COMMERCIAL State Commercial Storage Tanks are ideal for increasing storage capacity when used along with water heaters and domestic hot water heating boilers. Meets or Exceeds the thermal efficiency and/or standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1 Foam Insulation - Thick foam insulation reduces stand-by heat loss and saves energy. Glass-Lined Tank - Alkaline borosilicate composition is permanently fused to steel by firing at a temperature of 1600°F, and will provide years of corrosion protection and dependable use at water storage temperatures up to 180°F. Heavy-Gauge Steel Jacket - With baked enamel finish. Threaded Openings - All tanks furnished with threaded openings for thermometer, relief valve, 2˝ recirculation lines (2-1/2˝ openings are optional on 119 gallon and 175 gallon models), tankstat, and drain valve. Five-Year Warranty Anode Rod - To provide additional corrosion protection and extra years of service, all 80 and 120 gallon models are equipped with an anode rod. Model PVG 0200 OVSA125 has two anode rods. Installation - Sized to fit space restrictive installations, all 80 and 120 gallon models fit through 30˝ doorways. Model PVG 0200 OVSA125 fits through a 33˝ doorway. Suggested Specifications Storage tank shall be a State glass-lined storage tank. Tank shall be _______˝ x _______˝ and have a nominal capacity of _____ g allons. Tank(s) shall have threaded openings as shown on drawings. Interior of tank(s) shall be glass-lined with an alkaline borosilicate composition which has been fused to the steel by firing at a temperature of 1600˚F. Glass coating shall be continuous over the entire inner surface of the tank. Outer jacket shall have a bak ed enamel finish. Foam insulation to meet or exceed ASHRAE current efficiency requirements. Cathodic protection shall be provided. Tank shall have a working pressure of ____ psi. Meets or exceeds the thermal efficiency and/or standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1 Storage Tanks Standard Jacketed Storage Tanks For more information on State ® contact: State Water Heaters 500 Tennessee Waltz Parkway, Ashland City, TN 37015 800.365.0024 Toll-free USA www.statewaterheaters.com STMSS00307 August 2008R ©2008 State Industries, Inc.

Upload: doanh

Post on 28-Feb-2018

246 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Storage Tanks - Commercial Hot Water Heater · PDF fileCOMMERCIAL State Commercial Storage Tanks are ideal for increasing storage capacity when used along with water heaters and domestic

C O M M E R C I A L

State Commercial Storage Tanks are ideal for increasing storage capacitywhen used along with water heaters and domestic hot water heating boilers.

Meets or Exceeds the thermal efficiency and/or standbyloss requirements of the U.S. Department of Energy andcurrent edition of ASHRAE/IESNA 90.1

Foam Insulation - Thick foam insulation reduces stand-by heat loss andsaves energy.

Glass-Lined Tank - Alkaline borosilicate composition is permanently fusedto steel by firing at a temperature of 1600°F, and will provide years ofcorrosion protection and dependable use at water storage temperatures upto 180°F.

Heavy-Gauge Steel Jacket - With baked enamel finish.

Threaded Openings - All tanks furnished with threaded openings forthermometer, relief valve, 2˝ recirculation lines (2-1/2˝ openings are optionalon 119 gallon and 175 gallon models), tankstat, and drain valve.

Five-Year Warranty

Anode Rod - To provide additional corrosion protection and extra years ofservice, all 80 and 120 gallon models are equipped with an anode rod.Model PVG 0200 OVSA125 has two anode rods.

Installation - Sized to fit space restrictive installations, all 80 and 120gallon models fit through 30˝ doorways. Model PVG 0200 OVSA125 fitsthrough a 33˝ doorway.

Suggested SpecificationsStorage tank shall be a State glass-lined storage tank. Tank shall be _______˝ x _______˝ and have a nominal capacity of _____ gallons. Tank(s) shall have threadedopenings as shown on drawings. Interior of tank(s) shall be glass-lined with an alkaline borosilicate composition which has been fused to the steel by firing at atemperature of 1600˚F. Glass coating shall be continuous over the entire inner surface of the tank. Outer jacket shall have a baked enamel finish. Foam insulation tomeet or exceed ASHRAE current efficiency requirements. Cathodic protection shall be provided. Tank shall have a working pressure of ____ psi. Meets or exceedsthe thermal efficiency and/or standby loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1

Storage TanksStandard Jacketed Storage Tanks

For more information on State® contact:State Water Heaters500 Tennessee Waltz Parkway, Ashland City, TN 37015800.365.0024 Toll-free USAwww.statewaterheaters.com

STMSS00307 August 2008R ©2008 State Industries, Inc.

193579_STMSS00307.indd 1193579_STMSS00307.indd 1 8/18/08 11:40:14 AM8/18/08 11:40:14 AM

Page 2: Storage Tanks - Commercial Hot Water Heater · PDF fileCOMMERCIAL State Commercial Storage Tanks are ideal for increasing storage capacity when used along with water heaters and domestic

C O M M E R C I A L

5 erugiF4 erugiF3 erugiF

2 erugiF1 erugiF

A B

C

D

E

F

F

3⁄4˝NPT

1˝ NPT

HANDHOLECLEANOUT

3⁄4˝ NPTPLUG ANODE

CLEANOUT

T&P OPENING

F

3⁄4˝ NPTPLUG ANODE

CIRCULATINGFITTINGS

DRAIN &AQUASTAT 30°

15°15°

A B

C

D

E

F

F

F

3⁄4˝NPT

31⁄2˝

111⁄2˝

G

1˝ NPT

11⁄4˝ NPTPLUG ANODE

ASME PLATE(ON PVG 01200 OVTA)

T&P OPENING

F

1˝ NPT(PVG 01200 OVTA)

30° 45°

SPECIFICATIONSNominal Standard Approx. Refer Dimensions In Inches

Model Gallon ASME Working toCapacity Pressure Ship. Wt. Figure A B C D E F G

PVG 0080 0OVT - Jacketed Vertical Only 2 —

A B

C

D

E

F

F

F

3⁄4˝NPT

10˝

111⁄2˝G

1˝ NPT

11⁄4˝ NPTPLUG ANODE

T&P OPENING

F

1˝ NPT(PVG 01200 OVTA)

30° 45°

ASME PLATE(ON PVG 01200 OVTA)

A

C

D

E

F

F

ANODE

F

INSULATED JACKET

3⁄4˝

DATA PLATEUNDER COVER

B

E

F

F

FINSULATED JACKET

3⁄4˝

B

ASME PLATE

A

CD

3⁄4˝(REAR)

3⁄4˝(REAR)

3⁄4˝

Storage TanksStandard Jacketed Storage Tanks

For more information on State® contact:State Water Heaters500 Tennessee Waltz Parkway, Ashland City, TN 37015800.365.0024 Toll-free USAwww.statewaterheaters.com

STMSS00307 August 2008R ©2008 State Industries, Inc.

PVG 0080 0OVT - JacketedVertical Only

PVG 0120 0OVT - JacketedVertical Only

PVG 0080 0OVTA125

PVG 0120 0OVTA125

PVG 0200 0OVTA125

80 63-1/2 25-1/2 2361.74

119 62 29-1/2 3203.00

80 50-1/2 25-1/4 369-

120 63-1/4 28 411-

175 77 32 560-

Model # Gal Cap A Dim B Dim Weight

PVG 0120 0OVT - Jacketed Vertical OnlyPVG 0080 0OVTA125PVG 0120 0OVTA125PVG 0200 0OVSA125

62

501⁄2

631⁄2

631⁄477

291⁄2

251⁄4

251⁄2

41⁄8

103⁄4 423⁄4

441⁄2

54

35⁄8

553⁄4631⁄2

441⁄ 2

42

2832

16

1112

6 7⁄86

6 7⁄8

9 3⁄4 2 —

21⁄2 —

2

2

80

119

80120175 Yes

YesYes

No

No 150

150

150150150

236

320

369411560

1

3

245

193579_STMSS00307.indd 2193579_STMSS00307.indd 2 8/18/08 11:40:16 AM8/18/08 11:40:16 AM