summit x460 g2

26
Summit ® X460-G2 Gigabit Core Top of the Rack Advanced Edge Metro aggregation

Upload: muk-extreme

Post on 25-Jul-2015

521 views

Category:

Engineering


5 download

TRANSCRIPT

Page 1: Summit x460 g2

Summit® X460-G2

Gigabit Core Top of the Rack Advanced Edge

Metro aggregation

Page 2: Summit x460 g2

2

X460 решение для всех вертикалей рынка

Virtualized Data Center

Summit X460Summit X480

Wir

ed

Converged Campus

Summit X430 Summit X440

Secure Mobile Edge

E4G-Series

Growth Service Provider

BlackDiamond 8000

IdentiFi Controllers

IdentiFi Access Points

Wir

eles

s

Multi-Tenant Enterprise / IT

IXPMobile Backhaul

Clo

ud

Summit X670

Summit X770

BlackDiamond X8

HPC

ISP

Mo

bil

ity

XOS

SDN

Metro / Campus / DC Interconnect

Leno

voSG

IEM

CEr

icsso

n

Control Center

Page 3: Summit x460 g2

Позиционирование гигабитной линейки Summit

X430 Series

X440Series

X460Series

Edge or core of large enterprise & SP access or aggregation

AC/DC PSUs

DC for 1GbE to 10GbE transition

1500W POE+

Reverse Air Flow

Timing & OAM

160Gbps Stacking

100 - 500 user network

Edge of large enterprise

SMB, enterprise edge or campus

40Gbps Stacking

<100 user network

SMB, Campus, open environment

Standalone(L2 Only)

Stackable(L3 Edge)

X450

Series

500+ user network

Edge or core of large enterprise

Power redundancy

High POE+ Budget

80 Gbps Stacking

Stackable(L3 Advanced Edge)

Stackable(L3 Core & MPLS)

X480

Series

Edge or core of large enterprise & SP access or aggregation

AC/DC PSUs

DC for 1GbE to 10GbE transition

512K TCAM for tables sizes

320Gbps Stacking

Stackable(L3 Core & MPLS)

Page 4: Summit x460 g2

Обзор Summit X460-G2

Page 5: Summit x460 g2

©2014 Extreme Networks, Inc. All rights reserved. 5

Семейство Summit X460-G2

Page 6: Summit x460 g2

6

X460-G2 Base модели с 10GbE аплинками

-24t

-48t

-24p

-48p

-24x

-48x

Комбо-порты только в моделях с 24

портами

Блоки питания, вентиляторы, Timing модуль и VIM модули поставляются отдельно

Page 7: Summit x460 g2

7

Summit X460-G2 набор портов передней панели

Copper GE

Ports(RJ-45)

Fiber GE

Ports(SFP)

Shared GE

Ports

Native

10 GE Ports

(SFP+)

Active GE

Ports UsingSFP / SFP+

X460-G2-24t-10GE4 24 8 4 4 28 / 32

X460-G2-48t-10GE4 48 0 0 4 48 / 52

X460-G2-24p-10GE4 24 8 4 4 28 / 32

X460-G2-48p-10GE4 48 0 0 4 48 / 52

X460-G2-24x-10GE4 8 24 4 4 28 / 32

X460-G2-48x-10GE4 0 48 0 4 48 / 52

Energy Efficient Ethernet (EEE) поддерживается на всех медных

Base-T портах включая 10GBase-T VIM модуль

Page 8: Summit x460 g2

8

Блоки питания, вентиляторы, Timing модуль и VIM модули поставляются отдельно

X460-G2 Base модели с 1Gb аплинками

Комбо-порты только в моделях

с 24 портами

-24t

-48t

-24p

-48p

Page 9: Summit x460 g2

9

Summit X460-G2 набор портов передней панели

Copper GE Ports

(RJ-45)

Fiber GE Ports(SFP)

Shared GE Ports

Native 10 GE Ports

(SFP+)

Active GE Ports UsingSFP

X460-G2-24t-GE4 24 12 4 0 32

X460-G2-48t-GE4 48 4 0 0 52

X460-G2-24p-GE4 24 12 4 0 32

X460-G2-48p-GE4 48 4 0 0 52

Page 10: Summit x460 g2

X460-G2 Switches Back Panel Components

10

Опционально: Timing модуль для SyncE и 1588 PTP

поставляется отдельно

Опционально:VIM модули

поставляются отдельно

Рекомендовано:Блок

вентиляторов с направлением

потоков воздухапоставляются

отдельно

Опционально:Резервный Блок

питания с направлением

потоков воздухапоставляются

отдельно

Рекомендовано: Первый Блок

питания с направлением

потоков воздухапоставляются

отдельно

X460-G2 обзор задней панели

Блоки питания, вентиляторы, Timing модуль и VIM модули поставляются отдельно

Поставляются пустыми

Поставляются с заглушками для 1

слота БП, VIM слота и слота для

Timing модуля

Page 11: Summit x460 g2

X460-G2 VIMs

11

• VIM модули и TM не могут быть использованы в старых Summit X460• Summit X460-G2 VIM-2q не поддерживают разделение на 10GbE порты

*FUTURE AVAILABILITY – SUBJECT TO CHANGE

X460-G2 опциональные модули расширения

Summit X460-G2 VIM-2q Опциональный Virtual Interface Module предоставляющий 2 40GBASE-X выделенных QSFP+ порта

Summit X460-G2 VIM-2x Опциональный Virtual Interface Module предоставляющий 2 10GBASE-X выделенных SFP+ порта

Summit X460-G2 VIM-2t Опциональный Virtual Interface Module предоставляющий 2 10GBASE-T порта

Summit X460-G2 VIM-2ss Опциональный Virtual Interface Module предоставляющий 2 порта стекирования Extreme SummitStack

Summit X460-G2 TM-CLK

Опциональный Timing Module предоставляющий возможность SyncE и 1588 PTP clocking имеющий 2 mini-BNC коннектора для clocking outputs

Page 12: Summit x460 g2

12

Summit X460-G2 набор портов передней панели

Model Copper GE Ports

(RJ-45)

Fiber GE Ports(SFP)

Shared GE Ports

Native 10 GE Ports

(SFP+)

Active GE Ports UsingSFP / SFP+

X460-G2-24t-10GE4 24 8 4 4 28 / 32

X460-G2-48t-10GE4 48 0 0 4 48 / 52

X460-G2-24p-10GE4 24 8 4 4 28 / 32

X460-G2-48p-10GE4 48 0 0 4 48 / 52

X460-G2-24x-10GE4 8 24 4 4 28 / 32

X460-G2-48x-10GE4 0 48 0 4 48 / 52

X460-G2-24t-GE4 24 12 4 0 32 / 32

X460-G2-48t-GE4 48 4 0 0 52 / 52

X460-G2-24p-GE4 24 12 4 0 32 / 32

X460-G2-48p-GE4 48 4 0 0 52 / 52

Page 13: Summit x460 g2

13

Максимальный набор портов с 1 VIM модулем

Model Copper GE Ports

(RJ-45)

Using Cu GBICs

Fiber GE Ports(SFP)

Fiber 10 GE Ports

(SFP+)

Cannot fanout QSFP+

Copper 10 GE Ports (RJ-45)

40GE Ports (QSFP+)

X460-G2-24t-10GE4 34 14 6 2 2

X460-G2-48t-10GE4 54 6 6 2 2

X460-G2-24p-10GE4 34 14 6 2 2

X460-G2-48p-10GE4 54 6 6 2 2

X460-G2-24x-10GE4 34 30 6 2 2

X460-G2-48x-10GE4 54 54 6 2 2

X460-G2-24t-GE4 34 14 2 2 2

X460-G2-48t-GE4 54 6 2 2 2

X460-G2-24p-GE4 34 14 2 2 2

X460-G2-48p-GE4 54 6 2 2 2

Page 14: Summit x460 g2

14

Summit X460-G2 - Мощность

Model SwitchMax

Power Draw (W)

Max PoE+

Budget715W PSUs (W)

Max PoE+

Budget1100W PSUs (W)

AC & DC

PSUs

ModularRedun-

dant PSU

Mix AC & DC PSUs

FB & BF

Airflow Options

for PSUs

X460-G2-24t-10GE4 125

X460-G2-48t-10GE4 125

X460-G2-24p-10GE4 204 1031 1668

X460-G2-48p-10GE4 334 1031 1668

X460-G2-24x-10GE4 125

X460-G2-48x-10GE4 125

X460-G2-24t-GE4 125

X460-G2-48t-GE4 125

X460-G2-24p-GE4 204 1031 1668

X460-G2-48p-GE4 334 1031 1668

Page 15: Summit x460 g2

15

Summit X460-G2 Температура и уровни шума

Models TempRange

Acoustic Nose @ 25⁰C (dB)

Acoustic Nose @ 35⁰C (dB)

Acoustic Nose @ 50⁰C (dB)

2 PSU1 VIM

F-B Flow

2 PSU1 VIM

B-F Flow

2 PSU1 VIM

F-B Flow

2 PSU1 VIM

B-F Flow

2 PSU1 VIM

F-B Flow

2 PSU1 VIM

6 Uplinks

X460-G2-24t-10GE4 0-50 C⁰ 49.1 48.9 49.1 48.9 54.9 65.6

X460-G2-48t-10GE4 0-50 C⁰ 47.6 47.7 47.6 47.7 64.5 65.3

X460-G2-24p-10GE4 0-50 C⁰ 52.2 50.8 52.2 50.8 61.8 69.8

X460-G2-48p-10GE4 0-50 C⁰ 52.2 50.9 52.2 64.2 64.3 70.8

X460-G2-24x-10GE4 0-50 C⁰ 48.8 48.8 48.8 48.8 61.9 66.7

X460-G2-48x-10GE4 0-50 C⁰ 48.9 48.8 48.9 48.8 60.5 66.1

X460-G2-24t-GE4 0-50 C⁰ 49.1 48.9 49.1 48.9 54.9 65.6

X460-G2-48t-GE4 0-50 C⁰ 47.6 47.7 47.6 47.7 64.5 65.3

X460-G2-24p-GE4 0-50 C⁰ 52.2 50.8 52.2 50.8 61.8 69.8

X460-G2-48p-GE4 0-50 C⁰ 52.2 50.9 52.2 64.2 64.3 70.8

Page 16: Summit x460 g2

16

Summit® X460-G2 - Вес и размеры

Model Weight (lb / kg)

Height(in / cm)

Width (in / cm)

Depth(in / cm)

X460-G2-24t-10GE4 12.86 5.83 1.73 4.4 17.4 44.1 16.94 37.3

X460-G2-48t-10GE4 13.27 6.02 1.73 4.4 17.4 44.1 16.94 37.3

X460-G2-24p-10GE4 14.68 6.66 1.73 4.4 17.4 44.1 19.11 42.1

X460-G2-48p-10GE4 15.21 6.90 1.73 4.4 17.4 44.1 19.11 42.1

X460-G2-24x-10GE4 13.13 5.96 1.73 4.4 17.4 44.1 16.94 37.3

X460-G2-48x-10GE4 13.62 6.18 1.73 4.4 17.4 44.1 16.94 37.3

X460-G2-24t-GE4 12.86 5.83 1.73 4.4 17.4 44.1 16.94 37.3

X460-G2-48t-GE413.27 6.02

1.73 4.4 17.4 44.116.94 37.3

X460-G2-24p-GE4 14.68 6.66 1.73 4.4 17.4 44.1 19.11 42.1

X460-G2-48p-GE4 15.21 6.90 1.73 4.4 17.4 44.1 19.11 42.1

X460-G2 VIM-2q 0.57 0.26 1.40 3.1 3.39 7.5 5.49 12.1

X460-G2 VIM-2x 0.57 0.26 1.40 3.1 3.39 7.5 5.49 12.1

X460-G2 VIM-2t 0.57 0.26 1.40 3.1 3.39 7.5 5.49 12.1

X460-G2 VIM-2ss 0.57 0.26 1.40 3.1 3.39 7.5 5.49 12.1

X460-G2 TM-CLK 0.19 0.09 1.64 3.6 0.87 1.9 6.29 13.9

Page 17: Summit x460 g2

©2014 Extreme Networks, Inc. All rights reserved. 17

Сравнение X460-G2 и X460

Feature X460-G2 X460

Front 10Gb порты 4* Нет

40GbE Uplinks Да Нет

Front to Back Cooling Да Да

Back to Front Cooling Да Нет

PoE+ Power – 1 PSU 850 watts 380 watts

PoE+ Power – 2 PSUs 1668 watts 760 watts

10GBase-T аплинки 2 via VIM Нет

IPFIX Да Да

Synch Ethernet Да Только SFP модели

1588 Precision Timing Protocol

Да Нет

Y.1731 OAM in Hardware Да Нет

Опции стекированияSummitStack VIM,

10GbE передней панели, 40GbE VIM

SummitStack VIM, 10GbE VIM,

SummitStack-V80 VIM

Max 10GbE портов 6^ 6

* У моделей с 10Gb аплинками ^ 40GbE порты НЕ МОГУТ быть расшиты в 4 x 10GbE

Page 18: Summit x460 g2

Summit X460-G2 сравнение

18

Metric Summit X440 Summit X460 Summit X460-G2

L2 MAC 16K 32K 176K

L3L3 Hash IPv4 Unicast

512 16K 176K

L3 Hash IPv6 Unicast

256 4K 88K

IPv4 LPM 64 12K 12K

IPv6 LPM 32 6K 6K

IP multicast groups 64 4K 4K

IP-multicast (s,v,g) entries

1K 6K 24K

ECMP --- 2K 4K

L3 Interfaces 256 512 512

Security Ingress ACL 1K 4K 4K

Egress ACL No 512 1K

UFT

Page 19: Summit x460 g2

Summit X460 – Лицензирование

19

Advanced Edge

Edge

Upg

rade

opt

ions

Layer 2 switching with Layer 2-Layer 4 QoS, EAPS-edge, STP, RSTP, PVST+, 802.1s, etc.Basic Layer 3 routing capability for IPv4/IPv6 with RIPv1, v2, RIPng

Advanced Edge Feature, sFlow, etc.OSPF-edge, PIM-SM-edge, VRRP, ESRP, etc.

CoreEAPSv2, PIM-DM, IPv6 with IS-IS, BGPv4, OSPFv3, Multicast Source Discovery Protocol (MSDP) etc.

Дефолт для всех моделей

Direct Attach AVB MPLS OpenFlow

Page 20: Summit x460 g2

©2014 Extreme Networks, Inc. All rights reserved. 20

• Гетерогенное стекирование• Пропускная способность V160 стекированияСтекирование

• 40 GbE аплинки на GE коммутаторе• Размеры внутренних таблицУлучшение

• MPLS, AVB, SDN OpenFlow, Y.1731, BFD, EEE, SyncE и 1588 PTP Возможности

• Конкурентоспособная цена относительно производительностиЦена/Производительность

• Использование Y.1731 для µs задержки & jitter SLAs• 1588 PTP и SyncE для синхронизацииTiming

Конкурентные примущества

Page 21: Summit x460 g2

Возможности стекирования

21

Page 22: Summit x460 g2

22

Summit X460-G2 опции стекирования

SummitStack™ (VIM-2ss модуль) •40 Gbps пропускная способность стека

•Совместимость со всеми свитчами Summit®

•Summit X440, X460, X460-G2 и X480

Stacking modules and 10 GbE module must be ordered separatelyPassive Copper

Active Fiber

Optics + MTP Cable

SummitStack-V (SFP+ порты передней панели)•Последние два 10Gb порта (т.е. 51 & 52 или 31 & 32)

•40Gbps пропускная способность стека

•На расстоянии до 40 km

•Совместимость со всеми свитчами Summit® с SFP+ стеком

•Summit X440, X460, X460-G2, X480, X670, X670-G2 и X770

SummitStack-V160 (VIM-2q модуль) • 160Gbps пропускная способность стека

• На расстоянии до 40 km

• Совместимость со всеми свитчами Summit® с QSFP+ стеком

• Summit X460-G2, X480, X670V, X670-G2 и X770

CX4 Copper

Page 23: Summit x460 g2

23

Матрица Summit стекирования

Коннект между X440 X440-10G X460 X460-G2 X480 X670 X670V X670-G2 X770

X440 CX4 - CX4 CX4 CX4 - - - -

X440-10G - V V V V V V V V

X460 CX4 V CX4, V, V80 CX4, V CX4, V, V80 V V, V80 V, V80 V

X460-G2 CX4 V CX4, V CX4, V, V160 CX4, V, V160 V V, V160 V, V160 V, V160

X480 CX4 V CX4, V, V80 CX4, V, V160CX4, V, V80, V160, V320

VV, V80, V160,

V320V, V160, V320 V, V160, V320

X670 - V V V V V V V V

X670V - V V, V80 V, V160V, V80, V160,

V320V

V, V80, V160, V320

V, V80, V160, V320

V, V160, V320

X670-G2 - V V, V80 V, V160 V, V160, V320 VV, V80, V160,

V320V, V80, V160,

V320V, V160, V320

X770 - V V V, V160 V, V160, V320 V V, V160, V320 V, V160, V320 V, V160, V320

KEY:CX4 SummitStack CX4V SummitStack-V 10GbEV80 SummitStack-V80 QSFP+ (2 Lanes)V160 SummitStack-V160 QSFP+ (1 port)V320 SummitStack-V320 QSFP+ (2 ports)

Page 24: Summit x460 g2

24

Стекирование в ЦОД

SummitStack-V, V80, V160 предлагает– Большую пропускную способность стека до 160Gbps– Гибкость соединения используя SFP+/QSFP+ технологию

• Over Standard SMF/MMF• Over Passive Copper• Over Active Fiber

– Короткие и длинные расстояния– До 40km Passive Copper

Active Fiber

Page 25: Summit x460 g2

25

Stack distance up to 40 km

Summit X460-G2 in

Campus Core using SummitStack

technology

Summit X460-G2 in

Campus Edgeadvanced

edge switching with PoE-plus

in the wiring closet

Distributed Stacking

Стекирование в Campus/Enterprise

Stack distance up to 40 km

Distributed Stacking

CAMPUS CORE

CAMPUS EDGE

MLAG

Page 26: Summit x460 g2

Паливода Александр[email protected]