Pacific University Pacific University CommonKnowledge CommonKnowledge College of Optometry Theses, Dissertations and Capstone Projects 1967 Stereo-refraction: Its effect on far-point cylinder findings Stereo-refraction: Its effect on far-point cylinder findings Gary E. Eudaily Pacific University Jon Elston Pacific University Larry Henningsgaard Pacific University Recommended Citation Recommended Citation Eudaily, Gary E.; Elston, Jon; and Henningsgaard, Larry, "Stereo-refraction: Its effect on far-point cylinder findings" (1967). College of Optometry. 278. https://commons.pacificu.edu/opt/278 This Thesis is brought to you for free and open access by the Theses, Dissertations and Capstone Projects at CommonKnowledge. It has been accepted for inclusion in College of Optometry by an authorized administrator of CommonKnowledge. For more information, please contact CommonKnowledge@pacificu.edu. brought to you by CORE View metadata, citation and similar papers at core.ac.uk provided by CommonKnowledge

Upload: others

Post on 22-May-2022

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Stereo-refraction: Its effect on far-point cylinder findings

Pacific University Pacific University

CommonKnowledge CommonKnowledge

College of Optometry Theses, Dissertations and Capstone Projects

1967

Stereo-refraction: Its effect on far-point cylinder findings Stereo-refraction: Its effect on far-point cylinder findings

Gary E. Eudaily Pacific University

Jon Elston Pacific University

Larry Henningsgaard Pacific University

Recommended Citation Recommended Citation Eudaily, Gary E.; Elston, Jon; and Henningsgaard, Larry, "Stereo-refraction: Its effect on far-point cylinder findings" (1967). College of Optometry. 278. https://commons.pacificu.edu/opt/278

This Thesis is brought to you for free and open access by the Theses, Dissertations and Capstone Projects at CommonKnowledge. It has been accepted for inclusion in College of Optometry by an authorized administrator of CommonKnowledge. For more information, please contact [email protected].

brought to you by COREView metadata, citation and similar papers at core.ac.uk

provided by CommonKnowledge

Page 2: Stereo-refraction: Its effect on far-point cylinder findings

Stereo-refraction: Its effect on far-point cylinder findings Stereo-refraction: Its effect on far-point cylinder findings

Abstract Abstract Stereo-refraction: Its effect on far-point cylinder findings

Degree Type Degree Type Thesis

Degree Name Degree Name Master of Science in Vision Science

Committee Chair Committee Chair Carmichael

Subject Categories Subject Categories Optometry

This thesis is available at CommonKnowledge: https://commons.pacificu.edu/opt/278

Page 3: Stereo-refraction: Its effect on far-point cylinder findings

Copyright and terms of use Copyright and terms of use

If you have downloaded this document directly from the web or from CommonKnowledge, see

the “Rights” section on the previous page for the terms of use.

If you have received this document through an interlibrary loan/document delivery service, the If you have received this document through an interlibrary loan/document delivery service, the

following terms of use apply: following terms of use apply:

Copyright in this work is held by the author(s). You may download or print any portion of this

document for personal use only, or for any use that is allowed by fair use (Title 17, §107 U.S.C.).

Except for personal or fair use, you or your borrowing library may not reproduce, remix,

republish, post, transmit, or distribute this document, or any portion thereof, without the

permission of the copyright owner. [Note: If this document is licensed under a Creative

Commons license (see “Rights” on the previous page) which allows broader usage rights, your

use is governed by the terms of that license.]

Inquiries regarding further use of these materials should be addressed to: CommonKnowledge

Rights, Pacific University Library, 2043 College Way, Forest Grove, OR 97116, (503) 352-7209.

Email inquiries may be directed to:[email protected]

Page 4: Stereo-refraction: Its effect on far-point cylinder findings

1

l

. ~

STEREO-REFRACTION: ITS EFFECT ON FAR-POTh"T C"YI..INDER FINDINGS

,,

~ J

. '

Page 5: Stereo-refraction: Its effect on far-point cylinder findings

)

TABLE OF CONTENTS

Contents: Page mt'llber

Introduction ••••••••••••••••••••••••••••••• ·• ................................. .

Acknowledgements ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

His-tory •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

Procedu.re ••••• , ••••••••• " •••••••••••••••••••••••••••••••••••••••••••••••••••

Ila.ta •••••••••••••••••••••••••••••••••••••••••••••••• ~ ••••••••.•••••••••••••••

(1)

(2)

Table 1•••••• • •••••••••••••••••••••••••··~·•••••••••••• • ••••••••••••

Table 2•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

(J) ·~· Table 3 ••••••••••••••••••••••••••• ~ •••••••••••••••••••••••••••••••••

(4) Table 4••••••••••••••••••••••• • •••••••••••••••••••••••••••••••••••••

Conelusion••••••••••••••••··~···•· ••••••••••••••••••••••••••• • •••••••••••••••

Bibliography••••••••••••••••••~•••••••••••••••••••••••••••••••••••••••••••••

i

ii

1 3

4 5

6- 11

7

8

10

11

12

13

Page 6: Stereo-refraction: Its effect on far-point cylinder findings

' )

INTROI1JCTION

This thesis done in part:i.al fulfillment for the degree of rocrOR

OF 0Pr011ETRY, represents an original research project done by

Gary E. Eudaily, Jon Elston, and Larry Henningsgaa:rd, clinicians

at the College of Optometry, Pacific University, Forest GI~Vev

Oregon.; The research was to detennine what, if ar..y, changes occur

in far point cylinder pouor and/ or axis wher1 obtained by means of

a three-dimensional, st~reo-refra.ction techni.que as co.m:Pared to

those results obtrinGd with the standard, bi-dimensional technique. ~.

)

l j J

Page 7: Stereo-refraction: Its effect on far-point cylinder findings

)

)

ACKNffif.LEOOEt1ENT S

We wish to express our sincere thanks to Dr. Jane Brent Carmichael

who acted as our faculty advisor for this study, and to Dr. Elizabeth Brody

for her many hours of work helping us prepare the statistical analysis

used herein.

ii

Page 8: Stereo-refraction: Its effect on far-point cylinder findings

_,_

} HISTORY:

)

It has been long accepted in optometr,y that L~ equalization of

the two eyes is of utmost importanc~ in influencing binocularity. Almost

as universally accepted is the fact that our methods for achievLng this

balance have been at best rather uncertain. This problem has led to the

innovation of several different optometric techniques designed to elimdnate

this uncertainty.

Turvillel published a description of a tec~~que in 1936 which has

been rather widely accepted in the British Isles, but has not been used to

any great extent here in the United States, mainly because of its slowness.

The Turville system consisted of a test clw.rt with two fields of

letters spaced 60mm apart, set s,t 6m.. This chart "PTaS reflected to e.

patient from a mirr-or placed at a 3m distance. The mirror 1-.'"B.s bisected

by a m~tal or ground glass septu:.111 of )em width. This en~bled the patient

to see one set of letters with his right eye while the other set was seen

with his left eye. A black border arolL~d the chart served as a stimulus

to peripheral fusion, as did the septum. While this set-up served tc;:, -

prov.iaeisome sort of control of binocularity, one can see that M exaggerated

fixation disparity has been created.

The importance of good binocluar balance has been noted by various

other authors; for example, Sugar2 and Shreve3 have both reported that

there may be changes in the axis of monocular astigmatism when binocUlar

1 I. Borish, Clinical -Refraction, pp. 291-293.

2 !:.'1 .• Sugar, "Binocular Refraction with Cross Cylinder," Arch. Ophth, Jan. 1944.

. _J 'J_.R·. ~~h:rc.ve, 11R] hrrl.nation of: Cyclophoria r!"' " faci:.or in Astigmatic " ~ · · Correeti0u. 11 A..'rll. J. Ontom. and Arch. A..rn. Aca.c1:_ S~et.v<r.. e, 1947.

Page 9: Stereo-refraction: Its effect on far-point cylinder findings

vision is o!.. ::!:.i.~::a.. This shift of'. nds may be due to a cyclotorsion of the

eye, when the visual pattern is shifted from a mvnocular con(i".ion to a

binocular condition.

Norman4 has found a significant difference in binocular plus acceptance

from that found monocularly. He has utilized polaroid filters and speciallY

designed charts, usable for test procedures from equalization to stereopsis.

Polaroid filters have also been used by WilmutS to modif.y the Turville

technique. Since the chart is polarized, no septum is needed, and

peripheral fusion is obtained by unpolarized borders on the chart.

Several different charts were used, all of which created some kind of

fixation disparity.

Copel.ar~6 proposed that the a.ddi tion of a 2. 00 sphere, over the

retinoscopic finding be added before the eye not being tested. This blur

would allo't-J proper fixation, but would destroy the possibility o:f acute

discrimination through this eye.

Luckeish and Mcss7 developed a similar procedure using a neutral

filter to destroy acute discrimiria.tion rather th.!Ul a plus lens.. The

basic objection to both of these methods is that it is impossible to m.ake

a rapid shift from one eye to the other.

- One of the most recent advances in binocular refraction is the

4 S.L. Norman, ''Binocular Subjective Reft·action With the Polaroid Occluder," QEt, Week1z, Nov. 9, 19.50.

5 E.B. Wilmut, "The Use of Polarizing Filters for Infinity Balance Ex!mi- · nation and Near Correction,." Trans. In1::.t.. ,O:et,,...9or£., 19.51.

~ J'.C. Copeland, Locating the Astigmatic Axis ur'.der Binocular Fixation, Ten Years of gptical DeveloE!J1e~ts, Nov. 1940.

7 M. Lucke~.sh a:r~ F .K. Moss, "A Ne-w. Method of Subjective Refraction In-TOlving J::.antical Tec:1.niques in S.'b.t\~ and ))ynar.tio Tests," Arch, Ophth, •l<OI.j, 1940.

Page 10: Stereo-refraction: Its effect on far-point cylinder findings

-3-

dev<'-lt pnent of stereoscopic slides. Frantz8 refers to this method as ~: :~ ·

most suitable binocUlar refrac~irm technique ever developed for use in the

modern optometric office. It was from this tec~ique of using polarized

stereo slides and polarized acuity :me.terial that our O"t-m binocular refraction

technique was developed.

)

p ,- r·m A. Frantz, "A Revier.R of Three-Dimensional Refraction," The Optometri_s:. ·

- 'Week:i..u pp. 23-)0. ,.

Page 11: Stereo-refraction: Its effect on far-point cylinder findings

) Eli09~:

AJ~ e~ations were done in a standard brenty-foot refracting room

using an A.O. Rx-Master. The bi-dimensional refractions were done in the

manner customari~ used at the College of Optometry, Pacific University.

Those refractions consisted of a 20/30 blur finding, starting from a high

fog; a clock dial cylinder test; a Jackson cross cylinder test, used to

refine the clock dial; and a red-green balance test for monocular sphere

power.

Refractions dona under both sets of conditions were accomplished with

the use of polaroid controls. We found it easier to construct our cr.m

polaroid filters and sn.a.lyzers out of sheet polaroid, as there a:re

very .few cormnerci.ally available deviC!es that were sui table for our purposes.

The entire set-up consisted of five pieces of sheet polar6id: one over

) each lens-well on the phoropter (90 degrees removed from ea;h other);

one over each tube of the stereo slide projector (90 degrees removed from

each other and oriented to coincide with those on the phoropter); and

finally one over the standard A.Oa projector that we used for the acuity

material and clock dial, etc. This last polaroid was constructed so that it

could be rotated on the end of the projector tube and in this manner could

be used to present a clock di.e.l, for example, polarized in such a manner

that only the right eye could see it, even though an entire polarized

stereo slide was being viewed bi..TJ.ocUJ.arly.

The atereo slides used for this study were taken specifically for this

-4-

use by the clinicians. They consist most~ of outdoor scenes. We found that

this was necessar,y to achieve the desired depth effect. We found that

any of the various kinds of outdoor slide film 'J'"'rk~..:t · .• ~:l.C:or c.n- purposes. )

However, lla clet:;id~<! to use Ectachrome X sr! a Kodak .:tereo Cam~ra.

Page 12: Stereo-refraction: Its effect on far-point cylinder findings

-5-

Extreme cal"e was taken to tr; to eliraina.te any effect induced by our

refraction procedure itself. Patients were selected at random from both

the student body at Pacific University and from the usual out-pa.tient

clinic at the College of Optometr,y at Pacific. Random ch~~ce determined

which of the two refraction techniques was to be used first--ie: some

patients were tested using the stereo conditions first and others using

' standard bi-dimensional techniques. Refractive errors wel'e not considered

in the selection of patients--they ranged from a 4.50 diopter myope to a

5.00 diopter hyperope, with most patients grouped closer to the mean

of a random sample of the population.

)

J

I J j

I

Page 13: Stereo-refraction: Its effect on far-point cylinder findings

J

)

)

-6-·

It becomes immediately app~t·Emt when looking g,t '£ables 1 and 2 that

there have been some gross ch~nges in results in shifting from bi-dU.1ensior~l

refraction techniques to stereoscopic ones. It is almost as immediately

notic~able that the changes i.."'l. cylinder axis that have occurred are quite

insignificant. In fact, in the majority of cases, no cru.u1ge in axis or a

change of only 2-J degrees has occurred. Quite obviously the major change

that is observed is the change of cylinder power.

At first gltJ.nca, the data in Tables 1 8lld 2 seems to reveal an

extre::nely clear-cut picture: in most instances there appears a slight

increase in minus cylinder power usir~ the stereoscopic refraction techniques

we developed. There also seems to be a. defi.ni te correlation between right

and left eyes. A statistical evalliati6n, .however, shows that this is not

the c:Ase.

Table 3 shows that the approximate mean change for both the left and

right eyes was +.25 diopters, but that a change in the cylinder power in

the left eye was not at all related to a. change of pol-rer in the right eye.

(We have assigned a plus (+) value to those cases that took more minus

cylinder under stereoscopic conditions.)

The lack of correlation bstween the right ar..d left eyes in the matter

ot cylinder po1-rer is the most disturbing item we uncovered. This prompted.

us to do a more complete analysis of the data in this area. which led to the

results sho'Wll in Table 4.

Page 14: Stereo-refraction: Its effect on far-point cylinder findings

• +

Patient I

1 2 3 4 5 6 7 8 .. 9

10 11 12 13

) 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

]. ..

·.

PATIENTS SijOHING A CHA.IDE OF CYUNDER PO\VER ON THE J .c. c.

RIGHT EYE

Bi-dhnensiohal

-75 X 32 p1

-3.25 X 180 p1

-.62 X 150 -1.00 X 3 -3.50 X 4 ~37 X 25 -.so x 90 -1.00 X 175 -.25 X 88 -1.00 X 90 -.50 X 105 -.25 X 165 -.25 X 180 -.37 X 56 -1.00 X 163 -.50 X 90

p1 p1

-.37 X 75 -1.00 X 100 -1.00 X 55 p1

-1.50 X 85 -.25 X )0 -4.75 X 180 -.25 X 95

Variance, s = 0.219

Tee score = 5.94

(n-1) = 27

TABLE 1

Stereoscopic E.9.li.~r Differ-:mc!:!.

-1.12 X 25 +.375 -.25 X 160 +.25 -3.75 X 3 +.50 pl o.o

-.so x 153 -.125 -1.37 X 5 +.3?5 -3.25 X 5 -.25 -1.00 X 23 +.625 -1.00 X 93 +.50 -1,25 X 170 +.25 -.75 X 88 +.so -1.25 X 90 +.25 -.87 X 100 +.375 -.37 X 165 +.125 -.37 X 175 +.125 -.62 X ,54 +.25 ..;1.25 X 167 +.25 -1.00 X 94 . +.50 -.so x 90 +.50 -.25 X 160 +.25 -.so x 75 +.1?5 -1.25 X 90 +.25 -1.25 X 47 .. +.25 -.so x 175 +.50 -1.25 X 85 -.25 -.so x 32 +.25 -4.87 X 180 +.125 •.)7 X 90 +.125

Mean Difference = +.2500

I 11:. ,. .... _~

~7-

Page 15: Stereo-refraction: Its effect on far-point cylinder findings

-8-

PATIENTS SHCYNING A CHANLiE OF CYUNDER PCMER ON THE J .c.c.

LEFI' EY;E

Patient ft. Bi-dimensional Stereosco,;eic Power Difference

1 -.50 X 165 •.75 X 163 +.25 2 pl -.12 X 70 +.125 3 -1.62 X 180 -2.25 X 180 +.625 4 p1 -.25 X 48 +.25 5 -1.00 X 25 -1.25 X 27 +.25 6 -1.00 X 180 -1.37 X 1 +.375 ? -3.25 X 180 -3.50 X 175 +.25 8 -.75 X 180 -.87 X 180 _.125 9 -.50 X 93 -1.00 X 92 +.50

10 pl p1 o.oo 11 -.25 X 115 . -.75 X 120 +.50 12 -1.00 X 90 -1.25 X 90 +.25 13 -.50 X 50 -.75 X 50 +.25 14 pl -.37 X 5 +.)75 15 -.25 X 171 -.37 X 170 +.125 16 -.50 X 92 -.75 X 93 +.25 17 -~75x25 -1.00 X 40 +.25 18 -1.00 X 60 -1.25 X 61 +.25

) 19 p1 -.25 X 97 +.25 20 -.25 X 155 -.50 X 150 +.2.5 21 -.50 ·X 50 -.62 X 35 +.125 22 p1 pl o.oo 23 -1.50 X 165 -1.75 X 160 . +.25 24 -.50 X 5 :..75 X 180 +.25 25 -1.00 X 85 -1.25 X 86 +.25 26 -.37 X 5 -.87 X 5 +.50 27 -3.25 X 160 -3.50 X 165 +.25 28 -.25 X 81 p1 -.22

Mean ~.fference = +.246

Variance, s = 0.155

Tee score :: 8.25

(n-1)= 27 .·

} TABLE 2 ·

Page 16: Stereo-refraction: Its effect on far-point cylinder findings

)

)

-9-

Table 4 1~ .., g~-ouped frequency , H ,.;tribution showing the portion of the

population requiring more than +.25 diopters of minus cylinder '\.lliJer stereo­

scopic conditions, that portion requiring +.25 diopters and that portion requiring

less than +.25 diopters, for each ~~e. Again, this illustrates that there

is nci relationship between right and left eyes when the data is grouped around

the median figure; however, a relationship does exist between right and left

eyes when the data is at the extremes, (above and below].

This data was again computed in the form of a chi squared equation in order

to determine the significance of the relationship between right end left eyes

with the data grouped around the extremes. Chi squared = 2.630. ~Vith tHo

degrees of freedom, the chi squared required to be significant at the five

percent level of probability is 5.99. Obviously the chi squared computed on our

data is not statistically significant. It is our contention, however, that a

significant relationship w~uld exist if a larger sample of patients were used.

In our sample there are 28 patients. A population of approximately twice the

number of patients shoUld show the relationships we have talked about.

The ttttt scores shown in Tables 1 and 2 indicate that this data on change

in cylinder power is significant at well beyond the 0.1% level of probability -­

ie: there is less than a one in a thousand cha."lce that the results could :b..a.ve

been obtained by chance. From this we can definitely say that when comparing

stereoscopic refraction to bi-dimensional refraction there is the highest

probability that the patient will require more minus cylinder power under

stereoscopic conditions with a mean value of about .25 diopters.

Page 17: Stereo-refraction: Its effect on far-point cylinder findings

-10...

)

o.s.

+ .. 75 - . JiO - . ,?,~; .... ?l:; .1 g (l +.1? ~ :t..-~37: ~" ~~!:!5-~? .

I '

5

I I I .

+.625 ' I

I 1

+.50 I ·

1

1111 11 1 ' . ' ..

+.375 11 1 I I

' ..

+ .. 25 ' 11 1 11 1 ; ~11 -

O.D. +.125 ' I I ' 1 11 11 I 1 :

' - -

) 0 1 I

I ..

_,.. .. ' -

-~125 I I

1 I -

.

-.25 I . I

' 11 I ' I I I

' I

-.375 I '

' I I. ' .. .. ..

'

-.50 I I

. ,,

~~\BLE 3

Page 18: Stereo-refraction: Its effect on far-point cylinder findings

}

O.D.

above .2.5

.25

below· .2.5

total OS

I

below . 2.5

1

'

' -

7

.25 I

5

I

s

s I

I 15

o.s. above total

.2.5 OD

4 10

1 9 I I

I

---I I I

1 9

- --

6

Chi squared = 2.6JO. with two degrees of freedom.

TABLE 4

-11-

I

Page 19: Stereo-refraction: Its effect on far-point cylinder findings

'

)

CONCLUSION:

It has long b~en the contention of those using stereoscopic refraction

techniques that these techniques more nearly represent the normal everw:r-day

seeing envirorun~nt. It is not our purpose in this research thesis to

attempt to m?ay anyone's view on this particular point; rather, to tr,y to

inform practitioners using either technique that a significant difference in

results does exist. It is up to the individual practitioner to decide

which refraction technique will best serve his patients' needs.

It is our genuine hope that this thesis may, in some way, be a worth­

while addition to the accmuulated knowledge of the profession to which

we dedicate our services.

Gary E. E-adaily

Jon Elston

Larr.y HerJUngsgaard

Page 20: Stereo-refraction: Its effect on far-point cylinder findings

BIBIJ:OGRAPHY

t

1. Berish, I., Clinical Refraction. Professional ~re'&'S Inc. 2nd ed.

2. Copeland, J .c., "Locating the Astigmatic Axis under Binocular Fixat-ion, Ten Years of Optical Developnents~' (Nov. 1940), Riggs Optical Co, Chicago, 1942.

). Morgan, Meredith W. Jr., 11The Tl.l.rV'ille Infinity Binocular Balance Test, 11

Juneric~ Journel of Opt. and Arch. of American Academy of Optometry, June, 1949. .

4. Norman, S.L., '~inocular Subjective Refraction With the Polaroid Occluder," QE.t. Weekl.:z:, November 9, 1950.

5. Shreve, J .R., "Eliniination of Cyclophoria as a Factor in Astigmatic Correction," fin.• J, Optom •. and Arch • . Am. Aca.d~ ,9ptom., 24:598; 1947.

6. Sugar, H.S., "Binocular Refraction with Cross Cylinder," Arch Ophth, )1:)4, Jan. 1944.

7. Wilmut, E.G., "the Use of Polarizing Filters for Infinity Balance E......a.mination

-13-

) and Near Correction," Trans. Int. Opt. Cong. Br. Opt. Assoc, Longon, 1951.

8. Frantz, Ixm A., "A Review of Three-Dimensional Refraction," The Optometric WeeklYt· Jan-. 6, 1966. ''

9. Luckeish, M. and F .r. Moss, "A New Method of Subjective Refraction Involving Identical Techniques in Static and Dynamic Tests," Arch, Ophth, 2):941-56.

j

I ! J