state of virginia’s adoption uniform statewide building code –adopts model codes by reference...

13
State of Virginia’s State of Virginia’s Adoption Adoption Uniform Statewide Building Code Adopts model codes by reference Family of I Codes 2003 edition NEC 2002 edition Statewide adoption of amendments Uniform across State May not be amended by City or County Adoption date: November 16, 2005 Mandatory enforcement after November 16, 2006.

Upload: alfred-eaton

Post on 16-Dec-2015

221 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: State of Virginia’s Adoption Uniform Statewide Building Code –Adopts model codes by reference Family of I Codes 2003 edition NEC 2002 edition –Statewide

State of Virginia’s AdoptionState of Virginia’s Adoption

Uniform Statewide Building Code– Adopts model codes by reference

• Family of I Codes 2003 edition• NEC 2002 edition

– Statewide adoption of amendments– Uniform across State– May not be amended by City or County

Adoption date: November 16, 2005 Mandatory enforcement after

November 16, 2006.

Page 2: State of Virginia’s Adoption Uniform Statewide Building Code –Adopts model codes by reference Family of I Codes 2003 edition NEC 2002 edition –Statewide

What Codes are adopted?What Codes are adopted?

Building Code (IBC 2003) Mechanical Code (IMC 2003) Plumbing Code (IPC 2003) Fuel Gas Code (IFGC 2003) Electric Code (NEC2002) Dwelling Code (IRC 2003) Energy Code (IECC 2003) Accessibility (ANSI 117-03) Virginia Rehabilitation Code (IEBC 2003) Virginia Maintenance Code (IPMC 2003) Virginia Construction Code (USBC2005)

Page 3: State of Virginia’s Adoption Uniform Statewide Building Code –Adopts model codes by reference Family of I Codes 2003 edition NEC 2002 edition –Statewide

DescriptionDescription I Codes are a family of Codes Integrated - with inter-related code

provisions linked together Developed by City, County and State

building safety professionals with significant input from the design community and the construction industry.

Industry membership (Including HBAV) on code committees establishes a consensus-based code development process.

FOR MORE INFO...

www.iccsafe.org

(800) 786-4452

Page 4: State of Virginia’s Adoption Uniform Statewide Building Code –Adopts model codes by reference Family of I Codes 2003 edition NEC 2002 edition –Statewide

Significant Changes in IRC 2003Significant Changes in IRC 2003 Table R301.5 allows for attic without storage live load of 10psf. R302 Location on lot: USBC 5’ or 1 hour rating; 3’-5’ only 25% of

wall permitted to have openings. Section R303.2 allows a Sunroom to provide light to interior room. Section R303.4 sets location requirements of intake and exhaust

openings. R305.1 Ceiling height for bathrooms is clarified: 6’8” over fixtures. R308.4 item #9: Safety glazing is required for stair landings within

36” horizontally and 60 inches vertically of floor. R309.2 Garage separation from habitable areas with ½inch drywall

on walls and 5/8 inch in floor ceiling separations. Adjacent walls supporting this must be ½ inch drywall.

Page 5: State of Virginia’s Adoption Uniform Statewide Building Code –Adopts model codes by reference Family of I Codes 2003 edition NEC 2002 edition –Statewide

Significant Changes in IRC 2003Significant Changes in IRC 2003 R309.6 Automatic garage door openers must meet UL325. R310.1 Egress window requirements in basements are

clarified. R311.5.6 Handrails required with four risers (previously

three). R311.4.1 Access to other habitable levels must be by ramp

or stair. R311.5.6.2 Handrails must be continuous for flight…

terminate in newels R311.5.6.3 Handrail grip size clarified R312.1 Porches and decks with insect screening must have

guards. R314.2 Stair riser and depth requirements remain the same:

8 ¼ inch rise; 9 inch minimum tread.

Page 6: State of Virginia’s Adoption Uniform Statewide Building Code –Adopts model codes by reference Family of I Codes 2003 edition NEC 2002 edition –Statewide

Significant Changes in 2003 IRCSignificant Changes in 2003 IRC R317.2 Town home separation must include attached

accessory structures. R323 Flood resistant requirements requires protection for

mechanical and electrical systems including ductwork. As-Built drawings are now required.

Section 402.3 permits pre-cast concrete foundations Table R403.1 Minimum footing widths decreased. R404.1.5.1 Pier and curtain wall foundations systems are

limited to two stories (without a design). Section R408.3 requires under-floor access to be 16” by 24”

in wall; 18” by 24” in floor. Section R502.2.1 Provides a table for bolt size and spacing

for deck support. Table R502.3.3(1) establishes cantilever limits for floor joists.

(NEW).

Page 7: State of Virginia’s Adoption Uniform Statewide Building Code –Adopts model codes by reference Family of I Codes 2003 edition NEC 2002 edition –Statewide

Significant Changes in 2003 IRCSignificant Changes in 2003 IRC Section R502.4 Joists under bearing partitions must be sized for

the load imposed (Double joists may not be enough-Beam may be needed).

Table R602.3(5) Size, height and spacing of wood studs is limited to two floors and roof.

R602.6.1 Limits drilling or notching of top plate to 50% of width. R602.6.1 requires 8 nails per side of strap when top plate is cut,

drilled or notched over 50% of width. R702.4.2 prohibits water resistant Gypsum backer board over

vapor retarder in tub/shower compartment. R905.2.6 requires special fastening methods for high wind speeds

(ASTM 3161). Section R1001.6.1 Establishes requirements for spark arrestors.

Page 8: State of Virginia’s Adoption Uniform Statewide Building Code –Adopts model codes by reference Family of I Codes 2003 edition NEC 2002 edition –Statewide

HOT TOPICSHOT TOPICS

R311.4.3 as amended: Landings at doors: There shall be a floor or landing on each side of each exterior door. The width of each landing shall not be less than the door served. Every landing shall have a minimum dimension of 36 inches measured in the direction of travel. EXCEPTION: Where a stairway of 2 or fewer risers is located on the exterior side of a door, other than the required exit door, a landing is not required for the exterior side of the door. NOTE: The 2006 IRC does not include stairs in an enclosed garage provided a door does not swing over the stairs.

Page 9: State of Virginia’s Adoption Uniform Statewide Building Code –Adopts model codes by reference Family of I Codes 2003 edition NEC 2002 edition –Statewide

HOT TOPICSHOT TOPICS

R319 – Protection against decayR319.3 – Fasteners – Fasteners for

pressure preservative and fire-retardant-treated wood shall be of hot-dipped galvanized steel, stainless steel, silicone bronze or copper.

Page 10: State of Virginia’s Adoption Uniform Statewide Building Code –Adopts model codes by reference Family of I Codes 2003 edition NEC 2002 edition –Statewide

HOT TOPICSHOT TOPICS

M1601.3.1 – Duct Systems Joints and Seams Joints of duct systems shall be made substantially airtight by means of tapes, mastics, gasketing, or other approved closure systems.

Use UL 181A for rigid fibrous ductsUse UL 181B for flexible air ducts

and connectors

Page 11: State of Virginia’s Adoption Uniform Statewide Building Code –Adopts model codes by reference Family of I Codes 2003 edition NEC 2002 edition –Statewide

Common Code ProblemsCommon Code Problems Shear walls and wall bracing not being installed properly. Flood Vents not being installed; using foundation vents instead… Footings improperly dug; soil not solid. Foundation piers over 4X the height (32” for 8”) not filled. Box connection to girder missing or improper. Exterior nailing improper (6” and 12”) Excessive cutting/notching of structural members. Fireblocking missing or improperly installed. Flashing not being installed properly Pier and Curtain Wall Foundation design limited to two floors and a roof, not three

floors and roof w/o design. Guards installed with improper height, intermediate picket spacing or strength. Handrails: Improper height, size of railing. Elevation certificate for BFE missing (As-built survey) Window labeling for energy code or safety glazing. Residential elevators Deck construction (Section R502.2.1) Permits for re-roofing (Required in high wind speeds)

Page 12: State of Virginia’s Adoption Uniform Statewide Building Code –Adopts model codes by reference Family of I Codes 2003 edition NEC 2002 edition –Statewide

What’s next?What’s next?

2006 IRC is available now.State and VBCOA have begun

working on adoption for next cycle. Your input for State Amendments are encouraged.

Page 13: State of Virginia’s Adoption Uniform Statewide Building Code –Adopts model codes by reference Family of I Codes 2003 edition NEC 2002 edition –Statewide

QUESTIONSQUESTIONS