    Since 1987, Superior X-Ray Tube Company has been manufacturing quality x-ray tubes. We take pride inour diverse product line which is used in a wide range of applications, including, medical, dental, thicknessgauging, food inspection, bone densitometry, Non-Destructive Testing (NDT), and X-Ray Fluorescence

    (XRF) Spectroscopy. We have a global customer base including Japan, China, Korea, Europe, Canada, andthe USA.

    Superior X-Ray manufactures a wide variety of x-ray tubes with focal spots ranging from 50 microns to 2.8

    mm and with operating voltages from 35kV up to 130 kV using standard tungsten target material. All of ourtubes come with a 15 month pro-rated warranty covering defects due to materials or workmanship when

    used within the tubes specified operating limits.

    Other target materials and custom tube designs are available in minimum order sizes of 100 pieces. Pleasecontact us to discuss custom designs.

    We would be happy to assist you in meeting your current and future x-ray tube needs. Our companyinformation is as follows:

    Superior X-ray Tube Company Phone: 815-338-4424 Fax: 815-338-9452

    1220 Claussen Drive email: [email protected]

    Woodstock, IL 60098 Website: www.superiorxraytube.com

    U.S.A

    Thank you for taking the time to review our catalog, we look forward to hearing from you.

    Sincerely,

    Mark McDonnellPresident

    Superior X-ray Tube Company

  • 8/18/2019 Superior X-ray Tube Co.

    3/58

  • 8/18/2019 Superior X-ray Tube Co.

    4/58

    Pa

    GLASS WINDOW TUBES

    SXR-80PEANUT SERIES

    SEE PAGES 1 THRU 6

    SXR-15SEE PAGES 7 AND 8

    SXR-15PTSEE PAGES 9 AND 10

    SXR-90-15EE PAGES 11 THRU 16

  • 8/18/2019 Superior X-ray Tube Co.

    5/58

    Pag

    GLASS WINDOW TUBES

    SXR-100-15SEE PAGES 17 AND 18

    SXR-100-25SEE PAGES 19 AND 20

    SXR-100-20 SERIESEE PAGES 21 THRU 24

    SXR-100-45EE PAGES 25 THRU 28

  • 8/18/2019 Superior X-ray Tube Co.

    6/58

    Pag

    BERYLLIUM WINDOW TUBES

    SXR-50BWPEANUT SERIES

    EE PAGES 29 THRU 34

    SXR-212BWSEE PAGES 41 AND 42

    SXR-80BWPEANUT SERIES

    EE PAGES 35 THRU 40

  • 8/18/2019 Superior X-ray Tube Co.

    7/58

    Pa

    BERYLLIUM WINDOW TUBES

    SXR-35-05BWSEE PAGES 45 AND 46

    SXR-130-05BWSEE PAGES 49 AND 50

    SXR-80-05BWSEE PAGES 47 AND 48

  • 8/18/2019 Superior X-ray Tube Co.

    8/58

    Pag

    Superior X-ray Tube Company

    Customer Tube Request

    In order to select an x-ray tube that will work properly in your application, please provide us with as much

    information as possible.

    kVp: _____________What peak or continuous voltage will be applied to the tube?

    Generator Type: _____________

    Self-Rectified, Full Wave Rectified, or Constant Potential (DC)

    Tube Operation: _____________Will the voltage be applied to (1) the anode with the cathode cup grounded, or (2) the cathode cup with the anod

    grounded, or (3) bipolar operation with ½ the voltage on the anode and ½ the voltage on the cathode?

    mA: _____________

    What is the maximum tube current at kVp ?

    Duty Cycle: _____________ (On Time)  _____________ (Off Time)

    What is the exposure time (i.e. time the tube is on) and the time between exposures?

    Focal Spot:  _____________What is the desired focal spot size?

    Anode Target Angle: _____________

    Desired X-ray Beam Coverage Area: _____________When the x-ray beam reaches the person/object under study, the area receiving x-ray energy is referred to as the

    “coverage area”. The angle of the anode and the distance from the tube target to the person/object determines thmaximum x-ray tube coverage. The coverage may be reduced by filters or collimators inside the x-ray tube head

    Tube Cooling Method: ____________________________________________

    Oil, Air, Silicone Insulating Material, etc.?Sealed or open oil bath?

    Any additional forced cooling (fins, radiators, heat exchangers)?

    Physical Tube Constraints: _________________________________________Please detail any constraints on the physical dimensions of the tube.

    Type of Application: ______________________________________________

    Dental, Medical, Industrial?

    Other Requirements (For example, do you require a shield, flange, lead wires, or special anode/cathodebasing?): __________________________________________________________________________________

     __________________________________________________________________________________________

  • 8/18/2019 Superior X-ray Tube Co.

    9/58

    Pa

    Operating Data

    Available focal spot size (mm):

    0.20

    Available target angle:14°

    Anode construction:

    Vacuum cast copper with tungsten target

    Cathode construction:Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:80 kVp Full wave rectified

    Max. Continuous tube currentat 80 kVp:0.60 mA

    Inherent filtration/Window material:

    1.5 mm/Glass

    Cooling Method:High dielectric transformer oil

    SXR-80-14-2P0.20 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    10/58

    Pa

    SXR-80-14-2P

  • 8/18/2019 Superior X-ray Tube Co.

    11/58

    Pa

    Operating Data

    Available focal spot size (mm):1.0

    Available target angle:

    14°

    Anode construction:Vacuum cast copper with tungsten target

    Cathode construction:

    Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:

    80 kVp Full wave rectified

    Max. Continuous tube currentat 80 kVp:

    0.75 mA

    Inherent filtration/Window material:1.5 mm/Glass

    Cooling Method:

    High dielectric transformer oil

    SXR-80-10P1.0 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    12/58

    Pa

    SXR-80-14-10P

  • 8/18/2019 Superior X-ray Tube Co.

    13/58

    Pa

    Operating Data

    Available focal spot size (mm):

    0.50

    Available target angle:14°

    Anode construction:

    Vacuum cast copper with tungsten target

    Cathode construction:Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:

    80 kVp Full wave rectified

    Max. Continuous tube current

    at 80 kVp:0.70 mA

    Inherent filtration/Window material:

    1.5 mm/Glass

    Cooling Method:High dielectric transformer oil

    SXR-80-20-5P0.5 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    14/58

    Pa

    SXR-80-20-5P

  • 8/18/2019 Superior X-ray Tube Co.

    15/58

    Pa

    Operating Data

    Available focal spot size (mm):1.0

    Available target angle:

    15°

    Anode construction:Vacuum cast copper withtungsten target

    Cathode construction:Vacuum tube nickel with tungstenfilament.

     

    Max. Tube operating voltage:

    100 kVp / 110 kVpInverse full wave and self rectified.

    Max. Continuous tube currentat 100 kVp:1.0 mA

    Inherent filtration/Window material:

    1.5 mm/Glass

    Cooling Method:High dielectric transformer oil

    SXR-151.0 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    16/58

    Pa

    SXR-15

  • 8/18/2019 Superior X-ray Tube Co.

    17/58

    Pa

    Operating Data

    Available focal spot sizes (mm):

    1.0

    Available target angles:15°

    Anode construction:

    Vacuum cast copper with tungsten target

    Cathode construction:Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:100 kVp / 110 kVp

    Inverse full wave and self rectified

    Max. Continuous tube currentat 100 kVp:

    1.0 mA

    Inherent filtration/Window material:1.5 mm/Glass

    Cooling Method:

    High dielectric transformer oil

    SXR-15PT1.0 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    18/58

    Pag

    SXR-15PT

  • 8/18/2019 Superior X-ray Tube Co.

    19/58

    Pag

    Operating Data

    Available focal spot sizes (mm):

    0.5

    Available target angles:15°

    Anode construction:

    Vacuum cast copper with tungsten target

    Cathode construction:Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:

    100 kVp Full wave rectified  

    Max. Continuous tube currentat 100 kVp:

    1.0 mA

    Inherent filtration/Window material:1.5 mm/Glass

    Cooling Method:

    High dielectric transformer oil

    SXR-90-15FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    20/58

    Pag

    SXR-90-15

  • 8/18/2019 Superior X-ray Tube Co.

    21/58

    Pag

    Operating Data

    Available focal spot sizes (mm):0.5

    Available target angles:

    15°

    Anode construction:Vacuum cast copper with tungsten target

    Cathode construction:

    Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:

    100 kVp Full wave rectified

    Max. Continuous tube currentat 100 kVp:

    1.0 mA

    Inherent filtration/Window material:1.5 mm/Glass

    Cooling Method:

    High dielectric transformer oil

    SXR-90-15M0.5 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    22/58

    Pag

    SXR-90-15M

  • 8/18/2019 Superior X-ray Tube Co.

    23/58

    Pag

    Operating Data

    Available focal spot sizes (mm):0.5

    Available target angles:

    15°

    Anode construction:Vacuum cast copper with tungsten target

    Cathode construction:

    Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:

    100 kVp Full wave rectified  

    Max. Continuous tube currentat 100 kVp:

    1.0 mA

    Inherent filtration/Window material:

    1.5 mm/Glass

    Cooling Method:

    High dielectric transformer oil

    SXR-90-15M20.5 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    24/58

    Pag

    SXR-90-15M2

  • 8/18/2019 Superior X-ray Tube Co.

    25/58

    Pag

    Operating Data

    Available focal spot sizes (mm):

    1.0

    Available target angles:15°

    Anode construction:

    Vacuum cast copper with tungsten target

    Cathode construction:Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:100 kVp Full wave rectified

    Max. Continuous tube currentat 100 kVp:1.5 mA

    Inherent filtration/Window material:

    1.5 mm/Glass

    Cooling Method:High dielectric transformer oil

    SXR-100-151.0 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    26/58

    Pag

    SXR-100-15 – 1.0 FOCAL SPOT 

    60Hz

    SXR-100-15 WITH SHIELD

  • 8/18/2019 Superior X-ray Tube Co.

    27/58

    Pag

    Operating Data

    Available focal spot sizes (mm):1.0

    Available target angles:

    25°

    Anode construction:Vacuum cast copper with tungsten targe

    Cathode construction:

    Vacuum tube nickel with tungsten filame

    Max. Tube operating voltage:

    100 kVp Full wave rectified  

    Max. Continuous tube currentat 100 kVp:

    1.5 mA

    Inherent filtration/Window material:1.5 mm/Glass

    Cooling Method:

    High dielectric transformer oil

    SXR-100-251.0 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    28/58

    Pag

    SXR-100-25 – 1.0 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    29/58

    Pag

    Operating Data

    Available focal spot sizes (mm):

    2.8

    Available target angles:20°

    Anode construction:

    Vacuum cast copper with tungsten target  

    Cathode construction:Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:125 kvp Full wave rectified  

    Max. Continuous tube currentat 100 kVp:3.0 mA

    Inherent filtration/Window material:

    1.5 mm/Glass

    Cooling Method:High dielectric transformer oil

    SXR-100-202.8 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    30/58

    Pag

    SXR-100-20

  • 8/18/2019 Superior X-ray Tube Co.

    31/58

    Pag

    Operating Data

    Available focal spot sizes (mm):

    2.0

    Available target angles:20°

    Anode construction:

    Vacuum cast copper with tungsten target  

    Cathode construction:Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:125 kvp Full wave rectified  

    Max. Continuous tube currentat 100 kVp:3.0 mA

    Inherent filtration/Window material:

    1.5 mm/Glass

    Cooling Method:High dielectric transformer oil

    SXR-100-20-22.0 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    32/58

    Pag

    SXR-100-20-2

    SXR-100-20-2 WITH SHIELD

  • 8/18/2019 Superior X-ray Tube Co.

    33/58

    Pag

    Operating Data

    Available focal spot sizes (mm):2.0

    Available target angles:

    45°

    Anode construction:Vacuum cast copper with tungsten target

    Cathode construction:

    Vacuum tube nickel with tungsten filamen

    Max. Tube operating voltage:125 kVp Full wave rectified  

    Max. Continuous tube currentat 125 kVp:3.0 mA

    Inherent filtration/Window material:

    1.5 mm/Glass

    Cooling Method:High dielectric transformer oil

    SXR-100-45 2.0 FOCAL SPOT 

  • 8/18/2019 Superior X-ray Tube Co.

    34/58

    Pag

    SXR-100-45

  • 8/18/2019 Superior X-ray Tube Co.

    35/58

    Pag

    Operating Data

    Available focal spot sizes (mm):1.5

    Available target angles:

    45°

    Anode construction:Vacuum cast copper with tungsten target

    Cathode construction:

    Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:

    125 kVp Full wave rectified

    Max. Continuous tube currentat 125 kVp:

    1.5 mA

    Inherent filtration/Window material:1.5 mm/Glass

    Cooling Method:

    High dielectric transformer oi 

    SXR-100-45M1.5 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    36/58

    Pag

    SXR-100-45M 

  • 8/18/2019 Superior X-ray Tube Co.

    37/58

    Pag

    Operating Data

    Available focal spot size (mm):

    0.2

    Available target angle:14°

    Anode construction:

    Vacuum cast copper with tungsten target

    Cathode construction:Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:

    50 kVp Full wave rectified

    Max. Continuous tube current at 50 kVp:

    1.0 mA

    Inherent filtration/Window material:.25 mm/Beryllium

    Cooling Method:

    High dielectric transformer oil

    Note:

    See Next Page for View A-A

    (Mounting flange)

    SXR-50-14-2BWP0.2 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    38/58

    Pag

    -  

    SXR-50-14-2BWP

    View A-A (Mounting Flange)

  • 8/18/2019 Superior X-ray Tube Co.

    39/58

    Pag

    Operating Data

    Available focal spot size (mm):1.0

    Available target angle:

    14°

    Anode construction:Vacuum cast copper with tungsten target

    Cathode construction:

    Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:

    50 kVp Full wave rectified

    Max. Continuous tube current at 50 kVp:1.2 mA

    Inherent filtration/Window material:

    .25 mm/Beryllium

    Cooling Method:High dielectric transformer oil

    Note:

    See Next Page for View A-A(Mounting flange)

    SXR-50-14-10BW1.0 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    40/58

    Pag

    SXR-50-14-10BWP

    View A-A (Mounting Flange)

  • 8/18/2019 Superior X-ray Tube Co.

    41/58

    Pag

    Operating Data

    Available focal spot size (mm):0.5

    Available target angle:

    20°

    Anode construction:Vacuum cast copper with tungsten target

    Cathode construction:

    Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:

    50 kVp Full wave rectified

    Max. Continuous tube current at 50 kVp:1.2 mA

    Inherent filtration/Window material:

    .25 mm/Beryllium

    Cooling Method:High dielectric transformer oil  

    Note:

    See Next Page for View A-A

    (Mounting flange)

    SXR-50-20-5BWP0.5 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    42/58

    Pag

    SXR-50-20-5BWP

    View A-A (Mounting Flange)

  • 8/18/2019 Superior X-ray Tube Co.

    43/58

    Pag

    Operating Data

    Available focal spot sizes (mm):0.2

    Available target angles:

    14°

    Anode construction:Vacuum cast copper with tungsten targ

    Cathode construction:

    Vacuum tube nickel with tungsten filam

    Max. Tube operating voltage:80 kVp Full wave rectified

    Max. Continuous tube currentat 80 kVp:

    0.60 mA

    Inherent filtration/Window material:.25 mm/Beryllium

    Cooling Method:

    High dielectric transformer oil

    Note:

    See Next Page for View A-A

    (Mounting flange)

    SXR-80-14-2BWP0.2 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    44/58

    Pag

    SXR-80-14-2BWP

    View A-A (Mounting Flange)

  • 8/18/2019 Superior X-ray Tube Co.

    45/58

    Pag

    Operating Data

    Available focal spot sizes (mm):

    1.0

    Available target angles:14°

    Anode construction:

    Vacuum cast copper with tungsten targ

    Cathode construction:Vacuum tube nickel with tungsten filam

    Max. Tube operating voltage:

    80 kVp Full wave rectified  

    Max. Continuous tube currentat 80 kVp:

    0.75 mA

    Inherent filtration/Window material:.25 mm/Beryllium

    Cooling Method:

    High dielectric transformer oil

    Note:

    See Next Page for View A-A

    (Mounting flange)

    SXR-80-14-10BWP1.0 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    46/58

    Pag

    SXR-80-14-10BWP

    View A-A (Mounting Flange)

  • 8/18/2019 Superior X-ray Tube Co.

    47/58

    Pag

    Operating Data

    Available focal spot size (mm):0.5

    Available target angle:

    20°

    Cathode construction:Vacuum tube nickel with tungstenfilament

    Anode construction:Vacuum cast copper with tungsten tar

    Max. Tube operating voltage:80 kVp Full wave rectified

    Max. Continuous tube currentat 80 kVp:0.70 mA

    Inherent filtration/Window material:

    .25 mm/Beryllium

    Cooling Method:High dielectric transformer oil

    Note:

    See Next Page for View A-A(Mounting flange)

    SXR-80-20-5BWP0.5 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    48/58

    Pag

    SXR-80-20-5BWP

    View A-A (Mounting Flange)

  • 8/18/2019 Superior X-ray Tube Co.

    49/58

    Pag

    Operating Data

    Available focal spot sizes (mm):

    0.5

    Available target angles:20°

    Anode construction:

    Vacuum cast copper with tungsten target

    Cathode construction:Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:

    60 kVp Full wave rectified  

    Max. Continuous tube current

    at 60 kVp:1.5 mA

    Inherent filtration/Window material:

    .75 mm/Beryllium

    Cooling Method:High dielectric transformer oil

    Note:See Next Page for View A-A(Mounting flange)

    SXR-212BW0.5 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    50/58

    Pag

    SXR-212BW

    View A-A (Mounting Flange)

    Type 1 Flange

    Type 2 Flange

  • 8/18/2019 Superior X-ray Tube Co.

    51/58

    Pag

    Operating Data

    Available focal spot sizes (mm):

    0.5

    Available target angles:20°

    Anode construction:

    Vacuum cast copper with tungsten target

    Cathode construction:Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:

    130 kVp Full wave rectified  

    Max. Continuous tube current

    at 130 kVp:1.0 mA

    Inherent filtration/Window material:

    .75 mm/Beryllium

    Cooling Method:High dielectric transformer oil

    Note:See Next Page for View A-A(Mounting flange)

    SXR-130-20-5BW0.5 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    52/58

    Pag

    SXR-130-20-5BW

  • 8/18/2019 Superior X-ray Tube Co.

    53/58

    Pag

    Operating Data

    Available focal spot sizes (mm):

    0.05

    Available target angles:25°

    Anode construction:

    Vacuum cast copper with tungsten target

    Cathode construction:Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:

    35 kVp Full wave rectified  

    Max. Continuous tube current

    at 35 kVp:300 uA

    Inherent filtration/Window material:

    .75 mm/Beryllium

    Cooling Method:Forced Air

    See Next Page for View A-A

    (Mounting flange)

    SXR-35-05BW0.05 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    54/58

    Pag

    SXR-35-05BW

    View A-A (Mounting Flange)

    Type 2 FlangeType 1 Flange

  • 8/18/2019 Superior X-ray Tube Co.

    55/58

    Pag

    Operating Data

    Available focal spot sizes (mm):0.05

    Available target angles:

    16°

    Anode construction:Vacuum cast copper with tungsten target

    Cathode construction:

    Vacuum tube nickel with tungsten filament

    Max. Tube operating voltage:80 kVp Full wave rectified  

    Max. Continuous tube currentat 80 kVp:

    300 uA

    Inherent filtration/Window material:.75 mm/Beryllium

    Cooling Method:

    High dielectric transformer oil

    Note:

    See Next Page for View A-A(Mounting flange)

    SXR-80-05BW0.05 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    56/58

    Pag

    SXR-80-05BW

    View A-A (Mounting Flange)

    Type 2 FlangeType 1 Flange

  • 8/18/2019 Superior X-ray Tube Co.

    57/58

    Pag

    Operating Data

    Available focal spot sizes (mm):0.05

    Available target angles:

    20°

    Anode construction:Vacuum cast copper with tungstentarget

    Cathode construction:Vacuum tube nickel with tungstenfilament

    Max. Tube operating voltage:

    130 kVp Full wave rectified  

    Max. Continuous tube currentat 130 kVp:

    300 uA

    Inherent filtration/Window mater.75 mm/Beryllium

    Cooling Method:

    High dielectric transformer oil

    Note:

    See Next Page for View A-A

    (Mounting flange)

    SXR-130-05BW0.05 FOCAL SPOT

  • 8/18/2019 Superior X-ray Tube Co.

    58/58

    Pag

    View A-A (Mounting Flange)

    T pe 2 Flange