steelmaking electric arc furnaces (eafs): canadian ... · page 1 revision 2007/01/17 steelmaking...

31
Page 1 Revision 2007/01/17 Steelmaking Electric Arc Furnaces (EAFs): Canadian Experience in Measurement, Standards Development and Reduction of Emissions www.ec.gc.ca Case Study - Gerdau Ameristeel, Cambridge, Ontario, Canada Presented by Patrick Finlay, Environment Canada at Workshop on Emissions Reductions North American Commission for Environmental Cooperation (NACEC) Monterrey, Mexico January 31 st and February 1 st , 2007

Upload: phamcong

Post on 05-May-2018

221 views

Category:

Documents


1 download

TRANSCRIPT

Page 1

Revision 2007/01/17

Steelmaking Electric Arc Furnaces (EAFs): Canadian Experience in Measurement, Standards

Development and Reduction of Emissions

www.ec.gc.ca

Case Study - Gerdau Ameristeel, Cambridge, Ontario, Canada

Presented byPatrick Finlay, Environment Canada

atWorkshop on Emissions Reductions

North American Commission for Environmental Cooperation (NACEC)

Monterrey, MexicoJanuary 31st and February 1st, 2007

Page 2

Revision 2007/01/17

Contents

• Contexts• Existing and Modified Facilities• Performance Data• Lessons Learned• Conclusions• References• Acknowledgments

Page 3

Revision 2007/01/17

Contexts

• Canadian Environmental Protection Act (CEPA 1999) –Virtual Elimination of Persistent Bioaccumulative Toxics (PBTs)

• Canadian Council of Ministers of Environment (CCME), Canada-wide Standards (CWS) for Dioxins and Furans Emissions from Steel Manufacturing Electric Arc Furnaces (EAFs)

• United Nations Environment Programme (UNEP) Stockholm Convention and Unintentionally produced Persistent Organic Pollutants (UPOPs) National Action Plan (NAP) requirements

Page 4

Revision 2007/01/17

Canadian Iron and Steel Facilities

Gerdau Ameristeel,Cambridge, Ontario

Page 5

Revision 2007/01/17

Company Profile

• Gerdau Ameristeel, Cambridge, Ontario (The Gerdau Group (Brazil) is the majority shareholder)

• Electric Arc Furnace, 43 ton capacity• Recycles post-consumer and industrial metal to

produce steel squares, rounds, angles, unequal angles, flats, channels, rebar

• Operates on a seven day, 24 hour basis employing approximately 280 hourly and salaried staff

Page 6

Revision 2007/01/17

Electric Arc Furnace (EAF)

Add a Photo here

Feed: steel scrap

Air emissions: Particulate Matter (PM),Nitrogen Oxides (NOx), Volatile Organic Compounds (VOCs), Carbon Monoxide (CO), Carbon Dioxide (CO2), Dioxins/Furans (PCDDs/PCDFs)

Secondary

steelmaking

Page 7

Revision 2007/01/17

Previous Emissions Management System

Page 8

Revision 2007/01/17

New Emissions Management System

Page 9

Revision 2007/01/17Overview of the New Emissions Management

System (1)

Melt Shop

Stack

Baghouse

Page 10

Revision 2007/01/17Overview of the New Emissions Management

System (2)

EAF: Electric Arc Furnace

Page 11

Revision 2007/01/17

Sampling and Analyses

• Test program teams (2005)– Plant Environmental Manager (1)– Local Ontario Ministry of the Environment (MOE) Abatement Officer (1)– MOE Source Assessment Officer (1)– Sampling company staff (LEHDER Environmental Services Ltd.) (5)– Analytical laboratory (1)

• Reference methods– Sampling: Environment Canada (EC) report EPS 1/RM/2, June 1989– Analysis: EC report EPS 1/RM/3, May 1990– Quality Assurance: EC report EPS 1/RM/23, October 1992– Test Protocols: Ortech Environmental Report #30121

• ProceduresDevelop test protocol Determine concentration and mass rate Analysis Report

Page 12

Revision 2007/01/17

EAF Baghouse and Exhaust Stack

Source: LEHDER Environmental Services Ltd.

Page 13

Revision 2007/01/17

Tests Conducted in Recent Years

• Sampling companyLEHDER Environmental Services Ltd.

• Test dates– November 2005 (new baghouse)– April 2004 (new baghosue, after system adjustment)– December 2003 (new baghosue, performance test #2)– September 2003 (new baghosue, performance test #1)– May 2002 (old baghouse)– August 2000 (two tests, old baghouse)– April 2000 (old baghouse)

• Data assistanceEmissions Research and Measurement Division (ERMD), Environmental Technology Center (ETC), Environment Canada

Page 14

Revision 2007/01/17

Emissions Performance Data: Dioxins/Furans Concentrations (2000-2005)

CWS: Canada-wide StandardsLoQ: Level of Quantification

0

20

40

60

80

100

120

140

160

180

200

1999 2000 2001 2002 2003 2004 2005 2006

Year

Emis

sion

con

cent

ratio

n (p

g IT

EQ/R

m3)

CWS 2006 Limit

CWS 2010 Limit

LoQ

Page 15

Revision 2007/01/17

Emissions Performance Data: Dioxins/Furans Emissions to Air (2000-2005)

Data source: Environment Canada, National Pollutant Release Inventory (NPRI), http://www.ec.gc.ca/pdb/npri/npri_home_e.cfm

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

1999 2000 2001 2002 2003 2004 2005 2006

Year

D/F

em

issi

ons

to a

ir (g

ram

)

Page 16

Revision 2007/01/17Emissions Performance Data: Dioxins/Furans

Environmental Performance Indicators (EPI)(2000-2005)

Data source: Environment Canada, National Pollutant Release Inventory (NPRI), http://www.ec.gc.ca/pdb/npri/npri_home_e.cfm

0

0.5

1

1.5

2

2.5

3

3.5

1999 2000 2001 2002 2003 2004 2005 2006

Year

EPI (

mic

rogr

am T

EQ/T

onne

)

Page 17

Revision 2007/01/17

Emissions Performance Data: Total Particulate Matter (TPM) Concentrations (2000-2005)

UNEP: United Nations Environment Programme BAT: Best Available TechniquesBEP: Best Environmental Practices

0

1

2

3

4

5

6

7

8

9

10

11

12

13

1999 2000 2001 2002 2003 2004 2005 2006

Year

Emis

sion

con

cent

ratio

n (m

g/R

m3)

Proposed in Code of Practice

UNEP BAT/BEP Guideline

Page 18

Revision 2007/01/17

Emissions Performance Data: Total Particulate Matter (TPM) Emissions to Air (2002-2005)

Data source: Environment Canada, National Pollutant Release Inventory (NPRI), http://www.ec.gc.ca/pdb/npri/npri_home_e.cfm

0

10

20

30

40

50

60

70

2001 2002 2003 2004 2005 2006

Year

TMP

emis

sion

s to

air

(Ton

ne)

Page 19

Revision 2007/01/17Emissions Performance Data: Total Particulate Matter (TPM)

Environmental Performance Indicators (EPI) (2002-2005)

Data source: Environment Canada, National Pollutant Release Inventory (NPRI), http://www.ec.gc.ca/pdb/npri/npri_home_e.cfm

0

0.05

0.1

0.15

0.2

0.25

2001 2002 2003 2004 2005 2006

Year

EPI (

kg/T

onne

)

Page 20

Revision 2007/01/17

Landfill Gas Fuel Use

Source: Environment Canada, http://www.environment-canada.ca/nopp/lfg/en/issue9.cfm

Page 21

Revision 2007/01/17

Landfill Gas Fuel Use

Source: Natural Resources Canada,http://www.canren.gc.ca/renew_ene/index.asp?CaID=47&PgID=1136

This photograph shows the Cambridge landfill gas collection building in the foreground and the Gerdau Ameristeel plant in the background behind the trees.

• LGF provided about 32% of the reheat furnace energy use in 2000 • Reduced GHG emissions by 118,000 tonnes of eCO2 per year,

- equivalent of taking 17,000 cars off the road per year

A view of the landfill gas collection facility and the flare at the Cambridge landfill. The flare is not actually burning the gas,but it is required as a backup.

Page 22

Revision 2007/01/17

Lessons Learned (1)

• Design specifications (performance guarantees) – Dioxins/Furans: < 100 pg/Rm3 (I-TEQ*)– Total Particulate Matter: < 5 mg/Rm3

• Awarded contract to DECOS (Italy), Division of Voest Alpine (Austria)• Design included

– Improved EAF hood capture (doubled fan capacity)– Post combustion chamber – Cooling tower rapid quench – Induced draft fans (Three - 50% capacity) – High efficiency filter fabric bag houses (16 units)– Broken bag detectors– Stack sampling deck and jib– 35 m stack

* I-TEQ: International Toxic Equivalent

Page 23

Revision 2007/01/17

Lessons Learned (2)

• Commissioning was challenging– Baghouse temperature now controlled to 80 Degrees C

(was higher and DF vaporized)– Increased cakes on fabric filters

• EAF dust sent to secure hazardous waste disposal site (Trials to pelletize and reuse in EAF)

• Costs – Air Pollution Control System - $10 million– Dioxins and Furans Stack Tests - $25 k– Dioxins and Furans Dust test - $900

Page 24

Revision 2007/01/17

Other Best Environmental Practices

• Paved yard for feed and waste storage with drains, and oily water separators

• Covered building for slag cooling to control fugitive dusts

• Dispersion modeling for all sources for Ontario Point of Impingement predictions

• Acoustic Enclosure buildings, Silencers etc for noise sources - good neighbours

• Ultra clean baghouse building!

Page 25

Revision 2007/01/17

Baghouse (Cleanest place in plant!)

16 units in total

Dust conveyor

Page 26

Revision 2007/01/17

Conclusions

• Co-benefits of Canada wide Standards (CWS) implementation– Surpassing CWS requirements– Reduced process fugitives and worker exposure in EAF melt shop– Improving understanding of D/F formation, prevention and control

• Factors to consider– Feed quality– Temperatures– Residence times– Filter fabric performance– System design, operation and maintenance

• Achievable Performance Levels (APL) – 100 pg/Rm3 I-TEQ* achievable – 32 pg/Rm3 I-TEQ Level of Quantification achieved

* I-TEQ: International Toxic Equivalent

Page 27

Revision 2007/01/17

Acknowledgements

• Gerdau Ameristeel• Bob Downie

Corporate Environmental ManagerHopkins Street SouthWhitby, OntarioL1N [email protected]

Page 28

Revision 2007/01/17

Further Information

• Hui Peng, Program Engineer, Metals, Cement and By-product Organics Section, Pollution Prevention Directorate, Environment Canada- [email protected]

• Patrick G. Finlay, P.Eng., Senior Advisor, Industrial Sectors Environmental Performance, Environment Canada- [email protected]

Page 29

Revision 2007/01/17

References (1)

• Canadian Council of Ministers of the Environment (CCME), Canada-wide Standards for Dioxins and Furans: Steel Manufacturing Electric Arc Furnaces, March 2003, www.ccme.ca.

• Canada’s National Implementation Plan (NIP) under the Stockholm Convention on Persistent Organic Pollutants, Part II: Canada’s National Action Plan (NAP) on Unintentionally produced Persistent Organic Pollutants (UPOPs), May 2006, http://www.pops.int/documents/implementation/nips/submissions/default.htm

• Canadian ORTECH Environmental Inc., “A Review of Dioxin/Furan Test Results from Canadian EAFs for Canadian Steel Producers Association”, Report 30121.

• Environment Canada, “Reference Method for Source Testing, Measurement of Release of Selected Semi-Volatile Organic Compounds from Stationary Sources”, Report EPS 1/RM/2, June 1989.

• Environment Canada, “A Method for the Analysis of Polychlorinated Dibenzo-para-Dioxins (PCDDs), Polychlorinated Dibenzofurans (PCDFs) and Polychlorinated Biphenyls (PCBs) in Samples from Incineration of PCB Waste”, Report EPS 1/RM/3, May 1990.

• Environment Canada, “Internal Quality Assurance Requirements for the Analysis of Dioxins in Environmental Samples”, Report EPS 1/RM/23, October 1992.

Page 30

Revision 2007/01/17

References (2)

• Environment Canada, National Pollutant Release Inventory (NPRI),http://www.ec.gc.ca/pdb/npri/npri_home_e.cfm

• Environment Canada,http://www.environment-canada.ca/nopp/lfg/en/issue9.cfm

• LEHDER Environmental Services Limited, “Evaluation of Dioxins and Furans from the EAF Baghouse Stack at the Gerdau Ameristeel Mill in Cambridge, Ontario”, Project number 052314, February 2006.

• Multi-pollutant Emission Reduction Analysis Foundation (MERAF) for the Iron and Steel Sector, Final report, September 2002.

• Natural Resources Canada, http://www.canren.gc.ca/renew_ene/index.asp?CaID=47&PgID=1136

• United Nations Environment Programme (UNEP) draft guidelines on best available techniques and best environmental practices (BAT/BEP) under the Stockholm Convention on Persistent Organic Pollutants, http://www.pops.int/documents/batbep_advance/intersessional_work/draft_guide.htm

Page 31