station mirrier -2011
DESCRIPTION
Indian RailwaysTRANSCRIPT
STATION MIRROR RECORD (SIGNAL) OF CNBI STATION-2011
S.No.ItemsDescription
1.Name of StationCNBI
2.ClassB Class
3.Up & Dn./Line Position (with common loop position) -Description
Line No.
Dn. Loop Line
--
Dn. Main Line
02
Up Main Line
03
Up Loop Line
--
Common Loop Line
01, 04 & 05
Others Line
--
Type of SignallingColour Light Signal
Panel InterlockingPI
Auto Route SettingYES
Route Relay
InterlockingPanel Interlocking (British), Auto Route Setting Type
Hybrid Signalling--
Mechanical Signalling--
4.Type of InterlockingStandard III Interlocking
Central Panel/End Panel/CabinCentral Panel
Type of PanelDomino Type
Make--
Date of Installation24/09/2004
5.Indication Position LED/LampLED Type
6.Track CircuitsDC Single Rail Track Circuit
Total nos. of
Track circuits63 Nos.
Type of G/Joints, RDSO JointsDescription
60Kg.
52 Kg.
90R
Total
G/Joint
221
--
--
221
RDSO/Joint
08
03
--
11
7 .L-Xing Gate PositionDescription
Interlocked
Non-interlocked
G-79D,77B,78B
--
Interlocked with
CNBI Panel
--
Communication
CNBI Panel
--
Location
-
--
8.SI-26 Position (Signal Failure) 03 Years Comparative/01 Year Branch wise/Cause wiseAnnexure attached
9.New Work if any
Sanction work details--
Work in progress--
Work recently done CNBL-CNBI Automatic Block Signalling work in 2009
10.Jt Pt. & Xing insp. Annexure attached
01 Year position with date & pending items
CNBI
11.Accidents Position
On S&T AccountNIL
On Other branchNIL
12.Lever Frame PositionDescription
Gate79D
Type of LF
GF Type
Total/Spare Nos. of levers
03/01 Nos.
DOH
24/09/2004
DOT
06/09/2006
13.B/Instt. PositionDescription
E/Side
W/Side
Connected with
CHK W/C
--
Type
PTJ
--
S.No.
2503
--
DOH
Jan. 2006
--
DOI
31.01.2007
--
Due O/H
Jan 2013
--
14.Relay Position
(Periodicity of O/H of Relays)
Track 10 Yrs. ] As per
Line 12 Yrs. ] Div.
TR 12 Yrs. ] As per
Line 15 Yrs.] SEM IIDescription
Track Relay
Line Relay
Type
Shelf
Q
Shelf
Q
Other
Total No.
--
63
--
1299
76
Due in 10-11
--
--
--
--
--
Replaced till date
--
--
--
--
--
Balance
--
--
--
--
--
15.SI-4 Position 01 yearAnnexure attached
Gears overdue for maintenance with SI-4 during last 06 months
16.Implantation of SignalAnnexure attached
17.Painting DetailsApril 2010
18.
Earth testing detailsDescription
B/Instt.
W/Side
IPS
Cable-2
Cable-1
DOT
08/06/06
08/06/06
08/06/06
08/06/06
Resistance
04.7 ohm
02.7 ohm
04.7 ohm
04.9 ohm
Due on
June-11
June-11
June-11
June-11
19.
No load currents position
Below 20 maLED Signal provided
Above 20 maNIL
20.Staff Posted
SSE/SE/JE01
MCM/ESM03
MCM/MSM01
F/Gang position--
Helper position04
Vacant position--
21.Training position
Over due refresher course if any--
22.Block Working position
With Track circuitAutomatic block working CNB-CNBI, & CNBL-CNBI
With B/InsttWith Double line PTJ Make B/Instt. CNBI-CHK Side
With Axle counter--
S/Line-D/Line workingDouble Line Absolute & Automatic block working
CNBI
23.Power Supply Position
Total Battery SetDescription
12V
24V
60V
110V
Internal
--
--
-
01
External
--
--
--
--
Others
--
--
--
--
Total
--
--
--
01
Total Track Battery136 Nos.
IPS PositionSTATCON Make Working with 110V AMARAJA Batt. set
24.Cable Position
Total Cable410 Nos.
Main Cable185 Nos.
Tail Cable225 Nos.
STATION MIRROR RECORD (SIGNAL) OF CNBL STATION - 2011S.No.ItemsDescription
1.Name of StationCNBL
2.ClassB Class
3.Up & Dn./Line Position (with common loop position) -Description
Line No.
Dn. Loop Line
--
Dn. Main Line
01
Up Main Line
02
Up Loop Line
--
Common Loop Line
--
Others Line
Up Through Line
Type of SignallingColour Light Signal, Electro Mechanical
Panel Interlocking--
Auto Route Setting--
Route Relay
Interlocking--
Hybrid SignallingYES
Mechanical Signalling--
4.Type of InterlockingStandard III Interlocking
Central Panel/End Panel/Cabin--
Type of Panel--
Make--
Date of Installation--
5.Indication Position LED/LampLamp Type
6.Track CircuitsDC Single Rail Track Circuit
Total nos. of
Track circuits27 Nos.
Type of G/Joints, RDSO JointsDescription
60Kg.
52 Kg.
90R
Total
G/Joint
33370474RDSO/Joint
2503--28
7 .L-Xing Gate PositionDescription
Interlocked
Non-interlocked
G-79B,86B
--
Interlocked with
CNB P/C
--
Communication
CNB P/C, CNBL
--
Location
-
--
8.SM Slide Frame
PositionDescription
Position
Type
--
Make
--
Total/Working
--
DOI
--
DOH
--
DOT
--
9.SI-26 Position (Signal Failure) 03 Years Comparative/01 Year Branch wise/Cause wiseAnnexure attached
CNBL
10.Joint Pt. & Xing inspection Annexure attached
01 Year position with date & pending items
11.Accidents Position
On S&T AccountNIL
On Other branchNIL
12.Lever Frame PositionDescription
CNBL Cabin
G86D
Type of LF
Direct Type
GF Type
Total/Spare Nos. of levers
42/NIL
03/01Nos.
DOH
22.10.2010--DOT
20.11.2010--
13.B/Instt. PositionDescription
East End
W/C
Connected with
--
--
Type
--
--
S.No.
--
--
DOH
--
--
DOI
--
--
Due O/H
--
--
14.Relay Position
(Periodicity of O/H of Relays)
Track 10 Yrs. ] As per
Line 12 Yrs. ] Div.
TR 12 Yrs. ] As per
Line 15 Yrs.] SEM IIDescription
Track Relay
Line Relay
Type
Shelf
Q
Shelf
Q
Other
Total No.
022510878NILDue in 10 -11NILNILNILNILNILReplaced till date
----------Balance
NIL
NIL
NIL
NIL
NIL
15.SI-4 Position 01 yearAnnexure attached
Gears overdue for maintenance with SI-4 during last 06 months
16.Implantation of SignalAnnexure attached
17.Painting DetailsDec-2010
18.
Earth testing detailsDescription
LF
Cable
DOT
20.01.11
20.01.11
Resistance
5.6 ohms
5.5 ohms
Due-on
Jan-12
Jan-12
19.
No load currents position
Below 15 maAll Signals.
Above 15 maNIL
20.Staff Posted
SSE/SE/JE--
MCM/ESM01
MCM/MSM01
F/Gang position--
Helper position03
Vacant position--
21.Training position
Over due refresher course if anyNIL
CNBL
22.Block Working position
With Track circuitWith Continuous Track Circuit GMC Side
With Track circuitWith Automatic Block Signalling. CNBI Side
With Axle counter--
S/Line-D/Line workingDouble Line Automatic block working
23.Power Supply Position
Total Battery SetDescription
12V
24V
60V
110V
Internal
01
01
-
--
External
01
01
--
--
Others
--
--
--
--
Total
02
02
--
--
Total Track Battery 77 Nos.
IPS PositionNIL
24.Cable Position
Total Cable170 Nos.
Main Cable60 Nos.
Tail Cable110 Nos.
STATION MIRROR RECORD (SIGNAL) OF CNB/RRI STATION
S.No.ItemsDescription
1.Name of StationCNB/RRI Commissioned on 11.09.2009
2.ClassSpl Class
3.Up & Dn./Line Position (with common loop position) -Description
Line No.
Dn. Loop Line
--
Dn. Main Line
--
Up Main Line
--
Up Loop Line
--
Common Line
PF L/No. 1 to 11 with Dock PF
Others Line
North, South, 3rd, 4th And 5th line towards GMC side
Type of SignallingMulti Aspect Colour Light Signal with LED lamp
Panel Interlocking--
Auto Route SettingYES
Route Relay
InterlockingRoute Relay Interlocking (Siemens), Auto Route Setting Type
Hybrid Signalling--
Mechanical Signalling--
4.Type of InterlockingStandard III Interlocking
Central Panel/End Panel/CabinCentral Panel
Type of PanelSiemens Domino Type
MakeSiemens
Date of Installation11.09.2009
5.Indication Position LED/LampLED/Lamp Type
6.Track CircuitsDC Single Rail Track Circuit
Total nos. of
Track circuits182 Nos.( 161 CNB/RRI + 21 Diversion line)
Type of G/Joints, RDSO JointsDescription
60Kg.
52 Kg.
90R
Total
G/Joint
5565
--
120RDSO/Joint
75
156
157
388
7 .L-Xing Gate PositionDescription
Interlocked
G83D,82D,42,43 & 45 Spl.
Interlocked with
CNB Panel
Communication
CNB Power Cabin
Location
Div/Line & CPB
8.SM Slide Frame
Position (At L-Xing gates 45, 43, 42 Spl.) for slotting of SignalsDescription
Position
Type
Modified
Make
G-45/PTJ G-43/PTJ G-42/PTJ
Working/Spare
05/03 Nos. 05/03 Nos. 05/03 Nos.
DOI
12.08.07 13.08.07 15.08.07
DOH
20.01.11 20.01.11 23.02.11DOT
20.02.11 21.02.11 05.04.11
9.SI-26 Position (Signal Failure) 03 Years Comparative/01 Year Branch wise/Cause wiseAnnexure attached
CNB10.New Work if any
Sanction work details--
Work in progress--
Work recently doneLED Type Signal provided in Diversion Line& Main Signal in RRI. Yard
11.Joint Pt. & Xing inspection Annexure attached
01 Year position with date & pending items
12.Accidents Position
On S&T AccountNIL
On Other branch--
13.Relay Position (Periodicity of O/H of Relays)
Track 10 Yrs. ] As per
Line 12 Yrs. ] Div.
TR 12 Yrs. ] As per
Line 15 Yrs.] SEM IIDescription
Track Relay
Line Relay
Type
Shelf
Q
Shelf
Q
Other
Total No.
NIL
182NIL
5682365Due in 09-10
NIL
--
NIL
--
--
Replaced till date
NIL
--
NIL
--
--
Balance
NIL
--
NIL
--
--
14.SI-4 Position 01 yearAnnexure attached
Gears overdue for maintenance with SI-4 during last 06 months
15.Implantation of SignalAnnexure attached
16.Painting Details
17.
Earth testing detailsDescription
DG 1
DG 2
I/D Cable
O/D Cable
DOT
15.09.1115.09.1115.09.1115.09.11R-PhaseY-Phase
B-Phase
Neutral
5.3ohms
5.7ohms
6.1ohms
6.2ohms7.5ohms
5.3ohms
6.1ohms
6.0ohms6.1ohms
4.8ohms
Due on
Sept-12Sept-12Sept-12Sept-12
18.
No load currents position
Below 20 maAll Signals in RRI. Yard is LED Signal
Above 20 ma--
19.Staff StrengthAnnexure attached
SSE/SE/JE
MCM/ESM
MCM/MSM
Helper position
Vacant position
20.Railway Qr. PositionAnnexure attached
Type I
Type II
Type III & IV
Total Staff Housed/Un housed
21.Training position
Over due refresher course if any
NIL
CNB
22.Block Working position
With Track circuitTwin Single Line Panel with Continuous T/Circuit CPB Side
S/Line-D/Line workingDouble Line with Continuous T/Circuit GMC side & Semi Automatic Signalling CNBI Side
23.Power Supply Position
Total Battery SetDescription
12V
24V
60V
110V
Internal
--0101--External
02020101Others
--0101--Total
02040301
Total Track Battery
IPS Position--
24.DG Set Position DG Set- 1 DG Set-2
Make SUDHIR Cummins SUDHIR Cummins
Capacity125KVA 125 KVA
DOI20.03.2009 20.03.2009
Auto Start PositionYes Yes
Any other position-- ---
25.Cable Position
Total Cable2343 Nos.
Main Cable1523 Nos.
Tail Cable820 Nos.
STATION MIRROR RECORD (SIGNAL) OF BPU STATION-2010
S.No.ItemsDescription
1.Name of StationBPU
2.ClassSpl Class
3.Up & Dn./Line Position (with common loop position) -Description
Line No.
Dn. Loop Line
01
Dn. Main Line
02
Up Main Line
03
Up Loop Line
04
Common Loop Line
Nil
Others Line
Nil
Type of SignallingColour Light Signal
Panel InterlockingSolid State Interlocking
Auto Route SettingYes
Route Relay
Interlocking--
Hybrid Signalling--
Mechanical SignallingNil
4.Type of InterlockingStandard III Interlocking
Central Panel/End Panel/CabinCentral Panel
Type of PanelLCP
MakeSAMSUNG -214T
Date of Installation19.12.2007
5.Indication Position LED/LampLED Type
6.Track CircuitsDC Type
Total nos. of
Track circuits24
Type of G/Joints, RDSO JointsDescription
60Kg.
52 Kg.
90R
Total
G/Joints
68
06
Nil
74
RDSO Joints
Nil
Nil
02
02
7 .L-Xing Gate PositionDescription
Interlocked
85B 86B
Interlocked with
BPU- Stn. BPU- Stn.
Communication
BPU Stn. BPU-Stn.
Location
Km1038/13 -15 Km 1040/9 -11
8.SM Slide Frame
PositionDescription
Position
Type
Nil
Make
Nil
Total/Working
Nil
DOI
Nil
DOH
Nil
DOT
Nil
9.SI-26 Position (Signal Failure) 03 Years Comparative/01 Year Branch wise/Cause wiseAnnexure attached
BPU
10.Joint Pt. & Xing insp. Annexure attached
01 Year position with date & pending items
11.Accidents Position
On S&T AccountNIL
On Other branchNIL
12.B/Instt. PositionDescription
E/C
W/C
Connected with
Nil
Nil
Type
Nil
Nil
S.No.
Nil
Nil
DOH
Nil
Nil
DOI
Nil
Nil
Due O/H
Nil
Nil
13.Relay Position
(Periodicity of O/H of Relays)
Track 10 Yrs. ] As per
Line 12 Yrs. ] Div.
TR 12 Yrs. ] As per
Line 15 Yrs.] SEM IIDescription
Track Relay
Line Relay
Type
Shelf
Q
Shelf
Q
Other
Total No.
Nil
24
Nil
258
04Due in 06-07
Nil
--
Nil
--
Nil
Replaced till date
Nil
--
Nil
--
Nil
Balance
Nil
--
Nil
--
Nil
14.SI-4 Position 01 yearAnnexure attached
Gears overdue for maintenance with SI-4 during last 06 months
15.Implantation of SignalAnnexure attached
16.Painting Details2008-09
17.
Earth testing details
Description
B/Instt.
E/C
B/Instt.
W/C
LF
Cable
DOT
--
--
--
05.05.2009
Resistance
--
--
--
7.0 ohms
Due on
--
--
--
04.05.2010
18.
No load currents position
Below 20 maAll Signals
Above 20 maNIL
19.Staff Posted
SSE/SE/JE--
MCM/ESM02
MCM/MSM--
F/Gang position--
Helper position02
Vacant position02
20.Training position
Over due ref. course Not due
21.Block Working position
With Track circuitAutomatic Block system with Track Circuits and
With B/Instt--
With Axle counterWith Axle counter
S/Line-D/Line workingDouble line Automatic Block working
BPU
22.Power Supply Position Up and Dn. AT with 110V DC-IPS
Total Battery SetDescription
12V
24V
60V
110V
Internal
--
--
--
01
External
--
--
--
--
Others
--
--
--
--
Total
--
--
--
01
Total Track Battery72 Nos.
IPS Position110V DC-IPS STATECON MAKE
23.Cable Position
Total Cable 582 Nos.
Main Cable 263 Nos.
Tail Cable 319 Nos.
STATION MIRROR RECORD (SIGNAL) OF PNK STATION-2010
S.No.ItemsDescription
1.Name of StationPNK
2.ClassB Class
3.Up & Dn./Line Position (with common loop position) -Description
Line No.
Dn. Loop Line
--
Dn. Main Line
02
Up Main Line
03
Up Loop Line
04
Common Loop Line
01
Others Line
05 to 11 Goods Line
Type of SignallingElectro Mechanical with Colour Light Signal
Panel Interlocking--
Auto Route Setting--
Route Relay
Interlocking--
Hybrid SignallingYES
Mechanical SignallingHybrid Mechanical Signalling
4.Type of InterlockingStandard III Interlocking
Central Panel/End Panel/CabinCabin L/F
Type of Panel--
Make--
Date of Installation--
5.Indication Position LED/LampLED Type
6.Track CircuitsDC Single Rail Track Circuit
Total nos. of
Track circuits49 Nos.
Type of G/Joints, RDSO JointsDescription
60Kg.
52 Kg.
90R
Total
G/Joint
130
21
--
151
RDSO/Joint
40
01
07
48
7 .L-Xing Gate PositionDescription
Interlocked
Non-interlocked
81C, 82C
--
Interlocked with
E/C WOC
--
Communication
E/C WOC
--
Location
1028/13-15- 1029/35- 1028/14-16 1030/01
--
8.SM Slide Frame
PositionDescription
Position
Type
Modified
Make
PTJ
Total/Working
36/30 ( 06 spare)
DOI
Jan-2003
DOH
11.03.2008
DOT
07.04.2009
9.SI-26 Position (Signal Failure) 03 Years Comparative/01 Year Branch wise/Cause wiseAnnexure attached
PNK
10.New Work if any
Sanction work details--
Work in progressGMC PNK Automatic Block Signalling work in progress
Work recently done--
11.Joint Pt. & Xing inspection Annexure attached
01 Year position with date & pending items
12.Accidents Position
On S&T AccountNIL
On Other branchNIL
13.Lever Frame PositionDescription
E/C
W/C
WOC
WYC
Type/LF
Catch
Catch
Direct
Direct
T/Spare
86/04
80/13
35/01
24/05
DOH
DOT
14.B/Instt. PositionDescription
E/C
WOC
Connected with
Nil
Nil
Type
Nil
Nil
S.No.
Nil
Nil
DOH
Nil
Nil
DOI
Nil
Nil
Due O/H
Nil
Nil
15.Relay Position
(Periodicity of O/H of Relays)
Track 10 Yrs. ] As per
Line 12 Yrs. ] Div.
TR 12 Yrs. ] As per
Line 15 Yrs.] SEM IIDescription
Track Relay
Line Relay
Type
Shelf
Q
Shelf
Q
Other
Total No.
41
08
419
143
Nil
Due in 09-10
Replaced till date
Balance
Nil
--
Nil
--
Nil
16.SI-4 Position 01 yearAnnexure attached
Gears overdue for maintenance with SI-4 during last 06 months
17.Implantation of SignalAnnexure attached
18.Painting DetailsDec-2009
19.
Earth testing detailsDescription
WOC
W/C
WYC
E/C
DOT
17.05.09
17.05.09
20.05.09
20.05.09
Resistance
7.2 ohms
6.8 ohms
7.0 ohms
6.6 ohms
Due on
16.05.10
16.05.10
19.05.10
19.05.10
20.
No load currents position
Below 20 maAll Signals below 20 ma
Above 20 maNIL
21.Staff Posted
SSE/SE/JE01
MCM/ESM04
MCM/MSM04
F/Gang position--
Helper position09
Vacant position--
PNK
22.Training position
Over due refresher course if anyNil
23.Block Working position
With Track circuitAutomatic block signaling between PNK-BPU
With B/Instt
With Axle counterWith Axle Counter block working between PNK-GMC Side
S/Line-D/Line workingTwin Single Automatic block sig. between PNK-GMC Side
24.Power Supply Position
Total Battery SetDescription
12V
24V
60V
110V
Internal
05
03
--
03
External
07
--
--
--
Others
--
--
--
--
Total
12
03
--
03
Total Track Battery98 Nos.
IPS Position110V DC STATECON MAKE
25.Cable Position
Total Cable411 Nos.
Main Cable192 Nos.
Tail Cable219 Nos.
STATION MIRROR RECORD (SIGNAL) OF Holding Line GMC STATION
2010
S.No.ItemsDescription
1.Name of StationHolding Line GMC
2.ClassB Class
3.Up & Dn./Line Position (with common loop position) -Description
Line No.
Dn. Loop Line
01
Dn. Main Line
02
Up Main Line
03
Up Loop Line
--
Common Loop Line
--
Others Line
--
Type of SignallingColour Light Signal
Panel Interlocking--
Auto Route Setting--
Route Relay
InterlockingRoute Relay Interlocking (British)
Hybrid Signalling--
Mechanical Signalling--
4.Type of InterlockingStandard III Interlocking
Central Panel/End Panel/CabinCentral Panel operated with SM Slide Frame
Type of PanelConsole
Make--
Date of Installation03/01/1967 ( Modified 23.05.08)
5.Indication Position LED/LampLamp Type
6.Track CircuitsDC Single Rail Track Circuit
Total nos. of
Track circuits13 Nos.
Type of G/Joints, RDSO JointsDescription
60Kg.
52 Kg.
90R
Total
G/Joint
15
19
--
34
RDSO/Joint
--
05
--
05
7 .L-Xing Gate PositionDescription
Interlocked
Non-interlocked
G-240A
--
Interlocked with
Panel
--
Communication
ASM H/Line
--
Location
GMC-BZM
--
8.SM Slide Frame
PositionDescription
Position
Type
Modified Type
Make
PTJ
Total/Working
12/04 Nos.
DOI
29.02.1980
DOH
23.06.2008
DOT
30.11.2009
9.SI-26 Position (Sig Failure) 03 Years Comparative/01 Year Branch wise/Cause wiseAnnexure attached
H/L
10.New Work if any MERGER WITH GMC/SSI- WORK
Sanction work details--
Work in progressDoubling work between GMC to BZM is completed
Work recently doneAutomatic block Signalling GMC-PNK N/L & S/L
11.Joint Pt. & Xing inspection Annexure attached
01 Year position with date & pending items
12.Accidents Position
On S&T AccountNIL
On Other branchNIL
13.Lever Frame PositionDescription
G240-A
Type of LF
Direct Type
Total/Spare Nos. of levers
04/01
DOH
23.06.2008
DOT
30.11.2009
14.B/Instt. PositionDescription
JHS Side
Connected with
BZM
Type
S.No.
Maintained by JHS Division
DOH
DOI
Due O/H
15.Relay Position
(Periodicity of O/H of Relays)
Track 10 Yrs. ] As per
Line 12 Yrs. ] Div.
TR 12 Yrs. ] As per
Line 15 Yrs.] SEM IIDescription
Track Relay
Line Relay
Type
Shelf
Q
Shelf
Q
Other
Total No.
13
--
144
06
03
Due in 09-10
Nil
Nil
Nil
Nil
Nil
Replaced till date
--
--
--
--
--
Balance
--
--
--
--
--
16.SI-4 Position 01 yearAnnexure attached
Gears overdue for maintenance with SI-4 during last 06 monthsNIL
17.Implantation of SignalAnnexure attached
18.Painting DetailsApril 2009
19.
Earth testing detailsDescription
B/Instt.
E/C
B/Instt.
W/C
LF
Cable
DOT
--
--
--
30.05.2009
Resistance
--
--
--
8.3 Ohms
Due on
--
--
--
29.05.2010
20.
No load currents position
Below 20 maAll Signals
Above 20 maNIL
21.Staff Posted
SSE/SE/JE--
MCM/ESM01
MCM/MSM01
F/Gang position--
Helper position04
Vacant position--
H/L
22.Training position
Over due refresher course if anyNo Due of any staff
23.Block Working position
With Track circuitBetween RRI/GMC
With B/InsttBetween BZM
With Axle counter--
S/Line-D/Line working
24.Power Supply Position
Total Battery SetDescription
12V
24V
60V
110V
Internal
01
--
--
--
External
02
02
--
01
Others
--
--
--
--
Total
03
02
--
01
Total Track Battery
IPS Position
25.DG Set Position01
Make Kirloskar
CapacityBHP-6, KVA-3
DOI1978
Auto Start PositionManual operation
Any other position--
26.Cable Position
Total Cable119
Main Cable74
Tail Cable45
STATION MIRROR RECORD (SIGNAL) OF GMC/RRI STATION-2011
S.No.ItemsDescription
1.Name of StationGMC/RRI
2.ClassSpl Class
3.Up & Dn./Line Position (with common loop position) -Description
Line No.
Dn. Loop Line
--
Dn. Main Line
N/Line wkg. As twin single line
Up Main Line
S/Line wkg. As twin single line
Up Loop Line
--
Common Loop Line
02 to 16 lines common goods line
Others Line
Type of SignallingMulti Aspect Colour Light Signal
Panel Interlocking--
Auto Route SettingYES
Route Relay
InterlockingRoute Relay Interlocking (Siemens), Auto Route Setting Type
Hybrid Signalling--
Mechanical Signalling--
4.Type of InterlockingStandard III Interlocking
Central Panel/End Panel/CabinCentral Panel
Type of PanelSiemens Domino Type
MakeSiemens
Date of Installation27/02/1978
5.Indication Position LED/LampLamp Type
6.Track CircuitsDC Single Rail Track Circuit
Total nos. of
Track circuits167 Nos.
Type of G/Joints, RDSO JointsDescription
60Kg.
52 Kg.
90R
Total
G/Joint
211
156
--
367
RDSO/Joint
4215367
262
7.SI-26 Position (Signal Failure) 03 Years Comparative/01 Year Branch wise/Cause wiseAnnexure attached
8.New Work if anyGMC-SSI work in progress
Sanction work details--
Work in progress--
Work recently doneAutomatic Signalling in N/L & S/L GMC-PNK in 2010
9.Joint Pt. & Xing inspection Annexure attached
pending items. attached
01 Year position with date & pending items
10.Accidents Position
On S&T AccountNIL
On Other branchLoco (Mech.)
GMC
11.Relay PositionDescription
Track Relay
Line Relay
Type
Shelf
Q
Shelf
Q
Other
Total No.
371521692163423
Due in 09-10
----------Replaced till date
Balance
Nil
Nil
Nil
Nil
Nil
12.SI-4 Position 01 yearAnnexure attached
Due gears from last
06 months
13.Implantation of SignalAnnexure attached
14.Painting DetailsDec -2010
15.
Earth testing detailsDescription
DG 1
DG 2
I/D Cable
O/D Cable
DOT
16.05.10
16.05.10
16.05.10
16.05.10
Resistance
5.4 Ohms
5.0 Ohms
5.1 Ohms
5.3 Ohms
Due on
May-11
May-11
May-11
May-11
16.
No load currents position
Below 15 maLED Aspect provided
Above 15 ma--
17.Staff StrengthAnnexure attached
SSE/SE/JE
MCM/ESM
MCM/MSM
F/Gang position
Helper position
Vacant position
18.Railway Qr. PositionAnnexure attached
Type I
Type II
Type III & IV
Total Staff Housed/Un housed
19.Training position
Over due refresher course if anyNIL
20.
Block Working position
With Track circuitContinuous T/Circuit in CNB Side Twin Single Line wkg.
With B/Instt--
With Track circuitPNK Side Twin Single Line wkg. With Automatic block Sig.
S/Line-D/Line workingTwin Single Line in N/L & S/L Automatic block working between C-Panel & PNK in 3rd & 4th line & GMC-PNK
21.Power Supply Position
Total Battery SetDescription
12V
24V
60V
110V
Internal
--
--
01
--
External
--
03
01
01
Others
--
02
01
01
Total
--
05
03
02
Total Track Battery456 Nos.
IPS Position--
GMC
22.DG Set PositionDG Set 1 DG Set 2
Make Kirloskar Ruston
Capacity34KVA 43.0KVA
DOI27/02/1978 25/06/1993
Auto Start PositionYES YES
Any other position-- --
23.Cable Position
Total Cable1197 Nos.
Main Cable468 Nos.
Tail Cable729 Nos.
STATION MIRROR RECORD (SIGNAL) OF A Cabin/GMC
S.No.ItemsDescription
1.Name of StationA Cabin/GMC
2.ClassSpl Class
3.Up & Dn./Line Position (with common loop position) -Description
Line No.
Dn. Loop Line
--
Dn. Main Line
--
Up Main Line
--
Up Loop Line
--
Common Loop Line
L/No. 17 to 34 Goods Line
Others Line
--
Type of SignallingMechanical
Panel Interlocking--
Auto Route Setting--
Route Relay
Interlocking--
Hybrid Signalling--
Mechanical SignallingYES
4.Type of InterlockingStandard III Interlocking, LQ
Central Panel/End Panel/Cabin--
Type of Panel--
Make--
Date of Installation--
5.Indication Position LED/Lamp--
6.Track Circuits
Total nos. of
Track circuits--
Type of G/Joints, RDSO Joints--
7 .L-Xing Gate Position--
8.SI-26 Position (Sig Failure) 03 Years Comparative/01 Year Branch wise/Cause wiseAnnexure attached
9.New Work if any3rd & 4th Line work completed by IRPMU
Sanction work details--
Work in progressYES
Work recently done--
10.Joint Pt. & Xing inspection Annexure attached
pending items. attached
01 Year position with date & pending items
11.Accidents Position
On S&T AccountNIL
On Other branchNIL
12.Lever Frame PositionDescription
A Cabin
Type of LF
Direct Type
Total/Spare Nos. of levers
56/NIL
DOH
05/12/2011DOT
05/12/2011
13.Relay PositionDescription
Track Relay
Line Relay
Type
Shelf
Q
Shelf
Q
Other
Total No.
--
--
18
--
--
Due in 06-07
--
--
--
--
--
Replaced till date
--
--
--
--
--
Balance
--
--
--
--
--
14.SI-4 Position 01 yearAnnexure attached
Due gears from last
06 months
15.Implantation of SignalAnnexure attached
16.Painting DetailsApril 2011
17.
Earth testing detailsDescription
Cable
L/Frame
DOT
17/05/1117/05/11Resistance
5.3 ohm
6.8 ohm
Due on
May 2012May 2012
18.
No load currents position
Below 20 ma--
Above 20 ma--
19.Staff Posted
SSE/SE/JE--
MCM/ESM--
MCM/MSM01
F/Gang position--
Helper position02
Vacant position--
20.Training position
Over due ref. courseNIL
22.Block Wkg position
With Track circuit--
With B/Instt--
With Axle counter--
SL/DLine workingAbsolute block working
23.Power Supply Position
Total Battery SetDescription
12V
24V
60V
110V
Internal
01
--
--
--
External
01
--
--
--
Others
--
--
--
--
Total
02
--
--
--
Total Track Battery--
IPS Position--
24.Cable Position
Total Cable55 Nos.
Main Cable40 Nos.
Tail Cable15 Nos.
STATION MIRROR RECORD (SIGNAL) OF B Cabin/GMC
S.No.ItemsDescription
1.Name of StationB Cabin/GMC
2.ClassSpl Class
3.Up & Dn./Line Position (with common loop position) -Description
Line No.
Dn. Loop Line
--
Dn. Main Line
--
Up Main Line
--
Up Loop Line
--
Common Loop Line
L/No. 17 to 34 Goods Line
Others Line
--
Type of SignallingMechanical, Type SA - 1101
Panel Interlocking--
Auto Route Setting--
Route Relay
Interlocking--
Hybrid Signalling--
Mechanical SignallingYES
4.Type of InterlockingStandard III Interlocking, LQ
Central Panel/End Panel/Cabin--
Type of Panel--
Make--
Date of Installation--
5.Indication Position LED/Lamp--
6.Track Circuits
Total nos. of
Track circuits--
Type of G/Joints, RDSO Joints--
7 .L-Xing Gate Position--
8.SI-26 Position (Sig Failure) 03 Years Comparative/01 Year Branch wise/Cause wiseAnnexure attached
9.New Work if any3rd & 4th Line work completed by IRPMU
Sanction work details--
Work in progressYES
Work recently done--
10.Joint Pt. & Xing inspection Annexure attached
pending items. attached
01 Year position with date & pending items
11.Accidents Position
On S&T AccountNIL
On Other branchNIL
12.Lever Frame PositionDescription
A Cabin
Type of LF
Catch Type SA 1101
Total/Spare Nos. of levers
100/NIL
DOH
DOT
15/12/2011
13.Relay PositionDescription
Track Relay
Line Relay
Type
Shelf
Q
Shelf
Q
Other
Total No.
--
--
14
--
--
Due --
--
----
--
Replaced till date
--
--
14--
--
Balance
--
--
----
--
14.SI-4 Position 01 yearAnnexure attached
Due gears from last
06 months
15.Implantation of SignalAnnexure attached
16.Painting DetailsApril 2011
17.
Earth testing detailsDescription
Cable
L/Frame
DOT
20/05/1120/05/11Resistance
5.3 ohm
6.8 ohm
Due on
May 2012May 2012
18.
No load currents position--
Below 20 ma--
Above 20 ma--
19.Staff Posted
SSE/SE/JE01
MCM/ESM--
MCM/MSM01
F/Gang position01
Helper position02
Vacant position04
20.Training position
Over due ref. courseNIL
21.Block Wkg position
With Track circuit--
With B/Instt--
With Axle counter--
SL/DLine workingAbsolute block working
22.Power Supply Position
Total Battery SetDescription
12V
24V
60V
110V
Internal
01
--
--
--
External
01
--
--
--
Others
--
--
--
--
Total
02
--
--
--
Total Track Battery--
IPS Position--
23.Cable Position
Total Cable55 Nos.
Main Cable40 Nos.
Tail Cable15 Nos.