submittal review - pavilion construction · submittal not requested/returned without review...

43
Submittal Review TO: Pavilion Construction DATE: 07.13.2015 JOB NO.: 1484P 4700 SW Macadam Ave Suite 200 ATTENTION: Riley Tobin Portland, OR 97239 RE: BSD Sunset High School Concession Stand/Interior Renovations Package 1 Submittal: 105113 Metal Lockers Approved Approved As Noted Revise as Noted/Resubmit Rejected/Resubmit As Specified No Action Required Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in the Contract Documents. Contractor is responsible for quantities and dimensions to be confirmed and correlated; for fabrication process; for means methods, techniques, sequences and procedures of construction; for coordination of the Work; and for all safety aspects of performing the Work. Approval does not modify the Contract Documents and approval of a specific item does not indicate approval of an assembly of which the item is a component. Specification Section Title Notation 105113 1.4A Product Data Approved as Noted 105113 1.4B Shop Drawings Approved as Noted 105113 1.4C Samples For Each Color Selected Approved as Noted. See note 4 105113 1.4D Samples For Initial Selection Approved as Noted. 105113 1.4E Samples For Verification Not Submitted. Resubmit 105113 1.4 F Product Schedule Reviewed in Submittal 3 - 10 51 13 - 0 105113 1.5A Qualification Data Reviewed in Submittal 4 - 10 51 13 - 0 105113 1.5B Sample Warranty Reviewed in Submittal 4 - 10 51 13 - 0 Summary Comments: 1. G.C. to verify all dimensions and Locations. 2. See the attached pdf for additional comments. 3. Beaverton School District has selected color #706 Heather. 4. Locker type “B” K.D. construction is acceptable per Jessica Faust of BSD. 5. See previous locker submittal for approved numbering scheme. 6. See page # “SB-2301-2” for comment on filler panel dimensions. 1001 SW 5 th Ave. // Suite 1100 // Portland // OR 97204-1127 // P: 503.535.0707 // www.blrb.com

Upload: others

Post on 07-Apr-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Submittal Review

TO: Pavilion Construction DATE: 07.13.2015 JOB NO.: 1484P 4700 SW Macadam Ave Suite 200 ATTENTION: Riley Tobin Portland, OR 97239 RE: BSD Sunset High School

Concession Stand/Interior Renovations Package 1

Submittal: 105113 Metal Lockers

Approved Approved As Noted Revise as Noted/Resubmit Rejected/Resubmit As Specified No Action Required Submittal Not Requested/Returned Without Review

Approval is for conformance with information given and the design concept expressed in the Contract Documents. Contractor is responsible for quantities and dimensions to be confirmed and correlated; for fabrication process; for means methods, techniques, sequences and procedures of construction; for coordination of the Work; and for all safety aspects of performing the Work. Approval does not modify the Contract Documents and approval of a specific item does not indicate approval of an assembly of which the item is a component.

Specification Section Title Notation 105113 1.4A Product Data Approved as Noted

105113 1.4B Shop Drawings Approved as Noted

105113 1.4C Samples For Each Color Selected Approved as Noted. See note 4

105113 1.4D Samples For Initial Selection Approved as Noted.

105113 1.4E Samples For Verification Not Submitted. Resubmit

105113 1.4 F Product Schedule Reviewed in Submittal 3 - 10 51 13 - 0

105113 1.5A Qualification Data Reviewed in Submittal 4 - 10 51 13 - 0

105113 1.5B Sample Warranty Reviewed in Submittal 4 - 10 51 13 - 0

Summary Comments:

1. G.C. to verify all dimensions and Locations. 2. See the attached pdf for additional comments. 3. Beaverton School District has selected color #706 Heather. 4. Locker type “B” K.D. construction is acceptable per Jessica Faust of BSD. 5. See previous locker submittal for approved numbering scheme. 6. See page # “SB-2301-2” for comment on filler panel dimensions.

1001 SW 5th Ave. // Suite 1100 // Portland // OR 97204-1127 // P: 503.535.0707 // www.blrb.com

Page 2: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School 13840 NW Cornell Rd.

Portland, OR 97229

Pavilion Construction NW, LLC 4700 SW Macadam Ave. Portland, OR 97239 Phone: (503)290-5005 Fax: (503)244-1810 www.pavilionconstruction.com Page 1 of 1

To: BLRB ARCHITECTS, P.S. Date: 07/09/2015

Attn: RICHARD HIGGINS

1001 SW 5TH AVE., SUITE 1100 Contact Phone: 503-535-0707

PORTLAND, OR 97204 Contact Email: [email protected]

CC’d:

SUBMITTAL TRANSMITTAL FOR APPROVAL

Submittal #: 42 Rev.#: 1 In Accordance with Specification Section #: 105113

This is a submittal for Metal Lockers items per the table below as reviewed and noted by Pavilion Construction NW, LLC, and provided by . Please provide a response to this submittal by 07/13/2015.

Pavilion Status: Sent/Submitted

Notes:

Submitted By: Riley Tobin Phone: (503)290-5005

Email Address: [email protected] Fax: (503)244-1810

SUBMITTAL RESPONSE

Architect’s Response Schedule Tracking Proceed Date Received from Sub/Sup 07/09/2015

Proceed, as noted Date Requested to be returned 07/13/2015

Revise and Resubmit Date Returned from Architect

Material Return without Review Date Returned to Sup/Sup

Comments:

rtobin
Submittal Review
rtobin
Accepted
rtobin
Text Box
Riley Tobin
rtobin
Text Box
7/9/15
mharmel
New Stamp
mharmel
Line
mharmel
Line
mharmel
Line
mharmel
Line
mharmel
Text Box
Mike Harmel
mharmel
Text Box
07.13.2015
Page 3: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School - Title IX and Upgrades Beaverton School District No. 48 BLRB Project No.: 14.84P

Permit Set May 15, 2015

BLRB Architects - Portland, Oregon METAL LOCKERS 10 51 13 - 1

SECTION 10 51 13 - METAL LOCKERS

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

1.2 SUMMARY

A. Section Includes: 1. Knocked-down athletic lockers. 2. Welded athletic lockers.

1.3 PREINSTALLATION MEETINGS

A. Preinstallation Conference: Conduct conference at Project site.

1.4 ACTION SUBMITTALS

A. Product Data: For each type of metal locker. 1. Include construction details, material descriptions, dimensions of individual components and

profiles, and finishes for each type of metal locker.

B. Shop Drawings: For metal lockers. 1. Include plans, elevations, sections, details, and attachments to other work. 2. Show locker trim and accessories. 3. Include locker identification system and numbering sequence.

C. Samples: For each color specified, in manufacturer's standard size.

D. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

E. Samples for Verification: For the following products, in manufacturer's standard size: 1. Lockers and equipment. 2. Locker benches.

F. Product Schedule: For lockers.

1.5 INFORMATIONAL SUBMITTALS

A. Qualification Data: For Installer.

B. Sample Warranty: For special warranty.

rtobin
Text Box
Pages 12-15
rtobin
Text Box
Pages 11-15
rtobin
Text Box
Color Chain Hand Delivered at 6/30/15 OAC Meeting
rtobin
Text Box
See layout drawing for quantities of each type
rtobin
Text Box
Lockers will be numbered consecutivly from 1-x by room
rtobin
Rectangle
rtobin
Text Box
Installation instruction on page 22
Page 4: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School - Title IX and Upgrades Beaverton School District No. 48 BLRB Project No.: 14.84P

Permit Set May 15, 2015

BLRB Architects - Portland, Oregon METAL LOCKERS 10 51 13 - 2

1.6 CLOSEOUT SUBMITTALS

A. Maintenance Data: For adjusting, repairing, and replacing locker doors and latching mechanisms to include in maintenance manuals.

1.7 MAINTENANCE MATERIAL SUBMITTALS

A. Furnish extra materials that match products installed and that are packaged with protective covering for storage and identified with labels describing contents. 1. Full-size units of the following metal locker hardware items equal to 10 percent of amount

installed for each type and finish installed, but no fewer than five units: 2. Locks.

a. Identification plates. b. Hooks.

1.8 DELIVERY, STORAGE, AND HANDLING

A. Do not deliver metal lockers until spaces to receive them are clean, dry, and ready for their installation.

1.9 FIELD CONDITIONS

A. Field Measurements: Verify actual dimensions of recessed openings by field measurements before fabrication.

1.10 COORDINATION

A. Coordinate sizes and locations of concrete bases for metal lockers.

B. Coordinate sizes and locations of framing, blocking, furring, reinforcements, and other related units of work specified in other Sections to ensure that metal lockers can be supported and installed as indicated.

1.11 WARRANTY

A. Special Warranty: Manufacturer agrees to repair or replace components of metal lockers that fail in materials or workmanship, excluding finish, within specified warranty period. 1. Failures include, but are not limited to, the following:

a. Structural failures. b. Faulty operation of latches and other door hardware.

2. Damage from deliberate destruction and vandalism is excluded. 3. Warranty Period for Knocked-Down Metal Lockers: Two years from date of Substantial

Completion. 4. Warranty Period for Welded Metal Lockers: Lifetime from date of Substantial Completion.

Page 5: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School - Title IX and Upgrades Beaverton School District No. 48 BLRB Project No.: 14.84P

Permit Set May 15, 2015

BLRB Architects - Portland, Oregon METAL LOCKERS 10 51 13 - 3

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. Source Limitations: Obtain metal lockers and accessories from single source from single locker manufacturer. 1. Obtain locks from single lock manufacturer.

2.2 PERFORMANCE REQUIREMENTS

A. Accessibility Requirements: For lockers indicated to be accessible, comply with applicable provisions in the U.S. Architectural & Transportation Barriers Compliance Board's ADA-ABA Accessibility Guidelines and ICC A117.1.

2.3 KNOCKED-DOWN ATHLETIC LOCKERS

A. Basis-of-Design Product: Subject to compliance with requirements, provide Republic Storage Systems, LLC; Heavy Duty Ventilated or a comparable product by one of the following: 1. Art Metal Products. 2. Lyon Workspace Products, LLC. 3. Penco Products, Inc.

B. Perforated Doors: One piece; fabricated from 0.075-inch nominal-thickness steel sheet with manufacturer's standard diamond perforations; formed into channel shape with double bend at vertical edges and with right-angle single bend at horizontal edges and latch point (bottom) and right-angle single bend at remaining edges for box lockers. 1. Reinforcement: Manufacturer's standard reinforcing angles, channels, or stiffeners for doors

more than 15 inches wide; welded to inner face of doors.

C. Body: Assembled by riveting or bolting body components together. Fabricate from unperforated steel sheet with thicknesses as follows: 1. Tops and Bottoms: 0.060-inch nominal thickness, with single bend at edges. 2. Backs: 0.048-inch nominal thickness. 3. Shelves: 0.060-inch nominal thickness, with double bend at front and single bend at sides and

back.

D. Unperforated Sides: Fabricated from 0.060-inch nominal-thickness steel sheet.

E. Frames: Channel formed; fabricated from 0.060-inch nominal-thickness steel sheet or 0.097-inch nominal-thickness steel angles; lapped and factory welded at corners; with top and bottom main frames factory welded into vertical main frames. Form continuous, integral, full-height door strikes on vertical main frames. 1. Cross Frames for Double-Tier and Triple-Tier Lockers: Channel formed and fabricated from

same material as main frames; welded to vertical main frames.

F. Hinges: Welded to door and attached to door frame with no fewer than two factory-installed rivets per hinge that are completely concealed and tamper resistant when door is closed; fabricated to swing 180 degrees. 1. Knuckle Hinges: Steel, full loop, five or seven knuckles, tight pin; minimum 2 inches high.

Provide no fewer than three hinges for each door more than 42 inches high.

Page 6: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School - Title IX and Upgrades Beaverton School District No. 48 BLRB Project No.: 14.84P

Permit Set May 15, 2015

BLRB Architects - Portland, Oregon METAL LOCKERS 10 51 13 - 4

G. Door Handle and Latch: Stainless-steel strike plate with integral pull; with steel padlock loop that projects through metal locker door.

H. Identification Plates: Manufacturer's standard, etched, embossed, or stamped aluminum plates, with numbers and letters at least 3/8 inch high.

I. Hooks: Manufacturer's standard ball-pointed type, aluminum or steel; zinc plated.

J. Coat Rods: Manufacturer's standard.

K. Continuous Sloping Tops: Fabricated from 0.048-inch nominal-thickness steel sheet, with a pitch of approximately 20 degrees. 1. Closures: Vertical-end type.

L. Filler Panels: Fabricated from 0.048-inch nominal-thickness steel sheet.

M. Boxed End Panels: Fabricated from 0.060-inch nominal-thickness steel sheet.

N. Materials: 1. Cold-Rolled Steel Sheet: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B, suitable for

exposed applications.

O. Finish: Baked enamel or powder coat. 1. Color: As selected by Architect from manufacturer's full range.

2.4 WELDED ATHLETIC LOCKERS

A. Basis-of-Design Product: Subject to compliance with requirements, provide Republic Storage Systems, LLC; All-Welded Ventilated or a comparable product by one of the following: 1. Art Metal Products. 2. Lyon Workspace Products, LLC. 3. Penco Products, Inc.

B. Perforated Doors: One piece; fabricated from 0.075-inch nominal-thickness steel sheet with manufacturer's standard diamond perforations; formed into channel shape with double bend at vertical edges and with right-angle single bend at horizontal edges and latch point (bottom) and right-angle single bend at remaining edges for box lockers. 1. Reinforcement: Manufacturer's standard reinforcing angles, channels, or stiffeners for doors

more than 15 inches wide; welded to inner face of doors.

C. Body: Assembled by welding body components together. Fabricate from unperforated steel sheet with thicknesses as follows: 1. Tops and Bottoms: 0.060-inch nominal thickness, with single bend at edges. 2. Backs: 0.048-inch nominal thickness. 3. Shelves: 0.060-inch nominal thickness, with double bend at front and single bend at sides and

back.

D. Unperforated Sides: Fabricated from 0.060-inch nominal-thickness steel sheet.

E. Frames: Channel formed; fabricated from 0.060-inch nominal-thickness steel sheet or 0.097-inch nominal-thickness steel angles; lapped and factory welded at corners; with top and bottom main frames factory welded into vertical main frames. Form continuous, integral, full-height door strikes on vertical main frames.

Page 7: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School - Title IX and Upgrades Beaverton School District No. 48 BLRB Project No.: 14.84P

Permit Set May 15, 2015

BLRB Architects - Portland, Oregon METAL LOCKERS 10 51 13 - 5

1. Cross Frames for Double-Tier and Triple-Tier Lockers: Channel formed and fabricated from same material as main frames; welded to vertical main frames.

F. Hinges: Welded to door and attached to door frame with no fewer than two factory-installed rivets per hinge that are completely concealed and tamper resistant when door is closed; fabricated to swing 180 degrees. 1. Knuckle Hinges: Steel, full loop, five or seven knuckles, tight pin; minimum 2 inches high.

Provide no fewer than three hinges for each door more than 42 inches high.

G. Door Handle and Latch: Stainless-steel strike plate with integral pull; with steel padlock loop that projects through metal locker door.

H. Identification Plates: Manufacturer's standard, etched, embossed, or stamped aluminum plates, with numbers and letters at least 3/8 inch high.

I. Hooks: Manufacturer's standard ball-pointed type, aluminum or steel; zinc plated.

J. Coat Rods: Manufacturer's standard.

K. Continuous Sloping Tops: Fabricated from 0.048-inch nominal-thickness steel sheet, with a pitch of approximately 20 degrees. 1. Closures: Vertical-end type.

L. Filler Panels: Fabricated from 0.048-inch nominal-thickness steel sheet.

M. Boxed End Panels: Fabricated from 0.060-inch nominal-thickness steel sheet.

N. Materials: 1. Cold-Rolled Steel Sheet: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B, suitable for

exposed applications.

O. Finish: Baked enamel or powder coat. 1. Color: As selected by Architect from manufacturer's full range.

2.5 FABRICATION

A. Fabricate metal lockers square, rigid, without warp, and with metal faces flat and free of dents or distortion. Make exposed metal edges safe to touch and free of sharp edges and burrs. 1. Form body panels, doors, shelves, and accessories from one-piece steel sheet unless

otherwise indicated. 2. Provide fasteners, filler plates, supports, clips, and closures as required for complete

installation.

B. Fabricate each metal locker with an individual door and frame; individual top, bottom, and back; and common intermediate uprights separating compartments. Factory weld frame members of each metal locker together to form a rigid, one-piece assembly.

C. Equipment: Provide each locker with an identification plate and the following equipment: 1. Single-Tier Units: Shelf, one double-prong ceiling hook, and two single-prong wall hooks. 2. Double-Tier Units: One double-prong ceiling hook and two single-prong wall hooks. 3. Triple-Tier Units: One double-prong ceiling hook. 4. Coat Rods: For each compartment of each locker.

Page 8: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School - Title IX and Upgrades Beaverton School District No. 48 BLRB Project No.: 14.84P

Permit Set May 15, 2015

BLRB Architects - Portland, Oregon METAL LOCKERS 10 51 13 - 6

D. Knocked-Down Construction: Fabricate metal lockers using nuts, bolts, screws, or rivets for nominal assembly at Project site.

E. Welded Construction: Factory preassemble metal lockers by welding all joints, seams, and connections; with no bolts, nuts, screws, or rivets used in assembly of main locker groups. Factory weld main locker groups into one-piece structures. Grind exposed welds flush.

F. Accessible Lockers: Fabricate as follows: 1. Locate bottom shelf no lower than 15 inches above the floor. 2. Where hooks, coat rods, or additional shelves are provided, locate no higher than 48 inches

above the floor.

G. Continuous Base: Formed into channel or zee profile for stiffness, and fabricated in lengths as long as practical to enclose base and base ends of metal lockers; finished to match lockers.

H. Continuous Sloping Tops: Fabricated in lengths as long as practical, without visible fasteners at splice locations; finished to match lockers. 1. Sloping-top corner fillers, mitered.

I. Individual Sloping Tops: Fabricated in width to fit one locker frame in lieu of flat locker tops; with integral back; finished to match lockers. Provide wedge-shaped divider panels between lockers.

J. Recess Trim: Fabricated with minimum 2-1/2-inch face width and in lengths as long as practical; finished to match lockers.

K. Filler Panels: Fabricated in an unequal leg angle shape; finished to match lockers. Provide slip-joint filler angle formed to receive filler panel.

L. Boxed End Panels: Fabricated with 1-inch-wide edge dimension, and designed for concealing fasteners and holes at exposed ends of nonrecessed metal lockers; finished to match lockers. 1. Provide one-piece panels for double-row (back-to-back) locker ends.

M. Finished End Panels: Designed for concealing unused penetrations and fasteners, except for perimeter fasteners, at exposed ends of nonrecessed metal lockers; finished to match lockers. 1. Provide one-piece panels for double-row (back-to-back) locker ends.

N. Center Dividers: Full-depth, vertical partitions between bottom and shelf; finished to match lockers.

2.6 ACCESSORIES

A. Fasteners: Zinc- or nickel-plated steel, slotless-type, exposed bolt heads; with self-locking nuts or lock washers for nuts on moving parts.

B. Anchors: Material, type, and size required for secure anchorage to each substrate. 1. Provide nonferrous-metal or hot-dip galvanized anchors and inserts on inside face of exterior

walls for corrosion resistance. 2. Provide toothed-steel or lead expansion sleeves for drilled-in-place anchors.

Page 9: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School - Title IX and Upgrades Beaverton School District No. 48 BLRB Project No.: 14.84P

Permit Set May 15, 2015

BLRB Architects - Portland, Oregon METAL LOCKERS 10 51 13 - 7

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine walls, floors, and support bases, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of the Work.

B. Prepare written report, endorsed by Installer, listing conditions detrimental to performance of the Work.

C. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 INSTALLATION

A. General: Install lockers level, plumb, and true; shim as required, using concealed shims. 1. Anchor locker runs at ends and at intervals recommended by manufacturer, but not more than

36 inches o.c. Using concealed fasteners, install anchors through backup reinforcing plates, channels, or blocking as required to prevent metal distortion.

2. Anchor single rows of metal lockers to walls near top of lockers and to floor. 3. Anchor back-to-back metal lockers to floor.

B. Knocked-Down Lockers: Assemble with standard fasteners, with no exposed fasteners on door faces or face frames.

C. Welded Lockers: Connect groups together with standard fasteners, with no exposed fasteners on face frames.

D. Equipment: 1. Attach hooks with at least two fasteners. 2. Attach door locks on doors using security-type fasteners. 3. Identification Plates: Identify metal lockers with identification indicated on Drawings.

a. Attach plates to each locker door, near top, centered, with at least two aluminum rivets. b. Attach plates to upper shelf of each open-front metal locker, centered, with a least two

aluminum rivets.

E. Trim: Fit exposed connections of trim, fillers, and closures accurately together to form tight, hairline joints, with concealed fasteners and splice plates. 1. Attach recess trim to recessed metal lockers with concealed clips. 2. Attach filler panels with concealed fasteners. Locate filler panels where indicated on Drawings. 3. Attach sloping-top units to metal lockers, with closures at exposed ends. 4. Attach boxed end panels using concealed fasteners to conceal exposed ends of nonrecessed

metal lockers. 5. Attach finished end panels using fasteners only at perimeter to conceal exposed ends of

nonrecessed metal lockers.

F. Fixed Locker Benches: Provide no fewer than two pedestals for each bench, uniformly spaced not more than 72 inches apart. Securely fasten tops of pedestals to undersides of bench tops, and anchor bases to floor.

G. Freestanding Locker Benches: Place benches in locations indicated on Drawings.

Page 10: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School - Title IX and Upgrades Beaverton School District No. 48 BLRB Project No.: 14.84P

Permit Set May 15, 2015

BLRB Architects - Portland, Oregon METAL LOCKERS 10 51 13 - 8

3.3 ADJUSTING

A. Clean, lubricate, and adjust hardware. Adjust doors and latches to operate easily without binding.

3.4 PROTECTION

A. Protect metal lockers from damage, abuse, dust, dirt, stain, or paint. Do not permit use during construction.

B. Touch up marred finishes, or replace metal lockers that cannot be restored to factory-finished appearance. Use only materials and procedures recommended or furnished by locker manufacturer.

END OF SECTION 10 51 13

Page 11: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

www.northwest-school-eq.com

Sunset HS List lockers Submittal package with dimensional notes.

Type A and C lockers are All-Welded. These will come in pre-welded cabinets. Refer to cut sheet showing grouping (A1, A2, and A3). The maximum width on an 18” wide door is 3 locker frames wide (53-15/16”). Lockers need to have a maximum of ½” overhang, we normally see the bases about a ½” short on width and length to allow for some kind of overhang – this is an architectural preference.

- On this particular project all exposed ends receive a 1” boxed end panel,

this needs to be added at ALL exposed ends. The attached drawings have this calculated into the dimensions.

- We have filler panels that we typically use on all projects, they are 6” wide

and are cut down in the field as needed. A 6” wide filler can be cut down to as little as 2”. The attached dimensions show exactly what the lockers would take to fit, I suggest adding 4” which will allow the use of a filler if the space in the room can accommodate.

Type B and D lockers are KD (Knock Down) and assembled in the field. I did not put the dimensions on the attached drawings for these areas. These are much more simple – Add 1/32” growth per locker frame and 1” @ each exposed end. Same rules would apply for the fillers.

25 82nd

Drive, Ste. 200 Gladstone OR 97207

Page 12: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in
mharmel
Callout
ENSURE THAT 1" END PANELS DO NOT MAKE LOCKERS PROTRUDE PAST THE WALL.
mharmel
Line
Page 13: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in
mharmel
Callout
SITTING ON A 6" ELEVATED CONCRETE BASE AT DIFFERENT ELEVATION FROM A2 AND A3.
Page 14: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in
mharmel
Rectangle
mharmel
Callout
4" BASE. SEE A5.11C
mharmel
Rectangle
Page 15: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in
Page 16: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in
mharmel
Callout
4" BASE. SEE A5.11C
mharmel
Rectangle
mharmel
Rectangle
Page 17: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in
mharmel
Polygon
Page 18: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

04/13/10

SUPERIOR

Heavy-Duty Ventilated (HDV)

KD Wardrobe and Box Lockers

General: Lockers shall be "Superior Heavy-Duty Ventilated (HDV) KD Wardrobe and Box Lockers" as

manufactured by List Industries Inc. or approved equal. Fabricate lockers square, rigid and without

warp, with metal faces flat and free from dents or distortion. Make all exposed metal edges safe to

touch. Weld frame members together to form rigid, one-piece structure. Weld, bolt, or rivet other

joints and connections as standard with manufacturer. Grind exposed welds flush. Do not expose

bolts or rivet heads on fronts of locker doors or frames except for fastening of number plates and

recessed handle.

Lockers shall be GREENGUARD Children & Schools Certified

SM

Finishing: All locker parts to be cleaned and coated after fabrication with a seven stage zinc/iron

phosphate solution to inhibit corrosion, followed by a coat of high grade custom blend powder

electrostatically sprayed and baked at 350 degrees Fahrenheit for a minimum of 20 minutes to provide

a tough durable finish. Color to be selected from manufacturer's standard list of colors. Interior

components are to be painted choice of #729 Parchment or #725 Hallowell Gray. Two-Tone Color

Combination: Shall be at no additional cost with the locker frame and trim chosen from one color

and the doors may be one of any other color chosen from manufacturers standard selection.

Frame: Fabricate of 16 gauge (minimum) channels, with integral continuous door stop/strike formed

on both latch and hinge side vertical members. Cross frame members of 16 gauge channel shapes,

including intermediate cross frame members on double and triple tier (frames with doors over 18"

high) lockers shall be securely welded to the vertical framing members to ensure rigidity. Rubber

bumpers shall be provided to cushion door closing.

HDV Wardrobe Doors: Doors 20” high and higher shall be fabricated from single sheet prime 14

gauge with single bends at top and bottom and double bends at the sides. The channel formed by the

double bend at the latch side is designed to fully conceal the lock bar. Doors are to be perforated with

5/8” x 1-1/2” diamonds.

HDV Box Doors: Doors 18" high and under to be fabricated from single sheet prime 14 gauge with

single bends at top, bottom and sides. Doors shall include a combination friction catch door pull.

Padlock Strike Plates are optional. Doors shall be fabricated to accept a built-in combination lock or

padlock. Doors with projecting spring latches shall not be acceptable. Doors are to be perforated

with 7/16” x 15/16” diamonds.

Stainless Steel Recessed Locker Handle: All wardrobe doors shall have recessed not less than 304

stainless steel handle shaped to receive a padlock or built-in combination lock. The recess pan shall be

deep enough to have the lock be flush with the outer door face. Box doors shall be equipped with a

combination friction catch door pull as stated above.

Page 19: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

04/13/10

SUPERIOR

Heavy-Duty Ventilated (HDV) KD Wardrobe and Box Lockers (Page 2)

Latch Assembly: The latching mechanism for wardrobe doors shall be finger lift control type

constructed of 14 gauge (minimum) steel with a nylon cover that has a generous finger pull. Spring

activated nylon slide latches shall be completely enclosed in the lock channel allowing doors to close

with the lock in the locked position. Lock bar shall be hot dip galvanized and install after paint to

ensure proper paint coverage and lock bar operation. Locking devise shall be designed for use with

either built-in combination locks or padlocks. Latch hooks shall be securely welded to the vertical

frame channel on the strike side to engage the nylon slide latches. Three latch hooks for doors 48"

and higher, two latch hooks for doors under 48" high.

Door Hinges: All doors shall include a 16 gauge continuous piano hinge welded to the door and riveted

to the frame. All doors to be right hand, side hinged.

Body: Fabricate backs of 18 gauge (minimum) solid sheet, sides of 16 gauge (minimum) sheet steel

with double flanged connections extending full height. Sides to be diamond perforated for added

ventilation. Form top, bottom and intermediate tier dividers of 16 gauge (minimum) solid sheet steel

with single return bends at all sides. Bolt top and bottom as well as horizontal tier dividers of

wardrobe openings to front horizontal frame members at not less than one place in addition to side

panels. Form hat shelves at 60” and 72” high single tier lockers of 16 gauge (minimum) sheet steel

with single bends at sides and back and a double bend at front.

Locks (If required): Shall be master-keyed to one system for the entire project. (See lock use chart for

suggested lock application)

Equipment: Furnish each locker with the following items, unless otherwise shown.

Single tier lockers: Openings 60” and 72” shall include one hat shelf, one double prong ceiling

hook and a minimum of two single prong hooks.

Double tier lockers: Openings 30” and 36” high shall include one double prong ceiling hook

and a minimum of two single prong hooks.

Triple tier lockers: Openings 20” and 24” high shall include one double prong ceiling hook

only.

Box lockers: No hooks

Two-Year Warranty: Superior KD lockers are covered against all defects in materials and

workmanship excluding finish, damage resulting from deliberate destruction and vandalism under this

section for a period of two years.

Page 20: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

06/13/11

SUPERIOR

Fully-Framed All-Welded

P.E. and Team Lockers

General: Lockers shall be "Superior Fully-Framed All-Welded Team & P.E. Athletic Lockers" as

manufactured by List Industries Inc. or approved equal. All lockers shall be factory-assembled, of all

MIG welded construction, in multiple column units to meet job conditions. Assembly of locker bodies

by means of bolts, screws, or rivets will not be permitted. Welding of knockdown locker

construction is not acceptable. Grind exposed welds and metal edges flush and make safe to touch.

Lockers shall be GREENGUARD Children & Schools Certified

SM

Finishing: All locker parts to be cleaned and coated after fabrication with a seven stage zinc/iron

phosphate solution to inhibit corrosion, followed by a coat of high grade custom blend powder

electrostatically sprayed and baked at 350 degrees Fahrenheit for a minimum of 20 minutes to provide

a tough durable finish. Color to be selected from manufacturer's standard list of colors. Two-Tone

Color Combination: Shall be at no additional cost with the locker body, frame and trim chosen from

one color and the doors may be one of any other color chosen from manufacturers standard

selection.

Frame / Vertical Side panels: Shall be of 13 gauge ½” flattened expanded metal framed by 16 gauge

Hollow "T" tubular sections and channel frame members designed to enclose all four edges of the side

panel with the entire assembly MIG welded to form a rigid frame for each locker. The channel frame

members are welded to the front and rear vertical frame members to create and anchor bearing

surface of 1-1/4 inches wide x the depth of the locker at each side panel.

Integral Frame Locker base: 14 gauge formed structural channels are MIG welded to the front and

rear vertical side panel frame members to allow placement of locker bottom a minimum 2-3/4" above

floor level. Locker bottom shelf located less than 2” above floor level will not be acceptable.

Team Wardrobe Doors: Doors 20" high and over and 15” wide and under are to be fabricated from

single sheet prime 14 gauge with single bends at top and bottom and double bends at the sides. The

channel formed by the double bend at the latch side is designed to fully conceal the lock bar. The

latching mechanism shall be finger lift control type constructed of 14 gauge (minimum) steel with a

nylon cover that has a generous finger pull. Lock bar shall be hot dip galvanized and installed after

paint to ensure proper paint coverage and lock bar operation. Spring activated nylon slide latches shall

be completely enclosed in the lock channel allowing doors to close with the lock in the locked position.

Locking devise shall be designed for use with either built-in combination locks or padlocks. Latch

hooks shall be 11 gauge (minimum) with riveted bumpers and shall be MIG welded to vertical frame

member. Provide three latch hooks for doors 48" and over and two for doors under 48". Doors to be

perforated with 5/8” x 1-1/2” diamonds.

mharmel
Text Box
SEE A5.11C LOCKER ELEVATIONS FOR BASE THICKNESSES
Page 21: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

06/13/11

SUPERIOR

Fully-Framed All-Welded P.E. and Team Lockers (Page 2)

P.E. Gym Doors 12” High And Under: Doors 12" high and under to be top hinged and be fabricated

from single sheet prime 14 gauge with single bend at top and sides with a double bend at latch point

(bottom). A spring loaded galvanized latch assembly shall be securely welded to the inside of the

door. The latch shall be a minimum of 11 gauge, be equipped with a stainless steel spring and shall

automatically engage when door is closed. Rubber bumpers shall be riveted to return bends on doors.

Locking devise shall be designed for use with both a padlock and built-in lock. Padlock Strike Plates are

optional. Doors to be perforated with 7/16” x 15/16” diamonds.

P.E. Gym Doors 15” And 18” High: Doors 15” and 18" high to be side hinged and be fabricated from

single sheet prime 14 gauge with single bend at top and bottom and double bends at hinge and latch

sides. A spring loaded galvanized latch assembly shall be securely welded to the inside of the door.

The latch shall be a minimum of 11 gauge, be equipped with a stainless steel spring and shall

automatically engage an 11 gauge full height continuous door strike when the door is closed. The

door strike is to be MIG welded to the frame. Rubber bumpers shall be riveted to return bends on

doors. Locking devise shall be designed for use with both a padlock and built-in lock. Padlock Strike

Plates are optional. Doors to be perforated with 7/16” x 15/16” diamonds.

Seamless Drawn Locker Handle: All wardrobe doors 20” high and over shall have a seamless drawn

not less than 304 stainless steel recessed handle shaped to receive a padlock or built-in combination

lock. The recessed handle shall be deep enough to have the lock be completely flush with the outer

door face.

Door Hinges: Hinges for wardrobe and side hinged gym doors shall not be less than 3-1/2" long 13

gauge seven knuckle pin type, securely riveted to frame and welded to the door. Doors are to be

secured to frame with a minimum of two tamper resistant rivets per hinge. Provide 3 hinges for doors

48" and higher and 2 for doors shorter than 48". All doors shall be right hand side hinged except top

hinged gym doors as noted above. Top hinged gym doors shall be hinged using a 3/16" diameter

continuous hinge rod completely recessed into the door with a concealed fastener.

Flat Tops: Shall be formed of one piece of 16 gauge cold rolled sheet steel and shall be an integral

part MIG welded to each vertical side panel frame member and be continuous to cover the full width

of a multiple framed locker unit.

Hat Shelves, Intermediate Shelves and Bottoms: Shall be 16 gauge galvanneal sheet steel, have

double bends at front and shall engage slots in the Hollow "T" vertical frame members at all four

corners and be securely welded to the frame and side. Locker bottom shelf located less than 2” above

floor level will not be acceptable.

Backs: Shall be 18 gauge cold rolled sheet steel, be continuous to cover a multiple framed unit and be

welded to each vertical side panel frame member.

mharmel
Text Box
SIDE HINGES
mharmel
Line
mharmel
Line
mharmel
Callout
SIDE HINGES
Page 22: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

06/13/11

SUPERIOR

Fully-Framed All-Welded P.E. and Team Lockers (Page 3)

Locks (If required): Shall be master keyed to one system for the entire project. (See lock use chart for

suggested lock application).

Equipment: Furnish each locker with the following items, unless otherwise shown.

Single tier lockers: Openings 60” and 72” shall include one galvanneal hat shelf, one double

prong ceiling hook and a minimum of two single prong hooks.

Double and triple tier lockers: Openings 20” thru 36” high shall include one double prong

ceiling hook and a minimum of two single prong hooks.

Box lockers: No hooks

Lifetime Warranty: Superior Fully-Framed All-Welded Lockers are covered against all defects in

materials and workmanship excluding finish, damage resulting from deliberate destruction and

vandalism under this section for the lifetime of the facility.

Page 23: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in
Page 24: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in
Page 25: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in
rtobin
Line
rtobin
Line
Page 26: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in
rtobin
Line
rtobin
Line
rtobin
Line
rtobin
Line
mharmel
Polygon
mharmel
Polygonal Line
mharmel
Callout
90 DEGREE FILLER PANEL IN MULTIPLE PLACES ON DRAWINGS
Page 27: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Submittal Review

TO: Pavilion Construction DATE: 07.01.2015 JOB NO.: 1484P 4700 SW Macadam Ave Suite 200 ATTENTION: Riley Tobin Portland, OR 97239 RE: BSD Sunset High School

Concession Stand/Interior Renovations Package 1

Submittal: 105113 Metal Lockers Informational Submittal

Approved Approved As Noted Revise as Noted/Resubmit Rejected/Resubmit As Specified No Action Required Submittal Not Requested/Returned Without Review

Approval is for conformance with information given and the design concept expressed in the Contract Documents. Contractor is responsible for quantities and dimensions to be confirmed and correlated; for fabrication process; for means methods, techniques, sequences and procedures of construction; for coordination of the Work; and for all safety aspects of performing the Work. Approval does not modify the Contract Documents and approval of a specific item does not indicate approval of an assembly of which the item is a component.

Specification Section Title Notation

105113 1.4A Product Data Reviewed in Separate Submittal

105113 1.4B Shop Drawings Reviewed in Separate Submittal

105113 1.4C Samples For Each Color Selected Reviewed in Separate Submittal

105113 1.4D Samples For Initial Selection Reviewed in Separate Submittal

105113 1.4E Samples For Verification Reviewed in Separate Submittal

105113 1.4 F Product Schedule Reviewed in Separate Submittal

105113 1.5A Qualification Data Approved

105113 1.5B Sample Warranty Approved

1001 SW 5th Ave. // Suite 1100 // Portland // OR 97204-1127 // P: 503.535.0707 // www.blrb.com

Page 28: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School 13840 NW Cornell Rd.

Portland, OR 97229

Pavilion Construction NW, LLC 4700 SW Macadam Ave. Portland, OR 97239 Phone: (503)290-5005 Fax: (503)244-1810 www.pavilionconstruction.com Page 1 of 1

To: BLRB ARCHITECTS, P.S. Date: 06/30/2015

Attn: RICHARD HIGGINS

1001 SW 5TH AVE., SUITE 1100 Contact Phone: 503-535-0707

PORTLAND, OR 97204 Contact Email: [email protected]

CC’d:

SUBMITTAL TRANSMITTAL FOR APPROVAL

Submittal #: 42.1 Rev.#: 0 In Accordance with Specification Section #: 105113

This is a submittal for Metal Lockers items per the table below as reviewed and noted by Pavilion Construction NW, LLC, and provided by . Please provide a response to this submittal by 07/02/2015.

Pavilion Status: Sent/Submitted

Notes:

Submitted By: Riley Tobin Phone: (503)290-5005

Email Address: [email protected] Fax: (503)244-1810

SUBMITTAL RESPONSE

Architect’s Response Schedule Tracking Proceed Date Received from Sub/Sup 06/30/2015

Proceed, as noted Date Requested to be returned 07/02/2015

Revise and Resubmit Date Returned from Architect

Material Return without Review Date Returned to Sup/Sup

Comments:

rtobin
Pavilion Review
rtobin
Accepted
rtobin
Text Box
06/30/15
rtobin
Text Box
Riley Tobin
mharmel
New Stamp
mharmel
Line
mharmel
Line
mharmel
Text Box
Mike Harmel
mharmel
Text Box
07.01.2015
Page 29: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School - Title IX and Upgrades Beaverton School District No. 48 BLRB Project No.: 14.84P

Permit Set May 15, 2015

BLRB Architects - Portland, Oregon METAL LOCKERS 10 51 13 - 1

SECTION 10 51 13 - METAL LOCKERS

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

1.2 SUMMARY

A. Section Includes: 1. Knocked-down athletic lockers. 2. Welded athletic lockers.

1.3 PREINSTALLATION MEETINGS

A. Preinstallation Conference: Conduct conference at Project site.

1.4 ACTION SUBMITTALS

A. Product Data: For each type of metal locker. 1. Include construction details, material descriptions, dimensions of individual components and

profiles, and finishes for each type of metal locker.

B. Shop Drawings: For metal lockers. 1. Include plans, elevations, sections, details, and attachments to other work. 2. Show locker trim and accessories. 3. Include locker identification system and numbering sequence.

C. Samples: For each color specified, in manufacturer's standard size.

D. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

E. Samples for Verification: For the following products, in manufacturer's standard size: 1. Lockers and equipment. 2. Locker benches.

F. Product Schedule: For lockers.

1.5 INFORMATIONAL SUBMITTALS

A. Qualification Data: For Installer.

B. Sample Warranty: For special warranty.

rtobin
Text Box
See Pages 10-14
rtobin
Text Box
See Pages 15-16
Page 30: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School - Title IX and Upgrades Beaverton School District No. 48 BLRB Project No.: 14.84P

Permit Set May 15, 2015

BLRB Architects - Portland, Oregon METAL LOCKERS 10 51 13 - 2

1.6 CLOSEOUT SUBMITTALS

A. Maintenance Data: For adjusting, repairing, and replacing locker doors and latching mechanisms to include in maintenance manuals.

1.7 MAINTENANCE MATERIAL SUBMITTALS

A. Furnish extra materials that match products installed and that are packaged with protective covering for storage and identified with labels describing contents. 1. Full-size units of the following metal locker hardware items equal to 10 percent of amount

installed for each type and finish installed, but no fewer than five units: 2. Locks.

a. Identification plates. b. Hooks.

1.8 DELIVERY, STORAGE, AND HANDLING

A. Do not deliver metal lockers until spaces to receive them are clean, dry, and ready for their installation.

1.9 FIELD CONDITIONS

A. Field Measurements: Verify actual dimensions of recessed openings by field measurements before fabrication.

1.10 COORDINATION

A. Coordinate sizes and locations of concrete bases for metal lockers.

B. Coordinate sizes and locations of framing, blocking, furring, reinforcements, and other related units of work specified in other Sections to ensure that metal lockers can be supported and installed as indicated.

1.11 WARRANTY

A. Special Warranty: Manufacturer agrees to repair or replace components of metal lockers that fail in materials or workmanship, excluding finish, within specified warranty period. 1. Failures include, but are not limited to, the following:

a. Structural failures. b. Faulty operation of latches and other door hardware.

2. Damage from deliberate destruction and vandalism is excluded. 3. Warranty Period for Knocked-Down Metal Lockers: Two years from date of Substantial

Completion. 4. Warranty Period for Welded Metal Lockers: Lifetime from date of Substantial Completion.

Page 31: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School - Title IX and Upgrades Beaverton School District No. 48 BLRB Project No.: 14.84P

Permit Set May 15, 2015

BLRB Architects - Portland, Oregon METAL LOCKERS 10 51 13 - 3

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. Source Limitations: Obtain metal lockers and accessories from single source from single locker manufacturer. 1. Obtain locks from single lock manufacturer.

2.2 PERFORMANCE REQUIREMENTS

A. Accessibility Requirements: For lockers indicated to be accessible, comply with applicable provisions in the U.S. Architectural & Transportation Barriers Compliance Board's ADA-ABA Accessibility Guidelines and ICC A117.1.

2.3 KNOCKED-DOWN ATHLETIC LOCKERS

A. Basis-of-Design Product: Subject to compliance with requirements, provide Republic Storage Systems, LLC; Heavy Duty Ventilated or a comparable product by one of the following: 1. Art Metal Products. 2. Lyon Workspace Products, LLC. 3. Penco Products, Inc.

B. Perforated Doors: One piece; fabricated from 0.075-inch nominal-thickness steel sheet with manufacturer's standard diamond perforations; formed into channel shape with double bend at vertical edges and with right-angle single bend at horizontal edges and latch point (bottom) and right-angle single bend at remaining edges for box lockers. 1. Reinforcement: Manufacturer's standard reinforcing angles, channels, or stiffeners for doors

more than 15 inches wide; welded to inner face of doors.

C. Body: Assembled by riveting or bolting body components together. Fabricate from unperforated steel sheet with thicknesses as follows: 1. Tops and Bottoms: 0.060-inch nominal thickness, with single bend at edges. 2. Backs: 0.048-inch nominal thickness. 3. Shelves: 0.060-inch nominal thickness, with double bend at front and single bend at sides and

back.

D. Unperforated Sides: Fabricated from 0.060-inch nominal-thickness steel sheet.

E. Frames: Channel formed; fabricated from 0.060-inch nominal-thickness steel sheet or 0.097-inch nominal-thickness steel angles; lapped and factory welded at corners; with top and bottom main frames factory welded into vertical main frames. Form continuous, integral, full-height door strikes on vertical main frames. 1. Cross Frames for Double-Tier and Triple-Tier Lockers: Channel formed and fabricated from

same material as main frames; welded to vertical main frames.

F. Hinges: Welded to door and attached to door frame with no fewer than two factory-installed rivets per hinge that are completely concealed and tamper resistant when door is closed; fabricated to swing 180 degrees. 1. Knuckle Hinges: Steel, full loop, five or seven knuckles, tight pin; minimum 2 inches high.

Provide no fewer than three hinges for each door more than 42 inches high.

Page 32: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School - Title IX and Upgrades Beaverton School District No. 48 BLRB Project No.: 14.84P

Permit Set May 15, 2015

BLRB Architects - Portland, Oregon METAL LOCKERS 10 51 13 - 4

G. Door Handle and Latch: Stainless-steel strike plate with integral pull; with steel padlock loop that projects through metal locker door.

H. Identification Plates: Manufacturer's standard, etched, embossed, or stamped aluminum plates, with numbers and letters at least 3/8 inch high.

I. Hooks: Manufacturer's standard ball-pointed type, aluminum or steel; zinc plated.

J. Coat Rods: Manufacturer's standard.

K. Continuous Sloping Tops: Fabricated from 0.048-inch nominal-thickness steel sheet, with a pitch of approximately 20 degrees. 1. Closures: Vertical-end type.

L. Filler Panels: Fabricated from 0.048-inch nominal-thickness steel sheet.

M. Boxed End Panels: Fabricated from 0.060-inch nominal-thickness steel sheet.

N. Materials: 1. Cold-Rolled Steel Sheet: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B, suitable for

exposed applications.

O. Finish: Baked enamel or powder coat. 1. Color: As selected by Architect from manufacturer's full range.

2.4 WELDED ATHLETIC LOCKERS

A. Basis-of-Design Product: Subject to compliance with requirements, provide Republic Storage Systems, LLC; All-Welded Ventilated or a comparable product by one of the following: 1. Art Metal Products. 2. Lyon Workspace Products, LLC. 3. Penco Products, Inc.

B. Perforated Doors: One piece; fabricated from 0.075-inch nominal-thickness steel sheet with manufacturer's standard diamond perforations; formed into channel shape with double bend at vertical edges and with right-angle single bend at horizontal edges and latch point (bottom) and right-angle single bend at remaining edges for box lockers. 1. Reinforcement: Manufacturer's standard reinforcing angles, channels, or stiffeners for doors

more than 15 inches wide; welded to inner face of doors.

C. Body: Assembled by welding body components together. Fabricate from unperforated steel sheet with thicknesses as follows: 1. Tops and Bottoms: 0.060-inch nominal thickness, with single bend at edges. 2. Backs: 0.048-inch nominal thickness. 3. Shelves: 0.060-inch nominal thickness, with double bend at front and single bend at sides and

back.

D. Unperforated Sides: Fabricated from 0.060-inch nominal-thickness steel sheet.

E. Frames: Channel formed; fabricated from 0.060-inch nominal-thickness steel sheet or 0.097-inch nominal-thickness steel angles; lapped and factory welded at corners; with top and bottom main frames factory welded into vertical main frames. Form continuous, integral, full-height door strikes on vertical main frames.

Page 33: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School - Title IX and Upgrades Beaverton School District No. 48 BLRB Project No.: 14.84P

Permit Set May 15, 2015

BLRB Architects - Portland, Oregon METAL LOCKERS 10 51 13 - 5

1. Cross Frames for Double-Tier and Triple-Tier Lockers: Channel formed and fabricated from same material as main frames; welded to vertical main frames.

F. Hinges: Welded to door and attached to door frame with no fewer than two factory-installed rivets per hinge that are completely concealed and tamper resistant when door is closed; fabricated to swing 180 degrees. 1. Knuckle Hinges: Steel, full loop, five or seven knuckles, tight pin; minimum 2 inches high.

Provide no fewer than three hinges for each door more than 42 inches high.

G. Door Handle and Latch: Stainless-steel strike plate with integral pull; with steel padlock loop that projects through metal locker door.

H. Identification Plates: Manufacturer's standard, etched, embossed, or stamped aluminum plates, with numbers and letters at least 3/8 inch high.

I. Hooks: Manufacturer's standard ball-pointed type, aluminum or steel; zinc plated.

J. Coat Rods: Manufacturer's standard.

K. Continuous Sloping Tops: Fabricated from 0.048-inch nominal-thickness steel sheet, with a pitch of approximately 20 degrees. 1. Closures: Vertical-end type.

L. Filler Panels: Fabricated from 0.048-inch nominal-thickness steel sheet.

M. Boxed End Panels: Fabricated from 0.060-inch nominal-thickness steel sheet.

N. Materials: 1. Cold-Rolled Steel Sheet: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B, suitable for

exposed applications.

O. Finish: Baked enamel or powder coat. 1. Color: As selected by Architect from manufacturer's full range.

2.5 FABRICATION

A. Fabricate metal lockers square, rigid, without warp, and with metal faces flat and free of dents or distortion. Make exposed metal edges safe to touch and free of sharp edges and burrs. 1. Form body panels, doors, shelves, and accessories from one-piece steel sheet unless

otherwise indicated. 2. Provide fasteners, filler plates, supports, clips, and closures as required for complete

installation.

B. Fabricate each metal locker with an individual door and frame; individual top, bottom, and back; and common intermediate uprights separating compartments. Factory weld frame members of each metal locker together to form a rigid, one-piece assembly.

C. Equipment: Provide each locker with an identification plate and the following equipment: 1. Single-Tier Units: Shelf, one double-prong ceiling hook, and two single-prong wall hooks. 2. Double-Tier Units: One double-prong ceiling hook and two single-prong wall hooks. 3. Triple-Tier Units: One double-prong ceiling hook. 4. Coat Rods: For each compartment of each locker.

Page 34: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School - Title IX and Upgrades Beaverton School District No. 48 BLRB Project No.: 14.84P

Permit Set May 15, 2015

BLRB Architects - Portland, Oregon METAL LOCKERS 10 51 13 - 6

D. Knocked-Down Construction: Fabricate metal lockers using nuts, bolts, screws, or rivets for nominal assembly at Project site.

E. Welded Construction: Factory preassemble metal lockers by welding all joints, seams, and connections; with no bolts, nuts, screws, or rivets used in assembly of main locker groups. Factory weld main locker groups into one-piece structures. Grind exposed welds flush.

F. Accessible Lockers: Fabricate as follows: 1. Locate bottom shelf no lower than 15 inches above the floor. 2. Where hooks, coat rods, or additional shelves are provided, locate no higher than 48 inches

above the floor.

G. Continuous Base: Formed into channel or zee profile for stiffness, and fabricated in lengths as long as practical to enclose base and base ends of metal lockers; finished to match lockers.

H. Continuous Sloping Tops: Fabricated in lengths as long as practical, without visible fasteners at splice locations; finished to match lockers. 1. Sloping-top corner fillers, mitered.

I. Individual Sloping Tops: Fabricated in width to fit one locker frame in lieu of flat locker tops; with integral back; finished to match lockers. Provide wedge-shaped divider panels between lockers.

J. Recess Trim: Fabricated with minimum 2-1/2-inch face width and in lengths as long as practical; finished to match lockers.

K. Filler Panels: Fabricated in an unequal leg angle shape; finished to match lockers. Provide slip-joint filler angle formed to receive filler panel.

L. Boxed End Panels: Fabricated with 1-inch-wide edge dimension, and designed for concealing fasteners and holes at exposed ends of nonrecessed metal lockers; finished to match lockers. 1. Provide one-piece panels for double-row (back-to-back) locker ends.

M. Finished End Panels: Designed for concealing unused penetrations and fasteners, except for perimeter fasteners, at exposed ends of nonrecessed metal lockers; finished to match lockers. 1. Provide one-piece panels for double-row (back-to-back) locker ends.

N. Center Dividers: Full-depth, vertical partitions between bottom and shelf; finished to match lockers.

2.6 ACCESSORIES

A. Fasteners: Zinc- or nickel-plated steel, slotless-type, exposed bolt heads; with self-locking nuts or lock washers for nuts on moving parts.

B. Anchors: Material, type, and size required for secure anchorage to each substrate. 1. Provide nonferrous-metal or hot-dip galvanized anchors and inserts on inside face of exterior

walls for corrosion resistance. 2. Provide toothed-steel or lead expansion sleeves for drilled-in-place anchors.

Page 35: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School - Title IX and Upgrades Beaverton School District No. 48 BLRB Project No.: 14.84P

Permit Set May 15, 2015

BLRB Architects - Portland, Oregon METAL LOCKERS 10 51 13 - 7

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine walls, floors, and support bases, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of the Work.

B. Prepare written report, endorsed by Installer, listing conditions detrimental to performance of the Work.

C. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 INSTALLATION

A. General: Install lockers level, plumb, and true; shim as required, using concealed shims. 1. Anchor locker runs at ends and at intervals recommended by manufacturer, but not more than

36 inches o.c. Using concealed fasteners, install anchors through backup reinforcing plates, channels, or blocking as required to prevent metal distortion.

2. Anchor single rows of metal lockers to walls near top of lockers and to floor. 3. Anchor back-to-back metal lockers to floor.

B. Knocked-Down Lockers: Assemble with standard fasteners, with no exposed fasteners on door faces or face frames.

C. Welded Lockers: Connect groups together with standard fasteners, with no exposed fasteners on face frames.

D. Equipment: 1. Attach hooks with at least two fasteners. 2. Attach door locks on doors using security-type fasteners. 3. Identification Plates: Identify metal lockers with identification indicated on Drawings.

a. Attach plates to each locker door, near top, centered, with at least two aluminum rivets. b. Attach plates to upper shelf of each open-front metal locker, centered, with a least two

aluminum rivets.

E. Trim: Fit exposed connections of trim, fillers, and closures accurately together to form tight, hairline joints, with concealed fasteners and splice plates. 1. Attach recess trim to recessed metal lockers with concealed clips. 2. Attach filler panels with concealed fasteners. Locate filler panels where indicated on Drawings. 3. Attach sloping-top units to metal lockers, with closures at exposed ends. 4. Attach boxed end panels using concealed fasteners to conceal exposed ends of nonrecessed

metal lockers. 5. Attach finished end panels using fasteners only at perimeter to conceal exposed ends of

nonrecessed metal lockers.

F. Fixed Locker Benches: Provide no fewer than two pedestals for each bench, uniformly spaced not more than 72 inches apart. Securely fasten tops of pedestals to undersides of bench tops, and anchor bases to floor.

G. Freestanding Locker Benches: Place benches in locations indicated on Drawings.

Page 36: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

Sunset High School - Title IX and Upgrades Beaverton School District No. 48 BLRB Project No.: 14.84P

Permit Set May 15, 2015

BLRB Architects - Portland, Oregon METAL LOCKERS 10 51 13 - 8

3.3 ADJUSTING

A. Clean, lubricate, and adjust hardware. Adjust doors and latches to operate easily without binding.

3.4 PROTECTION

A. Protect metal lockers from damage, abuse, dust, dirt, stain, or paint. Do not permit use during construction.

B. Touch up marred finishes, or replace metal lockers that cannot be restored to factory-finished appearance. Use only materials and procedures recommended or furnished by locker manufacturer.

END OF SECTION 10 51 13

Page 37: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in
Page 38: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in
Page 39: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in
Page 40: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in
Page 41: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in
Page 42: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

401 Jim Moran Blvd, P.O. Box 9601, Deerfield Beach, FL 33442 tel 954-429-9155 fax 954-428-3843

www.ListIndustries.com

SUPERIOR FULLY-FRAMED ALL WELDED LOCKERS LIFETIME WARRANTY

To: Sample Project: Sample LIST INDUSTRIES, INC. JOB: Sample Substantial Completion Date: Sample

Superior Fully-Framed Lockers carry a lifetime warranty against defect in materials and workmanship. Rust resulting from excessive use of cleaning agents, exposed to water from open doors and windows or roof leaks, improper ventilation causing high humidity, and chlorine saturated bathing suits will not be covered by this warranty. The warranty only applies to components manufactured by List Industries Inc. and excludes those items such as locks, wood bench-tops, cast iron pedestals, etc. Damage resulting from deliberate destruction, vandalism, shipping or faulty installation is not covered by this warranty. Any repairs, adjustments or replacements to be made under this warranty shall be performed only upon authorization in writing by List Industries Inc.

Page 43: Submittal Review - Pavilion Construction · Submittal Not Requested/Returned Without Review Approval is for conformance with information given and the design concept expressed in

SUPERIOR STANDARD K.D. LOCKER

TWO YEAR WARRANTY

To: Sample

Project: Sample

LIST INDUSTRIES JOB: Sample

Substantial Completion Date: Sample

Superior K.D. Conventional Steel lockers carry a full two-year warranty against defects in

material and workmanship.

This warranty does not cover scratching or marring of finishes occurring under normal

usage, perfect color matches on reorders (due to possible pigment variations over the

years.), nor fastness of special colors which may require special pigments. It does not

include any lock nor other devices not manufactured by List Industries. Rusting resulting

from excessive use of abrasive cleaning agents, exposure to water from open doors and

windows or roof leaks, improper ventilation causing high humidity, and chlorine

saturated bathing suits will not be covered in this warranty. Any repairs, adjustments or

replacements to be made under this warranty shall be performed only upon authorization

in writing by List Industries.

Deliberate destruction, vandalism or damage resulting from faulty installation is not

covered by this warranty.

We reserve the right to inspect any defective material and reserve the right to replace or

ship back to our factory at List Industries’ expense. Determination of warranty claims

require on site inspection by an authorized List Industries representative

401 jim moran blvd, PO Box 9601, Deerfield Beach, fl 33442 Pn 954-429-9155 Fax 954-429-3018