stardiagnosis_hms990
DESCRIPTION
automotive scan toolsTRANSCRIPT
Measurement Technology HMS 990 USB Brochure
Reinforcement for Star Diagnosis compact 4 HMS 990 USB Measurement Technology is the ideal enhancement for the diagnosis capabilities of Star Diagnosis compact4. The combination of these two powerful devices allows service technicians to thoroughly check a vehicle in every detail. HMS 990 USB Measurement Technology can be used immediately on Star Diagnosis compact4 without any additional hardware installation. One great advantage is the direct link between the diagnosis applications Xentry Diagnostics (from model series 204) and DAS and the Measurement Technology software. If required, the universal oscilloscope can be called up directly from the diagnosis test procedure. Here, the measurement channel parameters are preset and a pass image is displayed. Extensive measuring options – The electrical system Service technicians can carry out a wide range of measurements on the vehicle’s electrical system. Various voltages, ignition and dwell angles – all the essential values can checked. The equipment can even be used to check whether all the alternator values are OK. The multimeter provides the opportunity to accurately check the basic electrical parameters such as voltage, current, resistance, frequency, temperature, and pressure. With this range of capabilities, the service technician always has a grip on that most sensitive vehicle component – the electrical system. Thorough examination The ignition rating must always be adjusted perfectly for the engine to give its best performance. HMS 990 USB Measurement Technology offers the service technician many means for checking the ignition ratings and to indicate variances. Service technicians can thus take the results of measurements as their basis for assessing whether the data displayed is OK, or whether it has to be corrected.
Are things running smoothly ? -- Analysis of individual cylinders Is the engine running as it should ? HMS 990 USB Measurement Technology makes it possible to check the duration of combustion by analyzing individual cylinders. Compression and rotational speed are also always in check. The service technician is immediately notified of deviations from the specified values.
Signal measurements with oscilloscopes Service technicians use the universal oscilloscope and the 12-channel oscilloscope to measure various signals such as those from the crankshaft position sensor or the camshaft Hall sensor. Recording can extend over several minutes. The service technician can store the measurements taken with the recorder function and retrieve them at a later point. HMS 990 USB Measurement Technology also offers numerous possibilities for the evalulation of the values measured. Product Information Applications This equipment has been exclusively designed for the Star Diagnosis compact4. It cannot be connected to the Star Diagnosis basic2. • Multimeter function • Universal, 12-channel and ignition oscilloscope • Engine test • Sensor input
Components • The portable HMS 990 USB Measurement Technology is supplied as a stand-along device. The
housing is protected by a sturdy rubber jacket. The device is operated via a USB 2.0 interface. • Power supply unit with country-specific connector cable • Battery cable set • Measurement Technology cable set • HMS 990 USB activation CD • HMS 990 USB user guide
Connections
• Voltage, resistance, diode and frequency measurements
• Ground • Current measurements; direct 1
amp; electronically fused. Fuse is automatically activated after a failure
• Connections for both universal and 12-channel oscilloscopes
• Sensor interface for general engine test functions
Contract term • Contract term and support services are always bound
to those of the associated Star Diagnosis compact4 system
Languages
• The HMS 990 USB interface is available in all Star Diagnosis system languages.
Permanent help and support
• The Star Diagnosis User Help Desk gives advice on the software and hardware
• Competent advice in the following languages: German, English, French, Spanish, Italian and Japanese
Mercedes-Benz Canada May 2010
Daimler AG
GSP/OI
D-70546 Stuttgart
Measurement Technology HMS 990 USB
Software Release 5.0.0
Page 1 of 3
New functionalities in the Measurement Technology
Software-Release 5.0.0
Overview
To meet the current requirements on vehicle diagnosis, additional functionalities have been added to the software for the HMS
990 USB measurement technology. These innovations enable the service personnel to an easier assessment of complex signals
and the technical hotline is given better possibilities to support and solve problems.
All the new functionalities will be explained to the user during the guided test. No special training is therefore necessary.
The software release 5.0.0 is available in the markets since Star Diagnosis Update 11/09.
New functionalities:
Signal measurement .......................................................................................................................................................................1 Storage of series of measurements................................................................................................................................................1 Storage of images...........................................................................................................................................................................2 Current clamps measuring range ...................................................................................................................................................2 Measurement of the start of delivery .............................................................................................................................................3
Signal measurement
With the new software release, amplitudes and
times can be measured directly including
automatic conversion to frequency. In addition,
all signals can be analyzed with a freely
selectable reference base (100%, 360°, 720°).
Storage of series of measurements
This functionality enables the service personnel
to save, archive and reload complete series of
measurements. This means that in the event of
an error, the technical hotline can assess the
situation more easily and provide better
support.
Delta measurement
channel A Y2 – Y1
channel B Y2 – Y1
active cursor
Measuring range
Signal measurement
Daimler AG
GSP/OI
D-70546 Stuttgart
Measurement Technology HMS 990 USB
Software Release 5.0.0
Page 2 of 3
Storage of images
Individual images can now be stored directly as
a bmp or gif image file.
Current clamps measuring range
New measuring ranges (10 mV/A, KR 015,
100mV/A) have been included for current
clamps.
Display settings
window size
start maximized
enlargeable
adjust size
Control key F4
output target
standard printer
File parameters Target Directory
basic file name running number
Measuring range Measurement signal
voltage
current
resistance
frequency
temperature
pressure
diode test
Daimler AG
GSP/OI
D-70546 Stuttgart
Measurement Technology HMS 990 USB
Software Release 5.0.0
Page 3 of 3
Measurement of the start of delivery
The measurement of the start of delivery
according to the governor impulse method can
now be applied in full thanks to a new method
using the existing adapter.