surface contamination meter by acmas technologies pvt ltd
DESCRIPTION
Ultraviolet UV-C Meters/Detectors For More Information Please Logon http://cutt.us/M6xP7TRANSCRIPT
R
SURFACE CONTAMINATION METER
MODEL NO.- ACM-SCM-2637
There have been developed some classical methods for study of surfaces which are in use even today. These
include adsorption isotherms, measurements of surface roughness, ellipsometry, reflectivity, and microscopy.
All real-world samples are contaminated as a result of atmospheric contact. A metal sample when kept in
normal atmospheric conditions for an hour will attract a contamination layer of carbon on its surface. The easily
oxidized metals get on their surface a contamination of oxide layer.
Ÿ Pharmaceuticals
Ÿ Food Processing
Ÿ Electronics
Ÿ Surface Plating and coating
Ÿ Film Type surface contaminants
Ÿ Particulate surface contaminant
Weiber Surface Contamination Meter is ideal equipment for research and general applications in the field of
analysis of surface contamination. Our equipment measures alpha, beta, gamma and x-
IMPORTANCE OF CONTAMINATION CONTROL
CATEGORIES OF SURFACE CONTAMINANTS
PRODUCT OVERVIEW
R
SURFACE CONTAMINATION METER
MODEL NO.- ACM-SCM-2637
TECHNOLOGIES PVT. LTD.
Ÿ Our equipment is of foremost importance in the following processes:
Ÿ Research and Development
Ÿ Manufacturing
Ÿ Quality Control
Ÿ Aerospace
Ÿ Optics
Ÿ Biomedical
Ÿ Xerography
Ÿ Improves safety in laboratories and in the field
Ÿ Automaticallycompensates forGM tube dead time
Ÿ Anti-saturation circuitry prevents jamming in high radiation fields
Ÿ Meets CE certification requirements for Europe
Ÿ Safety-first calibration feature can eliminate personnel exposure during calibration.
PRODUCT FEATURES
APPLICATIONS
radiation using a 2-inch pancake GM Detector with high sensitivity to common beta and alpha sources.
The easy-to-read digital display shows readings in your choice of mR/hr, CPM, CPS, or mSv/hr. The
Total/Timer feature allows timed readings from one minute to 24 hours for precise measurement of low-level
contamination.
R
TECHNOLOGIES PVT. LTD.
Surface cleanliness is essential when applying the replication methods; it is less significant when viewing the
specimen directly by the scanning electron microscope. Surface damage any analytical measurement should
not change the sample being measured. If the condition of the measurement or the probe with which the
analysis is being done changes or damages the sample, the results of the analysis will be incorrect.
Ÿ 4 digit LCD with mode indicators
LCD displays updates every 3 seconds, showing the average for the past 30 second time period at
normal levels.
Ÿ Wipe Test Plate
Ÿ External scintillation probe
PRODUCT FEATURES
TECHNICAL FEATURES
OPTIONAL ACCESSORIES
R
TECHNOLOGIES PVT. LTD.
mR/hr
CPM
Total
mSv / hr
CPS
Efficiency
Sensitivity
Accuracy
Timer :
Can set 1-10 minute sampling periods in
1-minute increments,
10-50 minute sampling periods in 10-
minute increments, and
1-24 hour sampling periods in 1-hour
increments
Temperature Range
Power
.001 to 100.0
0 to 300,000
1 to 9,999,000 counts
.01 to 1,000
0 to 5,000
Sr-90 (546KeV, 2.3MeV bmax
3500 CPM / mR / hr referenced to Cs-137
±15% 0-50 mR / hr; ± - 20 % 50 - 100 mR / hr
-10 ºC to +50C (14 ºF to 122 ºF)
One 9-volt alkaline battery; battery life is minimum 200
hours at normal background, minimum 24 hours at 1
mR / hr
OPERATING RANGE
R
TECHNOLOGIES PVT. LTD.
www.acmasindia.com | www.acmasglobal.com | www.measuring-meters.com
SALES OFFICE (HONG KONG)
SALES OFFICE (RUSSIA)
Unit D 28 11/F Wing Tat Comm,Bidg 97, Bonham Strand East,
Sheung Wan, Hong Kong (PRC)
Tel.: 0086-13929598046 | 0086- 18922303099
E-mail.: [email protected]
Inmed Trade Street Ozerkovsky Embankment,
Unit No 50, Straine- 1, Off- 502, Moscow, Russia
E-mail.: [email protected]
Tel.: 0049- 79592345 | Email: [email protected]
TECHNOLOGIES PVT. LTD.
An ISO 9001 : 2208 | ISO 14001 : 2008 | ISO 13485
WHO: GMP Products | GLP Compliant Products
CORPORATE OFFICE/ (INDIA)SHOWROOM
Plot No. 352-353, Sector – 57
Phase- IV Kundli, Sonepat, Haryana - 131028
Land Line No.: +91 - 11- 47619688,
Fax: +91-11-47619788
E-mail.: [email protected]