summary of reactor unit status at 18 march - graham andrew

4
IAEA International Atomic Energy Agency Presentation by Graham Andrew Special Assistant to the DG for Scientific & Technical Affairs March 18 th 2011

Upload: international-atomic-energy-agency

Post on 03-Aug-2015

18.446 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Summary of reactor unit status at 18 March - Graham Andrew

IAEAInternational Atomic Energy Agency

Presentation by

Graham AndrewSpecial Assistant to the DG for Scientific & Technical Affairs

March 18th 2011

Page 2: Summary of reactor unit status at 18 March - Graham Andrew

Unit 1 2 3 4

Power (MWe/th) 460/1380 784/2381 784/2381 784/2381

Type of Reactor BWR-3 BWR-4 BWR-4 BWR-4

Status at time of EQ In service – auto shutdown

In service – auto shutdown

In service – auto shutdown

Outage

Core and fuel Damaged Damaged Damaged No fuel rods

RPV & RCS integrity Unknown Unknown Unknown N/A

Containment integrityNo damage reported

Damage suspected

No information N/A

AC Power Not availableRecovery is on-going

Not available Not available

Building Severe damage Slight damage Severe damage Severe damage

Water level of RPVAround half of Fuel assembly

Around half of Fuel assembly

Around half of Fuel assembly

N/APressure of RPV Stable Unreliable data Stabilized

CV Pressure Drywell Unknown Stable Stable

Water injection to RPV Seawater Seawater Seawater N/A

Water injection to CV Not available Not available Not available N/A

Spent Fuel Pool No information No information No information No information04/15/23 05:53

Page 3: Summary of reactor unit status at 18 March - Graham Andrew

Unit 5 6

Power 784/2381 1100/3293

Type of Reactor BWR-4 BWR-5

Status at the EQ occurred

Outage Outage

Core and Fuel No damage expected No Damage expected

Containment int. No damage expected No damage expected

AC Power 1 Emergency DieselFrom unit 6

Emergency Diesel

Building No damage reported No damage reported

Water level of RPV Above fuel Above fuel

Pressure of RPV No information No information

Containment Pressure No information No information

Water injection to RPV Not necessary Not necessary

Water injection to CV Not necessary Not necessary

Spent Fuel Pool Temperature

Slightly increasing Stabilised

Date : March 18 Time : UTC

Severe condition

Concern

No immediate concern

Reporting time:

04/15/23 05:53

Page 4: Summary of reactor unit status at 18 March - Graham Andrew

IAEA

INES rating, March 18

• Fukushima Daiichi Units 1, 2 and 3 - INES 5• core damage caused by the loss of all cooling

function

• Fukushima Daiichi Unit 4 – INES 3• cooling and water supply in the spent fuel pool have

been lost

• Fukushima Daini Units 1, 2 and 4 – INES 3• loss of cooling functions