the release as well as important notes concerning the customer documentation.

ii

ii

Page 10: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

10 A42022-L5966-B 57-1-7620

1.3 Symbols Used in the Customer Documentation

1.3.1 Symbol for Warnings

This symbol identifies notes which, if ignored, can result in personal injury or in permanent damage to the equipment.

1.3.2 Symbols for Notes

Information which extends beyond the immediate context.

Cross reference to other chapters in this manual or reference to other manuals.

HELP Reference to the online help system of the Element Manager software.

1.3.3 Symbols for Menu Displays and Text Inputs Menu options from pop-up menus or inputs to be made by the user (texts, commands) are displayed consecutively in their hierarchical sequence in pointed brackets: <Menu> <Menu item> <Command text> <Parameter> etc.

1.4 Notes on Licensed Software This documentation refers to software products which were taken over from other companies as licenses. Should problems arise, you should contact Siemens AG as the licensee and not the relevant licenser.

!!

ii

Page 11: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 11

2 Protective Measures and Handling / Schutzmaßnahmen und Handhabung

2.1 Basic Remarks / Grundsätzliche Hinweise If the following rules are not observed, and if equipment damages or personnel injuries are the result, the manufacturer assumes no liability, and the warranty will expire!

Bei Nichtbeachtung der nachfolgenden Vorschriften und daraus resultieren- den Personen- oder Sachschäden wird keine Haftung seitens des Herstellers übernommen, und die Gewährleistung erlischt!

If you replace any parts of devices or ca-bles, you must only use original spare parts or parts which are explicitly licensed by the manufacturer.

Falls Sie an den Geräten oder an der Ver- kabelung irgendwelche Teile ersetzen, dann dürfen Sie nur Original-Ersatzteile oder solche Teile verwenden, die vom Hersteller ausdrücklich zugelassen sind.

Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equip-ment.

Änderungen oder Modifikationen, die vom Hersteller nicht ausdrücklich zugelassen wurden, können zum Erlöschen der allgemeinen Betriebsgenehmigung für das Gerät führen.

If necessary, safety signs and markings according to IEC 61310-1 are fixed to the devices.

Soweit notwendig, sind an den Geräten Sicherheitssymbole und Kennzeichnungen nach IEC 61310-1 angebracht.

Important Note: If no date is specified, the norms men-tioned in the following (EN, IEC, UL, etc.) refer to the latest issue of the respective norm in each case.

Wichtiger Hinweis: Wenn kein Datum angegeben ist, beziehen sich die Normen (EN, IEC, UL usw.), die im folgenden erwähnt werden, auf die jeweils neueste Ausgabe der entsprechenden Norm.

Additional (more specific) safety re-marks may also be included in the following main chapters of this.

Zusätzliche (speziellere) Sicher-heitshinweise können auch in den nachfolgenden Hauptkapiteln dieses Handbuches enthalten sein.

!!

!!

!!

ii

Page 12: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

12 A42022-L5966-B 57-1-7620

2.2 Mechanical Design / Mechanische Konstruktion

2.2.1 Front Door of the Device / Geräte-Vordertür A subrack being fitted with a front door must only be operated with this door closed. There is danger of personal injury, if the door of the subrack is open.

Baugruppenträger, die eine Vordertür haben, dürfen nur betrieben werden, wenn diese Tür geschlossen ist. Bei geöffneter Vordertür des Baugruppenträgers besteht Verletzungsgefahr.

For this reason, before working on the subrack, open the front door, raise it and then remove it.

Öffnen Sie deshalb, bevor Sie am Baugruppenträger arbeiten, dessen Vordertür, heben Sie sie an und nehmen Sie sie ab.

Once the work has been completed, refit the door belonging to this subrack and close it.

Bringen Sie nach Beendigung der Arbeiten die zu diesem Baugruppenträger gehörende Vordertür wieder an und schließen Sie sie.

When the front door is open − especially when additional covers have been removed − components with high operating temperatures may also become accessible.

Bei geöffneter Vordertür − insbesondere nach dem Öffnen von zusätzlichen Abde-ckungen − können auch Teile mit hoher Betriebstemperatur zugänglich sein.

2.2.2 Card Shieldings / Schirmungen der Baugruppen

Do not touch the contact springs of the card shieldings with the fingers or with the hand.

Berühren Sie die Kontaktfedern der Baugruppen-Schirmungen nicht mit den Fingern oder mit der Hand.

2.3 Weight / Gewicht Warning Labels at the subrack in case of heavy weight.

Warnschilder am Baugruppenträger bei hohem Gewicht.

The maximum weight to be lifted by one person is fixed to 18 kg!

Das maximale Hebegewicht für eine Person ist auf 18 kg festgelegt!

!!

!!

Page 13: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 13

2.4 Temperature / Temperatur

2.4.1 Device Cooling / Gerätekühlung The built-in ventilation installations must not be modified, and there must be sufficient air flow!

Vorhandene Lüftungseinrichtungen dürfen nicht verändert werden, und die aus-reichende Luftzirkulation darf nicht behindert sein.

Attention! Air condition devices have rotating items!

Achtung! Lüfterbaugruppen haben ro-tierende Teile!

2.4.2 Components Subject to High Operating Temperatures / Komponenten mit hoher Betriebstemperatur Warning Label for equipment components (e. g. heat sinks) which may attain high operating temperatures. Touching these components is liable to result in personal injury!

Warnschild für Geräteteile (z. B. Kühlkörper), die hohe Betriebstemperaturen erreichen können. Beim Berühren solcher Teile besteht Verletzungsgefahr!

2.5 Dust Filter / Staubfilter

Each fan unit can be equipped with a dust filter that cleans the cooling air from dust particles.

Jede Lüftereinheit kann mit einem Staubfilter ausgestattet werden, welches die Kühlluft von Staubpartikeln reinigt.

Provided that the environmental conditions (defined in ETS 300 019 class 3.1E) are fulfilled, replace the dust filter every three months. In addition, pay attention to possible notes from the filter manufacturer.

Vorausgesetzt, dass die Umweltbedin-gungen (entsprechend ETS 300 019 class 3.1E) erfüllt sind, ist das Staubfilter alle drei Monate auszuwechseln. Außerdem sind gegebenenfalls die Hinweise des Filterherstellers zu beachten.

!!

!!

!!

!!

Page 14: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

14 A42022-L5966-B 57-1-7620

2.6 Grounding and Potential Balancing / Erdung und Potenzialausgleich Especially when running a combination of different communications equipment, it is important to establish correct grounding and potential balancing between them − depending on the local grounding measures.

Insbesondere bei gemeinsamer Verwendung verschiedener Kommunikationsgeräte ist es wichtig − abhängig von den örtlichen Erdungsmaßnahmen − auf korrekten Erdungs- und Potenzialausgleich zu achten.

After mounting the systems into the rack, before attaching the connecting cables, and before commissioning, first check the grounding and potential balancing connections to agree with EN50310 and ETSI EN 300 253.

Nach dem Einbau der Systeme in das Gestell sind – vor dem Anschluss der Verbindungskabel und vor der Inbetriebnahme – die Erdungs- und Potenzialausgleichsverbindungen gemäß EN50310 und ETSI EN 300 253 zu über-prüfen.

The grounding must be effective as long as external cables are connected to the equipment.

Die Erdung muss bestehen bleiben, solange Kabel von außen an die Geräte angeschlossen sind.

If a subrack is not installed in a system rack you must ensure that it is properly grounded in some other way (according to ETSI EN 300 253).

Wenn die Baugruppenträger bzw. Einsätze nicht in einem Systemgestell montiert werden, müssen Sie auf andere Weise für geeignete Erdung sorgen (gemäß ETSI EN 300 253).

Grounding or potential balancing points are normally labeled with one of the signs shown below.

Erdungs- oder Potenzialausgleichspunkte sind normalerweise mit einem der nach-folgend dargestellten Zeichen gekennze-zeichnet

Protective earth (PE)

Schutzerde (PE)

Ground (E)

Erde (E)

In both rack and wall mounted applications, the subrack Protective earthing must be assured by connecting a PE cable as depicted in the Cabling Plan document. The PE cable must be connected before each other cable connection, and discon-nected last.

Sowohl bei Gestellmontage als auch bei Wandmontage des Baugruppenträgers muss die Schutzerdung dadurch sichergestellt sein, dass ein Schutzerdungskabel entsprechend dem Kabelführungsplan angeschlossen ist. Das Schutzerdungskabel muss als erste Verbindung (vor jeder anderen) ange-schlossen und als letzte Verbindung getrennt werden.

!!

ii

Page 15: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 15

2.7 Protection Against Excessive Overvoltage on the 48/60-Volts Power Supply Input / Schutz gegen Überspannungen beim 48/60-Volt-Stromversorgungseingang

A protection against excessive voltage is built in on the 48/60-Volts power supply input.

Ein Schutz gegen Überspannung auf der Stromversorgungs-Eingangsseite 48/60 V ist eingebaut.

The equipment must only be operated at a 48V/60V DC battery-based supply voltage, grounded at its positive pole and cor-responding to ETSI EN 300 132-2 and EN60950-1!

Das Gerät darf nur an einer batteriege-stützten, mit positivem Pol geerdeten 48V/60V-Versorgungs-Gleichspannung entsprechend ETSI EN 300 132-2 und EN60950-1 betrieben werden!

Observe the above note especially before connecting other equipment to the user/customer interfaces!

Beachten Sie den obigen Warnhin-weis insbesondere, bevor Sie andere Geräte an die Anwender-/ Kunden-Schnittstellen anschließen!

You must observe without fail the Protective earthing measures given in Chapter 2.6!

Beachten Sie unbedingt die Schutzerdungsmaßnahmen entsprechend Kapitel 2.6!

The subrack interfaces for alarms and TIF contacts are supplied by external power. The maximum allowable voltage must correspond to the SELV voltage limits (≤ 72V DC) respectively to the 48V/60V DC battery-based supply voltage according to ETSI EN 300 132-2!

Die Baugruppenträger-Schnittstellen für Alarme und TIF-Kontakte werden extern versorgt. Die maximal zulässige Spannung muss den SELV-Spannungsgrenzen entsprechen (≤ 72V Gleichspannung) bzw. den Spannungsgrenzen der batteriegestützten 48V/60V- Versorgungs-Gleichspannung gemäß ETSI EN 300 132-2!

!!

!!

Page 16: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

16 A42022-L5966-B 57-1-7620

2.8 Electrostatic Sensitive Components (ESD) / Elektrostatisch gefährdete Bauteile (EGB)

ESD Symbol Modules displaying this label are fitted with electrostatically-sensitive components, i.e. they must be handled in accordance with the necessary safety measures.

EGB/ESD-Symbol Baugruppen, die dieses Zeichen tragen, sind mit elektrostatisch gefährdeten Bauteilen bestückt, d. h. beim Umgang damit müssen die erforderlichen Sicherheits-maßnahmen eingehalten werden.

You must always wear a grounding bracelet that is connected properly when packing, unpacking, touching, pulling, or inserting modules displaying the ESD symbol. This will ensure these modules not to be damaged by electrostatic discharges.

Jeder, der Baugruppen mit EGB- / ESD- Symbol aus- oder einpackt, berührt, zieht oder steckt, muss stets ein vorschriftsmäßig angeschlossenes Erdungsarmband tragen. Dadurch ist sichergestellt, dass diese Baugruppen nicht durch elektrostatische Entladungen beschädigt werden.

Every printed circuit board has a grounding outer edge, which is connected to the ground terminal of the module. The board is only allowed to be touched or handled at this grounding edge - even if you are properly grounded.

Jede Leiterplatte hat einen Erdungs-außenrand, der mit dem Masseanschluss der Baugruppe verbunden ist. Die Leiterplatte darf - auch bei vorschriftsmäßiger Körpererdung- nur am Erdungsaußenrand angefasst werden.

When pulling and inserting modules, only use the integral plug and pull aids.

Verwenden Sie beim Ziehen und Stecken von Baugruppen nur die daran angebrachten Zieh- und Steckhilfen.

Modules which are located in a screened, unopened housing are protected at any rate against electrostatic discharges.

Baugruppen, die sich in einem abge-schirmten, ungeöffneten Gehäuse befinden, sind in jedem Fall vor elektrostatischen Entladungen geschützt.

The European Standards EN 61340-5-1 and -2 contain additional instructions on how to handle electrostatically-sensitive devices properly.

Die Europa-Normen EN 61340-5-1 und -2 geben zusätzliche Anleitungen zum sachgemäßen Umgang mit elektrostatisch gefährdeten Bauelementen.

!!

Page 17: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 17

2.9 Fiber-optic Cables and Connectors / Lichtwellenleiter und optische Steckverbinder

For laser safety remarks, see Chapter 2.10.

Laser-Sicherheitshinweise siehe Kapitel 2.10.

Optical connectors are precision-made components and must be handled accordingly. To ensure faultless functioning, the following points must be observed.

Optische Steckverbindungen sind Präzisionsteile und müssen dementsprechend behandelt werden. Eine einwandfreie Funktion ist nur dann sichergestellt, wenn nachfolgende Punkte berücksichtigt werden.

The minimum bending radius for optical fibers is 30 mm!

Für LWL-Leitungen darf ein Biegeradius von 30 mm nicht unterschritten werden!

Mechanical damage to the surfaces of optical connectors impairs transmission quality by higher attenuation.

Mechanische Beschädigungen der Stirn-flächen von optischen Steckverbindungen erhöhen die Dämpfung und mindern deshalb die Übertragungsqualität.

For this reason, do not expose the con-nectors to impact.

Vermeiden Sie deshalb Stoßbeanspru-chungen der Steckverbinder.

Always fit optical fiber connectors with protective caps to guard them against me-chanical damage and contamination. The protective dust caps should only be removed immediately prior to installation.

Schützen Sie LWL-Steckverbinder grund-sätzlich mit einer Schutzkappe vor mech-anischen Beschädigungen und Verschmutzungen. Die Staubschutzkappe soll erst unmittelbar vor dem Einbau entfernt werden.

Once the protective dust caps have been removed, you must check the surfaces of the optical fiber connectors to ensure that they are clean, and clean them if necessary.

Prüfen Sie nach Entfernen der Staub-schutzkappen die Stirnflächen der LWL- Stecker auf Sauberkeit und reinigen Sie sie gegebenenfalls.

For cleaning, a special optical fiber cleaning tool or a clean, lint-free cellulose cloth or a chamois leather is suitable. Freon TF, isopropyl alcohol (99 %), or white spirit can be used as cleaning fluids.

Zum Reinigen kann ein spezielles LWL- Reinigungswerkzeug oder ein einwandfrei sauberes, fusselfreies Zellstofftuch oder Fensterleder verwendet werden. Als Reinigungsflüssigkeit kann Freon TF, Iso-propylalkohol (99 %) oder Spiritus verwendet werden.

Page 18: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

18 A42022-L5966-B 57-1-7620

2.10 Laser Radiation / Laserstrahlung

2.10.1 Protection Against Extraneous Laser Light and Protection of the Optical Modules Concerned / Schutz gegen austretendes Laserlicht und Schutz der betreffenden optischen Baugruppen

Depending on the device type, the laser radiation may also be invisible for the human eye!

Je nach Gerätetyp kann die Laserstrah-lung für das menschliche Auge auch unsichtbar sein!

Devices and modules displaying either of the following warning labels contain laser devices.

Geräte und Baugruppen, die eines der fol-genden Warnzeichen tragen, enthalten Laser-Einrichtungen.

Warning Label according to EN 60825-1 / IEC 60825-1.

Warnschild nach EN 60825-1 / IEC 60825-1.

Warning Label for laser equipment as per EN 60825-1 / IEC 60825-1.

LASER CLASS 1

Warnschild für Laser-Einrichtungen entsprechend EN 60825-1 / IEC 60825-1.

When operated in a closed system, the laser equipment of the device conforms to class 1 safety level.

Bei Betrieb im geschlossenen System entsprechen die Laser-Einrichtungen des Gerätes der Gefährdungsklasse 1.

Nevertheless, in view of possible malfunc-tions, transmission systems which are fitted with optical fiber amplifier modules are classified as hazard level 1M. This hazard level is also applicable if the device is opened.

Unter Berücksichtigung von vorhersehbaren Fehlerfällen sind mit optischen Lichtwellenleiter-Verstärkerbaugruppen bestückte Übertragungssysteme jedoch der Gefährdungsklasse 1M zugeordnet. Diese Gefährdungsklasse gilt auch bei geöffnetem Gerät.

This hazard level is labelled as follows: Die Gefährdungsklasse ist folgendermaßen beschildert:

Warning Label according to EN 60825-2:2004 / IEC 60825-2:2004.

Warnschild nach EN 60825-2:2004 / IEC 60825-2:2004.

!!

Page 19: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 19

To ensure safe operation of the entire optical path, the laser safety shutdown must be activated, see Chapter 2.10.2.

Für den sicheren Betrieb der ge-samten optischen Strecke muss die Lasersicherheitsabschaltung aktiviert sein, siehe Kapitel 2.10.2.

Commissioning should be performed with fuse protection in the closed system.

Die Inbetriebnahme soll abgesichert im geschlossenen System erfolgen.

To avoid damage to health, you must

observe the regulations regarding protection against radiation from laser devices (EN 60825-1/ IEC 60825-1).

Zur Vermeidung gesundheitlicher Schäden müssen Sie die Vorschriften zur Strahlungssicherheit von Lasereinrichtungen (EN 60825-1 / IEC 60825-1) beachten.

If it cannot be avoided in an exceptional case to apply the hazard level 1M regu-lations (see above), you always must use dedicated laser-protective goggles.

Falls die Gefährdungsklasse 1M im Aus-nahmefall nicht vermieden werden kann (siehe oben), müssen Sie stets eine Laser-Schutzbrille tragen.

!!

Page 20: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

20 A42022-L5966-B 57-1-7620

2.10.2 Laser Safety Circuit / Lasersicherheitsabschaltung

Under normal operating conditions, the maximum transmit levels of the optical in-terface units stay below the limit values defined in EN 60825-1 / IEC 60825-1, Laser Class 1.

Unter normalen Betriebsbedingungen bleiben die maximalen Übertragungspegel der optischen Anschlussbaugruppen unterhalb der Grenzen, die nach EN 60825-1/ IEC 60825-1, Laser-Klasse 1, erlaubt sind.

However, all optical transmitters (except at the Ethernet interfaces) are fitted with automatic laser shutdown circuits to safe-guard against any possible hazard. This shutdown circuit can be configured and is active in the basic state. It trips, if no input signal is received by the optical receiver, i.e. if there is a break in the link. This prevents any uncontrolled laser emission if a fiber-optic connector is faulty or not connected.

Als Schutz gegen eventuelle Gefährdungen sind alle optischen Sender (außer an den Ethernet-Schnittstellen) mit einer au-tomatischen Laserabschaltung ausgestattet. Diese Abschaltung kann konfiguriert werden und ist grundsätzlich aktiv. Sie löst aus, wenn ein Eingangssignal am zugehörigen optischen Empfänger fehlt, z. B. bei unterbrochener Verbindung. Dies verhindert jede unkontrollierte Laserabstrahlung, wenn der optische Steckverbinder fehlerhaft oder nicht angeschlossen ist.

To ensure safe operation of the entire optical path, the laser safety shutdown must be activated.

Für den sicheren Betrieb der gesamten optischen Strecke muss die Laser-Sicherheitsabschaltung aktiviert sein.

Even with this safeguard, fiber-optic cables which are open at one end should always be considered to be “live”. Never look into open fiber-optic cable ends, as this may damage your eyes.

Auch unter Beachtung dieser Vorsichts-maßnahmen sollen Glasfaserkabel, die an einem Ende offen sind, immer so behandelt werden, als würden sie ständig Laserlicht führen. Nie direkt in die Enden sehen, da sonst die Augen geschädigt werden können!

In case of doubt always use dedicated laser-protective goggles!

Tragen Sie im Zweifelsfall stets eine Laserschutzbrille!

!!

!!

Page 21: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 21

2.10.3 Handling Batteries / Handhabung von Batterien Some equipment may contain accumulators or batteries of different technologies − e. g. lithium batteries or others.

Bestimmte Geräte können Akkumulatoren oder Batterien verschiedener Technologien enthalten − z. B. Lithium-Batterien oder andere.

Observe the following international

standards, if applicable: IEC 60130-17 (device interconnec-tions) IEC 61429 (recycling symbol) IEC 61438 (safety and health haz-ards) IEC 60086-4 (handling lithium bat-teries)

Beachten Sie gegebenenfalls auch folgende internationale Normen: IEC 60130-17 (Geräteverbindungen)IEC 61429 (Recyclingsymbol) IEC 61438 (Sicherheits- und Gesundheitsrisiken) IEC 60086-4 (Umgang mit Lithium- Batterien)

Pay attention to error messages re-ferring to the accumulator or the battery.

Achten Sie auf Fehlermeldungen, die sich auf den Akkumulator bzw. die Batterie beziehen.

Accumulators or batteries which are inte-grated in the device should only be replaced by the equipment manufacturer.

Ins Gerät eingebaute Akkumulatoren oder Batterien sollen nur beim Gerätehersteller ausgetauscht werden.

If replacement is necessary, do not remove the accumulator or the battery from the device, but send in the complete device / the module (card) or the removable battery pack.

Wenn ein Austausch erforderlich ist, dann bauen Sie nicht den Akkumulator oder die Batterie aus dem Gerät aus, sondern schicken Sie das komplette Gerät / die Baugruppe oder das herausnehmbare Batteriepack ein.

In order to prevent loss of data, the battery should only be replaced by the equipment manufacturer.

Zur Vermeidung von Datenverlust soll die Batterie nur durch den Gerätehersteller ausgetauscht werden.

There is risk of explosion if the battery is not replaced correctly!

Wenn die Batterie nicht ordnungsgemäß ausgetauscht wird, besteht Explosionsgefahr!

If you depollute batteries, you must observe the local regulations applicable to hazardous waste.

Beim Entsorgen von Batterien müssen die örtlichen Vorschriften über Beseitigung von Sondermüll eingehalten werden.

Never short circuit batteries directly without using a discharging resistor! Without a resistor very high current will flow causing a risk of explosion!

Schließen Sie niemals Batterien direkt ohne Entladewiderstand kurz! Ohne Widerstand können so hohe Ströme fließen, dass Explosionsgefahr besteht.

!!

!!

!!

Page 22: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

22 A42022-L5966-B 57-1-7620

2.10.4 Emergency Switching OFF / Notabschaltung

Especially if smoke or fire escapes from the device (or in other emergency situations), switch OFF the device immediately - by all relevant circuit breakers in the connector panel of the rack.

Insbesondere falls Rauch oder Feuer aus dem Gerät austritt (oder in anderen Notsituationen), schalten Sie das Gerät sofort aus - mit allen zugehörigen Sicherungsautomaten im Gestell- Anschlussfeld.

If possible, first switch OFF the protection power supply and then the working power supply.

Schalten Sie möglichst zuerst die Ersatz-Stromversorgung aus, dann die Betriebs-Stromversorgung.

However, consider that such an emergency shut-down can disconnect important communication lines which may be required just in the case of emergency.

Bedenken Sie jedoch, dass durch solch eine Notabschaltung wichtige Kommunikationsleitungen unterbrochen werden können, die gerade im Notfall eventuell dringend benötigt werden.

For this reason, shut down the device only if it is inevitable. Otherwise perform the normal switch-off procedure.

Nehmen Sie deshalb nur dann eine Notabschaltung vor, wenn es unumgänglich ist. Verfahren Sie sonst entsprechend der normalen Abschaltprozedur.

After the emergency shut-down, and if it is possible without danger, check if the device is dead - either by using a measuring device or by the LED display of the device, if ap-plicable.

Falls dies ohne Gefahr möglich ist, überprüfen Sie nach dem Notabschalten, ob das Gerät spannungsfrei ist - entweder mit einem Messgerät oder gegebenenfalls durch eine LED-Anzeige am Gerät.

Page 23: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 23

3 Troubleshooting

3.1 Indicator and Control Elements on the hiT 7020 Network Elements

3.1.1 LEDS The LED displays the status of modules, there are four types of LED on the Mainboard, they are PWR, CR, MJ and MN. These comprise faulty LEDs and service/alarm LEDs, which are used particularly in maintenance tasks. Before you open the System Management Interface or remove any modules from chassis of all NEs SURPASS hiT 7020 and when doing any work with the subrack open, you must observe the measures contained in Chapter 2.

The indication of LEDs is described in the SURPASS hiT 7020 Installation and Test Manual.

3.2 TNMS-M SURPASS hiT 7020 LCT Connection Description

3.2.1 IP Address Setting There are two IP address in the Network Element, the one is Ethernet IP address, the other is the Node IP address. First of all, you should set the IP address of the SURPASS hiT7020 LCT and the NE’s Ethernet IP address in the same subnet. Then, you should add the static route on the local Server where you installed the SURPASS hiT 7020. How to set the static route please refer to TNMS-M SURPASS hiT7020 3.2 LCT User Manual. The Ethernet IP address and the Node IP address in the NE are different to each other. FTP Service have to use Ethernet IP in boot mode while use the Node IP in the running mode.

3.2.2 Trap Destination Polling Mechanism TNMS-M SURPASS hiT 7020 LCT polls the NE connected to it periodically and adds the LCT's IP address into the NE's trap destination table automatically. LCT's IP address can be added into the NE's trap destination by clicking the "Apply" button on the trap destination dialog of LCT, this dialog does not support adding any other IP into NE’S trap destination table, because it is meaningless.

ii

Page 24: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

24 A42022-L5966-B 57-1-7620

3.3 Alarm Evaluation and Fault Isolation The Fig. 3.1 shows the basic options for alarm containment and alarm evaluation. Fig. 3.1 Basic Options for Alarm Containment and Alarm Evaluation Even without an operating terminal, it is possible to isolate faults as far as the module level with the aid of the module LEDs. Columns containing the relevant information are included in the alarm tables in Chapter 4.

3.4 Fault Clearance Procedures Refer to the ‘Actions’ rows in Alarm Tables in Chapter 4. They contain specific instructions regarding fault clearance.

3.4.1 Cables and Connectors Check the electrical connectors to ensure that they are fully engaged and that none of the pins is distorted. Check the optical fibers and optical connectors in accordance with the instructions given in Chapter 2. Check the cable layout (copper and optical fiber) in accordance with the wiring diagram.

3.4.2 Module Replacement Before replacing a module which is suspected of being defective, try to reactivate the system by means of a hardware reset (e. g. pulling and re-inserting the module), but do not do this if the red fault LED on the module is illuminated. When replacing modules, you must comply with the safety regulations, as described in Chapter 2.

See ITMN

On the screen of an operating terminal:Detailed identification of the alarm

LEDs on the front edge of the modules

Alarm

!!

Page 25: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 25

When replacing a module, it is essential to check and record the optical and the electrical transmitting power, using an optical or electrical power meter respectively, before the modules are returned to service. The module setup procedure can only commence once the module has been correctly inserted into the slot, as far as the stop, and then locked. Modules can be removed from or plugged into the slots while they are live. After a module has been replaced; the module status must be checked using the LCT or TNMS-M.

3.4.3 Special Fault Clearance In the event of faults occurring in the system which cannot be eliminated by applying the fault clearance procedures and instructions by the Alarm Tables, you can contact the relevant Siemens AG Service Agency. In order to provide effective support for the fault clearance operations, the following basic details will be required: - Complete reference numbers for the equipment affected by the fault - Software release numbers for the equipment affected by the fault - An accurate description of the fault (times of occurrence, apparent associations with

other factors, etc.) - Details of the attempts already made to rectify the fault.

!!

ii

Page 26: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

26 A42022-L5966-B 57-1-7620

4 Alarm Tables

4.1 Format and Content of Alarm Tables Each alarm message is described in a table format. The alarm message descriptions are listed in alphabetical order and each alarm message is explained within its accompanying table. Each alarm table uses the following format to describe information about the alarm:

Item Description

Alarm Description Describes the alarm and supplies additional information about the function of the equipment.

Alarm Category Describes the type of alarm. There are five (5) basic categories of alarm as shown and described below: • Communications alarm type: An alarm of this type is

principally associated with the procedures and/or processes required to convey information from one point to another;

• Quality of service alarm type: An alarm of this type is principally associated with a degradation in the quality of a service;

• Processing error alarm type: An alarm of this type is principally associated with a software or processing fault;

• Equipment alarm type: An alarm of this type is principally associated with an equipment fault;

• Environmental alarm type: An alarm of this type is principally associated with a condition relating to an enclosure in which the equipment resides.

Alarm Severity (default setting)

States the default severity of the alarm message. An alarm message can have the following 4 severity levels: • Critical • Major • Minor • Warning

Report to TNMS-M or LCT (default setting)

Indicates if the NE will send or not send the alarm message to the TNMS-M or LCT.

Local Indications Describes the visual indicators generated where the fault occurred.

Cause Refers to the cause of the alarm and provides more information about why the message was generated. It also provides details on the origin of the fault to assist operator in understanding and solving the problem.

Actions Actions that may help solve the problem, or suggests running specific tests for further diagnosis of the problem.

Note Alerts the user for any side effects or items that should be kept in mind when performing the corrective action.

Page 27: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 27

4.2 Alarm List

4.2.1 AU-AIS

Item Description Alarm Description The Alarm Indication Signal (AIS) is detected at the receiving

side of the path. AIS indicates that the signal cannot be used. Alarm Category Communication Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause A defect is detected in one of the upstream nodes leading to

the insertion of the alarm indication signal. Actions The alarm indication signal is reported for information only. No

action needs to be taken in the node where AIS is received. The node containing the defect is the node reporting VC-4 Remote Defect Indicator without the AU-4 Alarm indication signal received alarm. Check this node for other alarms.

Page 28: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

28 A42022-L5966-B 57-1-7620

4.2.2 AU-LOP

Item Description Alarm Description No valid AU-4 pointer is found in the received signal. Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause • Line unit failure in the remote node

• Local tributary unit failure in the station that reported the alarm. Actions Check remote line unit.

Check local line unit.

Page 29: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 29

4.2.3 E1-Negative_Bit-slip_TCA_15m

Item Description Alarm Description Negative Bit-slip number during a 15 minute period is greater than

or equal to the threshold. Alarm category QoS Alarm severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local indications The MN LED on the Main Controller is illuminated. Cause The clock frequency of the E1 service is faster than the frequency

of the system clock. Actions Check the Clock frequency of E1 Ports.

Page 30: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

30 A42022-L5966-B 57-1-7620

4.2.4 E1-Negative_Bit-slip_TCA_24h

Item Description Alarm Description Negative Bit-slip number during a 24 hour period is greater than or

equal to the threshold. Alarm category QoS Alarm severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local indications The MN LED on the Main Controller is illuminated. Cause The clock frequency of the E1 service is faster than the frequency

of system clock. Actions Check the Clock frequency of E1 Ports.

Page 31: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 31

4.2.5 E1-Positive_Bit-slip_TCA_15m

Item Description Alarm Description Positive Bit-slip number during a 15 minute period is greater than or

equal to the threshold. Alarm category QoS Alarm severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local indications The MN LED on the Main Controller is illuminated. Cause The clock frequency of the E1 service is slower than the frequency

of system clock. Actions Check the Clock frequency of E1 Ports.

Page 32: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

32 A42022-L5966-B 57-1-7620

4.2.6 E1-Positive_Bit-slip_TCA_24h

Item Description Alarm Description Numbers of negative bit-slip during 24 hours is more than or equal

to the threshold. Alarm category QoS Alarm severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local indications The MN LED on the Main Controller is illuminated. Cause The clock frequency of the E1 service is slower than the frequency

of system clock. Actions Check the Clock frequency of E1 Ports.

Page 33: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 33

4.2.7 Equipment_OverHeating

Item Description

Alarm Description The operating temperature of the NE reporting the alarm has exceeded the maximum permitted value.

Alarm Category Equipment

Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing.

Cause • Fan Failure • Empty slots which are not covered by blank faceplates • Dust Filter is dirty • Ambient temperature is extremely high

Actions Replace Fan. Cover all empty slots with blank faceplates. Clean Dust Filter. Provide cooling at least in the direct vicinity of the NE.

Note There is a high risk of seriously damaging circuit packs due to overheating.

Page 34: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

34 A42022-L5966-B 57-1-7620

4.2.8 Excessive_Bad_Bytes_Received_TCA_1s (LAN or WAN)

Item Description Alarm Description Bad Bytes received exceeds the provisioned threshold value. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated Cause • Erroneous routing of intermediate cabling

• Equipment fault(s) in the upstream station • Wrong LAN/WAN port configuration, such as PVID, VLAN

Actions Check upstream external cabling and equipment. Correct LAN/WAN port configuration.

Page 35: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 35

4.2.9 Excessive_Bad_Packets_Received_TCA_1s (LAN/WAN)

Item Description Alarm Description

Bad Packets received at LAN/WAN interface exceeds the provisioned threshold value.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications

The MN LED on the Main Controller is illuminated

Cause • Erroneous routing of intermediate cabling • Equipment fault(s) in the upstream station • Wrong LAN/WAN port configuration, such as PVID, VLAN

Actions Check upstream external cabling and equipment. Correct LAN/WAN port configuration.

Page 36: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

36 A42022-L5966-B 57-1-7620

4.2.10 Fan_Failure

Item Description Alarm Description Fan has failed. Alarm Category Equipment Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing. Cause Fan unit is defective. Actions Replace the fan unit.

Page 37: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 37

4.2.11 HP-DEG

Item Description Alarm Description The bit error ratio in the HP has exceeded the provisioned HP

Degrade Threshold. The quality of the transmission signal is degraded.

Alarm Category Communication Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause Fault(s) in upstream external cabling or equipment. Actions Check upstream external cabling and equipment.

Page 38: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

38 A42022-L5966-B 57-1-7620

4.2.12 HP-EXC

Item Description Alarm Description The bit error ratio in the HP has exceeded the provisioned HP

Excessive Error Threshold. The quality of the transmission signal is degraded.

Alarm Category Communication Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing. Cause Fault(s) in upstream external cabling or equipment. Actions Check upstream external cabling and equipment.

Page 39: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 39

4.2.13 HP-FE_BBE_TCA_15m

Item Description Alarm Description The HP far-end Performance Monitor BBE counter exceeded the

provisioned threshold during a 15-minute period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored blocks

have been detected at the downstream node. The HP BBE value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first complete

interval during which the counter value did not exceed the threshold value.

Page 40: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

40 A42022-L5966-B 57-1-7620

4.2.14 HP-FE_BBE_TCA_24h

Item Description Alarm Description The HP far-end Performance Monitor BBE counter exceeded the

provisioned threshold during a 24-hour period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored blocks have

been detected at the downstream node. The HP BBE value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first complete

interval during which the counter value did not exceed the threshold value.

Page 41: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 41

4.2.15 HP-FE_ES_TCA_15m

Item Description Alarm Description The HP far-end Performance Monitor ES counter exceeded the

provisioned threshold during a 15-minute period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored blocks

have been detected at the downstream node. The HP ES value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 42: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

42 A42022-L5966-B 57-1-7620

4.2.16 HP-FE_ES_TCA_24h

Item Description Alarm Description The HP far-end Performance Monitor ES counter exceeded the

provisioned threshold during a 24-hour period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored blocks

have been detected at the downstream node. The HP ES value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 43: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 43

4.2.17 HP-FE_SES_TCA_15m

Item Description Alarm Description The HP far-end Performance Monitor SES counter exceeded

the provisioned threshold during a 15-minute period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored blocks

have been detected at the downstream node. The HP SES value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 44: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

44 A42022-L5966-B 57-1-7620

4.2.18 HP-FE_SES_TCA_24h

Item Description Alarm Description The HP far-end Performance Monitor SES counter exceeded

the provisioned threshold during a 24-hour period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored

blocks have been detected at the downstream node. The HP SES value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 45: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 45

4.2.19 HP-FE_UAS_TCA_15m

Item Description Alarm Description

The HP far-end Performance Monitor UAS counter exceeded the provisioned threshold during a 15-minute period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored blocks

have been detected at the downstream node. The HP UAS value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 46: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

46 A42022-L5966-B 57-1-7620

4.2.20 HP-FE_UAS_TCA_24h

Item Description Alarm Description The HP far-end Performance Monitor UAS counter exceeded the

provisioned threshold during a 24-hour period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. QoS An indication returned to the upstream node that errored blocks

have been detected at the downstream node. The HP UAS value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 47: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 47

4.2.21 HP-GFP_Customer_Signal_Failure

Item Description Alarm Description Higher Order Path Customer Signal Failure Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause Fault(s) in upstream external cabling or equipment. Invalid PFI

byte received when the equipment is interworking with other equipment.

Actions Check the upstream external cabling and equipment.

Page 48: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

48 A42022-L5966-B 57-1-7620

4.2.22 HP-GFP_Loss_of_Frame_Delineation

Item Description Alarm Description Higher Order Path Loss of Frame Delineation Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause Fault(s) in upstream external cabling or equipment. Actions Check the upstream external cabling and equipment.

Page 49: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 49

4.2.23 HP-NE_BBE_TCA_15m

Item Description Alarm Description The HP Near-end Performance Monitor BBE counter exceeded

the provisioned threshold during a 15-minute period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 50: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

50 A42022-L5966-B 57-1-7620

4.2.24 HP-NE_BBE_TCA_24h

Item Description Alarm Description The HP Near-end Performance Monitor BBE counter exceeded

the provisioned threshold during a 24-hour period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first complete

interval during which the counter value did not exceed the threshold value.

Page 51: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 51

4.2.25 HP-NE_ES_TCA_15m

Item Description Alarm Description The HP Near-end Performance Monitor ES counter exceeded

the provisioned threshold during a 15-minute period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 52: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

52 A42022-L5966-B 57-1-7620

4.2.26 HP-NE_ES_TCA_24h

Item Description Alarm Description The HP Near-end Performance Monitor ES counter exceeded

the provisioned threshold during a 24-hour period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 53: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 53

4.2.27 HP-NE_SES_TCA_15m

Item Description Alarm Description The HP Near-end Performance Monitor SES counter exceeded

the provisioned threshold during a 15-minute period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 54: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

54 A42022-L5966-B 57-1-7620

4.2.28 HP-NE_SES_TCA_24h

Item Description Alarm Description The HP Near-end Performance Monitor SES counter exceeded

the provisioned threshold during a 24-hour period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first complete

interval during which the counter value did not exceed the threshold value.

Page 55: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 55

4.2.29 HP-NE_UAS_TCA_15m

Item Description Alarm Description The HP Near-end Performance Monitor UAS counter exceeded

the provisioned threshold during a 15-minute period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 56: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

56 A42022-L5966-B 57-1-7620

4.2.30 HP-NE_UAS_TCA_24h

Item Description Alarm Description The HP Near-end Performance Monitor UAS counter exceeded

the provisioned threshold during a 24-hour period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first complete

interval during which the counter value did not exceed the threshold value.

Page 57: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 57

4.2.31 HP-RDI

Item Description Alarm Description A Remote Defect Indication (RDI) is being received. Alarm Category Communication Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause The downstream NE that reported the alarm detects a

malfunction: HP-EXC, HP-TIM, or AU-4 AIS received. Actions No alarms in the reporting node. Check alarms from the

downstream NE and follow the clearing actions for those alarm(s).

Page 58: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

58 A42022-L5966-B 57-1-7620

4.2.32 HP-PJCN_TCA_15m

Item Description Alarm Description The AU Performance Monitor PJCN counter exceeded the

provisioned threshold during a 15-minute period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause When the input data rate is higher than the output data rate, a

Negative Pointer change will occur on the Node reporting the alarm.

Actions Set the NE reporting the alarm to synchronize with the other Node.

Note The alarm is cleared automatically at the end of the first complete interval during which the counter value did not exceed the threshold value.

Page 59: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 59

4.2.33 HP-PJCN_TCA_24h

Item Description Alarm Description The AU Performance Monitor PJCN counter exceeded the

provisioned threshold during a 24-hour period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause When the input data rate is higher than the output data rate, a

Negative Pointer change will occur on the Node reporting the alarm.

Actions Set the NE reporting the alarm to synchronize with the other Node.

Note The alarm is cleared automatically at the end of the first complete interval during which the counter value did not exceed the threshold value.

Page 60: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

60 A42022-L5966-B 57-1-7620

4.2.34 HP-PJCP_TCA_15m

Item Description Alarm Description The AU Performance Monitor PJCP counter exceeded the

provisioned threshold during a 15-minute period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause When the input data rate is lower than the output data rate, a

Negative Pointer change will occur on the Node reporting the alarm.

Actions Set the NE reporting the alarm to synchronize with the other Node.

Note The alarm is cleared automatically at the end of the first complete interval during which the counter value did not exceed the threshold value.

Page 61: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 61

4.2.35 HP-PJCP_TCA_24h

Item Description Alarm Description The AU Performance Monitor PJCP counter exceeded the

provisioned threshold during a 24-hour period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause When the input data rate is lower than the output data rate, a

Negative Pointer change will occur on the Node reporting the alarm.

Actions Set the NE reporting the alarm to synchronize with the other Node.

Note The alarm is cleared automatically at the end of the first complete interval during which the counter value did not exceed the threshold value.

Page 62: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

62 A42022-L5966-B 57-1-7620

4.2.36 HP-PLM

Item Description Alarm Description The received payload value, used to indicate the composition of

the VC-4 payload, does not match the provisioned value. Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause Payload composition of VC-4 at the node that reported the alarm

is not the same as the payload composition of VC-4 at its far-end station.

Actions If the received payload label is ≥ 1, check if the mapping mode of the local and far-end nodes is the same.

Page 63: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 63

4.2.37 HP-TIM

Item Description Alarm Description The received path trace identifier in the J1 byte of the VC-n or

STS-m Path Overhead (POH) does not match the expected path trace identifier.

Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause • Incorrectly connected line cables

• Wrong Expected Trace Identifier filled in via the management system for the network element that reported the alarm

Actions Determine in which network element(s) the line cables are incorrectly connected by interpreting the received VC-4 path trace identifiers. Check correctness of expected path trace identifier.

Page 64: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

64 A42022-L5966-B 57-1-7620

4.2.38 HP-UNEQ

Item Description Alarm Description VC-4 in STM-N signal not in use Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause Cross-connection is not consistently configured at both sides

(for example, at local and remote station). Actions Define or change the cross-connection at the other side so it

is consistent with the local side. Note When defining or changing a cross-connection this alarm will

almost inevitably come up as it is practically impossible to simultaneously issue the changes at both sides.

Page 65: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 65

4.2.39 HP-Virtual_Connection_LOA

Item Description Alarm Description Higher Order Path Virtual Concatenation-Loss of Alignment Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause Fault(s) in upstream external cabling or equipment. Actions Check the upstream external cabling and equipment.

Page 66: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

66 A42022-L5966-B 57-1-7620

4.2.40 HP-Virtual_Connection_LOM

Item Description Alarm Description Higher Order Path Virtual Concatenation-Loss of Multiframe Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause Fault(s) in upstream external cabling or equipment. Actions Check the upstream external cabling and equipment.

Page 67: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 67

4.2.41 Link_Failure

Item Description Alarm Description There is no incoming signal on the 10/100 BaseT Ethernet

interface unit. Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause • Interconnecting cabling contacts have a problem

• Receiver fault in indicated unit • Transmitter fault in the upstream equipment (not the

transmission system) • Discontinuity in the intermediate cabling • Erroneous routing of intermediate cabling

Actions Check connections between the indicated unit, the connecting panel, and the DDF (Digital Distribution Frame). Check upstream equipment (not part of the transmission system). Check intermediate cabling.

Page 68: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

68 A42022-L5966-B 57-1-7620

4.2.42 Loss_of_Timing_Input

Item Description Alarm Description No incoming signal on the indicated 2048K(Hz, bit/s) station

clock port. This is detected by the absence of pulses in the signal.

Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause Fault in the equipment producing the station clock.

Discontinuity in the cabling between the station clock supply equipment or erroneous routing.

Actions Check upstream equipment, such as the local exchange, producing the external clock reference. Check intermediate cabling connected to the related 2048K(Hz, Bit/s) station clock port

Page 69: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 69

4.2.43 Loss_of_Timing_Output

Item Description Alarm Description No station Clock output available. Alarm Category Equipment Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause The Station Clock Output Reference signal is not available. Actions Restore the Station Clock Output Reference signal.

Page 70: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

70 A42022-L5966-B 57-1-7620

4.2.44 LP-DEG

Item Description Alarm Description The bit error ratio in the LP has exceeded the provisioned

LP Degrade Threshold. The quality of the transmission signal is degraded.

Alarm Category Communication Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause Fault(s) in upstream external cabling or equipment. Actions Check the upstream external cabling and equipment.

Page 71: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 71

4.2.45 LP-EXC

Item Description Alarm Description The bit error ratio in the LP has exceeded the provisioned

LP Excessive Error Threshold. The quality of the transmission signal is degraded.

Alarm Category Communication Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing. Cause Fault(s) in upstream external cabling or equipment. Actions Check upstream external cabling and equipment.

Page 72: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

72 A42022-L5966-B 57-1-7620

4.2.46 LP-FE_BBE_TCA_15m

Item Description Alarm Description The LP far-end Performance Monitor BBE counter exceeded

the provisioned threshold during a 15-minute period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication has returned to the upstream node that errored

blocks have been detected at the downstream node. The LP BBE value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 73: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 73

4.2.47 LP-FE_BBE_TCA_24h

Item Description Alarm Description The LP far-end Performance Monitor BBE counter exceeded

the provisioned threshold during a 24-hour period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored

blocks have been detected at the downstream node. The LP BBE value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 74: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

74 A42022-L5966-B 57-1-7620

4.2.48 LP-FE_ES_TCA_15m

Item Description Alarm Description The LP far-end Performance Monitor ES counter exceeded

the provisioned threshold during a 15-minute period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication has returned to the upstream node that errored

blocks have been detected at the downstream node. The LP ES value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 75: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 75

4.2.49 LP-FE_ES_TCA_24h

Item Description Alarm Description The LP far-end Performance Monitor ES counter exceeded

the provisioned threshold during a 24-hour period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored

blocks have been detected at the downstream node. The LP ES value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 76: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

76 A42022-L5966-B 57-1-7620

4.2.50 LP-FE_SES_TCA_15m

Item Description Alarm Description The LP far-end Performance Monitor SES counter exceeded

the provisioned threshold during a 15-minute period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored

blocks have been detected at the downstream node. The LP SES value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 77: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 77

4.2.51 LP-FE_SES_TCA_24h

Item Description Alarm Description The LP far-end Performance Monitor SES counter exceeded

the provisioned threshold during a 24-hour period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored

blocks have been detected at the downstream node. The LP SES value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 78: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

78 A42022-L5966-B 57-1-7620

4.2.52 LP-FE_UAS_TCA_15m

Item Description Alarm Description The LP far-end Performance Monitor UAS counter exceeded

the provisioned threshold during a 15-minute period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored

blocks have been detected at the downstream node. The LP UAS value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 79: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 79

4.2.53 LP-FE_UAS_TCA_24h

Item Description Alarm Description The LP far-end Performance Monitor UAS counter exceeded

the provisioned threshold during a 24-hour period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored

blocks have been detected at the downstream node. The LP UAS value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 80: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

80 A42022-L5966-B 57-1-7620

4.2.54 LP-GFP_Customer_Signal_Failure

Item Description Alarm Description Lower Order Path Customer Signal Failure Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause Fault(s) in upstream external cabling or equipment. Actions Check the upstream external cabling and equipment.

Page 81: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 81

4.2.55 LP-GFP_Loss_of_Frame_Delineation

Item Description Alarm Description Lower Order Path Loss of Frame Delineation Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause Fault(s) in upstream external cabling or equipment. Actions Check the upstream external cabling and equipment.

Page 82: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

82 A42022-L5966-B 57-1-7620

4.2.56 LP-NE_BBE_TCA_15m

Item Description Alarm Description The LP Near-end Performance Monitor BBE counter

exceeded the provisioned threshold during a 15-minute period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 83: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 83

4.2.57 LP-NE_BBE_TCA_24h

Item Description Alarm Description The LP Near-end Performance Monitor BBE counter

exceeded the provisioned threshold during a 24-hour period.Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 84: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

84 A42022-L5966-B 57-1-7620

4.2.58 LP-NE_ES_TCA_15m

Item Description Alarm Description The LP Near-end Performance Monitor ES counter

exceeded the provisioned threshold during a 15-minute period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 85: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 85

4.2.59 LP-NE_ES_TCA_24h

Item Description Alarm Description The LP Near-end Performance Monitor ES counter

exceeded the provisioned threshold during a 24-hour period.Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 86: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

86 A42022-L5966-B 57-1-7620

4.2.60 LP-NE_SES_TCA_15m

Item Description Alarm Description The LP Near-end Performance Monitor SES counter

exceeded the provisioned threshold during a 15-minute period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 87: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 87

4.2.61 LP-NE_SES_TCA_24h

Item Description Alarm Description The LP Near-end Performance Monitor SES counter

exceeded the provisioned threshold during a 24-hour period.Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 88: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

88 A42022-L5966-B 57-1-7620

4.2.62 LP-NE_UAS_TCA_15m

Item Description Alarm Description The LP Near-end Performance Monitor UAS counter

exceeded the provisioned threshold during a 15-minute period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 89: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 89

4.2.63 LP-NE_UAS_TCA_24h

Item Description Alarm Description The LP Near-end Performance Monitor UAS counter

exceeded the provisioned threshold during a 24-hour period.Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 90: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

90 A42022-L5966-B 57-1-7620

4.2.64 LP-PLM

Item Description Alarm Description The received payload value, used to indicate the

composition of the VC-12 payload, does not match the expected value.

Alarm Category Communication Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing. Cause Payload composition of the VC-12 at the node that reported

the alarm is not the same as the payload composition of the VC-12 at its far end station.

Actions If the received payload is >=1, check if the mapping mode of the local and far-end nodes is the same.

Page 91: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 91

4.2.65 LP-RDI

Item Description Alarm Description A Remote Defect Indicator is being received. Alarm Category Communication Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause The downstream far end station of the node that reported

the alarm detects a malfunction at its receive side: VC-12 Excessive error rate, VC-12 Path signal label mismatch, or tributary unit alarm indication signal received.

Actions No alarms in the reporting node. React on the far-end alarms. Follow the clearing actions for those alarm(s).

Page 92: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

92 A42022-L5966-B 57-1-7620

4.2.66 LP-RFI

Item Description Alarm Description A Remote Defect Indicator is being received. Alarm Category Communication Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause VC-11 byte synchronous path Remote Failure Indication

(RFI). Actions React on the far-end alarms. Follow the clearing actions for

those alarm(s).

Page 93: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 93

4.2.67 LP-TIM

Item Description Alarm Description Mismatch between received trace ID and expected trace ID. Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause A provisioned trace string inserted in a VC-12 path was

received corrupted or not received at all, due to wrong configuration, hardware failures or transmission failures.

Actions Check cross-connections. Check tributary cables and tributary units.

Page 94: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

94 A42022-L5966-B 57-1-7620

4.2.68 LP-UNEQ

Item Description Alarm Description VC-12 in STM-N signal not in use. Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause Cross-connection not consistently defined at both sides (for

example, at local and remote station). Actions Define or change the cross-connection at the other side

consistent with the local side. Note When defining or changing a cross-connection this alarm will

almost inevitably come up as it is practically impossible to simultaneously issue the changes at both sides at the same moment.

Page 95: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 95

4.2.69 LP-Virtual_Concatenation_LOA

Item Description Alarm Description Lower Order Path Virtual Concatenation-Loss of Alignment Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause Fault(s) in upstream external cabling or equipment. Actions Check the upstream external cabling and equipment.

Page 96: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

96 A42022-L5966-B 57-1-7620

4.2.70 LP-Virtual_Concatenation_LOM

Item Description Alarm Description Lower Order Path Virtual Concatenation-Loss of Multiframe Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause Fault(s) in upstream external cabling or equipment. Actions Check the upstream external cabling and equipment.

Page 97: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 97

4.2.71 MS-AIS

Item Description Alarm Description The receive signal contains MS-AIS. MS-AIS is an indication

that Loss of Signal or Loss of Frame has been detected in the upstream equipment.

Alarm Category Communication Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Fault in an upstream node

• Equipment fault(s) in the local station Actions Check alarms in upstream nodes. Note AIS (all-ones signal) is inserted in the downstream direction.

RDI is inserted in the upstream (opposite) direction.

Page 98: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

98 A42022-L5966-B 57-1-7620

4.2.72 MS-DCC_Connection_Failure

Item Description Alarm Description No connection could be established on an enabled MS DCC

link. Alarm Category Communication Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing. Cause MS-DCC is disabled at one side of the MS DCC link. Actions Make sure that the MS-DCC is enabled at both ends of the

MS DCC link.

Page 99: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 99

4.2.73 MS-DEG

Item Description Alarm Description The bit error ratio in the MS has exceeded the provisioned

MS Degrade Threshold. The quality of the transmission signal is degraded.

Alarm Category Communication Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause Fault(s) in upstream external cabling or equipment. Actions Check upstream external cabling and equipment.

Page 100: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

100 A42022-L5966-B 57-1-7620

4.2.74 MS-EXC

Item Description Alarm Description The bit error ratio in the RS has exceeded the provisioned

MS Excessive Error Threshold. The quality of the transmission signal is degraded.

Alarm Category Communication Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing. Cause Fault(s) in upstream external cabling or equipment. Actions Check upstream external cabling and equipment.

Page 101: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 101

4.2.75 MS-FE_BBE_TCA_15m

Item Description Alarm Description The MS far-end Performance Monitor BBE counter

exceeded the provisioned threshold during a 15-minute period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored

blocks are detected at the downstream node. The MS BBE value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 102: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

102 A42022-L5966-B 57-1-7620

4.2.76 MS-FE_BBE_TCA_24h

Item Description Alarm Description The MS far-end Performance Monitor BBE counter

exceeded the provisioned threshold during a 24-hour period.Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored

blocks have been detected at the downstream node. The MS BBE value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 103: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 103

4.2.77 MS-FE_ES_TCA_15m

Item Description Alarm Description The MS far-end Performance Monitor ES counter exceeded

the provisioned threshold during a 15-minute period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored

blocks have been detected at the downstream node. The MS ES value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 104: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

104 A42022-L5966-B 57-1-7620

4.2.78 MS-FE_ES_TCA_24h

Item Description Alarm Description The MS far-end Performance Monitor ES counter exceeded

the provisioned threshold during a 24-hour period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored

blocks have been detected at the downstream node. The MS ES value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 105: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 105

4.2.79 MS-FE_SES_TCA_15m

Item Description Alarm Description The MS far-end Performance Monitor SES counter

exceeded the provisioned threshold during a 15-minute period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored

blocks have been detected at the downstream node. The MS SES value of the downstream node exceeded the provisioned threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 106: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

106 A42022-L5966-B 57-1-7620

4.2.80 MS-FE_SES_TCA_24h

Item Description Alarm Description The MS far-end Performance Monitor SES counter

exceeded the provisioned threshold during a 24-hour period.Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored

blocks have been detected at the downstream node. The MS SES value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 107: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 107

4.2.81 MS-FE_UAS_TCA_15m

Item Description Alarm Description The MS far-end Performance Monitor UAS counter

exceeded the provisioned threshold during a 15-minute period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored

blocks have been detected at the downstream node. The MS UAS value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 108: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

108 A42022-L5966-B 57-1-7620

4.2.82 MS-FE_UAS_TCA_24h

Item Description Alarm Description The MS far-end Performance Monitor UAS counter

exceeded the provisioned threshold during a 24-hour period.Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause An indication returned to the upstream node that errored

blocks have been detected at the downstream node. The MS UAS value of the downstream node exceeded the provision threshold.

Actions Check downstream external cabling. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 109: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 109

4.2.83 MS-K1/K2 Mismatch

Item Description Alarm Description MS Failure of Protocol

Invalid K1/K2 bytes received Alarm Category Communication Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing. Cause Improper protection configuration.

Crossed link between working section and protecting section.

Actions Check other transmission alarm. Check upstream equipment. Check whether conditions of protection switching are normal.

Page 110: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

110 A42022-L5966-B 57-1-7620

4.2.84 MS-NE_BBE_TCA_15m

Item Description Alarm Description The MS Near-end Performance Monitor BBE counter

exceeded the provisioned threshold during a 15-minute period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 111: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 111

4.2.85 MS-NE_BBE_TCA_24h

Item Description Alarm Description The MS Near-end Performance Monitor BBE counter

exceeds the provisioned threshold during a 24-hour period. Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 112: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

112 A42022-L5966-B 57-1-7620

4.2.86 MS-NE_ES_TCA_15m

Item Description Alarm Description The MS Near-end Performance Monitor ES counter

exceeded the provisioned threshold during a 15-minute period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 113: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 113

4.2.87 MS-NE_ES_TCA_24h

Item Description Alarm Description The MS Near-end Performance Monitor ES counter

exceeded the provisioned threshold during a 24-hour period.Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 114: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

114 A42022-L5966-B 57-1-7620

4.2.88 MS-NE_SES_TCA_15m

Item Description Alarm Description The MS Near-end Performance Monitor SES counter

exceeded the provisioned threshold during a 15-minute period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 115: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 115

4.2.89 MS-NE_SES_TCA_24h

Item Description Alarm Description The MS Near-end Performance Monitor SES counter

exceeded the provisioned threshold during a 24-hour period.Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 116: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

116 A42022-L5966-B 57-1-7620

4.2.90 MS-NE_UAS_TCA_15m

Item Description Alarm Description The MS Near-end Performance Monitor UAS counter

exceeded the provisioned threshold during a 15-minute period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 117: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 117

4.2.91 MS-NE_UAS_TCA_24h

Item Description Alarm Description The MS Near-end Performance Monitor UAS counter

exceeded the provisioned threshold during a 24-hour period.Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 118: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

118 A42022-L5966-B 57-1-7620

4.2.92 MS-RDI

Item Description Alarm Description The network element at the far end of the Multiplex Section

(in the downstream direction) has detected an error in the incoming signal and, as a consequent action, has inserted RDI (“110” in bits 6, 7 and 8 of the K2 byte) into the outgoing signal in the upstream direction.

Alarm Category Communication Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause The downstream equipment has detected a receive signal

failure, and has inserted MS-RDI as a consequent action. Actions Locally no actions can be taken. Analyze the alarm state of

the downstream equipment and take appropriate measures. Note The alarm is used when the downstream equipment has

detected one of the following failure conditions at its receiving side: MS AIS, LOS, and LOF. All these failures will be reported to the transmitting equipment via the Remote Defect Indication (RDI) bits to draw local attention to the remote failure.

Page 119: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 119

4.2.93 OA-Input_LOS

Item Description Alarm Description Optical Amplifier Loss Of Signal Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause • Cable failure or improper connection

• Dirty optical connector • Input optical power is below the pre-defined power

threshold value Actions Check the upstream external cabling and equipment.

Check the threshold in the management system.

Page 120: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

120 A42022-L5966-B 57-1-7620

4.2.94 OA-Output_LOS

Item Description Alarm Description Optical Amplifier Loss Of Signal Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause • Local transmitting module failure

• Output optical power is below the pre-defined power threshold value

Actions Check local transmitting module. Adjust the predefined output power threshold value.

Page 121: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 121

4.2.95 OA-Power_Failure

Item Description Alarm Description The OA module’s power has failed. Alarm Category Equipment Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause The OA’s power module does not work normally. Actions Replace this OA module with another one.

Page 122: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

122 A42022-L5966-B 57-1-7620

4.2.96 OA-Pump_Bias_Out_Of_Range

Item Description Alarm Description Pump bias is out of normal range. Alarm Category Equipment Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing. Cause Pump bias is too low or too high. Actions This OA’s output power out of range or this OA module can’t

work normally. Replace this OA module with another one.

Page 123: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 123

4.2.97 OA-Temperature_Bias_Out_Of_Range

Item Description Alarm Description The current temperature of the OA module is out of range. Alarm Category Equipment Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing. Cause Temperature of OA module is too high or too low. Actions Provide cooling at least in the direct vicinity of the NE.

Page 124: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

124 A42022-L5966-B 57-1-7620

4.2.98 PPI-LOS

Item Description Alarm Description There is no incoming signal on the PDH tributary port. This

is detected by the absence of transitions in the signal, that is, only zeros are received.

Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause • Interconnecting cabling contacts have a problem

• Receiver fault in indicated tributary unit • Transmitter fault in the upstream equipment (not the

Transmission System) • Discontinuity in the intermediate cabling • Erroneous routing of intermediate cabling

Actions Check connections between the indicated tributary unit, the connecting panel, and the DDF (Digital Distribution Frame). Check tributary receiver port of the indicated tributary unit by looping the data at the DDF. Check upstream equipment (not part of the transmission system). Check intermediate cabling.

Page 125: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 125

4.2.99 RS-BBE_TCA_15m

Item Description Alarm Description The RS near-end Performance Monitor BBE counter

exceeded the provisioned threshold during a 15-minute period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 126: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

126 A42022-L5966-B 57-1-7620

4.2.100 RS-BBE_TCA_24h

Item Description Alarm Description The RS near-end Performance Monitor BBE counter

exceeded the provisioned threshold during a 24-hour monitoring period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 127: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 127

4.2.101 RS-DCC_Connection_Failure

Item Description Alarm Description No connection could be established on an enabled RS DCC

link. Alarm Category Communication Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing. Cause RS-DCC is disabled at one side of the RS DCC link. Actions Make sure that the RS-DCC is enabled at both ends of the

RS DCC link.

Page 128: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

128 A42022-L5966-B 57-1-7620

4.2.102 RS-DEG

Item Description Alarm Description The bit error ratio in the RS has exceeded the provisioned

RS Degrade Threshold. The quality of the transmission signal is degraded.

Alarm Category Communication Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause Fault(s) in upstream external cabling or equipment. Actions Check upstream external cabling and equipment.

Page 129: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 129

4.2.103 RS-ES_TCA_15m

Item Description Alarm Description The RS near-end Performance Monitor ES counter

exceeded the provisioned threshold during a 15-minute period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 130: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

130 A42022-L5966-B 57-1-7620

4.2.104 RS-ES_TCA_24h

Item Description Alarm Description The RS near-end Performance Monitor ES counter

exceeded the provisioned threshold during a 24-hour monitoring period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 131: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 131

4.2.105 RS-EXC

Item Description Alarm Description The bit error ratio in the RS has exceeded the provisioned

RS Excessive Error Threshold. The quality of the transmission signal is degraded.

Alarm Category Communication Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing. Cause Fault(s) in upstream external cabling or equipment. Actions Check upstream external cabling and equipment.

Page 132: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

132 A42022-L5966-B 57-1-7620

4.2.106 RS-LOF

Item Description Alarm Description The position of the frame alignment bytes (A1/A2 bytes)

cannot be detected correctly in the receive signal. Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause • The receive signal does not match the port rate (for

example, this could be caused by a misconnected fiber, such as an STM-1 signal is received at an STM-4 port)

• The Section Overhead of the SDH receive signal is not correctly structured (due to a failure of the transmit circuit pack at the far end)

• The receiver at the circuit pack reporting the alarm is defective

Actions Check intermediate fiber. Clean dirty connectors. Check if Unit failure is reported for the unit generating the SDH frame alignment signal. If so, remove the defective unit and replace it with a new one. Loop the signal at the transmitting network element and at the receiving network element. If the network element reporting the LOF contains the faulty unit, replace the unit with a new one.

Note AIS (all-ones signal) is inserted in the downstream direction.RDI is inserted in the upstream (opposite) direction.

Page 133: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 133

4.2.107 RS-SES_TCA_15m

Item Description Alarm Description The RS near-end Performance Monitor SES counter

exceeded the provisioned threshold during a 15-minute period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 134: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

134 A42022-L5966-B 57-1-7620

4.2.108 RS-SES_TCA_24h

Item Description Alarm Description The RS near-end Performance Monitor SES counter

exceeded the provisioned threshold during a 24-hour monitoring period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 135: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 135

4.2.109 RS-UAS_TCA_15m

Item Description Alarm Description The RS near-end Performance Monitor UAS counter

exceeded the provisioned threshold during a 15-minute period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 136: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

136 A42022-L5966-B 57-1-7620

4.2.110 RS-UAS_TCA_24h

Item Description Alarm Description The RS near-end Performance Monitor UAS counter

exceeded the provisioned threshold during a 24-hour monitoring period.

Alarm Category QoS Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause • Dirty optical connector(s)

• Equipment fault(s) in the upstream station Actions Check upstream external cabling and equipment. Note The alarm is cleared automatically at the end of the first

complete interval during which the counter value did not exceed the threshold value.

Page 137: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 137

4.2.111 RS-TIM

Item Description Alarm Description The received RS trace identifier, used to verify the continued

connection to the intended transmitter, does not match the provisioned value.

Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause • Improperly connected fibers

• Wrong expected trace identifier filled in via the SNM or LCT for the node that reported the alarm

Actions Determine in which node(s) the fibers are improperly connected by interpreting the received RS trace identifiers. Check correctness of expected RS trace identifier.

Page 138: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

138 A42022-L5966-B 57-1-7620

4.2.112 SFP_Failure

Item Description Alarm Description SFP Module can not work normally. Alarm Category Equipment Alarm Severity (default setting)

Major

Report to TNMS-M or LCT (default setting)

Yes

Local Indications The MJ LED on the Alarm Panel is flashing. Cause Laser Fault Actions Replace SFP module.

Page 139: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 139

4.2.113 SFP_Mismatch

Item Description Alarm Description SFP Module can not work normally. Alarm Category Equipment Alarm Severity (default setting)

Major

Report to TNMS-M or LCT (default setting)

Yes

Local Indications The MJ LED on the Alarm Panel is flashing. Cause • The bit rate of SFP is lower than the port required

• An Electrical SFP is inserted Actions Replace the mismatched SFP module with a suitable SFP

module.

Page 140: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

140 A42022-L5966-B 57-1-7620

4.2.114 System_Clock_Unlocked

Item Description Alarm Description The System Clock State is not Locked. Alarm Category Communication Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing. Cause • System clock mode has been changed from locked to

holdover or free-running mode manually • The System Clock State is in holdover mode because of

all Timing reference signals have failed Actions Change the System Clock State to Locked.

Check timing reference signal.

Page 141: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 141

4.2.115 SPI-LOS

Item Description Alarm Description The optical input power at the corresponding port is too low.

Frame alignment and synchronization to the received signal is not possible. When gradually decreasing the optical input power below the receiver sensitivity limit, first a Loss of Frame will be reported, and if it becomes even lower a Loss of Signal will be reported.

Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. The Link LED of Port which reporting LOS is extinguished.

Cause • Fiber failure • Dirty optical connector(s) • Equipment fault(s) in the upstream far-end station of the

network element that reported the alarm Actions Check the operation of the transmitter in the far-end station.

Check if there are any fiber breaks. Clean if there are any dirty connectors.

Note In the upstream direction, “MS - Remote Defect Indicator” is activated.

Page 142: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

142 A42022-L5966-B 57-1-7620

4.2.116 System_Clock_Holdover_Longer

Item Description Alarm Description The System Clock State of NE has been in “Holdover” more

than 24 hours. Alarm Category Communication Alarm Severity (default setting)

Warning

Report to SNM or LCT(default setting)

Yes

Local Indications None Cause All Timing reference signals have failed. Actions Check equipment in upstream far end station.

Check upstream cabling.

Page 143: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 143

4.2.117 Synchronization_Signal_Message_Mismatch

Item Description Alarm Description Synchronization Signal Message Mismatch Alarm Category Communication Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing. Cause Invalid SSM byte. Actions Check whether the value of SSM byte is a legal value.

Page 144: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

144 A42022-L5966-B 57-1-7620

4.2.118 TU-AIS

Item Description Alarm Description The VC-12 payload signal is replaced by the alarm indication

signal. This is detected by checking the TU-12 pointer bytes for an all 1s pattern.

Alarm Category Communication Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause In one of the upstream nodes a defect was detected which

led to the insertion of the alarm indication signal. Actions No action needed in the alarm reporting node.

Alarm indication signal is reported for information only.

Page 145: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 145

4.2.119 Timing_Reference_Degrade

Item Description Alarm Description Timing Reference Degrade Alarm Category Communication Alarm Severity (default setting)

Minor

Report to SNM or LCT(default setting)

Yes

Local Indications The MN LED on the Main Controller is illuminated. Cause Timing reference signal may be degraded or failing. Actions Check equipment in the upstream far end station.

Check upstream cabling.

Page 146: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

146 A42022-L5966-B 57-1-7620

4.2.120 Timing_Reference_Failure

Item Description Alarm Description The Timing reference signal is not acceptable as timing

source. Alarm Category Communication Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing. Cause Timing reference signal may be failing. Actions Check equipment in the upstream far end station.

Check upstream cabling.

Page 147: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 147

4.2.121 TU-LOM

Item Description Alarm Description Alignment to the multi-frame structure of the received VC-

4/VC-3 signal is not possible. Therefore VC-12/VC-2 overhead and payload data cannot be extracted.

Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause • Unit failure in the upstream network element that

generated the H4 multiframe • Alignment signal or faulty unit within the network

element that reported the alarm. Actions Check on the management system if unit failure is reported

for the unit generating the H4 multiframe alignment signal. In that network element, replace the unit with a new one. If a unit failure is not reported, loop the STM-1 signal at the transmitting network element and at the receiving network element. In this condition, the network element reporting VC-4 Loss of multiframe contains the faulty unit.

Page 148: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

148 A42022-L5966-B 57-1-7620

4.2.122 TU-LOP

Item Description Alarm Description No valid tributary unit pointer interpretation obtained in

received signal. Alarm Category Communication Alarm Severity (default setting)

Critical

Report to SNM or LCT(default setting)

Yes

Local Indications The CR LED on the Main Controller is flashing. Cause Unit failure in the upstream node that generated the TU

pointer or in the node that reported the alarm. Actions Check on the management system if unit failure is reported

for the unit generating the TU pointer. In that node, remove the unit and replace it with a new one. If a unit failure is not reported, loop the STM-n signal at the transmitting node and at the receiving node. In this condition, the node reporting TU Loss of pointer contains the faulty unit.

Page 149: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 149

4.2.123 Unit_Failure

Item Description Alarm Description A Unit failure has been detected. Alarm Category Equipment Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing. Cause Unit can not work normally because of hardware failure,

firmware failure, or other conditions resulting in unit not working.

Actions If the alarm is still present after 1 minute, then remove the Unit and replace it with another one.

Page 150: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

150 A42022-L5966-B 57-1-7620

4.2.124 Unit_Removal

Item Description Alarm Description Unit removed Alarm Category Equipment Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing. Cause Unit is not present. Actions If the Unit is still needed, reinstall the unit into its slot position.

If the Unit is not needed, delete it using the SNM.

Page 151: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 151

4.2.125 UnitType_Mismatch

Item Description Alarm Description Unit Type Mismatch Alarm Category Equipment Alarm Severity (default setting)

Major

Report to SNM or LCT(default setting)

Yes

Local Indications The MJ LED on the Main Controller is flashing. Cause The inserted circuit-pack type is not consistent with the

preconfigured unit type. Actions Replace with the correct circuit-pack.

Un-plug the mismatched circuit-pack and delete the circuit-pack via Network Management System.

Page 152: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

152 A42022-L5966-B 57-1-7620

Page 153: SURPASS HiT 7020 Troubleshooting Manual 3p2

Maintenance Troubleshooting ManualSURPASS hiT 7020 3.2

A42022-L5966-B 57-1-7620 153

5 Abbreviations

ACO Alarm Cut Off Bw7R Style 7R CD-ROM Compact Disc Read Only Memory CE Communauté Européenne DB Data Base DC Direct Current DCC Data Communication Channel EGB Elektrostatisch Gefährdete Bauteile EMC Electromagnetic Compatibility EN European Standard EOW Engineering Order Wire ESD Electrostatic Sensitive Device ETS European Telecommunication Standard ETSI European Telecommunications Standards Institute F Standardized interface for connection of a local terminal FAULT Fault Alarm LED FO Fiber Optic GMT Greenwich Mean Time GND Ground GUI Graphical User Interface GUIMN Graphical User Interface Manual HS Handset HW Hardware IEC International Electrotechnical Commission ITMN Installation and Test Manual LCAS Link Capacity Adjustment Scheme LCT Local Craft Terminal LED Light Emitting Diode LWL Lichtwellenleiter (optical fiber) MSP Multiplex Section Protection NCT Network Craft Terminal NUBAT Negative Power Supply Voltage OK Service LED OSN Optical Service Node PDF Portable Document Format PE Protective Earth (Ground) PPP Point to Point Protocol PUBAT Positive Power Supply Voltage

Page 154: SURPASS HiT 7020 Troubleshooting Manual 3p2

Troubleshooting Manual Maintenance SURPASS hiT 7020 3.2

154 A42022-L5966-B 57-1-7620

RAM Random Access Memory Rx Received signal SDI Serial Debug Interface SEC SDH Equipment Clock SELV Separate Extra-Low Voltage SFP Small Form Factor Pluggable (Module) SNCP Sub-Network Connection Protection SW Software T3 Clock input T4 Clock output TED Technical Description TIF Telemetry Interface TNMS CT Telecommunication Network Management System Craft Terminal Tx Transmitted signal UMN User Manual VCDB Variable Configuration Data Block