stak-file01stratus 5 metalcraft roofing01 wip01 bim© 2013...

22
www.metalcraftgroup.co.nz Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: [email protected] Thermopanel EPS TPWD EXTERNAL WALL DETAILS Metalcraft Insulated Panel Systems 00 / 21 COVER SHEET 01 / 21 PARAPET 02 / 21 WINDOW HEAD 03 / 21 WINDOW SILL AND JAMB 04 / 21 VERTICAL JOINT TYPE C 05 / 21 PIPE PENETRATION w DEKTITE FLASHING 06 / 21 PIPE PENETRATION w PVC FLANGE 07 / 21 MIDFLOOR JOINT 08 / 21 SECRET FIXING JOINT 01 09 / 21 SECRET FIXING JOINT 02 10 / 21 METERBOX JAMB HEAD AND SILL DETAIL 11 / 21 INTERNAL/EXTERNAL CORNER DETAIL 12 / 21 ALTERNATIVE INTERNAL CORNER 13 / 21 ALTERNATE EXTERNAL CORNER 14 / 21 ABUTMENT 01 15 / 21 ABUTMENT 02 16 / 21 BOTTOM OF CLADDING 01 17 / 21 BOTTOM OF CLADDING 02 18 / 21 BOTTOM OF CLADDING 03 19 / 21 BOTTOM OF CLADDING 04 20 / 21 BOTTOM OF CLADDING 05 21 / 21 PANEL PROFILE AND SIZE DETAIL LIST

Upload: trantu

Post on 26-Jul-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

www.metalcraftgroup.co.nz

Architectural / Specification EnquiriesPh: 09 274 0408

Mobile: 027 603 1096Email: [email protected]

Thermopanel EPS

TPWD

EXTERNAL WALL DETAILS

MetalcraftInsulated Panel Systems

00 / 21 COVER SHEET01 / 21 PARAPET02 / 21 WINDOW HEAD03 / 21 WINDOW SILL AND JAMB04 / 21 VERTICAL JOINT TYPE C05 / 21 PIPE PENETRATION w DEKTITE FLASHING06 / 21 PIPE PENETRATION w PVC FLANGE07 / 21 MIDFLOOR JOINT08 / 21 SECRET FIXING JOINT 0109 / 21 SECRET FIXING JOINT 0210 / 21 METERBOX JAMB HEAD AND SILL DETAIL11 / 21 INTERNAL/EXTERNAL CORNER DETAIL12 / 21 ALTERNATIVE INTERNAL CORNER13 / 21 ALTERNATE EXTERNAL CORNER14 / 21 ABUTMENT 0115 / 21 ABUTMENT 0216 / 21 BOTTOM OF CLADDING 0117 / 21 BOTTOM OF CLADDING 0218 / 21 BOTTOM OF CLADDING 0319 / 21 BOTTOM OF CLADDING 0420 / 21 BOTTOM OF CLADDING 0521 / 21 PANEL PROFILE AND SIZE

DETAIL LIST

Page 2: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

EPS PACKER

PRE-FINISHED SCREWWITH RUBBER WASHER

METALCRAFTTHERMOPANEL

STRUCTURE BY OTHERS

PRE-FINISHED PARAPET CAPFLASHING NO FIXINGS ON TOPOF FLASHING

ø5mm RIVETS @ 300mm CRS

5.00

°

VAPOUR RESISTANT MASTIC SEALANT

200m

m M

IN.

200m

m M

IN.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

PARAPET

01 / 2130.08.2016

Page 3: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFTTHERMOPANEL

TEMPORARY PACKER IF REQUIRED,REMOVED AFTER FIXING

PRE-FINISHED WINDOW HEADFLASHING WITH 15° FALL

DOUBLE GLAZING WINDOW JOINERY

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILLAND JAMB

WINDOW HEAD LINER

LINE OF WINDOW JAMBLINER BEHIND

EXPANDALBE WATERTIGHTCOMPRIBAND TAPE

SILICON SEALANTØ5mm RIVETS @ 300mm CRS

SILICON SEALANT

ALUMINIUM JOINERY

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

WINDOW HEAD

02 / 2130.08.2016

Page 4: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

DOUBLE GLAZING WINDOW JOINERY

LINE OF WINDOW JAMB LINER BEHIND

WINDOW SILL LINER EXPANDALBE WATERTIGHTCOMPRIBAND TAPE

Ø5mm RIVETS @ 300mm CRS

ALUMINIUM JOINERY

METALCRAFTTHERMOPANEL

SILICON SEALANT

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

WINDOW SILL AND JAMB

03 / 2130.08.2016

Page 5: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFT THERMOPANEL

Ø5mm RIVETS @ 300mm CRS.

TOP-HAT SECTION. COLOURAS REQUIRED. (RIVETS ANDSEALANT UNDER EACH LEGOF TOP-HAT)

TIMBER

PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER

SEALANT

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

VERTICAL JOINT TYPE C

04 / 2130.08.2016

Page 6: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFTTHERMOPANEL WALL

DEKTITE PIPE FLASHING

Ø5mm RIVETS @ 300mm CRS

300mm Ø MAX. PIPE

0.55mm INTERNAL FLASHING OR PVCFLANGE

OUTSIDE INSIDE

SEALANT

ENSURE TIGHT FIT TO CORE MATERIAL,ALTERNATIVELY, USE EXPANDING FOAM

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

PIPE PENETRATION w DEKTITE FLASHING

05 / 2130.08.2016

Page 7: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFTTHERMOPANEL WALL

Ø5mm RIVETS @ 300mm CRS

300mm Ø MAX. PIPE

0.55mm INTERNAL FLASHING OR PVCFLANGE

OUTSIDE INSIDE

ENSURE TIGHT FIT TO CORE MATERIAL,ALTERNATIVELY, USE EXPANDING FOAM

SEALANT

SEALANT

SEALANT

0.55mm INTERNAL FLASHING OR PVCFLANGE

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

PIPE PENETRATION w PVC FLANGE

06 / 2130.08.2016

Page 8: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFT THERMOPANEL

Ø 6mm DRAINAGEHOLES @ 1000mm CTRS

ø5mm RIVETS @ 300mm CRS.

50m

m M

IN.

100m

m M

IN.

PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER

PRE-FINISHED FLASHING SLOTTEDBETWEEN PANEL ANDSECONDARY FLASHING

TIMBER

VAPOUR RESISTANT MASTIC SEALANT

0.55 SECONDARY FLASHING ORALUMINIUM ANGLE FIXED TOPANEL BEFORE INSTALMENT

PRE-FINISHED FLASHING WITH15° FALL

COMPRESSIBLE FOAM SEAL TO FILLOVERLAP OF FLASHING

099A PVC FOAM TAPE

VAPOUR RESISTANT MASTIC SEALANT

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

MIDFLOOR JOINT

07 / 2130.08.2016

Page 9: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFTTHERMOPANEL WALL

SECRET FIXINGS @ 300mm CRS.

VAPOUR RESISTANT MASTIC SEALANT

EXTERNAL

INTERNAL

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

SECRET FIXING JOINT 01

08 / 2130.08.2016

Page 10: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFTTHERMOPANEL

VAPOUR RESISTANTMASTIC SEALANT

EXTERNAL

INTERNAL

TIMBER

5mm ALUMINIUMANGLE CLEAT

ALUMINIUM BASECAP 300mm LONG MIN

ø5mm RIVETS

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

SECRET FIXING JOINT 02

09 / 2130.08.2016

Page 11: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFTTHERMOPANEL METERBOX

PVC SLEEVE FORCABLE ACCESS

ALUMINIUMANGLE

SEALANT

ø5mm RIVETS@ 300crs

PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

METERBOX JAMB HEAD AND SILL DETAIL

10 / 2130.08.2016

Page 12: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFT THERMOPANEL

Ø5mm RIVETS @ 300mm CRS.

40mm x 40mm 0.55mm MIN.FOLDED ALUMINIUMEXTERNAL ANGLE

40mm x 40mm 0.55mm MIN.FOLDED ALUMINIUM

INTERNAL ANGLE

Ø5mm RIVETS @ 300mm CRS

Ø5mm RIVETS @ 300mm CRS.WITH SEALANT

SEALANT

NOTE:ALUMINIUM ANGLES CAN BEREPLACED WITH STEEL

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

INTERNAL/EXTERNAL CORNER DETAIL

11 / 2130.08.2016

Page 13: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFTTHERMOPANEL

Ø5mm RIVETS @ 300mm CRS.

Ø5mm RIVETS @ 300mm CRS

VAPOUR RESISTANT MASTIC SEALANT

Ø40mm WASHER AND M10 ZPHEX NUT

TIMBER

0.55 SECONDARY FLASHING OR ALUMINUMANGLE

100m

m M

IN.

PRE-FINISHED FLASHING

40x40 ALUMINUM ANGLE

PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

ALTERNATIVE INTERNAL CORNER

12 / 2130.08.2016

Page 14: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFT THERMOPANEL

Ø5mm RIVETS @ 300mm CRS

VAPOUR RESISTANT MASTIC SEALANT

TIMBER

40 x 40 ALUMINIUM ANGLE ON SEALANT

170mm MIN.

PRE-FINISHED FLASHING

PRE-FINISHED SELFDRILLING/TAPPING SCREWWITH RUBBER WASHER

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

ALTERNATE EXTERNAL CORNER

13 / 2130.08.2016

Page 15: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFTTHERMOPANEL

Ø5mm RIVETS

VAPOUR RESISTANT MASTIC SEALANT

TIMBER

PAINTED CONCRETE BY OTHERS

70mm MIN.

PRE-FINISHED FLASHING

Ø6.5mm / 32 mm SHUREDRIVES @ 300mmCRS. OR AS SPECIFIED BY ENGINEER

ALUMINUM CHANNEL

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

VAPOUR RESISTANT MASTIC SEALANT

FOAM BACKING ROD

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

ABUTMENT 01

14 / 2130.08.2016

Page 16: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFT THERMOPANEL

Ø5mm RIVETS @ 300mm CRS

VAPOUR RESISTANT MASTIC SEALANT

STRUCTURE BY OTHERS

PAINTED CONCRETE BY OTHERS

Ø6.5mm / 32 mm SHUREDRIVES @ 300mmCRS. OR AS SPECIFIED BY ENGINEER

200mm

PRE-FINISHED FLASHING

FOAM BACKING ROD

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

ABUTMENT 02

15 / 2130.08.2016

Page 17: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFT THERMOPANEL WALL

ø6mm DRAINAGEHOLES @ 1000 CRS

ø5mm RIVETS @ 300mm CRS.

100m

m M

IN.

TIMBER

PRE-FINISHED FLASHING SLOTTEDBETWEEN PANEL ANDSECONDARY FLASHING

VAPOUR RESISTANT MASTIC SEALANT

0.55 SECONDARY FLASHINGFIXED TO PANEL BEFOREINSTALMENTPRE-FINISHED FLASHING WITH

15° FALL

DPC LAYER

75

50

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

BOTTOM OF CLADDING 01

16 / 2130.08.2016

Page 18: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFT THERMOPANEL

PRE-FINISHED FLASHING SLOTTEDBETWEEN PANEL ANDSECONDARY FLASHING

VAPOUR RESISTANT MASTIC SEALANT

DPC LAYER

SEALANT

FOAM BACKING ROD

SEALANT

ALUMINUM CHANNEL

Ø5mm RIVETS

CONCRETE

Ø6.5mm / 32 mm SHUREDRIVES @ 300mmCRS. OR AS SPECIFIED BY ENGINEER

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

BOTTOM OF CLADDING 02

17 / 2130.08.2016

Page 19: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFT THERMOPANEL

ø6mm DRAINAGEHOLES @ 1000 CRA

ø5mm RIVETS @ 300mm CRS.

Z

TIMBER

PRE-FINISHED FLASHING SLOTTEDBETWEEN PANEL ANDSECONDARY FLASHING

VAPOUR RESISTANT MASTIC SEALANT

0.55 SECONDARY FLASHINGFIXED TO PANEL BEFOREINSTALMENT

DPC LAYER

50

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

BOTTOM OF CLADDING 03

18 / 2130.08.2016

Page 20: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFT THERMOPANEL

TIMBER

VAPOUR RESISTANT MASTIC SEALANT

ALUMINIUM BASE SUPPORT CHANNEL

50

PRE-FINISHED SELF-TAPPING TEKSCREW

ø5mm RIVETS @ 300mm CRS.

SEALANT

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

BOTTOM OF CLADDING 04

19 / 2130.08.2016

Page 21: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

METALCRAFT THERMOPANEL WALL

STRUCTURE BY OTHERS

VAPOUR RESISTANT MASTIC SEALANT

ALUMINIUM BASE SUPPORT CHANNEL

50

PRE-FINISHED SELF-TAPPING TEKSCREW

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems 1 : 2

BOTTOM OF CLADDING 05

20 / 2130.08.2016

Page 22: stak-file01Stratus 5 Metalcraft Roofing01 WIP01 BIM© 2013 ...dvgdd8qyw67xs.cloudfront.net/1039/tpwd_thermopanel-eps-external... · dektite pipe flashing Ø5mm rivets @ 300mm crs

INTERNAL LINER FINISHES

SILKLINE FINISH

- ONE SIDE ONLY

MESA FINISH

- ONE SIDE ONLY

RIBBED FINISH

- AVAILABLE BOTH SIDES

15 30

2

107 4 12

127

939.8 39.8

97.5

21

THERMOPANEL EPS

FLAT FINISH - AVAILABLE BOTH SIDES

SCALE @ 1:5

SCALE @ 1:2

A= 50, 75, 100, 125,150, 200, 250mm

A

1200

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

ScaleDate SheetTPWD

Thermopanel Wall DetailsMetalcraftInsulated Panel Systems As indicated

PANEL PROFILE AND SIZE

21 / 2130.08.2016