st. lucie, unit 2 - refueling outage sl2-18, steam ...florida power & light company, 6501 s....

115
0 FPL Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re: St. Lucie Unit 2 Docket No. 50-389 Refueling Outage SL2-18 Steam Generator Tube Inspection Report Attached is the St. Lucie Unit 2 Technical Specification 6.9.1.12 steam generator tube inspection report for the spring 2009 refueling outage (SL2-18). This submittal was made within 180 days after the initial entry into hot shutdown following the completion of the steam generator inspection that was performed in accordance with TS 6.8.4.1, Steam Generator (SG) Program. Please contact Ken Frehafer at (772) 467-7748 should you have any questions regarding this submittal. Sincerely, Eric S. Katzman Licensing Manager St. Lucie Plant ESKIKWF Attachments - St. Lucie Unit 2 Steam Generator Tube Inspection Report - 10 pages SG 2A Indication Listings - 64 pages SG 2B Indication Listings - 40 pages AC )CO an FPL Group company

Upload: others

Post on 13-Sep-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

0FPL

Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957

November 9, 2009

L-2009-25410 CFR 50.55a

10 CFR 50.36

U. S. Nuclear Regulatory CommissionAttn: Document Control DeskWashington, DC 20555

Re: St. Lucie Unit 2Docket No. 50-389Refueling Outage SL2-18Steam Generator Tube Inspection Report

Attached is the St. Lucie Unit 2 Technical Specification 6.9.1.12 steam generator tube inspectionreport for the spring 2009 refueling outage (SL2-18). This submittal was made within 180 daysafter the initial entry into hot shutdown following the completion of the steam generator inspectionthat was performed in accordance with TS 6.8.4.1, Steam Generator (SG) Program.

Please contact Ken Frehafer at (772) 467-7748 should you have any questions regarding thissubmittal.

Sincerely,

Eric S. KatzmanLicensing ManagerSt. Lucie Plant

ESKIKWF

Attachments - St. Lucie Unit 2 Steam Generator Tube Inspection Report - 10 pagesSG 2A Indication Listings - 64 pagesSG 2B Indication Listings - 40 pages

AC )CO

an FPL Group company

Page 2: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Revision 0

Steam Generator Tube Inspection Report Page 1 of 10Enclosure 1

Background

This report is provided in accordance with St. Lucie Unit 2 Technical Specification 6.9.1.12, "SteamGenerator Tube Inspection Report" for the inspection conducted May 10-16, 2009 during refuelingoutage eighteen (SL2-18). SL2-18 is the first refueling outage following installation of the Areva-NPModel 86/19TI replacement steam generators (SGs) in December, 2007. The replacement SGshad accumulated 15.01 effective full power months of operation at the SL2-18 refueling outage.

Following the SL2-18 refueling outage, St. Lucie Unit 2 initially entered HOT SHUTDOWN on May29, 2009, which marks the beginning of the first sequential period of 144 EFPM.

The SL2-18 SG tube inspections were conducted in both 'A' and 'B' SGs as described below.

a. The scope of inspection performed on each steam generator

The scope of this examination is summarized in Table 1 below and is established to meet thefollowing requirements:

a. Technical Specification 6.8.4.1 "Steam Generator (SG) Program"

b. Technical Specification 6.8.4.1.1.d.1 "Inspect 100% of the tubes in each SG during the firstrefueling outage following SG replacement."

c. Steam Generator Management Program: Pressurized Water Reactor Steam GeneratorExamination Guidelines: Revision 7. EPRI, Palo Alto, CA: 2007. 1013706.

The basis for bobbin and +PointTM tube examinations is given in Table 1.

Page 3: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Revision 0Steam Generator Tube Inspection Report Page 2 of 10

Enclosure 1

TABLE 1BASIS FOR TUBE EXAMINATION SAMPLES

Technique Examination Sample Required or Basis PotentialI Supplemental_ Degradation

100% full length of all active Required Technical Specification SR Wearn tubes in each SG 4.4.5.1 and TS 6.8.4.1.1.d.1Bobbin tbsi ahS

HL & CL expansion transitions +/- Required SG Program Procedure Foreign3.0" from the top of tubesheet: ENG CSI-2.2, Rev. 29, Object Wear" The two outermost tubes Checklist item 1.D.

+PointJ exposed to the annulus." All tubes in Rows 1 through 4

along the tube free lane.

Tight radius u-bends - Supplemental Discretionary sample None* 20% of row 1 and 2

Sample of tubesheet expansion Supplemental Recommended by EPRI Noneanomalies, manufacturing burnish 1013706marks, unusual signals, and dingsobserved during the inspection

SG B Row 76 Column 103 Required Condition Report 2007- Nonerequires a full depth hot leg 20669 (Tubesheet drill holetubesheet rotating probe anomaly)examination (TSH +3.0" to TEH)

SG B Row 88 Column 93 requires Supplemental Pre-service Inspection Nonea top of tubesheet rotating probe Report Recommendationexamination to the extent of TSC (Tube Shaving signal)+3.0" to TSC -3.0" (Tube Shaving signal)

b. Active degradation mechanism found

The SL2-18 bobbin and +PointTM examination results for St. Lucie Unit 2 identified mechanical weardegradation at the following locations:

* Anti-vibration bar (AVB) contact points in the u-bends* Broached tube support contact points

Other than wear degradation as discussed above, there were no indications of any tubedegradation in the +Poinft probe examination samples identified in Table 1.

Page 4: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Revision 0

Steam Generator Tube Inspection Report Page 3 of 10Enclosure 1

c. Nondestructive examination techniques utilized for each degradation mechanism

TABLE 2 - St. Lucie Unit 2 Examination Techniques for EOC 17 (April 2009)

Industry Damage Demonstrated Extended Depth Sizing Site-Specific ReviewTechnique Technique Deemed Acceptable

Qualification Mechanism Applicability Applicability Applied Detection Sizing

Differential Mix

1 Bobbin 96004.1 Wear Structures None Amplitude Yes For ServiceRevision I W Analysis

(Using Vert-Max)Absolute Mix Contingent

2 Bobbin 96004.2 Wear Structures None Amplitude Yes Sizing ofRevision 11 Analysis

(Using Vert-Max) WearStructures, Differential Mix Contingent

3 Pont M 96910.1 Freespan Amplitude YesnSiingeof3 .+PointTM R6o10 Wear Broached supports PLP Wear Analitude

(When Part (Using Vert-Max) WearPresent)

27091.2 PLP Wear4 Bobbin Revision 0 PLP Wear PLP Wear (When Part N/A Yes N/A

R 0(part not present) Present)

n 24013.1 Freespan,5 Bobbin 24013.1 Axial ODSCC Dings None N/A Yes N/ARevision 2<50Vot

<_ 5.00 Volts

21998.1 Volumetric Single Frequency Contingent6 +PointTM 21998.1 V eFreespan None Amplitude Yes Sizing ofRevision 4 Analysis Peak to Wear

Peak

7 22401.1 Dented Support Dent / Ding Single Frequency+PointTM Revision 4 Axial ODSCC Structures Freespan Phase Analysis Yes For Info

& U-bend

22842.3 Dented Support Dent / Ding Single FrequencyRevision 5 irc Structures Freespan Phase Analysis

& U-bend

9 +PointTM 20510.1 Circ PWSCC Expansion None Single Frequency Yes For InfoRevision 7 Transition Phase Analysis

10 +PointTm 20511.1 Axial PWSCC Expansion None Single Frequency Yes For InfoRevision 8 Transition Phase Analysis

11 +PointTM 96703.1 Axial PWSCC Dents Freespan Single Frequency Yes For InfoRevision 17 Phase Analysis

27901.127902.127903.1 PLP Wear

PLP Wear12 +PointTM 27904.1 PLP Wear Morphology None Morphology Yes For Service

27905.1 Dependent Dependent27906.1 (part not present)27907.1

(All Rev. 0)

13 +PointTM 96511.2 Axial & Circ Low Row Single FrequencyRevision 16 PWSCC U-bends None Phase Analysis Yes For Info

Page 5: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Revision 0Steam Generator Tube Inspection Report Page 4 of 10

Enclosure 1

d. Location orientation (if linear) and measured sizes (if available) of service inducedindications

Please see Attachment 1 and 2 for indication listings for SG 2A and 2B respectively.

e. Number of tubes plugged during the inspection for each active degradation mechanism

St. Lucie Unit 2 Tube Plugging EOC'17

Degradation Mechanism

Wear at Anti-vibration bar (AVB) tubecontacts (greater than or equal to 24%)

Wear at Broached Support locationsWear at Broached Support locations

Loose Part Wear(1) Row 80 column 17 in SG 2B was preventively plugged due to two indications located at

Total

(1) Row 80 column 17 in SG 2B was preventively plugged due to two indications located atAVB stiffeners (supports/appui) adjacent to AV3 and AV4. Refer to Figure 4.

f. Total number and percentage of tubes plugged to date

St. Lucie Unit 2 Steam Generator CumulativeTube Plugging Summary EOC 17

SG # Plugged % Plugged

2A 8 0.0898%

2B 6 0.067%

Page 6: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Revision 0Steam Generator Tube Inspection Report Page 5 of 10

Enclosure 1

g. The results of condition monitoring including the results of the tube pulls and in-situtesting

All tubes inspected met the tube integrity performance criteria in TS 6.8.4.1.1.b and conditionmonitoring requirements. No tubes required in-situ pressure testing. No tube pulls wererequired.

h. The effective plugging percentage for all plugging in each steam generator

No tube repair methods (i.e. sleeving) are approved for St. Lucie Unit 2 that would have aneffect on the effective plugging percentages. Therefore, the applicable effective pluggingpercentage is synonymous with the % Plugged in item f. above.

Abbreviations

CSI - Component Support and InspectionsSG - Steam GeneratorISI - In-service InspectionECT - Eddy Current TestingNEI - Nuclear Energy InstituteEPRI - Electric Power Research Institute

Acronyms

H/L - Hot LegC/L - Cold LegVOL - Volumetric IndicationSVI - Single Volumetric IndicationPIT - Pit IndicationPLP - Possible Loose PartWAR - Mechanical WearTWD - Through Wall DepthTSH - Tubesheet Hot LegTEH - Tube End Hot LegTSC - Tubesheet Cold LegTEC - Tube End ColdPTP - Preventative Tube Plug

The last four pages of this document show a side view of the installed St. Lucie Unit 2 RSGs, a detailedview of the fan bar arrangement and support locations, a table showing the distances between thesupport structures in the SGs, and the AVB stiffener configuration in the u-bends.

Page 7: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Revision 0Steam Generator Tube Inspection Report Page 6 of 10

Enclosure 1

ADDITIONAL INFORMATION

The following information is included to assist the staff in their review of the information provided in this

report.

Secondary Side Inspection

Secondary side inspection information is not required by TS Section 6.9.1.12. However, thisinformation is being provided based on NRC requests for additional information regarding previousreports submitted by FPL in accordance with this specification:

Secondary Side Inspections (SSI) during the SL2-18 refueling outage include the following:

* Sludge Lance" FOSAR (Foreign Object Search and Retrieval)= Steam Drum Inspections

Sludge lancing was completed in both steam generators. The process recovered 29.5 lbs of sludgefrom SG A and 24 lbs from SG B. Pre and post lancing visual inspection was completed in bothSGs. During the prelance inspection of SG A, a piece of ferritic machine turning was removed fromthe cold leg annulus trough region. During post-lance inspections of SG A, a piece of flexitalicgasket was located adjacent to row 127 column 88 and was removed. Bobbin and rotating probeeddy current examination of these locations and the surrounding tubes revealed no tube damage.

Steam drum inspections consisted of 1) stabilizers and water level taps, 2) recirculation pipe flangeassembly, 3) feedring inspection port covers, 4) wrapper room hatches, 5) manway hatch to top ofdryers, 6) dryer vanes, 7) lower separator support stuck studs, 8) loose parts tapping system. Theareas of inspection are depicted in Figure 1. In SG B, a .25" round spherical object was removedfrom the loose part trapping system screen. Visual inspection of the feedring inspection portcovers in SG B revealed that one closure bolt was backed out by about .25" and that five additionalbolts were not fully engaged, although the locking tabs were correctly installed. A subsequentinspection of the SG A feedring inspection port covers revealed a similar condition was present forall eight fasteners. These conditions were addressed in the corrective action program and allfasteners were re-torqued to manufacturer's specifications. No other anomalous conditions werenoted.

Page 8: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Revision 0Steam Generator Tube Inspection Report Page 7 of 10

Enclosure 1

Figure 1

0 & M Warranty Inspection Areas

Stabilizers andWater Level Taps

Recirculation2 Pipe Flange

Assembly

Feedring3 Inspection port

covers

4 Wrapper RoomHatches

5 Manway Hatch toTop of Dyers

6 Dryer Vanes

Lower Separator7 Support Stuck

Studs

8 Loose PartsTrapping System

Page 9: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Revision 0Steam Generator Tube Inspection Report Page 8 of 10

Enclosure 1

Figure 2

Figure 2-2 - PSL-2 RSG Tube Support and AVB Layout

Page 10: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Revision 0Steam Generator Tube Inspection Report Page 9 of 10

Enclosure 1

Figure 3

FIGURE 13-2PSL-2 Steam Generator

Elevations and Structure Acronyms

INCREMENTALDEFINITION DISTANCE

CUMULATIVEDISTANCECODE

DEFINITION DISTANCE

THE Hot Leg Tube End 0.0"

TSH Hot Leg Tube Sheet 23.09" (Nominal)

01H #1 Tube Support Hot Leg TSH - 01H 23.82"

02H #2 Tube Support Hot Leg 01 H - 02H 38.50"

03H #3 Tube Support Hot Leg 02H - 03H 41.58"

04H #4 Tube Support Hot Leg 03H - 04H 41.57"

05H #5 Tube Support Hot Leg 04H - 05H 41.58"

06H #6 Tube Support Hot Leg 05H - 06H 41.57"

07H #7 Tube Support Hot Leg 06H - 07H 29.61"

AV1 #1 Anti-Vibration Bar Variable

AV2 #2 Anti-Vibration Bar Variable

AV3 #3 Anti-Vibration Bar Variable

AV4 #4 Anti-Vibration Bar Variable

AV5 #5 Anti-Vibration Bar Variable

AV6 #6 Anti-Vibration Bar Variable

AV7 #7 Anti-Vibration Bar Variable

AV8 #8 Anti-Vibration Bar Variable

07C #7 Tube Support Hot Leg 07C - 06C

'DISTANCE MEASUREMENTS ARE CENTER TO CENTER

0.0"

23.09"

46.91"

85.41"

126.99"

168.56"

210.14"

251.71"

281.32"

Page 11: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Revision 0Steam Generator Tube Inspection Report Page 10 of 10

Enclosure 1

Figure 4

Anti Vibration Bar (AVB) Stiffener (APPUI)Typical Configuration

CLAMPBRIDE ANMN-ISRAM1N BAR

EARTF2 ANTI-WIBRAI1ON

SUPPORTAPPUI

HOOP -

CERCE

U SHAPEDCAVALIER EN U

Page 12: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure I

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 1 of 64

SG 2A Indication Listings

Listing Description Page No.

Tubes Plugged Listing 2

Bobbin WEAR at AVB locations 20-100%TWD 3

Bobbin WEAR at Broached Supports 20-100% TWVD 4

Bobbin WEAR at Broached Supports 1-19% TWD 4

WEAR (WAR) sized by +PointTM probe 1-100% 4

SG 2A Wear Indications 1-19% TWD at AVB locations 8

Page 13: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 2 of 64

St. Lucie Unit 2 (SL2-18)SG 2A Tubes Plugged Listing

ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL# LEG PROBE

54 161 0.21 117 P2 TWD 11 AV7 +0.18 TEC TEH 18 HOT 610UL0.86 112 P3 TWD 33 AVG -0.29 TEC TEH LAR 18 HOT G6OUL0.24 78 P2 TWD 12 AV2 +0.20 TEC TEH 18 HOT 61OUL0.37 125 P2 TWD 16 AV6 +0.20 TEC TEH 18 HOT 61OUL

..........................................................................................................

59 158 0.15 92 P2 TWD 8 AVG -0.27 TEC TEH 20 HOT 610UL0.51 123 P3 TWD 26 AV3 +0.31 TEC TEH 20 HOT 610UL

..........................................................................................................

63 158 0.13 120 P3 TWD 10 AV7 +0.11 TEC TEH 20 HOT 610ULL0.22 11 P3 TWD 15 AVG -0.29 TEC TEH 20 HOT 610ULT0.95 I11 P3 TWD 35 AV3 +0.22 TEC TEH 20 HOT 61OUL0.37 104 P3 TWD 22 AV2 +0.18 TEC TEH 20 HOT 61OUL

118 85 0.28 136 P2 TWD 11 AV2 +0.071.06 Ill P2 TWD 27 AV3 -0.020.22 136 P2 TWD 9 AV4 +0.020.48 123 P2 TWD 16 AV5 +0.040.61 119 P2 TWD 19 AVG +0.070.20 119 P2 TWD 8 AV8 +0.09

119 92 0.41 126 P2 TWD 14 AV2 +0.001.01 118 P2 TWD 25 AV3 +0.000.13 104 P2 TWD 5 AV4 +0.000.43 127 P2 TWD 14 AV5 +0.000.43 130 P2 TWD 14 AV6 +0.00

TEH TEC 23 COLD 610ULTEH TEC 23 COLD 81OULTEH TEC 23 COLD 610ULTEH TEC 23 COLD 610ULTEH TEC 23 COLD 610ULTEH TEC 23 COLD 610ULTEN....TE ..... 48...COLD....610.....1,.

TEH TEC 48 COLD 61OULTEH TEC 48 COLD 610ULTEH TEC 48 COLD 610ULTEN TEC 48 COLD 61OULTEH TEC 48 COLD 610UL

128 83 0.47 120 P2 TWD 16 AV2 +0.00 TEH TEC 24 COLD 610UL0.39 124 P2 TWD 14 AV3 +0.00 TEH TEC 24 COLD 610UL0.25 127 P2 TWD 10 AV4 +0.00 TEH TEC 24 COLD 610UL0.98 115 P2 TWD 25 AVS +0.00 TEH TEC 24 COLD 610UL0.25 114 P2 TWD 10 AVG +0.00 TEH TEC 24 COLD 610UL0.20 131 P2 TWD 8 AV7 +0.00 TEH TEC 24 COLD 610UL

133 90 0.27 116 P2 TWD 9 AVI -0.04 TEH TEC 47 COLD 610UL0.39 106 P2 TWD 12 AV2 -0.20 TEH TEC 47 COLD 610UL0.50 118 P2 TWD 15 AV4 -0.09 TEH TEC 47 COLD 610UL1.07 118 P2 TWH 25 AV5 -0.04 TER TEC 47 COLD 610UL0.32 120 P2 TWD 11 AV7 +0.04 TEH TEC 47 COLD 610UL

..........................................................................................................

137 82 1.08 116 P2 TWD 26 AV4 +0.00 TEH TEC 37 COLD 610UL0.33 126 P2 TWD 12 AVG +0.00 TEH TEC 37 COLD 610UL0.43 125 P2 TWD 14 AV7 +0.00 TEH TEC 37 COLD 610UL0.16 121 P2 TWD 6 AVS +0.00 TEH TEC LAR 37 COLD 610UL

Total Tubes : 8Total Records: 36

Page 14: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 3 of 64

St. Lucie Unit 2 SG 2A (SL2-18)Bobbin WEAR at AVB locations 20-100%TWD

ROW

5154545963

7384939498100101102103104104108109109Ill112113114116117117118119120121122122123124126128130133133135136137

COL VOLTS

162 0.629 0.58161 0.86158 0.51158 0.95

0.3798 0.86103 0.6786 0.7385 0.9185 0.6385 0.6288 0.7585 0.6484 0.6587 0.7189 0.7985 0.6384 0.7386 0.6784 0.7285 0.7084 0.6991 0.7983 0.6682 0.7184 0.8685 1.0692 1.0185 0.7284 0.8683 0.6385 0.7884 0.7691 0.7589 0.7883 0.9885 0.7684 0.7590 1.0782 0.6993 0.7682 1.08

DEG CHN

120 P2118 P2112 P3123 P3I11 P3104 P3119 P2112 P2117 P2114 P2113 P2111 P2109 P2124 P2124 P2116 P2116 P2117 P2117 P2116 P2115 P2120 P2117 P2117 P2113 P2118 P2117 P2111 P2118 P2114 P2Ill P2117 P2115 P2115 P2123 P2121 P2115 P2120 P2118 P2118 P2120 P2106 P2116 P2

IND %TW LOCATION

TWD 22 AV6 +0.15TWD 22 AV3 -0.18TND 33 AV6 -0.29TND 26 AV3 +0.31TWD 35 AV3 +0.22T2D 22 AV2 +0.18TWD 23 AV5 +0.00TWD 20 AV2 +0.00TWD 22 AV5 +0.00TWD 24 AV3 +0.02TWD 20 AV6 +0.02TWD 20 AV4 +0.00TWD 20 AVG -0.02TWD 20 AV2 +0.07TWD 20 AV7 +0.02TWD 21 AVG +0.00TWD 21 AV6 +0.04TND 20 AV7 +0.00TWD 22 AV2 +0.00TND 21 AV5 +0.00TND 21 AV2 +0.00

W-D 21 AV7 +0.00TND 21 AV2 +0.00TWD 21 AV3 +0.00TWD 20 AVG +0.00TWD 21 AVG +0.00TND 24 AVG +0.07TND 27 AV3 -0.02T•D 25 AV3 +0.00TND 21 AV7 +0.00TND 24 AV2 +0.00TND 20 AV5 +0.04TWD 22 AV3 -0.02TWD 22 AV7 -0.02TND 21 AV4 +0.00TND 21 AV3 +0.13TWD 25 AV5 +0.00TWD 22 AVG +0.09TND 22 AV5 +0.00TWD 25 AV5 -0.04T2D 20 AV4 +0.002ND 23 AV4 +0.04TWD 26 AV4 +0.00

EXT EXT UTIL I UTIL 2

TEC TEHTEC TEHTEC TEH LARTEC TEHTEC TEETEC TEHTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEN TECTEH TEC

CAL #

18581820202051564523232447232345472424452324244824262323482424232323484724232447373837

LEG PROBE

HOT 61OULHOT 61OULHOT 61SULHOT 61LUTLHOT 610ULHOT GlOULCOLD 61OULCOLD 61OULCOLD 61OULCOLD 61OULCOLD 61OUL

COLD StoULCOLD 61OULCOLD 61OULCOLD G6OULCOLD 610ULCOLD G6OUL

COLD G6OULCOLD 61OULCOLD 610ULCOLD 61OULCOLD G6OULCOLD 61OULCOLD 61oULCOLD 61OULCOLD 61OULCOLD 61OULCOLD 610ULCOLD 61ULCOLD 61OULCOLD 610ULCOLD 61OULCOLD 61OULCOLD 61OULCOLD 61oULCOLD 61OULCOLD G6OULCOLD 61oULCOLD 61OULCOLD GlOULCOLD 61oULCOLD 61OULtCOLD 61OUL

Total Tubes : 42Total Records: 47

Page 15: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 4 of 64

St. Lucie Unit 2 SG 2A (SL2-18)Bobbin WEAR at Broached Supports 20-100% TWD

ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

Total Tubes : 0Total Records: 0

(None)

St. Lucie Unit 2 SG 2A (SL2-18)Bobbin WEAR at Broached Supports 1-19% TWD

ROW

2770909196132

COL

7215133242991

VOLTS DEG CHN

0.12 129 P30.12 88 P30.10 119 P30.09 135 P30.11 130 P30.10 132 P30.14 129 P3

IND %TW

TWO 8

TWD 7TWD 8TWD 6TWD 9TWO 8TWD 8

LOCATION

04C -0.7404C +0.510SC +0.5104H -0.6404H -0.7304H -0.7505C +0.43

EXT EXT UTIL 1 UTIL 2 CAL #

07H TEC 83TEC TEH 62TEC TEH 20TEH TEC iiTEC TEH 54TEC TEH 54TEH TEC 48

LEG PROBE

COLD 61OULHOT 61OULHOT 61OULCOLD 61OULHOT 61OULHOT 61OULCOLD 610UL

Total Tubes : 7Total Records: 7

St. Lucie Unit 2 SG 2A (SL2-18)WEAR (WAR) sized by +PointTM probe 1-100% (TWD located in UTIL 1 column)(Confirmed as two sided wear & reported as DSI by Bobbin probe)

ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

97 84 0.63 120 P2 DSI AV7 +0.00 TEH TEC LAR 20 24 COLD 61OUL0.48 93 PS WAR AV7 +0.02 AV7 AV7 16 96910.1 77 COLD 5601P0.33 99 PS WAR AV7 +0.10 AV7 AV7 12 96910.1 77 COLD 5601P

98.89.0.38....94...P....WAR....AV6....-0..04....A...............13....96910.....1...77....COLD............

98 89 0.38 94 P5 WAR AVG -0.04 AVG AV6 13 96910.1 77 COLD 5601P0.53 88 P5 WAR AV6 -0.03 AV6 AV6 17 96910.1 77 COLD 5601P

0.72 126 P2 DSI AVG +0.00 TEH TEC LAR 20 47 COLD 61OUL..........................................................................................................

101 84 0.42 88 PS WAR AV7 -0.03 AV7 AV7 19 96910.1 42 COLD 5601P0.68 118 P2 DSI AV7 +0.00 TEH TEC LAR 21 24 COLD 610UL0.22 93 PS WAR AV7 +0.02 AV7 AV7 12 96910.1 42 COLD 5601P

102 83 0.57 107 PS WAR AV4 -0.03 AV4 AV4 14 96910.1 43 HOT 5601P0.70 123 P2 DSI AV4 -0.02 TEH TEC LAR 21 23 COLD 610UL0.56 110 PS WAR AV4 +0.13 AV4 AV2 14 96910.1 43 HOT 5601P

104 87 0.16 85 P5 WAR AV4 -0.10 AV4 AV4 10 96910.1 71 HOT 5601P0.66 121 P2 DSI AV4 +0.00 TEH TEC LAR 20 45 COLD 61OUL0.38 87 P5 WAR AV4 +0.01 AV4 AV4 21 96910.1 71 HOT 5601P0.78 117 P2 DSI AV5 +0.00 TEH TEC LAR 22 45 COLD 61OUL0.19 97 P5 WAR AV5 +0.02 AV6 AV5 7 96910.1 77 COLD 5601P0.70 90 PS WAR AVS +0.14 AV6 AV5 21 96910.1 77 COLD 5601P

..........................................................................................................

Page 16: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Rev. 0Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1 SG 2A, Page 5 of 64

WEAR (WAR) sized by +PointTM probe 1-100% (TWD located in UTIL I column) (continued)(Confirmed as two sided wear & reported as DSI by Bobbin probe)

ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

105 84 0.36 90 PS WAR AV2 - 0.06 AV2 AV4 20 96910.1 71 HOT 5601P

0.17 91 PS WAR AV2 -0.00 AV2 AV4 11 96910.1 71 HOT 5601P0.73 117 P2 DWA AV2 +0.00 TEA TEC LAR 22 24 COLD 91OtOL

0.84 119 P2 DSI AV7 +0.00 TEH TEC LAR 23 24 COLD 61OUL0.73 106 PS WAR AV7 +0.02 AV7 AVG 19 96910.1 43 COLD 5601P0.45 109 P5 WAR AV7 +0.03 AV7 AVG 12 96910.1 43 COLD 5601P0.45 109 P5 WAR AV7 +0.03 AV7 AV6 12 96910.1 43 COLD 5601P------- ---- -------------

105 86 0.41 88 PS WAR AV3 -0.10 AV3 AV3 22 96910.1 71 HOT 5601P0.15 102 PS WAR AV3 -0.06 AV3 AV3 10 96910.1 71 HOT 5601P0.72 116 P2 DSI AV3 +0.00 TEH TEC LAR 21 45 COLD 61OUL

..........................................................................................................

106 83 0.48 107 P5 WAR AVS +0.01 AVS AV4 13 96910.1 43 COLD 5601P0.64 122 P2 DSI AVS +0.15 TEH TEC LAR 20 23 COLD 61OUL0.60 109 PS WAR AVS +0.18 AVS AV4 16 96910.1 43 COLD 5601P

..........................................................................................................

106 87 0.82 122 P2 DSI AV5 +0.00 TEH TEC LAR 22 44 COLD 6100L0.31 94 P5 WAR AVS +0.05 AVS AV5 11 96910.1 77 COLD 5601P0.65 90 PS WAR AVS +0.11 AV5 AVS 20 96910.1 77 COLD 5601P

..........................................................................................................

107 84 0.74 124 P2 DSI AV2 +0.00 TEH TEC LAR 22 23 COLD 61OUL0.60 107 P5 WAR AV2 +0.01 AVI AV2 15 96910.1 43 HOT 5601P0.71 108 P5 WAR AV2 +0.10 AVI AV2 17 96910.1 43 HOT 5601P0.95 121 P2 DSI AV7 +0.02 TEH TEC LAR 25 23 COLD 61OUL0.79 108 PS WAR AV7 +0.08 AV7 AV6 20 96910.1 43 COLD 5601P0.49 111 P5 WAR AV7 +0.09 AV7 AVG 13 96910.1 43 COLD 5601P

108 87 0.70 122 P2 DSI AVS +0.00 TEH TEC LAR 21 45 COLD 61OUL0.38 95 PS WAR AVS +0.17 AV7 AV5 13 96910.1 77 COLD 5601P0.47 90 PS WAR AV5 +0.21 AV7 AV5 15 96910.1 77 COLD 5601P0.72 119 P2 DSI AV6 +0.00 TEH TEC LAR 21 45 COLD 610UL0.35 94 P5 WAR AVG +0.05 AV7 AVS 12 96910.1 77 COLD 5601P0.55 92 P5 WAR AV6 +0.08 AV7 AV5 18 96910.1 77 COLD 5601P0.38 92 P5 WAR AV7 -0.14 AV7 AV5 14 96910.1 77 COLD 5601P0.45 89 P5 WAR AV7 -0.10 AV7 AV5 15 96910.1 77 COLD 5601P0.68 124 P2 DSI AV7 +0.00 TEH TEC LAR 21 45 COLD 610UL

..........................................................................................................

108 89 0.28 88 P5 WAR AV4 -0.07 AV4 AV4 16 96910.1 71 HOT 5601P0.73 119 P2 DSI AV4 +0.00 TEH TEC LAR 20 47 COLD 610UL0.35 93 P5 WAR AV4 +0.07 AV4 AV4 20 96910.1 71 HOT 5601P

..........................................................................................................

109 84 0.74 104 P5 WAR AV7 -0.02 AV7 AV6 19 96910.1 43 COLD 5601P0.27 106 P5 WAR AV7 -0.01 AV7 AV6 8 96910.1 43 COLD 5601P0.70 118 P2 DSI AV7 +0.00 TEH TEC LAR 21 24 COLD 61OUL

110 83 0.59 109 P5 WAR AV4 -0.00 AVE AV4 16 96910.1 43 COLD 5601P0.64 125 P2 DSI AV4 +0.04 TEH TEC LAR 20 23 COLD 61OUL0.45 107 P5 WAR AV4 +0.06 AVG AV4 12 96910.1 43 COLD 5601P0.65 108 P5 WAR AV5 +0.05 AVG AV4 17 96910.1 43 COLD 5601P0.46 107 P5 WAR AV5 +0.07 AVG AV4 13 96910.1 43 COLD 5601P0.70 124 P2 DSI AV5 +0.07 TEH TEC LAR 21 23 COLD 61OUL0.68 105 P5 WAR AVG -0.10 AVG AV4 10 96910.1 43 COLD 5601P0.68 105 P5 WAR AVG +0.05 AVG AV4 18 96910.1 43 COLD 5601P0.89 125 P2 DSI AVG +0.09 TEH TEC LAR 24 23 COLD 61OUL

..........................................................................................................

110 85 0.11 113 P5 WAR AV2 -0.04 AV2 AV2 3 96910.1 42 HOT 5601P0.69 123 P2 DSI AV2 +0.04 TEH TEC LAR 21 23 COLD 61OUL0.80 108 P5 WAR AV2 +0.19 AV2 AV2 21 96910.1 42 HOT 5601P

..........................................................................................................

Ill 84 0.90 122 P2 DSI AV7 +0.00 TEH TEC LAR 24 23 COLD 61OUL0.89 108 P5 WAR AV7 +0.09 AV7 AVG 22 96910.1 43 COLD 5601P0.38 104 PS WAR AV7 +0.13 AV7 AVG 11 96910.1 43 COLD 5601P

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .- ------- ------

Page 17: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Rev. 0Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1 SG 2A, Page 6 of 64

WEAR (WAR) sized by +PointTM probe 1-100% (TWD located in UTIL I column) (continued)(Confirmed as two sided wear & reported as DSI by Bobbin probe)

ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

ill 88 0.29 90 PS WAR AV3 -0.09 AV3 AV3 17 96910.1 71 HOT 560190.42 87 P5 WAR AV3 -0.02 AV3 AV3 23 96910.1 71 HOT 5601P0.94 120 P2 DSI AV3 +0.00 TEH TEC LAR 23 46 COLD 61OUL0.55 89 P5 WAR AVG +0.00 AV6 AV6 17 96910.1 77 COLD 5601P0.99 122 P2 DSI AVG +0.00 TEH TEC LAR 24 46 COLD 61OUL0.62 93 PS WAR AVG +0.04 AV6 AVG 19 96910.1 77 COLD 5601P

..........................................................................................................

112 91 0.22 93 P5 WAR AV3 -0.11 AV3 AV3 14 96910.1 71 HOT 5601P0.69 122 P2 DSI AV3 +0.00 TER TEC LAR 20 48 COLD 610UL0.35 92 P5 WAR AV3 +0.13 AV3 AV3 20 96910.1 71 HOT 5601P

..........................................................................................................

113 84 0.63 123 P2 DSI AV5 +0.00 TEH TEC LAR 20 24 COLD G6OUL0.56 105 PS WAR AV5 +0.09 AV5 AV4 15 96910.1 43 COLD 5601P0.47 108 P5 WAR AV5 +0.10 AV5 AV4 13 96910.1 43 COLD 5601P0.95 116 P2 DSI AV7 +0.00 TEH TEC LAR 25 24 COLD 61OUL0.95 104 P5 WAR AV7 +0.01 AV7 AVG 23 96910.1 43 COLD 5601P0.19 100 P5 WAR AV7 +0.05 AV7 AVG 6 96910.1 43 COLD 5601P

115 86 0.13 89 P5 WAR AVG -0.09 AV7 AVG 5 96910.1 77 COLD 5601P0.68 121 P2 DSI AVG +0.00 TEH TEC LAR 20 44 COLD 61OUL0.64 91 P5 WAR AVG +0.16 AV7 AVG 20 96910.1 77 COLD 5601P0.70 121 P2 DSI AV7 +0.00 TEH TEC LAR 20 44 COLD 61OUL0.44 94 PS WAR AV7 +0.09 AV7 AVG 15 96910.1 77 COLD 5601P0.37 88 P5 WAR AV7 +0.10 AV7 AVG 13 96910.1 77 COLD 5601P

..........................................................................................................

115 88 0.72 120 P2 DSI AVG +0.04 TEH TEC LAR 20 46 COLD G1OUL0.57 92 PS WAR AVG +0.07 AVG AVG 18 96910.1 77 COLD 5601P0.33 93 PS WAR AVG +0.08 AVG AVG 11 96910.1 77 COLD 5601P

..........................................................................................................

116 83 0.68 109 P5 WAR AV2 -0.18 AV2 AV2 17 96910.1 43 HOT 5601P0.64 121 P2 DSI AV2 +0,00 TEH TEC LAR 20 24 COLD 61OUL0.45 109 P5 WAR AV2 +0.15 AV2 AV2 11 96910.1 43 HOT 5601P0.50 108 P5 WAR AV7 -0.09 AV7 AVG 14 96910.1 43 COLD 5601P0.71 120 P2 DSI AV7 +0.00 TEH TEC LAR 21 24 COLD 61OUL0.57 109 P5 WAR AV7 +0.06 AV7 AVG 15 96910.1 43 COLD 5601P

..........................................................................................................

116 85 0.47 110 PS WAR AV2 -0.12 AVl AV2 13 96910.1 42 HOT 5601P0.75 120 P2 DSI AV2 +0.00 TEH TEC LAR 22 24 COLD 61OUL0.67 110 P5" WAR AV2 +0.08 AVI AV2 18 96910.1 42 HOT 5601P

..........................................................................................................

116 89 0.59 91 P5 WAR AVG -0.11 AVG AVG 19 96910.1 77 COLD 5601P0.76 123 P2 DSI AVG +0.00 TEH TEC LAR 20 47 COLD 61OUL0.36 91 P5 WAR AVG +0.07 AVG AVG 12 96910.1 77 COLD 5601P

117 82 0.48 104 P5 WAR AV3 -0.05 AV3 AV3 12 96910.1 43 HOT 5601P0.64 118 P2 DSI AV3 +0.00 TEH TEC LAR 20 26 COLD 61OUL0.53 110 P5 WAR AV3 +0.16 AV3 AV3 13 96910.1 43 HOT 5601P

117.84.0.67....107.........WAR.....V7....-0.04.....A...7..AV.....17...96910.1.......43...COLD.............

117 84 0.67 107 P5 WAR AV7 -0.04 AV7 AVG 17 96910.1 43 COLD 5601P0.58 108 PS WAR AV7 -0.03 AV7 AV6 15 96910.1 43 COLD 5601P

0.82 123 P2 DSI AV7 +0.04 TEH TEC LAR 23 23 COLD 61OUL..........................................................................................................

118 85 0.75 110 P5 WAR AV7 +0.02 AV7 AVG 19 96910.1 43 COLD 5601P0.74 127 P2 DSI AV7 +0.07 TEH TEC LAR 22 23 COLD 61OUL0.35 112 P5 WAR AV7 +0.09 AV7 AVG 10 96910.1 43 COLD 5601P

..........................................................................................................

119 84 0.18 108 PS WAR AV7 +0.02 AV7 AVG 5 96910.1 43 COLD 5601P0.82 106 P5 WAR AV7 +0.06 AV7 AVG 20 96910.1 43 COLD 5601P0.65 120 P2 DSI AV7 +0.07 TEH TEC LAR 20 23 COLD 61OUL

..........................................................................................................

120 83 0.50 110 PS WAR AVG -0.10 AV5 AV4 14 96910.1 43 COLD 5601P0.62 125 P2 DSI AV5 +0.00 TEH TEC LAR 20 24 COLD G1OUL0.61 109 P5 WAR AVG +0.01 AVG AV4 16 96910.1 43 COLD 5601P

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .- ---------

Page 18: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Rev. 0Steam Generator Tube Inspection Report

Attachment 1 to Enclosure I SG 2A, Page 7 of 64

WEAR (WAR) sized by +PointTM probe 1-100% (TWD located in UTIL I column) (continued)

(Confirmed as two sided wear & reported as DSI by Bobbin probe)

ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

121 84 0.65 108 P5 WAR AVS -0.07 AV2 AV5 17 96910.1 42 HOT 5601P0.69 117 P2 DSI AV5 +0.00 TEH TEC LAR 21 24 COLD 61OUL0.41 104 P5 WAR AV5 +0.14 AV2 AV5 12 96910.1 42 HOT 5601P0.65 122 P2 DSI AV7 +0.00 TEH TEC LAR 20 24 COLD 61OUL0.42 112 PS WAR AV7 +0.07 AV7 AVG 12 96910.1 43 COLD 5601P0.68 108 P5 WAR AV7 +0.24 AV7 AVG 18 96910.1 43 COLD 5601P

..........................................................................................................

121 86 0.48 93 P5 WAR AV5 -0.08 AVG AV5 16 96910.1 77 COLD 5601P0.69 118 P2 DSI AV5 +0.00 TEH TEC LAR 21 45 COLD 61OUL0.37 91 P5 WAR AV5 +0.07 AV6 AV5 13 96910.1 77 COLD 5601P0.80 117 P2 DSI AVG +0.00 TER TEC LAR 23 45 COLD 61OUL0.53 91 P5 WAR AV6 +0.07 AVG AVG 17 96910.1 77 COLD 5601P0.44 92 PS WAR AV6 +0.08 AV6 AV5 15 96910.1 77 COLD 5601P

124 83 0.78 107 P5 WAR AV2 -0.04 AV2 AV3 19 96910.1 43 HOT 5601P0.68 116 P2 DSI AV2 +0.00 TEH TEC LAR 21 24 COLD G6OUL0.32 112 P5 WAR AV2 +0.09 AV2 AV3 8 96910.1 43 HOT 5601P0.66 121 P2 DSI AV3 +0.00 TEH TEC LAR 20 24 COLD 1OUL0.49 I11 PS WAR AV3 +0.07 AV2 AV3 12 96910.1 43 HOT 5601P0.52 111 P5 WAR AV3 +0.08 AV2 AV3 13 96910.1 43 HOT 5601P

125 86 0.65 126 P2 DSI AV6 -0.04 TEH TEC LAR 20 45 COLD 61OUL0.37 94 PS WAR AVG -0.02 AVG AVG 13 96910.1 77 COLD 5601P0.48 93 P5 WAR AVG -0.00 AVG AV6 16 96910.1 77 COLD 5601P

..........................................................................................................

126 83 0.35 113 P5 WAR AV5 -0.33 AV5 AV4 10 96910.1 43 COLD 5601P0.78 117 P2 DSI AV5 +0.00 TEH TEC LAR 22 23 COLD G1OUL0.97 106 P5 WAR AV5 +0.42 AV5 AV4 23 96910.1 43 COLD 5601P

127 82 0.52 108 P5 WAR AVG -0.06 AV6 AV5 14 96910.1 43 COLD 5601P0.71 122 P2 DSI AVG +0.00 TEH TEC LAR 21 26 COLD 61OUL0.63 110 PS WAR AVG +0.16 AVG AV5 17 96910.1 43 COLD 5601P

127 84 0.65 127 P2 DSI AV5 +0.07 TEN TEC LAR 20 23 COLD 61OUL0.64 114 P5 WAR AVG +0.15 AV5 AV4 17 96910.1 43 COLD 5601P0.49 107 P5 WAR AV5 +0.21 AV5 AV4 13 96910.1 43 COLD 5601P

..........................................................................................................

129 84 0.89 123 P2 DSI AV5 +0.00 TEH TEC LAR 24 24 COLD 61OUL0.82 107 P5 WAR AV5 +0.01 AV5 AV4 20 96910.1 43 COLD 5601P0.64 106 P5 WAR AV5 +0.20 AV5 AV4 17 96910.1 43 COLD 5601P0.57 105 PS WAR AV7 -0.06 AV7 AVG 15 96910.1 43 COLD 5601P0.58 107 PS WAR AV7 -0.04 AV7 AVG 15 96910.1 43 COLD 5601P0.69 122 P2 DS1 AV7 +0.00 TEH TEC LAR 21 24 COLD 61OUL

..........................................................................................................

130 83 0.31 94 P5 WAR AV5 -0.17 AV5 AV5 11 96910.1 77 COLD 5601P0.64 127 P2 DSI AV5 +0.04 TEH TEC LAR 20 23 COLD 61OUL0.59 89 PS WAR AV5 +0.17 AV5 AV5 19 96910.1 77 COLD 5601P

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ----------------------------------

130 85 0.66 118 P2 DSI AV2 -0.04 TEH TEC LAR 20 23 COLD 610UL0.40 113 PG WAR AV2 +0.00 AV2 AV3 11 96910.1 42 HOT 5601P0.64 110 P5 WAR AV2 +0.09 AV2 AV3 17 96910.1 42 HOT 5601P0.64 11 P5 WAR AV3 -0.02 AV2 AV3 17 96910.1 42 HOT 5601P0.66 125 P2 DSI AV3 +0.02 TEH TEC LAR 20 23 COLD 61OUL0.48 I1i P5 WAR AV3 +0.06 AV2 AV3 13 96910.1 42 HOT 5601P

Total Tubes : 39Total Records: 164

Page 19: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 8 of 64

St. Lucie Unit 2 (SL2-18)SG 2A Wear Indications 1-19% TWD at AVB locations

ROW COL VOLTS

25 166 0.2133 6 0.1733 8 0.1333 164 0.22

0.1534 165 0.1336 7 0.1647 142 0.10

47 154 0.120.30

47 160 0.190.19

0.1447 162 0.27

0.1548 7 0.1348 9 0.20

0.200.18

48 35 0.1648 161 0.27

0.510.17

49 10 0.190.180.11

49 160 0.170.20

49 162 0.2650 9 0.25

0.1650 11 0.13

0.190.24

50 153 0.1850 159 0.1750 161 0.1850 163 0.1751 8 0.16

0.1151 10 0.1551 102 0.1651 144 0.1551 154 0.21

0.2751 156 0.17

0.1951 160 0.2151 162 0.19

0.290.240.21

52 9 0.430.240.17

52 11 0.170.18

52 13 0.1452 35 0.21

DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG

116 P2118 P2106 P289 P2126 P2135 P2111 P298 P2125 P2117 P2107 P2110 P281 P2120 P2135 P2135 P2131 P2118 P2102 P2112 P2104 P2115 P2108 P2113 P2130 P2128 P2106 P2120 P2123 P2116 P2135 P298 P291 P2119 P2129 P2112 P2121 P2103 P2126 P280 P294 P2121 P2112 P2134 P2105 P278 P2121 P2119 P2137 P2127 P2116 P289 P2125 P2113 P288 P2124 P2103 P2134 P2124 P2

TWD 7TWD 7TWD 7TWD 8TWD 6TWD 7TWD 6TWD 5TWD 6TWD 13TWD 10TWD 10TWD 8TWD 13TWD 8TWD 5TWD 10TWD 10TWD 10TWD 7TWD 9TWD 15TWD 6TWD 10TWD 9TWD 6TWD 6TWD 7TWD 9TWD 12TWD 9TWD 7TWD 10TWD 12TWD 6TWD 6TWD 9TWD 9TWD 9TWD 6TWD 8TWD 6TWD 7TWD 10TWD 12TWD 9TWD 9TWD 11TWD 10TWD 14TWD 12TWD 11TWD 18TWD 12TWD 9TWD 9TWD 10TWD 6TWD 9

AV7AV2AV2AV2AV7AV7AV2AV6AVGAV3AV8AV2AVIAVGAV3AV3AVGAV3AV2AV3AV7AVGAV2AV2AV7AV3AV7AV2AVGAVG

AV3AVGAV7AV2AV3AV2AVG

AV7AVGAV3AV2AVGAV3AVGAV3AV7AVGAV2AV7AV3AV2AVIAV3AVGAV7AVG

AV7AV2AV3

+0.20-0.29+0.22-0.24+0.20+0.15-0.27+0.20+0.20-0.24-0.18-0.22+0.20+0.18-0.18-0.20+0.18-0.20-0.22+0.33+0.15+0.18-0.20-0.18+0.13-0.20+0.11-0.22+0.18+0.18-0.20+0.18+0.15-0.20+0.22-0.22+0.20-0.31+0.18-0.20-0.18+0.26+0.18+0.15-0.24+0.18+0.15-0.15+0.18

-0.20-0.24-0.29-0.18+0.18+0.18+0.18+0.13-0.20+0.35

TEC TERTEC TENTEC TEETEC TERTEC TENTEC TENTEC TENTEC TENTEC TEETEC TEETEC TENTEC TERTEC TEETEC TERTEC TENTEC TENTEC TENTEC TENTEC TENTEN TECTEC TENTEC TENTEC TENTEC TENTEC TENTEC TERTEC TENTEC TENTEC TEETEC TENTEC TENTEC TEETEC TENTEC TENTEC TENTEC TENTEC TERTEC TEETEC TERTEC TEETEC TEETEE TECTEC TEETEC TEETEC TEETEC TEETEC TEETEC TEETEC TENTEC TEHTEC TEETEC TEETEC TERTEC TEETEC TEETEC TERTEC TEETEC TEETEN TEC

HOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTCOLDHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTCOLDHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTCOLD

PROBE

610UL610U'L

610UL610UL610ULSIoUt61OUL

61OUL61OUL61OUL610UL61OUL61OUL610UL610UL610UL061oUL610ULcloUL610UL610Lt61oUL610UL610UL610Lt610UL610UL610UL610UL1610UL610UL610UL610UL610UL61oUL610UL610UL61001.61cUL61oUL610ULi1oUL

610UL610UL61oUL6100L61OUL610UL61OuL61oUL6IoUL610LTslout61oUL61oUL61oUL610UL610UL61OUL

Page 20: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Rev. 0Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1 SG 2A, Page 9 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CNN IND %TE LOCATION EXT EXT UTIL I OTIL 2 CAL # LEG PROBE

52 121 0.11 108 P2 TWD 6 AV3 +0.15 TEC TEH 36 HOT 610UL152 153 0.14 74 P2 TWD 7 AVG -0.31 TEC TEH 20 HOT 610UL52 161 0.41 128 P2 TWD 13 AVG +0.20 TEC TEH 19 HOT 610UL

0.26 133 P2 TWD 9 AV2 -0.20 TEC TEH 19 HOT 610G L53 8 0.23 120 P2 TWD 10 AV3 -0.24 TEC TEE 59 HOT 610UL

0.20 99 P2 TWD 9 AV2 +0.18 TEC TEH 59 HOT 610UL53 10 0.13 94 P2 TWD 7 AV2 -0.24 TEC TEH 58 HOT 610UL

0.12 88 P2 TWD 7 AV7 +0.09 TEC TEH 58 HOT 61OUL53 34 0.16 117 P2 TWD 7 AV3 -0.15 TEH TEC 12 COLD 610UL

0.15 107 P2 TWD 7 AVG +0.22 TEH TEC 12 COLD 61OUL53 128 0.15 117 P2 TWD 6 AV3 -0.31 TEC TEH 33 HOT 610UL53 142 0.19 121 P2 TWD 5 AVG +0.18 TEC TEH 25 HOT 610UL53 154 0.15 128 P2 TWD 5 AVG +0.15 TEC TEH 21 HOT 610UL

0.28 108 P2 TWD 9 AV3 -0.24 TEC TEH 21 HOT 61UL53 162 0.19 115 P2 TWD 10 AVG +0.20 TEC TEH 18 HOT 610UL54 9 0.28 95 P2 TWD 13 AVG +0.18 TEC TEH 58 HOT 610ULT54 11 0.23 127 P2 TWD 11 AV7 +0.18 TEC TEH 58 HOT 610UL

0.20 137 P2 TWD 10 AVG +0.20 TEC TEH 58 HOT 610UL54 15 0.17 103 P2 TWD 7 AV3 +0.00 TEC TEH 56 HOT 610UL54 45 0.11 106 P2 TWD 5 AV3 +0.22 TEN TEC 15 COLD 610UL54 101 0.15 126 P2 TWD 6 AVG -0.22 TEH TEC 54 COLD 610UL54 109 0.18 124 P2 TWD 7 AV3 +0.00 TEH TEC 59 COLD 610UL54 121 0.13 128 P2 TWD 6 AV3 +0.15 TEC TEH 37 HOT 610UL54 147 0.14 124 P2 TWD 7 AVG +0.18 TEC TEH 22 HOT 610UL54 157 0.13 107 P2 TWD 7 AVG +0.15 TEC TEH 20 HOT 610UL54 159 0.16 117 P2 TWD 6 AV7 +0.15 TEC TEH 19 HOT 610UL

0.16 106 P2 TWD 6 AV2 -0.24 TEC TEH 19 HOT 610UL54 161 0.21 117 P2 TWD 11 AV7 +0.18 TEC TEH 18 HOT 610UL

0.24 78 P2 TWD 12 AV2 +0.20 TEC TEH 18 HOT 610UL0.37 125 P2 TWD 16 AVG +0.20 TEC TEH 18 HOT 610UL

55 10 0.15 11 P2 TWD 8 AV3 -0.22 TEC TEH 58 HOT 61OUL0.30 119 P2 TWD 14 AV2 -0.22 TEC TEH 58 HOT 610UL

55 16 0.13 109 P2 TWD 6 AV2 +0.00 TEC TEH 56 HOT 610UL55 34 0.13 124 P2 TWD 5 AV3 -0.15 TEH TEC 11 COLD 610UL

0.13 135 P2 TWD 5 AVG +0.20 TEH TEC 11 COLD 61OUL55 120 0.19 86 P2 TWD 9 AV3 -0.22 TEC TEH 36 HOT 610UL55 122 0.12 86 P2 TWD 6 AVG -0.22 TEC TEN 34 HOT 610UL55 142 0.21 110 P2 TWD 10 AVG +0.15 TEC TEH 24 HOT 610UL55 154 0.30 129 P2 TWD 13 AV3 -0.26 TEC TEH 20 HOT 610UL55 156 0.17 118 P2 TWD 8 AV7 +0.13 TEC TEH 20 HOT 610UL

0.13 100 P2 TWD 7 AVI +0.15 TEC TEH 20 HOT 61OUL55 158 0.13 112 P2 TWD 7 AVG -0.29 TEC TEH 20 HOT 610ML55 160 0.18 113 P2 TWD 9 AV7 +0.15 TEC TEH 18 HOT 610UL56 9 0.12 136 P2 TWD 7 AV3 -0.22 TEC TEH 58 HOT 610UL56 11 0.16 100 P2 TWD 9 AVG +0.00 TEC TEH 58 HOT 610UL

0.21 132 P2 TWD 11 AV2 -0.29 TEC TEH 58 HOT 61UL56 35 0.20 114 P2 TWD 8 AV3 +0.29 TEH TEC 11 COLD 61UL56 113 0.13 138 P2 TWD 6 AV2 +0.04 TEH TEC 45 COLD 610UL56 123 0.11 137 P2 TWD 5 AVG +0.13 TEC TEH 35 HOT 610UL56 147 0.20 94 P2 TWD 6 AVG -0.26 TEC TEH 23 HOT 610UL56 153 0.15 76 P2 TWD 8 AV3 +0.20 TEC TEH 20 HOT 61001,56 159 0.23 120 P2 TWD 12 AV7 +0.15 TEC TEH 18 HOT 610UL

0.21 113 P2 TWD 11 AV2 -0.15 TEC TEH 18 HOT 610UL356 161 0.76 110 P2 TWD 19 AVG -0.33 TEC TEH 19 HOT 610UL

0.20 140 P2 TWD 7 AVG +0.20 TEC TEH 19 HOT 610UL57 10 0.13 123 P2 TWD 7 AV3 -0.20 TEC TEH 58 HOT 610UL

0.16 103 P2 TWD 9 AVG +0.18 TEC TEH 58 HOT 610UL0.18 85 P2 TWD 9 AV2 -0.22 TEC TEH 58 HOT 610UL

57 14 0.14 139 P2 TWD 6 AVG +0.11 TEC TEH 57 HOT 61UL57 20 0.18 129 P2 TWD 7 AV3 -0.24 TEC TEH 55 HOT 610UL57 44 0.14 84 P2 TWD 5 AV3 -0.20 TEH TEC 16 COLD 610UL57 100 0.13 112 P2 TWD 5 AVG +0.20 TEH TEC 53 COLD 61UL57 102 0.21 127 P2 TWD 8 AVG +0.22 TEH TEC 54 COLD 61OUL

Page 21: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure I

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 10 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

57 108 0.1257 116 0.2257 120 0.1557 142 0.1757 154 0.3757 156 0.2457 160 0.20

0.140.19

58 11 0.170.280.300.15

58 17 0.140.12

58 35 0.120.10

58 117 0.1558 127 0.1358 159 0.2659 10 0.27

0.2359 12 0.16

0.230.16

59 14 0.1459 20 0.1659 102 0.23

0.1659 108 0.1459 120 0.1559 148 0.1859 154 0.2359 156 0.24

0.1859 158 0.1559 160 0.4360 11 0.20

0.300.19

60 13 0.1660 17 0.1360 109 0.1960 153 0.1660 157 0.2660 159 0.19

0.2561 10 0.14

0.1861 12 0.1561 14 0.15

0.180.150.140.13

61 34 0.180.11

61 44 0.1461 102 0.2361 104 0.1761 108 0.1661 112 0.17

DEG CHN

83 P292 P2106 P2102 P2125 P299 P276 P2107 P273 P292 P2110 P2121 P236 P2136 P294 P2117 P2119 P255 P2132 P295 P2122 P2114 P263 P2117 P288 P294 P2126 P2109 P2110 P2139 P250 P2125 P2103 P2126 P2133 P292 P2118 P2108 P2115 P2122 P2154 P264 P2123 P277 P2102 P2133 P2113 P2129 P297 P2

P2143 P2143 P2133 P2123 P2130 P2113 P2126 P2130 P2121 P2118 P2135 P2135 P2

IND %TW LOCATION

TWD 5 AV6 +0.18TWD 10 AVG -0.07TWD 7 AV3 -0.24TWD 8 AV6 +0.22TWD 12 AV3 -0.20TWD 8 AV7 +0.13TWD 7 AV7 +0.18TWD 5 AV6 +0.18TWD 7 AV2 -0.22TWD 9 AVI -0.22TWD 13 AV2 -0.22TWD 14 AV6 +0.20TWD 8 AV8 -0.18TWD 6 AV3 -0.22TWD 5 AV2 -0.20TWD 6 AV3 +0.24TWD 5 AV6 -0.20TWD 7 AV2 -0.09TWO 5 AVG -0.02TW1D 9 AV3 +0.22TWD 13 AV3 -0.20TWD 11 AV2 -0.24TWD 8 AV7 +0.00TWD 11 AV3 +0.26TWD 9 AVI +0.15TWD 6 AVG +0.15TWD 8 AV3 -0.22TWD 8 AV6 +0.22TWD 6 AV3 +0.00TWD 6 AV3 +0.09TWD 8 AV3 -0.26TWD 8 AVG -0.04TWD 11 AV3 -0.22TWD 11 AV7 +0.13TWD 9 AVG +0.15TWD 8 AVG -0.27TWD 18 AVG -0.29TWD 10 AV2 -0.22TWO 14 AVG +0.15TWD 10 AV7 +0.18TWD 6 AV2 +0.00TWD 6 AV2 -0.22TWD 7 AV3 +0.00TWD 8 AVG -0.26TWD 9 AV7 -0.07TWD 10 AVG +0.15TWD 12 AVI -0.27TWD 8 AVG +0.15TWD 10 AV3 -0.15TWD 8 AV3 +0.29TWD 6 AV8 -0.07TWD 7 AV7 +0.00TWD 6 AVG +0.00TWD 6 AV3 +0.00TWD 5 AV2 -0.24TWD 8 AV3 -0.13TWD 5 AVG +0.22TWD 5 AV3 -0.18TWD 8 AVG +0.24TWD 7 AVG +0.00TWD 6 AVG +0.00TWD 7 AV3 +0.00

EXT EXT UTIL 1 UTIL 2

TEH TECTEC TEHTEC TEHTEH TECTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TENTEC TEHTEC TEETEC TEHTEH TECTEH TECTEC TEETEC TEETEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEH TECTEH TECTEH TECTEC TEETEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEETEC TEHTEC TEHTEC TEHTEH TECTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

CAL #

6040373921211919195858585857571212403319585858585856545353593622202020201858585857566020211818585858575757575712121654566062

LEG

COLDHOTHOTCOLDHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTCOLDCOLDHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTCOLDCOLDCOLDHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTCOLDHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL61OUL610U1L610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610ULT610UL610LTL610UL610UL610UL610ULL610UL610UL610UL610UL610UL610UL610T1L610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61OUL610U1610UL610UL61OUL610UL610UL61OULT61OUL610UL61OUL610UL610UL610UL610UL610UL610UL610UL610TUL610UL610UL610UL610UL610UL

Page 22: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 11 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

61 116 0.190.150.31

61 126 0.1461 142 0.2261 156 0.21

0.2961 158 0.24

0.240.20

62 11 0.380.220.120.190.20

62 13 0.180.16

62 105 0.1362 109 0.1962 111 0.1362 121 0.1462 139 0.1062 153 0.2062 157 0.15

0.150.14

62 159 0.310.22

63 12 0.220.18

63 18 0.1763 34 0.1463 98 0.2663 102 0.2363 110 0.22

0.0963 114 0.2363 136 0.0963 156 0.23

0.310.350.26

63 158 0.130.220.370.130.22

64 11 0.1864 13 0.16

0.2164 55 0.1264 93 0.1464 101 0.16

0.200.16

64 10S 0.2564 111 0.2164 113 0.1664 115 0.2464 119 0.2264 153 0.12

0.16

DEG CHN

104 P2104 P2111 P2115 P2116 P277 P2110 P2107 P2108 P2131 P2106 P286 P299 P289 P297 P2115 P2134 P2144 P2128 P2117 P2129 P262 P2119 P275 P2116 P274 P2124 P294 P293 P293 P282 P2135 P2151 P2115 P2123 P2122 P2110 P2101 P2118 P2110 P2119 P2121 P2120 P2111 P2104 P2120 P3111 P3119 P284 P2134 P2127 P2143 P2133 P298 P288 P299 P2112 P2133 P2115 P2126 P2121 P2146 P2

IND %TW

TWD 9TWO 8TWD 14TWDO5TWO 8TWO 7TWO 10TWD 8TWO 8TWO 7TWD 17TKW 11TWO 7

TWD 10TWD 10TWO 8TWD 7TWDO5TWD 8TWDO5TWD 6TWDO5TWO 7TWD 8TWO 8TWO 7TWO 10TWO 8TWO 11TWO 9TWD 7TWD 6TWD 8TWO 8TWO 8TWO 4TWO 11TWD 5TWD 11TWO 14TWO 15TWD 12TWD 7TWO 10TWD 16TWD 10TWD 15TWO 9

TWO 7TWO 8TWDO5TWD 6

TWD 6TWD 7TWO 6TWD 9TWO 8TWD 7TWD 11TWD 9

TWO 6TWD 8

LOCATION EXT EXT

AV2 +0.00 TEC TEHAV3 +0.00 TEC TEHAVE -0.07 TEC TEHAV3 +0.00 TEC TEHAVE +0.00 TEH TECAV8 -0.24 TEC TEHAV7 +0.20 TEC TEHAV7 +0.16 TEC TEHAV3 +0.27 TEC TEHAV2 -0.20 TEC TEHAV7 +0.13 TEC TEHAVE +0.20 TEC TEHAVG -0.29 TEC TEHAV2 +0.20 TEC TEHAVI -0.26 TEC TEHAVE +0.15 TEC TEHAV3 -0.24 TEC TEHAVE +0.30 TEH TECAV3 +0.09 TEH TECAVE +0.13 TEH TECAVE -0.13 TEC TEHAV2 -0.24 TEC TEHAVE +0.18 TEC TEHAV8 +0.18 TEC TEHAV7 +0.15 TEC TEHAVI -0.24 TEC TEHAV2 +0.18 TEC TEHAVI -0.24 TEC TEHAV2 +0.00 TEC TEEAVI +0.00 TEC TEHAV3 +0.00 TEC TEHAVE +0.24 TEH TECAV3 -0.02 TEH TECAVG +0.20 TEH TECAVE +0.00 TEH TECAV7 +0.00 TEH TECAVE +0.00 TEC TEHAV7 +0.18 TEC TENAV8 -0.26 TEC TEHAV7 +0.18 TEC TEHAVE +0.15 TEC TEHAVI -0.22 TEC TEHAV7 +0.11 TEC TEHAV6 -0.29 TEC TEHAV2 +0.18 TEC TEHAV7 +0.11 TEC TEHAVG -0.29 TEC TEHAV6 +0.00 TEC TEHAVE -0.29 TEC TEHAV3 +0.00 TEC TEHAV3 -0.11 TEH TECAV6 +0.00 TEH TECAV7 +0.00 TEH TECAVE +0.00 TEH TECAV3 +0.00 TEH TECAVE +0.04 TEH TECAVE -0.22 TEH TECAVE +0.24 TEH TECAV3 +0.00 TEC TEHAV3 +0.00 TEC TEHAVE +0.18 TEC TEHAV3 -0.07 TEC TEH

UTIL 1 UTIL 2 CAL #

4040403340212121212158585858585656555959372721202020191958585611

505360604126202020202020

202020585757154853535356604541372020

LEG

HOTHOTHOTHOTCOLDHOTHOTHOTHOTHOTHOTNOTHOTHOTHOTHOTHOTCOLDCOLDCOLDHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTCOLDCOLDCOLDCOLDCOLDHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDHOTHOTHOTHOT

PROBE

610UL610UL61OUL61OUL610UL610UL61OUL61OUL610UL61OUL6O1UL6107UL610UL610UL6101,UL610UL610ULT610UL3610UL610UL610UL610UL610L3610UL6101L610UL610UL61OUL610UL61OUL610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6101L361013161013-,6101UL610UL610UL610UL61OUL61OUL61OUL6101,L610UL610L3610UL610UL610,UL610UL61OUL

Page 23: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 12 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

65 12 0.260.260.320.12

65 14 0.190.280.230.15

65 34 0.1065 94 0.1565 96 0.2065 98 0.2265 100 0.1565 102 0.1965 106 0.13

0.1865 108 0.29

0.1565 110 0.18

0.1765 112 0.13

0.220.12

65 116 0.230.48

65 156 0.220.17

65 158 0.2266 13 0.25

0.1566 15 0.1566 43 0.1366 99 0.14

0.310.16

66 101 0.1466 103 0.1866 105 0.2266 107 0.2366 I1i 0.24

0.280.13

66 113 0.230.22

66 115 0.1966 117 0.1866 145 0.14

0.1566 153 0.2166 155 0.13

0.2066 157 0.14

0.270.17

67 76 0.2067 96 0.13

0.1567 100 0.2767 102 0.24

0.2567 104 0.18

0.210.16

DEG CHN

112 P2119 P2105 P271 P2130 P2123 P2142 P290 P2132 P2124 P2142 P2129 P2105 P2129 P2138 P2136 P2129 P2131 P2117 P2140 P2143 P2121 P2122 P2123 P2117 P2103 P2100 P2119 P2115 P255 P261 P2125 P2136 P2119 P298 P2117 P2137 P2148 P2109 P2109 P211 P2137 P276 P2104 P269 P297 P2142 P260 P2132 P2118 P2108 P2102 P2119 P2105 P2129 P2149 P2150 P2124 P2108 P2119 P2151 P2149 P2134 P2

IND %TW

TWD 13TWO 13TWD 15TWD 7TWO 8TWO 10TWO 9TWO 6TWDO5

TWO 6TWO 7TwO 8TWO 6TWO 7TWD 5TWO 7TWO 10TWO 6TWD 7TWO 7TWO 5TWO 9TWDO5TWO 11TWO 18TWO 8TWO 6TWO 8TWD 10

TWO 6TWO 7TWDO5TWO 6

TWO 11TWO 6TWDO5TWO 7TWO 8TWO 9TWO 9TWD 11TWDO5TWO 9TWO 9TWO 9TWO 9TWO 7TWO 7TWD 7

TWO 7TWO 10TWO 7TWD 12TWO 8

TWO 8TWDO5TWO 6TWD 7TWD 9TWO 9TWO 7TWD 8TWO 6

LOCATION

AV6 -0.31AV3 +0.26AV2 +0.22AVI -0.20AV6 +0.00AV3 +0.00AV2 +0.00AVI +0.00AV6 +0.20AVG +0.00AV3 +0.00AV6 +0.20AV6 +0.17AVG +0.22AV3 +0.02AV7 +0.04AV6 +0.00AV3 +0.00AV6 +0.04AV7 +0.06AV7 +0.00AVG +0.22AV2 -0.15AV3 -0.02AVG -0.04AV8 -0.27AVG -0.27AVG -0.27AVG +0.00AVl +0.15AVi +0.00AVG -0.11AV7 +0.11

AVG +0.00AV3 +0.09AVG -0.28AVG -0.26AV3 +0.00AV3 +0.00AV2 +0.02AV3 +0.02AVG +0.28AV3 +0.11AVG +0.02AV3 +0.00AVG -0.02AVI +0.02AV8 -0.11AVG +0.18AV8 -0.24AVI +0.18AV8 +0.18AV3 +0.20AVI -0.27AV3 +0.00AV7 +0.00AV3 +0.00AVG +0.17AVG +0.20AV3 +0.00AV2 +0.00AV3 +0.00AVG +0.28

EXT EXT

TEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TWCTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEC TENTEC TEHTEC TEHTEC TEHTEC TENTEC TENTEC TENTEC TEHTEC TEHTEC TEHTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

UTIL I UTIL 2 CAL #

5858585857575757

1248485153545858606059596262624040212121565656165151

51545555575959594444414022222120

20202020274949525353555555

LEG

HOTHOTHOTHOTHOTHOTHOTHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD1HOTHOTHOTHOTHOT

.HOTHOTHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCODCOLDHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

6101TL6100LT610UL0610UL

6100UL610UL46100UL61001.GlOut610UL61 OUL610UL61oUL610LT610UL610UL61OUL61oUL610UL61oUL610LT610UL061oUL61oUL610UL610UL610ULL6 10ULT

61OUL61oUL61oUL61oUL61oUL610UL610UL610UL6 10 UL6 10UL,610ML610UL610UL610UL610UL610ULT610ULT610UL610UL610UL610UL6 10UL610UL610UL610UJL610UL6 10UL61OUL610UL610UL610UL610UL610UL610UL610UL61oUL

61 out61 out

Page 24: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 13 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN

67 108 0.150.21

67 110 0.150.230.19

67 112 0.140.220.14

67 122 0.1267 140 0.0967 142 0.13

0.110.17

67 152 0.1667 154 '0.1767 156 0.12

0.160.12

67 158 0.110.12

68 13 0.180.13

68 17 0.1368 55 0.1368 63 0.14

0.1768 67 0.1968 75 0.20

0.280.27

68 89 0.1768 99 0.27

0.2268 101 0.19

0.2068 103 0.16

0.2168 105 0.15

0.2268 107 0.1268 109 0.14

0.1568 111 0.14

0.320.12

68 113 0.120.15

68 115 0.200.330.22

68 153 0.200.160.19

68 155 0.430.360.200.420.20

68 157 0.190.270.320.250.24

125 P2140 P2114 P2105 P2121 P2136 P2147 P2125 P2117 P2128 P2106 P2119 P2114 P285 P2100 P253 P277 P2100 P2124 P294 P2132 P2105 P273 P2141 P2119 P2133 P2

141 P2130 P2118 P2121 P2120 P2150 P2161 P2117 P2119 P2126 P2122 P290 P298 P2117 P2118 P2137 P2105 P2120 P2124 P299 P2134 P2117 P2112 P2140 P2114 P2106 P298 P2114 P2127 P2100 P2129 P2146 P297 P298 P2115 P2110 P2131 P2

IND %TW

TWD 6TWD 8TWD 6TWD 9TWD 7TWD 6TWD 8TWD 6TWD 6TWD 4TWD 6TwD 6TWD 8TWD 8TWD 9TWD 6TWD 8TND 6TWD 6TWD 6TWD 7TWD 5TWD 6TWD 5TWD 6TWD 7TWD 8TWD 8TWD 11TWD 10TWD 6TWD 8TWD 7TWD 7TWD 8TWD 7TWD 8TED 6TWD 9TWD 5TWD 6TWD 6TWD 6TWN] 11TWD 5TWD 5TWD 7TWD 10TN] 14TWD 10

TWD 10TWD 8TWD 9TWD 13T I] 11

TWD 7T•ND 13TWD 7TWD 7TWD 9TWD 11TWD 8TWD 8

LOCATION

AV2 +0.09AV3 +0.09AV2 +0.00AV3 +0.00AV6 +0.00AVG +0.09AV2 +0.00AV3 +0.00AV6 +0.22AVG +0.11

AV8 -0.22AVG +0.18AV2 -0.02AVI +0.15AVI +0.18AV8 -0.24AVG -0.29AV2 +0.18AV7 +0.11AVI -0.27AVG -0.29AVi +0.00AV2 +0.00AV3 -0.15AV3 +0.00AV7 +0.09AVG +0.07AV2 +0.00AV3 +0.00AVG +0.00AV3 -0.09AVG +0.00AV3 +0.00AV2 +0.04AVG +0.07AV7 +0.02AV3 -0.09AVG +0.22AV3 +0.00AVG +0.07AV7 +0.00AVG +0.00AV3 +0.00AVG +0.00AV7 +0.00AV2 +0.09AV7 +0.04AV7 +0.00AVG +0.00AV3 +0.00AVG +0.18AV3 +0.18AVI +0.11AV8 -0.18AV7 -0.22AVG -0.27AV3 +0.02AVI -0.07AV8 +0.16AV7 -0.29AVG -0.31AV3 +0.20AVi -0.16

EXT EXT

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TENTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEH

UTIL I UTIL 2 CAL #

595960606061616134242424242020

20202020205757561520202228282847so

LAR 5o535356565656586060606060454541414120202021212121212121212121

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOT

PROBE

61DUL610UL610UL610UL610UL610UL610UL610UL610 LT610LTL6100L610UL610UL610UL610UL610OUL.610UL610UL610UL6101L3610UL61OUL610UL610L3610UL610UL610UL610UL61013L6101L36101L36101.61013L610UL610UL610UL610UL610UL610UL610UL6101.6101L361OUL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL61CUL61OUL61OUL610UL610UL61OUL

Page 25: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 14 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

69 14 0.210.19

69 56 0.2269 76 0.2069 88 0.1869 94 0.1869 96 0.2069 98 0.14

0.230.22

69 100 0.260.19

69 104 0.210.180.16

.69 106 0.130.15

69 108 0.190.240.31

69 112 0.1269 114 0.1369 124 0.1569 152 0.2669 154 0.25

0.220.22

69 156 0.200.360.18

70 15 0.2670 17 0.2070 91 0.18

0.190.15

70 95 0.140.21

70 97 0.360.24

70 105 0.230.360.18

70 109 0.1570 117 0.1870 123 0.40

0.1871 14 0.17

0.2171 18 0.1471 74 0.1671 76 0.23

0.1971 78 0.1571 96 0.14

0.150.30

71 98 0.240.26

71 102 0.260.320.17

71 104 0.1571 108 0.28

DEG CHN

108 P2102 P2133 P2125 P2135 P2132 P2147 P2120 P2133 P2134 P2110 P2124 P2122 P2122 P2107 P2116 P2120 P2128 P2126 P2116 P2103 P2103 P2128 P2100 P2136 P2124 P2101 P2117 P2114 P2136 P2124 P2112 P2127 P2139 P2131 P286 P2147 P2142 P2157 P2142 P2140 P2156 P2Il1 P2103 P2125 P2117 P2102 P2105 P2124 P2129 P2131 P2137 P2148 P2151 P2142 P2133 P2155 P2122 P2106 P2127 P2110 P2107 P2135 P2

IND %TW LOCATION EXT EXT UTIL 1 UTIL 2

TWD 8 AV3 +0.15 TEC TEETWD 7 AV2 +0.07 TEC TEETWD 8 AV2 +0.09 TEE TECTWD 8 AV6 +0.00 TEH TECTWD 6 AV6 +0.00 TEE TECTED 7 AVG +0.00 TEE TECTED 7 AV3 +0.22 TER TECTWD 5 AVG +0.07 TEE TECTWD 9 AV3 +0.00 TEE TECTWD 8 AV2 +0.00 TEH TECTWD 9 AV3 +0.00 TEE TECTWD 7 AV7 +0.00 TEE TECTWD 8 AV6 +0.00 TEE TECTWD 7 AV2 +0.00 TEE TECTWD 7 AV7 +0.00 TER TECTWD 5 AVG +0.04 TEE TECTED6 AV7 +0.04 TER TECTED 7 AV7 +0.00 TEE TECTWD 9 AVG +0.00 TEE TECTWD 11 AV3 +0.00 TEE TECTWD 5 AVG +0.17 TEE TECTWD 7 AVE +0.00 TEC TEETWD 7 AV3 -0.02 TEC TEETWD 9 AVG -0.29 TEC TEETED 8 AV3 +0.02 TEC TEETWD 8 AV2 +0.00 TEC TEETWD 8 AVI +0.15 TEC TEETWD 7 AV8 +0.18 TEC TEETWD 12 AVG -0.27 TEC TEETWD 6 AV3 +0.27 TEC TEETWD 11 AV7 +0.00 TEC TEHTWD 8 AV2 +0.00 TEC TEETWD 6 AV7 -0.07 TEE TECTWD 7 AV3 +0.00 TEE TECTWD 5 AV2 +0.00 TEE TECTWD 5 AV3 +0.24 TEE TECTWD 8 AV2 +0.00 TEE TECTWD 10 AV3 +0.02 TEE TECTWD 7 AVG +0.04 TEE TECTWD 9 AV2 +0.00 TEE TECTWD 12 AV3 +0.00 TEE TECTWD 7 AV8 +0.00 TEE TECTWD 6 AV8 +0.09 TEH TECTWD 9 AV2 +0.04 TEC TEETWD 16 AVG +0.07 TEC TEETED 9 AV3 +0.00 TEC TEETWD 7 AV3 +0.00 TEC TEETWD 9 AV2 +0.00 TEC TEETWD 6 AV4 +0.26 TEC TEETWD 7 AV4 +0.26 TEE TECTWD 9 AVG +0.00 TEE TECTWD 8 AV7 +0.00 TEE TECTWD 6 AV3 +0.00 TEE TECTWD 5 AV7 +0.00 TEE TECTWD 6 AVE +0.00 TEE TECTWD 11 AV2 +0.00 TEE TECTWD 7 AV3 +0.00 TER TECTED 8 AV5 +0.00 TEH TECTWD 9 AV3 +0.00 TEE TECTED 11 AV2 +0.00 TEE TECTWD 7 AVI +0.00 TEE TECTWD 6 AVG +0.26 TEE TECTED 11 AV3 +0.00 TEE TEC

CAL #

57571628474848515151535356565658586O60606241352121212121212156574747474949505055555559403434565656282727254949495os05353535559

LEG

HOTHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDHOTHOTHOTHOTHOTHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001,610UL610UL610UL610UL61OUL610UL61OUL610UL610UL61OUL610UL610UL610UL610UL610UL61ULG6OUL610UL610UL610UL610UL610UL610UL610UL61OUL610UL6100,L6101L.610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

Page 26: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 15 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG

71 116 0.15 1010.19 1050.16 106

71 152 0.15 920.12 105

72 15 0.15 10472 75 0.17 137

0.16 1230.20 1080.14 109

72 79 0.20 1300.20 116

72 89 0.13 1390.13 104

72 91 0.16 1430.14 1280.29 1290.15 1120.12 129

72 93 0.24 12972 95 0.13 130

0.15 14172 97 0.18 12972 101 0.20 13172 103 0.24 116

0.13 110

0.16 1200.23 1170.29 103

72 105 0.40 1050.15 122

72 107 0.19 12672 109 0.18 122

0.18 1310.24 1170.31 1380.13 133

72 117 0.23 12572 151 0.15 12372 153 0.21 9273 18 0.26 137

0.26 12973 74 0.21 13973 76 0.16 128

0.30 11973 86 0.14 135

0.11 13573 88 0.16 134

0.17 1400.17 1340.13 123

73 92 0.17 1170.15 1290.14 139

73 94 0.15 1350.16 1420.16 127

73 96 0.19 1380.20 120

73 98 0.22 1320.18 90

73 100 0.28 1220.42 118

CHN IND %TW

P2 TWD 8P2 TWD 9P2 TWD 8P2 TWD 8P2 TWD 6P2 TWD 6P2 TWND 7P2 TWD 7P2 TWD 8P2 TWD 6P2 TWD 8P2 TWD 8P2 TWD 5P2 TWD 5P2 TWD 6P2 TWD 5P2 TWD 10P2 TWD 5P2 TWD 5P2 TWD 9P2 TWD 5P2 TWD 6P2 TWD 7P2 TWD 7P2 TWD 9P2 TWD 5P2 TWD 6P2 TWD 9P2 TWD 11P2 TWD 14P2 TWD 6P2 TWD 8P2 TWD 7P2 TWD 7P2 TWD 9P2 TWD 11P2 TWD 5P2 TWD 11P2 TWD 5P2 TWD 10P2 TWD 9P2 TWD 9P2 TWD 9P2 TWD 7P2 TWD 11P2 TWD 6P2 TWD 5P2 TWD 6P2 TWD 6P2 TWD 6P2 TWD 5P2 TWD 7P2 TWD 6P2 TWO 6P2 TWD 6P2 TWD 6P2 TWD 6P2 TWD 7P2 TWD 7P2 TWD 8P2 TWD 7P2 TWD 10P2 TWD 14

LOCATION

AVi +0.02AV2 +0.00AV3 +0.00AV8 -0.22AVG -0.24AV3 +0.18AVG +0.00AV7 +0.00AV8 +0.00AV3 +0.00AV2 +0.00AV8 +0.02AVG +0.11AV3 -0.07AVg +0.00AVG +0.07AV3 +0.00AV2 +0.00AV7 +0.00AV3 +0.00AV4 +0.00AVG +0.00AV2 +0.00AVG +0.00AV8 -0.04AV7 +0.00AVG +0.15AV5 -0.07AV3 +0.04AV3 +0.00AV2 +0.00AVG +0.04AV2 -0.02AV3 +0.00AVS +0.00AVG -0.20AV7 +0.00AV2 -0.04AV3 -0.20AVI -0.22AVI -0.04AV4 +0.18AV4 +0.00AVi +0.00AV3 +0.00AV4 +0.00AV2 +0.00AV7 -0.02AVG +0.00AV5 -0.20AV4 +0.18AV4 +0.00AV2 +0.00AVG +0.00AV2 +0.00AVS +0.00AVG +0.00AVG +0.00AV7 +0.00AV2 +0.00AVG +0.24AV3 +0.00AV4 +0.00

EXT EXT UTIL I

TEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTER TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

UTIL 2 CAL #

404040202057282828282626474747474747474848485153565656565656565860606060604021205757272828454547474747484848484848484851515353

LEG

HOTHOTHOTHOTHOTHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDHOTHOTHOTHOTHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL610UL610UL610T1L610UL610UL610UL610UL610UL610UL610UL610UL101UL

610UL610UL610UL610UL610UL610UL1610UL610UL61001.610UL610UL610UL610UL610UL61OUL6101L610UL61OUL610UL610UL610UL610UL610UL610UL610UL6101UL61001.610UL610UL61OUL610UL610UL610UL610UL610UL6100UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

Page 27: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 16 of 64

SG 2A Wear Indications 1-19% TWD at A"1 locations (continued)

ROW COL VOLTS

73 102 0.270.22

73 104 0.290.150.170.230.35

73 106 0.1573 108 0.14

0.300.090.090.190.11

73 112 0.1373 128 0.1474 17 0.23

0.250.22

74 67 0.150.18

74 69 0.1874 71 0.1974 73 0.16

0.2074 75 0.2574 77 0.20

0.220.15

74 81 0.160.11

74 83 0.1474 85 0.17

0.1574 89 0.22

0.260.140.140.260.17

74 91 0.180.14

74 93 0.180.17

74 95 0.350.430.23

74 97 0.340.21

74 99 0.130.120.190.230.13

74 103 0.2674 107 0.1274 109 0.29

0.260.220.22

74 111 0.200.150.16

DEG

13514711411612313111713812812513066128135131120141145134129122142134791081291311301141401381429313412513313611912013713813814114612913014213915592123114116117145114110

125129117129118121

CNN IND %TW

P2 TWD 10P2 TWD 8P2 TWD 11P2 TWD 6P2 TWD 7P2 TWD 9P2 TWD 12P2 TWD 6P2 TWD 6P2 TWD 11P2 TWD 4P2 TWD 4P2 EWD 7P2 TWD 4P2 TWD 6P2 TWD 5P2 TWD 8P2 NWD 9P2 TWD 8P2 TWD 7P2 TWD 8P2 TWD 7P2 TWD 8P2 TWD 7P2 TWD 8P2 TWD 10P2 TWD 8P2 TWD 9P2 TWD 7P2 TWD 7P2 TWD 5P2 TWD 6P2 TWD 7P2 TWD 6P2 TWD 8P2 TWD 9P2 TWD 5P2 TWD 5P2 TWD 9P2 TWD 6P2 TWD 6P2 TWD 5P2 TWD 7P2 TWD 7P2 TWD 12P2 TWD 14P2 TWO 8P2 TWD 10P2 TWD 6P2 TWD 5P2 TWO 5P2 TWD 7P2 TWD 9P2 TWD 5P2 TWD 9P2 TWD 5P2 TWD 11P2 TWD 10P2 TWD 9P2 TWD 9P2 TWD 8P2 TWD 6P2 TWD 6

LOCATION

AV4 +0.00AVE +0.00AV5 -0.31AV4 +0.15AV3 +0.00AV2 +0.00AV6 +0.00AVI +0.02AVS +0.00.AV3 +0.00AV4 +0.00AV2 +0.13AVG -0.09AV7 +0.00AV4 +0.26AV2 +0.00AVI -0.07AV2 +0.15AV6 -0.04AV5 -0.11AV6 +0.02AV4 +0.04AV7 +0.02AV2 +0.07AV3 +0.00AV3 +0.00AVE +0.00AV6 +0.00AV7 -0.02AV3 +0.00AV4 +0.15AV3 +0.02AV4 +0.07AV5 +0.04AV7 +0.07AV6 +0.00AV5 +0.02AV4 +0.02AV3 -0.07AV2 -0.02AV7 +0.00AV3 +0.00AV7 +0.00AV3 +0.00AV4 +0.15AV3 +0.00AV2 +0.00AV3 -0.02AV4 +0.30AVG -0.15AV5 -0.11AV3 +0.00AV2 +0.00AVI +0.22AV3 +0.00AV3 +0.00AV5 +0.06AVG +0.09AV7 +0.09AV8 +0.09AV5 +0.02AVG +0.00AV7 +0.00

EXT EXT UTIL 1

TEN TECTEN TECTEE TECTEN TECTEE TECTEN TECTEE TECTEN TECTEN TECTEE TECTEN TECTEN TECTEN TECTEN TECTEE TECTEC TENTEC TEETEC TENTEC TEETEN TECTEN TECTEN TECTEN TECTEE TECTEN TECTEN TECTEN TECTEN TECTEE TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEE TECTEN TECTEN TECTEN TECTEN TECTEN TECTEE TECTEN TECTEE TECTEE TECTEE TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEE TECTEN TECTEN TECTEN TECTEN TEC

UTIL 2 CAL #

545456565656565860606060606062335757572121233029292727272725252323234747474747474747494949494950s05151515151555759595959595959

LEG PROBE

COLD 61OULCOLD 61SULCOLD 610ULCOLD 610ULCOLD 610ULCOLD 61OULCOLD 61OULCOLD 61OULCOLD 610ULCOLD 61OULCOLD 61OULCOLD 61OULCOLD 610ULCOLD 61 OULCOLD 61OULHOT 61OULHOT 61OULHOT 61OULHOT '610ULCOLD 61OULCOLD 61OULCOLD 61OULCOLD 610ULCOLD 610ULCOLD 610ULCOLD 610ULCOLD 61OULCOLD 61OULCOLD 61OULCOLD 61OULCOLD 610ULCOLD 61OULCOLD lO1ULCOLD S1OUL

COLD 610ULCOLD S61OULCOLD 61OULCOLD 61OULCOLD 61OULCOLD 61OULCOLD 61OULCOLD 6100LCOLD 610ULCOLD 610ULCOLD 61OULCOLD 61OULCOLD 610ULCOLD 61OULCOLD 61OULCOLD 6100LCOLD 61OULCOLD 61OULCOLD 610ULCOLD 610ULCOLD 610ULCOLD 610ULCOLD 610ULCOLD 610ULCOLD 61OULCOLD 61OULCOLD 610ULCOLD 610ULCOLD 610UL

Page 28: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 17 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN

74 117 0.1674 139 0.1474 153 0.16

0.220.16

75 18 0.150.220.19

75 56 0.1375 72 0.16

0.150.15

75 76 0.150.240.22

75 78 0.150.16

75 84 0.1775 86 0.21

0.200.24

75 90 0.160.13

75 92 0.190.24

75 94 0.160.170.190.23

75 96 0.230.160.19

75 98 0.440.230.30

75 100 0.260.27

75 102 0.230.400.370.120.14

75 104 0.350.190.150.210.37

75 106 0.110.130.17

75 108 0.320.210.17

75 110 0.2275 118 0.1675 140 0.12

0.1575 142 0.1175 146 0.1275 152 0.1475 154 0.14

0.1376 17 0.13

109 P2121 P264 P2121 P2127 P2136 P2113 P2106 P286 P288 P2124 P283 P2130 P2131 P2118 P2141 P2126 P2126 P2114 P2126 P2111 P2129 P288 P2139 P2115 P2141 P2143 P2130 P2143 P2140 P2132 P2129 P2146 P2151 P2140 P2136 P2145 P2112 P2115 P2123 P2105 P2136 P2144 P2148 P2127 P2139 P2142 P2126 P2136 P2133 P2109 P2136 P2113 P2109 P295 P2140 P279 P2125 P284 P2101 P211 P296 P246 P2

IND %TW

TWO 8TWO 6

TWO 6TWO 8TWO 6TWD 7TWO 9TWO 8

TWO 5TWO 7

TWO 6TWO 6TWD 6TWO 10TWO 9TWO 7TWO 7TWD 7TWO 8TWO 8TWO 9TWO 6

TWDO5TWO 7TWD 9TWO 6TWO 7TWO 7TWO 9TWO 9TWO 6TWO 7TWO 12TWO 7TWO 9TWO 8TWO 8TWD 8TWO 13TWO 12TWD 5TWDO5TWO 12TWO 7TWO 6TWO 8TWO 12TWO 4TWDO5TWO 7

TWO 12TWO 8TWO 7

TWO 8TWO 8TWO 6TWO 7TWO 6TWO 6

TWO 7TWO 7TWO 7TWO 6

LOCATION

AV2 -0.09AV2 +0.00AV8 -0.15AVI -0.27AV5 -0.15AVE +0.00AV4 +0.00AV2 +0.00AV4 +0.22AV4 +0.02AV5 -0.11AVE +0.00AV3 +0.00AV4 +0.00AV5 +0.00AV3 +0.00AV5 +0.00AV3 +0.02AV7 +0.00AV4 +0.00AV3 +0.00AV5 +0.04AV2 -0.22AVG +0.00AV4 +0.17AV3 -0.02AVE +0.00AV5 +0.00AV4 +0.00AVE +0.00AVS +0.00AV4 +0.00AV2 +0.00AV4 +0.00AV5 +0.00AV4 +0.15AVG +0.02AVE +0.00AV5 +0.00AV4 +0.20AV3 -0.17AV2 +0.17AV2 +0.00AV3 +0.00AV4 +0.00AV5 -0.22AVE +0.00AV4 +0.28AV5 +0.04AVE +0.26AV3 +0.04AV4 +0.02AVS -0.11AV4 +0.00AV4 +0.15AVE +0.18AVS -0.26AV3 -0.26AV5 +0.00AVI -0.22AVI -0.27AVB +0.18AV2 +0.00

EXT EXT

TEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TENTEC TEHTEC TEHTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEO TECTEH TECTEH TEOTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEO TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEN TECTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEHTEC TEH

UTIL 1 UTIL 2 CAL #

40272121215656561529292927272725252344444447474949494949494949495o5o5o52525353535353555555555557575759595960

3824242422202020

56

LEG

HOTHOTHOTHOTHOTHOTHOTHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDHOTHOTHOTHOTHOTHOTHOTHOTHOT

PROBE

61001.610UL610UL6101UL610UL610LT1610UL610UL6103L610UL610UL610UL610UL610UL610UL6100UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001.610UL610UL610UL610UL610UL610UL61001.61001.610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001.610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL

Page 29: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 18 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

76 31 0.1376 33 0.1276 67 0.1876 69 0.1376 71 0.21

0.2276 75 0.26

0.250.190.280.18

76 77 0,170.14

0.1176 79 0.1676 81 0.17

0.200.17

0.1676 85 0.18

0.40

0.1576 87 0.12

0.1776 89 0.16

0.180.180.330.29

76 91 0.140.230.130.180.180.13

76 93 0.150.280.17

76 95 0.310.25

76 97 0.140.230.18

76 99 0.240.24

76 101 0.1576 103 0.18

0.140.150.180.52

76 105 0.150.25

76 109 0.190.280.280.170.14

76 115 0.1876 121 0.1476 147 0.1776 153 0.15

0.13

DEG CHN

113 P2129 P2112 P2128 P288 P298 P2122 P2107 P2106 P2127 P2130 P2125 P2125 P2102 P2133 P2114 P2110 P2120 P2117 P2114 P2120 P2130 P290 P2113 P2139 P2101 P2118 P2117 P2105 P286 P2120 P2115 P2112 P2129 P2135 P2135 P2130 P2113 P2128 P2132 P299 P2112 P2117 P2145 P2161 P2116 P2131 P2117 P297 P281 P2112 P286 P2124 P2128 P2127 P2126 P2126 P290 P2III P290 P2122 P2100 P2131 P2

IND %TW LOCATION EXT EXT

TWD 6 AV4 +0.22 TEH TECTWD 6 AV4 +0.18 TEH TECTWD 7 AV5 -0.09 TEH TECTWD 6 AV4 +0.04 TEH TECTWD 8 AV3 +0.00 TEH TECTWD 9 AV4 +0.00 TEH TECTWD 10 AV2 +0.00 TEH TECTWD 10 AV3 -0.11 TEH TECTWD 8 AV4 +0.02 TEH TECTWD 11 AVS -0.15 TEH TECTWD 7 AV6 -0.11 TEH TECTWD 7 AV4 +0.00 TEH TECTWD 6 AV7 +0.00 TEH TECTWD 5 AV5 -0.20 TEH TECTWD 6 AV4 +0.15 TEH TECTWD 7 AV4 +0.02 TEH TECTWD 8 AVS +0.04 TEH TECTWD 7 AV6 -0.04 TEH TECTWD 7 AV7 +0.07 TEH TECTWD 8 AV3 +0.00 TEH TECTWD 15 AV4 +0.00 TEH TECTWD 7 AV5 -0.11 TEH TECTWD 6 AV4 +0.00 TEH TECTWD 7 AV6 +0.00 TEH TECTWD 6 AV6 +0.00 TEN TECTWD 7 AVS -0.02 TEH TECTWD 7 AV4 +0.07 TEH TECTWD 11 AV3 +0.02 TEH TECTWD 10 AV2 +0.02 TEH TECTWD 5 AV2 +0.00 TEH TECTWD 8 AV3 +0.00 TEH TECTWD 5 AV4 +0.20 TEH TECTWD 6 AVS -0.20 TEH TECTND 6 AV6 +0.00 TEH TECTWD 5 AV7 +0.02 TEH TECTWD 6 AV2 +0.00 TEH TECTWD 10 AV3 +0.00 TEH TECTWD 6 AV5 +0.00 TEH TECTWD 11 AV3 +0.00 TEH TECTWD 9 AV4 +0.00 TEH TECTWD 6 AV6 +0.00 TEH TECTWD 9 AV5 +0.00 TEH TECTWD 7 AV4 +0.17 TEH TECTND 7 AV5 +0.00 TEH TECTWD 7 AV7 -0.13 TEH TECTWD 6 AV3 +0.00 TEH TECTWD 7 AV7 +0.00 TEH TECTWD 6 AV6 -0.20 TEH TECTWD 6 AV5 -0.20 TEH TECTWD 7 AV3 +0.00 TEH TECTWD 17 AV2 +0.00 TEH TECTWD 6 AV4 +0.00 TEH TECTWD 10 AVS +0.02 TEH TECTWD 7 AV7 +0.00 TEH TECTWD 10 AV6 +0.00 TEH TECTWD 10 AV5 +0.00 TEH TECTWD 7 AV4 +0.00 TEH TECTWD 6 AV3 -0.04 TEH TECTWD 9 AV4 +0.22 TEC TEHTWD 7 AV5 -0.20 TEC TEHTWD 5 AVS -0.22 TEC TEHTWD B AV8 -0.22 TEC TEHTWD 7 AV4 +0.15 TEC TEH

UTIL 1 UTIL 2 CAL #

121222242929282828282828282826262626262424244545474747474747474747474748484848485151515050535656565656565660606060604136232020

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDHOTHOTHOTHOTHOT

PROBE

6100LT610UL610UL610UL610UL610UL6100UL610UL6101UL610UL610UL610UL61001.

610UL610UL610UL610UL610UL610UL6100LT610UL610UL610UL610UL610UL610UL610UL61001L610UL6101UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001.610UL610UL610UL610UL610UL610UL610UL610UL610UL6101UL610UL610UL610UL

Page 30: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 19 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

77 18 0.220.280.370.210.24

77 56 0.1377 70 0.17

0.210.20

77 72 0.180.19

77 74 0.260.200.21

77 76 0.190.20

77 78 0.170.150.19

77 80 0.1777 86 0.1177 88 0.1877 90 0.14

0.150.160.210.13

77 92 0.250.350.370.330.290.21

77 94 0.300.230.260.240.320.21

77 96 0.250.120.160.21

77 98 0.150.400.270.110.31

77 100 0.220.14

77 102 0.220.280.21

77 104 0.280.180.160.43

77 106 0.190.160.350.190.17

DEG

14112211715314084130135116123141127105130117121131128131109146126971321171251321291311281221401351261281351311271341271421201391191il

11814112511311314411710211611962116117ill12395121

CHN IND %TW LOCATION

P2 TWD 8 AVi +0.04P2 TWD 10 AV2 +0.35P2 TWD 12 AV4 +0.22P2 TWD 8 AVS -0.07P2 TWD 9 AV6 -0.13P2 TWD 6 AV4 +0.22P2 TWD 7 AV3 +0.09P2 TWD 9 AV4 +0.02P2 TWD 9 AV5 +0.07P2 TWD 7 AV5 +0.00P2 TWD 8 AVE +0.00P2 TWD 10 AV4 +0.00P2 TWD 8 AV5 +0.00P2 TWD 9 AVE +0.00P2 TWD 8 AV4 +0.00P2 TWD 8 AV5 +0.00P2 TWD 7 AV3 +0.00P2 TWD 6 AV4 +0.02P2 TWD 8 AV5 +0.04P2 TWD 7 AV7 +0.02P2 TWD 5 AV7 +0.00P2 TWO 6 AV7 +0.02P2 TWD 5 AV2 +0.00P2 TWD 6 AV3 +0.00P2 TWD 6 AV4 +0.00P2 TWD 7 AV5 +0.09P2 TWD 5 AV7 +0.00P2 TWD 9 AV2 +0.00P2 TWD 12 AV3 +0.00P2 TWD 13 AV4 +0.00P2 TWD 11 AV5 +0.00P2 TWD 10 AVE +0.00P2 TWD 8 AV7 +0.00P2 TWD 11 AV2 +0.00P2 TWD 8 AV3 +0.00P2 TWD 9 AV4 +0.00P2 TWD 9 AV5 +0.00P2 TWD 11 AVG +0.00P2 TWD 8 AV7 +0.00P2 TWD 9 AV2 +0.00P2 TWD 5 AV3 +0.00P2 TWO 6 AVS +0.00P2 TWD 8 AVE +0.00P2 TWD 6 AVE -0.13P2 TWD 13 AV5 +0.00P2 TWD 10 AV4 +0.00P2 TWD 4 AV3 +0.15P2 TWO 11 AV2 +0.00P2 TWD 8 AV3 -0.04P2 TWD 6 AVE +0.17P2 TWD 8 AV4 +0.00P2 TWO 10 AV5 +0.00P2 TWD 8 AVE +0.00P2 TWD 10 AVG +0.00P2 TWD 7 AVS +0.00P2 TWD 6 AV3 +0.31P2 TWD 14 AV2 +0.00P2 TWD 7 AV2 +0.00P2 TWD 7 AV3 -0.02P2 TWD 12 AV4 +0.00P2 TWD 8 AVS +0.04P2 TWD 7 AVG +0.02

EXT EXT

TEC TENTEC TEHTEC TEHTEC TEHTEC TEHTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEN TECTEH TECTEH TECTEH TECTEH TECTEE TECTEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEN TEC

UTIL I UTIL 2 CAL #

575757575731323232303027272728282626262645474747474747484848484848484848484848484848485151515151535354545456

5656565858585858

LEG

HOTHOTHOTHOTHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL61OUL610UL

610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL610UL610ULT6 10UL610ULT610UL610UL610UL610UL6 10UL610UL610UL610UL610UL610UL610UL610UL61OULT610UL610UL610UL610UL610UL610UL610UL610UL610UL610ML610ML610UL610UL610UL610UL610UL610UL610ULG10UL610ULT

610UL.

Page 31: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 20 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

77 108 0.200.110.12

77 110 0.1577 112 0.1277 114 0.15

0.2377 116 0.2977 118 0.1477 138 0.2178 45 0.1578 71 0.22

0.240.20

78 73 0.250.22

78 75 0.170.170.15

78 77 0.150.170.250.18

78 79 0.1678 83 0.13

0.160.150.120.17

78 85 0.140.13

78 87 0.160.260.280.210.34

78 91 0.130.12

78 93 0.190:.15

78 95 0;.180.300.420.260.18

78 97 0.260.230.230.290.28

78 99 0.140.160.270.150.190.14

78 101 0.250.130.19

78 103 0.2378 105 0.40

0.340.250.41

DEG CHN

108 P2135 P2110 P292 P2124 P2118 P2112 P2103 P2103 P2107 P297 P2130 P2107 P2129 P2118 P2123 P2136 P2135 P2114 P2130 P2127 P2136 P2143 P2143 P2142 P2139 P2139 P2143 P2102 P2141 P290 P290 P2124 P2123 P2122 P2120 P2132 P298 P2136 P2138 P2132 P2138 P2130 P2143 P2148 P2158 P2154 P2156 P2143 P2154 P278 P293 P2122 P2101 P2103 P2143 P2129 P299 P2145 P2151 P2140 P2136 P2146 P2138 P2

IND %TW

TWD 8TWD 4TWD 5TWD 6TWD 5TWD 7TWD 9TWD 13TWD 6TWD 9TWD 6TWD 9TWD 9TWD 8TWD 10TWD 9TWD 7TWD 7TWD 7TWD 6TWD 7TWD 10TWD 8TWD 7TWD 5TWD 7TWD 6TWD 5TWD 7TWD 6TWD 5TWD 6TWD 9TWD 9TWD 7TWD 11TWD 5TWD 5TWD 7TWD 6TWD 7T iD 11TWD 14TWD 9TWD 7TWD 8TWD 7TWD 7TWD 8TWD 8TWD 5TWD 6TWD 10TWD 6TWD 7TWD 6TWD 9TWD 5TWD 7TWD 9TWD 13TWD 12TWD 9TWD 14

LOCATION EXT EXT

AVS +0.00 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAVS +0.00 TEH TECAV4 +0.22 TEH TECAV4 -0.04 TEH TECAVS -0.02 TEH TECAV5 -0.02 TEC TEHAV4 +0.15 TEC TEHAVS -0.20 TEC TEHAV4 +0.24 TEH TECAV2 +0.00 TEH TECAVS +0.09 TEH TECAVG +0.02 TEH TECAV3 +0.09 TEH TECAV7 +0.15 TEH TECAV3 +0.00 TEH TECAV7 +0.00 TEH TECAV8 +0.00 TEH TECAV2 +0.00 TEH TECAV4 +0.00 TEH TECAVS +0.00 TEH TECAVG +0.00 TEH TECAVG +0.00 TEH TECAV2 +0.02 TEH TECAV3 +0.00 TEH TECAVS +0.04 TEH TECAV4 +0.02 TEH TECAVG +0.04 TEH TECAV4 +0.04 TEH TECAVS +0.07 TEH TECAVG +0.00 TEH TECAVG +0.00 TEH TECAVS +0.11 TEH TECAV4 +0.02 TEH TECAV3 +0.00 TEH TECAVS -0.20 TEH TECAVG +0.09 TEH TECAVS +0.00 TEH TECAV4 +0.00 TEH TECAVS +0.00 TEH TECAV4 +0.00 TEH TECAV3 +0.00 TEH TECAV2 +0.00 TEH TECAVI +0.00 TEH TECAV2 -0.02 TEH TECAV3 -0.02 TEH TECAV4 +0.02 TEH TECAV5 -0.02 TEH TECAVG +0.02 TEH TECAV7 +0.20 TEH TECAVG +0.24 TEH TECAVS +0.07 TEH TECAV4 +0.20 TEH TECAV3 +0.02 TEH TECAV2 +0.00 TEH TECAVS -0.24 TEH TECAVG -0.22 TEH TECAV4 +0.00 TEH TECAV3 +0.00 TEH TECAV2 +0.00 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAVS +0.00 TEH TEC

UTIL 1 UTIL 2 CAL #

60606059624545403927363030302929272727272727272523232323232323474747474747474949494949494950505050505151515151515454545555555555

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDHOTHOTHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

61UL610UL61OUL610UL610UL61OUL610UL610UL6101UL610UL610UL610UL610UL6100UL610UL610UL61OUL610UL610UL61OUL610UL610UL610UL61OULG6OUL61001L610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL610T1L610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6101UL610UL610UL610UL610UL610UL

Page 32: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 21 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG

78 109 0.32 1200.18 100

78 1i1 0.16 900.15 92

78 117 0.25 10978 121 0.21 11878 137 0.16 10378 139 0.11 10878 143 0.15 11278 145 0.12 10579 68 0.17 14379 72 0.12 75

0.17 116

79 74 0.21 1150.24 1120.31 125

79 76 0.17 1280.26 1280.23 1140.23 1330.30 1330.16 95

79 78 0.21 13679 80 0.16 127

0.16 13279 82 0.15 14679 86 0.26 101

0.29 1220.19 107

79 90 0.22 1330.19 1280.13 1230.33 1160.20 1340.15 120

79 92 0.23 1410.18 1370.30 1410.37 1440.15 147

79 94 0.15 1500.22 1420.20 1350.20 1420.33 1370.32 1330.26 136

79 96 0.27 1390.31 128

79 98 0.30 1450.48 1340.50 1340.29 151

79 100' 0.37 1420.48 1250.37 145

79 102 0.28 1190.21 1300.26 1190.26 1040.16 109

CHN

P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2

IND %TW

TWO 12TWD 7TWD 6TWD 6TWD 12TWD 9TWD 7TWD 5TWO 7TWD 6TWD 7TWD 5TWD 7TWD 9TWD 9TWD 11TWD 7TWD 10TWD 9TWD 9TWD 12TWD 7TWD 9TWD 7TWD 7TWD 6TWD 10TWD 11TWD 8TWD 8TWD 7TWD 5TWD 11TWD 7TWD 5TWD 8TWD 7TWD 11TWD 12TWD 6TWD 6TWD 8TWD 7TWO 7TWD 11TWD 11TWD 9TWD 10TWD 11TWD 9TWD 13TWO 13TWD 9TWD 10TWD 13TWD 10TWD 10TWD 8TWD 9TWD 10TWD 6

LOCATION

AVS +0.00AV6 +0.04AV4 +0.11AVG +0.02AVS +0.24AVS -0.04AVS -0.22AVS -0.20AVS -0.26AV5 -0.13AV7 +0.07AV3 +0.31AVG +0.07AV4 +0.00AVS +0.00AVG +0.00AV3 +0.00AV4 +0.00AVS +0.00AVG +0.00AV7 +0.00AV8 +0.00AV7 +0.00AV3 +0.00AV5 +0.02AV7 +0.04AV7 +0.02AV3 -0.02AV4 +0.00AV2 +0.00AV3 +0.00AV4 +0.00AV5 +0.00AVG +0.00AV7 +0.09AVG +0.00AV5 +0.00AV4 +0.00AV3 +0.00AV2 +0.00AV8 +0.00AV7 +0.00AVG +0.00AV5 +0.00AV4 +0.00AV3 +0.00AV2 +0.00AVG +0.00AV2 +0.00AV3 +0.06AV4 +0,00AV5 +0.00AVG +0.09AV2 +0.00AV3 +0.00AV4 +0.00AVG +0.00AV4 +0.15AV3 +0.00AV5 +0.20AV7 -0.20

EXT EXT

TEN TECTEN TECTEN TECTEN TECTEC TERTEC TENTEC TENTEC TENTEC TENTEC TENTEN TEOTEE TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTER TECTEN TECTEN TECTEN TECTEN TECTER TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TEC

UTIL 1 UTIL 2 CAL #

595959594037272722222129292828282727272727272525252344444447474747474749494949494949494949494949495o5050505252525353535353

LEG

COLDCOLDCOLDCOLDHOTHOTHOTHOTHOTHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOILCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

61OUL610UL610UL61OUL610UL61OUL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610TL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6100L610UL610UL610UL610UL610UL610UL610UL610UL610UL6100.L61001L610UL61001.610UL610UL610UL610UL6100U161001.610UL

Page 33: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Rev. 0Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1 SG 2A, Page 22 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

79 106 0.26 112 P2 TWD 10 AV3 +0.00 TEH TEC 57 COLD 610ULL0.19 116 P2 TWD 8 AV4 +0.00 TEH TEC 57 COLD 610UL0.12 146 P2 TWD 5 AVG +0.17 TEH TEC 57 COLD 610UL0.10 121 P2 TWD 4 AV7 -0.19 TEH TEC 57 COLD 61001.

79 132 0.14 101 P2 TWD 7 AV2 -0.04 TEC TEH 30 HOT 610UL79 138 0.15 120 P2 TWD 8 AVS -0.22 TEC TEH 26 HOT 610UL80 67 0.15 128 P2 TWD 6 AVS -0.07 TEH TEC 22 COLD 610UL80 71 0.25 109 P2 TWD 10 AV4 -0.02 TEH TEC 29 COLD 61OUL

0.24 94 P2 TWD 9 AV5 +0.00 TEH TEC 29 COLD 610UL80 73 0.17 104 P2 TWD 7 AV5 +0.07 TEH TEC 30 COLD 610UL

0.13 127 P2 TWD 5 AV6 +0.00 TEH TEC 30 COLD 61OUL0.19 132 P2 TWD 8 AV7 +0.00 TEH TEC 30 COLD 610UL

80 75 0.22 117 P2 TWD 9 AV5 +0.00 TEH TEC 28 COLD 610UL0.22 113 P2 TWD 9 AV6 +0.00 TEH TEC 28 COLD 610UL0.23 124 P2 TWD 9 AV7 +0.00 TEH TEC 28 COLD 610UL

80 77 0.23 117 P2 TWD 9 AV3 +0.00 TEH TEC 28 COLD 610UL0.21 127 P2 TWD 8 AV4 +0.00 TEH TEC 28 COLD 610UL0.15 131 P2 TWD 6 AV5 +0.00 TEH TEC 28 COLD 610UL0.17 136 P2 TWD 7 AV6 +0.00 TEH TEC 28 COLD 610UL

80 83 0.17 120 P2 TWD 7 AV4 +0.00 TEH TEC 24 COLD 610UL0.27 120 P2 TWD 11 AV5 +0.00 TEH TEC 24 COLD 61OUL0.26 121 P2 TWO 10 AV7 +0.00 TEH TEC 24 COLD 610UL

80 85 0.14 116 P2 TWD 6 AV3 +0.00 TEH TEC 24 COLD 610UL0.20 103 P2 TWD 8 AV4 +0.00 TEH TEC 24 COLD 610UL0.19 132 P2 TWD 8 AV6 +0.00 TEH TEC 24 COLD 610UL

80 87 0.24 86 P2 TWD 6 AV2 +0.00 TEH TEC 45 COLD 610UL0.23 136 P2 TWD 10 AV3 +0.00 TEH TEC 45 COLD 61OUL0.27 120 P2 TWD 11 AV4 +0.00 TEH TEC 45 COLD 610UL0.18 117 P2 TWD 8 AV6 +0.00 TEH TEC 45 COLD 610UL0.18 121 P2 TWD 8 AV7 +0.00 TEH TEC 45 COLD 620UL

80 89 0.21 131 P2 TWO 7 AVG -0.02 TEH TEC 47 COLD 610UL0.26 121 P2 TWD 9 AV5 +0.00 TEH TEC 47 COLD 6100UL0.21 126 P2 TWD 7 AV4 +0.09 TEH TEC 47 COLD 610UL0.14 99 P2 TWD S AV3 -0.17 TEH TEC 47 COLD 6101UL

80 91 0.12 142 P2 TWO 5 AV5 -0.15 TEH TEC 47 COLD 6101UL0.19 122 P2 TWD 7 AVG +0.00 TEH TEC 47 COLD 610UL

80 93 0.34 124 P2 TWD 12 AV4 +0.00 TEH TEC 48 COLD 610UL0.30 135 P2 TWD 11 AV5 +0.00 TEH TEC 48 COLD 610UL0.13 141 P2 TWD 5 AVG +0.00 TEH TEC 48 COLD 610UL0.17 124 P2 TWD 6 AV7 +0.00 TEH TEC 48 COLD 610UL

80 95 0.25 125 P2 TWD 9 AV3 +0.00 TEH TEC 48 COLD 610UL0.27 123 P2 TWD 10 AV4 +0.00 TEH TEC 48 COLD 61OUL0.25 122 P2 TWD 9 AV5 +0.00 TEH TEC 48 COLD 61OUL

80 97 0.29 132 P2 TWD 10 AVG -0.15 TEH TEC 51 COLD 61001L0.27 126 P2 TWD 10 AV5 +0.00 TEH TEC 51 COLD 610UL0.23 129 P2 TWD 9 AV4 +0.00 TEH TEC 51 COLD 610UL0.18 113 P2 TWD 7 AV3 +0.00 TEH TEC 51 COLD 610UL0.15 121 P2 TWD 6 AV2 +0.00 TEN TEC 51 COLD 610UL

80 99 0.38 141 P2 TWD 11 AV4 +0.04 TEH TEC 50 COLD 610UL0.35 134 P2 TWD 10 AV5 +0.00 TEH TEC 50 COLD 610UL0.26 151 P2 TWD 8 AVG +0.00 TEH TEC 50 COLD 610UL

80 101 0.18 99 P2 TWD 7 AV7 +0.00 TEH TEC 53 COLD 610UL0.24 112 P2 TWO 9 AV5 -0.13 TEH TEC 53 COLD 6100UL0.21 125 P2 TWD 8 AV8 -0.02 TEH TEC 53 COLD 61001.

80 103 0.16 128 P2 TWD 6 AVG +0.00 TER TEC 56 COLD 61001.

0.15 76 P2 TWD 6 AV5 +0.00 TEH TEC 56 COLD 610UL0.21 87 P2 TWD 8 AV4 +0.00 TEH TEC 56 COLD 610UL0.46 110 P2 TWD 15 AV3 +0.00 TEH TEC 56 COLD 6101UL0.54 112 P2 TWD 17 AV2 +0.00 TEH TEC 56 COLD 610UL

80 105 0.21 127 P2 TWD 8 AV3 -0.04 TEH TEC 56 COLD 610UL0.33 106 P2 TWD 12 AV2 +0.00 TEH TEC 56 COLD 610UL

Page 34: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment I to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 23 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

80 109 0.390.310.200.34

80 111 0.2480 113 0.14

0.1680 117 0.16

0.1081 52 0.1381 62 0.1681 70 0.17

0.1681 76 0.20

0.340.300.16

81 78 0.2081 82 0.18

0.230.220.160.160.23

81 84 0.130.15

81 86 0.120.150.22

81 88 0.170.12

81 90 0.270.18

81 92 0.360.340.300.250.23

81 94 0.210.250.320.250.16

81 96 0.160.200.170.290.16

81 98 0.310.390.410.340.16

81 100 0.2281 102 0.42

0.3481 104 0.19

0.460.350.280.190.34

DEG CHN

111 P2131 P293 P2119 P2116 P2122 P2134 P2109 P287 P2100 P2117 P2135 P2127 P2134 P2109 P2109 P2108 P2121 P2139 P2131 P2129 P2132 P2124 P2137 P2127 P2119 P2137 P2137 P2133 P2119 P2125 P2122 P2108 P2127 P2137 P2117 P2121 P2135 P2116 P2133 P2125 P2131 P2144 P2139 P2130 P2119 P2132 P2134 P2123 P2126 P2121 P2120 P278 P2118 P2140 P2138 P2109 P2117 P2122 P299 P289 P2117 P2

IND %TW LOCATION EXT EXT UTIL I UTIL 2

TN]) 13 AV4 +0.00 TEN TECTWO 11 AV3 +0.00 TEN TECTWD 81 AV3 +0.00 TEN TECTWD 8 AV6 +0.00 TEH TEC

TWD 9 AV4 +0.00 TEN TECTWD 6 AV2 +0.02 TEN TECTWD 7 AV4 +0.20 TEN TECTWD 8 AV5 +0.20 TEN TECTW-D 5 AV5 -0.13 TEN TECTWD 5 AV4 +0.20 TEN TECTWD 6 AV3 +0.04 TEH TECTWD 7 AV6 +0.18 TEN TECTWD 7 AV7 +0.07 TEN TECTWD 8 AV3 -0.02 TEN TECTWD 12 AV4 +0.00 TEH TECTWD 11 AV5 +0.00 TEN TECTWD 7 AV7 +0.00 TEH TECTWD 8 AV4 +0.04 TEN TECTWD 8 AV2 +0.00 TEN TECTWD 9 AV3 +0.00 TEN TECTWD] 9 AV4 +0.00 TEH TECTWD 7 AV5 +0.00 TEN TECTWD 7 AV6 +0.00 TEN TECTWD 9 AV7 +0.00 TEN TECTWD 6 AV5 +0.02 TEN TECTWD 7 AV6 +0.00 TEN TECTWD 6 AV3 +0.00 TEN TECTWD 6 AV5 +0.00 TEH TECTWD 9 AV7 +0.00 TEN TECTWD 6 AV6 +0.04 TEN TECTWD 5 AV5 +0.00 TEN TECTWD 9 AV3 +0.00 TEH TECTWD 7 AV5 +0.00 TEN TECTWD 12 AV2 +0.00 TEN TECTN] 12 AV3 +0.00 TEN TECTWD 11 AV4 +0.00 TEN TECTWD 9 AV5 +0.00 TEH TECTWD 8 AV6 +0.00 TEN TECTWD 8 AV2 +0.00 TEN TECTWD 9 AV3 +0.00 TEN TECTWD 11 AV4 +0.00 TEN TECT•N] 9 AVE +0.00 TEN TECTWD 6 AV6 +0.00 TEN TECTWD 6 AV2 +0.00 TEN TECTWD 7 AV4 +0.00 TEN TECTWD 7 AV5 +0.00 TEN TECTWD 10 AV6 +0.00 TEN TECTWD 6 AV7 +0.00 TEN TECTWD 11 AV6 +0.15 TEN TECTWD 13 AV5 +0.00 TEN TECTWD 14 AV4 +0.00 TEN TECTWD 12 AV3 +0.00 TEN TECTWD 6 AV2 +0.00 TEN TECTWD 8 AV2 +0.00 TEH TECTWD 13 AV4 +0.00 TEH TECTWD 11 AV6 +0.00 TEN TECTWD 8 AV7 +0.00 TEN TECTWD 15 AVE +0.00 TEN TECTWD 12 AVE +0.00 TEN TECTWD 10 AV4 +0.15 TEN TECTWD 8 AV3 +0.17 TEN TECTWD 12 AV2 +0.00 TEN TEC

CAL #

6060606060454512123318323228282828262424242424242424454545474747474848484848484848484848484848485151515151535454565656565656

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

61OUL610UL610UL61OUL610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL61001610UL61OUL610UL610UL6100161OUL61001.610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6101UL610UL610UL61001.6101UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

Page 35: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 24 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

81 106 0.310.36

0.160.18

81 112 0.150.14

81 114 0.1282 45 0.1482 55 0.1582 71 0.51

0.1682 73 0.30

0.2482 75 0.33

0.360.160.16

82 77 0.200.250.250.26

82 79 0.300.23

82 81 0.170.18

82 83 0.200.180.150.25

82 85 0.130.300.270.22

82 87 0.1882 89 0.13

0.210.30

82 91 0.310.200.220.19

82 93 0.260.230.230.17

82 95 0.230.230.170.130.280.20

82 97 0.440.27

82 99 0.140.220.230.170.10

82 101 0.260.120.19

DEG CHN

127 P2123 P2126 P2129 P2115 P299 P2127 P2138 P2118 P2128 P285 P2110 P2104 P2130 P2131 P2129 P2133 P2125 P2134 P2122 P2118 P2135 P2134 P2137 P2126 P2137 P2136 P2141 P2136 P2122 P2129 P2118 P2118 P2112 P2122 P2126 P2127 P2134 P2128 P2126 P2115 P2132 P2147 P2142 P2146 P2138 P2134 P2137 P2157 P2132 P2140 P2147 P2155 P292 P2123 P299 P2115 P290 P2126 P2118 P2144 P2

IND %TW

TWD 11TWO 13TWO 6TWO 7TWD 6TWO 6TWDO5TWO 6TWD 6TWO 17TWO 7TWO 11TWD 9TWD 13TWO 13TWO 7TWO 7TWO 8TWO 10TWD 10TWD 10TWO 12TWO 9

TWO 7TWO 8TWO 8TWO 7

TWO 6TWO 10TWO 6TWO 11TWO 10TWO 9TWD 7TWDO5

TWO 7TWO 10TWO 10TWO 7TWO 8TWO 7TWO 10TWO 9TWO 9TWO 7TWO 8TWO 8TWO 7TWDO5TWO 10TWO 7TWO 12TWO 8TWDO5TWO 8TWO 9TWO 7TWO 4

TWO 9TWO 5TWO 7

LOCATION

AV2 +0.04AV3 +0.02AV4 +0.02AVG +0.02AVG +0.20AV2 -0.22AV5 -0.26AV4 +0.20AV4 -0.15AV2 +0.07AV4 -0.15AVG +0.00AV7 +0.00AV2 +0.00AV3 +0.00AV5 +0.00AVG +0.00AV3 +0.00AVG +0.00AV7 +0.00AV8 +0.00AV3 +0.00AV4 +0.00AV3 +0.02AV7 +0.04AV4 +0.00AV5 +0.02AVG +0.02AV7 +0.02AV4 -0.20AV5 +0.00AVG +0.04AV7 -0.04AV4 +0.02AV5 +0.04AV4 +0.00AV3 -0.04AV4 +0.00AVS -0.20AVG +0.00AV7 +0.04AV7 +0.00AVG +0.00AV4 +0.00AV2 +0.00AV7 +0.00AVS +0.00AV4 +0.00AV3 +0.00AV2 +0.00AVI +0.00AV2 -0.02AVG +0.00AV7 +0.20AVG +0.20AV5 +0.26AV4 +0.20AV3 +0.20AV5 -0.19AVE -0.26AV7 +0.00

EXT EXT

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEN TECTEH TECTEH TECTEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTER TEC

UTIL 1 UTIL 2 CAL #

5858585862624536313030292927272727272727272525252523232323232323234447474747474747494949494949494949495050

5151515151545454

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL610UJL61OUL

610UL610UL61001L610UL610UL610UL610UL610UL610UL61OUL61001461OUL610UL610UL610UL610UL610UL610014610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6100L610UL610UL610014

610UL610UL610UL610UL610UL610UL610UL610014610UL

Page 36: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 25 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

82 103 0.510.320.300.240.220.20

82 105 0.150.190.410.230.18

82 115 0.1582 127 0.1582 133 0.1583 36 0.1483 50 0.1583 70 0.24

0.150.18

83 72 0.1683 76 0.25

0.400.290.440.31

83 78 0.170.310.200.15

83 80 0.250.19

83 82 0.150.16

B3 84 0.270.190.200.150.23

83 86 0.210.270.220.150.15

83 88 0.160.220.15

83 90 0.150.240.560.130.210.340.230.21

83 92 0.260.320.270.260.650.220.18

DEG CHN

139 P2138 P2142 P2134 P2151 P2145 P2150 P2151 P2141 P2152 P2138 P286 P2144 P297 P2101 P2100 P2119 P2124 P2121 P2105 P2130 P2126 P2120 P2133 P2117 P2136 P2139 P2130 P2144 P2140 P2132 P2138 P2126 P2130 P2137 P2114 P2118 P211 P2123 P2119 P2105 P2128 P2119 P2137 P2136 P2143 P2125 P2123 P2120 P2137 P2119 P2118 P2136 P2141 P2146 P2132 P2143 P2119 P2129 P2144 P2162 P2

IND %TW LOCATION

TWD 16 AV2 +0.00TWD 11 AV3 +0.00TWD 11 AV5 +0.00TWD 9 AV6 +0.06TWD 8 AV7 +0.00TWD 8 AV8 +0.00TWD 6 AVI +0.00TWD 7 AV2 +0.00TWD 13 AV3 +0.00TWD 8 AV4 +0.00TWD 7 AV5 +0.00TWD 8 AVS -0.33TWD 6 AV3 -0.02TWD 6 AV5 -0.09TWD 6 AV4 +0.20TWD 7 AV4 +0.24T iD 10 AVI +0.07TWD 7 AV3 +0.00TWD 8 AV5 +0.04TWD 7 AV5 +0.02TWD 10 AV2 +0.00TWD 15 AV3 +0.00TED 11 AV5 +0.00TWD 16 AV6 +0.00TWD 12 AV7 +0.00TWD 7 AV3 +0.00TWD 12 AV4 +0.00TWD 8 AV5 +0.00TWD 7 AV6 +0.00TWD 10 AV4 +0.00TWD 8 AV6 +0,02TWD 6 AV3 -0.02TWD 7 AV7 +0.07TWD 10 AV3 +0.02TWD 8 AV4 +0.07TWD 8 AV5 +0.11TWD 6 AV6 -0.02TWD 9 AV7 +0.02TWD 8 AV7 +0.00TWD 10 AV6 +0.00TWD 8 AV5 +0.15TWD 6 AV3 +0.00TWD 6 AV4 +0.00TWD 6 AV6 +0.00TWD 8 AVS +0.00TWD 6 AV4 +0.00TWD 6 AVi +0.00TWD 8 AV2 +0.00TWD 16 AV3 +0.00TWD 5 AV4 +0.00TWD 7 AV5 +0.00TWD 11 AV6 +0.00TWD 8 AV7 +0.00TWD 7 AV8 +0.00TWD 9 AV7 +0.00TWD 11 AV6 +0.00TWD 10 AV5 +0.00TWD 10 AV4 +0.15TWD 19 AV3 +0.00TWD 8 AV2 +0.00TWD 7 AV8 +0.00

EXT EXT UTIL 1 UTIL 2

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEC TEHTEC TEHTEC TEHTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

CAL #

55555555555555555555554133291134313131292727272727252525252525232323232323234444444444464646474747474747474749494949494949

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDHOTHOTHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

61OUL610UL610UL61OUL61 OUL61OUL61011610UL610UL610UL61OUL610UL610UL610UL610UL610UL610UL610UL61OUL610UL6101,UL610UL61OUL610UL610UL61OUL61OUL610UL61OUL61OUL610UL6101,610UL610UL

10OUL610UL61011610UL610UL610UL610UL61OUL610UL61OUL610UL61011610UL610UL61OUL610UL610UL610UL61011UL610UL610UL610UL61OUL610UL610UL610UL61OUL

Page 37: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 26 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

83 94 0.220.270.320.340.270.290.29

83 96 0.210.220.140.290.580.19

83 98 0,380.690.440.350.29

83 100 0.290.330.38

83 102 0.290.410.310.28

83 104 0.270.290.290.35

83 106 0.1583 108 0.15

0.2583 112 0.1283 116 0.2183 150 0.1384 63 0.3284 71 0.16

0.2884 75 0.3484 77 0.31

0.180.340.340.20

84 79 0.180.26

84 81 0.3384 83 0.1584 85 0.31

0.150.170.220.19

84 87 0.360.360.200.26

84 89 0.290.310.410.26

84 91 0.180.230.26

DEG CHN

144 P2138 P2132 P2139 P2127 P2139 P2131 P2137 P2137 P2152 P2122 P2125 P2137 P2154 P2130 P2145 P2148 P2152 P2149 P2139 P2137 P2116 P2108 P2120 P2102 P2148 P2148 P2145 P2139 P2108 P280 P2118 P2119 P296 P2120 P2117 P285 P2112 P2123 P2114 P2128 P2121 P2115 P2132 P2129 P2118 P2122 P2135 P2116 P2126 P2140 P2115 P2117 P2122 P2121 P2140 P2128 P2120 P2125 P2126 P2132 P2128 P2133 P2126 P2

IND %TW

TWD 8TWD 10TWO 11TWO 12TWD 10TWD 10TWD 10TWD 8TWD 8TWD 5TWD 10TWO 17TWD 7TWD 11TWD 17TWO 12TWD 10TWD 8TWD 8TWD 9TWO 11TWD 10TWD 13TWD 11TWD 10TWD 10

TWD 10TWD 10TWD 12TWD 6TWD 6TWD 10TWD 5TWD 10TWD 7TWD 12TWD 7TWD 10TWD 12TWD 11TWO 7TWD 12TWD 12TWD 8TWD 7TWD 10TWD 12TWD 7TWD 12TWD 7TWD 7TWD 9TWO 8TWO 13TWD 14TWD 9TWO 11TWD 10TWD 10TWD 13TWD 9TWD 6TWD 8TWD 9

LOCATION EXT EXT

AV8 +0.00 TEH TECAV7 +0.00 TEH TECAV6 +0.00 TEH TECAVE +0.00 TEH TECAV4 +0.00 TEH TECAV3 +0.00 TEW TECAV2 +0.00 TEH TECAV7 +0.00 TEH TECAV6 +0.00 TEH TECAVE +0.00 TEH TECAV4 +0.00 TEH TECAV3 +0.00 TEH TECAV2 +0.00 TEH TECAV2 +0.00 TEH TECAV3 +0.00 TEH TECAV4 +0.04 TEH TECAV5 +0.02 TEH TECAV6 +0.02 TEH TECAV2 +0.00 TEH TECAV4 +0.02 TEH TECAVG +0.06 TEH TECAVG +0.02 TEH TECAV4 +0.00 TEH TECAV3 +0.00 TEH TECAV5 +0.15 TEH TECAV2 +0.00 TEH TECAV5 +0.00 TEH TECAVG +0.00 TEH TECAV4 +0.00 TEH TECAV6 +0.26 TER TECAVE +0.26 TEH TECAVG +0.02 TEH TECAVG +0.17 TEH TECAV2 -0.07 TEC TEHAVI -0.20 TEC TEHAV2 -0.02 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAV3 +0.00 TEH TECAV3 +0.00 TEH TECAV5 +0.00 TEH TECAVG +0.00 TEH TECAV7 +0.00 TEH TECAV8 +0.00 TEH TECAV5 +0.00 TEH TECAVG +0.02 TEH TECAVE +0.07 TEH TECAV2 +0.02 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAV5 +0.00 TEH TECAVG +0.00 TEH TECAV7 +0.00 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAVE +0.00 TEH TECAVG +0.00 TEH TECAVE +0.00 TEH TECAV4 -0.02 TEH TECAV3 -0.02 TEH TECAVG +0.00 TEH TECAVG +0.00 TEH TECAVE -0.13 TEH TECAV4 +0.00 TEH TEC

UTIL I UTIL 2 CAL # LEG

49 COLD49 COLD49 COLD49 COLD49 COLD49 COLD49 COLD49 COLD49 COLD49 COLD49 COLD49 COLD49 COLD50 COLD50 COLD50 COLD50 COLD50 COLD52 COLD52 COLD52 COLD53 COLD53 COLD53 COLD53 COLD55 COLD55 COLD55 COLD55 COLD57 COLD59 COLD59 COLD61 COLD40 HOT20 HOT20 COLD29 COLD29 COLD28 COLD28 COLD28 COLD28 COLD28 COLD28 COLD26 COLD26 COLD26 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD45 COLD45 COLD45 COLD45 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD

PROBE

610UL6101L610UL610UL610UL610TUL610UL610UL61OULGO1UL6101LL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001L610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

Page 38: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment I to Enclosure I

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 27 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN

84 93 0.150.270.190.370.280.450.420.32

84 95 0.150.570.280.39

84 97 0.160.140.310.230.170.28

84 99 0.270.530.220.440.340.450.33

84 101 0.190.170.19

84 103 0.170.380.28

84 105 0.200.290.180.17

84 107 0.260.190.150.380.23

84 109 0.160.290.240.250.300.27

84 113 0.130.14

84 115 0.210.16

84 117 0.280.270.310.30

84 125 0.1885 36 0.1085 68 0.2585 70 0.1785 72 0.16

0.340.290.22

85 74 0.32

121 P2135 P2121 P2125 P2135 P2125 P2132 P2138 P2134 P2118 P2125 P2122 P2104 P2144 P2121 P2122 P298 P2I11 P2158 P2144 P2156 P2135 P2115 P2134 P2151 P283 P288 P2122 P2129 P2106 P2121 P298 P299 P2114 P2123 P2112 P2114 P2124 P2114 P2139 P2129 P2129 P2126 P2117 P2117 P2104 P2133 P2120 P296 P295 P2103 P2119 P2109 P2120 P2147 P297 P2130 P2125 P2134 P2122 P2123 P2134 P2107 P2

IND %TW

TWD 6TWD 10TWD 7

TWD 13TWD 10TWD 15TWD 14TWD 11TWD 6T•D 17

TWD 10TWD 13TWD 6TWD 5TWD 11TWD 9TWD 6TWD 10TWD 8TWD 14TWD 7TWD 12TWD 10TWD 12TWD 9TWD 7TWD 6TWD 7

TWD 7TWD 13TWD 10TWD 8T iD 11TWD 7TWD 7TWD 10TWD 8TWD 6TWD 13TWD 9TWD 6TWD 11

TWD 9TWD 9TWD 11TWD 10TWD 6TWD 6TWD 10TWD 8TWD 13TED 12TWD 13TWO 13TWD 8TWD 5TWD 10TWD 7TWD 7TWD 12TWD 11TWD 9TED 12

LOCATION

AVI +0.07AV2 +0.00AV3 +0.00AV4 +0.00AVS +0.00AV6 +0.00AV7 +0.00AV8 +0.00AVl +0.00AV2 +0.00AV3 +0.00AV4 +0.00AV7 +0.00AV6 +0.00AV5 +0.00AV4 +0.00AV3 +0.00AV2 +0.00AVI +0.00AV2 +0.00AV3 +0.00AV4 +0.00AV5 +0.00AV6 +0.00AV7 +0.00AV4 +0.00AV7 +0.07AVS +0.00AV7 +0.00AV3 +0.00AVI +0.00AV6 +0.09AV3 +0.00AV2 +0.00AVI +0.00AV3 +0.00AV4 +0.07AVS +0.00AV6 +0.07AV7 +0.04AV4 +0.00AV2 +0.00AVI +0.00AV5 +0.00AV3 +0.00AV2 +0.00AV2 +0.29AVS +0.09AVS +0.18AV4 +0.07AVS +0.24AV4 +0.04AV3 +0.00AV2 +0.00AV2 -0.11AV4 +0.22AV7 +0.09AV3 +0.02AV2 +0.00AV3 +0.00AV4 +0.00AV5 +0.00AV8 +0.17

EXT EXT

TEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTER TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTER TECTEN TECTEN TECTEN TECTEN TECTEN TECTEE TECTEN TECTEN TECTEN TECTEN TECTEE TECTEN TECTEN TECTEN TECTEN TECTEN TECTEE TECTEN TECTEN TECTEN TECTER TECTER TECTEE TECTEN TECTEN TECTEN TECTEN TECTEE TECTEN TECTEN TECTEN TECTEC TEETEC TERTEC TENTEC TENTEC TENTEC TEETEC TENTEN TECTEN TECTEH TECTEN TECTEN TECTEN TECTEN TECTEN TEC

UTIL 1 UTIL 2 CAL # LEG

48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD51 COLD51 COLD51 COLD51 COLD51 COLD51 COLD50 COLD50 COLD50 COLD50 COLDso COLD50 COLDso COLD53 COLD53 COLD53 COLD56 COLD56 COLD56 COLD56 COLD56 COLD56 COLD56 COLD58 COLD58 COLD58 COLD58 COLD58 COLD60 COLD60 COLD60 COLD60 COLD60 COLD60 COLD45 COLD45 COLD41 HOT41 HOT40 HOT40 HOT40 HOT40 HOT35 HOT12 COLD22 COLD32 COLD30 COLD30 COLD30 COLD30 COLD29 COLD

PROBE

610UL610UL610UL610UL610UL6101L361OUL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61OUL61OUL610UL610UL610UL610UL1610UL61OUL610UL61OUL610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL61OUL610UL610UL61OUL610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL61OUT-610UL610UL610UL,610UL61OUT,

Page 39: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 28 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

85 76 0.230.220.500.27

85 78 0.1785 80 0.21

0.1685 82 0.22

0.170.180.31

85 84 0.210.250.180.410.310.27

85 86 0.200.130.280.39

85 88 0.120.250.220.16

85 90 0.2S0.140.13

85 92 0.130.370.380.300.300.12

85 94 0.130.190.350.320.150.18

85 96 0.210.340.16

85 98 0.180.250.400.36

85 100 0.220.340.180.230.20

85 102 0.3185 104 0.21

0.340.350.310.360.16

85 106 0.220.20

85 110 0.3085 112 0.23

DEG CHN

120 P2115 P2122 P2125 P2130 P2101 P2131 P2115 P2113 P2127 P2122 P2126 P2133 P2133 P2127 P2129 P2110 P2120 P2121 P2130 P2123 P2140 P2120 P2124 P267 P2123 P2119 P2105 P2146 P2132 P2123 P2127 P2133 P2145 P2113 P2131 P2134 P2133 P2130 P2143 P2126 P2129 P2131 P298 P2115 P2115 P2130 P2110 P2118 P272 P2116 P2121 P2128 P293 P2116 P2110 P2119 P2117 P2106 P2126 P2III P2123 P2128 P2

IND %TW LOCATION

TWD 9 AV3 +0.00TWD 9 AVS +0.00TWD 16 AV6 +0.00TWD 10 AV7 +0.00TWD 7 AV7 +0.04TWD 8 AVG +0.07TWD 6 AV7 +0.04TWD 9 AV3 +0.00TWD 7 AV5 +0.00TWD 8 AVG +0,00TWD 12 AV7 +0.00TWD 9 AV2 +0,00TWD 10 AV3 +0.00TWD 8 AV4 +0.00TWD 15 AVS +0.00TWD 12 AV6 +0.00TWD 11 AV7 +0.00TWD 8 AV3 +0.00TWD 6 AVS +0.00TWD 11 AVG +0.00TWD 14 AV7 +0.00TWD 4 AV6 +0.00TWD 9 AVS -0.02TWD 8 AV4 +0.02TWD 6 AV2 +0.09TWD 9 AV2 +0.00TWD 5 AV3 +0.00TWD 5 AV5 +0.00TWD 5 AV2 +0.00TWD 13 AV3 +0.00TWD 13 AV4 +0.00TWD 11 AV5 +0.00TWD 11 AV7 +0.00TWD 5 AV6 +0.00TWD 5 AVI +0.00TWD 7 AV3 +0.00TWD 12 AV4 +0.00TWD 11 AV5 +0.00TWD 6 AV7 +0.00TWD 7 AV8 +0.00TWD 8 AV5 +0.00TWD 12 AV6 +0.00TWD 6 AV7 +0.00TWD 7 AV6 +0.00TWD 9 AV5 +0.00TWD 13 AV4 +0.00TWD 12 AV3 +0.00TWD 8 AV2 +0.00TWD 12 AV3 +0.00TWD 7 AV4 +0.00TWD 8 AV5 +0.00TWD 7 AV7 +0.00TWD 11 AV5 +0.24TWD 8 AV7 +0.00TWD 12 AV6 +0.00TWD 12 AV5 +0.00TWD 11 AV4 +0.00TWD 13 AV2 -0.02TWD 6 AV1 +0.00TWD 9 AV3 -0.04TWD 8 AV7 +0.15TWD 11 AV5 +0.09TWD 9 AV2 +0.00

EXT EXT

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

UTIL I UTIL 2 CAL #

282828282626262424242424242424242445454545474747474747474848484848484848484848484848485151515153535353535456565656565658585962

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL

610UL610UL61UOL610ULL610ULT610UL610UL610UL610UL610UL610UL610UL610UL

610UL610ULG10UL6 1OUL610UL610UL61001.61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6101UL610UL610UL6O1UL610UL610UL610UL61001.

61001.610UL610UL610UL610UL

61001.

61UOL610UL61001.61OUL61OUL61001L610UL610UL61001.610UL61001.

61 OUL

Page 40: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Rev. 0Steam Generator Tube Inspection Report

Attachment I to Enclosure 1 SG 2A, Page 29 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

85 114 0.22 133 P2 TWD 9 AV3 -0.02 TEH TEC 45 COLD 610UL0.13 136 P2 TWD 6 AV6 +0.04 TER TEC 45 COLD 61OUL

86 63 0.15 136 P2 TWD 6 AVI +0.00 TEH TEC 19 COLD 610UL86 71 0.26 132 P2 TWD 10 AV4 -0.04 TEH TEC 30 COLD 610UL

0.24 127 P2 TWD 9 AVS +0.00 TER TEC 30 COLD 610UL0.17 147 P2 TWD 7 AV6 +0.13 TER TEC 30 COLD 610UL0.15 144 P2 TWD 6 AV7 +0.02 TEE TEC 30 COLD 61OUL

86 73 0.40 112 P2 TWD 14 AV6 +0.00 TEE TEC 29 COLD 61OUL0.20 96 P2 TWD 8 AV7 +0.00 TEE TEC 29 COLD 610UL

86 75 0.50 125 P2 TWD 17 AV2 +0.00 TEE TEC 27 COLD 610UL86 77 0.34 132 P2 TWD 13 AV7 +0.00 TER TEC 27 COLD 610UL

0.26 120 P2 TWD 10 AV6 +0.00 TEH TEC 27 COLD 610UL0.16 137 P2 TWD 7 AV3 -0.04 TER TEC 27 COLD 610UL0.16 132 P2 TWD 7 AV4 +0.02 TEE TEC 27 COLD 610UL0.16 116 P2 TWD 7 AV5 +0.00 TEH TEC 27 COLD 610UL

86 79 0.28 123 P2 TWD 11 AV3 +0.00 TEH TEC 25 COLD 610UL86 81 0.35 135 P2 TWD 13 AVS +0.02 TEH TEC 25 COLD 610UL

0.20 134 P2 TWD 8 AV6 +0.00 TER TEC 25 COLD 610UL86 83 0.12 148 P2 TWD 5 AV3 +0.00 TER TEC 23 COLD 610UL

0.23 130 P2 TWD 9 AV4 +0.11 TER TEC 23 COLD 610UL0.15 120 P2 TWD 6 AV6 +0.00 TER TEC 23 COLD 610UL

86 85 0.14 99 P2 TWD 6 AV3 +0.07 TER TEC 23 COLD 61OUL0.26 125 P2 TWD 10 AV4 -0.02 TER TEC 23 COLD 61OUL0.25 134 P2 TWD 10 AV5 +0.00 TER TEC 23 COLD 610UL0.28 117 P2 TWD 11 AV6 +0.09 TEE TEC 23 COLD 610UL0.16 113 P2 TWD 7 AV7 +0.07 TEE TEC 23 COLD 610UL

86 87 0.18 108 P2 TWD 7 AV5 +0.00 TEE TEC 44 COLD 61OUL0.27 101 P2 TWD 10 AV4 +0.00 TEE TEC 44 COLD 610UL0.26 120 P2 TWD 10 AV3 +0.00 TER TEC 44 COLD 610UL

86 89 0.19 125 P2 TWD 7 AV5 +0.00 TEE TEC 47 COLD 610UL0.27 124 P2 TWD 9 AV4 +0.00 TEE TEC 47 COLD 610UL0.24 124 P2 TWD 8 AV3 -0.02 TEE TEC 47 COLD 610UL0.31 122 P2 TWD 10 AV2 +0.00 TEE TEC 47 COLD 610UL0.22 134 P2 TWD 8 AV6 +0.00 TEE TEC 47 COLD 610UL

86 91 0.31 131 P2 TWD 10 AV6 +0.02 TEH TEC 47 COLD 610UL0.21 132 P2 TWD 7 AV5 +0.00 TEE TEC 47 COLD 610UL0.34 115 P2 TWD 11 AV4 -0.04 TEE TEC 47 COLD 610UL

86 93 0.35 138 P2 TWD 12 AV6 +0.00 TEE TEC 49 COLD 610UL0.25 134 P2 TWD 9 AVS +0.00 TEH TEC 49 COLD 61OUL0.25 137 P2 TWD 9 AV4 +0.00 TEE TEC 49 COLD 610UL0.24 140 P2 TED 9 AV3 +0.00 TER TEC 49 COLD 61001.0.27 136 P2 TWO 10 AV2 +0.00 TEE TEC 49 COLD 61OUL

86 95 0.31 138 P2 TWD 11 AV5 +0.00 TEE TEC 49 COLD 610UL0.46 131 P2 TWO 15 AV4 +0.00 TEE TEC 49 COLD 610UL0.12 151 P2 TWD 5 AV3 +0.00 TEH TEC 49 COLD 610UL0.34 137 P2 TWD 12 AV2 +0.00 TEE TEC 49 COLD 610UL0.18 150 P2 TWD 7 AVI +0.00 TEE TEC 49 COLD 610UL

86 97 0.24 152 P2 TWD 7 AV2 +0.04 TEE TEC 50 COLD 610UL86 99 0.14 77 P2 TWD 6 AV7 +0.20 TEE TEC 51 COLD 610UL

0.16 98 P2 TWD 6 AV6 +0.22 TEE TEC 51 COLD 610UL0.20 101 P2 TWD 7 AV3 +0.07 TEE TEC 51 COLD 610UL0.11 88 P2 TWD 5 AV2 +0.20 TEE TEC 51 COLD 610UL

86 103 0.50 134 P2 TWD 16 AV2 +0.00 TEE TEC 55 COLD 610UL86 105 0.21 137 P2 TWD 8 AV3 +0.00 TEE TEC 55 COLD 610UL

0.20 151 P2 TWD 7 AV7 +0.00 TER TEC 55 COLD 610UL86 109 0.16 125 P2 TWD 7 AV3 +0.00 TER TEC 59 COLD 6O1UL86 125 0.16 109 P2 TWD 8 AV2 -0.02 TEC TEE 34 HOT 610UL87 74 0.20 122 P2 TWD 8 AVS +0.04 TEE TEC 30 COLD 610UL87 76 0.15 137 P2 TWD 6 AV2 +0.00 TEE TEC 27 COLD 610UL

0.18 122 P2 TWD 8 AV7 +0.00 TEE TEC 27 COLD 610UL87 80 0.24 139 P2 TWD 10 AV4 +0.00 TEE TEC 25 COLD 610UL

0.18 126 P2 TWD 8 AV6 +0.00 TEE TEC 25 COLD 610UL0.16 137 P2 TWD 7 AV7 +0.00 TEE TEC 25 COLD 610UL

Page 41: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 30 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

87 82 0.360.160.190.220.33

87 84 0.120.160.260.200.24

87 86 0.220.220.53

87 88 0.260.240.15

87 90 0.140.340.170.270.260.200.16

87 92 0.250.390.190.210.470.38

87 94 0.310.320.270.310.240.260.16

87 96 0.610.260.150.160.180.38

87 98 0.550.430.230.460.370.33

87 100 0.300.36

87 102 0.150.270.470.39

87 204 0.370.190.330.530.320.23

87 106 0.1887 108 0.21

0.30

DEG CHN

132 P2136 P2126 P2133 P2125 P2101 P2138 P2118 P2134 P2117 P2113 P2128 P2130 P2138 P2143 P2120 P2120 P2117 P2135 P2115 P2111 P2114 P2137 P2139 P2135 P2143 P2125 P2141 P2132 P2140 P2136 P2141 P2134 P2139 P2133 P2143 P2120 P2127 P2129 P2149 P2142 P2121 P2132 P2141 P2153 P2139 P2146 P2105 P2134 P2137 P2104 P2100 P2110 P2126 P2137 P2148 P2141 P2137 P2144 P2145 P2136 P2143 P2121 P2

IND %TW

rWo 13

TWD 7TWD 8TWD 9TWD 12TWD 5TWD 7TWD 10TWD 8TWD 9TWD 8TWD 9TWD 17TWD 9TWD 9TWD 6TWD 5TWD 11TWD 6TWD 9TWD 9TWD 7TWD 6TWD 9TWD 13TWD 7TWD 8TWD 15TWD 13TWD 11TWO 11

TWD 10TWD 11TWD 9TWD 9TWD 6TWD 18TWD 10TWD 6TWD 6TWD 7TWD 13TWD 14TWD 12TWD 7TWD 13TWD 11TWD 9TWD 9TWD 10TWD 6TWD 10TWD 15TWD 13TWD 12TWD 7TWD 11TWD 16TWO 11TWD 8TWD 7TWD 8TWD 11

LOCATION

AV3 +0.04AV4 +0.04AVS +0.04AV6 +0.09AV7 +0.04AV2 +0.02AV4 +0.04AVS +0.07AV6 +0.07AV7 +0.00AVG +0.00AV5 +0.00AV3 +0.00AVS +0.00AV4 +0.00AV2 +0.00AV2 +0.20AV3 +0.00AV4 +0.00AVS +0.00AV6 +0.09AV7 +0.00AV8 +0.00AV7 +0.00AV7 +0.00AVS +0.00AV4 +0.17AV3 +0.00AV2 +0.00AV7 +0.00AVG +0.00AV5 +0.00AV4 +0.00AV2 +0.00AVI +0.00AV3 +0.00AV3 +0.00AV2 +0.00AVi +0.00AVG +0.00AV5 +0.00AV4 +0.00AV6 +0.00AV7 +0.02AV2 +0.00AV3 +0.04AV4 +0.00AVS +0.00AV4 +0.00AV3 -0.02AVG +0.00AV5 +0.24AV4 +0.00AV3 +0.00AVG +0.00AV7 +0.00AV2 +0.00AV3 +0.00AV4 +0.00AV5 +0.00AV2 +0.00AV3 +0.06AV4 +0.11

EXT EXT

TEN TOOTEH TECTEH TECTEH TECTEH TECTEH TWCTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TOCTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

UTIL 1 UTIL 2 CAL #

23232323232323232323444444464646474747474747474949494949494949494949494949494949494950505o5o5050525253535353555555555555575959

LEG

COLDCOLDcola)COLD

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD)COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL610UL610UL610UL610UL610UL61001.610UL610UL610UL610UL610ULT6101UL610UL610UL6101.UL610UL061OUL6103L610UL610UL610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001L610UL610UL61001.610UL61011610UL6100L.6100LL610UL610UL610UL610UL610UL61001.610UL610UL6100UL610UL6101L61001L61OUL

Page 42: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 31 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

87 110 0.1387 112 0.2087 114 0.21

0.2087 116 0.15

0.1788 63 0.1788 65 0.1588 69 0.1288 71 0.19

0.2188 73 0.27

0.480.23

88 75 0.170.190.17

88 77 0.170.210.160.15

88 81 0.210.260.300.210.350.22

88 87 0.130.280.160.330.260.16

88 89 0.2388 91 0.12

0.270.190.350.33

88 93 0.310.220.13

88 95 0.210.460.390.24

88 97 0.120.14

88 99 0.230.43

88 101 0.200.300.20

88 103 0.230.280.190.36

88 105 0.200.15

88 107 0.2088 109 0.1988 113 0.21

DEG CHN

129 P2149 P2113 P2106 P270 P288 P297 P2135 P2122 P2109 P291 P2117 P2121 P2137 P2118 P2119 P2144 P2114 P2137 P2126 P2131 P2123 P2128 P2125 P2122 P2125 P2121 P2105 P2120 P2113 P2127 P2I11 P2119 P2123 P2108 P2123 P2126 P2122 P2119 P2128 P2122 P2140 P2131 P2123 P2123 P2120 P2118 P2130 P2157 P2138 P299 P2122 P2102 P2110 P2109 P2110 P2124 P2114 P276 P2119 P2120 P2116 P2

IND %TW

TWE 5TWD 8TWH 8TWH 8TWH 7TWH 9TWH 7TWH 6

TWH 5TWD 8TWH 8THD 10THE 16TWH 9TWH 7

TWH 8TWH 7TWD 7TWE 8TWH 7

TWH 6TWH 9TH 10THE 11TWH 8THE 13'TWD 9TWH 6THE 11TWH 7THE 13THE 11

TWE 7TWH 8TWH S

TWH 9TWH 7

THE 11THE 11THE 11TWH 8

TWH 5TWH 8THE 15THE 13TwH 9TWE 5TWH 5TWH 7THE 12TWH 7THE 10TWH 7TwH 9THE 10

TWH 8THE 13TwH 8TWH 6TWH 8TWH 7TWH 9

LOCATION EXT EXT

AV2 +0.00 TEH TECAV2 +0.00 TEH TECAV7 +0.00 TEH TECAV6 +0.00 TEH TECAV5 -0.22 TEC TEHAV6 -0.07 TEC TEHAV6 +0.04 TEH TECAV2 +0.04 TEE TECAV7 +0.18 TEH TECAV4 +0.00 TEH TECAV7 +0.00 TEH TECAVI +0.00 TEH TECAV2 +0.07 TEH TECAV8 +0.02 TEH TECAV4 +0.00 TEH TECAVG +0.00 TEH TECAV7 +0.00 TEH TECAVG +0.00 TEH TECAV8 +0.00 TEH TECAVI +0.00 TEH TECAV2 +0.00 TEH TECAV3 +0.00 TEN TECAV4 +0.02 TEH TECAV5 -0.02 TEH TECAVG +0.04 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAV2 +0.00 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAV5 +0.00 TEH TECAVG +0.00 TEH TECAV7 +0.00 TEH TECAVG +0.02 TEH TECAVI +0.00 TEH TECAV2 +0.00 TEH TECAV3 +0.04 TEH TECAV4 +0.00 TEH TECAVG +0.07 TEH TECAVG +0.00 TEH TECAV7 +0.00 TEH TECAV5 +0.00 TEH TECAV2 +0.00 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAV5 +0.00 TEH TECAVS +0.00 TEH TECAVG +0.00 TEH TECAV5 +0.00 TEH TECAVG +0.00 TEH TECAVG +0.00 TEH TECAV2 +0.00 TEH TECAVI +0.02 TEH TECAVG +0.00 TEN TECAV5 +0.00 TEH TECAV3 +0.00 TEN TECAV2 +0.00 TEH TECAV8 +0.00 TEH TECAV4 -0.24 TEH TECAV3 +0.02 TEH TECAV3 +0.00 TEH TECAVI +0.22 TEH TEC

UTIL 1 UTIL 2 CAL # LEG

60 COLD61 COLD44 COLD44 COLD40 HOT40 HOT20 COLD20 COLD24 COLD29 COLD29 COLD30 COLD30 COLD30 COLD28 COLD28 COLD28 COLD28 COLD28 COLD28 COLD28 COLD26 COLD26 COLD26 COLD24 COLD24 COLD24 COLD45 COLD45 COLD45 COLD45 COLD45 COLD45 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD51 COLD51 COLD50 COLDso COLD53 COLD53 COLD53 COLDSG COLD56 COLD56 COLD56 COLD56 COLD56 COLD58 COLD44 COLD45 COLD

PROBE

610UL610UL610UL610UL610UL6101UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL610UL610UL610UL61OUL610UL61001.

6100UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001.610UL610UL61001.610UL610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL61001.610UL

Page 43: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure I

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 32 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

88 117 0.1789 72 0.17

0.320.18

89 76 0.280.290.520.23

89 78 0.150.180.23

89 80 0.1989 82 0.18

0.220.170.19

89 84 0.220.150.180.150.50

89 86 0.140.430.480.210.290.320.28

89 88 0.280.340.330.36

89 90 0.460.370.170.130.290.21

89 92 0.290.380.140.200.290.21

89 94 0.300.270.260.470.15

89 96 0.120.15

89 98 0.170.190.260.140.460.19

89 100 0.220.210.15

89 102 0.23

DEG CHN

110 P2122 P2120 P2131 P2107 P2110 P2117 P2138 P2129 P2113 P2127 P2109 P2114 P2121 P2121 P2119 P2120 P2130 P2137 P2130 P2127 P265 P2127 P2123 P2127 P2126 P2126 P2117 P2127 P2126 P2111 P2112 P2116 P2128 P2119 P2122 P2129 P2134 P2130 P2126 P2141 P2133 P2140 P2132 P2134 P2121 P2124 P2127 P2151 P2144 P2129 P293 P2131 P2120 P2III P2115 P2130 P2134 P2129 P299 P2139 P2

IND %TW

TKD 8TWD 7TWD 12TWD 7TWD 11TI 11TWD 17TWD 9TKD 6TKD 7TWD 9TWD 8TWD 8TWD 9TWD 7TWD 8TWD 9TWD 7TWD 8TWD 7TWD 17TWD 6

TED 15TWD 16TWD 9T ID 11TED 13T iD 11TED 9T iD 11

T iD 11TED 12TED 14TED 12TWD 6TWD 5TED 10TWD 7T iD 10TED 13TWD 6TWD 8T ID 10

TWD 8T iD 11TED 10TWD 9TED 15TWD 6TWD 5TWD 6TWD 7TWD 7TWD 9

TwD 5TKD 15TWD 7

TwD 8TWD 8

TWD 6TWD 8

LOCATION EXT EXT UTIL I UTIL 2

AV3 -0.04 TEC TEHAV2 +0.00 .TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAV5 +0.00 TEH TECAV6 +0.00 TEH TECAV7 +0.00 TEH TECAV8 +0.11 TEH TECAV3 +0.00 TEH TECAV4 +0.04 TEH TECAV5 +0.00 TEH TECAV7 +0.04 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAV5 +0.00 TEH TECAV7 +0.00 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAV5 +0.00 TEH TECAV6 +0.02 TEH TECAV7 +0.00 TEH TECAVI -0.09 TEH TECAV2 +0.00 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAV5 +0.00 TEH TECAV6 +0.00 TEH TECAV7 +0.00 TEH TECAV7 +0.00 TEH TECAV6 +0.00 TEH TECAV5 +0.07 TEH TECAV4 -0.02 TEH TECAV2 +0.09 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAV5 +0.00 TEH TECAV6 +0.00 TEH TECAV7 +0.00 TEH TECAV2 +0.00 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEE TECAV5 +0.00 TEH TECAV6 +0.00 TEH TECAV7 +0.00 TEH TECAV4 +0.00 TEH TECAVS +0.00 TEH TECAV6 +0.00 TEH TECAV7 +0.00 TEH TECAVI +0.00 TEH TECAV5 +0.20 TEH TECAV6 +0.00 TEH TECAV7 -0.17 TEH TECAV6 -0.17 TEH TECAV5 -0.17 TEH TECAV4 +0.00 TEH TECAV3 +0.00 TEH TECAV2 +0.20 TEH TECAV5 +0.00 TEH TECAV7 +0.00 TEH TECAV6 +0.20 TEH TECAV4 +0.00 TEE TEC

CAL # LEG

40 HOT30 COLD30 COLD30 COLD28 COLD28 COLD28 COLD28 COLD26 COLD26 COLD26 COLD26 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD45 COLD45 COLD45 COLD45 COLD45 COLD45 COLD45 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD51 COLD51 COLD51 COLD51 COLD51 COLD51 COLD53 COLD53 COLD53 COLD54 COLD

PROBE

610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001610UL610UL610UL610UL610UL6101UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61OUL610UL61001L610UL610UL610UL610UL610UL610UL

Page 44: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 33 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN

89 108 0.130.150.170.19

89 112 0.3189 120 0.1490 65 0.1890 69 0.17

0.1990 71 0.20

0.290.23

90 73 0.200.23

90 75 0.1790 77 0.17

0.290.17

90 81 0.150.270.240.24

90 85 0.200.35

90 87 0.260.160.17

90 89 0.160.310.220.170.14

90 91 0.200.210.34

90 93 0.340.200.220.34

90 95 0.230.300.230.160.40

90 97 0.340.270.22

90 101 0.290.230.220.19

90 103 0.220.320.220.20

91 76 0.300.240.220.30

91 78 0.280.320.21

91 80 0.190.22

148 P2*92 P2124 P2132 P2128 P2142 P2110 P2129 P2110 P211 P2129 P2111 P272 P286 P2139 P2124 P2127 P2129 P2120 P2136 P2133 P2127 P2140 P2130 P2130 P2120 P281 P2134 P2124 P2138 P283 P2128 P2116 P2130 P2127 P2135 P2139 P2147 P2129 P2142 P2129 P2139 P2126 P2130 P2153 P2153 P2159 P2137 P2126 P2121 P2151 P2145 P2132 P2144 P2136 P2120 P2126 P2112 P2131 P2130 P2127 P2134 P2132 P2143 P2

IND %TW

TWH 5TWH 6TWH 7TWU 7THU 11TWD 6TWD 8TWD 7TWH 8TWH 8T i 11TH, 9TWH 8

TWO 9TWI 7TWD 7THU 11TWU 7TWU 7THU 11

THU 10THU 10TWU 8THD 13TWD 10

TWH 7TWU 7TWH 6THU 10TWH 8TWH 6TWHU5TWH 7TWH 7TWH 11THU 12TWD 8TWD 8THU 12TWH 9THU 11TWH 9TWH 6THU 13THU 10TWH 8TWH 7THU 10TWH 8TWH 8

TWU 7TWH 8THU 11TWH 8

TWH 8THU 12THU 10TWD 9

THU 12TWH 11THU 12TWH 9TWU 8

TWH 9

LOCATION

AVG +0.00AV5 +0.15AV3 +0.00AV2 +0.00AV2 +0.00AV5 -0.02AV2 -0.02AVG +0.07AV7 +0.15AV4 +0.02AV5 +0.04AVG +0.04AV7 +0.00AV8 +0.00AV7 +0.02AV2 +0.00AV8 +0.00AV3 +0.13AV3 +0.00AV4 +0.04AV5 +0.04AVG +0.00AV5 +0.04AV7 -0.02AVS +0.07AV6 +0.00AV3 +0.00AVG +0.02AV5 +0.00AV4 +0.00AV3 -0.20AV2 +0.24AVS +0.00AV4 +0.00AVG +0.00AV5 +0.00AV4 +0.00AV7 +0.00AVG +0.00AV7 +0.00AVG +0.00AV5 +0.00AV4 +0.00AV2 +0.00AV2 +0.00AV3 +0.00AV5 +0.02AV3 +0.00AV4 -0.24AV5 -0.19AVG -0.04AV3 -0.09AV5 +0.00AVG +0.00AV7 +0.00AV4 +0.00AV5 +0.00AVG +0.00AV7 +0.00AV4 +0.00AV5 +0.00AVG +0.00AV5 +0.00AVG +0.00

EXT EXT

TEH TECTEH TECTEH TECTEH TECTEH TECTEC TEHTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

UTIL 1 UTIL 2 CAL # LEG

60 COLD60 COLD60 COLD60 COLD62 COLD37 HOT19 COLD23 COLD23 COLD30 COLD30 COLD30 COLD29 COLD29 COLD27 COLD27 COLD27 COLD27 COLD25 COLD25 COLD25 COLD25 COLD23 COLD23 COLD44 COLD44 COLD44 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD49 COLD49 COLD49 COLD49 COLD49 COLD49 COLD49 COLD49 COLD49 COLD50 COLD50 COLD50 COLD54 COLD54 COLD54 COLD54 COLD55 COLD55 COLD30 COLD30 COLD27 COLD27 COLD27 COLD27 COLD25 COLD25 COLD25 COLD25 COLD25 COLD

PROBE

6 1031.610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6101L36101UL6101.

610UL610UL610UL61OUL610UL610ULT610ULL61OUL6101L3610UL6101.UL610UL610UL610UL610UL610UL610UL1610UL610UL6101UL6101L3610UL610UL610UL610UL610UL610UL610UL610UL6101L3610UL610UL610UL610UL610131610131610131610131

610131610131610UL1610131610131

610131610131610131610131

6120131.

Page 45: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 34 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

91 82 0.140.150.210.22

91 84 0.400.340.240.58

91 86 0.500.310.340.280.440.31

91 68 0.200.440.190.260.39

91 90 0.130.270.36

91 92 0.330.530.350.350.250.18

91 94 0.320.260.170.350.210.250.14

91 96 0.250.210.270.320.17

91 98 0.310.390.310.26

91 102 0.290.16

0.1691 104 0.24

0.430.290.360.32

91 108 0.130.12

91 110 0.1091 112 0.1891 118 0.1692 67 0.1592 69 0.1492 71 0.17

0.360.29

DEG CHN

132 P2137 P2130 P2119 P2125 P2132 P2127 P2120 P2114 P2113 P2114 P2120 P2113 P2112 P2135 P2113 P2132 P2130 P2119 P2130 P2133 P2132 P2130 P2123 P2140 P2136 P2134 P2148 P2141 P2130 P2143 P2137 P2141 P2143 P2154 P2134 P2131 P2123 P2134 P2137 P2141 P2144 P2148 P2155 P2116 P2107 P282 P2148 P2138 P2145 P2141 P2144 P2142 P298 P279 P2157 P2122 P2136 P2135 P296 P2109 P2107 P2

IND %TW

TWO 6TWO 6

TWO 8TWO 9TWO 14TWO 12TWO 9TWO 18TWO 16TWO 11TWD 12TWD 10TWO 15TWO 11TWO 7TWO 14TWO 7TWD 9

TWO 13TWD 5TWD 9TWO 12TWO 11TWO 16TWO 12TWD 12TWO 9

TWD 7TWO 11TWO 10TWO 7TWO 12TWD 8TWO 9TWO 6TWO 9TWO 8TWO 10TWO 11TWO 7TWO 9TWO 11TWO 9TWO 8TWO 10TWO 6TWO 6TWO 9TWO 14TWO 10TWO 12TWO 11TWO 5TWO 5TWO 4TWO 7TWO 8TWO 6TWO 6TWD 7TWD 13TWD 11

LOCATION EXT EXT UTIL 1 UTIL 2

AV2 +0.02 TER TECAV3 -0.02 TER TECAV6 +0.04 TER TECAV7 +0.02 TER TECAV4 +0.02 TER TECAV5 +0.04 TEN TECAV6 +0.04 TEN TECAV7 +0.02 TER TECAV7 +0.00 TER TECAV6 +0.00 TER TECAV5 +0.00 TEN TECAV4 +0.00 TEN TECAV3 +0.00 TEN TECAV2 +0.00 TEN TECAV8 +0.00 TEN TECAV7 +0.00 TER TECAV6 +0.00 TER TECAV5 +0.00 TEN TECAV4 +0.00 TEN TECAV5 +0.00 TEN TECAV6 +0.00 TEN TECAV7 +0.00 TEN TECAV4 +0.00 TEN TECAV3 +0.00 TER TECAV2 +0.00 TEN TECAV7 +0.00 TEN TECAV6 +0.00 TEN TECAV5 +0.00 TEN TECAV7 +0.00 TEN TECAV6 +0.00 TEN TECAV5 +0.00 TEH TECAV4 +0.00 TEN TECAV3 +0.00 TER TECAV2 +0.00 TEN TECAV8 +0.02 TEN TECAV7 +0.00 TEN TECAV4 +0.00 TEN TECAV3 +0.00 TEN TECAV2 +0.00 TEN TECAVI +0.00 TER TECAV3 +0.00 TEN TECAV4 +0.11 TEN TECAV5 +0.00 TEN TECAV6 +0.09 TEN TECAV4 +0.00 TEN TECAV3 +0.00 TEE TEC

AV2 +0.00 TEN TECAV2 +0.00 TEN TECAV3 +0.00 TEH TECAV4 +0.00 TEN TECAV5 +0.00 TEN TECAV7 +0.00 TER TECAV3 +0.02 TEN TECAV4 +0.02 TEN TECAV5 +0.17 TEN TECAV2 +0.00 TEN TECAV2 +0.00 TEC TERAV4 +0.00 TEN TEC

AV7 +0.07 TEN TECAV4 -0.09 TEN TECAV5 +0.00 TER TECAV7 +0.07 TEN TEC

CAL #

232323232323232344444444444446464646464747474949494949494949494949494949494949495o505o50535353555555555557576061382224292929

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDHOTCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL61011UL610UL61OUL610UL610UL610UL61OUL610UL610UL6101L.610UL610UL610UL61OUL610UL610UL610UL61011L610UL610UL610UL610UL610UL610111610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6101L610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

Page 46: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure I

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 35 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN

92 73 0.19 122 P20.46 123 P20.22 91 P20.40 129 P20.18 131 P2

92 75 0.17 103 P20.16 108 P20.24 116 P20.34 117 P20.38 123 P2

92 77 0.38 Ill P20.46 120 P2

92 79 0.25 129 P292 81 0.42 129 P2

0.53 123 P20.24 123 P20.34 127 P2

92 83 0.28 128 P20.28 127 P20.37 123 P2

92 85 0.19 113 P20.43 125 P20.25 116 P20.15 115 P20.28 127 P2

92 87 0.15 Il P20.24 138 P20.16 127 P20.22 111 P2

92 89 0.14 113 P20.17 97 P20.29 119 P20.19 102 P2

92 91 0.16 120 P20.23 131 P20.27 119 P20.31 123 P20.15 145 P2

92 93 0.26 136 P20.38 127 P20.19 120 P20.38 128 P20.30 135 P2

92 95 0.13 129 P20.42 127 P20.35 132 P20.25 124 P20.38 131 P2

92 97 0.23 124 P20.33 116 P20.46 107 P20.36 124 P2

92 101 0 .18 81 P292 103 0.15 112 P2

0.26 121 P20.23 105 P20.41 110 P20.19 93 P2

92 115 0 .14 108 P293 72 0.22 117 P2

0.21 133 P20.17 133 P20.19 136 P20.22 131 P2

IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG

TWD 8TWD 15TWD 9TWD 14TWD 7TWD 7TWD 7TWD 9TWD 12TWD 13TWD 13TWD 15TWD 10TWD 15TWD 17TWD 9TWD 13TWD 11TWD 11TWD 14TWD 8TWD 15TWD 10TWD 7TWD 11TWD 7TWD 10TWD 7TWD 9TWO 5TWD 6TWD 10TWD 7TWD 6TWD 8TWD 9TWD 10TWD 5TWD 9TWD 13TWD 7TWD 13TWD 11TWO 5TWD 14TWD 12TWD 9TWD 13TWD 9TWD 11TWD 15TWD 12TWD 7TWD 6TWD 10TWD 9TWD 14TWD 7TWD 7TWD 9TWD 8TWD 7TWO 8TWD 9

AViAV3AV4AV6AV7AV3AVsAV6AV7AV8AV3AV6AV3AV3AV4AV5AV6AV2AV5AV6AV2AV3AV4AV5AV7AV3AV5AV6AV7AV6AV5AV4AV3AV2AV4AV5AV6AV8AV2AV3AV4AVSAV6AV2AV3AV4AV5AV6AV5AV4AV3AV2AV3AV7AV6AV4AV3AV2AVSAVIAV3AV4AV6AV8

+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.02+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00-0.18+0.00+0.00+0.00+0.00+0.00+0.07+0.00+0.07+0.00-0.04-0.11+0.00+0.00+0.04+0.00+0.00+0.00+0.00+0.00+0.00

+0.00+0.00+0.00+0.00+0.07+0.00+0.00+0.00+0.00+0.09+0.00-0.13+0.00+0.09-0.13+0.00+0.00

+0.00+0.00+0.00

TEETERTENTERTEHTERTEHTERTERTEETEN

TEETERTERTEETERTEHTEHTERTERTERTERTEETERTEETERTERTEETERTEETEE

TEETERTENTENTERTERTENTERTEETEETEETENTEE

TEETEETENTENTEE

TERTEETEETENTEETEETEETEETEHTECTERTERTERTERTEE

TECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTECTERTECTECTECTECTEC

30303030302828282828282826262626262424242424242424454545454747474747474747474848484848484848484851515151535656565656413030303030

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDHOTCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL61OUL61OUL610UL610UL610UL610UL610UL610UL610UL6100LL61OUL610UL16100L.610UL610UL610UL610UL610UL610UL610UL610UL6101UL610UL610UL610UL610UL610UL610UL61001.

610UL6100LT610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001.610UL610UL610UL610UL610UL610UL610UL610UL.610UL610UL610UL61001.610UL610UL6101UL610UL610UL610UL610UL

Page 47: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 36 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

93 74 0.190.22

93 76 0.180.290.17

93 78 0.330.26

93 82 0.260.16

0.2893 84 0.44

0.460.280.290.56

93 86 0.420.250.330.460.160.220.210.460.240.180.13

93 90 0.270.590.360.200.350.36

93 92 0.340.440.360.210.300.18

93 94 0.380.370.38

93 96 0.300.300.400.25

93 98 0.190.17

93 100 0.230.23

93 102 0.430.190.240.330.23

93 104 0.190.200.17

93 106 0.2693 110 0.13

0.2493 114 0.13

0.1093 128 0.1594 71 0.37

DEG CHN

105 P2102 P2124 P2130 P2128 P2120 P2128 P2129 P2131 P2126 P2128 P2128 P2121 P2115 P2119 P2119 P290 P2128 P2121 P2107 P2133 P2127 P2115 P2133 P2105 P2122 P2128 P2126 P2130 P2124 P2108 P2118 P2116 P2127 P2132 P2133 P2136 P294 P2118 P2130 P2126 P2130 P2135 P2133 P2136 P2119 P2117 P2109 P2115 P2125 P2141 P2127 P2135 P2138 P2114 P2110 P285 P2127 P2118 P2108 P2114 P2141 P2132 P2131 P2

IND %TW

TWD 7TWD 9TWD 7TWD 11TWD 7TWND 12TWD 10TWD 10TWD 7TWD 11TWD 16TWD 16TWD 11TWD 11TWD 18TWD 15TWD 10TWD 13TWD 16TWD 7TWD 8TWD 7TWN) 14TWD 8TWD 6TWD 5TWD 9TWD 17TWD 12TWD 7TWD 11TWD 12TWD 12TWD 14TWD 12TWD 8TWD 11TWD 7TWD 13TWD 13TWD 13TWD 11TWD 11TWD 13TWD 9TWD 7TWD 6TWD 8TWD 9TWD 14TWD 7TWD 9TWO 11TWD 8TWD 8TWD 8TWD 7TWD 10TWD 5TWD 9TWD 6TWD 5TWD 6TWD 13

LOCATION EXT EXT

AVG +0.11 TEN TECAV7 +0.15 TEN TECAV4 +0.00 TEN TECAV5 +0.00 TEN TECAV6 +0.00 TEN TECAV5 +0.04 TEN TECAV7 +0.00 TEN TECAV2 +0.00 TEN TECAV3 +0.00 TEN TECAV7 +0.00 TEN TECAV2 +0.00 TEN TECAV4 +0.00 TEN TECAVS +0.00 TEN TECAV6 +0.00 TEN TECAV7 +0.00 TEN TECAV2 +0.00 TEN TECAV3 +0.00 TEN TECAV4 +0.00 TEN TECAVG +0.00 TEN TECAV7 +0.00 TEN TECAVG +0.04 TEH TECAV5 +0.02 TEN TECAV4 +0.00 TEN TECAV3 +0.02 TEN TECAVI -0.04 TEN TECAV2 +0.00 TEN TECAV2 +0.00 TEN TECAV3 +0.00 TEN TECAV4 +0.00 TEN TECAV5 +0.09 TEN TECAVG +0.00 TEN TECAV7 +0.07 TEN TECAV2 +0.00 TEN TECAV3 +0.00 TEN TECAV4 +0.00 TEN TECAV5 +0.00 TEN TECAVG +0.00 TEN TECAV7 +0.00 TEN TECAV2 +0.00 TEN TECAV3 +0.00 TEN TECAV4 +0.00 TEN TECAV3 +0.00 TEN TECAV4 +0.00 TEN TECAV5 +0.00 TEN TECAV7 +0.00 TEN TECAV5 -0.15 TEN TECAV3 -0.02 TEN TECAV5 +0.00 TEN TECAV3 +0.00 TEN TECAV2 +0.00 TEN TECAV4 +0.00 TEN TECAVS +0.24 TEN TECAVG +0.02 TEN TECAV7 +0.00 TEH TECAV7 +0.07 TEN TECAVS +0.00 TEN TECAV4 +0.17 TEN TECAV3 -0.02 TEN TECAV4 +0.15 TEN TECAVS +0.00 TEE TECAV5 -0.02 TEN TECAVG +0.09 TEN TECAV2 -0.0,2 TEC TENAV7 +0.07 TEN TEC

UTIL 1 UTIL 2 CAL #

29292828282626242424242424242445454545474747474747474747474747474848484848484848484848484851515353545454545456565658595945453330

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDHOTCOLD

PROBE

61OUL610UL610UL610UL6101UL610UL61001.61OUL61001L610UL610UL610UL610UL610UL610UL61001L610UL61001.610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6101UL610UL610UL610U1L610UL610UL610UL610UL610UL61001.610UL610UL610UL610UL610UL610UL610UL61001.610UL61001.610UL610UL610UL610UL610UL610UL610UL610UL610UL

Page 48: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Rev. 0Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1 SG 2A, Page 37 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 OTIL 2 CAL # LEG PROBE

94 73 0.16 102 P2 TWD 7 AV1 +0.00 TEN TEC 29 COLD 610O-L0.23 109 P2 TWD 9 AV2 +0.00 TEN TEC 29 COLD 610UL0.32 96 P2 TWD 12 AV4 +0.00 TEE TEC 29 COLD 61OUL0.29 104 P2 TWD 11 AVS +0.00 TEE TEC 29 COLD 61OUL0.45 116 P2 TWD 15 AVE +0.00 TEE TEC 29 COLD 61OUL0.41 111 P2 TWD 14 AV7 +0.00 TEE TEC 29 COLD 61OUL0.40 112 P2 TWD 14 AV8 +0.00 TEN TEC 29 COLD 610UL

94 75 0.37 123 P2 TWD 14 AV3 +0.00 TEN TEC 27 COLD 610UL0.21 110 P2 TWD 9. AV4 +0.00 TEE TEC 27 COLD 610UL0.27 130 P2 TWD 11 AVS +0.00 TEE TEC 27 COLD 610UL0.26 118 P2 TWD 10 AVG +0.00 TEE TEC 27 COLD 610UL0.26 137 P2 TWD 10 AV7 +0.00 TEE TEC 27 COLD 610UL

94 77 0.17 136 P2 TWD 7 AV3 +0.00 TEE TEC 27 COLD 61OUL0.17 119 P2 TWD 7 AV8 +0.00 TEE TEC 27 COLD 610UL

94 79 0.30 122 P2 TWD 12 AV2 +0.00 TEN TEC 25 COLD 610UL0.16 129 P2 TWD 7 AVE +0.00 TEE TEC 25 COLD 610UL0.18 136 P2 TWD 8 AV7 +0.00 TEN TEC 25 COLD 61OUL

94 81 0.15 147 P2 TWD 7 AV5 +0.09 TEE TEC 25 COLD 61OUL0.23 139 P2 TWD 9 AVG +0.02 TEE TEC 25 COLD 61OUL

94 83 0.26 131 P2 TWD 10 AV2 +0.00 TEE TEC 23 COLD 610UL0.60 123 P2 TWD 19 AV3 +0.04 TER TEC 23 COLD 610UL0.48 119 P2 TWD 16 AV4 +0.00 TEE TEC 23 COLD 610UL0.42 122 P2 TWD 15 AV5 +0.00 TEN TEC 23 COLD 610ULT0.60 124 P2 TWD 19 AV6 +0.00 TEH TEC 23 COLD 610ULT0.41 123 P2 TWD 14 AV7 +0.00 TEE TEC 23 COLD 610UL

94 85 0.40 120 P2 TWD 14 AV4 +0.07 TEE TEC 23 COLD 61OUL0.35 122 P2 TWD 13 AV5 -0.02 TEE TEC 23 COLD 610UL0.30 123 P2 TWD 11 AV6 +0.04 TEN TEC 23 COLD 610ULT0.38 127 P2 TWD 14 AV7 +0.02 TEE TEC 23 COLD 61OUL0.26 127 P2 TWD 10 AVB +0.04 TEH TEC 23 COLD 61OUL

94 87 0.18 121 P2 TWD 7 AV7 +0.00 TEE TEC 44 COLD 61OUL0.27 111 P2 TWD 10 AVE +0.00 TEE TEC 44 COLD 610UL0.27 118 P2 TWD 10 AVS +0.00 TEE TEC 44 COLD 61OUL

94 89 0.40 113 P2 TWD 13 AVE +0.00 TEE TEC 47 COLD 610UL0.44 124 P2 TWD 14 AV5 +0.00 TEE TEC 47 COLD 610UL0.30 124 P2 TWD 10 AV4 +0.00 TEE TEC 47 COLD 610UL0.49 120 P2 TWD 15 AV3 -0.02 TEE TEC 47 COLD 610UL

94 91 0.22 123 P2 TWD 8 AV5 -0.11 TEN TEC 47 COLD 61OUL0.25 121 P2 TWD 9 AV4 +0.00 TEE TEC 47 COLD 610ULT0.23 124 P2 TWD 8 AV2 +0.00 TEE TEC 47 COLD 610UL

94 93 0.27 132 P2 TWD 10 AV7 +0.00 TEN TEC 49 COLD 610UL0.51 128 P2 TWD 16 AVE +0.00 TEE TEC 49 COLD 610UL0.32 135 P2 TWD 11 AV5 +0.00 TEE TEC 49 COLD 610UL0.45 126 P2 TWD 15 AV3 +0.00 TEE TEC 49 COLD 6101LT0.35 137 P2 TWD 12 AV2 +0.00 TEE TEC 49 COLD 61OUL0.16 146 P2 TWD 6 AVI -0.02 TEE TEC 49 COLD 61EUL0.13 iSS P2 TWD 5 AV8 +0.00 TEE TEC 49 COLD 610UL

94 95 0.27 137 P2 TWD 10 AV7 +0.00 TEN TEC 49 COLD 61OUL0.20 141 P2 TWD 8 AVE +0.00 TEE TEC 49 COLD 61OUL0.22 126 P2 TED 8 AV3 +0.00 TEN TEC 49 COLD 610OL0.12 149 P2 TWD 5 AV2 -0.02 TEE TEC 49 COLD 610ULT

94 97 0.29 157 P2 TWD 9 AV4 -0.02 TEE TEC So COLD 61OUL0.22 152 P2 TWD 7 AVE +0.00 TEE TEC 50 COLD 61OUL

94 99 0.24 133 P2 TWD 9 AVE -0.20 TEE TEC 51 COLD 61OUL0.13 106 P2 TED 5 AV5 +0.00 TEN TEC 51 COLD 61OUL0.14 107 P2 TWD 6 AV4 +0.00 TEE TEC 51 COLD 61OUL0.19 110 P2 TED 7 AV3 +0.00 TEE TEC S1 COLD 61OUL

94 109 0.13 121 P2 TWD 6 AV7 +0.04 TEN TEC 45 COLD 610UL0.10 110 P2 TWD 5 AVE +0.02 TEN TEC 45 COLD 610UL

95 72 0.36 118 P2 TWD 13 AV2 +0.07 TEN TEC 29 COLD 610UL0.18 102 P2 TWD 7 AV4 +0.07 TEN TEC 29 COLD 61OUL0.21 103 P2 TED 8 AVS +0.02 TEE TEC 29 COLD 6101)10.15 99 P2 TWD 6 AVE -0.18 TEN TEC 29 COLD 610UL

95 74 0.22 132 P2 TWD 9 AV2 +0.00 TEE TEC 30 COLD 610UL0.24 127 P2 TWD 9 AV5 +0.00 TEE TEC 30 COLD 610UL0.17 136 P2 TWD 7 AVE -0.04 TEN TEC 30 COLD 610UL

Page 49: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 38 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

95 76 0.190.22

95 78 0.200.16

95 80 0.2295 82 0.33

0.300.160.26

95 84 0.330.140.380.260.15

95 86 0.250.360.340.310.460.21

95 88 0.330.330.260.28

95 90 0.190.450.290.290.430.29

95 92 0.490.480.260.300.240.31

95 94 0.230.260.120.44

95 96 0.200.24

95 102 0.300.37

95 106 0.0995 116 0.2096 73 0.35

0.3096 75 0.22

0.1496 77 0.21

0.220.28

96 79 0.280.320.190.360.22

96 81 0.170.17

DEG CHN

129 P2128 P2132 P2134 P2131 P2127 P2135 P2109 P2124 P2120 P2131 P2124 P2121 P2119 P2113 P2114 P2110 P2126 P2119 P2114 P288 P2106 P2137 P275 P2128 P2119 P2124 P2123 P2121 P2132 P2126 P2127 P2137 P2141 P2134 P2136 P2138 P2133 P2113 P2134 P2145 P2142 P2119 P2118 P293 P289 P2118 P2116 P2123 P2124 P2121 P2122 P2119 P2120 P2124 P2122 P2116 P2131 P2117 P2117 P2

IND %TW LOCATION EXT EXT UTIL 1 UTIL 2

TWD 8 AVS +0.00 TEH TECTWD 9 AVG +0.00 TEE TECTWD 8 AV2 +0.00 TEE TECTWD 7 AV7 +0.00 TEN TECTWD 9 AVG +0.00 TEE TECTWD 12 AV4 +0.00 TEE TECTWD 11 AVS -0.04 TEE TECTWD 7 AVG +0.04 TER TECTWD 10 AV7 +0.00 TEH TECTWD 12 AV2 +0.04 TER TECTWD 6 AV3 +0.04 TEE TECTWD 14 AV4 +0.04 TEH TECTWD 10 AVS +0.04 TEE TECTWD 6 AV7 +0.04 TEN TECTWD 9 AV7 +0.00 TER TECTWD 13 AVG +0.00 TEN TECTWD 12 AV5 +0.00 TEN TECTWD 11 AV4 +0.00 TEE TECTWD 15 AV3 +0.00 TEN TECTWD 8 AV2 +0.04 TER TECTED 11 AV7 +0.00 TEE TECTWD 11 AVG +0.00 TEE TECTWD 9 AVg +0.00 TER TECTWD 10 AV4 +0.00 TEE TECTWD 7 AV2 +0.00 TEE TECTWD 14 AV3 +0.00 TEE TECTWD 10 AV4 +0.00 TER TECTED 10 AVS +0.00 TER TECTWD 13 AVG +0.00 TEE TECTWD 10 AV7 +0.02 TEE TECTWD 15 AV7 +0.00 TEN TECTWD 15 AVG +0.00 TEE TECTWD 10 AV5 +0.00 TEE TECTWD 11 AV4 +0.13 TEE TECTWD 9 AV3 +0.00 TEE TECTWD 11 AV2 +0.00 TER TECTWD 9 AV7 +0.00 TEE TECTWD 10 AVG +0.00 TEE TECTWD 5 AV4 -0.02 TEE TECTWD 14 AV3 +0.00 TEE TECTWD 7 AVG +0.00 TEE TECTWD 9 AV5 +0.00 TEE TECTWD 10 AV4 +0.00 TER TECTWD 12 AV2 +0.00 TEE TECTWD 4 AV5 +0.15 TEE TECTED 10 AV2 -0.07 TEC TERTWD 13 AV4 +0.04 TEE TECTED 11 AV5 +0.00 TEE TECTWD 9 AV2 +0.00 TEE TECTED 6 AV3 +0.00 TEE TECTED 9 AV4 +0.00 TEE TECTWD 9 AV5 +0.00 TER TECTWD 11 AVG +0.00 TEE TECTED 11 AV3 +0.00 TEE TECTWD 12 AV4 +0.02 TEN TECTED 8 AV5 +0.02 TEE TECTWD 13 AVG +0.00 TER TECTWD 9 AV7 +0.02 TEN TECTWD 7 AV3 +0.02 TEE TECTWD 7 AV5 +0.04 TEE TEC

CAL #

272725252523232323232323232344444444444446464646474747474747494949494949494949494949535357403030282828282826262626262626

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

6100UL610UL610UL610UL610UL61OUL610UM610LT1SlOUL610UL610ULL610ULT610UL6 10UL6 10UL610UL610UL610UL610UIL610UL610UL610UL61OUL610UL

610UL610UL610UL610UL

G10UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610ULT6 1OUL61OUL610UL610ULT610UL610UL610ULT6 10 UL610UL610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL

Page 50: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 39 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

96 83 0.290.540.440.320.51

96 85 0.180.490.420.370.270.15

96 87 0.260.160.280.430.31

96 89 0.260.500.330.290.650.20

96 91 0.250.350.220.22

96 93 0.200.610.350.190.380.13

96 95 0.280.170.25

96 99 0.3096 101 0.2096 103 0.2397 64 0.1597 72 0.2297 74 0.1597 76 0.17

0.2097 78 0.21

0.2197 80 0.1697 82 0.36

0.160.21

97 84 0.350.370.20

97 86 0.130.480.470.400.140.20

97 88 0.450.220.360.360.190.31

DEG CHN

117 P2124 P2116 P2128 P2130 P2117 P2116 P2124 P2125 P2119 P2109 P2121 P2124 P2121 P2124 P2132 P2119 P2119 P2123 P2103 P2118 P2123 P2111 P2121 P2130 P2121 P2136 P2121 P2117 P2141 P2131 P2135 P2123 P2131 P2131 P2150 P298 P2117 P295 P2117 P297 P2101 P2109 P2122 P2132 P2129 P2113 P2141 P2125 P2126 P2119 P2132 P252 P2122 P2124 P2122 P2133 P2115 P2119 P2122 P2124 P2116 P2112 P2117 P2

IND %TW LOCATION EXT EXT UTIL 1 UTIL 2

TWD 11 AV2 +0.00 TEH TECTWND 18 AV3 +0.00 TEH TECTWD 15 AV4 +0.00 TEH TECTWD 12 AV5 +0.00 TEH TECTWD 17 AVG +0.00 TEH TECTWD 8 AV2 +0.00 TEN TECTWD 17 AV3 +0.00 TEH TECTWD 15 AV5 +0.00 TEH TECTWD 14 AV6 +0.00 TEH TECTWN) 11 AV7 +0.00 TEH TECTWD 6 AV8 +0.00 TEH TECTWD 11 AV2 +0.00 TEH TECTWD 7 AV3 +0.00 TEH TECTWD 11 AV4 +0.00 TEH TECTWN) 15 AV5 +0.00 TEH TECTWD 12 AVG +0.00 TEH TECTWD 9 AV7 +0.07 TEH TECTWD 15 AVG +0.00 TEH TECTWD 11 AV5 +0.00 TEH TECTWD 10 AV4 +0.00 TEH TECTWD 18 AV3 +0.04 TEH TECTWD 7 AV2 +0.22 TEH TECTWD 9 AV7 +0.00 TEH TECTWD 11 AVG +0.00 TEH TECTWD 8 AVS +0.00 TEH TECTWD 8 AV4 +0.00 TEH TECTWD 7 AV2 +0.00 TEH TECTWD 18 AV3 +0.00 TEH TECTWD 12 AV4 +0.00 TEH TECTWD 7 AV5 +0.00 TEH TECTWD 13 AVG +0.00 TEH TECTWD 5 AV7 +0.00 TEH TECTWD 10 AV2 +0.00 TEH TECTWD 6 AV5 +0.00 TEH TECTWD 9 AVG +0.00 TEH TECTWD 9 AVi +0.00 TEN TECTWD 7 AVG -0.17 TEH TECTWD 9 AV2 -0.02 TEH TECTWD 6 AV5 +0.04 TEH TECTWD 9 AV3 +0.00 TEH TECTWD 6 AV7 +0.00 TEH TECTWD 7 AV5 +0.00 TEH TECTWD 8 AVG +0.00 TEH TECTWD 8 AV2 +0.00 TEH TECTWD 9 AV3 -0.02 TEH TECTEN 7 AVG +0.07 TEH TECTWD 13 AV4 -0.02 TEH TECTWD 7 AV5 +0.00 TEH TECTWD 9 AV7 +0.00 TEH TECTWD 13 AV2 +0.00 TEH TECTWD 14 AVS +0.00 TEH TECTWD 8 AVG +0.00 TEH TECTWD 6 AVI +0.00 TEH TECTWE 17 AV2 +0.00 TEH TECTWD 16 AV3 +0.00 TEH TECTWD 15 AV4 +0.00 TEH TECTWD 6 AVS +0.00 TEH TECTWD 9 AV7 +0.00 TEH TECTWD 14 AV7 +0.09 TEH TECTWD 8 AVG- +0.11 TEH TECTWD 12 AV5 +0.00 TEH TECTWD 12 AV4 +0.00 TEH TECTWD 7 AV3 +0.13 TEN TECTWD 10 AV2 +0.04 TEN TEC

CAL #

24

24

24

24

24

24

24

24

24

24

24

45

45

45

45

45

47

47

47

47

47

47

47

47

47

47

48

48

48

48

48

48

48

48

48

50

53

56

20

30

29

28

28

26

26

26

24

24

24

24

24

24

45

45

45

45

45

45

47

47

47

47

47

47

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

G6OUL610UL610UL610UL610UL1610UL61OUL610UL610UL610UL610UL610UL61OUL61oUL610UL61001.610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61UL610UL610UL610UL61001.6100LT610UL610UL610UL610UL61UOOL610UL610UL610UL610UL610UL610LT161001.

610UL610UL610UL610UL)610UL610UL610UL610UL610UL610UL610UL610UL610UL6100L.610UL610UL610UL

Page 51: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 40 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

97 90 0.180.340.300.350.330.30

97 92 0.430.47

0.190.340.300.460.18

97 94 0.160.170.130.470.19

97 96 0.180.260.180.23

97 98 0.300.110.130.18

97 100 0.260.280.25

0.2797 102 0.34

0.260.160.15

97 104 0.140.310.490.420.14

97 106 0.1597 116 0.1598 69 0.1398 73 0.21

0.180.29

98 75 0.160.19

98 77 0.280.200.22

98 79 0.4598 81 0.16

0.240.310.260.180.21

98 83 0.130.480.360.59

DEG CHN

106 P2120 P2128 P2120 P2124 P2126 P2133 P2122 P295 P2121 P2134 P2125 P2130 P2136 P2145 P2139 P2131 P2141 P2122 P2136 P2131 P2135 P2118 P2115 P2124 P2140 P2117 P2I11 P2126 P2129 P2131 P2130 P2151 P2138 P2116 P2122 P2113 P2122 P2136 P2141 P2131 P254 P2112 P2114 P2110 P2123 P2119 P2124 P2130 P2136 P2125 P2129 P2138 P2127 P2136 P2146 P2134 P2130 P2126 P2127 P2125 P2

IND %TW

TWD 7TWD 11

TED) 10TWD 11TWO3 11TWD 10TED 14TWD 15TWD 7TWD 12TWD 11TWD 15TWD 7TWD 6TWD 6TWD 5TWD 15TWD 7

TWD 7TWD 10TWD 7TWD 8TED 11TWD 5TWD 5TED 7TWD 9TWD 10TWD 9TWD 10TWD 11TWD 9TWD 6TWD 6TWD 6TWD 11TWD 16TWD 14TWD 6TWD 6TWD 8TWD 6TWD 8TWD 7TWD 11T•D 7TWD 8TWD 11TWD 8TWD 9TWD 16TWD 7TWD 10TED 12TWD 10TWD 8TWD 9TWD 6TWD 16TED 13TWD 19

LOCATION

AV2 +0.00AV3 +0.00AV4 +0.00AV5 +0.07AV6 -0.02AV7 +0.00AV2 +0.00AV3 +0.00AV4 +0.00AV5 +0.00AVG +0.00AV7 +0.00AV8 +0.00AVI +0.00AV3 +0.00AV4 +0.00AV5 +0.00AV6 +0.00AV2 +0.22AV3 +0,00AV5 +0.00AVG +0.00AV2 +0.07AVG -0.20AV4 -0.15AV3 +0.00AV2 +0.00AV3 +0.00AVS +0.00AVG +0.13AV2 +0.00AV4 +0.00AVG +0.02AV7 +0.00AV5 +0.00AV4 +0.11AV3 +0.00AV2 +0.00AVi +0.00AV2 +0.09AV4 -0.07AV7 +0.24AV2 +0.02AV3 +0.00AV7 +0.00AV2 +0.00AV8 +0.00AV4 +0.00AVS +0.00AVG +0.00AV3 +0.00AV2 +0.02AV3 +0.00AV4 +0.00AV5 +0.00AVG +0.00AV7 +0.00AV2 +0.00AV4 +0.02AVS +0.04AVG +0.02

EXT EXT

TEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEC TEETEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

UTIL 1 UTIL 2 CAL #

47474747474748484848484848484848484848484848515151515353535354545454565656565658402329292927272727272525252525252523232323

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

S6OUL610UL610UL610UL610UL61OUL610ULG10UL610UL610UL610UL610UL610UL3610UL610UL61OUL6101UL610UL61SUL610UL610UL610UL610M1610UL610UL610UL610UL61001,61001L610UL6100UL610UL610UL610UL61001L610UL610UL61001L610UL61OUL610UL61OUL61001L610TUL610UL61001,610UL610UL610UL610UL610UL61001L610UL610UL61OUL610UL610UL610UL61OUL61OUL610U1L

Page 52: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 41 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

98 85 0.120.480.390.180.250.51

98 87 0.230.530.560.590.450.310.35

98 89 0.450.470.640.160.170.42

98 91 0.310.320.230.27

98 93 0.470.190.330.19

98 95 0.300.35

98 99 0.110.20

98 101 0.120.21

98 103 0.360.200.240.22

99 72 0.210.32

99 74 0.2999 76 0.1799 78 0.2099 80 0.1899 82 0.13

0,210.18

99 84 0.140.530.410.31

99 86 0.590.470.520.530.660.570.24

99 88 0.320.390.210.350.400.370.450.36

DEG CHN

92 P2118 P2133 P2127 P2125 P2113 P2142 P2III P2115 P2117 P2124 P2118 P2107 P2130 P2118 P2116 P2103 P2109 P2119 P2123 P2117 P2123 P2127 P2125 P2139 P2126 P2140 P2132 P2123 P267 P294 P2135 P2131 P2144 P2152 P2154 P2146 P298 P2109 P2123 P2121 P2128 P2130 P2127 P2122 P2141 P2114 P2120 P2119 P2129 P2114 P2119 P2114 P2126 P2120 P2114 P2130 P2135 P2122 P2132 P2119 P2113 P2112 P2122 P2126 P2

IND %TW LOCATION

TWD 5 AVI +0.07TWD 16 AV2 +0.04TWD 14 AV3 +0.00TWD 7 AV4 +0.00TWD 10 AVS +0.07TWD 17 AV7 +0.02TWD 9 AV8 +0.00TWD 17 AV7 +0.00TWD 17 AVG +0.00TWD 18 AV5 +0.09TWD 15 AV4 +0.00TWD 11 AV3 +0.00TWD 12 AV2 +0.00TWD 14 AV7 +0.00TWD 14 AV5 +0.00TWD 18 AV3 +0.00TWD 6 AV2 +0.20TWD 6 AVI -0.04TWD 13 AV4 +0.00TWD 10 AV7 +0.00TWD 11 AVG +0.00TWD 8 AV4 +0.00TWD 9 AV2 +0.00TWD 15 AVG +0.00TWI 7 AV5 +0.00TWD 11 AV4 +0.00TWD 7 AV3 +0.00TWD 11 AV4 +0.00TWD 12 AV2 +0.00TWD 5 AVG -0.20TWD 8 AV3 +0.04TWD 5 AV5 -0.17TWD B AVG +0.00TED 12 AV2 +0.00TWO 8 AV3 +0.00TWD 9 AV5 +0.00TWD 8 AV7 +0.00TWD 8 AVG +0.00TED 12 AV7 +0.11TED 11 AVG +0.00TWO 7 AVG +0.00TWD 8 AV8 +0.00TWD 8 AV4 +0.00TWD 6 AV2 -0.02TWD 8 AVS +0.00TWD 7 AV7 +0.04TWD 6 AVI +0.00TWD 17 AV3 +0.00TWD 14 AV4 +0.02TWD 12 AVS +0.04TWD 18 AV7 +0.00TWD 16 AVG +0.00TWD 17 AV5 +0.00TWD 17 AV4 +0.00TWD 19 AV3 +0.00TWD 18 AV2 +0.00TWD 9 AVI +0.00TWD 11 AV8 +0.00TED 13 AV7 +0.00

TWD 8 AVG +0.07TWD 12 AV5 +0.00TWO 13 AV4 +0.00TWD 12 AV3 +0.00TWD 14 AV2 +0.00TED 12 AVI +0.00

EXT EXT UTIL 1 UTIL 2

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

CAL #

2323232323234444444444444447474747474747474747494949494949515154545555555529293027252523232323232323444444444444444646464646464646

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL610UL61OUL610UL61OUL610UL61001.61OUL61UL610UL610UL610ULT610Lt61OUL610UL610U610UL610UL610UL61oUL610UL610UL610UL610UL61oULI1oUL

610UL61001L610UL61oUL610UL610UL610UL610UL61oUL610UL61oUL61OUL61oUL61OUL610UL61oUL61oUL610UL61OUL61oUL610Lt61oUL610UL610ouL61oUL610UL610UL610UL61oUL610UL

Page 53: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 42 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

99 90 0.220.340.210.300.430.62

99 92 0.480.310.280.370.45

99 94 0.310.270.160.44

99 96 0.130.24

99 100 0.330.28

99 102 0.620.350.29

100 73 0.330.23

100 75 0.260.240.180.15

100 77 0.13100 79 0.26

0.23100 81 0.18

0.310.420.460.27

100 83 0.410.340.430.390.17

100 85 0.170.400.340.530.150.60

100 87 0.240.180.400.460.350.48

100 89 0.220.550.410.460.140.110.22

100 91 0.440.270.430.15

DEG CHN

125 P2117 P2118 P2123 P2122 P2126 P2129 P2138 P2135 P2142 P2131 P2140 P2141 P2130 P2119 P2148 P2125 P2147 P2161 P2109 P2122 P2122 P2125 P2146 P2111 P2120 P2112 P2124 P2100 P2132 P2107 P2108 P2122 P2119 P2124 P2121 P2120 P2114 P2120 P2118 P2139 P2110 P2122 P2129 P2118 P2107 P2117 P2107 P2126 P2119 P2124 P2118 P2122 P2115 P2121 P2119 P2123 P281 P2128 P2119 P2126 P2119 P2117 P2114 P2

IND %TW

TWD 8

TWD 11

TWD 7

TWD 10

TWD 13

TWD 18

TWD 15

TWD 11

TWD 10

TWD 13

TWD 14

TWD 11

TWD 10

TWD 6

TWD 14

TWD 5

TWD 9

TWD 10

TWD 8

TWD 18

TWD 12

TWD 10

TWD 12

TWD 9

TWD 10

TWD 9

TWD 7

TWD 6

TWD 6

TWD 10

TWD 9

TWD 7

TWO 11

TWD 15

TWD 16

TWD 10

TWD 15

TWO 13

TWD 15

TWO 14

TWD 7

TWD 7

TWD 14

TWD 13

TWD 18

TWD 7

TWD 19

TWD 10

TWD 8

TWD 15

TWO 16

TWD 13

TWD 16

TWD 8

TWD 16

TWD 13

TWO 14

TWD 5

TWD 4

TWD 8

TWD 14

TWD 9

TWD 13

TWD 6

LOCATION

AV2 +0.00AV3 +0.00AV4 +0.00AVS +0.00AV6 +0.00AV7 +0.00AV7 +0.00AV6 +0.00AVS +0.00AV3 +0.00AV2 +0.00AV8 +0.00AVS +0.00AV4 +0.00AV3 +0.00AV7 +0.06AV3 +0.00AVI +0.00AV7 +0.00AV4 +0.00AV3 +0.00AV2 +0.00AV7 +0.00AV8 +0.00AV2 +0.00AV3 +0.00AV4 +0.00AV7 +0.00AV4 +0.00AV6 +0.00AV7 +0.00AV3 +0.02AVS +0.00AVG +0.00AV7 +0.00AV8 +0.00AV2 +0.00AV4 +0.00AVS +0.00AV6 +0.00AV8 +0.00AVl +0.00AV2 +0.00AV3 +0.00AVS +0.00AVG +0.00AV7 +0.00AV2 +0.00AV3 +0.00AV4 +0.00AVS +0.00AVG +0.00AV7 +0.00AV7 +0.02AVG +0.02AVS +0.00AV4 +0.02AV2 +0.00AVI +0.00AV3 +0,00AVG +0.00AV5 +0.00AV4 -0.09AV3 +0.00

EXT EXT

TEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

UTIL 1 UTIL 2 CAL #

47474747474749494949494949494949495050

535353303028282828282626262626262624242424242424242424244545454545454747474747474747474747

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

6101)1610OL6100L610UL61OUL610OUL6100L610UL61UOL610UL6100L610UL61001,

610UL6101)1

6100L610UL6100)16100L,61OUL6100L,61OUL610OL610UL610UL

61OUL6101)L

610OL6100L610ULL

610ULr610OL1610TJL610UL610UL6101)1,6101)161001.61001,6100U,6101)1,610UL16101UL61OUL

6101)1.610UL610L0610OL61OUL

610OLT

61OUL

6101)L610UL610UL610)L.610UL610UL6100L6100L610UL610OL610UL6101L610L0610UL

Page 54: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure I

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 43 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

100 93 0.200.420.370.130.42

100 95 0.31100 101 0.17100 103 0.14

0.210.400.150.41

101 72 0.25101 74 0.17101 76 0.23101 78 0.18

0.27101 80 0.23

0.350.370.22

101 82 0.340.22

101 84 0.410.300.180.280.32

101 86 0.320.390.420.340.300.51

101 88 0.400.220.220.13

101 90 0.260.130.270.410.230.460.23

101 92 0.380.540.390.290.36

101 94 0.150.210.220.150.13

101 96 0.330.28

101 104 0.140.130.19

101 108 0.13102 71 0.19102 73 0.20

0.430.19

DEG CHN IND %TW LOCATION

135 P2 TWD 8 AV2 +0.00126 P2 TWD 14 AV3 +0.00123 P2 TWD 13 AV4 +0.00139 P2 TND 5 AVS +0.00128 P2 TND 14 AV6 +0.00126 P2 TWD 11 AV2 +0.00118 P2 TND 6 AVG +0.0094 P2 WND 6 AV7 +0.00111 P2 TWD 8 AVG +0.00115 P2 TWD 14 AVS +0.00120 P2 TWD 6 AV3 +0.00114 P2 TWD 14 AV2 +0.00'130 P2 TWD 10 AV8 +0.00104 P2 TWD 7 AV3 +0.07114 P2 TND 9 AVG +0.00118 P2 TND 7 AV3 -0.09120 P2 TND 10 AVG -0.04133 P2 TND 9 AV5 -0.02120 P2 TWD 13 AVG +0.00119 P2 TWD 13 AV7 +0.02124 P2 TWD 9 AV8 +0.09124 P2 TWD 13 AVG +0.00126 P2 TWD 9 AV7 +0.00120 P2 TWD 15 AV2 +0.00122 P2 TWD 11 AV3 +0.00103 P2 TWD 8 AV4 +0.00116 P2 TWD 11 AV5 +0.00126 P2 TWD 12 AVG +0.00120 P2 TWD 12 AVI +0.00117 P2 TWD 14 AV2 +0.00109 P2 TWD 15 AV3 +0.00122 P2 TWD 13 AVS +0.00116 P2 TWD 12 AVG +0.00121 P2 TWD 17 AV7 +0.00125 P2 TWD 13 AV7 +0.02110 P2 TWD 8 AVS -0.04116 P2 TWD 8 AV3 +0.07136 P2 TWD 5 AVI +0.11124 P2 TWD 9 AV2 +0.00120 P2 TWD 5 AV3 +0.00123 P2 TWD 9 AV4 +0.00122 P2 TWD 13 AV5 +0.00117 P2 TWD 8 AVG +0.00125 P2 TWD 14 AV7 +0.02123 P2 TWD 8 AV8 +0.00125 P2 TWD 13 AV2 +0.00132 P2 TWD 17 AV3 +0.00125 P2 TWD 13 AV4 +0.00118 P2 TWD 10 AV5 +0.00131 P2 TWD 12 AVG +0.00140 P2 TWD 6 AVI +0.00121 P2 TWD 8 AV2 +0.00114 P2 TWD 8 AV3 +0.00138 P2 TWD 6 AV8 +0.00155 P2 TND 5 AV7 +0.00124 P2 TWD 11 AV2 +0.00125 P2 TWD 10 AV3 +0.00112 P2 TWD 6 AVG +0.00121 P2 TWD 5 AV5 +0.00126 P2 TND 8 AV2 +0.00115 P2 TWD 6 AV4 +0.02113 P2 TWD 8 AVG +0.00128 P2 TND 8 AV2 +0.02108 P2 TWD 15 AV3 +0.0991 P2 TWD 8 AVG +0.24

EXT EXT UTIL 1 UTIL 2 CAL # LEG

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL6101L3610UL61UOL610UL61OUL610ULT610UL1GlOUL610UL

610UL610UL610UL61001.

610UL610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001L610UL61001610UL610UL6100LT610UL610UL610UL610UL610ULT610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

Page 55: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment I to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 44 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

102 75 0.190.300.150.44

102 81 0.390.320.410.16

102 83 0.140.230.460.33

102 85 0.220.320.450.29

102 87 0.200.520.520.410,420.330.530.25

102 89 0.180.29

0.510.280.170.15

102 91 0.130.410.280.18

102 93 0.180.440.170.380.370.19

102 95 0.170.32

102 115 0.14103 74 0.16

0.400.45

103 76 0.170.330.23

103 78 0.260.160.18

103 80 0.20103 82 0.33

0.150.520.390.23

103 84 0.610.280.170.310.43

DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG

138 P2126 P2128 P2132 P2127 P2126 P2131 P2130 P2141 P2130 P2125 P2122 P2124 P2125 P2114 P2130 P2124 P2119 P2118 P2117 P2116 P2118 P2122 P2125 P2132 P2129 P2122 P2135 P299 P2137 P275 P2126 P2135 P2134 P2149 P2126 P2150 P2131 P2132 P2123 P2148 P2122 P290 P2142 P2119 P2117 P2136 P2115 P2130 P2129 P2145 P2133 P2130 P2118 P2129 P2126 P2125 P2123 P2130 P2141 P2140 P2116 P2114 P2

TWD 8TWD 12TWD 7TWD 16TWD 14TWD 12TWD 15TWD 7TWD 6TWD 9TWD 16TWD 12TWD 9TWO 12TWD 15TWD 11TWD 8

TWD 16TWD 17TWD 14TWD 14TWD 12TWO 17TWD 9TWD 6TWD 10TWD 17TWD 10TWD 6TWD 6TWD 5TWD 14TWD 10TWD 7TWD 7TWD 14TWD 6TWD 13TWD 12TWD 7TWD 7TWD 11TWD 7TWD 7TWD 14TWD 15TWD 7TWD 13TWD 9TWD 10TWD 7TWD 8TWD 8TWD 12TWD 6TWD 17TWD 14TWD 9TWD 19TWD 11TWD 7TWD 12TWD 15

AVGAV7AV3AV4AV3AV4AVSAV6AV2AV3AV5AV6AVIAV5AVGAV7AV8AV7AV6AV5AV4AV3AV2AVIAV6AV5AV4AV3AV2AV7AV3AV4AV5AVGAV7AVGAV5AV4AV3AV2AVGAV2AVSAVIAV2AV3AV5AVGAV7AV4AVSAVG

AV6AV3AVS

AVGAV7AV8AV2AV3AV4AV5AV6

+0.00+0.00+0.00+0.00+0.00+0.02+0.02+0.00-0.04+0.04+0.00+0.04+0.00+0.02+0.02+0.02+0.00+0.00

+0.00+0.00+0.00

+0.00+0.00+0.00+0.00

:0.00

+0.00+0.00+0.24+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00-0.09+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.02+0.04+0.00-0.02-0.02-0.02-0.02+0.00

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEC TENTEH TECTEH TECTEH TECTEH TECTEN TECTEH TECTEH TECTEH TECTEH TECTEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL610UL610UL610UL61O0L610UL610UL610UL61001.610UL610UL1610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61oUL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001L6100L6100L61OUL6100LT610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61OUL61001.610UL

Page 56: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 45 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

103 86 0.530.340.460.320.190.21

103 88 0.170.380.540.200.300.18

103 90 0.150.190.250.130.31

103 92 0.540.400.210.250.590.480.19

103 100 0.21103 104 0.14103 112 0.14

0.30104 71 0.19

0.150.16

104 73 0.300.20

104 75 0.18104 77 0.38

0.23104 79 0.26104 81 0.17104 83 0.25

0.290.550.480.380.28

104 85 0.390.200.200.540.38

104 87 0.290.33

104 89 0.120.400.690.600.160.220.57

104 91 0.270.340.320.320.210.28

DEG CHN IND %TW LOCATION

124 P2 TWO 17 AV7 +0.00113 P2 TWO 12 AVG +0.00120 P2 TWO 15 AVS +0.00114 P2 TWD 12 AV4 +0.0082 P2 TWO 8 AV3 +0.00112 P2 TWO 8 AV2 +0.00138 P2 TWD 6 AV8 +0.00117 P2 TWD 12 AV7 +0.00113 P2 TWO 16 AV6 +0.00121 P2 TWD 7 AVS +0.00118 P2 TWD 10 AV3 +0.00115 P2 TWD 7 AV2 +0.00124 P2 TWD 6 AV2 +0.00123 P2 TWD 7 AV3 +0.02118 P2 TWD 9 AVS +0.09113 P2 TWD 5 AVG +0.00132 P2 TWD 10 AV7 -0.02129 P2 TWD 17 AV7 +0.00134 P2 TWD 13 AVG +0.00138 P2 TWD 8 AVS +0.00136 P2 TWD 9 AV4 +0.00123 P2 TWD 18 AV3 +0.00129 P2 TWO 15 AV2 +0.00143 P2 TWO 7 AVI -0.15160 P2 TWD 6 AVG +0.00134 P2 TWO 5 AV4 +0.26149 P2 TWD 6 AV3 +0.00138 P2 TWO 11 AV2 +0.00122 P2 TWD 8 AV2 +0.00126 P2 TWD 6 AV4 +0.00140 P2 TWO 7 AV5 +0.00128 P2 TWD 11 AV3 -0.07126 P2 TWD 8 AV4 +0.00119 P2 TWO 7 AV2 +0.00118 P2 TWO 13 AV5 +0.00106 P2 TWD 9 AVG +0.00124 P2 TWD 10 AVS +0.04132 P2 TWD 7 AV4 +0.09117 P2 TWO 10 AV2 +0.00115 P2 TWD 11 AV3 +0.00119 P2 TWD 18 AV4 +0.00127 P2 TWD 16 AV5 +0.00124 P2 TWD 14 AV6 +0.00133 P2 TWD 11 AV7 +0.00112 P2 TWO 14 AV2 +0.0090 P2 TWD 9 AV4 +0.00137 P2 TWD 9 AV5 +0.00120 P2 TWO 18 AV6 +0.00123 P2 TWD 14 AV7 +0.00118 P2 TWD 11 AV3 +0.00122 P2 TWD 13 AV7 +0.0073 P2 TWD 5 AV8 +0.11124 P2 TWD 13 AV7 +0.00120 P2 TWO 19 AV4 +0.04124 P2 TWD 17 AV3 +0.0795 P2 TWD 6 AV2 +0.22136 P2 TWD 8 AVI -0.07113 P2 TWD 17 AV5 +0.00118 P2 TWD 10 AVI -0.02122 P2 TWD 12 AV2 +0,00123 P2 TWD 11 AV3 +0.00107 P2 TWD 11 AV4 +0.00134 P2 TWO 8 AV6 +0,00138 P2 TWO 10 AV7 +0.00

EXT EXT UTIL 1 UTIL 2

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

CAL #

44444444444446464646464647474747474949494949494950556161303030303028282826262424242424242424242424454547474747474747484848484848

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL6101)1610014610U)1610UL1610014610014610UL1610U)1

610U1461001461001461001461001461OUL

6101)14610UL61OUL610UL610UL610014610UL610UL610UL610UL610UL610UL610UL610UM6101L)610UL610UL610014610UL0610UL61014UL610UL610UL610UL610UL610UL6101UL610UL610UL610 UL610014610UL610)UL610UL610UL6101UL610UL6101L)610UL610UL610UL610UL610UL610UL610UL610UL610UL

Page 57: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment I to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 46 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

104 93 0.170.430.170.380.310.15

104 95 0.15104 97 0.18104 99 0.29105 72 0.19105 76 0.16105 78 0.16

0.34105 80 0.15

0.260.19

105 82 0.20.0.300.22

105 84 0.200.460.220.150.32

105 86 0.340.310.560.29

105 88 0.610.240.180.240.310.15

105 90 0.400.230.160.320.390.380.18

105 92 0.250.570.240.340.32

105 94 0.330.510.310.300.19

105 98 0.130.14

105 112 0.12105 114 0.14106 71 0.16106 75 0.15106 77 0.17106 79 0.20

0.270.15

106 81 0.310.370.21

DEG CHN

117 P2123 P2122 P2125 P2128 P2133 P2108 P2111 P2150 P2124 P2130 P2118 P2125 P2135 P2126 P2134 P2137 P2125 P2135 P2131 P2117 P2127 P2122 P2127 P2129 P2121 P2118 P2138 P2122 P2130 P2127 P294 P2122 P2114 P2119 P2114 P2117 P2117 P2123 P2120 P2104 P2131 P2128 P2132 P2128 P2135 P2129 P2127 P2126 P2128 P2125 P2119 P299 P2123 P290 P2107 P2147 P2125 P2134 P2129 P2148 P2127 P2130 P2137 P2

IND %TW LOCATION EXT EXT UTIL 1 UTIL 2

TN] 7 AV2 +0.00 TEH TECTWD 14 AV5 +0.00 TEH TECTWD 6 AV4 +0.00 TEH TECTWD 13 AVG +0.00 TEH TECTWD 11 AV7 +0.00 TEH TECTWD 6 AV3 +0.00 TEH TECTWD 6 AV2 +0.00 TEH TECTWN) 7 AVG +0.00 TEH TECTWD 8 AV5 +0.00 TEH TECTWD 8 AV3 +0.00 TEH TECTND 7 AVG +0.00 TEH TECTND 6 AV3 +0.00 TEH TECTWD 12 AVG +0.04 TEH TECTWD 6 AV4 +0.02 TEH TECTND 10 AV5 +0.02 TEH TECTWD 8 AVG -0.02 TEH TECTWD 8 AV2 +0.02 TEH TECTWD 12 AV3 +0.00 TEH TECTWD 9 AVE +0.00 TEH TECTWD 8 AVi +0.00 TEH TECTWD 16 AV3 +0.00 TEH TECT•N] 9 AV4 +0.00 TEH TECTWD 7 AV5 +0.00 TEH TECTN] 12 AVG +0.00 TEH TECTWD 13 AV4 +0.00 TEH TECTND] 12 AV5 +0.00 TEH TECTWD 18 AVG +0.00 TEH TECTWN) 12 AV7 +0.00 TEH TECTN]D 17 AVG +0.00 TEH TECTWD 8 AV5 +0.02 TEH TECTWD 6 AV4 +0.13 TEH TECTWD 8 AV3 +0.04 TEH TECTWD 10 AV2 -0.04 TEH TECTN]D S AVI +0.02 TEE TECTWD 13 AV2 +0.07 TEH TECTWD 8 AV3 +0.00 TEN TECTWD 6 AV4 +0.00 TEH TECTWND 11 AVS +0.07 TEH TECTWD 12 AVG +0.00 TEH TECTWD 12 AV7 +0.02 TEH TECTWD 6 AV8 +0.00 TEH TECTWD 9 AV2 +0.00 TEH TECTWD 17 AV3 +0.00 TEH TECTWD 9 AV4 +0.00 TEH TECTWD 12 AVS +0.00 TEH TECTWN) 11 AVG +0.00 TEH TECTWD 11 AV2 +0.00 TEH TECTWD 16 AV3 +0.00 TEH TECTWD 11 AV4 +0.00 TEH TECTWD 11 AV7 +0.00 TEH TECTWD 7 AV8 +0.00 TEH TECTWD 5 AVE -0.17 TEH TECTWD 6 AV5 -0.17 TEH TECTWD 5 AV2 -0.15 TEH TECTWD 6 AVS +0.07 TEH TECTWD 6 AV2 +0.00 TEH TECTWD 7 AV7 -0.02 TEH TECTWD 7 AVG +0.00 TEH TECTWD B AV5 +0.00 TEH TECTWD 11 AVE +0.00 TEH TECTWD 6 AV7 +0.00 TEH TECTWD 12 AV4 +0.02 TEH TECTWD 14 AVG +0.00 TEH TECTWD 9 AV7 +0.00 TEH TEC

CAL # LEG

48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD51 COLD50 COLD30 COLD28 COLD26 COLD26 COLD26 COLD26 COLD26 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD45 COLD45 COLD45 COLD45 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD51 COLD51 COLD62 'COLD45 COLD29 COLD27 COLD27 COLD25 COLD25 COLD25 COLD25 COLD25 COLD25 COLD

PROBE

610UL

610UL

61OUL610UL610UL610ULT610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610ULT610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UM610UL610UL610UL610UJL610UL610UL610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL610UL610ML610UL610UL

610UL

Page 58: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure I

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 47 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

106 83 0.370.310.570.430.13

106 85 0.620.610.600.390.42

106 87 0.170.350.470.570.400.18

106 89 0.220.580.360.280.180. 110.31

106 91 0.170.340.380.500.420.350.460.16

106 93 0.320.260.15

106 95 0.170.270.320.18

106 97 0.24106 101 0.13107 68 0.14107 70 0.21107 78 0.19107 80 0.32

0.570.220.320.34

107 82 0.260.220.420.540.43

107 84 0.440.330.400.540.18

107 86 0.290.350.14

DEG CHN

120 P2126 P2123 P2131 P2145 P2124 P2122 P2121 P2119 P2122 P2115 P2122 P2127 P2119 P2118 P2128 P2127 P2122 P2114 P2123 P2134 P297 P2126 P2127 P2124 P2122 P2125 P2128 P2121 P2132 P2143 P2136 P2126 P2152 P2150 P2132 P2131 P2142 P2157 P2101 P2123 P2134 P2143 P2230 P2125 P2128 P2126 P2131 P2128 P2132 P2127 P2122 P2124 P2130 P2122 P2128 P2120 P2121 P2117 P2114 P261 P2

IND %TW

TWD 13TWD 12TWD 18TWD 15TWD 6TWD 19TED 19TED 19TED 14TED 15TWD 7TWD 12TED 15TWD 18TWD 14TWD 7TWD 8TWD 17TWD 12TWD 9TWD 6TWD 4T iD 11

TED 6TED 12TED 13TED 16TED 14TWD 12TED 15TWD 6T•D 11TED 10TWD 6TED 7TED 10TED 11

TWD 7TWD 7TWD 5TED 6TED 9TED 8TED 12TWD 19TWD 9TED 12TWD 13TED 10TED 9TED 15TED 18TED 15TED 15TED 12TED 14TED 18TWD 7TWD 11TWD 12TWD 6

LOCATION EXT EXT UTIL 1 UTIL 2

AV2 +0.02 TEE TECAV3 +0.02 TEN TECAV4 +0.04 TEN TECAV6 +0.11 TEE TECAV7 +0.11 TEN TECAV2 +0.02 TEE TECAV4 +0.02 TER TECAV5 +0.04 TEN TECAVE +0.11 TEH TECAV7 +0.04 TEE TECAV8 +0.09 TEN TECAV7 +0.00 TEN TECAV6 +0.00 TEN TECAV4 +0.00 TEN TECAV2 +0.00 TEN TECAVi +0.00 TEN TECAV8 +0.00 TEN TECAVE +0.04 TEE TECAVE +0.00 TEN TECAV4 +0.00 TEN TECAV3 +0.11 TEN TECAV2 +0.22 TEN TECAV7 +0.00 TEE TECAVI +0.00 TEE TECAV2 +0.00 TEE TECAV3 +0.11 TER TECAV4 +0.00 TEE TECAVE +0.02 TEN TECAVE +0.00 TEN TECAV7 +0.00 TEN TECAV8 +0.00 TEN TECAVE +0.00 TEN TECAVE +0.00 TEN TECAV2 +0.00 TEN TECAVE +0.00 TEN TECAV3 +0.00 TEN TECAV2 +0.00 TEN TECAVE +0.00 TEN TECAV2 +0.00 TEN TECAV4 -0.22 TEE TECAV5 +0.04 TEE TECAV3 -0.04 TEE TECAV7 +0.00 TEN TECAV2 +0.00 TEE TECAV3 +0.00 TEN TECAV5 +0.00 TEE TECAVE +0.00 TEN TECAV7 +0.00 TEE TECAV2 +0.02 TEE TECAV3 +0.00 TEE TECAVE +0.00 TEE TECAV6 +0.00 TEN TECAV7 +0.00 TEN TECAV3 +0.00 TEE TECAV4 -0.02 TEE TECAV5 +0.02 TEE TECAVE +0.02 TEN TECAVI +0.02 TEE TEC LARAV7 +0.00 TEN TECAV3 -0.04 TEE TECAV2 +0.00 TEN TEC

CAL #

23

232323232323232323444444444444474747474747474848484848484848494949494949495054223125252525252523232323232323232323444444

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL61OUL610UL610UL610UL61OUL610UL610UL61OUL610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL610UL6101L3610UL61OUL610UL610UL610UL61011.,610UL610UL610UL6101LT610UL61OUL610UL610UL6101L3610UL610UL610UL610UL610UL610L3610UL610UL610UL610UL610UL610UL610UL6101L3610UL610UL610UL610UL610UL610UL610UL6101L3610UL610UL610UL

Page 59: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Rev. 0Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1 SG 2A, Page 48 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CNN IND %TW LOCATION EXT EXT UTIL I. TIL 2 CAL # LEG PROBE

107 88 0.38 124 P2 TWD 12 AV7 +0.04 TEN TEC 46 COLD 61OUL0.70 123 P2 TWD 19 AVG +0.00 TEE TEC 46 COLD 610UL0.28 132 P2 TWD 10 AV5 +0.00 TEN TEC 46 COLD 610UL0.21 110 P2 TWD 8 AV4 +0.00 TEE TEC 46 COLD 610UL0.60 123 P2 TWD 18 AV3 +0.00 TER TEC 46 COLD 610UL0.18 133 P2 TWD 7 AV2 +0.00 TEN TEC 46 COLD 61SUL

107 90 0.24 95 P2 TWD 8 AV2 +0.00 TEN TEC 47 COLD 610UL0.19 128 P2 TWD 7 AV3 +0.00 TEN TEC 47 COLD 610UL0.35 121 P2 TWD 11 AVS +0.07 TEN TEC 47 COLD 61001L0.37 118 P2 TWD 12 AVG +0.07 TEN TEC 47 COLD 610UL0.42 129 P2 TWD 13 AV7 +0.02 TEN TEC 47 COLD 610UL0.14 136 P2 TWD 5 AVG +0.04 TEH TEC 47 COLD 610UL

107 92 0.33 130 P2 TWD 12 AV2 +0.00 TEN TEC 48 COLD 610UL0.65 129 P2 TWD 19 AV3 +0.00 TEN TEC 48 COLD 610UL0.46 125 P2 TED 15 AV4 +0.00 TEE TEC 48 COLD 610UL0.19 134 P2 TWD 7 AVS +0.00 TEN TEC 48 COLD 610UL0.50 129 P2 TWD 16 AVG +0.00 TEN TEC 48 COLD 610UL0.16 133 P2 TWD 6 AV7 +0.00 TEE TEC 48 COLD 61001.

107 94 0.18 137 P2 TED 7 AV5 +0.00 TEE TEC 49 COLD 610UL0.27 133 P2 TWD 10 AV4 +0.00 TEE TEC 49 COLD 610UL0.33 136 P2 TWD 11 AV3 +0.00 TEE TEC 49 COLD 610)UL

107 96 0.21 138 P2 TWD 8 AV7 +0.00 TEE TEC 49 COLD 610UL0.23 136 P2 TWD 9 AVG +0.00 TEE TEC 49 COLD 610UL0.42 132 P2 TWD 14 AV4 +0.00 TEE TEC 49 COLD 610UL0.17 138 P2 TWD 7 AV3 +0.00 TEN TEC 49 COLD 610UL0.20 142 P2 TWD 7 AV2 -0.02 TEN TEC 49 COLD 610UL0.16 151 P2 TWD 6 AVI +0.09 TEN TEC 49 COLD 610UL

107 102 0.24 143 P2 TWD 9 AV3 +0.00 TEN TEC 54 COLD 61001.107 112 0.14 160 P2 TWD 6 AV2 +0.00 TEN TEC 61 COLD 610ULT108 71 0.23 141 P2 TWD 9 AV2 +0.00 TEN TEC 30 COLD 610UL

0.17 141 P2 TWD 7 AV7 +0.00 TEE TEC 30 COLD 610UL108 73 0.26 129 P2 TWD 10 AV3 +0.00 TEN TEC 30 COLD 610M1

0.46 120 P2 TWD 16 AV4 -0.02 TEN TEC 30 COLD 610UL0.24 117 P2 TWD 9 AV5 +0.00 TEE TEC 30 COLD 610ULL

108 75 0.23 122 P2 TWD 9 AV5 +0.00 TEE TEC 28 COLD 610UL0.17 113 P2 TWD 7 AV7 +0.00 TEN TEC 28 COLD 610UL

108 77 0.16 109 P2 TWD 7 AV5 +0.00 TEE TEC 28 COLD 610UL0.26 123 P2 TWD 10 AVG +0.00 TEE TEC 28 COLD 610U.L0.22 120 P2 TWD 9 AV7 +0.00 TEN TEC 28 COLD 610UL

108 79 0.17 127 P2 TWD 7 AVG -0.02 TEN TEC 26 COLD 610ULT108 81 0.26 124 P2 TWD 10 AV5 +0.00 TEN TEC 26 COLD 610UL

0.45 116 P2 TWD 15 AVG +0.00 TEN TEC 26 COLD 610UL0.30 127 P2 TWD 11 AV7 +0.02 TEN TEC 26 COLD 610UL.0.17 132 P2 TWD 7 AV8 +0.02 TEN TEC 26 COLD 610UL

108 83 0.36 116 P2 TWD 13 AV4 +0.00 TEN TEC 24 COLD 610UL0.44 128 P2 TWD 15 AV5 +0.00 TEE TEC 24 COLD 610UL0.51 119 P2 TWD 17 AVG +0.00 TEE TEC 24 COLD 610UL0.25 120 P2 TWD 10 AV7 +0.00 TEN TEC 24 COLD 610DI1

108 85 0.19 120 P2 TWD 8 AVI +0.00 TEN TEC 24 COLD 610UL0.43 117 P2 TWD 15 AV2 +0.00 TEN TEC 24 COLD 610UL0.45 125 P2 TWD 16 AV3 +0.00 TEE TEC 24 COLD 61001.

0.19 123 P2 TWD 8 AV4 +0.00 TEN TEC 24 COLD 610UL0.41 I11 P2 TWD 15 AVG +0.00 TEN TEC 24 COLD 610UL0.25 116 P2 TWD 10 AV8 +0.00 TEN TEC 24 COLD 610UL

108 87 0.14 133 P2 TWD 6 AVl +0.00 TEN TEC 45 COLD 610UL0.37 123 P2 TWD 14 AV2 +0.00 TEN TEC .45 COLD 610UL0.16 95 P2 TWD 7 AV3 +0.00 TEN TEC 45 COLD 610UL0.16 128 P2 TWD 7 AV4 +0.00 TEN TEC 45 COLD 610UL

108 89 0.32 127 P2 TWD 11 AV8 +0.00 TEE TEC 47 COLD 610UL0.45 123 P2 TWD 14 AV7 +0.09 TEN TEC 47 COLD 610M10.68 116 P2 TWD 19 AV5 +0.07 TEN TEC 47 COLD 610UL0.49 117 P2 TWD 15 AV3 +0.04 TEN TEC 47 COLD 610UL0.11 90 P2 TWD 4 AV2 +0.17 TEN TEC 47 COLD 610UL0.47 112 P2 TWD 15 AVG +0.00 TEN TEC 47 COLD 610UL

Page 60: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment I to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 49 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

108 91 0.240.280.600.580.350.430.33

108 93 0.380.130.15

108 95 0.480.370.640.340.410.23

108 99 0.550.35

108 101 0.180.180.17

108 103 0.180.140.11

109 72 0.260.330.320.29

109 74 0.260.250.23

109 76 0.16109 78 0.24

0.570.260.22

109 80 0.150.250.260.16

109 82 0.190.320.310.190.28

109 84 0.260.170.370.34

109 86 0.160.340.130.310.260.610.38

109 88 0.180.440.200.180.40

DEG CHN

128 P2112 P2113 P2115 P2121 P2114 P2127 P2128 P2126 P2123 P2122 P2125 P2123 P2129 P2124 P2119 P2135 P2147 P2101 P2110 P2113 P287 P2127 P285 P2115 P2123 P2130 P2129 P2118 P2104 P2114 P2110 P2134 P2117 P2114 P2122 P2128 P2130 P2121 P2110 P2106 P2121 P2128 P2106 P2127 P2132 P2126 P2123 P2123 P2115 P2108 P269 P2118 P2125 P2121 P2III P2128 P2120 P2103 P2101 P2121 P2

IND %TW LOCATION EXT EXT UTIL 1 UTIL 2

TWD 9 AVl +0.00 TEH TECTWD 10 AV2 +0.00 TEH TECTWD 18 AV3 +0.00 TER TECTWD 18 AV4 +0.00 TEH TECTED 12 AV5 +0.00 TEN TECTWD 14 AV6 +0.00 TEH TECTWD 11 AV7 +0.00 TEN TECTWD 13 AV2 +0.00 TEN TECTW-D 5 AVG +0.00 TEE TECTWD 6 AV7 +0.00 TEN TECTWD 15 AV2 +0.00 TEN TECTWD 13 AV3 +0.00 TEE TECTWD 19 AV4 +0.00 TEN TECTWD 12 AV5 +0.00 TEN TECTWD 14 AV6 +0.00 TEE TECTWD 9 AV7 +0.00 TEN TECTWD 14 AV2 +0.00 TEE TECTWD 10 AV3 +0.00 TEH TECTED 7 AV6 +0.11 TEE TECTWD 7 AV4 +0.00 TER TECTWD 7 AV3 +0.00 TEN TECTWD 7 AV4 +0.00 TEE TECTWD 6 AV3 +0.00 TEE TECTWD 5 AV2 +0.00 TEE TECTWD 10 AV5 +0.09 TEH TECTWD 12 AV6 +0.07 TEE TECTWD 12 AV7 +0.07 TEE TECTWD 11 AV8 +0.04 TEH TECTWD 10 AV5 +0.09 TER TECTWD 10 AV6 -0.31 TEE TECTWD 9 AV7 +0.11 TEE TECTWD 7 AV2 +0.00 TEE TECTED 9 AV2 +0.04 TEE TECTWD 18 AV3 +0.04 TEE TECTWD 10 AV4 +0.04 TER TECTWD 9 AV5 +0.00 TEE TECTWD 6 AV2 -0.02 TEN TECTWD 10 AV3 +0.04 TEE TECTED 10 AV5 +0.02 TEN TECTWD 7 AV6 +0.07 TEE TECTWD 8 AVI -0.02 TEE TECTWD 12 AV2 +0.00 TEE TECTWD 12 AV3 +0.00 TEE TECTWD 8 AV6 +0.00 TEE TECTWD 11 AV7 +0.00 TEE TECTWD 10 AVI +0.00 TEE TECTWD 7 AV4 +0.00 TEN TECTWD 14 AV5 +0.00 TEN TECTWD 13 AV6 +0.00 TEN TECTWD 7 AVI +0.11 TEE TECTWD 13 AV2 +0.00 TER TECTWD 6 AV3 +0.00 TEE TECTWD 12 AV4 +0.00 TEN TECTWD 11 AVG +0.00 TEE TECTED 19 AV7 +0.00 TEN TECTED 14 AV8 +0.00 TEN TECTWD 6 AVB +0.02 TEN TECTWD 14 AV6 +0.00 TEE TECTWD 7 AV3 +0.17 TEN TECTWD 6 AV2 -0.07 TEN TECTWD 13 AV7 +0.00 TER TEC

CAL # LEG

48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD50 COLD50 COLD53 COLD53 COLD53 COLD56 COLD56 COLD56 COLD30 COLD30 COLD30 COLD30 COLD29 COLD29 COLD29 COLD28 COLD26 COLD26 COLD26 COLD26 COLD26 COLD26 COLD26 COLD26 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD45 COLD45 COLD45 COLD45 COLD45 COLD45 COLD45 COLD47 COLD47 COLD47 COLD47 COLD47 COLD

PROBE

610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001.610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61OUL

Page 61: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment I to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 50 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

109 90 0.400.120.390.380.43

109 92 0.140.500.680.400.310.120.15

109 94 0.310.170.23

109 100 0.230.12

109 102 0.240.22

110 71 0.250.17

110 73 0.24110 77 0.25110 79 0.17

0.29110 81 0.17

0.360.32

110 83 0.170.300.36

110 85 0.170.540.290.400.450.580.30

110 87 0.260.390.24

110 89 0.160.140.260.530.680.540.530.20

110 91 0.430.300.560.320..630.21

110 93 0.240.430.530.420.13

DEG

120143127125109142129122132124129140124128125136118114122104122107134146123141128130119133127123115127125120118120126112126135127126121119113113125127128121124126113140129117117153

CHN IND %TW

P2 TWD 13P2 TWD 5P2 TWD 12P2 TWO 12P2 TWD 13P2 TWD 5P2 TWD 16P2 TWD 19P2 TWD 13P2 TWD 11

P2 TWD 5P2 TWD 6P2 TWD 11P2 TWD 7P2 TWD 9P2 TWD 9P2 TWD 5P2 TWD 9P2 TWD 8P2 TWD 10P2 TWD 7P2 TWD 9P2 TWI i0P2 TWD 7P2 TWD 11P2 TWD 7P2 TWD 13P2 TWD 12P2 TWD 7P2 TWD 11P2 TWD 13P2 TWD 7P2 TWD 18P2 TWD 11P2 TWD 14P2 TWD 15P2 TWD 18P2 TWD 11P2 TWD 10P2 TWD 13P2 TWD 9P2 TWD 6P2 TWD 5P2 TWD 9P2 TWD 16P2 TWD 19P2 TWD 16P2 TWD 16P2 TWD 7P2 TWD 14P2 TWD 11P2 TWD 17P2 TWD 11P2 TWD 19P2 TWD 8P2 TWD 9P2 TWD 14P2 TWD 16P2 TWD 14P2 TWD 5

LOCATION

AV2 +0.00AV3 +0.00AV5 -0.02AV6 +0.00AV7 +0.00AV2 +0.00AV3 +0.00AV4 +0.00AVG +0.00AV7 +0.00AVS +0.00AV8 +0.00AV2 +0.00AV3 +0.00AVG +0.00AV7 +0.02AVG +0.13AVS +0.02AV3 +0.00AV2 +0.00AV3 +0.00AV2 +0.00AVG +0.00AV2 +0.00AV3 +0.00AV4 +0.00AV5 +0.00AVG +0.00AVi -0.02AV2 -0.02AV7 +0.04AVI +0.02AV3 +0.11AV4 +0.09AVS +0.09AVG +0.11AV7 +0.02AV8 +0.09AVG +0.00AVS +0.00AV2 +0.00AV8 +0.04AV7 +0.00AVG +0.00AV5 +0.07AV4 +0.00AV3 +0.00AV2 +0.20AVI -0.02AV2 +0.00AV3 +0.00AV4 +0.00AV5 +0.00AVG +0.00AV7 +0.00AVG +0.00AV4 +0.00AV3 +0.00AV2 +0.00AV5 +0.00

EXT EXT

TEN TECTEN TECTEN TECTEE TECTEH TECTER TECTEN TECTEN TECTEW TECTER TECTEN TECTEN TECTEN TECTER TECTEN TECTEW TECTEW TECTEE TECTEN TECTEN TECTEW TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEE TECTER TECTEN TECTEH TECTER TECTEN TECTEN TECTEN TECTEN TECTEE TECTEE TECTER TECTER TECTEW TECTEN TECTER TECTEW TECTER TECTER TECTEH TECTER TECTER TECTER TECTER TECTEE TECTEW TECTER TECTER TECTEN TECTER TECTEN TECTEN TECTER TEC

UTIL I UTIL 2

LAR

CAL #

47

47

47

47

47

48

48

48

484848484848485151535329292927252525252523232323232323232323444444474747474747474748484848484849494949

49

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL

610UL610UL610UL610UL510UL610UL610UL610UL610UL610UL610UL610UL610UL610ULT610UL6 10UL610UL610OLT610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL610ULL6 1 UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

61001.

Page 62: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment I to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 51 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN

110 95 0.250.370.170.460.20

110 103 0.31111 78 0.17

0.1811 80 0.26

0.2411 82 0.27

0.130.23

111 84 0.350.170.480.58

111 86 0.140.220.210.340.350.370.41

11 88 0.620.570.400.520.17

i11 90 0.200.220.240.360.29

111 92 0.220.430.180.500.240.13

11 94 0.200.17

i11 96 0.340.58

111 102 0.200.460.150.16

111 104 0.21Ill 110 0.13112 77 0.18112 79 0.22112 81 0.31

0.47112 83 0.18

0.250.530.260.440.28

112 85 0.210.370.250.480.24

133 P2132 P2148 P2124 P2143 P2135 P2137 P2140 P2128 P2139 P2127 P2121 P2122 P2121 P2138 P2122 P2125 P2141 P2116 P285 P2129 P2117 P2106 P2116 P2117 P2122 P2122 P2119 P2124 P298 P2I11 P2126 P211 P2133 P2129 P2128 P2138 P2129 P2132 P2129 P2131 P2142 P2135 P2124 P2152 P2121 P2150 P2145 P2153 P2115 P2108 P2128 P2117 P2123 P2126 P2129 P2122 P2131 P2122 P2125 P2118 P2127 P299 P2127 P2124 P2

IND %TW

TWD 9TWD 13TWD 6TWD 15TWD 8TWD 11TWD 7TWD 8TWD 10TWD 10

TWD 10TWD 6TWD 9TWD 13TWD 7TWD 16TWD 18TWD 6TWD 9TWD 8TWD 12TWD 12TWD 13TWD 14TWD 18TWD 17TWD 13TWD 16TWD 6TWD 7TWD 8TWD 8TWD 12TWD 10TWD 8TWD 14TWD 7TWD 16TWD 9TWD 5TWD 7TWD 6TWD 12TWD 17TWD 7TWD 15TWD 6TWD 6TWD 8TWD 5TWO 7TWD 9TWD 12TWD 16TWD 8TWD 10TWD 18TWD 10

TWD 15TWD 11TWD 9TWD 14TWD 10TWD 16TWD 10

LOCATION

AV7 +0.00AVG +0.00AV3 +0.00AV2 +0.00AVI +0.00AV2 +0.00AV2 +0.00AV5 +0.00AV5 +0.00AV7 +0.00AVS +0.09AVG -0.02AV7 +0.09AV3 +0.00AV4 +0.00AV5 +0.02AVG +0.02AV8 +0.00AV7 +0.07AVG +0.00AV5 +0.00AV4 +0.00AV3 +0.04AV2 +0.00AV7 +0.11AV5 +0.00AV4 +0.02AV2 +0.00AVlI +0.00AV2 +0.00AV4 +0.11AV5 +0.11

AVG +0.09AV7 +0.09AVI +0.00AV2 +0.00AV3 +0.00AVG +0.00AV7 +0.00AVS +0.00AV3 +0.00AV2 +0.00AV4 +0.00AV3 +0.00AV2 +0.00AV3 +0.00AV5 +0.00AVG +0.00AV3 +0.00AV2 +0.00AVG +0.00AV2 -0.02AVS +0.00AVG +0.00AV2 +0.00AV3 +0.00AV4 +0.00AV5 +0.00AVG +0.00AV7 +0.00AV2 +0.00AV3 +0.00AV4 +0.00AV5 +0.00AVG +0.04

EXT EXT

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TEC

UTIL 1 UTIL 2 CAL #

4949494949552525252523232323232323444444444444444646464646474747474748484848484849494949545454545560282626262424242424242424242424

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL61OUL

610UL610UL610UL61OUL610UL610UL610UL

610UL610UL610UL610UL610UL610UM610UL

610UL610ULT610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610ULY610UL610ULT610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

6100UL

Page 63: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 52 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN

112 87 0.48 118 P20.43 121 P20.16 124 P20.24 133 P20.55 119 P20.48 110 P20.21 114 P2

112 89 0.16 130 P20.28 122 P20.58 121 P20.38 118 P20.56 121 P20.31 124 P20.43 116 P2

112 91 0.25 134 P20.38 127 P20.39 123 P20.33 127 P20.15 121 P2

112 93 0.32 133 P20.28 127 P20.26 127 P20.38 125 P20.18 138 P20.19 127 P2

112 95 0.16 120 P20.42 130 P20.34 119 P20.17 140 P2

112 97 0.22 118 P2112 99 0.36 150 P2

0.29 149 P2112 101 0.18 121 P2112 103 0.15 104 P2

0.14 117 P2113 78 0.25 119 P2

0.23 127 P2113 80 0.19 119 P2

0.22 117 P20.32 113 P20.23 123 P2

113 82 0.27 130 P20.41 122 P20.37 126 P20.41 117 P20.58 120 P2

113 84 0.37 129 P20.18 113 P20.49 116 P20.51 125 P2

113 86 0.24 126 P20.58 117 P20.27 104 P20.29 117 P20.22 131 P20.31 118 P20.59 125 P20.30 105 P2

113 88 0.18 120 P20.21 103 P20.27 115 P20.13 118 P2

IND %TW

TED 17TWD 15TWO 7TWD 10TWO 18TWO 17TWO 9TWD 6TWO 10

TWJ 17TWD 12TWO 16TWO 10

TWO 13TWD 9TWO 13TWO 13TWO 11

TWO 6TW 11TWD 10TWD 10TWO 13TWO 7TWO 7TWO 6TWD 14TWO 12TWO 7

TWDO8

TWO 10TwO 9TWO 7TWO 6TWO 6

TWO 10TWO 9TWO 8TWO 9TWO 12TWO 9TWO 11TWD 15TWO 14TWO 15TWO 19TWO 14TKD 8TWO 17TWO 17TWO 10

TWO 19TWO 11TWD 12TWD 9TWO 12TWO 19TWD 12TWO 6TWO 7TWO 9TWDO5

LOCATION EXT EXT

AV2 +0.02 TEH TECAV3 +0.00 TEH TECAV4 +0.15 TEH TECAVS +0.00 TEH TECAVG +0.00 TEH TECAV7 +0.00 TEH TECAV8 +0.00 TEH TECAV8 +0.00 TEH TECAV7 +0.00 TEH TECAVG +0.04 TEH TECAV5 +0.00 TEH TECAV4 +0.00 TEH TECAV3 +0.04 TEH TECAV2 +0.15 TEH TECAVi +0.02 TEH TECAV2 +0.00 TEH TECAV4 +0.00 TEH TECAVG +0.00 TEH TECAV5 +0.00 TEH TECAV2 +0.00 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAV5 +0.00 TEH TECAVG +0.00 TEH TECAV7 +0.00 TEH TECAVi +0.00 TEH TECAV2 +0.00 TEH TECAVG +0.00 TEH TECAV7 +0.00 TEH TECAV2 -0.11 TEH TECAV2 +0.00 TEH TECAV3 +0.00 TEH TECAV2 +0.00 TEH TECAVS +0.02 TEH TECAV2 +0.00 TEH TECAV3 +0.07 TEH TECAVS +0.02 TEH TECAV3 +0.02 TEH TECAV4 +0.00 TEH TECAVG +0.02 TEH TECAV7 +0.02 TEH TECAV2 +0.00 TEH TECAV3 +0.00 TEH TECAVS +0.00 TEH TECAVG +0.00 TEH TECAV7 +0.00 TEN TECAVi +0.00 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAVG +0.00 TEH TECAVI -0.02 TEH TECAV2 +0.00 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAV5 +0.00 TEH TECAVG +0.00 TEH TECAV7 +0.00 TEH TECAV8 +0.00 TEH TECAVG +0.00 TEH TECAVS +0.04 TEH TECAV3 +0.00 TEH TECAV2 -0.20 TEH TEC

UTIL 1 UTIL 2 CAL # LEG

45 COLD45 COLD45 COLD45 COLD45 COLD45 COLD45 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD51 COLD50 COLD50 COLD53 COLD56 COLD56 COLD26 COLD26 COLD26 COLD26 COLD26 COLD26 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD45 COLD45 COLD45 COLD45 COLD45 COLD45 COLD45 COLD45 COLD47 COLD47 COLD47 COLD47 COLD

PROBE

610UL610UL610UL610UL610UL610UL

610UL610UL610UL610UL610ULT610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610ULT610UL610UJL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610ULL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

610U1.

Page 64: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 53 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

113 90 0.250.260.310.39

113 92 0.190.410.300.310.40

113 94 0.14113 96 0.15

0.19113 104 0.24

0.400.22

114 73 0.280.28

114 77 0.16114 79 0.18114 81 0.25

0.350.23

114 83 0.290.160.310.140.190.32

114 85 0.150.440.270.390.360.41

114 87 0.160.290.420.480.29

114 89 0.300.440.240.460.400.470.41

114 91 0.300.230.420.530.280.18

114 93 0.140.440.230.240.22

114 95 0.20115 74 0.30

0.29115 78 0.23115 80 0.31

0.28

DEG CHU

133 P2114 P2119 P2104 P2136 P2126 P2124 P2124 P2125 P2114 P2122 P2131 P2105 P2109 P299 P2104 P2113 P2129 P2119 P2130 P2131 P2137 P2129 P2137 P2128 P2117 P2128 P2125 P2116 P2125 P2127 P2123 P2125 P2122 P293 P2Il1 P2115 P2112 P2115 P2134 P2120 P2124 P2119 P2119 P2117 P2114 P2115 P2101 P2126 P2121 P2119 P2128 P2148 P2133 P2126 P2143 P2147 P2129 P2128 P2120 P2127 P2126 P2133 P2

IND %TW

TED 9TED 9TWO 10TED 12TWD 7

TED 14TED 11TED 11TWD 13TWO 5TWO 6TWD 7TKD 9TWD 14TED8

TWD 10TED 11TWD 7TWO 8

TWD 10TWO 13TWD 9TED 11TWD 7TED 12TWD 6TWD 8TWD 12TWD 6TWD 15TED 10TWO 14TWO 13TWD 14TWD 6

TWO 11TWD 14TED 16TED 11TED 10TWD 14TWD 8TED 14TWD 13TED 14TWD 13TED 11TWO 8TED, 14TED 16TWD 10TWD 7TWO 6TWD 14TED 8TWO 9TED 8TWO 7

TED 11TED 11TWD 9TWD 12TWD 11

LOCATION EXT EXT

AV2 +0.00 TEH TECAVS +0.00 TEH TECAVG +0.00 TEH TECAV7 +0.07 TEH TECAV7 -0.07 TEH TECAV2 +0.00 TEN TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAV4 +0.00 TEH TECAV3 +0.02 TEH TECAV2 -0.28 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAV3 +0.00 TEH TECAV2 +0.00 TEH TECAV2 +0.00 TEH TECAV2 +0.00 TEH TECAV6 +0.00 TEH TECAV6 +0.00 TEH TECAV2 +0.00 TEH TECAV3 +0.00 TEH TECAV4 +0.02 TEH TECAV2 +0.00 TEH TECAV3 +0.04 TEH TECAV4 +0.00 TEH TECAV5 -0.07 TEH TECAVG +0.04 TEH TECAV7 +0.04 TEH TECAV2 +0.04 TEH TECAV3 +0.07 TEH TECAV4 +0.11 TEH TECAV4 +0.09 TEH TECAV5 +0.11 TEN TECAV7 +0.07 TEH TECAV7 +0.00 TEH TECAV5 +0.04 TEH TECAV4 +0.00 TEH TECAV3 +0.00 TEH TECAV2 +0.00 TEH TECAV2 +0.09 TEH TECAV7 +0.07 TEH TECAV6 +0.00 TEH TECAVS +0.00 TEH TECAV4 +0.00 TEH TECAV3 +0.09 TEH TECAV2 +0.20 TEH TECAV2 +0.00 TEH TECAV4 +0.00 TEH TECAV5 +0.00 TEH TECAV6 +0.00 TEH TECAV7 +0.00 TEH TECAV8 +0.09 TEH TECAV6 +0.00 TEH TECAV6 +0.00 TEH TECAV4 +0.00 TEH TECAV3 +0.00 TEH TECAV2 +0.00 TEH TECAV3 +0.17 TEE TECAV2 +0.00 TEH TECAV3 +0.00 TEH TECAV3 +0.00 TEH TECAV5 +0.00 TEH TECAV6 +0.00 TEH TEC

UTIL 1 UTIL 2 CAL # LEG

47 COLD47 COLD47 COLD47 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD56 COLD56 COLD56 COLD29 COLD29 COLD27 COLD25 COLD25 COLD25 COLD25 COLD23 COLD23 COLD23 COLD23 COLD23 COLD23 COLD23 COLD23 COLD23 COLD23 COLD23 COLD23 COLD44 COLD44 COLD44 COLD44 COLD44 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD49 COLD49 COLD49 COLD49 COLD49 COLD49 COLD30 COLD30 COLD25 COLD25 COLD25 COLD

PROBE

61OUL61OUL610UL610UL610UL610UL61OUL610UL61OUL61OUL61OUL610UL610UL610UL61OUL610UL61OUL610UL610UL610UL610UL61OUL61OUL61OUL6lOUL61OUL61OUL61OUL610UL610OUL610UL610UL610UL61OUL61OUL61OUL61OUL610TJL610UL610UL610ULT610UL610UL610UL610UL610UL6101)L610UL610UL610UL610UL610UL610UL610UL610UL610UL.610UL610TUL610UL610UL6101L1610UL610UL

Page 65: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment I to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 54 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

115 82 0.180.430.380.28

115 84 0.390.480.450.530.320.50

115 86 0.250.59

115 88 0.580.380.210.550.530.20

115 90 0.130.350.180.210.180.18

115 92 0.240.210.490.330.420.20

115 96 0.150.140.17

115 102 0.220.18

115 130 0.16116 75 0.16

0.16116 77 0.18116 79 0.45

0.290.250.24

116 81 0.170.290.36

116 83 0.230.570.550.360.26

116 85 0.190.520.220.560.550.51

116 87 0.120.370.290.490.290.300.25

DEG CHN

124 P2123 P2126 P2129 P2129 P2124 P2124 P2124 P2130 P2129 P2105 P2116 P2123 P2104 P2118 P2118 P2119 P2128 P2116 P2119 P2112 P2118 P2124 P2122 P2144 P2123 P2124 P2120 P2127 P2138 P2155 P2149 P2131 P2138 P2133 P285 P2123 P2132 P2104 P2122 P2117 P2123 P2117 P2108 P2119 P2127 P2120 P2116 P2115 P2126 P2135 P2124 P2126 P2120 P2113 P2120 P2119 P2127 P2124 P2125 P2125 P2119 P2116 P2130 P2

IND %TW

TWD 7TWD 15TWD 13TWD 11TWO 14TWO 16TWD 15TWO 17TWD 12TWD 17TWD 9TWD 18TWD 17TWD 12TWD 8TWD 16TWDOI6TWD 7TWD 5TWD 11TWO, 6TWD 7TWD 7TWO 6TWD 9TWD 8TWO 16TWO 11TWO 14TWD 7TWO 6TWD 5TWD 6TWD 8TWD 7TWD 8TWD 7TWD 7TWD 7TWO 15TWO 11TWD 10TWD 9TWD 7TWD 11TWO 13TWD 9TWD 19TWD 18TWO 13TWD 10TWD 8

TWD 17TWD 9TWD 18TWD 18TWD 17TWD 5TWD 14TWO 12TW• 17TWD 12TWO 12TWD 10

LOCATION EXT EXT

AV2 +0.00 TER TECAV3 +0.00 TEN TECAV5 +0.02 TER TECAVG +0.00 TER TECAV2 -0.02 TEN TECAV3 +0.00 TEN TECAV4 +0.04 TEE TECAV5 +0.00 TEN TECAVG +0.04 TEN TECAV7 +0.07 TEN TECAV3 +0.00 TEN TECAV2 +0.00 TEN TECAV7 +0.04 TEN TECAV5 +0.02 TEN TECAV4 +0.02 TEN TECAV3 +0.00 TEN TECAV2 +0.00 TEN TECAVI +0.00 TEN TECAVI +0.04 TEN TECAV2 -0.04 TEN TECAV4 +0.00 TEN TECAV5 +0.00 TEN TECAVG +0.07 TEN TECAV7 +0.04 TEN TECAV2 +0.00 TEN TECAV3 +0.00 TEN TECAV4 +0.00 TEN TECAV5 +0.00 TEN TECAVG +0.00 TEN TECAV7 +0.00 TEN TECAVG +0.00 TEN TECAV3 +0.00 TER TECAV2 +0.00 TEH TECAV3 +0.00 TEN TECAV4 +0.00 TEN TECAV4 -0.04 TEC TENAV2 +0.00 TEN TECAV3 +0.00 TEN TECAVG +0.00 TEN TECAV2 -0.02 TEN TECAVS +0.00 TEN TECAVG -0.04 TER TECAV7 +0.00 TEN TECAV4 +0.00 TEN TECAV5 +0.02 TEN TECAVE +0.00 TEN TECAVI -0.04 TEN TECAV3 +0.00 TEN TECAV4 +0.00 TEN TECAV5 +0.00 TEN TECAV8 +0.00 TEN TECAVI +0.00 TEN TECAV3 +0.00 TEN TECAV4 +0.02 TEN TECAVS +0.00 TEN TECAVG +0,00 TER TECAV7 +0.00 TEN TECAV2 +0.00 TEN TECAV3 +0.00 TEN TECAV4 +0.00 TEN TECAVS +0.00 TEN TECAVG +0.00 TEN TECAV7 +0.00 TEN TECAV8 +0.00 TEN TEC

UTIL I UTIL 2 CAL # LEG

23 COLD23 COLD23 COLD23 COLD23 COLD23 COLD23 COLD23 COLD23 COLD23 COLD44 COLD44 COLD46 COLD46 COLD46 COLD46 COLD46 COLD46 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD49 COLD49 COLD49 COLD54 COLD54 COLD30 HOT28 COLD28 COLD28 COLD26 COLD26 COLD26 COLD26 COLD26 COLD26 COLD26 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD24 COLD45 COLD45 COLD45 COLD45 COLD45 COLD45 COLD45 COLD

PROBE

610UL610UL610UL610UL610UL610UL610UL610UL61001.610UL610UL610UL610UL610UL61001.610UL61001.

61001.610UL610UL610UL610UL6100L6101.L610UL610.UL610UL61001.610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL6100UL61001.610UL610UL6101UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

Page 66: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment I to Enclosure I

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 55 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

116 89 0.210.320.380.260.600.38

116 91 0.180.210.210.28

116 93 0.220.320.140.270.13

116 95 0.150.32

116 97 0.11117 78 0.27117 80 0.16

0.140.24

117 82 0.250.390.150.470.38

117 84 0.360.310.47

117 86 0.500.350.400.460.590.15

117 88 0.530.270.330.290.22

117 90 0.540.210.410.280.53

117 92 0.350.190.370.30

117 94 0.200.18

118 77 0.19218 81 0.19

0.430.36

118 83 0.280.200.340.440.33

DEG CHN IND %TW LOCATION

126 P2 TWD 7 AV8 +0.11128 P2 TWD 11 AV7 +0.04120 P2 TWD 12 AV5 +0.00122 P2 TWD 9 AV4 +0.00120 P2 TWD 17 AV3 +0.04119 P2 TWD 12 AV2 +0.07122 P2 TWD 7 AV2 +0.00133 P2 TED 8 AV3 +0.00139 P2 TWD 8 AVS +0.00123 P2 TWD 10 AVG +0.00123 P2 TWD 8 AV2 +0.00126 P2 TWD 11 AV3 +0.00137 P2 TED 5 AV4 +0.00137 P2 TED 10 AV5 +0.00124 P2 TWD 5 AVl +0.00131 P2 TWD 6 AV3 +0.28135 P2 TWD 11 AVS +0.00127 P2 TWD 5 AV2 +0.17120 P2 TWD 10 AV3 +0.09135 P2 TED 7 AV2 +0.02121 P2 TWD 6 AV5 +0.07131 P2 TED 9 AVG +0.00114 P2 TWD 10 AVI -0.07124 P2 TED 14 AV2 +0.00115 P2 TWD 6 AV4 +0.00115 P2 TED 16 AV7 +0.00116 P2 TWD 14 AV8 +0.00124 P2 TED 13 AVl +0.02111 P2 TWD 12 AV2 +0.07123 P2 TWD 16 AV5 +0.09119 P2 TWD 17 AV2 +0.00109 P2 TWD 13 AV3 +0.00121 P2 TWD 14 AV4 +0.00117 P2 TWD 16 AV5 +0.00123 P2 TWD 19 AVG +0.00106 P2 TED 7 AV8 +0.04126 P2 TWD 16 AVG +0.02123 P2 TED 9 AV5 +0.04125 P2 TWD 11 AV4 +0.07104 P2 TWD 10 AV3 +0.09126 P2 TWD 8 AV2 +0.04123 P2 TWD 16 AV2 +0.00126 P2 TWD 7 AV3 -0.09123 P2 TWD 13 AVS +0.02119 P2 TWD 9 AVG +0.02123 P2 TWD 16 AV7 +0.04134 P2 TWD 12 AV2 +0.00133 P2 TWD 7 AV3 +0.00131 P2 TWD 13 AVG +0.00131 P2 TWD 11 AV7 +0.00136 P2 TWD 8 AVS +0.00128 P2 TWD 7 AVG +0.00134 P2 TWD 8 AV2 +0.00127 P2 TWD 8 AV3 +0.02127 P2 TWD 15 AVS +0.04132 P2 TWD 13 AVG +0.00128 P2 TWD 11 AV2 +0.00125 P2 TWD 8 AV4 +0.04124 P2 TED 12 AV5 +0.04134 P2 TWD 15 AVG +0.09131 P2 TWD 12 AV7 +0.02

EXT EXT UTIL 1 UTIL 2

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

CAL #

47474747474748484848484848484848

.485126262626262626262623232345454545454547474747474747474747484848484848272525252323232323

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL61OUL61OUL61OUL61OUL61OUL610UL

610UL610UL610UL610tUL

610UL610UL610UL610UL610UL610UL610UJL61OUL610UL610UL610UL610UL610UL610UL610ULL610ULL610UL610UL610UL610UL610UL610UL610UL61OULI610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UIL610UL610UL610UL610UL610UL610TUL610UL610UJL

61OUL610UL610UL610UL610UL

610011

Page 67: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 56 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

118 85 0.280.220.480.610.20

118 87 0.310.450.250.490.400.12

118 89 0.200.160.530.180.710.360.23

118 91 0.470.390.300.400.350.150.13

118 93 0.150.280.32

118 95 0.280.39

118 127 0.210.17

119 72 0.26119 80 0.23119 82 0.27

0.420.430.340.47

119 84 0.330.550.610.48

119 86 0.380.620.620.490.490.61

119 88 0.220.480.22

119 90 0.140.470.400.460.210.670.670.30

119 92 0.410.130.430.43

DEG CHN

136 P2136 P2123 P2119 P2119 P299 P2118 P2119 P2112 P2117 P264 P2139 P2103 P2126 P2114 P2121 P2113 P2138 P2127 P2117 P2128 P2120 P2122 P2134 P2131 P2148 P2135 P2130 P2130 P2135 P2133 P2102 P282 P2132 P2137 P2133 P2128 P2129 P2124 P2126 P2120 P2123 P2121 P2113 P2112 P2122 P2119 P2120 P2114 P2104 P2121 P2133 P2135 P2118 P2113 P2.

105 P291 P2117 P2119 P2122 P2126 P2104 P2127 P2130 P2

IND %TW

TWD 11TWD 9TWD 16TWO 19TWD 8TWO 11TWD 15TWD 9TWD 16TWD 14TWD 5TWD 7TWD 6TWD 16TWD 6TWD 19TWD 12TWD 8TWD 15TWD 13TWD 11TWD 13TWD 12TWD 6TWD 5TWD 6TWD 10TWO 11TWD 10TWO 13TWD 8TWD 6TWD 10TWD 9TWD 11TWD 15TWD 15TWD 13TWO 16TWO 12TWD 18TWD 19TWD 16TWD 13TWD 19TWD 19TWD 16TWO 16TWD 18TWD 8TWD 15TWD 8TWD 5TWD 14TWO 13TWD 14TWD 7TWD 19TWD 19TWD 10TWD 14TWD 5TWD 14TWD 14

LOCATION

AV2 +0.07AV4 +0.02AV5 +0.04AV6 +0.07AV8 +0.09AV6 +0.04AVS +0.04AV4 +0.00AV3 +0.02AV2 -0.04AVi -0.02AV8 +0.07AV7 +0.00AVG +0.09AV4 +0.00AV3 -0.02AV2 +0.00AVI -0.09AV2 +0.00AV3 +0.00AV4 +0.00AV5 +0.00AVG +0.00AV7 +0.00AV8 +0.00AV7 +0.04AVG +0.00AVS +0.00AV3 +0.00AV2 +0.00AV2 -0.07AV7 -0.04AV3 +0.07AVG +0.00AV2 +0.02AV3 -0.02AV4 +0.02AV5 -0.02AV6 +0.00AV2 +0.02AV3 +0.02AV5 +0.09AVG +0.07AV7 +0.00AVG +0.00AV5 +0.00AV4 +0.00AV3 +0.00AV2 +0.00AV7 +0.02AVG +0.07AVI +0.00AVI +0.04AV2 -0 .02AV3 +0.04AV4 +0.04AV5 +0.09AVG +0.02AV7 +0.00AV8 +0.00AV2 +0.00AV4 +0.00AV5 +0.00AVG +0.00

EXT EXT

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEC TEHTEC TEHTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC.TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEN TECTEH TECTEN TEC

UTIL 1 UTIL 2 CAL #

23

23

23

23

23

44

44

44

44

44

LAR 44

47

47

47

47

47

47

47

48

48

48

48

48

48

48

49

49

49

'49

49

33

33

29

25

25

25

25

25

25

23

23

23

23

44

44

44

44

44

44

46

46

46

47

47

47

47

47

47

47

47

48

48

48

48

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDHOTHOTCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL6101L361OUL61OUL610UL610UL61OUL610UL610UL610UL610UL6101L3610UL1610UL6101UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610ULL610UL6101.UL6101.UL610UL610UL6101.UL610LT610UL0610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6101L3610UL610UL610UL610UL610UL610UL61001.

610UL610L01

610UL610UL610UL610UL610UL

Page 68: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment I to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 57 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG

119 96 0.34 130119 102 0.15 128120 81 0.43 119

0.31 1160.17 133

120 83 0.43 1290.23 1350.48 1220.31 126

120 85 0.21 1150.33 1160.45 1210.17 140

120 87 0.19 1130.39 1190.40 1180.37 1310.20 1230.13 120

120 89 0.30 1180.36 1190.45 1170.32 1270.24 i10.35 126

120 91 0.46 1230.25 1270.21 1340.31 1330.18 138

120 93 0.36 1290.21 1260.15 1400.25 1300.21 1360.23 125

120 103 0.23 117121 82 0.36 129

0.20 140121 84 0.23 124

0.20 1290.52 119

121 86 0.53 1100.55 1190.38 1170.32 132

121 88 0.50 1190.70 1200.24 1080.22 1290.41 1160.25 122

121 90 0.20 1030.38 1170.51 1150.36 1170.13 110

121 92 0.33 1300.50 1260.26 1260.25 1310.56 1270.33 133

CHN IND %TW LOCATION

P2 TWD 12 AV2 +0.00P2 TWD 6 AVS -0.02P2 TWD 15 AV5 +0.02P2 TWD 12 AVG +0.04P2 TWED 7 AV8 +0.02P2 TWD 15 AV2 +0.00P2 TWD 9 AV4 +0.00P2 TWD 16 AVG +0.00P2 TWD 12 AV7 +0.00P2 TWD 9 AV3 +0.00P2 TWD 13 AV5 -0.04P2 TWD 16 AVG +0.02P2 TWD 7 AV8 +0.02P2 TWD 8 AVI +0.00P2 TWD 14 AV2 +0.00P2 TWD 15 AV3 +0.00P2 TWD 14 AV7 +0.00P2 TWD 9 AV8 +0.00P2 TWD 6 AVG +0.00P2 TWD 10 AV7 +0.04P2 TWD 12 AVG +0.00P2 TWD 14 AV5 +0.00P2 TWD 11 AV4 +0.00P2 TWD 8 AV3 +0.00P2 TWD 11 AV2 +0.00P2 TWD 15 AV2 +0.00P2 TWD 9 AV3 +0.00P2 TWD 8 AV4 +0.00P2 TWD 11 AV5 +0.00P2 TWD 7 AV7 +0.00P2 TWD 12 AV2 +0.00P2 TWD 8 AV3 +0.00P2 TWD 6 AV4 +0.00P2 TWD 9 AVG +0.00P2 TWD 8 AV7 +0.00P2 TWD 8 AV8 +0.00P2 TWD 9 AV4 +0.00P2 TWD 13 AVG +0.11P2 TWD 8 AV7 +0.04P2 TWD 9 AV3 +0.00P2 TWD 8 AV4 +0.00P2 TWD 17 AVG +0.00P2 TWD 18 AV2 +0.17P2 TWD 18 AV3 +0.13P2 TWD 14 AV4 +0.00P2 TWD 13 AV7 +0.00P2 TWD 15 AV7 +0.13P2 TWD 19 AVG +0.04P2 TWD 8 AV5 +0.00P2 TED 8 AV4 -0.02P2 TWD 13 AV2 +0.04P2 TWD 9 AVI -0.04P2 TWD 7 AVI -0.04P2 TWD 12 AV2 +0.15P2 TWD 15 AV3 +0.02P2 TWD 12 AVG +0.07P2 TWD 5 AV7 +0.02P2 TWD 11 AV2 +0.00P2 TWD 16 AV3 +0.00P2 TWD 10 AV4 +0.00P2 TWD 9 AV5 +0.00P2 TWD 17 AVG +0.00P2 TWD 12 AV7 +0.00

EXT EXT

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

UTIL 1 UTIL 2

LAR

LAR

LAR

CAL *

495426262624242424242424244545454545454747474747474848484848484848484848562525242424454545454747474747474747474747484848484848

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL6100L6100L7

610UL6100L6100L610UL610UL610UL610UL610UL610UL610UL610UL610OUL6101UL610UL610UL61OUL610UL610UL61001.61001610UL6100L.610UL6100LT610UL610UL610UL610UL610UL610UL61UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6101UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL610UL61001.610UL610UL610UL610UL61001.610UL

Page 69: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 58 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG

121 94 0.110.150.17

122 81 0.150.150.210.300.17

122 83 0.170.490.410.180.36

122 85 0.310.350.270.430.490.470.18

122 89 0.140.300.470.290.17

122 91 0.250.630.42

123 72 0.16123 82 0.26

0.550.210.170.260.470.39

123 84 0.410.210.280.26

123 86 0.310.290.450.25

123 88 0.410.44

123 90 0.180.430.530.220.260.540.310.15

123 92 0.190.190.260.36

124 69 0.18124 79 0.17124 81 0.30

0.350.210.22

116 P2124 P2136 P2127 P2121 P2121 P2126 P2106 P2123 P2223 P2120 P2127 P2127 P2128 P2131 P2117 P2120 P2123 P2119 P2119 P2119 P2125 P2123 P2122 P2125 P2122 P2126 P2129 P298 P2115 P2111 P2108 P2119 P2112 P2116 P2109 P2113 P2124 P2136 P2128 P211 P2110 P2124 P284 P2118 P2122 P2124 P2112 P2114 P2103 P2116 P2117 P2122 P2144 P2131 P2136 P2127 P2123 P2142 P2120 P2120 P2118 P2118 P2120 P2

TWT) 4TWT) 6TWD 7TWD 7TWD 6TWD 9TWD 12TWD 7TWD 7TWD 16TWD 14TWD 7TWD 13TWD 12TWD 13TWD 10TWD 15TWD 16TWD 16TWD 7TWD 5TNT) 10TWD 14TWD 10TWD 6TWD 9TWD 19TWD 14TWD 6TWD 10TWD 18TWD 8TWD 7TWD 10TWD 16TWD 14TWD 14TWD 8TWD 11TWD 10TWD 11TWD 11TWD 15TWD 9TWD 13TWD 14TWD 6TWD 13TWD 16TWD 8TWD 9TWD 16TWD 10TWD 5TWD 7TWD 7TwD 10TWD 12TWD aTWD 7TWD 11TWD 13TWD 8TWD 9

AV3 -0.20AVG +0.00AV7 +0.00AV3 +0.02AVE +0.02AVG +0.02AV7 +0.07AV8 +0.02AV2 +0.00AV3 -0.02AV4 +0.04AVG +0.04AV7 +0.02AVI -0.04AV2 +0.04AV4 +0.04AVE +0.09AVG +0.11AV7 +0.06AV8 +0.13AVI -0.09AV2 +0.02AV3 +0.04AVG +0.04AV7 +0.09AV2 +0.00AV4 +0.00AV5 +0.00AV3 +0.11AVi -0.02AV2 -0.02AV3 -0.04AV4 +0.02AV5 +0.00AVG +0.02AV7 +0.00AV2 -0.02AV3 +0.00AV5 +0.02AVG +0.00AV2 +0.02AVE +0.04AVG +0.00AV7 +0.02AVG +0.02AVE +0.04AVI -0.07AV2 -0.22AV3 -0.02AV4 +0.00AV5 +0.07AVG +0.07AV7 +0.07AV8 +0.09AV2 +0.00AV3 +0.00AV5 +0.00AVG +0.00AV7 +0.04AV5 +0.00AV2 +0.00AV5 +0.02AV7 +0.00AV8 +0.02

TEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTE4 TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

LAR

48484825252525252323232323232323232323234747474747484848292626262626262623232323444444444646474747474747474748484848222626262626

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

61001,61001.610UL610UL610UL610UL610UL610UL610UL610UL610UL510UL510UL610UL

G10UL610UL610ULG10UL510UL610UL610UL610UL610UM610ULG10UL,610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

610UL

610UL610UL610UL610UL610UL610UL610UL610UL610UL610UJL610UL610UL6101UL610UL610ULL610UL610UL610UL610UL610UL610UL610UL610UL6100UL

Page 70: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment I to Enclosure I

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 59 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

124 83 0.250.510.240.190.22

124 85 0.40124 87 0.22124 89 0.45

0.490.240.520.560.400.17

124 91 0.370.250.330.21

124 93 0.44124 95 0.19125 72 0.15125 80 0.18

0.28125 82 0.36

0.250.560.24

125 84 0.350.620.380.410.20

125 86 0.330.140.410.22

125 88 0.280.280.150.150.17

125 90 0.280.310.18

125 92 0.260.210.300.53

126 75 0.12126 81 0.23

0.170.19

126 83 0.330.23

126 85 0.560.600.190.38

0.36

0.13

DEG CHN

120 P2115 P2122 P2125 P2113 P2118 P2130 P2117 P2118 P2120 P2120 P2122 P2.119 P2125 P2127 P2128 P2131 P2130 P2127 P2103 P268 P2106 P2112 P2127 P2127 P2126 P2131 P2110 P2115 P2112 P2121 P2124 P2105 P284 P2124 P2127 P2123 P2117 P2116 P2120 P2109 P2104 P2129 P2125 P2131 P2117 P2124 P2127 P2125 P2133 P2144 P2138 P2128 P2107 P2127 P2117 P2132 P2128 P2119 P2117 P2

IND %TW

TWD 10TWD 17TWD 10TWD 8TWD 9TWD 15TWD 9TWD 14TWD 15TWD 8TWO 16TWO 16TWO 13TWD 6TWD 13TWD 9TWD 12TWD 8TWD 14TWD 7TWD 6TWO 7TWD 11TWO 13TWD 10TWD 18TWD 10TWO 13TWO 19TWD 14TWD 15TWD 8TWD 13TWD 6TWD 15TWD 9TWD 10TWD 9TWD 5TWD 6TWD 6TWD 10TWD 10TWD 6TWD 9TWD 8TWD 11TWD 17TWD 5TWD 9TWO 7TWD 8TWD 12TWD 9TWD 18TWD 19TWD 8TWO 14TWD 13TWD 6

LOCATION EXT EXT

AVI +0.00 TEH TECAV4 +0.00 TEH TECAV5 +0.00 TEH TECAVE +0.00 TEH TECAV8 +0.11 TEH TECAVG +0.04 TEH TECAV2 +0.15 TEH TECAV2 +0.15 TEH TECAV3 +0.04 TEH TECAV4 -0.09 TEH TECAV5 +0.00 TEH TECAVG +0.00 TEH TECAV7 +0.04 TEH TECAV8 +0.02 TEH TECAV2 +0.00 TEH TECAV3 +0.00 TEH TECAVS +0.00 TEH TECAVG +0.00 TEH TECAVE +0.00 TEH TECAV3 +0.22 TEH TECAV6 +0.22 TEH TECAV3 +0.02 TEH TECAV4 +0.02 TEH TECAV4 +0.09 TEH TECAVE +0.04 TEH TECAVG +0.00 TEH TECAV7 +0.04 TEH TECAV2 +0.00 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAVE +0.00 TEH TECAV7 +0.00 TEH TECAV2 +0.00 TEH TECAV3 -0.04 TEH TECAV5 +0.07 TEH TECAV7 +0.04 TEH TECAV7 -0.02 TEH TECAVG +0.00 TEH TECAV3 +0.13 TEH TECAV2 +0.17 TEH TECAV5 -0.04 TEH TECAV2 -0.24 TEH TECAV5 +0.00 TEH TECAV7 +0.02 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAV5 +0.00 TEH TECAVG +0.00 TEH TECAV7 -0.15 TEE TECAV4 +0.00 TEH TECAVG +0.04 TEH TECAV7 +0.00 TEH TECAV7 +0.04 TEH TECAV8 +0.07 TEH TECAV3 +0.02 TEH TECAV2 +0.02 TEH TECAV5 +0.13 TEH TECAVG +0.09 TEH TECAV7 +0.11 TEH TECAV4 +0.09 TEH TEC

UTIL 1 UTIL 2 CAL #

242424242424454747474747474748484848484829262625252525242424242445454545474747474747474748484848272525252323232323232323

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

G1OUL610UL610UL61UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610ULT610ULT

610UL6 1OUL610UL610UL

610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61OOL

610UL610ULT610UL610UL610L610UL610UL610UL61UL610UL

61001,610UL61001,61001.61001L61001,

610UL

610UL610UL610UL

61001.61001,

Page 71: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 60 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG

126 87 0.230.460.370.150.28

126 89 0.300.380.220.410.600.280.22

126 91 0.160.130.170.540.450.500.22

126 93 0.17126 95 0.15

0.160.22

126 105 0.19127 78 0.29

0.150.16

127 82 0.220.610.370.410.26

127 84 0.460.390.510.500.56

127 86 0.180.340.42

127 88 0.310.270'.17

127 90 0.230.190.510.560.22

127 92 0.520.370.190.13

127 96 0.15128 67 0.38128 73 0.14128 81 0.40

0.380.20

128 83 0.470.390.250.250.20

110 P2I11 P2121 P2102 P2107 P2127 P2119 P2120 P2123 P2123 P2127 P2109 P2114 P2136 P2128 P2121 P2128 P2130 P2129 P2122 P2149 P2144 P2132 P2140 P2118 P299 P2117 P2107 P2123 P2125 P2119 P2125 P2128 P2128 P2124 P2116 P2122 P286 P2114 P2109 P2115 P2115 P2116 P2114 P2112 P2123 P2120 P2119 P2129 P2132 P2142 P2147 P2137 P2125 P284 P2115 P2120 P2137 P2120 P2124 P2127 P2114 P2131 P2

TWD 9TED 15

TWD 13TWD 6TWD 10TWD 10TWD 12TWD 8TWD 13TWD 17TWD 10TWD 8TWD 6TWD 5TWD 7TWD 17TWD 15TWD 16TWD 8TWD 7TWD 6TWD 6TWD 8TWD 7TWD 11TWD 7TWD 7TWD 9TWD 19TWD 13TWD 14TWD 10TWD 16TWD 14TWD 17TWD 17TWD 18TWD 7TWED 12TWD 14TWD 11TWD 9TWD 6TWD 8TWD 7TWD 15TWD 16TWD 8TWD 16TWD 13TWD 7TWD 5TWD 6TWD 14TWD 6TWD 14TWD 14TWD 8TWD 16TWD 14TWD 10TWD 10TWD 8

AV7 +0.07AVG +0.13AV5 +0.13AV3 +0.07AV2 +0.02AVI -0.07AV2 +0.22AV4 +0.02AV5 +0.04AVG +0.02AV7 +0.09AV8 +0.11AV2 +0.00AV3 -0.18AV4 +0.00AV5 +0.00AVG +0.00AV7 +0.00AV8 +0.00AV2 -0.09AV8 +0.11AV3 +0.00AV2 +0.00AV3 +0.00AV7 +0.00AV8 +0.00AVG +0.13AV3 +0.04AV4 +0.00AV5 +0.00AV7 +0.02AV8 +0.04AV2 -0.02AV3 +0.02AV4 +0.07AVG +0.04AV7 +0.00AV8 +0.00AV7 +0.00AVG +0.00AV3 -0.02AV2 +0.00AVI -0.04AVI -0.07AV2 -0.13AVG +0.00AV7 +0.04AV8 +0.07AV2 +0.00AV3 +0.00AVG +0.00AV7 +0.00AVI +0.00AV3 -0.09AVG +0.24AVG +0.00AV7 +0.00AV8 +0.00AV2 +0.00AV3 +0.00AV4 +0.00AVG +0.00AV7 +0.00

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

4444444444474747474747

474848484848484849494949552525252626262626

23232323234444444646464747474747

4848

4848

4922

302626262424242424

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL61UL610UL610UL610UL610UL610UL610ULG6OUL610UL6100UL610UL61OUL610UL610UL610UL1610UL610UL610UL610UL610UL610UL610UL6100L610UL610UL610UL61001.610UL610UL610UL610UL610UL610UL6100L610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001.610UL610UL61001.

610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

Page 72: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment I to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 61 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN

128 85 0.380.570.35

128 87 0.310.160.130.460.530.17

128 89 0.180.300.690.440.23

128 91 0.390.200.160.490.530.26

128 93 0.160.130.250.16

128 95 0.15129 80 0.15129 82 0.37

0.590.330.32

129 84 0.610.300.180.45

129 88 0.31129 90 0.46

0.180.200.260.16

129 92 0.360.320.270.340.23

129 94 0.160.14

130 67 0.250.40

130 81 0.170.26

130 83 0.290.360.230.27

130 85 0.170.26

130 87 0.170.450.570.210.13

126 P2119 P2120 P2113 P288 P2108 P2121 P2121 P2124 P2131 P2113 P2122 P2127 P2125 P2118 P2129 P2126 P2120 P2131 P2132 P2128 P2124 P2121 P2113 P2119 P2125 P2131 P2122 P2130 P2125 P2114 P2128 P2131 P2129 P2125 P2103 P294 P2119 P2130 P2106 P2129 P2133 P2133 P2136 P2124 P2126 P279 P2134 P2123 P2139 P2116 P2118 P2125 P2125 P2121 P2109 P2123 P2137 P2120 P2115 P2101 P2116 P2

IND %TW

TWD 14TED 19TED 13TWJ 12TWD 7

TWD 6TWD 16TWD 18TWD 7TWD 6TWD 10TWD 19TED 14TWD 8T•D 13TWD 8TWD 6TWD 16TWD 17TWD 10TWD 6TWD 5TWD 9TWD 6TWD 6TWD 6TWD 14TWD 19TWD 12TWD 12TWD 19TED 12TWD 8TWD 16TWD 10TWD 14TWD 7TWD 7TWD 9TWD 6TWD 12TWD 11TWD 10TED 12TWD 8

TWD 6TWD 5TWD 10TED 14TWD 7

TWD 10TED 11TED 13TWD 9TWD 10TWD 7TWD 10TWD 7TWD 15TWD 18TWD 8TWD 5

LOCATION

AVS +0.00AVG +0.00AV7 +0.00AV2 +0.02AV3 +0.00AV4 +0.00AVS +0.00AVG +0.00AV7 +0.00AV3 +0.07AV5 +0.04AVG +0.04AV7 +0.09AV8 +0.09AV2 +0.00AV3 +0.00AV4 +0.00AVS +0.00AVG +0.00AV7 +0.00AV2 +0.00AV6 +0.00AV7 +0.00AV8 +0.00AV2 +0.22AV7 +0.02AV3 +0.04AV5 +0.00AVG +0.02AV7 +0.04AV2 +0.00AV3 +0.00AV4 +0.00AVG +0o00AV7 +0.07AV2 -0.24AV4 -0.02AVS +0.00AV7 +0.02AV8 +0.09AV2 +0.00AV3 +0.00AV4 +0.00AV6 +0.00AV7 +0.00AV2 +0.00AV3 +0.00AV2 +0.02AV3 +0.02AV2 -0.02AV5 +0.02AV3 -0.04AV4 +0.02AVG +0.04AV7 +0.04AV4 +0.04AV5 +0.11AV7 +0.07AVG +0.07AV5 +0.13AV4 +0.09AV2 +0.02

EXT EXT

TEE TECTEE TECTEE TECTEN TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEN TECTEN TECTER TECTEE TECTEE TECTEN TECTEE TECTEE TECTEE TECTEE TECTEE TECTEN TECTEN TECTEN TECTEN TECTEN TECTEE TECTEN TECTEE TECTEE TECTEE TECTEE TECTEN TECTEN TECTE- TECTEE TECTEE TECTEE TECTEN TECTEN TECTEE TECTEN TECTEN TECTEE TECTEE TECTEE TECTEE TEC

UTIL 1 UTIL 2 CAL # LEG

24 COLD24 COLD24 COLD45 COLD45 COLD45 COLD45 COLD45 COLD45 COLD47 COLD47 COLD47 COLD47 COLD47 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD26 COLD25 COLD25 COLD25 COLD25 COLD24 COLD24 COLD24 COLD24 COLD47 COLD47 COLD47 COLD47 COLD47 COLD47 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD21 COLD21 COLD25 COLD25 COLD23 COLD23 COLD23 COLD23 COLD23 COLD23 COLD44 COLD44 COLD44 COLD44 COLD44 COLD

PROBE

610UL6100L610UL610UL610UL610UL6100L610O-L610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001.

610UL61001.61001L610UL610UL610UL61001.610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6100L6100L610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

Page 73: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 62 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN IND %TW

130 89 0.15 130 P2 TWD 60.19 112 P2 TWD 70.14 124 P2 TWD 5

130 91 0.38 115 P2 TWD 130.13 107 P2 TWD 5

130 93 0.22 142 P2 TWD 80.44 136 P2 TWD 140.33 134 P2 TWD ii

130 95 0.34 138 P2 TWD 120.17 145 P2 TWD 6

130 103 0.45 133 P2 TWD 14131 74 0.22 121 P2 TWD 9131 78 0.16 88 P2 TWD 7131 82 0.16 130 P2 TWD 7

0.23 127 P2 TWD 9131 84 0.31 119 P2 TWD 12

0.46 124 P2 TWD 160.21 108 P2 TWD 80.44 121 P2 TWD 15

131 86 0.22 102 P2 TWD 80.21 83 P2 TWD 8

131 88 0.19 126 P2 TWD 70.22 125 P2 TWD 80.20 118 P2 TWD 7

131 90 0.25 127 P2 TWD 90.27 108 P2 TWD 90.55 113 P2 TWD 160.51 124 P2 TWD 150.18 108 P2 TWD 6

131 92 0.41 126 P2 TWD 140.27 118 P2 TWD 100.22 134 P2 TWD 8

131 94 0.25 141 P2 TWD 9132 67 0.28 128 P2 TWD 11132 69 0.16 132 P2 TWD 7

0.16 135 P2 TWD 7132 81 0.22 126 P2 TWD 9

0.17 111 P2 TWD 7132 83 0.36 116 P2 TWD 13

0.21 122 P2 TWD 90.39 125 P2 TWD 14

132 87 0.14 122 P2 TWD 6132 89 0.40 125 P2 TWD 13

0.19 134 P2 TWD 70.23 130 P2 TWD 8

132 91 0.35 125 P2 TWD 120.57 118 P2 TED 170.38 121 P2 TWD 130.22 126 P2 TWD 80.56 126 P2 TWD 170.30 139 P2 TWD 11

132 93 0.21 132 P2 TWD 80.26 127 P2 TWD 100.17 138 P2 TWD 70.19 133 P2 TWD 7

133 74 0.12 97 P2 TWED S133 82 0.24 105 P2 TWD 10

0.42 129 P2 TWD 150.37 127 P2 TWD 140.41 117 P2 TWD 150.31 123 P2 TWD 120.16 130 P2 TWD 7

LOCATION

AV4 +0.02AV7 +0.07AV8 +0.07AV2 +0.00AV3 +0.00AV4 +0.09AV3 +0.00AV2 +0.00AV6 +0.00AV2 +0.00AV4 -0.06AV2 +0.00AV6 +0.00AV6 +0.00AV7 +0.00AV3 +0.07AV5 +0.09AV6 +0.11

AV7 +0.04AV3 -0.02AV7 +0.13AV5 +0.00AV4 +0.00AV3 +0.00AVI -0.09AV2 -0.26AV5 -0.02AV6 -0.07AV7 +0.11AV2 +0.00AV3 +0.00AV7 +0.00'AV3 +0.00AV3 -0.02AV6 +0.13AV7 +0.13AVG +0.02AV7 +0.09AV5 +0.00AVG +0.00AV7 +0.00AV6 -0.02AV2 -0.11AV3 +0.07AV7 +0.15AV2 +0.00AV3 +0.00AV4 +0.00AV5 +0.00AVE +0.00AV7 +0.00AV3 +0.00AV4 +0.00AV5 +0.00AV7 +0.00AVE +0.00AV3 -0.04AV4 +0.00AV5 +0.00AVG +0.02AV7 +0.13AV8 +0.07

EXT EXT

TEE TECTEN TECTEE TECTEH TECTEE TECTEE TECTEE TECTEE TECTEH TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEH TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEN TECTEE TECTEE TECTEE TECTEE TECTEE TECTEH TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TEC

UTIL 1 OTIL 2 CAL # LEG

47 COLD

47 COLD47 COLD48 COLD48 COLD49 COLD49 COLD49 COLD49 COLD49 COLD5S COLD55 COLD

27 COLD25 COLD26 COLD26 COLD23 COLD23 COLD23 COLD23 COLD44 COLD44 COLD46 COLD46 COLD46 COLD47 COLD47 COLD47 COLD47 COLD47 COLD48 COLD48 COLD48 COLD49 COLD22 COLD22 COLD22 COLD26 COLD26 COLD24 COLD24 COLD24 COLD45 COLD47 COLD47 COLD47 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD48 COLD28 COLD25 COLD25 COLD25 COLD25 COLD25 COLD25 COLD

PROBE

610UL610UL

610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

•610UL610UL610UL610UL610UL610UL610UL610UL610UL610ULT610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

610U1.

Page 74: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 63 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

133 84 0.180.180.22

133 86 0.270.27

133 90 0.270.390.500.32

133 92 0.480.300.250.410.20

133 94 0.220.14

133 96 0.21134 73 0.15134 81 0.24134 91 0.27

0.110.170.410.200.14

135 82 0.250.500.340.520.21

135 84 0.460.47

135 88 0.220.170.170.20

135 90 0.500.150.300.35

135 92 0.330.230.400.26

136 83 0.12136 85 0.15

0.12136 91 0.22

0.180.36

136 93 0.200.260.14

137 82 0.330.430.16

137 84 0.290.170.48

DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG

124 P2127 P2128 P2119 P2128 P2116 P2106 P2118 P2120 P2123 P2127 P2131 P2124 P2134 P2122 P2123 P2112 P274 P2127 P2130 P2110 P2139 P2123 P2130 P2153 P2127 P2125 P2121 P2120 P2132 P2114 P2127 P2127 P2136 P2107 P2136 P2121 P299 P2136 P2138 P2133 P2129 P2128 P2135 P2121 P2110 P294 P2123 P2116 P2118 P2113 P2102 P2116 P2126 P2125 P2121 P2136 P2134 P2129 P2

TWD 8TWD 8TWD 9TWD 11TWD 11TWD 9TWD 12TWD 15TWD 11TWD 15TWD 11TWD 9TWD 14TWD 8TWD 8TWD 5TWD 8TWD 6TWD 9TWD 10TWD 5TWD 7TWD 14TWD 8TWD 6TWD 9TWD 16TWD 12TWD 17TWD 8TWD 15TWD 15TWD 8TWD 7TWD 7TWD 8TWD 16TWD 6TWD 11TWD 12TWD 12TWD 9TWD 14TWD 10TWD 6TWD 7TWD 6TWD 9TWD 8TWD 14TWD 8TWD 11TWD 6TWD 12TWD 14TWD 6TWD 11TWD 7TWD 16

AV3AV4AV6AV2AV7AVIAV2AV4AV7AV2AV3AV5AV6AV7AVSAV6AV2AV6AV6AV2AV3AV5AV6AV7

AV8AV2AV3AVGAV7AV8AV2AV5AV3AV5AV6AV7AV2AV5AV6AV7AV2AV3AVSAV7AV3AV2AV7AV6AV3AV2AV3AV6AV7AV6AV7AV5AV5AV6AV7

+0.11

+0.02-0.11+0.04+0.07-0.04-0.20-0.09+0.04+0.00+0.00+0.00+0.00

+0.00+0.00+0.00-0.26+0.00+0.00+0.00-0.02-0.02+0.02+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.04+0.02+0.00-0.02+0.15+0.07+0.07-0.22-0.07+0.02+0.09-0.04+0.00+0.02+0.11+0.04-0.07+0.02

+0.09+0.07+0.00+0.00+0.00+0.00+0.00+0.00

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

LAR

LAR

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL610UL610UL610UL61OUL610UL61OUL610TUL610UL610UL610UL610UL610L3610UL161OUL61OUL610UL61OUL61OUL61OUL

610UL610UL610UL610UL610UL610UL610UL61OUL610UL61OUL610UL610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL61OUL61001L61OUL6103L610T1L610UL61001.61001.610UL610UL610UL610L610UL6100L610UL610UL

Page 75: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 1 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2A, Page 64 of 64

SG 2A Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

137 88 0.240.18

137 90 0.340.400.530.250.11

137 92 0.40138 91 0.50

0.180.230.16

DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG

119 P2133 P2104 P2125 P2128 P2122 P2149 P2106 P2127 P2137 P2132 P2141 P2

TWD 9TWD 7TWD 12TWD 14TWD 17TWD 9TWD 5TWD 14TWD 16TWD 7TWD 9TWD 6

AV7AV3AV2AV4AV7AV8AV5AV2AV2AV3AV4AV6

+0.00+0.00-0.28+0.00+0.00+0.00+0.20-0.35-0.07-0.02+0.00+0.07

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

LAR

LAR

37 COLD37 COLD37 COLD37 COLD37 COLD37 COLD37 COLD37 COLD37 COLD37 COLD37 COLD37 COLD

PROBE

61OUL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

Total Tubes : 1231Total Records: 3549

Page 76: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 1 of 40

SG 2B Indication Listings

Listing Description Page No.

Tubes Plugged Listing 2

Bobbin WEAR at AVB locations 20-1 00%TWD 3

Bobbin WEAR at Broached Supports 20-100% TWVD 3

Bobbin WEAR at Broached Supports 1-19% TWD 3

WEAR (WAR) sized by +PointTM probe 1-100% 4

SG 2B Wear Indications 1-19% TWD at AVB locations 6

Page 77: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Rev. 0Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1 SG 2B, Page 2 of 40

St. Lucie Unit 2 (SL2-1 8)SG 2B Tubes Plugged Listing

ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL# LEG PROBE

80 17 0.57 115 P2 TWD 19 AV3 +1.00 TEE TEC LOCOK 60 COLD 61OUL0.62 119 P2 TWD 20 AV4 +0.98 TEN TEC LOCOK 60 COLD 61OUL

101 84 0.16 74 P2 TED 7 AVI +0.04 TER TEC 2 COLD Sl1UL0.59 113 P2 TED 20 AV2 +0.44 TEN TEC 2 COLD 61OUL1.07 101 P2 TED 27 AV3 +0.13 TEN TEC 2 COLD 61OUL

0.52 106 P2 TWD 18 AV4 +0.37 TEN TEC 2 COLD 61OUL0.19 118 P2 TED 8 AVS +0.09 TEN TEC 2 COLD 61OUL0.39 106 P2 TED 15 AV6 -0.26 TEN TEC 2 COLD 61OUL0.48 110 P2 TWD 17 AV7' -0.07 TEE TEC 2 COLD 61OUL0.28 113 P2 TWD 12 AV8 -0.02 TEN TEC 2 COLD 61OUL

..........................................................................................................

107 86 0.33 104 P2 TWD 12 AV2 +0.07 TEN TEC 5 COLD 61OUL1.02 108 P2 TWD 25 AV4 +0.02 TEN TEC 5 COLD 610UL0.39 109 P2 TWD 13 AV5 +0.00 TEE TEC 5 COLD 61OUL

0.49 106 P2 TWD 16 AV6 +0.02 TEN TEC 5 COLD 61OUL0.60 103 P2 TWD 18 AV7 +0.04 TEE TEC 5 COLD 61OUL

..........................................................................................................

119 86 0.38 120 P2 TWD 13 AVI +0.00 TEN TEC 6 COLD 610UL0.45 116 P2 TWD 15 AV2 +0.00 TEN TEC 6 COLD 61OUL0.98 108 P2 TWD 25 AV3 +0.00 TEN TEC 6 COLD 61OUL0.58 111 P2 TWD 18 AV4 +0.00 TEN TEC 6 COLD 610UL1.21 112 P2 TWD 28 AV5 +0.00 TEE TEC 6 COLD 61OUL0.24 98 P2 TWD 9 AVG +0.00 TEN TEC 6 COLD 61OUL0.37 123 P2 TWD 13 AV7 +0.00 TEE TEC 6 COLD 61OUL0.17 81 P2 TWD 7 AV8 +0.00 TEN TEC 6 COLD 10UL

..........................................................................................................

126 85 0.39 121 P2 TWD 14 AV4 +0.04 TEN TEC 1 COLD 61OUL1.11 118 P2 TWD 27 AV5 +0.13 TEE TEC 1 COLD 61OUL0.35 129 P2 TWD 13 AV7 +0.07 TEE TEC 1 COLD 61OUL0.26 136 P2 TWD 10 AV3 -0.11 TEN TEC 1 COLD 61OUL

..........................................................................................................

134 67 0.38 103 P2 TWD 13 AV4 -0.28 TEN TEC 80 COLD 61OUL1.24 111 P2 TWD 27 AV5 +0.00 TEN TEC 80 COLD 61OUL0.27 102 P2 TWD 10 AV6 +0.00 TEN TEC 80 COLD SlOUL0.23 111 P2 TWD 9 AV7 +0.00 TEN TEC 80 COLD 61OUL0.19 114 P2 TWD 7 AV3 +0.11 TEE TEC 80 COLD SlOUL

Total Tubes : 6Total Records: 32

Page 78: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 3 of 40

St. Lucie Unit 2 SG 2B (SL2-18)Bobbin WEAR at AVB locations 20-1 00%TWD

ROW

8o9698101

104105107107109110112114115116117118119

120121122123125126127134134

COL VOLTS

17 0.6285 0.7885 0.6984 0.59

1.0785 0.6884 0.7684 0.6386 1.0284 0.7995 0.9885 0.7585 0.7186 0.6985 0.7886 0.8983 0.6986 0.98

1.2185 0.7286 0.7685 0.6384 0.5886 0.8085 1.1186 0.8467 1.2485 0.87

DEG CHN

119 P2106 P2121 P2113 P2101 P2106 P2104 P2116 P2108 P2110 P2113 P2114 P2119 P2108 P2119 P2112 P2114 P2108 P2112 P2116 P2110 P2125 P2126 P2106 P2118 P2115 P211 P2108 P2

IND %TW

TWD 20TED 23TWD 21TWD 20TED 27T•D 21TED 23TWD 20TWD 25TWD 23TED 24TWD 23TWD 21TWD 20TWD 24TED 23TWD 21TWD 25TWD 28TWD 23TWD 21TWD 20TWD 20TWD 22T•D 27T•D 23T•D 27TWD 23

LOCATION EXT EXT

AV4 +0.98 TEE TECAV3 -0.09 TEH TECAV7 +0.04 TEE TECAV2 +0.44 TEE TECAV3 +0.13 TEE TECAV3 +0.09 TEE TECAV6 +0.11 TEE TECAV6 +0.00 TEE TECAV4 +0.02 TEE TECAV5 +0.00 TEE TECAV4 +0.00 TEE TECAV2 +0.09 TEE TECAV3 +0.09 TEE TECAV6 +0.11 TEE TECAV2 +0.04 TEE TECAVS +0.22 TEE TECAVS +0.00 TEE TECAV3 +0.00 TEE TECAVS +0.00 TEE TECAV3 +0.02 TEE TECAV4 -0.07 TEE TECAV5 +0.09 TEE TECAV4 +0.02 TEE TECAV3 +0.00 TEE TECAV5 +0.13 TER TECAV5 +0.00 TEE TECAV5 +0.00 TEE TECAV3 +0.00 TEE TEC

UTIL 1 UTIL 2

LOCOK

CAL #

6021222215

21321

525166251

251

68080

LEG PROBE

COLD 610)LCOLD 610ULCOLD 61OULCOLD 610ULCOLD 610ULCOLD 61OULCOLD 61OULCOLD 610ULCOLD 61OULCOLD 610ULCOLD 61OULCOLD 610ULCOLD 61OULCOLD 61OULCOLD 610ULCOLD 61OULCOLD 610UJLCOLD 61OULCOLD 610ULCOLD 610ULCOLD 610ULCOLD 61OULCOLD 610ULCOLD 610ULCOLD 610ULCOLD 610ULCOLD 610ULCOLD 61OUL

Total Tubes : 26Total Records: 28

St. Lucie Unit 2 SG 2B (SL2-18)

Bobbin WEAR at Broached Supports 20-100% TWD

ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

Total Tubes : 0Total Records: 0

(None)

St. Lucie Unit 2 SG 2B (SL2-18)Bobbin WEAR at Broached Supports 1-19% TWD

ROW COL

42 744 7124 51

VOLTS

0.120.200.10

DEG CHN IND %TW

142 P3 TWD 7153 P3 TWD 1I144 P3 TWD 6

LOCATION EXT EXT UTIL 1 UTIL 2 CAL #

04C -0.73 TEE TEC 8204C -0.70 TEE TEC 5206C -0.75 TEE TEC 21

LEG PROBE

COLD 610ULCOLD 610ULCOLD 610UL

Total Tubes : 3Total Records: 3

Page 79: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 4 of 40

St. Lucie Unit 2 SG 2B (SL2-18)WEAR (WAR) sized by +PointTM probe 1-100% (TWD located in UTIL 1 column)(Confirmed as two sided wear & reported as DSI by Bobbin probe)

ROW COL VOLTS

95 86 0.100.510.69

DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL #

92 P5 WAR AV3 -0.02 AV3 AV3 4 96910.1 1393 PS WAR AV3 +0.02 AV3 AV3 19 96910.1 13

109 P2 DSI AV3 +0.11 TEH TEC LAR 20 5

LEG PROBE

HOT 5601PHOT 5601PCOLD 610UL

96 85 0.61 90 P5 WAR AV2 -0.10 AV2 AV2 22 96910.1 13 HOT 5601P0.06 80 P5 WAR AV2 -0.01 AV2 AV2 3 96910.1 13 HOT 5601P0.69 106 P2 DSI AV2 +0.00 TEH TEC LAR 22 2 COLD 61OUL0.16 89 P5 WAR AV7 -0.08 AV7 AV7 7 96910.1 106 COLD 5601P0.76 107 P2 DSI AV7 +0.02 TEH TEC LAR 23 2 COLD 61OUL0.51 87 PS WAR AV7 +0.05 AV7 AV7 20 96910.1 106 COLD 5601P

..........................................................................................................

97 86 0.69 117 P2 DSI AV3 +0.00 TEH TEC LAR 20 6 COLD 610UL0.33 98 P5 WAR AV3 +0.03 AV3 AV3 13 96910.1 13 HOT 5601P0.45 92 P5 WAR AV3 +0.09 AV3 AV3 17 96910.1 13 HOT 5601P

0.30 86 P5 WAR AV7 -0.04 AV7 AV7 13 96910.1 106 COLD 5601P0.67 119 P2 DSI AV7 +0.00 TEH TEC LAR 20 6 COLD 610UL

0.35 90 P5 WAR AV7 +0.03 AV7 AV7 15 96910.1 106 COLD 5601P..........................................................................................................

99 86 0.49 94 P5 WAR AV2 -0.10 AV2 AV2 19 96910.1 13 HOT 5601P0.73 112 P2 DSI AV2 -0.09 TEH TEC LAR 20 5 COLD 61OUL

0.30 92 P5 WAR AV2 -0.06 AV2 AV2 12 96910.1 13 HOT 5601P0.36 95 P5 WAR AV3 -0.10 AV3 AV3 20 96910.1 18 HOT 5601P0.23 98 P5 WAR AV3 -0.07 AV3 AV3 14 96910.1 18 HOT 5601P

0.87 118 P2 DSI AV3 +0.20 TEH TEC LAR 23 5 COLD 61OUL0.41 86 P5 WAR AV7 -0.05 AV7 AV7 17 96910.1 106 COLD 5601P0.31 88 P5 WAR AV7 +0.07 AV7 AV7 14 96910.1 106 COLD 5601P0.83 110 P2 DSI AV7 +0.11 TEH TEC LAR 22 5 COLD 61OUL

..........................................................................................................

100 83 0.64 115 P2 DSI AV5 +0.00 TEH TEC LAR 21 2 COLD 610UL0.33 92 P5 WAR AV5 +0.07 AV5 AV5 14 96910.1 106 COLD 5601P0.36 88 P5 WAR AV5 +0.27 AV5 AV5 16 96910.1 106 COLD 5601P

106 85 0.32 93 PS WAR0.44 94 PS WAR0.67 125 P2 DSI

AV7 -0.13AV7 -0.09AV7 +0.02

AV7 AV7 13AV7 AV7 17TEH TEC LAR

96910.1 13 HOT 5601P96910.1 13 HOT 5601P21 1 COLD 61OUL

108 85 0.59 90 PS WAR AV2 +0.04 AV2 AV2 22 96910.1 13 HOT 5601P

0.67 119 P2 DSI AV2 +0.07 TEH TEC LAR 22 2 COLD 61OUL0.12 94 P5 WAR AV2 +0.10 AV2 AV2 5 96910.1 13 HOT 5601P

112 83 0.24 95 P5 WAR AV40.40 90 P5 WAR AV40.82 116 P2 DSI AV40.46 86 PS WAR AVS0.27 88 PS WAR AVS0.70 118 P2 DSI AV5

120 85 0.13 91 P5 WAR AV70.70 122 P2 DSI AV70.53 84 P5 WAR AV7

--------------------------------------

121 86 0.26 87 PS WAR AV6

0.85 113 P2 DSI AV60.54 81 P5 WAR AV6

-0.03 AV4 AV4 14 96910.1 18 HOT 5601P+0.00 AV4 AV4 21 96910.1 18 HOT 5601P

+0.00 TEH TEC LAR 24 2 COLD 61OUL-0.22 AV5 AV5 19 96910.1 106 COLD 5601P-0.05 AVS AV5 12 96910.1 106 COLD 5601P+0.00 TEH TEC LAR 22 2 COLD 61OUL

-0.08 AV7 AV7 ý7 96910.1 106 COLD 5601P+0.00 TEH TEC LAR 22 2 COLD 61OUL+0.03 AV7 AV7 21 96910.1 106 COLD 5601P

....................................................................

-0.20 AV6 AV6 12 96910.1 106 COLD 5601P+0.02 TEH TEC LAR 22 5 COLD 61OUL+0.16 AV6 AV6 21 96910.1 106 COLD 5601P

Page 80: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Rev. 0Steam Generator Tube Inspection Report

Attachment 2 to Enclosure I SG 2B, Page 5 of 40

WEAR (WAR) sized by +PointTM probe 1-100% (TWD located in UTIL 1 column) (continued)

(Confirmed as two sided wear & reported as DSI by Bobbin probe)

ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

124 85 0.39 93 P5 WAR AV6 -0.13 AV6 AV6 15 96910.1 13 HOT 5601P0.31 93 P5 WAR AV6 -0.06 AV6 AV6 12 96910.1 13 HOT 5601P0.59 125 P2 DSI AV6 +0.02 TEH TEC LAR 20 2 COLD 610UL0.39 89 P5 WAR AV7 -0.15 AV7 AV7 17 96910.1 106 COLD 5601P0.35 90 PS WAR AV7 -0.01 AV7 AV7 15 96910.1 106 COLD 5601P0.72 125 P2 DSI AV7 +0.00 TEH TEC LAR 23 2 COLD 61OUL

..........................................................................................................

Total Tubes : 11Total Records: 51

Page 81: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 6 of 40

St. Lucie Unit 2 (SL2-18)SG 2B Wear Indications 1-19% TWD at AVB locations

ROW COL VOLTS DEG CHN IND %TW

37 6 0.14 92 P2 TWD 638 163 0.14 118 P2 TWD 6

0.13 59 P2 TWD 539 6 0.11 40 P2 TWD 4

0.10 31 P2 TWD 439 164 0.26 114 P2 TWD 10

0.16 114 P2 TWD 60.11 50 P2 TWD 5

40 163 0.11 117 P2 TWD 50.13 138 P2 TWD 5

41 164 0.13 119 P2 TWD 544 7 0.21 112 P2 TWD 844 163 0.21 130 P2 TWD 8

0.18 129 P2 TWD 70.21 136 P2 TWD 8

45 162 0.15 61 P2 TWD 60.13 78 P2 TWD 5

46 7 0.16 72 P2 TWD 60.14 114 P2 TWO 5

46 9 0.10 128 P2 TWD 50.10 97 P2 TWD 5

46 11 0.10 123 P2 TWD 546 161 0.12 117 P2 TWD 5

0.14 107 P2 TWD 647 8 0.15 121 P2 TWD 7

0.11 107 P2 TWO 547 10 0.19 118 P2 TWD 847 12 0.14 90 P2 TWD 647 24 0.11 95 P2 TWD 547 162 0.16 136 P2 TWD 7

0.13 100 P2 TWD 548 7 0.23 98 P2 TWD 948 9 0.23 104 P2 TWD 10

0.10 128 P2 TWD 548 11 0.14 125 P2 TWD 648 163 0.21 119 P2 TWD 849 8 0.12 122 P2 TWD 6

0.11 134 P2 TWD 549 10 0.26 108 P2 TWO 1149 12 0.14 107 P2 TWD 7

0.08 69 P2 TWD 449 24 0.16 82 P2 TWD 749 158 0.12 101 P2 TWD 5

0.14 130 P2 TWD 649 160 0.17 107 P2 TWD 749 162 0.11 135 P2 TWD 550 7 0.15 112 P2 TWD 650 9 0.11 124 P2 TWD 5

0.08 65 P2 TWD 450 11 0.11 60 P2 TWD 5

0.13 128 P2 TWD 60.10 82 P2 TWD 5

50 161 0.20 117 P2 TWD 751 8 0.16 131 P2 TWD 7

0.22 121 P2 TWD 1051 10 0.10 85 P2 TWD 5

0.11 127 P2 TWD 551 14 0.20 106 P2 TWD 951 24 0.21 121 P2 TWD 951 162 0.16 98 P2 TWD 6

0.22 120 P2 TWD 9

LOCATION

AV7 -0.22AV2 -0.18AV7 +0.28AV2 -0.15AV7 -0.09AV2 -0.18AV7 +0.31AV8 +0.29AV2 -0.24AV7 +0.31AV7 -0.27AV3 -0.19AV2 -0.24AV3 -0.22AV6 +0.29AV8 -0.20AVi +0.24AV7 +0.26AV3 -0.20AVG +0.24AV3 -0.17AV3 -0.15AV6 +0.26AV2 -0.18AV6 +0.22AV2 -0.15AV3 +0.30AV3 -0.15AV3 +0.28AV3 -0.18AVG .+0.31AV3 -0.17AV2 -0.13AV6 +0.22AV3 -0.13AV2 -0.22AV7 +0.24AV6 +0.24AV3 +0.24AV3 -0.15AV2 -0.15AV3 +0.32AV6 +0.24AV7 +0.24AV7 +0.20AV3 -0.20AV3 -0.17AV7 +0.26AVi +0.22AVl -0.18AV3 -0.17AV7 +0.24AV6 +0.29AVG +0.28AV3 -0.11AV8 -0.13AV3 -0.15AV2 -0.17AV3 +0.30AV2 -0.13AV3 -0.09

EXT EXT

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEE TECTEH TECTEH TECTEH TECTEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TEC

UTIL 1 UTIL 2 CAL #

52686852526868686969695269696968685252606060686861616061666969526161616960606160606769696868526060606060

68616160

60

61666969

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

61OLTL610UL610UL61OUL610UL610UL610UL610UL610UL610UL61OUL610UL61OUL61011L610OUL610)L.610UL610UL6100L610UL610UL610UL61OUL6100UL610UL61OLL6101UL610UL610UL6100UL610UL610T1L610UL610UL610UL6101UL610UL61001.6101TL610ULT610UL61001L610UL6100UL610UL610UL61OUL610UL610U)L6100UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL3610UL

Page 82: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 7 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

52 9 0.140.16

52 11 0.110.130.14

52 13 0.080.130.15

52 17 0.1052 23 0.2152 161 0.1853 8 0.09

0.100.080.09

53 10 0.1853 24 0.2853 158 0.18

0.130.16

53 160 0.150.110.16

53 162 0.230.13

54 9 0.100.340.170.190.130.09

54 11 0.150.120.10

54 13 0.160.13

54 15 0.0954 139 0.11

54 153 0.0954 161 0.51

0.170.14

55 10 0.110.13

55 12 0.160.140.18

55 14 0.3055 24 0.1255 146 0.1355 158 0.11

0.110.12

55 160 0.170.41

56 9 0.180.42

56 11 0.090.080.10

DEG CHN

88 - P298 P2136 P2100 P2113 P2133 P2Il P297 P2121 P2123 P2127 P299 P2126 P2100 P258 P2111 P288 P2142 P2116 P2125 P296 P2102 P2130 P2126 P2128 P285 P2118 P2121 P291 P2108 P267 P287 P273 P256 P268 P254 P2120 P261 P290 P2110 P2123 P284 P276 P2115 P2109 P2114 P284 P2124 P2105 P276 P246 P290 P2112 P211 P2119 P259 P2110 P285 P287 P292 P2

IND %TW LOCATION

TWD 7 AV2 -0.15TWD 7 AV7 +0.24TWD 5 AV7 +0.22TWD 6 AVG +0.26TWD 6 AV3 -0.19TWD 4 AV7 +0.26TWD 6 AV3 +0.28TWO 7 AV2 -0.17TWD 5 AV3 -0.20TWD 9 AV3 -0.11TWD 7 AVE +0.27TWD 4 AV7 +0.30TWD 5 AV3 -0.15TWD 4 AV2 -0.15TWD 4 AVI -0.13TWD 8 AV2 -0.20TWD 12 AV3 +0.41TWD 7 AV3 -0.16TWD 5 AVE +0.27TWD 7 AV7 +0.24TWD 6 AV7 +0.24TWD 5 AV3 -0.13TWO 6 AV2 -0.15TWD 9 AV3 -0.17TWD 5 AVE +0.26TWD 5 AV8 +0.19TWD 13 AV7 +0.26TWO 8 AV3 -0.15TWD 8 AV2 -0.15TWD 6 AVi -0.11TWD 4 AV6 -0.09TWD 7 AV7 +0.26TWD 6 AV2 -0.11TWD 5 AV8 +0.11TWD 7 AV7 +0.35TWD 6 AVi -0.11

TWD 4 AV7 +0.26TWD 5 AVE +0.26TWD 4 AV6 -0.13TWD 16 AVE +0.26TWD 7 AV3 -0.13TWD 5 AVI -0.18TWD 5 AV7 +0.26T•D 6 AVI -0.13TWO 7 AV3 -0.13TWD 7 AV2 -0.11TWD 8 AVi +0.04TWO 12 AV3 -0.22TWO 5 AV3 +0.30TWD 5 AVE +0.20TWD 5 AV7 +0.26TWD 4 AVG +0.22TWD 5 AV3 -0.15TWO 7 AV2 +0.00TWN] 14 AV7 +0.27TWD 8 AV7 +0.24TWD 16 AV3 -0.15TWD 4 AV7 +0.24TWO 4 AV6 +0.24TWO 5 AV3 -0.15

EXT EXT UTIL 1 UTIL 2

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

CAL #

616160606060606060676960606060616769696968686868686060606060606161616161604165686868606061616161666268686869696161606060

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL610UL610UL610UL610UL610ULL610UL610UL610UM610UL610UL610UL610UL610UL610UL6100LL610UL610UL610UL610UL610UL610UL610UL61001L61001L61001.610UL610UL610UL610UL610UL610UL610UL610UL61001.61001.610UL610UL61001.610UL610UL610UL610UL610UL610UL610UL61001.610UL610UL610UL610UL610UL610UL610UL6101UL610UL610UL

Page 83: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 8 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

56 13 0.130.09

56 15 0.1256 51 0.1456 139 0.1256 155 0.1056 159 0.13

0.2156 161 0.11

0.2557 10 0.16

0.250.15

57 12 0.130.13

57 16 0.090.11

57 24 0.3057 152 0.1057 154 0.14

0.1457 158 0.19

0.170.25

57 160 0.190.21

58 9 0.120.13

58 11 0.120.15

58 13 0.2158 15 0.1158 51 0.1458 143 0.1458 159 0.2158 161 0.1259 10 0.14

0.270..120.170.16

59 12 0.2159 14 0.28

0.1159 154 0.13

0.1159 156 0.1359 158 0.16

0.210.160.30

59 160 0.140.190.18

60 11 0.130.32

60 13 0.090.140.190.080.11

60 23 0.18

DEG CHN

145 P281 P2103 P2107 P2126 P2103 P2121 P2155 P283 P2131 P290 P2107 P272 P2119 P282 P2118 P2136 P2107 P270 P294 P2103 P2133 P2118 P2126 P211 P2126 P2127 P292 P281 P2129 P269 P2124 P2146 P2110 P299 P292 P2109 P2115 P2135 P2107 P295 P2107 P2112 P299 P2120 P281 P274 P2140 P290 P290 P2103 P2119 P2123 P2111 P2136 P2126 P298 P299 P298 P2129 P278 P2104 P2

IND %TW

TWO 6TWO 4TWO 6TWO 6TWDO5

TWO 4TWO 6TWO 8

TWO 5TWD 10

TWD 7TWO 11TWD 7TWO 6

TWD 6TWO 4TWO 5TWO 13TWO 4TWO 6TWO 6

TWD 7TWO 7TWO 9TWD 7TWO 8TWO 6TKW 6TWO 6TWO 7

TWO 9TWDO5TWO 6TWO 6TWD 8TWDO5TWO 7TWO 11TWO 5TWO 7TWO 7TWO 9TWO 12TWO 6TWDO5TWO 4TWO 6

TWO 6TWO 8TWD 6TWO 11

TWO 6TWO 8TWO 7TWO 6TWO 13TWO 4TWO 6TWO 8TWO 4TWO 5TWO 8

LOCATION EXT EXT

AV7 +0.24 TEH TECAV2 -0.15 TEH TECAV7 +0.15 TEH TECAV3 -0.22 TEH TECAV6 +0.20 TEH TECAV6 +0.29 TEH TECAV6 +0.24 TEH TECAV8 +0.31 TEH TECAV3 -0.11 TEH TECAV6 +0.24 TEH TECAV8 +0.26 TER TECAV7 +0.26 TEH TECAVI -0.11 TEH TECAV7 +0.24 TEH TECAVI +0.07 TEH TECAV6 +0.24 TEH TECAV3 -0.13 TEH TECAV3 +0.37 TEH TECAV6 +0.27 TEH TECAV7 +0.29 TEH TECAV6 +0.22 TEH TECAV3 -0.18 TEH TECAV6 +0.22 TEH TECAV7 +0.20 TEH TECAV2 -0.15 TEH TECAV7 +0.26 TEH TECAV6 -0.22 TEH TECAV7 +0.26 TEH TECAV7 +0.22 TEH TECAV3 -0.13 TEH TECAV7 +0.24 TEH TECAV3 -0.17 TEH TECAV3 -0.17 TEH TECAV6 +0.22 TEHiTECAVG +0.26 TEH TECAV6 +0.26 TEH TECAV8 +0.24 TEH TECAV7 +0.26 TEH TECAV3 -0.13 TEH TECAV2 -0.15 TEH TECAVI -0.16 TEH TECAV7 +0.26 TEH TECAV3 -0.13 TEH TECAV7 +0.24 TEH TECAVG +0.22 TEH TECAV7 +0.24 TEH TECAV6 +0.24 TEH TECAV2 -0.11 TEH TECAV3 +0.07 TEN TECAV6 +0.31 TEH TECAV7 +0.24 TEN TECAVI -0.09 TEH TECAV7 +0.24 TEH TECAV8 +0.22 TEH TECAV7 +0.22 TEH TECAV3 +0.30 TEH TECAV8 +0.20 TEH TECAV7 +0.22 TEH TECAV3 -0.15 TEH TECAV2 -0.13 TEH TECAVI -0.20 TEH TECAV3 -0.15 TEH TEC

UTIL 1 UTIL 2 CAL #

606061444265696969696161616060606067656565696969686860606161616O435868686060606060616161646473686868686969696060

606060606067

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610OL61013L610UL610UL610LL610UL610TUL610!L610UL61OUL610JL

61OUL610U1L610UL61OUL61013L610UL610T3L61OUL61011L61OTL610UL610UL610UL610UL61001L610UL610UL6100.L610UL610UL610UL61001.61001.L610UL610UL610UL6101L.61001L610UL61011L61011L6100L.610UL610UL61011L610UL610M61001L6100L6101.61001L6101L.6100L.61001.610UL6100L.610UL610UL610UL610UL

Page 84: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 9 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

60 51 0.1360 153 0.1460 157 0.19

0.120.12

60 159 0.180.440.310.220.120.14

61 10 0.220.220.13

61 12 .0.150.230.13

61 14 0.180.34

61 16 0.120.16

61 158 0.120.350.20

61 160 0.130.16

62 11 0.180.130.270.12

62 13 0.190.280.18

62 15 0.0862 17 0.1862 139 0.1262 157 0.13

0.1562 159 0.1763 12 0.16

0.1263 14 0.2063 16 0.1263 156 0.24

0.1563 158 0.28

0.220.130.19

64 11 0.2264 13 0.21

0.0964 15 0.1364 23 0.1964 27 0.1364 153 0.1564 157 0.1765 12 0.13

0.110.160.080.13

65 14 0.1465 64 0.1665 104 0.14

DEG CHN

115 P288 P2115 P2109 P292 P2124 P2121 P2118 P2127 P2122 P2116 P2116 P2119 P2124 P2131 P2113 P286 P211 P2117 P2107 P2113 P2100 P2125 P2125 P2134 P297 P2111 P298 P2110 P273 P2101 P2113 P294 P2103 P290 P2117 P290 P292 P290 P2115 P267 P2122 P2130 P2125 P2100 P2109 P2128 P2123 P2101 P2120 P2122 P258 P2102 P2114 P2108 P251 P2103 P298 P259 P2118 P269 P281 P2104 P2123 P2115 P2

IND %TW LOCATION

TWD 6 AV3 -0.20TWD 6 AV6 -0.18TWD B AV7 +0.27TWD 5 AV3 +0.24TWD 5 AV8 +0.24TWD 7 AVI +0.20TWD 15 AV2 +0.13TWD 11 AV3 +0.04TWD 9 AV6 +0.00TWD 5 AV7 +0.20TWD 6 AV8 +0.27TWD 9 AV7 +0.26TWD 9 AV3 -0.13TWD 6 AV2 -0.15TWD 7 AV7 +0.22TWD 10 AV3 +0.28TWD 6 AVI -0.15TWD 8 AV7 +0.26TWD 13 AV3 -0.11TWD 5 AV6 +0.19TWD 7 AV3 +0.26TWD 5 AV2 -0.16TWN) 13 AV3 +0.31TWD 8 AV6 +0.00TWD 5 AV7 +0.22TWD 6 AV3 -0.15TWD 8 AV7 +0.26TWD 6 AV6 -0.22TWD 11 AV3 +0.31

.TWD 6 AVI -0.13TWDN 8 AV7 +0.26TWD 12 AV3 -0.17TWD 8 AV2 -0.17TWD 4 AV3 -0.13TWD 8 AV3 +0.00TWD 5 AV6 +0.26TWD 5 AVI -0.16TWD 5 AV8 +0.00TWD 7 AV3 +0.35TWD 7 AVI +0.00TWD 6 AV7 +0.20TWD 9 AV3 -0.07TWD 6 AV3 -0.11

TWD 9 AV3 +0.27TWD 6 AV7 +0.33TWD 10 AV7 +0.24TWD 8 AV6 +0.20TWD 5 AV3 -0.15TWD 7 AV2 -0.15TWD 9 AV3 -0.13TWD 9 AV7 +0.26TN) 4 AVI -0.15TW)) 6 AV2 +0.04TN) 9 AV3 -0.11TWO 6 AV3 -0.17TWD 6 AV7 +0.24TWI) 7 AV7 +0.24TWN) 6 AV8 +0.26TWD 5 AV6 -0.20TWD 7 AV3 +0.31TWD 4 AV2 +0.24TWD 6 AVI -0.15TWD 7 AV3 -0.17TWD 7 AV3 +0.20TWD 7 AV6 +0.00

EXT EXT UTIL 1 UTIL 2

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

CAL #

4464737373696969696969606060606060606060606969696868616161616161616061417272686161616173736868686860606061676764736060606060601120

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610u610UL61OUL610UL6100L61oUL610UL61oUL610UL61EUL610Lt610UL61oUL610UL610UL610UL610LT610UL610UL610UL61OUL610UL610ULL610UL61oUL610UL610UL61OUL61oUL61oUL61OUL6ioUL61OUL610UL61OUL61oUL610Lt61ULt61oUL61oUL610UL61OUL61OUL610UL61 oUL610UL610UL6lOUL61SUL610UL610UL610UL61oUL610UL610UL610UL610UL610UL61oUL61oUL610UL610UL61oUL610UL

Page 85: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 10 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

65 158 0.220.280.300.16

66 13 0.220.260.33

66 23 0.2166 155 0.1766 157 0.1967 12 0.18

0.390.12

67 18 0.1167 22 0.0967 102 0.1367 156 0.15

0.250.150.21

67 158 0.110.190.16

68 13 0.090.060.310.270.170.09

68 15 0.150.15

68 17 0.090.14

68 51 0.1468 65 0.1768 97 0.1168 109 0.13

0.1368 157 0.22

0.1969 14 0.1469 104 0.2069 152 0.1169 156 0.28

0.240.150.16

70 15 0.090.070.100.240.100.09

70 17 0.3770 19 0.0970 21 0.0970 47 0.1770 99 0.1571 14 0.19

0.140.12

71 16 0.18

DEG CHN

131 P2120 P2129 P2137 P2105 P2102 P2100 P2109 P286 P272 P2119 P2119 P298 P2117 P293 P2131 P281 P2122 P2121 P286 P297 P2137 P293 P296 P2113 P2137 P2117 P285 P2138 P297 P2101 P299 P2115 P281 P271 P2133 P2138 P2136 P2127 P299 P2117 P2128 P262 P2107 P2107 P297 P293 P263 P2131 P2116 P2110 P2123 P293 P299 P262 P258 P2139 P2331 P2120 P277 P288 P290 P2

IND %TW

TWD 9TWD 11TWD 11TWD 6TWD 10TWD 11TWD 13TWD 9TWO 7TWD 7TWD 8TWD 15TWD 6TWD 5TWD 4

TWD 5TWD 6TWD 10TWD 6TWD BTWD 4TWD 7TWD 6

TWD 4TWD 3TWD 12TWD 11TWD 8

TWD 4TWO 7TWD 7TWD 4

TWD 7TWD 6TWD 8TWD 5TWD 6TWD 6TWD 9

TWD 8TWD 7TWD 9TwD5

TED 9TWD 8TWD 5TWD 6TWO 4TWD 3TWD 5TWD 10TWD 5TWO 4TWD 14TWO 4

TWO 4

TWD 7TWD 6TWD 9TWD 7

TWD 6TWD B

LOCATION EXT EXT

AV2 -0.18 TEH TECAV3 +0.27 TEH TECAV7 +0.24 TEH TECAV8 +0.20 TEH TECAV7 +0.28 TEH TECAV3 +0.22 TEH TECAV2 +0.20 TEH TECAV3 -0.17 TEH TECAVli +0.24 TEH TECAV7 -0.15 TEH TECAV6 +0.i3 TEH TECAV3 -0.09 TEH TECAV7 +0.18 TEH TECAV7 -0.13 TEH TECAV3 -0.17 TEH TECAV3 +0.00 TEH TECAVI -0.14 TEH TECAV3 +0.29 TEH TECAV6 -0.18 TEN TECAV7 -0.18 TEH TECAV8 +0.20 TEH TECAV7 +0.22 TEH TECAV3 +0.31 TEH TECAV8 +0.24 TEH TECAV7 +0.22 TEH TECAV6 -0.02 TEH TECAV3 +0.31 TEH TECAV2 +0.26 TEH TECAV1 -0.11 TEH TECAV7 -0.11 TEH TECAV2 +0.24 TEH TECAV7 +0.20 TEH TECAV3 +0.30 TEH TECAV3 -0.13 TEH TECAV3 -0.02 TEH TECAV6 -0.02 TEH TECAV3 +0.04 TEH TECAV6 +0.02 TEH TECAV3 +0.29 TEH TECAV7 +0.22 TEH TECAV3 +0.24 TEH TECAV6 +0.00 TEH TECAVI +0.33 TEH TECAV3 +0.24 TEH TECAV6 +0.00 TEH TECAV7 -0.15 TEH TECAV8 +0.24 TEH TECAV8 +0.26 TEH TECAV7 -0.17 TEH TECAV6 -0.17 TEH TECAV3 +0.30 TEH TECAV2 +0.26 TEH TECAVl -0.13 TEH TECAV3 +0.28 TEH TECAV8 -0.13 TEN TECAV3 +0.30 TEH TECAV3 +0.17 TEH TECAV3 +0.00 TEH TECAV3 +0.28 TEH TECAV2 +0.28 TEH TECAV7 -0.15 TEH TECAV3 +0.26 TEN TEC

UTIL I UTIL 2 CAL #

696969696161616664726161616060187373737368686860

6060606060616160604412142424737360206572727272606060606060616060391761616161

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610ULT61001.610UL610UL610ML610UL0610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001.610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61DUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001.61001.6101UL610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL610UL

Page 86: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 11 of 40

SG 26 Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

71 18 0.2571 20 0.0971 154 0.17

0.140.12

72 15 0.1672 17 0.12

0.160.08

72 75 0.1472 99 0.1473 14 0.1473 16 0.2373 76 0.1673 150 0.0974 15 0.11

0.110.080.09

74 65 0.1074 67 0.11

0.1374 75 0.1474 85 0.2074 95 0.1774 97 0.15

0.160.13

74 99 0.1674 101 0.17

0.1974 151 0.1275 18 0.09

0.130.12

75 66 0.1775 86 0.1975 94 0.1475 100 0.1375 152 0.21

0.1276 17 0.10

0.1776 21 0.1576 69 0.21

0.1276 73 0.2176 77 0.2076 91 0.1476 99 0.14

0.130.150.130.11

76 153 0.1777 16 0.1177 18 0.08

0.090.09

77 20 0.160.12

77 68 0.14

104 P2 TWD 10 AV361 P2 TWD 4108 P2 TWD 7108 P2 TWD 652 P2 TWD S70 P2 TW-D 7122 P2 TWD 6119 P2 TWD 752 P2 TWD 4129 P2 TWD 7131 P2 TWD 611 P2 TWD 7136 P2 TWD 10140 P2 TWD 781 P2 TWD 4119 P2 TWD S92 P2 TWD 5119 P2 TWD 461 P2 TWD 490 P2 TWD 5106 P2 TWD 592 P2 TWD 5135 P2 TWD 6142 P2 TWD 8129 P2 TWD 781 P2 TWD 6104 P2 TWD 6122 P2 TWD 5115 P2 TWD 7110 P2 TWD 7122 P2 TWD 866 P2 TWD 5132 P2 TWD 488 P2 TWD 669 P2 TWD 5136 P2 TWD 781 P2 TWD 7140 P2 TWD 6127 P2 TWD 694 P2 TWD 898 P2 TWD 588 P2 TWD 5120 P2 TWD 794 P2 TWD 778 P2 TWD 10

76 P2 TWD 6121 P2 TWD 10118 P2 TWD 9138 P2 TWD 6144 P2 TWD 6143 P2 TWD 5128 P2 TWD 6128 P2 TWD 5111 P2 TWD 574 P2 TWD 7106 P2 TWD 534 P2 TWD 478 P2 TWD 445 P2 TWD 472 P2 TWD 743 P2 TWD 6108 P2 TED 6

AV2AV3AV7AV8AVGAVGAV3AVIAV3AV3AV2AV6AV3AVGAV8AV3AV2AVIAV2AVGAV2AV2AV3AV2AV2AV3AV4AV5AV2AV3AVGAV5AV4AV3AV3AV7AVGAV5AV4AV5AV8AV3AV5AV4AV5AV3AVSAV3AV3AV4AVSAVG

AV8AV4AV8AV7AVSAVIAV5AV8AV7

+0.33+0.20+0.11

-0.13+0.09-0.28-0.15+0.26-0.15+0.00+0.00-0.48-0.02+0.09-0.07+0.22+0.28+0.24-0.40-0.15+0.22+0.18-0.04+0.07+0.00+0.00+0.00+0.24+0.00-0.02+0.02+0.02-0.17+0.30+0.30+0.02+0.22+0.07+0.00+0.22-0.11+0.20+0.22-0.15+0.04-0.07+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.00+0.18+0.22-0.13-0.13+0.20-0.15-0.13+0.07

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

60 COLD 610ULCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

610LTL610UL610UL610UL610UL610UL610ULT61 0UL610UL610UL

61OUL610UL61001L610UL610UL610UL610UL610UL610UL610UJL610UL6 10UL610UL610UL610UL610UL610UL610ULG10UL610UL610UL610UL610ULL610UL610UL610UL610UL610ULG10UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610ULL610UL6 10UL610ULG6I0UL610UL610UL610UL3

10104481818181818646060606061619

Page 87: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure I

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 12 of 40

SG 28 Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

77 76 0.1977 88 0.0977 92 0.1077 94 0.1577 104 0.13

0.1177 152 0.14

0.1278 19 0.1378 51 0.10

78 69 0.1178 75 0.20

0.1678 83 0.1878 85 0.1678 95 0.23

0.1778 97 0.1978 99 0.25

0.260.32

78 101 0.150.17

78 105 0.1578 109 0.1678 151 0.1279 20 0.12

0.1279 22 0.1379 56 0.1779 86 0.19

0.250.18

79 94 0.140.100.130.11

79 96 0.220.16

79 98 0.1579 100 0.1479 104 0.1180 17 0.5780 23 0.1280 73 0.1880 77 0.20

0.1780 83 0.1780 85 0.18

0.210.14

80 87 0.160.15

80 91 0.1480 95 0.1880 99 0.11

0.1680 101 0.1480 105 0.18

0.1081 18 0.1481 70 0.11

DEG

11584ill8161106889279113i11321411381241179211811997118108144i1

142120941011121319899100145116155117117104ill1341121159075110881221171261351141241461161291191291397728125

CHN

P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2

IND %TW

TWD 8TWD 4TWD 4TWD 6TED 6

TWD 5TED 6T 5D STED 6TED 5TED 5TED 9TED 7

TED 8TED 7TED *9TED 7TED 7TED 10TED 10TED 12TWD 7TWn 7TWD 6TWD 6

TED 5TWD 6TWD 5TED 6TED 7TED 7TED 9TED 7TED 6TED 5TED 6TED 5

TED 9TED 7

TED 6TED 6TWD 5TED 19TWD 6TWD 9TWD 9TWD 8TwD 8TWD 8

TED 10TWD 7TWD 6TWD 6TWD 6TWD 7TWD 5TED 7TED 6

TED 8TED 5TED 7T 5D 5

LOCATION

AV5 -0.11AV2 -0.13AV7 -0.13AVG +0.22AV5 -0.13AV4 -0.15AV4 +0.31AV7 -0.13AV4 +0.26AV3 -0.17AV3 +0.20AV2 -0.09AV3 -0.13AV5 +0.09AV3 +0.02AV4 +0.00AVS +0.00AV2 +0.00AV4 -0.02AVG +0.04AVE -0.07AVE +0.02AVG +0.29AV4 +0.15AV5 +0.00AVG -0.02AVE -0.15AVi +0.20AV4 +0.17AV2 +0.00AV3 +0.09AV4 +0.11AV7 +0.00AV2 +0.09AV3 +0.02AV4 +0.04AVG +0.07AV2 -0.04AVE +0.07AVG +0.09AV5 +0.00AV4 -0.18AV3 +1.00AV4 +0.24AV4 +0.00AV3 +0.04AV4 +0.00AV4 +0.00AV3 +0.02AV4 +0.04AV7 +0.04AV2 +0.00AVS +0.00AV3 -0.04AV5 +0.09AV4 +0.00AVG +0.00AV4 +0.00AV4 +0.00AV5 +0.00AVG +0.50AV5 +0.13

EXT EXT

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

UTIL 1 UTIL 2 CAL #

37772020656560229331113131317171717171923646060661655588881414141819

LOCOK 606744422226681418181820

20619

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL

610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6101UL610ULT610UL610UL610UL610UL061001.

610UL6101UL6101UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001.

610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001.610UL610UL610UL6100LT610UL610UL610UL610UL610UL610UL610UL610UL

Page 88: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 13 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG

81 72 0.1581 74 0.1681 76 0.14

0.2081 80 0.21

0.2081 82 0.20

0.1481 84 0.20

0.200.19

81 86 0.220.18

81 88 0.080.13

81 92 0.140.12

81 94 0.1181 96 0.15

0.180.15

81 98 0.210.20

82 69 0.1282 73 0.1582 75 0.15

0.1482 85 0.2082 87 0.24

0.170.21

82 89 0.1182 95 0.19

0.2382 97 0.26

0.230.180.150.18

82 99 0.2182 109 0.16

0.1283 28 0.1383 58 0.1583 76 0.2383 80 0.2483 86 0.24

0.2183 88 0.2283 94 0.2383 98 0.12

0.120.15

83 100 0.1284 23 0.1984 75 0.18

0.1884 77 0.1784 81 0.1584 83 0.3384 85 0.29

0.17

90 P2 TWD 7141 P2 TWN) 7137 P2 TWD 6121 P2 TWD 986 P2 TWD 9109 P2 TWD 9122 P2 TWD 9126 P2 TWD 7117 P2 TWD 9125 P2 TWD 9102 P2 TWD 9120 P2 TWD 8125 P2 TWD 781 P2 TWD 4137 P2 TWD 5138 P2 TWD 6118 P2 TWD 5116 P2 TWD 5128 P2 TWD 6125 P2 TWD 7107 P2 TWD 6116 P2 TWD 887 P2 TWD 881 P2 TWD 5148 P2 TWD 7133 P2 TWD 7122 P2 TWD 6125 P2 TWD 8112 P2 TWD 959 P2 TWD 794 P2 TWD 865 P2 TWD 5131 P2 TWD 8123 P2 TWD 996 P2 TWD.10107 P2 TWD 9110 P2 TED 785 P2 TWD 6104 P2 TWD 7112 P2 TWD 8119 P2 TWD 6143 P2 TWD 5103 P2 TWD 6110 P2 TWD 7III P2 TWD 10128 P2 TWD 1097 P2 TWD 990 P2 TWD 8131 P2 TWD 9132 P2 TWD 9116 P2 TWD 586 P2 TWD 5113 P2 TWD 6138 P2 TWD 5101 P2 TWD 9113 P2 TWD 888 P2 TWD 9127 P2 TWD 899 P2 TED 792 P2 TWD 13135 P2 TWD 12123 P2 TWD 8

AV5AV2AV4AV5AV4AVS

AV3AVSAV3AV4AVSAV4AVS

AV2AV5AV2AV4AV4AV6AV7AV4AV4AV5AV4AV2AV5AVEAV3AV4AVEAV6AV4AV2AV3AV2AV3AV4AV5AV7AV2AV4AV3AVS

AV4AV5AVSAV4AV7AV3AV4AV2AV4AVEAV5AV3AV4AV5AVE

AV5AV3AV4AV5

+0.00+0.02-0.11-0.07+0.00+0.00+0.00+0.02+0.09-0.13+0.04+0.00+0.00-0.07+0.18+0.00-0.11-0.18+0.00+0.00+0.00+0.00+0.00-0.18-0.07+0.07+0.09+0.07+0.07

+0.07+0.09-0.13+0.00+0.00+0.00

+0.00+0.00+0.00+0.00+0.00+0.09+0.00+0.17+0.00+0.00+0.00+0.00-0.04-0.07+0.02

-0.02+0.04+0.11+0.00+0.02+0.00

+0.00

+0.00+0.00

-0.11

+0.09+0.09

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

4333222222266

777771313131313

93331555713131313131313172323661541558814141418674442222

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL610UL6100UL610UL610UL61001.6101UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61OUL

010UL.61OUL61EUL610UL610UL610UL610UL610UL610UL61001.61L0610UL610UL610UL610UL610UL6100L.610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL61001.610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

Page 89: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 14 of 40

SG 28 Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

84 87 0.200.21

84 89 0.1884 95 0.17

0.310.27

84 97 0.2084 99 0.12

0.1584 101 0.16

0.1285 70 0.13

0.2285 86 0.12

0.180.13

85 92 0.280.120.10

85 96 0.200.15

85 98 0.1986 23 0.1386 71 0.1386 73 0.2386 81 0.1686 85 0.31

0.260.28

86 87 0.270.270.230.400.260.20

86 89 0.160.170.12

86 95 0.210.180.18

86 97 0.150.32

86 99 0.230.160.17

87 70 0.1487 72 0.18

0.1687 74 0.19

0.1687 76 0.1887 78 0.2087 s0 0.1787 82 0.16

0.2087 84 0.16

0.350.280.17

DEG

118ill

14412212412913310814013313314210811612810412113310012086108127127123114112120115101951061039260129921121301001271301131051359662122134100

94141121135133124113122127125

CHN

P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2

IND %TW LOCATION EXT EXT UTIL 1 UTIL 2

TDB8 AV4 +0.00 TERTECTWD 8 AV6 +0.00 TEE TECTWD 8 AV6 +0.00 TEE TECTWD 7 AV6 +0.04 TEH TECTWD 12 AV2 +0.00 TEE TECTWD 10 AV3 +0.04 TEH TECTWD 8 AV2 +0.04 TEE TECTWD 5 AV5 +0.00 TEE TECTWD 6 AVG +0.00 TEE TECTWD 7 AV2 +0.00 TEH TECTWD 5 AV2 +0.00 TEH TECTWD 5 AVG +0.22 TEE TECTWD 9 AV5 +0.00 TEE TECTWD 5 AV4 +0.00 TEE TECTWD 7 AV4 +0.00 TEE TECTWD 6 AVG +0.00 TEE TECTWD 10 AV2 +0.04 TEE TECTWD 5 AV3 -0.13 TEE TECTWD 4 AV4 -0.13 TEE TECTWD 8 AV2 +0.00 TEE TECTWD 6 AV4 +0.00 TEE TECTWD 7 AV2 +0.00 TEE TECTWD 6 AVS +0.00 TEE TECTWD 6 AV3 +0.00 TEE TECTWD 10 AV4 +0.02 TEE TECTWD 7 AVS +0.33 TEE TECTWD 12 AV2 +0.04 TEE TECTWD 10 AV3 +0.07 TEE TECTWD 11 AV4 +0.09 TEE TECTWD 10 AV3 +0.00 TEE TECTWD 10 AV4 +0.00 TEE TECTWD 9 AVS +0.00 TEE TECTWD 13 AVG +0.00 TEE TECTWD 9 AV7 +0.00 TEH TECTWD 8 AV8 +0.00 TEE TECTWD 6 AV4 -0.13 TEE TECTED 7 AVG +0.27 TEE TECTWD 5 AV7 +0.22 TEE TECTWD 8 AV3 +0.00 TEE TECTWD 7 AVS +0.00 TEE TECTWD 7 AV7 +0.00 TEE TECTWD 6 AV7 +0.00 TEE TECTWD 11 AV2 +0.00 TEE TECTWD 9 AVG +0.02 TEE TECTWD 7 AV3 +0.02 TEE TECTWD 7 AVI +0.02 TEE TECTWD 7 AV2 +0.04 TEE TECTWD 8 AV2 +0.07 TEE TECTWD 7 AV4 -0.04 TEE TECTWDS7 AV4 +0.00 TEH TECTWD 8 AVS +0.00 TEE TECTWD 8 AVS +0.13 TEE TECTWD 9 AV4 +0.02 TEE TECTWD 7 AV5 +0.02 TEE TECTWD 7 AV4 +0.11 TEE TECTWD 8 AV7 +0.02 TEE TECTWD 7 AV3 +0.09 TEE TECTWD 13 AV4 +0.11 TEE TECTWD 11 AVS +0.18 TEE TECTWD 7 AV6 +0.07 TEE TEC

CAL #

6681414141418181818996667771313136693111155555

7771313131313171717103344421111111

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

6 lOUL610UL.

610UL610UL610ULG10UL610UL610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6 10UL610ULT610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6 10UL610UL

61001.

Page 90: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 26, Page 15 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

87 86 0.300.140.420.180.16

87 88 0.170.150.20

87 90 0.1287 92 0.1387 94 0.1387 96 0.12

0.300.350.19

87 98 0.1787 100 0.18

0.130.12

88 29 0.1188 71 0.1188 73 0.3088 75 0.1888 79 0.1288 81 0.1388 85 0.41

0.230.230.200.16

88 87 0.200.17

88 89 0.1788 95 0.15

0.120.160.190.20

88 97 0.240.340.130.110.13

88 99 0.140.120.130.13

88 105 0.1589 68 0.15

0.1789 72 0.16

0.1689 74 0.2189 76 0.2089 80 0.17

0.240.20

89 82 0.340.19

DEG CHN

86 P2104 P2115 P276 P293 P2141 P2126 P2138 P2119 P2108 P2102 P2116 P2105 P2107 P211 P292 P2114 P2127 P2138 P2121 P254 P211 P2107 P2111 P2109 P2116 P2123 P2

.117 P2144 P2129 P2125 P2105 P2136 P290 P2130 P2100 P2115 P289 P2124 P2113 P2122 P2111 P2125 P2135 P2139 P211 P2137 P2131 P2127 P2133 P267 P2113 P2137 P2140 P290 P279 P293 P2120 P2126 P2

IND %TW

TH 11TWH 6THU 14TWU 7TWH 6TrD 7TWH 6TWU 8TwHU5TWH 6TWH 6T 5D 5THU 11

THU 13TWH 8TWD 7TWH 7

TWH 6TWH 5TWH 5TWH 6THU 13TWD 9TWD 6TWD 6THU 16THU 10THU 10TWH 9

TWH 7TWD 8TWH 7TWH 7TWH 6TWH 5TWU 7TWH 8TWH 8THU 10THU 13TWH 6TWH 5TWD 6TWD 6

TWH 5TWH 6TWH 5TWD 7TWH 6TWH 7TWU 8TWH 8TWH 9TKH 9TWH 8

THD 10TWH 9THU 14TWO 9

LOCATION EXT EXT

AV3 +0.04 TEH TECAV4 -0.07 TEN TECAV5 -0.02 TEN TECAVG -0.02 TEN TECAV7 -0.16 TEH TECAV3 -0.09 TEH TECAV4 -0.16 TEN TECAV5 +0.11 TEN TECAV5 +0.22 TEN TECAV4 -0.04 TEN TECAV4 +0.07 TEE TECAVI +0.04 TEN TECAV2 +0.09 TEN TECAV3 -0.04 TEN TECAV4 +0.02 TEE TECAV8 -0.02 TEN TECAV4 +0.00 TEN TECAVG +0.00 TEN TECAV7 +0.00 TEN TECAVI +0.24 TEN TECAVG +0.17 TEN TECAV4 +0.00 TEN TECAV2 +0.00 TEN TECAV4 +0.07 TEN TECAVG +0.07 TEN TECAV2 +0.11 TEN TECAV3 -0.02 TEN TECAV4 +0.07 TEN TECAVS +0.11 TEE TECAV7 +0.04 TEN TECAVG +0.00 TEN TECAV7 +0.00 TEN TECAV3 +0.09 TEE TECAV3 +0.02 TEN TECAV4 -0.02 TEN TECAVG +0.07 TEN TECAV7 +0.09 TEN TECAV8 +0.00 TEE TECAV2 +0.02 TEN TECAV3 +0.04 TEN TECAV4 +0.09 TEN TECAV5 +0.09 TEN TECAVG +0.02 TEN TECAVI +0.00 TEN TECAV2 +0.00 TEN TECAVG +0.00 TEN TECAV7 +0.00 TEN TECAV2 +0.00 TEN TECAV4 +0.00 TEN TECAV3 +0.00 TEN TECAVI +0.00 TEN TECAV2 +0.00 TEN TECAV2 +0.00 TEN TECAV5 +0.22 TEN TECAV2 +0.00 TEN TECAV3 +0.00 TEE TECAV5 +0.00 TEN TECAV3 +0.07 TEN TECAVG +0.00 TEN TEC

UTIL 1 UTIL 2

LAR

CAL # LEG

5 COLD5 COLD5 COLD5 COLD5 COLD8 COLD8 COLD8 COLD7 COLD8 COLD14 COLD14 COLD14 COLD14 COLD14 COLD14 COLD18 COLD18 COLD18 COLD66 COLD10 COLD4 COLD4 COLD2 COLD2 COLD2 COLD2 COLD2 COLD2 COLD2 COLD6 COLD6 COLD8 COLD14 COLD14 COLD14 COLD14 COLD14 COLD14 COLD14 COLD14 COLD14 COLD14 COLD18 COLD18 COLD18 COLD18 COLD20 COLD9 COLD9 COLD4 COLD4 COLD3 COLD3 COLD2 COLD2 COLD2 COLD2 COLD2 COLD

PROBE

610UL610UL610UL610UL610UL6101UL610UL610UL610UL610UL61001610UL610UL610UL610UL610UL610UL610UL610UL61001.6100L610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

Page 91: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure I

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 16 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

89 84 0.230.140.270.290.26

89 B6 0.160.170.140.220.17

89 88 0.180.220.260.18

89 90 0.170.210.160.190.18

89 92 0.110.18

89 94 0.170.180.140.12

89 96 0.170.270.200.180.190.13

89 98 0.400.170.140.19

90 59 0.2290 69 0.1590 73 0.16

0.1890 77 0.2090 83 0.2090 85 0.34

0.200.270.38

90 87 0.260.280.310.210.29

90 89 0.190.190.19

90 91 0.2390 93 0.24

0.1190 95 0.19

0.160.150.230.21

DEG CHN

93 P296 P2131 P2128 P2125 P2104 P2111 P2106 P278 P2136 P2136 P2130 P2117 P2113 P2123 P2106 P282 P2105 P297 P2119 P2130 P260 P286 P290 P274 P2101 P2108 P2126 P2129 P2101 P2113 P2128 P2107 P2120 P2121 P2134 P2102 P2124 P2108 P2121 P2136 P2131 P2144 P2136 P2122 P271 P289 P275 P281 P2104 P289 P279 P2105 P2118 P2,127 P2151 P2121 P285 P293 P2114 P2119 P2

IND %TW LOCATION

TWD 10 AV2 +6.00TWD 7 AV3 +0.04TWD 12 AV4 +0.02TWD 12 AVS +0.04TWD 11 AVE +0.04TWO 7 AV2 +0.00TWD 7 AV3 +0.00TWD 6 AV4 +0.00TWD 9 AV5 +0.00TWD 7 AV7 +0.00TWD 7 AV5 +0.00TWD 8 AVE +0.00TWD 10 AV7 +0.00TWD 7 AV8 +0.00TWD 7 AVG +0.13TWD 8 AV5 +0.18TWD 6 AV4 +0.04TWD 7 AV3 +0.13TWD 7 AV2 +0.15TW]) 5 AV3 -0.11TWD 7 AV5 +0.16TWD 7 AV2 +0.02TWD 7 AV3 +0.11TWD 6 AV4 +0.07TWD 5 AVS +0.09TWD 7 AVI -0.13TWD 10 AV2 +0.00TWD 8 AV3 +0.00TWD 7 AV4 +0.00TWD 8 AV5 +0.00TWD 6 AV7 +0.11TWD 14 AV2 +0.00TWD 7 AV4 +0.00TWD 6 AVE +0.04TWD 8 AVI +0.09TWD 9 AV3 +0.00TWD 6 AV5 -0.13TND 7 AV4 -0.07TWD 8 AV5 -0.02TWD 9 AV6 +0.15TWD 8 AV5 +0.00TW]) 13 AV2 +0.04TWD 8 AV4 -0.04TWD 11 AV6 +0.02TWD 14 AV7 +0.07TND 10 AV3 +0.04TWD 10 AV4 +0,09TWD 11 AV5 +0.00TWD 8 AVE +0.00TWD 11 AV7 +0.00TWD 7 AV3 +0.09TWD 7 AV4 +0.00TWD 8 AVE +0.00TWD 9 AV2 +0.00TWD 9 AV2 +0.00TWD 5 AV3 -0.13TWD 7 AV3 +0.00TWD 6 AV4 +0.00TWD 6 AV2 +0.00TWD 9 AVE +0.00TWD 8 AV5 +0.02

EXT EXT UTIL 1 UTIL 2

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEK TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

CAL #

22222666667777808080808077131313131313131313131717171716933311111

5555

777777

1313131313

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

61aOUL61OUL610UL610UL610UL610UL610014610UL

61OUL61 OUL610UL

610UL610UL610UL610UL610UL610UL610ULT610UL610UL610UL610UL610UL610TUL610UL610UL610UL610ULT610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610ULT610UL610UL610UL61OUL610UL610ULT610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

610oUt

Page 92: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 17 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

90 97 0.360.310.220.21

91 76 0.210.21

91 78 0.1291 82 0.1691 84 0.22

0.400.270.15

91 86 0.390.500.260.310.220.20

91 88 0.160.160.190.15

91 90 0.160.220.110.19

91 92 0.140.100.170.18'0.160.26

91 94 0.150.14

91 96 0.150.140.15

91 98 0.230.120.170.18

91 100 0.1392 73 0.1s92 75 0.1692 77 0.17

0.2592 79. 0.1292 81 0.27

0.240.14

92 83 0.130.38

92 85 0.240.150.250.360.43

92 87 0.190.280.180.210.250.22

DEG CHN

105 P2117 P2112 P2110 P2116 P2112 P2113 P2115 P2138 P2130 P2113 P2139 P294 P2106 P2112 P2104 P2111 P247 P2145 P2148 P2143 P2130 P283 P2126 P297 P2115 P2149 P2105 P2135 P2140 P2110 P2130 P2113 P2104 P2120 P2134 P2104 P2126 P2133 P2123 P2126 P2100 P2129 P262 P292 P2120 P2131 P2113 P2108 P245 P2108 P2112 P2108 P2116 P2125 P2117 P2117 P2117 P2112 P2123 P2106 P2129 P2123 P2

IND %TW LOCATION EXT EXT UTIL 1 UTIL 2

TWD 13 AV2 +0.00 TEH TECTWD 11 AV3 +0.00 TEH TECTWD 9 AVG +0.00 TEH TECTWD 8 AV8 +0.00 TEH TECTWD 10 AVS +0.00 TEH TECTWD 10 AV7 +0.00 TEH TECTWD 6 AVS +0.00 TEH TECTWD 7 AV5 -0.04 TEH TECTWD 9 AV3 +0.00 TEH TECTWD 15 AV4 +0.07 TEH TECTWD 11 AVS +0.07 TEH TECTWD 7 AV6 +0.09 TEH TECTWD 13 AV2 +0.13 TEH TECTWD 16 AV3 +0.00 TEH TECTWD 9 AV4 +0.09 TEH TECTWD 11 AV5 +0.09 TEH TECTWD 8 AV6 +0.00 TEH TECTWD 8 AV7 +0.22 TEH TECTWD 7 AV5 +0.02 TEH TECTWD 7 AVG +0.16 TEH TECTWD 8 AV7 -0.04 TEH TECTWD 7 AV8 +0.20 TEH TECTWD 6 AV3 -0.09 TEH TECTWD 8 AV5 +0.04 TEH TECTWD 5 AV6 +0.24 TEH TECTWD 7 AV7 +0.29 TEH TECTWD 6 AV3 +0.04 TEH TECTWD 5 AV4 +0.02 TEH TECTWD 7 AVS +0.00 TEH TECTWD 8 AV6 +0.15 TEH TECTWD 7 AV7 +0.04 TEH TECTWD 10 AV8 +0.04 TEH TECTWD 6 AV2 +0.02 TEH TECTWD 6 AV3 +0.00 TEH TECTWD 6 AVi +0.07 TEH TECTWD 6 AV2 +0.04 TEH TECTWD 6 AV3 +0.02 TEH TECTWD 9 AVI +0.00 TEH TECTWD 5 AV2 +0.00 TEH TECTWD 7 AV6 +0.00 TEH TECTWD 7 AV7 +0.00 TEH TECTWD 5 AV4 +0.00 TEH TECTWD 7 AV4 +0.00 TEH TECTWD 8 AVE +0.00 TEH TECTWD 8 AV6 +0.00 TEH TECTWD 11 AV7 +0.00 TEH TECTWD 6 AVG +0.13 TEN TECTWD 11 AVG +0.00 TEH TECTWD 10 AV7 +0.00 TEH TECTWD 6 AV8 +0.00 TEH TECTWD 6 AV4 +0.04 - TEH TECTWD 15 AVS +0.02 TEH TECTWD 10 AV2 -0.09 TEH TECTWD 7 AV4 +0.04 TEH TECTWD 11 AV5 +0.00 TEH TECTWD 14 AVG +0.09 TEH TECTWD 16 AV7 +0.00 TEH TECTWD 8 AVI +0.00 TEH TECTWD 10 AV3 +0.00 TEH TECTWD 7 AV4 +0.00 TEH TECTWD 8 AVG +0.00 TEH TECTWD 9 AV7 +0.00 TEH TECTWD 8 AV8 +0.00 TEH TEC

CAL #

131313134421111155555588887777.

88888814141414141818181818444422222222222666666

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL610UL610UL61OLL610UL610UL61OUL610UL61001.610UL61OUL610UL610UL61oUL610Lt610UL610UL610UL61OUL610UL61oUL610UL61OUL61OUL61oUL610UL610UL61oUL61UL61sUL610UL61oUL610UL61oUL61OUL61OUL610UL61oUL61oUL61oUL610UL61oUL61oUL61oUL61OUL61oUL610UL61oUL610ULGlOUL

61oUL610UL61oULG1OUL61oUL610UL610UL610UL61oUL610UL61oUL

Page 93: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 28, Page 18 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

92 89 0.150.13

92 91 0.200.100.15

92 93 0.130.150.260.12

92 95 0.150.200.360.160.23

92 97 0.120.150.12

92 99 0.150.140.150.21

92 101 0.170.21

93 72 0.150.14

93 74 0.180.14

93 76 0.1593 80 0.16

0.170.17

93 82 0.200.180.200.25

93 84 0.250.280.220.230.230.21

93 86 0.170.390.310.260.200.32

93 88 0.250.290.290.300.17

93 90 0.170.140.210.19

93 92 0.150.180.13

DEG CHN

141 P2140 P2134 P2147 P2149 P2149 P2146 P2135 P2127 P2125 P2125 P2116 P2118 P2117 P2119 P278 P2105 P2128 P2119 P2135 P2120 P2109 P2136 P2111 P2100 P2135 P2134 P2133 P2106 P2109 P2118 P297 P268 P2121 P2107 P2114 P2109 P298 P2131 P288 P2105 P275 P2101 P2107 P2117 P2101 P2105 P2106 P2123 P2127 P2120 P2132 P2116 P2105 P2126 P2102 P267 P2137 P2117 P2

IND %TW

TND 7TWO 6TWO 8TWDO5TWO 6TWO 6TWO 7TWD 10TWDO5TWO 6TWO 8TWO 13TWO 7TWO 9TWD 5TWO 6TWDO5TWO 6TWO 6TWO 6TWO 8

TWO 7TWO 8TWD 7TWD 7

TWD 8TwO 6TWO 7TWO 7

TWO 8TWO 8TWO 9TWJ 8TWO 9TWD 10

TW]3 11TWO 11TWO 9TWO 10TWO 10TWO 9TWO 7TWO 14TWO 11TWO 10TND 8TND 12TND 9TND 11TND 11TWO 11TWO 7TWO 7TWO 6

TWO 8TWO 8TWO 6TWO 7TND 5

LOCATION

AV3 -0.24AV4 +0.00AV3 +0.09AV4 +0.04AVG +0.02AV4 +0.07AV5 +0.07AV6 +0.13AV7 +0.00AV2 +0.00AV3 +0.07AV4 +0.02AVS +0.11AV6 +0.07AV2 +0.07AV3 +0.07AV4 -0.02AV4 +0.00AV5 +0.00AV7 +0.00AV8 +0.00AV2 +0.00AV5 +0.00AVS +0.02AV6 +0.04AV4 +0.04AV2 +0.04AV6 +0.22AVS +0.00AV6 +0.00AV7 +0.00AV2 +0.00AV3 +0.00AVS +0.00AVG +0.00AV2 -0.09AV4 +0.07AVS +0.09AV6 +0.15AV7 +0.04AV8 +0.11AV2 +0.00AV3 +0.00AV4 +0.00AV5 +0.00AV6 +0.00AV7 +0.00AV2 +0.00AV3 +0.00AV5 +0.00AVG +0.00AV7 +0.00AV2 +0.04AV4 +0.00AV5 +0.00AV7 +0.11AV2 +0.29AV5 +0.00AV6 +0.18

EXT EXT

TEN TECTEE TECTEN TECTEN TECTEN TECTEN TECTEE TECTEE TECTEN TECTEN TECTEN TECTEl TECTEH TECTEE TECTEN TECTEN TECTEN TECTER TECTEN TECTEN TECTEN TECTEE TECTEN TECTEE TECTEE TECTEN TECTER TECTEN TECTEE TECTEN TECTEN TECTEN TECTEE TECTEE TECTEE TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEE TECTEN TECTEE TECTEN TECTEN TECTEN TECTEN TECTEE TECTEN TEC

UTIL 1 UTIL 2 CAL #

888888888

1414141414141414181818181818443332222222222222666666777777777777

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

61 013I=

610UL610UL610UL610UL610UL610UL610UL610UL610ULSlOUL610ULT61011UL6101L1610UL610UL6100UL610UL610UL610UL610UL61001.610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL610UL61013L61013l1610UL610UL610UL610UL610UL610UL610UL6101L1610UL610UL610UL610UL610UL610UL61001.610UL610UL610UL610UL6101L3610UL610UL

Page 94: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

ISt. Lucie Unit 2

Steam Generator Tube Inspection ReportAttachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 19 of 40

SG 26 Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

93 94 0.190.430.170.190.330.180.14

93 96 0.1993 98 0.17

0.320.150.30

93 100 0.210.25

93 104 0.1593 112 0.1594 69 0.1494 73 0.2294 81 0.15

0.290.28

94 83 0.190.270.240.17

94 85 0.190.520.240.230.22

94 87 0.170.320.350.350.310.32

94 89 0.160.230.120.130.14

94 91 0.210.13

94 93 0.100.22

94 95 0.400.290.400.17

94 97 0.350.17

94 99 0.220.210.230.29

94 105 0.1495 80 0.1795 84 0.31

0.400.430.270.350.25

DEG CHN

115 P2118 P2112 P2124 P2111 P276 P2110 P290 P2132 P2118 P2115 P2112 P2112 P2113 P2110 P2104 P2126 P2134 P2100 P2126 P2115 P2143 P2121 P2113 P2114 P2128 P2124 P2124 P2137 P2134 P281 P293 P2100 P2117 P2102 P288 P2112 P2118 P2108 P2126 P292 P2132 P2130 P242 P2108 P2126 P2110 P2115 P2112 P2113 P2102 P294 P2130 P2118 P2121 P2110 P2102 P2137 P2128 P2118 P2134 P2128 P2127 P2

IND %TW

TWD 7TWD 14TWD 7TWD 7TWD 12TWD 7TWD 6TWD 8TWD 7TWD 12TWD 7TWD 12TWD 8TWD 10TWD 7TWD 7TWD 6TWD 9TWD 6TWD 11TWD 11TWO 8TWD 11TWD 10TWD 7TWD 8TWD 17TWD 10TWD 10TWDN 9TWD 7TWD 11TWD 12TWD 12TWD] 11TWD 11TWD 6TWD 9TWO 5TW] 5TWD 6TWO 8TWN 5TWD 4TWD 8TWD 14TWD 11TWND 14TwD 7TWD 12TWD 7TWN 9TWD 8TWD 9TWD 11TWD 6TWD 7TWD 12TWD 15TWD 15TWN) 11TWD 13TWO 10

LOCATION

AV2 +0.00

AV3 +0.00AV4 +0.00AV5 +0.00AVG +0.00AV7 +0.00AVI -0.04AV3 +0.00AV2 +0.00AV3 +0.00

AV4 +0.00AV7 +0.00AV2 +0.00AV7 +0.09AV3 +0.00AV4 -0.04AV3 +0.00AVI +0.00AV3 +0.22AV4 +0.00AVG +0.13AV3 +0.00AV5 +0.18AV4 +0.15AVB +0.00AVI +0.04AV2 +0.07AV3 +0.04AV4 +0.07AV7 +0.04AV2 +0.02AV3 +0.13AV4 +0.09AVS +0.09AVG +0.04AV7 -0.02AV2 -0.13AV3 +0.07AV4 -0.11AV5 +0.22AV7 +0.24AVG +0.11

AV7 -0.11AV2 -0.13AV4 +0.00AV2 +0.00AV3 +0.00AV4 +0.00AV5 +0.00AV2 +0.00AV3 +0.00AV3 +0.09AV4 +0.00AV5 +0.09AVG +0.02AV2 -0.04AV5 +0.02AV2 +0.02AV3 +0.02AV4 +0.09AVS +0.00AV7 +0.07AV8 +0.27

EXT EXT

TEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

UTIL 1 UTIL 2 CAL #

1313131313131313171717171717202793111111111111

555

75

7777777777

13131313131317

17

17171911911111

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL

61OUL610OUL610UL610UL61OUL610ULGO1UL610UL61OUL610UL61OUL61OUL610UL610UL610UL610UL610UL610UL610UL6101U11

61011L610UL610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL610UL610UL610UL6101U1610UL610UL610UL610UL610ULT610UL6101.UL610UL610UL610UL61011610UL610UL610UL61OUL610UL610UL610UL610UL610UL610UL610UL6101L610UL610UL

Page 95: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 20 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG

95 86 0.55 1090.47 1130.33 1050.28 930.46 1150.22 59

95 88 0.26 1330.18 1430.20 1420.36 1300.30 1280.19 141

95 90 0.18 1030.22 1190.14 120

95 92 0.16 1410.17 1370.11 108

95 94 0.27 1180.30 1200.26 1080.20 1060.12 128

95 96 0.12 1150.23 101

95 98 0.21 1360.18 136

95 100 0.26 1300.30 1320.26 950.17 121

96 59 0.14 12496 73 0.26 98

0.18 11796 75 0.14 9496 79 0.18 112

0.15 8696 81 0.19 120

0.17 950.16 1100.16 85

96 83 0.29 1020.18 430.18 670.29 980.27 1160.21 80

96 85 0.38 1150.21 970.37 1060.17 72

96 87 0.29 1080.39 1060.23 1210.17 1210.34 1070.34 105

96 89 0.15 1190.18 1290.22 1330.23 1350.16 101

CHN IND %TW LOCATION

P2 TWD 17 AV2 +0.09P2 TWD 15 AV4 +0.09P2 TW]) 12 AV5 +0.18P2 TWD 10 AV6 +0.02P2 TWD 15 AV7 -0.02P2 TWD B AV8 +0.00P2 TWND 10 AV2 +0.09P2 TWD 8 AV3 +0.09P2 TWD 9 AVS +0.11P2 TWD 13 AVE +0.07P2 TWD 11 AV7 +0.09P2 TWD 8 AV8 +0.13P2 TWD 7 AV4 +0.00P2 TWD 8 AVS +0.16P2 TWD 6 AVE +0.16P2 TWD 7 AV2 +0.04P2 TWD 7 AV4 +0.04P2 TWD 5 AV6 -0.02P2 TWN 10 AVI +0.02P2 TW]D 11 AV2 +0.04P2 TWD 10 AV3 -0.02P2 TWD 8 AV6 +0.02P2 TWD 5 AV7 +0.02P2 TWD 5 AV2 +0.22P2 TWD 9 AV3 -0.02P2 TWD 8 AV2 +0.00P2 TWD 8 AV3 +0.00P2 TWD 10 AV2 +0.00P2 TWD 11 AV3 +0.00P2 TWD 10 AV4 +0.00P2 TWN 7 AV5 +0.00P2 TWD 6 AV4 +0.00P2 TWD 12 AV4 +0.00P2 TWD 8 AV5 +0.00P2 TWD 7 AV3 +0.00P2 TWN 8 AVG +0.00P2 TWD 7 AV7 +0.00P2 TWD 8 AV4 +0.00P2 TWD 8 AV6 +0.00P2 TWD 7 AV7 +0.00P2 TWD 7 AV8 +0.00P2 TWD 12 AVI +0.00P2 TWD 8 AV2 +0.00P2 TWD 8 AV3 +0.00P2 TWD 12 AV5 +0.00P2 TWD 11 AV7 +0.00P2 TWD 9 AV8 +0.00P2 TWD 15 AV4 +0.04P2 TWO 9 AVS +0.13P2 TWO 14 AV6 +0.09P2 TWD 8 AV8 -0.07P2 TWD 11 AV2 +0.00P2 TWD 13 AV3 +0.00P2 TWD 9 AV4 +0.00P2 TWD 7 AV5 +0.00P2 TWD 12 AVE +0.18P2 TWD 12 AV7 +0.00P2 TWD 7 AV4 +0.00P2 TWD 8 AV5 +0.00P2 TWD 9 AV6 +0.00P2 TWD 9 AV7 +0.00P2 TWD 7 AV8 +0.18

EXT EXT UTIL 1 UTIL 2

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TEC

CAL #

555555888888

777

.8881414141414141418181818181815444222222222222222266666688888

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL

610UL610UL610UL

610UL61OUL610UL610UL

610UL61OUL610UL610UL610UL6100LT61001,610UL610UL610UL1610UL0610UL610UL610UL

610UL610UL610LT610UL610UL610UL610UL610UL610UL610UL610UJL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6 10UL610UL610UL610UL61OUL

610UL610UL610UL610UL

E10ut

Page 96: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 21 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

96 91 0.100.150.150.130.14

96 93 0.250.100.180.14

96 95 0.150.140.230.24

96 97 0.340.11

97 58 0.210.17

97 60 0.180.17

97 70 0.1297 82 0.19

0.190.170.270.17

97 84 0.320.350.230.370.440.27

97 86 0.330.480.270.300.19

97 88 0.130.27

97 90 0.140.190.190.16

97 92 0.240.140.120.23

97 94 0.170.200.230.24

97 96 0.180.170.19

97 98 0.160.260.200.190.19

97 100 0.210.200.28

98 67 0.14

DEG

90114114148138136152126123126110120108

1041281281321171371139082101103829210010610912710211211812511812513313088919112011773659511580ill101127104861401271201249089104113127

CHN

P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2

IND %TW

TWN 5TWN 7

TWN 6

TWD 6TWO 6TN 10TWN 5TWD 8TWN 6TWD 6TTW 6TwN 9TWN 10TWD 13TWN 5TWN 9TWD 8TWN 8TWN 8TW] 5TW] 8TWD 8TWN 8TW 11

TWN 8TWD 13TN] 14TWD 10

TWD 14TWN 16T I 11TN] 12TWO 16TN 10TWO 11TWD 8TWD 5TWO 10TW] 6TW] 7

TW] 7TWD 6TWD 9TWD 6TW] 5

TWN 9TWN 7TWO 8TWN 9TWN 9TWO 7TWN 7TW] 7TWD 7TN] 10TW] 8TW] 8TWN 8TWN 8TW] 8T i] 11TWD 6

LOCATION

AVi +0.02AV2 +0.07AV3 -0.04AV4 -0.02AV5 +0.02AV2 +0.07AV3 +0.02AV4 +0.04Ave +0.07AV2 +0.00AV3 +0.04AV5 +0.07AVG +0.07AV3 +0.04AV4 +0.13AV4 +0.04AV5 +0.04AV5 +0.11AV3 +0.04AV2 +0.00AV2 +0.00AV3 +0.00AV4 +0.00AVG +0.00AV7 +0.00AV2 +0.07AV3 -0.09AV4 +0.07AV5 -0.07AV6 -0.07AV7 +0.18AV2 +0.00AV4 +0.00AVS +0.00AVG +0.00Ave +0.00AVS +0.20AVG +0.07AV7 +0.09AVG +0.15AV5 +0.13AV4 +0.11AV2 +0.00AVG +0.27AV7 +0.00AVe +0.00AV2 +0.00AV3 +0.00AVG +0.00AV7 +0.00AVI +0.00AV3 +0.00AV4 +0.00AV2 +0.00AV3 +0.00AV5 +0.00AVG +0.00AV7 +0.00AV4 +0.00AV5 +0.07AVG +0.04AVi +0.00

EXT EXT

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

UTIL 1 UTIL 2 CAL #

888888888

141414141414161616169222222222226666677808o808077771313131313131317171717171717179

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

61OUL610UL610UL610UL610UL610UL610UL610UL61OUL61001.610UL61001L61OUL610UL6100LT61001L61200L610UL610UL610UL610UL610UL61OUL610ULGlOUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61OUL61001610UL610UL610UL6101UL610UL610UL610UL610UL610UL610UL61001L61001.610UL610UL610UL610UL610UL610UL610UL

Page 97: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 22 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

98 69 0.1498 81 0.22

0.1598 83 0.36

0.340.48

98 85 0.170.520.330.310.17

98 87 0.270.300.370.500.520.34

98 89 0.2098 91 0.28

0.2598 93 0.09

0.1798 95 0.16

0.2398 97 0.4198 99 0.1998 101 0.2098 103 0.1499 68 0.15

0.1299 72 0.1599 76 0.1699 82 0.4599 84 0.35

0.340.340.310.49

99 86 0.250.630.410.410.28

99 88 0.160.180.210.27

99 90 0.160.160.110.25

99 92 0.170.390.250.410.23

99 94 0.120.240.320.130.16

99 96 0.11

DEG CHN

117 P2116 P2115 P2116 P2113 P2119 P2135 P2126 P2118 P2132 P2138 P2106 P2122 P2108 P2110 P2106 P280 P2111 P2109 P2123 P2122 P2128 P2124 P2112 P2Il P2118 P2125 P284 P270 P2120 P2127 P299 P2130 P2125 P2123 P2116 P2135 P2130 P287 P2113 P2104 P2107 P299 P2133 P2125 P2142 P2141 P2131 P2122 P283 P2128 P2130 P2123 P2132 P2128 P2136 P296 P2120 P2105 P2112 P2107 P2138 P2

IND %TW

TWO 6TWD 9TWD 6

TWD 14TWD 13TWD 16TWD 7

TWD 18TWD 13TWD 12TWD 7TWD 10TWD 11TWD 13TWD 16TWD 16TWD 12TWD 8TWD 10TWD 10TWD 4TWO 7TWD 6

TWD 9TWO 14TWD 8TwD 8

TWO 6

TWD 8TWD 6TWD 7TWD 8TWD 16TWD 13TWO 13TWD 13TWO 12TWD 17TWD 9TWD 19TWO 14TWO 14TWD 10TWD 7

TwD 8TwD 9TW 11TWO 6TWD 6

TWDO5TWD 9TWD 7TWO 14TWD 10TWD 15TWD 9TWDO5TWO 9TWO 12TWD 6

TWD 7TWD 5

LOCATION

AV2 +0.00AV3 +0.02AV4 -0.04AV3 +0.00AV4 +0.00AV5 +0.00AVi +0.02AV2 +0.04AV3 +0.07AV4 +0.07AV6 +0.09AV3 +0.11

AV4 -0.04AV5 +0.09AV6 +0.20AV7 +0.00AV8 -0.07AV6 +0.07AV3 +0.02AV4 +0.00AVI -0.20AV2 +0.02AV2 +0.00AV8 +0.00AV2 +0.00AV2 +0.00AV7 +0.09AV2 +0..18AV2 +0.02AV3 +0.00AV5 +0.13AV6 +0.00AV3 +0.00AV2 +0.07AV3 +0.04AV4 +0.00AV5 +0.00AVG +0.07AVI +0.09AV4 +0.07AV5 +0.11AVG +0.02AV8 +0.00AV3 +0.09AV4 +0.16AV5 +0.11AVG +0.18AV4 -0.18AV5 +0.13AVG +0.22AV7 +0.04AVl +0.13AV2 +0.04AV3 +0.02AV4 +0.04AVG +0.16AVI +0.04AV2 -0.02AV3 +0.02AVG +0.04AV7 +0.07AVl -0.02

EXT EXT

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC.TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

UTIL 1 UTIL 2 CAL #

911111111

1

55

7777777

13131317171910

10

3411111155SSS

888

8777788888

141414141414

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UM610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL0610UL610UL610UL610UL610UL610UL61001

61001.61001.61001.6100UL6100U.6100U.61001.61001.61001.610U3161001.61001.61001L610U1.610UL.610U1.61001.61001.61001.61001.61001.61001.610U1.61001.61001.61001.61001.61001.61001.610U1.61001.61001.61001.61001.61001.61001.610UL

610UL

Page 98: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 23 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

99 102 0.170.10

100 79 0.200.20

100 81 0.280.150.230.22

100 83 0.180.470.570.200.180.21

100 85 0.270.360.200.320.23

100 87 0.260.260.17

100 89 0.160.25

100 91 0.13100 95 0.14

0.130.170.200.27

100 97 0.280.240.12

100 99 0.230.250.620.16

100 103 0.14101 82 0.42

0.350.400.370.170.26

101 84 0.160.520.190.390.480.28

101 86 0.270.300.390.210.40

101 88 0.100.210.22

DEG

133118909589108109102581161219111391961137998ill11913110313513615110167115106100127110127124131118136124117931231239011074106118106110113112101

108130ill77116120

CHN

P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2

IND %TW

TWO 7TWO 5TWO 9

'rD 9TWO 11TWO 7TWO 10TWO 9TWO 8TWO 17TWD 19TWO 9TWD 8

TWO 9TWO 11TWO 14TWO 9TWO 13TWO 10TWO 10TWO 10TWO 7TWO 7TWD 10TWO 6TWD 6TWD 6TWD 7TWO 8TWO 10TWD 11TWD 9TWO 5TWO 9TWO 10TWO 19TWO 7TWO 6TWO, 16TWO 14TWO 15TWO, 14TWO 8TWO 11TWO 7TWO 18TWO 8

TWO 15TWO 17TED 12TWO 10TWO 11

TWO 13TWO 8TWO 14TWO, 4

TWO 8TWD 8

LOCATION

AVI +0.00AV2 +0.00AV6 +0.00AV7 +0.00AV3 +0.00AV4 +0.00AVS +0.00AV6 +0.00AV2 +0.00AV3 +0.00AV4 +0.00AVG +0.00AV7 +0.00AV8 +0.00AV2 -0.07AV3 -0.02AVG +0.11AV7 +0.07AV4 +0.11AV5 +0.00AVG +0.22AV7 +0.00AV3 -0.04AV4 -0.20AV7 +0.02AV2 +0.02AV3 +0.09AV4 +0.07AV5 +0.02AV7 +0.02AV2 +0.09AV3 +0.07AV7 +0.00AV2 +0.00AV3 +0.00AV4 +0.00AV6 +0.00AV2 +0.00AV2 +0.00AV3 +0.00AV4 +0,00AV5 +0.00AVG +0.00AV7 +0.00AVl +0.04AV4 +0.37AV5 +0.09AV6 -0.26AV7 -0.07AV8 -6.02AV2 +0.00AV4 +0.00AVS +0.00AVG +0.00AV7 +0.00AV2 -0.13AV5 +0.11

AVG +0.07

EXT EXT

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

UTIL 1 UTIL 2 CAL #

202022222222222222222666

8881414141414141414181818182022222222222266666777

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001L610UL610UL610UL610UL61OULGO1UL610UL610UL61OOL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610ULlO0UL

610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

Page 99: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 24 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

101 90 0.260.160.140.390.170.16

101 92 0.220.300.180.100.19

101 94 0.170.180.240.19

101 96 0.310.250.150.19

101 98 0.240.340.270.16

101 100 0.21101 104 0.17

0.15101 112 0.14

0.13102 65 0.16102 73 0.16102 75 0.15102 81 0.35

0.240.210.350.17

102 83 0.310.27

102 85 0.280.350.420.610.17

102 87 0.210.270.430.480.260.20

102 89 0.140.240.270.18

102 91 0.12102 93 0.16

0.16102 95 0.19

0.170.190.160.18

DEG

90981101088895122101125931091087410411010810412212412112511393ill125108108108109101128107136140124122123130130124130127117103108108102857690120112931078312612610110710678

CHN IND %TW LOCATION

P2 TWD 10 AV8 +0.07P2 TWD 6 AV7 +0.13P2 TWD 6 AV6 +0.17P2 TWD 13 AV5 +0.13P2 TWD 7 AV2 +0.00P2 TWD 6 AV4 +0.00P2 TWD 8 AV2 +0.00P2 TWD 11 AV3 +0.00P2 TWD 7 AV5 +0.00P2 TWD 4 AV6 +0.20P2 TWD 7 AV7 -0.22P2 TWD 7 AV2 +0.00P2 TWD 7 AV3 +0.00P2 TWD 9 AV6 +0.00P2 TWD 7 AV7 +0.00P2 TWD 11 AV2 +0.00P2 TWD 10 AV3 +0.00P2 TWD 6 AV4 +0.00P2 TWD 7 AV5 +0.00P2 TWD 10 AVI +0.02P2 TWD 13 AV2 +0.00P2 TWD 11 AV3 +0.00P2 TWD 7 AV8 +0.00P2 TWD 8 AV2 +0.00P2 TWD 7 AV4 +0.00P2 TWD 7 AVS +0.00P2 TWD 6 AV2 +0.20P2 TWD 6 AV3 +0.09P2 TWD 7 AV4 +0.07P2 TWD 7 AVS -0.02P2 TWD 7 AV2 +0.00P2 TWD 13 AV3 +0.07P2 TWD 10 AV4 +0.07P2 TWD 9 AVS +0.09P2 TWD 13 AV6 +0.07P2 TWD 7 AV7 +0.07P2 TWD 12 AV4 +0.00P2 TWD 11 AV5 +0.00P2 TWD 11 AVI +0.07P2 TWD 13 AV2 +0.09.P2 TWD 15 AV6 +0.11P2 TWD 19 AV7 +0.07P2 TWD 7 AV4 +0.04P2 TWD 8 AVI -0.07P2 TWD 10 AV2 +0.00P2 TWD 14 AVS -0.04P2 TWD 15 AV6 +0.02P2 TWD 10 AV7 +0.18P2 TWD 8 AV8 +0.16P2 TWD 6 AV4 -0.18P2 TWD 9 AV5 +0.20P2 TWD 10 AV6 +0.07P2 TWD 7 AV7 +0.00P2 TWD 5 AV3 -0.07P2 TWD 6 AVi -0.02P2 TWD 6 AV2 +0.00P2 TWD 8 AV2 +0.00P2 TWD 7 AV3 +0.00P2 TWD 8 AV4 +0.00P2 TWD 6 AVS +0.00P2 TWD 7 AV7 +0.00

EXT EXT UTIL 1 UTIL 2

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

CAL 6

80

808080

808077777

13131313131313131717171717

2020272711

3311111111111155555577777771313131313

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL61oUL610UL61OUL61oUL610MU610lUL610Lt61oUL61OUL61OUL610MU610UM61sUL61OUL610UL610UL61OUL61SUL61OUL610UL610UL610UL610UL61oUL61oUL61oUL610Lt610UL610UL61oUL610UL610UL61SUL610UL61oUL61oUL610ULt61SUL61oUL61SUL610UL61OUL61oUL61oULsioUL61SUL61SUL61oUL610ULT610UoL61oUL61oUL610UL610Lt61 oUL610LT61OUL610UL610UL610UL

Page 100: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 25 of 40

SG 2B Wear Indications 1-19% TWID at AVB locations (continued)

ROW COL VOLTS

102 97 0.170.350.24

102 109 0.16103 60 0.10103 74 0.18

0.240.190.16

103 84 0.180.380.420.410.270.280.340.20

103 86 0.380.200.410.350.26

103 88 0.210.270.380.200.35

103 90 0.200.110.100.19

103 92 0.150.22

103 94 0.130.37

103 96 0.12103 100 0.21104 73 0.17104 77 0.14104 81 0.15

0.310.22

104 83 0.420.330.33

104 85 0.240.250.280.21

104 87 0.150.28

104 89 0.180.180.170.21

104 91 0.120.26

104 93 0.20104 95 0.14

0.220.170.11

0.11

DEG CHN

123 P2113 P290 P2122 P278 P298 P2103 P2110 P288 P2122 P2127 P2120 P2125 P2131 P2116 P2135 P2139 P2115 P295 P2116 P2103 P2102 P2131 P2124 P2127 P2131 P2131 P2141 P292 P2136 P2108 P2144 P2134 P2131 P2113 P2113 P2120 P2103 P2102 P292 P2108 P2112 P2108 P2126 P2103 P2101 P2108 P2100 P283 P286 P2110 P2132 P2141 P2138 P2137 P2129 P2119 P2142 P2103 P2123 P2116 P2106 P2144 P2

IND %TW

TWD 7TWD 12TWD 9TWD 7TWD 5TWD 9TWD 11TWD 9TWD 8TWD 8TWD 14TWD 15TWD 15TWD 11TWD 11TWD 13TWD 8TWD 13TWD 8TWD 14TWD 12TWD 10TWD 9TWD 11TWD 14TWD 8TWD 13TWD 8TWD 5TWD 4TWD 8TWD 7TWD 9TWD 6TWD 13TWD 5TWD 8TWD 8TWD 7TWD 7TWD 12TWD 9TWD 16TWD 13TWD 13TWD 10

TWD 10TWD 12TWD 9TWD 6TWD 10TWD 8TWD 8TWD 7TWD 9TWD 5TWD 10TWD 8TWD 6TWD 9TWD 7TWD 5TWD 5

LOCATION

AVI +0.00AV2 +0.00AV3 +0.00AV2 +0.00AV4 -0.20AV3 +0.00AVS +0.00AV6 +0.00AV7 +0.00AVI +0.07AV2 +0.02AV3 +0.11AV4 +0.02AV5 +0.02AVG +0.00AV7 +0.00AV8 +0.00AV2 +0.02AV3 +0.02AV4 +0.16AVS +0.00AV7 -0.09AV3 +0.11AV5 +0.27AVG +0.09AV7 +0.13AV8 +0.13AV2 +0.00AV3 -0.11AV4 -0.04AVS +0.07AVI +0.02AV2 +0.04AV2 +0.04AV3 +0.07AV5 +0.02AV7 +0.00AV2 +0.00AV7 +0.02AV5 +0.00AVG +0.00AV7 +0.00AV4 +0.00AVS +0.00AV8 +0.00AV4 -0.04AVS -0.09AVG +0.04AV7 +0.00AV2 +0.00AV5 +0.00AV4 +0.00AVS +0.00AVG +0.00AV7 +0.00AVI -0.02AV2 -0.04AV3 +0.09AVI +0.13AV2 +0.00AV3 +0.09AV4 -0.02AV7 +0.09

EXT EXT

TEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

UTIL 1 UTIL 2 CAL # LEG

13 COLD13 COLD13 COLD23 COLD15 COLD4 COLD4 COLD4 COLD4 COLD1 COLD1 COLD1 COLD1 COLD1 COLD1 COLD1 COLD1 COLD5 COLD5 COLD5 COLD5 COLD5 COLD8 COLD8 COLD8 COLD8 COLD8 COLD7 COLD7 COLD7 COLD7 COLD8 COLD8 COLD14 COLD14 COLD14 COLD18 COLD4 COLD4 COLD2 COLD2 COLD2 COLD2 COLD2 COLD2 COLD2 COLD2 COLD2 COLD2 COLD6 COLD6 COLD8 COLD8 COLD8 COLD8 COLD8 COLD8 COLD8 COLD14 COLD14 COLD14 COLD14 COLD14 COLD

PROBE

610UL610UL610UL610UL61OUL610UJL6100LT6100UL610UL610UL610UL610UL610UL6101UL610UL610UL610UL610UL610UL610UL61001.

6100.L610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6101UL610UL610UL610UL61001.610UL610UL610UL6100LT610UL610UL6101UL610UL610UL610UL610UL610UL610UL6100L610UL610UL610UL610UL61OUL610UL61001L610UL61OUL610UL

Page 101: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 26 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

104 97 0.18104 99 0.17

0.220.14

105 78 0.23105 82 0.51

0.170.160.280.18

105 84 0.170.200.490.200.290.20

105 86 0.350.200.460.370.350.510.23

105 88 0.250.260.35

105 90 0.120.150.220.130.260.14

105 92 0.120.110.250.120.10

105 94 0.180.250.160.19

105 96 0.200.310.21

105 98 0.210.280.16

106 81 0.240.25

106 83 0.440.310.27

106 85 0.280.470.29

106 87 0.310.320.290.480.220.25

DEG

1391341341421241026987916669112102781058711912511511012012010310512211613712411I

126133145131117925673999298100105ill117116187124134124126130129117132989910510890

83

CHN

P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2

IND %TW

TWD 8TWD 7TWD 9TWD 6TWD 10TWD 18TWD 8TWD 7TWD 11TWD 8TWD 8TWD 9TWD 17TWD 9TWD 12TWD 9TWD 13TWD 8TWD 15TWD 13TWD 12TWD 16TWD 9TWD 9TWO 10TWD 12TWD 5TWD 7TWD 9TWD 6TWD 10TWD 6TWD 5TWD 5TWD 10TWD 5TWD 4TWD 7TWD 10TWD 6TWD 8TWD 8TWD 11

TWD 8TWD 8TWD 11TWD 7TWD 10TWD 10TWD 16TWD 12TWD 11TWD 11TWD 16TWD 12TWD 11TWD 11TWD 10TWD 15TWD 8TWD 9

LOCATION

AV2 +0.02AV2 +0.00AV3 +0.00AVG +0.00AV2 +0.11AV3 +0.00AV4 +0.00AV5 +0.00AV6 +0.00AV7 +0.00AVi +0.09AV2 +0.00AV3 +0.04AV4 -0.02AVS +0.13AV7 +0.13AV2 +0.00AV3 +0.00AV4 +0.00AVS +0.00AVE +0.00AV7 +0.00AV8 +0.00AVIl +0.00AV2 +0.16AV3 +0.00AV2 +0.09AV4 +0.07AVS +0.09AV6 +0.02AV7 +0.09AV8 +0.11AVi +0.00AV2 +0.20AV3 +0.11

AV4 -0.11AV7 -0.18AV3 +0.00AV4 +0.00AVS +0.00AVE +0.00AV2 +0.00AV3 +0.00AVE +0.00AV2 +0.04AV3 +0.02AV4 +0.02AV6 +0.00AV7 +0.07AV3 +0.00AV4 +0.00AV5 +0.00AVI +0.00AV2 -0.02AV6 +0.04AVi +0.24AV2 +0.04AV5 +0.02AV6 -0.04AV7 +0.02AV8 -0.13

EXT EXT

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEN TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

OTIL 1 UTIL 2 CAL #

1418181832222222222266666667778888887777

713131313131313171717111111115S555S

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

61OUL61OUL610UL61001,

61OUL610UL610014610UL610UL610UL6100LT610UL0610UL610UL610UL6100L,610UL610UL610UL610UL,610UL610UL6101L610UL610UL610UL610UL6100L

61001i610UL610UL610UL610UL610UL610UL610UL610UL610UL6100L610UL610UL61001610UL6100L6100L610UL6100L610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001

61001

Page 102: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 27 of 40

SG 26 Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG

106 89 0.18 1220.25 1200.22 1200.33 95

106 91 0.29 118106 93 0.31 125

0.24 120106 95 0.24 122106 97 0.15 102

0.30 1220.40 123

107 68 0.13 133107 74 0.18 73107 76 0.19 71107 82 0.33 125

0.18 1380.19 1260.15 1260.21 130

107 84 0.33 1250.34 1250.41 1350.30 135

107 86 0.33 1040.39 1090.49 1060.60 103

107 88 0.16 1430.19 1140.26 1300.34 1190.34 1300.18 1340.15 142

107 90 0.12 1340.21 1050.13 1200.25 1150.25 1050.16 133

107 92 0.28 1270.11 990.14 141

107 94 0.30 1050.13 750.12 115

107 98 0.26 1120.14 1160.19 1310.26 1260.16 122

107 100 0.17 139107 102 0.13 128

0.25 119108 77 0.21 89108 81 0.14 94108 83 0.17 110

0.35 1040.30 1070.25 1000.22 95

CHN IND %TW LOCATION

P2 T=D 7 AV4 +0.00P2 TWD 9 AV4 +0.00P2 TWD 8 AV5 +0.00P2 TWD 12 AV7 +0.00P2 TWO 11 AV7 +0.00P2 TWD 11 AV2 +0.07P2 TKD 9 AV3 +0.02P2 TWD 9 AV2 +0.00P2 TWD 6 AVI +0.00P2 TWD 11 AV2 +0.00P2 TWD 14 AV3 +0.00P2 TWD 5 AV2 +0.00P2 TED 8 AV3 +0.00P2 TWD 9 AV3 +0.00P2 TWD 13 AV3 +0.00P2 TWD 8 AV4 +0.09P2 TWD 8 AVS +0.02P2 TWD 7 AVG +0.00P2 TWD 9 AV7 +0.11P2 TWD 13 AV3 +0.04P2 TWD 13 AV4 +0.00P2 TWD 15 AVS +0.00P2 TWD 12 AV7 +0.00P2 TWD 12 AV2 +0.07P2 TWD 13 AV5 +0.00P2 TWD 16 AV6 +0.02P2 TWD 18 AV7 +0.04P2 TWD 7 AVI +0.16P2 TWD 8 AV2 +0.20P2 TWD 10 AV3 +0.00P2 TWD 13 AV4 +0.00P2 TWD 13 AV5 +0.00P2 TWD 8 AVG +0.00P2 TWD 6 AV7 +0.09P2 TWD 5 AVl +0.16P2 TWD 8 AV2 +0.04P2 TWD S AV3 -0.13P2 TWD 9 AV4 +0.07P2 TWD 9 AVS +0.00P2 TWD 6 AV7 +0.16P2 TWD 11 AV2 +0.00P2 TWD 5 AV6 +0.13P2 TWD 6 AV7 +0.24P2 TWD 11 AV2 +0.07P2 TWD 6 AV3 +0.04P2 TWD 5 AV4 +0.07P2 TWD 10 AV2 +0.00P2, TWD 6 AV3 +0.00P2 TWD 8 AV4 +0.00P2 TWD 10 AV5 +0.00P2 TWD 7 ,AV6 +0.07P2 TWD 7 AV3 +0.00P2 TWD 6 AV3 +0.00P2 TWD 10 AV4 +0.00P2 TWE 10 AV2 +0.07P2 TWD 7 AV2 -0.02P2 TWD 8 AVi +0.00P2 TWD 14 AVS +0.00P2 TWD 12 AV6 +0.00P2 TWD 10 AV7 +0.00P2 TWD 10 AV8 +0.00

EXT EXT

TE= TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

UTIL I UTIL 2 CAL #

777777713131313944111111111

S

SSS88

58

88877

888

1414

42222

88

1818

1818

19194222222

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UM

61OUL61OUL610ULT610ULT

610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UyL610ULL610UL610UL610ULT610UL610UL610UL610ULT610UL610UL610UL610UL610UL610ULL610ULT610UL610UL610ULT610UL6 10UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610ULL

'610UL610UL610ULL610UL610UL610UL610UL610UL61OUL

610ULT

Page 103: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Repori

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 28 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

108 85 0.160.140.310.52

108 87 0.140.280.25

108 89 0.140.210.250.20

108 91 0.310.220.22

108 93 0.180.28

108 95 0.11

0.270.280.270.23

109 70 0.14109 76 0.23109 82 0.28

0.28109 84 0.35

0.300.220.520.290.440.27

109 86 0.290.540.310.490.540.24

109 88 0.180.20

109 90 0,200.240.170.28

109 92 0.160.140.240.110.10

109 94 0.310.21

109 96 0.16109 98 0.24

0.30109 100 0.32

0.240.220.200.17

109 112 0.12110 59 0.16

0.17

DEG CHN

76 P2120 P2117 P2119 P2110 P297 P295 P2149 P2137 P2129 P2130 P2130 P2132 P2131 P2140 P2126 P2110 P2117 P2118 P2122 P2112 P2138 P2136 P2106 P2117 P295 P296 P2103 P2101 P2102 P299 P2108 P2107 P2117 P2109 P2118 P2121 P295 P286 P2115 P289 P2120 P287 P2109 P287 P2136 P2129 P2138 P282 P2117 P2122 P2103 P2124 P2101 P2109 P297 P2105 P298 P287 P2101 P2119 P2126 P2

IND %TW

TWD 8TWD 7TWD 13TWD 19TWD 6TWD 10TWD 10TWD 6TWD 9TWD 10TWD 8TWD 12TWD 9TWD 9TWD 8TWD 11TWD 5TWD 11

TWD 11TWD 11TWD 9TWD 6TWD 10TWD 12TWD 12TWD 14TWD 12TWD 9TWD 18TWD 12TWD 16TWD 11TWD 11TWD 17TWD 11TWD 16TWD 17TWD 9TWD 7TWD 8TWD 8TWD 9TWD 7TWD 10TWD 6TWD 6TWD 9TWD 5TWD 4TWD 11TWD 8TWD 6TWD 9TWD 11TWD 12TWD 9TWD 9TWD 8TWD 7TWD 6TWD 7TWD 8

LOCATION EXT EXT

AVI -0.02 TER TECAV5 +0.00 TER TECAV6 +0.04 TER TECAV7 +0.02 TEN TECAV4 +0.00 TEH TECAVS +0.00 TER TECAV6 +0.00 TEH TECAV2 +0.00 TER TECAV5 +0.00 TER TECAVG +0.00 TEN TECAV7 +0.00 TEN TECAV3 -0.02 TEN TECAV4 +0.04 TEN TECAVS +0.07 TER TECAVI +0.02 TEN TECAV2 +0.07 TEN TECAV1 +0.11 TEN TECAV2 -0.02 TEN TECAV3 +0.07 TEN TECAV4 +0.00 TEN TECAV5 +0.00 TER TECAV3 +0.00 TEN TECAV4 +0.04 TER TECAV4 +0.00 TEN TECAV5 +0.00 TEN TECAVI +0.09 TEN TECAV2 +0.00 TEN TECAV3 +0.00 TEN TECAV4 +0.00 TEN TECAVG +0.00 TER TECAV7 +0.00 TEN TECAV8 +0.00 TEN TECAV2 +0.00 TEN TECAV4 +0.00 TEN TECAV5 +0.00 TEN TECAV6 +0.00 TEN TECAV7 +0.00 TEN TECAV8 +0.00 TEN TECAV2 +0.02 TEN TECAV3 +0.00 TEN TECAV8 +0.02 TEN TECAV6 +0.11 TEN TECAV4 +0.00 TEN TECAV3 +0.17 TEN TECAV2 +0.15 TEH TECAV3 -0.11 TEH TECAV4 +0.11 TER TECAV6 +0.11 TEH TECAV7 -0.15 TEN TECAV2 +0.00 TEN TECAV3 +0.00 TER TECAV2 +0.00 TEN TECAV2 +0.07 TEN TECAV3 +0.04 TEN TECAV2 +0.00 TEN TECAV3 +0.13 TEN TECAV4 +0.09 TER TECAV5 +0.11 TEN TECAV6 +0.09 TEN TECAV3 +0.13 TEH TECAV4 +0.07 TEN TECAV3 +0.04 TEN TEC

UTIL 1 UTIL 2 CAL #

2222666888888888

14141414149322222222266666677808080807777713131317171717171717271616

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL610UL610UL610UL61OUL610UL610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL

IO1UL6100L610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610ULT610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6100LT610UL610UL610UL610UL61OUL

Page 104: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Rev. 0Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1 SG 2B, Page 29 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG PROBE

110 75 0.17 122 P2 TWD 8 AVS +0.13 TEH TEC 3 COLD 610UL110 77 0.20 127 P2 TED 9 AV3 +0.04 TEN TEC 3 COLD 610UL110 83 0.43 124 P2 TED 15 AV4 +0.00 TEH TEC 1 COLD 610UL

0.36 125 P2 TWD 14 AV5 +0.00 TER TEC 1 COLD 610UL0.23 124 P2 TWD 10 AVG +0.00 TEH TEC 1 COLD 610UL

110 85 0.43 125 P2 TWD 15 AV3 +0.02 TEN TEC 1 COLD 610UL0.22 123 P2 TWD 9 AV4 +0.04 TEN TEC 1 COLD 610UL0.29 134 P2 TWD 12 AV5 +0.04 TEN TEC 1 COLD 6100L0.59 120 P2 TWD 19 AV7 +0.09 TER TEC 1 COLD 610UL

110 87 0.40 105 P2 TWD 14 AV3 +0.00 TEN TEC 5 COLD 610UL0.29 87 P2 TWD 10 AV5 +0.07 TEN TEC 5 COLD 610UL0.54 109 P2 TWD 17 AV6 +0.07 TEN TEC 5 COLD 610UL0.49 101 P2 TWD 16 AV7 +0.13 TEH TEC 5 COLD 610UL0.38 100 P2 TWD 13 AV8 +0.22 TEH TEC 5 COLD 610UL

110 89 0.17 101 P2 TWD 7 AV4 +0.00 TEH TEC 7 COLD 610UL0.64 113 P2 TWD 19 AV5 +0.04 TEN TEC 7 COLD 610UL0.28 90 P2 TWD 10 AV7 +0.00 TEN TEC 7 COLD 610UL0.12 103 P2 TWD 5 AV8 -0.11 TEH TEC 7 COLD 610UL

110 91 0.25 126 P2 TED 9 AV5 +0.09 TER TEC 7 COLD 610UL0.21 127 P2 TWD 8 AVG +0.00 TER TEC 7 COLD 61OUL0.26 104 P2 TWD 10 AV7 +0.00 TEH TEC 7 COLD 6100L0.10 124 P2 TWD 4 AV8 -0.20 TEN TEC 7 COLD 6100L

110 93 0.27 116 P2 TWD 10 AV2 +0.07 TEN TEC 7 COLD 610UL0.37 120 P2 TWD 13 AV4 +0.00 TEN TEC 7 COLD 610UL0.22 111 P2 TWD 8 AV7 +0.00 TEN TEC 7 COLD 6100L

110 95 0.26 108 P2 TWD 10 AV2 +0.00 TEN TEC 13 COLD 61001.0.29 101 P2 TWD 11 AV3 +0.00 TEE TEC 13 COLD 610UL0.24 117 P2 TWD 9 AV5 +0.00 TEN TEC 13 COLD 610UL

110 97 0.17 117 P2 TWD 7 AV7 +0.00 TEN TEC 13 COLD 610OL110 99 0.45 118 P2 TWD 15 AVS +0.00 TEN TEC 17 COLD 610UL110 101 0.23 121 P2 TWD 9 AV2 +0.02 TEN TEC 17 COLD 610UL

0.25 87 P2 TWD 10 AV3 +0.09 TEN TEC 17 COLD 610UL0.17 93 P2 TWD 7 AVI -0.04 TEE TEC 17 COLD 610UL0.16 100 P2 TWD 7 AVS. +0.09 TEN TEC 17 COLD 610UL

110 103 0.13 117 P2 TWD 6 AV2 +0.09 TEN TEC 19 COLD 610UL111 74 0.24 116 P2 TWD 11 AV3 +0.00 TEN TEC 4 COLD 610UL111 76 0.18 98 P2 TWD 9 AV2 +0.02 TEN TEC 4 COLD 61ULI11 84 0.51 120 P2 TWD 17 AV3 +0.00 TEN TEC 1 COLD 610UL

0.45 122 P2 TWD 16 AV4 +0.00 TEN TEC 1 COLD 610UL0.40 127 P2 TWD 15 AV5 +0.00 TEN TEC 1 COLD 610UL0.40 128 P2 TWD 14 AVG +0.00 TEN TEC 1 COLD 610UL0.33 123 P2 TWD 13 AV7 +0.00 TEN TEC 1 COLD 61OUL

111 86 0.29 110 P2 TWD 10 AV2 +0.07 TEN TEC 5 COLD 61001.0.57 118 P2 TWD 17 AV4 +0.09 TEN TEC 5 COLD 610UL0.22 94 P2 TWD 8 AVS +0.13 TEN TEC 5 COLD 610UL0.54 111 P2 TWD 17 AVG +0.07 TEN TEC 5 COLD 610UL0.52 112 P2 TWD 16 AV7 +0.04 TEN TEC 5 COLD 610UL0.38 97 P2 TWD 13 AV8 +0.07 TEH TEC 5 COLD 610UL

Il 88 0.23 133 P2 TWD 9 AV6 +0.11 TEN TEC 8 COLD 610UL0.23 140 P2 TWD 9 AV3 +0.04 TEN TEC 8 COLD 610UL

i1 90 0.15 125 P2 TWD 6 AV3 -0.20 TEN TEC 7 COLD 610UL0.28 123 P2 TWD 10 AV5 +0.09 TEN TEC 7 COLD 610UL0.23 112 P2 TWD 9 AV6 +0.09 TEN TEC 7 COLD 610UL

11 92 0.24 134 P2 TWD 10 AV2 +0.07 TEN TEC 8 COLD 610UL0.12 136 P2 TWD 5 AV6 +0.15 TEN TEC 8 COLD 610UL0.15 138 P2 TWD 7 AV7 +0.04 TEN TEC 8 COLD 610UL

Ill 94 0.13 120 P2 TWD 6 AV3 +0.07 TEN TEC 14 COLD 610UL0.17 120 P2 TWD 7 AV4 +0.02 TEN TEC 14 COLD 610UL0.43 11 P2 TWD 15 AV5 +0.09 TEH TEC 14 COLD 610UL0.16 123 P2 TED 7 AV6 +0.09 TEN TEC 14 COLD 610UL

Page 105: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure I

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 30 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

112 96 0.11

0.210.190.550.14

ill 98 0.200.20

111 102 0.14112 73 0.38

0.210.33

112 83 0.190.190.19

112 85 0.390.200.190.300.130.24

112 87 0.150.270.170.16

112 89 0.210.190.23

112 91 0.180.150.260.250.170.20

112 93 0.21112 95 0.15

0.43112 97 0.21

0.350.30

112 99 0.28112 101 0.17

0.300.43

113 84 0.250.260.440.510.420.15

113 86 0.170.200.250.170.610.560.39

113 88 0.140.170.330.450.37

DEG CHN

126 P2115 P2125 P2113 P2138 P2129 P2121 P2135 P2121 P281 P291 P2105 P266 P261 P2120 P2106 P2112 P2126 P2109 P2121 P2110 P2121 P2115 P290 P2132 P2135 P2135 P2135 P2136 P2122 P2137 P2140 P2140 P2133 P2119 P2123 P2119 P2115 P2110 P2126 P2118 P2122 P2118 P299 P2113 P2120 P2117 P2117 P2100 P2123 P289 P294 P2108 P2117 P2115 P2117 P277 P2112 P2106 P2123 P2120 P2

IND %TW LOCATION EXT EXT UTIL 1 OTIL 2

TWD 5 AVI +0.07 TEN TECTWD 8 AV2 +0.02 TEN TECTWD 8 AV3 +0.02 TEH TECTWD 18 AV4 +0.00 TEH TECTWD 6 AV7 -0.02 TEN TECTWD 8 AV2 +0.00 TEN TECTWD 8 AV3 +0.00 TEN TECTWD 6 AV3 -0.04 TEN TECTWD 15 AVI +0.00 TEN TECTWD 10 AV2 +0.00 TEN TECTWD 14 AV3 +0.00 TER TECTWD 8 AV2 +0.09 TEN TECTWDN 8 AV6 +0.00 TEN TECTWD 8 AV7 +0.00 TEN TECTWD 15 AVI +0.00 TEN TECTWD 9 AV3 +0.07 TEH TECTWD 9 AV4 +0.02 TEH TECTWD 12 AVS +0.04 TEN TECTWD 6 AV6 +0.00 TEN TECTWD 11 AV7 +0.04 TEH TECTWD 6 AV3 +0.00 TEE TECTWD 10 AV5 +0.00 TEN TECTWD 7 AV6 +0.22 TEN TECTWD 7 AV7 +0.00 TEN TECTWD 9 AV2 +0.09 TEN TECTWDN 8 AV6 +0.00 TEH TECTWD 9 AV7 +0.00 TEH TECTWDN 8 AVI +0.00 TEN TECTWD 6 AV2 +0.00 TEH TECTWD 10 AV3 +0.09 TEN TECTWD 10 AV4 +0.02 TEN TECTWD 7 AV5 +0.07 TEN TECTWD 9 AV7 +0.04 TEH TECTWD 9 AV2 +0.04 TEH TECTWD 6 AV2 +0.00 TEN TECTWD 15 AV3 +0.04 TEN TECTWD 9 AV3 +0.09 TEN TECTWD 13 AV4 +0.04 TEN TECTWD 11 AV5 +0.02 TEN TECTWD 11 AV3 +0.00 TEN TECTWD 7 AV2 +0.00 TEH TECTWD 11 AV3 +0.00 TEN TECTWD 15 AV4 +0.00 TEN TECTWD 11 AV2 +0.02 TEN TECTWD 11 AV4 +0.00 TEN TECTWD 17 AV5 +0.00 TEN TECTWD 18 AVG +0.00 TER TECTWD 16 AV7 +0.04 TEN TECTWD 7 AVa +0.00 TEN TECTWD 7 AVI +0.00 TEN TECTWD 8 AV2 +0.00 TEN TECTWD 9 AV4 +0.00 TEN TECTWD 7 AV5 +0.00 TEN TECTWD 19 AV6 +0.00 TEN TECTWD 17 AV7 +0.00 TEN TECTN] 14 AV8 +0.00 TEE TECTN] 6 AV2 -0.15 TEN TECTWD 7 AV3 +0.07 TEN TECTN] 12 AV4 +0.07 TEN TECTWD 15 AV5 +0.07 TEH TECTWD 13 AV6 +0.07 TER TEC

CAL #

141414141418181944422222222266668888888888141414141418181818222222666666

677777

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL610UL610UL610UL610UL6100L610UL3610UL610UL610UL610UL61001.6101L1

610131.610131.61001.610131610U1.61013161001.61001.61013161001.61001.61001.610UL161001.61001.61001.61001.61001.61001.61001.61001.

61001.61001.61001.61001.61001.61001.61001.61001.61001.61001.61001.61001.61001.61001.

61001.61013161001.61001.61001.61001.61001.610UL1610UL610UL

610UL

Page 106: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 31 of 40

SG 28 Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

113 90 0.160.280.270.30

113 92 0.160.130.14

113 94 0.370.400.21

113 96 0.270.390.370.17

113 98 0.18113 100 0.21114 67 0.13114 75 0.22

0.230.20

114 83 0.270.580.550.17

114 85 0.370.580.440.230.42

114 87 0.360.350.540.380.590.430.43

114 89 0.200.300.150.120.270.32

114 91 0.290.200.160.21

114 93 0.160.14

114 95 0.150.260.310.38

114 97 0.19114 99 0.40

0.18114 101 0.27

0.27115 72 0.13

0.17

DEG

135115128122127I09210710190971131021031061101il11511212412212812312212712612912612683941059310596921281087999118

113118131143139110

8857109114117108117119ill10586128

CHN

P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2

IND %TW LOCATION

TWO 6 AV3 -0.11TWD 10 AV5 +0.09TWD 10 AVG +0.09TWD 11 AV7 +0.04TWD 6 AV5 +0.00TWD 5 AV6 +0.15TWD 6 AV7 +0.22TWD 13 AV3 +0.00TWD 14 AV4 +0.00TWD 8 AV5 +0.00TWD 10 AV2 +0.00TWD 13 AV3 +0.00TWD 13 AV4 +0.00TWD 7 AV6 +0.00TWD 7 AV3 +0.00TWD 8 AV2 +0.07TWD 5 AVG +0.00TWD 9 AVI +0.04TWD 10 AV2 +0.02TWD 8 AV3 +0.00TWD 11 AV4 -0.09TWD 19 AV5 +0.07TWD 18 AV6 +0.09TWD 7 AV7 +0.07TWD 14 AVI +0.00TWD 19 AV2 +0.07TWD 16 AV4 +0.07TWD 10 AV5 +0.07TWD 15 AV7 +0.04TWD 12 AVI -0.02TWD 12 AV2 +0.00TWD 17 AV3 +0.07TWD 13 AV4 +0.02TWD 18 AV5 +0.07TWD 14 AVG +0.18TWD 14 AV7 +0.02TWD 8 AVI +0.07TWD 11 AV2 +0.00TWD 6 AV4 -0.27TWD 5 AVS +0.18TWD 10 AVG +0.00TWD 11 AV7 +0.00TWO 11 AV3 +0.04TWD 8 AV4 +0.00TWD 6 AVG +0.18TWO B AV7 +0.18TWO 6 AV2 +0.00TWD 6 AV3 +0.00TWD 6 AV2 +0.00TWD 10 AV3 +0.00TWD 11 AV4 +0.00TWD 13 AV5 +0.00TWD 7 AV3 +0.00TWO 14 AV3 +0.02TWD 7 AV2 +0.02TWO 10 AV2 +0.07TWD 10 AV3 +0.07TWD 5 AV2 -0.07TWD 7 AVI +0.00

EXT EXT UTIL 1 UTIL 2 CAL #

TEH TEC 7TEH TEC 7TEH TEC 7TEH TEC 7TEH TEC 7TEH TEC 7TEH TEC 7TEH TEC 13TEH TEC 13TEH TEC 13TEH TEC 13TEH TEC 13TEH TEC 13TEH TEC 13TEH TEC 17TEE TEC 17TEH TEC 9TEH TEC 3TEH TEC 3TEH TEC 3TEH TEC 1TEH TEC 1TEE TEC 1TEH TEC 1TEH TEC 1TEH TEC 1TEH TEC 1TEH TEC 1TEE TEC 1TEH TEC 5TEH TEC 5TEH TEC 5TEH TEC 5TEH TEC 5TEH TEC 5TEH TEC 5TEH TEC 7TEH TEC 7TEH TEC 7TEH TEC 7TEH TEC 7TEH TEC 7TEH TEC 7TEH TEC 7TEH TEC 7TEH TEC 7TEH TEC 7TEH TEC 7TEH TEC 13TEH TEC 13TEH TEC 13TEH TEC 13TEH TEC 13TEH TEC 17TEH TEC 17TEH TEC 17TEH TEC 17TEH TEC 9TEH TEC 9

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610L610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61013L610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

Page 107: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2 PSL-ENG-SESJ-09-047, Rev. 0Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1 SG 2B, Page 32 of 40

SG 28 Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL 4 LEG PROBE

115 84 0.47 115 P2 TWD 16 AVI +0.00 TEH TEC 1 COLD 610UL0.27 132 P2 TWD 11 AV2 +0.00 TEH TEC 1 COLD 610UL0.41 117 P2 TWD 15 AV3 +0.00 TEH TEC 1 COLD 610UL0.22 127 P2 TWD 9 AV4 +0.00 TEH TEC 1 COLD 610UL0.20 134 P2 TWD 8 AV5 +0.00 TEH TEC 1 COLD 610UL0.19 124 P2 TWD 8 AVG +0.00 TEH TEC 1 COLD 61UL0.60 129 P2 TWD'I9 AV7 +0.00 TEH TEC 1 COLD 610UL0.24 120 P2 TWD 10 AV8 +0.00 TEH TEC 1 COLD 610UL

115 86 0.27 87 P2 TWD 10 AVI +0.04 TEH TEC 5 COLD 610UL0.44 98 P2 TWD 14 AV2 +0.07 TEH TEC 5 COLD 610UL0.58 108 P2 TWD 18 AV3 +0.09 TEH TEC 5 COLD 610UL0.56 108 P2 TWD 17 AV4 +0.07 TEH TEC 5 COLD 61OUL0.31 92 P2 TWD 11 AV5 +0.07 TEH TEC 5 COLD 6100UL0.60 106 P2 TWD 18 AV7 -0.07 TEH TEC 5 COLD 610UL0.41 107 P2 TWD 14 AV8 +0.07 TEH TEC 5 COLD 610UL

115 88 0.13 96 P2 TWD 5 AV2 +0.26 TEH TEC 7 COLD 610UL0.17 109 P2 TWD 7 AV3 +0.07 TEH TEC 7 COLD 610UL0.27 116 P2 TWD 10 AVG +0.09 TEH TEC 7 COLD 61UL0.27 115 P2 TWD 10 AV7 +0.04 TEH TEC 7 COLD 610UL0.24 116 P2 TED 9 AV8 +0.09 TEH TEC 7 COLD 61OUL

115 90 0.13 137 P2 TED 6 AV2 +0.00 TEH TEC 8 COLD 610UL0.13 128 P2 TED 6 AV3 +0.02 TEH TEC a COLD 610UL0.29 131 P2 TED 11 AV5 +0.07 TEH TEC 8 COLD 6100L0.30 132 P2 TWD 11 AVG +0.13 TEH TEC 8 COLD 61OUL0.21 136 P2 TWD 9 AV7 +0.07 TEH TEC 8 COLD 61001.

115 92 0.19 129 P2 TED 8 AV2 +0.02 TEH TEC 8 COLD 610UL0.16 134 P2 TED 7 AV7 +0.11 TEH TEC 8 COLD 610UL.

115 94 0.17 133 P2 TWD 7 AV3 +0.02 TEH TEC 14 COLD 61001.115 98 0.11 144 P2 TWD 5 AVI +0.00 TEH TEC 18 COLD 610UL

0.20 140 P2 TWD 8 AV2 +0.00 TEH TEC 18 COLD 61OUL0.26 125 P2 TWD 10 AV3 +0.00 TEH TEC 18 COLD 610UL0.16 92 P2 TWD 7 AV5 +0.00 TEH TEC 18 COLD 610UL

116 83 0.20 101 P2 TWD 9 AV2 -0.02 TEH TEC 2 COLD 610UL0.28 97 P2 TWD 11 AV3 +0.00 TEH TEC 2 COLD 61UL0.41 105 P2 TWD 15 AV4 +0.00 TEH TEC 2 COLD 610UL0.20 81 P2 TWD 9 AVG +0.00 TEH TEC 2 COLD 610UL

116 85 0.45 125 P2 TWD 17 AVI -0.02 TEH TEC 2 COLD 61UL0.32 112 P2 TWD 13 AV7 +0.02 TEH TEC 2 COLD 61OUL0.24 110 P2 TWD 10 AV8 +0.07 TEH TEC 2 COLD 610UL

116 87 0+.21 126 P2 TWD 8 AV2 +0.00 TEH TEC 6 COLD 61OUL0.23 104 P2 TWD 9 AV3 +0.00 TEH TEC 6 COLD 61UL0.19 90 P2 TWD 8 AV4 +0.00 TEH TEC 6 COLD G6OUL0.47 116 P2 TWD 16 AVS +0.00 TEH TEC 6 COLD G1OUL0.52 112 P2 TWD 17 AVG +0.00 TEH TEC 6 COLD 61OUL0.66 114 P2 TWD 19 AV7 +0.00 TEH TEC 6 COLD 61OUL0.27 103 P2 TED 10 AV8 +0.00 TEH TEC 6 COLD 61OUL

116 89 0.18 131 P2 TED 8 AVG +0.00 TEH TEC 8 COLD 6100L116 91 0.17 123 P2 TED 7 AV3 +0.11 TEH TEC 8 COLD 6100.L

0.16 129 P2 TED 7 AVS +0.07 TEH TEC 8 COLD 61OUL0.16 133 P2 TED 7 AVG +0.07 TEH TEC 8 COLD 610UL0.10 128 P2 TWD 5 AV7 +0.04 TEH TEC LAR 8 COLD 61001L

116 97 0.15 102 P2 TD 6 AV2 +0.04 TEH TEC 14 COLD 610UL117 84 0.43 123 P2 TED 15 AV2 +0.07 TEH TEC 1 COLD 6101.L

0.42 119 P2 TWD 15 AV5 +0.00 TEH TEC 1 COLD 61OUL0.30 134 P2 TWD 12 AVG +0.00 TEH TEC 1 COLD 610UL0.34 124 P2 TWD 13 AV7 +0.00 TEH TEC 1 COLD 610UL

117 86 0.18 91 P2 TWD 7 AV2 -0.09 TEH TEC 5 COLD 610UL0.37 99 P2 TWD 13 AV4 +0.02 TEH TEC 5 COLD 610UL0.43 106 P2 TWD 14 AVG -0.07 TEH TEC 5 COLD 610UL0.46 113 P2 TWD 15 AV7 -0.02 TEH TEC 5 COLD 610UL0.40 109 P2 TWD 14 AV8 +0.13 TEH TEC 5 COLD 610UL

Page 108: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 33 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS DEG CHN IND %TW LOCATION

117 88 0.21 126 P2 TWD 9 AV2 +0.000.15 128 P2 TED 7 AV3 +0.00

0.19 133 P2 TWD 8 AV6 +0.00117 90 0.38 120 P2 TWD 13 AV5 +0.07

0.35 118 P2 TWD 12 AV6 +0.000.25 121 P2 TWD 10 AV7 +0.000.18 118 P2 TWD 7 AV8 +0.00

117 92 0.26 126 P2 TWD 10 AV2 +0.070.20 108 P2 TWD 8 AV3 +0.000.20 127 P2 TWD 8 AV5 +0.000.13 61 P2 TWD 5 AV6 +0.290.13 86 P2 TWD 5 AV7 +0.29

117 94 0.19 86 P2 TWD 7 AV2 +0.00117 100 0.22 118 P2 TWD 9 AV2 +0.00118 83 0.19 120 P2 TWD 8 AV4 -0.02

0.52 127 P2 TWD 17 AV6 +0.000.26 128 P2 TWD 10 AV7 +0.00

118 85 0.40 117 P2 TWD 15 AV2 +0.110.37 127 P2 TWD 14 AV3 +0.070.34 127 P2 TWD 13 AV4 +0.070.52 118 P2 TWD 17 AV5 +0.000.60 116 P2 TWD 19 AV7 +0.04

118 87 0.33 104 P2 TWD 12 AV2 -0.020.17 77 P2 TWD 7 AV3 +0.090.47 94 P2 TWD 15 AV4 -0.020.42 113 P2 TWD 14 AV5 +0.070.19 99 P2 TWD 7 AV7 +0.110.22 82 P2 TWD 8 AV8 +0.04

118 89 0.17 111 P2 TWD 7 AV2 +0.070.33 123 P2 TWD 12 AV5 +0.09

118 91 0.10 85 P2 TWD 4 AV4 -0.130.21 121 P2 TWD 8 AV5 +0.110.31 121 P2 TWD 11 AV6 +0.040.27 118 P2 TWD 10 AV7 -0.150.15 139 P2 TWD 6 AV8 +0.11

118 93 0.17 126 P2 TWD 7 AVI +0.000.29 115 P2 TWD 11 AV2 +0.00

0.39 113 P2 TWD 13 AV6 +0.07118 95 0.22 99 P2 TWD 9 AV2 +0.00

0.36 117 P2 TED 13 AV4 +0.00118 97 0.17 111 P2 TWD 7 AV5 +0.00119 82 0.24 131 P2 TWD 10 AV5 +0.16119 84 0.17 92 P2 TWD 8 AVI +0.00

0.37 117 P2 TWD 15 AV2 +0.020.i9 117 P2 TWD 8 AV6 +0.02

119 86 0.38 120 P2 TWD 13 AVI +0.000.45 116 P2 TWD 15 AV2 +0.000.58 111 P2 TWD 18 AV4 +0.000.24 98 P2 TWD 9 AV6 +0.000.37 123 P2 TWD 13 AV7 +0.000.17 81 P2 TWD 7 AV8 +0.00

119 88 0.21 94 P2 TWD 8 AV2 +0.310.66 118 P2 TWD 19 AV5 +0.000.33 113 P2 TWD 12 AVE +0.090.20 91 P2 TWD 8 AV3 -0.04

119 90 0.12 133 P2 TWD 5 AVI +0.020.13 120 P2 TED 6 AV3 -0.040.21 138 P2 TWD 9 AV5 +0.040.25 132 P2 TWD 10 AVG +0.040.20 127 P2 TWD 8 AV7 +0.07

119 92 0.19 135 P2 TWD 8 AV5 +0.020.13 90 P2 TWD 6 AV7 +0.09

EXT EXT UTIL 1 UTIL 2

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

CAL #

8

887777777771317111111115

55555777

77.77777131313122266666677778

88888

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL610UL610UL61OUL610UL61OUL610UL6O1UL610UL610UL61OUL610UL610UL610UL61OUL610UL61OUL610UL610UL610UL610UL61001.610UL610UL610UL6100L610UL61001L610UL610UL610UL610UL610UL61OUL610UL610UL610UL610UL61001.610UL610UL610UL610UL610UL610UL610UL610UL610UL61001.610UL610UL610UL610UL61001.610UL610UL610UL610UL610UL610UL

Page 109: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 34 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

119 94 0.14120 83- 0.19

0.240.17

120 85 0.130.390.420.24

120 87 0.260.400.380.28

120 89 0.170.170.15

120 91 0.330.180.210.260.19

120 93 0.15120 97 0.12121 82 0.22

0.20121 84 0.29

0.19121 86 0.24

0.680:50

121 88 0.150.260.350.230.14

121 90 0.360.230.330.410.25

121 92 0.140.210.34

121 94 0.220.21

122 83 0.280.450.540.27

122 85 0.400.470.190.390.43

122 87 0.300.380.490.630.400.200.21

DEG

120119108738611612112210611611010512512013712512812612512912911286110126126731081131391321231181471281191261281041401161051081011261201261271251251231281339810210811710876105

CHN

P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2

IND %TW LOCATION

TWD 6 AV2 +0.00TWD 9 AV3 +0.00TWD 10 AV4 +0.02TWD 8 AVE +0.00TWD 6 AV2 +0.02TWD 15 AV4 +0.02TWD 16 AV5 -0.02TWD 11 AV8 +0.11TWD 10 AV4 +0.00TWD 14 AV5 +0.00TWD 13 AVE +0.00TWD 11 AV7 +0.00TWD 7 AVG +0.00TWD 7 AV7 +0.00TWD 7 AV8 -0.04TWD 12 AV2 +0.02TWD 8 AV5 +0.13TWD 9 AV6 +0.00TWD 10 AV7 +0.02TWD 8 AV8 +0.04TWD 7 AV2 +0.00TWD 5 AV3 +0.07TWD 9 AV5 +0.00TWD 9 AV6 +0.00TWD 11 AV6 +0.00TWD 8 AV7 +0.00TWD 9 AV2 +0.02TWD 19 AV5 +0.02TWD 16 AV7 +0.00TWD 7 AV2 +0.02TWD 10 AV5 +0.00TWD 13 AVE +0.00TWD 9 AV7 +0.00TWD 6 AV8 +0.00TWD 13 AV4 +0.00TWD 9 AV5 -0.02TWD 12 AVE +0.20TWD 14 AV7 +0.00TWD 9 AV8 +0.00TWD 6 AV2 +0.18TWD 8 AV3 +0.00TWD 12 AV7 +0.13TWD 9 AV3 +0.00TWD 8 AV4 +0.00TWD 11 AV2 -0.02TWD 16 AV3 +0.04TWD 18 AV4 +0.02TWD 11 AV5 +0.02TWD 15 AV2 +0.11TWD 16 AV3 +0.07TWD 8 AV4 +0.07TWD 14 AVE +0.07TWD 15 AV7 +0.04TWD 11 AV2 +0.09TWD 13 AV3 +0.09TWD 16 AV4 +0.13TWD 19 AV5 +0.16TWD 13 AVE +0.02TWD 8 AV7 +0.02TWD 8 AV8 -0.04

EXT EXT UTIL 1 UTIL 2

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

CAL #

1422222226666

888888888

1422115558888877777777

13131111111115555555

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

010UL61OUL610UL610UL61OUL610UL610UL610ULE01UL610UL610UL61OUL610UL610UL610UL61oUL6100.L61OUL61OUL610UL61EUL61oUL61oUL610UL610UL610ULEloUL610UL61OUL61oUL61oUL61OUL61oUL61OUL61OUL610Lt610UL6ioUL61oUL610UL61OUL610UL610UL610Lt610UL610LT610UL610UL61oUL

Page 110: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 35 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

122 89 0.180.260.170.300.16

122 91 0.170.230.360.180.150.15

122 93 0.170.28

122 95 0.240.16

122 99 0.190.17

123 84 0.320.56

123 86 0.140.450.140.47

123 88 0.270.170.13'

123 90 0.160.560.510.120.23

123 92 0.160.16

123 94 0.160.130.29

123 98 0.120.18

124 83 0.210;280.290.21

124 8S 0.240.370.240.450.27

124 87 0.230.170.240.340.15

124 89 0.30124 91 0.29

0.300.18

124 93 0.150.15

125 82 0.160.13

DEG CHN IND %TW LOCATION EXT EXT UTIL 1 UTIL 2 CAL # LEG

99 P2113 P275 P2119 P277 P2129 P286 P2124 P2126 P2102 P2115 P2107 P2116 P2103 P2137 P2114 P2180 P2120 P2112 P2108 P2116 P270 P2122 P2121 P2101 P262 P2130 P2124 P2123 P2105 P2140 P2132 P277 P2144 P2107 P2107 P2134 P2146 P2112 P2124 P2125 P297 P2103 P2119 P2115 P2127 P2124 P2116 P2112 P2123 P2125 P211 P2136 P2131 P2131 P2117 P2138 P2140 P282 P2111 P2

TWD 7TWD 10TWD 7TWD 11TWD 6TWD 7TWD 9TWD 13TWD 7TWD 6TWD 6TWD 7TWD 10TWD 9TWD 6TWD 8TWD 7TWD 13TWD 19TWD 6TWD 15TWD 6TWD 16TWD 10TWD 7TWD 5TWD 7TWD 18TWD 17TWD 5TWD 9TWD 7TWD 7TWD 7TWD 6TWD 11TWD 5TWD 8TWD 9TWD 12TWD 12TWD 9TWD 10TWD 15TWD 11

TWD 17TWD 12TWD 9TWD 7TWD 9TWD 12TWD 6TWD 12TWD 11TWD 11TWD 8TWD 6TWD 7TWD 8TWD 6

AV3AV4AV6AV5AV2AVIAV2AVS

AV6AV7AV8AV7AV2AV2AV3AV2AV7AV6AV7AV2AV3AV4AV5AV7AV8AV2Av3AV4AV5AV6AV7AV2

AV7AV2AV3AV4AV2

AV3AV3AV4AV5

AVGAV2AV3AV4AVSAV8AV1AV2AV4AV5AV7AV8

AV6AV7AV5AV2AV4AV4AV7

+0.11+0.13+0.07+0.07+0.04+0.00+0.00+0.00+0.00-0.16+0.00+0.22+0.04+0.00+0.00+0.00+0.29-0.02+0.07+0.00+0.00+0.00+0.00+0.00+0.07-0.18+0.02+0.09+0.07+0.02+0.11+0.02+0.24-0.02+0.18+0.09+0.00+0.00+0.02-0.02+0.02+0.02+0.02+0.04-0.02+0.02+0.09+0.00+0.00+0.00+0.00+0.00+0.00+0.13+0.07+0.07+0.09+0.13-0.02-0.02

TEH TECTEE TECTEE TECTEE TECTEE TECTEN TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEN TECTEE TECTEH TECTEN TECTEE TECTEN TECTEN TECTEN TECTEN TECTEE TECTEE TECTEE TECTEE TECTEN TECTEE TECTEE TECTEE TECTEE TECTEH TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEE TECTEN TECTEE TECTEN TECTEN TECTEH TECTEE TECTEE TECTEE TECTEN TECTEE TECTEE TECTEE TECTEE TECTEN TECTEN TECTEE TECTEE TECTEN TEC

LAR

LAR

LAR

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

61oUL6ioUL610SUL61oUL61oUL610UL61oUL61oUL61oUL610UL610UL610UL61OUL61OUL6ioUL610ULo61OUL61oUL61OUL61oUL

0ioUL

61oUL61siLt61oUL610UL61oUL610UL61oUL610UL61oULsioUL610UL610UL610UL610UL61oUL61oUL610UL610UL61oUL61OUL61sUL610UL610UL61SUL610UL61oUL61oUL61oUL61oUL61oUL610UL61oUL610lot

6ioUL61ouL61SUL610UL610UL610Lt

Page 111: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 36 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

125 84 0.230.180.23

125 86 0.420.420.460.19

125 88 0.130.160.14

125 90 0.080.130.260.35

125 92 0.10125 94 0.16125 96 0.20126 83 0.22126 85 0.39

0.350.26

126 87 0.180.180.200.40

126 89 0.150.27

126 91 0.15126 93 0.26

0.14126 95 0.17127 68 0.17

0.18127 74 0.19127 84 0.36

0.320.280.280.55

127 86 0.290.220.22

127 88 0.170.13

127 90 0.250.240.24

0.18127 92 0.13

0.11127 102 0.12128 67 0.12128 83 0.15128 85 0.22

0.340.510.13

128 87 0.15128 91 0.18

0.180.120.170.18

DEG CHN

114 P2119 P2124 P2105 P2102 P2118 P280 P2143 P2134 P2144 P2103 P274 P2121 P2118 P2108 P297 P2I11 P2124 P2121 P2129 P2136 P278 P297 P2105 P2104 P2114 P2106 P288 P297 P2118 P273 P2132 P290 P2113 P298 P294 P283 P2121 P2117 P2122 P2103 P2107 P298 P2121 P2131 P2134 P2121 P2128 P2132 P2108 P2123 P263 P2104 P2102 P2113 P2117 P2117 P287 P2125 P2133 P2129 P2139 P2146 P2

IND %TW

TWD 10

TWD 8TWD 10TWD 14TED 14TWD 15TED 7TWD 6TWD 7TWD 6TED 3TWD 5TWD 10

TWD 12TWD 4TWD 6TWD 8TWD 9TWD 14TED 13TWD 10TWD 7TWD 7TWD 8TED 14TWD 6TWD 10TWD 6TWD 10TWD 6TWD 7TED 7TWD 7TWD 9TWD 14TWD 13TED 12TWD 11TED 19TWD 11TWD 8TWD 9TED 7TWD 5TWD 10TWD 10TWD 10TWD 8TWD 6TWD 5TWD 5TWD 6TWD 7TWD 10TED 14TWD 18TWD 6TWD 6TWD 8TWD 8TWD 5TWD 7TWD 8

LOCATION EXT EXT UTIL 1 UTIL 2AV3 , +0.00 TEH TE-C

AV4 +0.00 TEH TECAV5 +0.00 TEH TEC

AV4 +0.07 TEH TECAV5 -0.07 TEH TECAVG +0.13 TEH TECAV8 +0.11 TEH TECAV2 +0.13 TEH TECAVG +0.00 TEH TEC

AV8 40.16 TEH TECAVI +0.29 TEH TECAV2 -0.13 TEH TECAV5 +0.00 TEH TECAVG +0.00 TEH TECAV7 +0.24 TEH TECAV2 +0.00 TEH TECAV1 +0.00 TEH TECAV5 +0.00 TEH TECAV4 +0.04 TEH TECAV7 +0.07 TEH TECAV3 -0.11 TEH TECAV2 +0.09 TEH TECAV3 +0.04 TEH TECAV5 +0.16 TEH TECAV7 +0.00 TEH TECAV5 +0.24 TEH TECAVG +0.00 TEH TECAV7 -0.13 TEH TECAV2 +0.02 TEH TECAVG +0.24 TEH TECAV5 +0.00 TEH TECAV3 +0.07 TEH TECAV2 +0.00 TEH TECAV3 +0.00 TEH TECAV2 +0.09 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAVE +0.00 TEH TECAV6 +0.00 TEH TECAV3 +0.00 TEH TECAV4 +0.00 TEH TECAVG +0.00 TEH TECAV2 -0.13 TEH TECAVG +0.20 TEH TECAVI +0.04 TEH TECAV4 +0.11 TEH TECAV7 +0.11 TEH TECAV8 +0.07 TEH TECAV3 +0.04 TEH TECAV7 -0.02 TEH TECAV2 -0.02 TEH TECAVG -0.15 TEH TECAV3 +0.00 TEH TECAV2 +0.02 TEH TECAV3 +0.02 TEH TECAV5 +0.00 TEH TECAVG -0.02 TEH TECAV5 +0.00 TEH TECAV2 -0.04 TEH TECAV3 +0.00 TEH TECAVE +0.07 TEH TECAVG +0.09 TEH TECAV7 +0.04 TEH TEC

CAL # LEG

1 COLD1 COLD1 COLD5 COLD5 COLD5 COLD5 COLD8 COLD8 COLD8 COLD7 COLD7 COLD7 COLD7 COLD7 COLD13 COLD13 COLD1 COLD1 COLD1 COLD1 COLD5 COLD5 COLD5 COLD5 COLD7 COLD7 COLD7 COLD7 COLD7 COLD13 COLD9 COLD9 COLD4 COLD2 COLD2 COLD2 COLD2 COLD2 COLD6 COLD6 COLD6 COLD7 COLD7 COLD8 COLD8 COLD8 COLD8 COLD8 COLD8 COLD19 COLD10 COLD2 COLD2 COLD2 COLD2 COLD2 COLD6 COLD8 COLD8 COLD8 COLD8 COLD8 COLD

PROBE

61OLL610UL061OUL61OUL610ULT610UL610UL61OUL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610ULL610UL610UL610UL610UL610UL610UL61001.610UL6100UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

Page 112: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 37 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

128 97 0.16128 103 0.19128 117 0.13

0.12129 68 0.19129 84 0.44

0.260.330.23

129 86 0.540.270.510.37

129 88 0.140.15

129 90 0.340.550.350.200.33

129 92 0.130.100.080.15

129 94 0.180.210.19

129 102 0.110.170.29

130 85 0.170.560.580.450.30

130 87 0.260.18

130 89 0.230.210.25

130 91 0.'200.24

130 93 0.35130 95 0.19

0.160.15

130 97 0.16130 103 0.16

0.15131 82 0.27131 86 0.19

0.20

0.44

0.420.14

131 88 0.20131 90 0.35

0.130.180.11

DEG CHN

112 P2102 P2112 P298 P255 P2128 P2128 P2131 P2140 P2111 P297 P2110 P291 P2148 P2146 P2121 P2118 P2100 P2126 P2113 P2129 P259 P242 P2128 P2105 P2116 P2100 P2130 P2112 P2117 P2113 P2120 P2124 P2134 P2139 P2104 P253 P2113 P2100 P294 P2103 P2107 P2124 P2129 P2110 P2107 P2106 P2119 P2127 P2100 P2104 P2112 P2118 P2124 P2108 P2112 P2136 P2137 P2128 P2150 P2

IND %TW

TWD 7TW] 8TWD 6TWD 6TWD 9

TED 16TED 10TWD 13TED 10TWD 17TED 10TED 16TWD 13TWD 6TWD 7TED 12TED 17TED 12TWE 8TED 12TWD 5TED 4TED 3TED 6TED 7TED 8TED 7TIED5TWD 7TED 12TWD 7TED 18TED 19TED 16TWD 12TWD 10

TWD 7TWD 9TWD 8TED 10TWD 8TWD 9TWD 12TWD 7TWD 6TWO 6TWD 6TWD 7TWD 6TED 11TWD 8TWD 8TED 15TWD 14TWD 6TWD 8TWD 13TWD 6TWD 8TWD 5

LOCATION

AV2 +0.04AV2 +0.00AV7 -0.13AVS -0.13AV2 +0.00AV3 +0.00AV4 +0.00AV5 +0.00AV7 +0.04AV4 +0.02AVS -0.02AVE +0.02AV7 +0.02AV2 -0.18AV7 +0.00AV3 -0.07AV4 +0.00AVS +0.00AVG +0.13AV7 +0.11AV2 +0.20AV3 -0.09AVE +0.33AV7 -0.11AV2 +0.00AV3 +0.00AV4 +0.00AV2 +0.00AV3 +0.00AV4 +0.00AV2 +0.00AV3 -0.02AV5 +0.04AVE +0.02AV7 +0.11AVE +0.00AV7 +0.04AV2 +0.04AV5 +0,09AV6 +0.11AV2 +0.00AVE +0.09AV2 +0.07AV4 +0.00AVG +0.00AV8 +0.00AV2 +0.00AV2 +0.02AV4, -0.04AV4 +0.33AV2 +0.00AV5 +0.00AV6 +0.00AV7 +0.00AV8 +0.00AVE +0.07AVI -0.02AV2 +0.00AV3 -0.02AV7 +0.13

EXT EXT

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEE TECTEE TECTEH TECTEH TECTEH TECTEH TECTEE TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

UTIL 1 UTIL 2 CAL #

1420282810

I111S5SS

8877777777713

13132020

20111115577777713131313191916666

LAR 678888

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL610UL610UL61001L610UL610UL610UL610UL610UL.610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL6100L.610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL61001L610UL610UL610UL61001.

610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL610UL

Page 113: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 38 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

131 92 0.120.140.150.10

131 94 0.21131 102 0.15131 104 0.13132 67 0.25132 71 0.20132 85 0.17132 87 0.24

0.17132 89 0.26132 91 0.33

0.18132 93 0.15

0.12132 95 0.14132 103 0.17

0.150.320.15

133 68 0.25133 70 0.15133 82 0.15133 86 0.17

0.17133 88 0.20

0.20133 90 0.30

0.260.630.640.360.62

133 92 0.120.24

133 102 0.240.15

134 67 0.380'.270.230.19

134 71 0.25134 73 0.17

0.13134 77 0.14134 79 0.11134 85 0.16

0.130.540.270.210.12

134 87 0.23134 89 0.14

0.250.280.290.190.17

DEG

1511421421301011287510212464122135133138132145149115125105126112971121266265139121116124119110127120129113117132103102ill114125997067561161239810010312175861071019712552

CHN

P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2

IND %TW

TWD 5TWD 6TWD 7TWD 5TWD 9TWD 6TWD 6TWD 11TWD 9TWD 8TWD 9TWD 7TWD 10TWD 13TWD 8TWD 6TWD 5TWD 6TWD 8TWD 7TWD 13TWD 7TWD 11TWD 6TWD 7TWD 7TWD 7TWD 8TWD 9TWD 11TWD 10

TWD 19TWD 19TWD 13TWD 19TWD 5TWD 9TWD 10TWD 7TWD 13TWD 10TWD 9TWD 7TWD 9TWD 7TWD 5TWD 6TWD 5TWD 6TWDl 5TWD 17TWD 10TWD 8TWD 5TWD 5TWD 6TWD 9TWD 10TWD 11TED 7TWD 7

LOCATION

AV3 -0.02AV6 +0.11AV7 +0.07AV8 +0.02AV3 +0.33AV2 -0.07AV3 +0.20AV8 +0.00AV6 +0.00AV3 +0.02AV5 +0.00AV6 +0.00AV4 +0.02AV5 +0.04AV6 +0.09AV4 -0.02AVG +0.02

AV4 -0.09AV2 +0.00AV3 +0.00AV4 +0.00AV7 +0.00AVS +0.00AV6 +0.04AV6 +0.02AVG +0.16AV4 +0.04AV2 +0.00AV5 +0.00AV2 +0.00AV3 -0.04AV4 +0.00AV5 +0.00AV6 +0.00AV8 +0.00AV2 +0.22AV7 +0.02AV2 +0.00AV3 +0.00AV4 -0.28AVG +0.00AV7 +0.00AV3 +0.11AV6 +0.00AV8 +0.07AV7 -0.15AV4 +0.00AV6 +0.00AV8 +0.00AV7 +0.00AV6 +0.00AV5 +0.00AV4 +0.00AVI +0.00AVS +0.00AV7 +0.00AV6 +0.00AVS +0.00AV4 +0.00AV3 +0.00AV2 +0.00

EXT EXT UTIL 1 UTIL 2

TEE TECTEN TECTEN TECTEE TECTEN TECTEE TECTEN TEC LARTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTER TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TEC LARTEN TECTEN TECTEN TECTEN TEC LARTER TECTEN TECTEN TECTEN TECTER TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEE TECTEE TECTEN TECTEN TEC LARTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TECTEN TEC

CAL #

888814191910426688888

142020202010925588777777772020

808080801028080808080808080808080808o80808080

LEG

COLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLDCOLD

PROBE

610UL610UL61OUL610UL610UL610ULT610UL610UL610UL610UL61001.610 LT610UL61001L610UL610TJL610UL610UL610UL610UL610UL610UL610UL6102UL6100L2610UL610UL610UL610UL61OUL610UL61001L610UL610UL610UM610UL610UL610UL610UL6101UL610UL61UOLL6101UL6100UL61001.610UL610UL61001.6iouL610UJL610UL610UL610UL610UL610UL610TUL610UL610UJL610UL610UL61001.

Page 114: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 39 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

134 91 0.370.180.200.23

134 93 0.19134 103 0.32

0.220.140.320.230.130.17

135 76 0.170.12

135 78 0.12135 80 0.14

0.13135 82 0.15

0.260.29

135 84 0.190.250.42

135 90 0.270.460.210.210.190.160.130.29

135 92 0.300.150.14

135 94 0.11

0.18135 96 0.26

0.310.14

136 83 0.290.17

136 85 0.170.530.310.150.360.25

136 87 0.200.160.31

136 89 0.250.280.300.25

136 91 0.290.260.370.560.500.390.19

DEG

12913412113411311211182109997099106123III796210512611511589106111989861'121109981228769102971231231086312581140130118132128129129137130126129131117131136125119121120136

CHN

P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2P2

IND %TW

TWD 12TWD 7TWD 8TWD 8TWD 7TWD 11TWD 8TWD 6T iD 11

TWD 9TWD 5TWD 7TWD 7TWD 5TWD 5TWD 6TWD STWD 6TWD 10TWD 10TWD 7TWD 9TWD 14TWD 10TWD 15TWD 8TWD 8TWD 7TWD 6TWD 5TWD 10TWD 11TWD 6TWD 5TWD STWD 7TWD 9T iD 11

TWD 6TWD 11TWD 7TWD 7TWD 17TWD 11

TWD 6END 13TWD 10TWD 8TWD 6END 11TWD 10TWD 10T iD 11TWD 10TWD 11TWD 10TND 13TWD 18TWD 16TWD 14TWD 8

LOCATION

AV8 +0.11AV7 -0.11AV6 +0.18AV5 +0.13AV3 +0.00AV8 +0.02AV7 +0.04AV6 +0.07AV5 +0.33AV4 -0.24AV3 -0.33AV2 -0.20AV7 +0.09AVG +0.07AV2 +0.00AVG +0.00AV2 +0.09AV7 +0.00AV6 +0.00AV5 +0.00AV6 +0.00AV5 +0.00AV4 +0.00AV8 +0.00AV6 +0.00AV5 +0.00AV4 +0.00AV3 +0.00AV2 +0.00AVI +0.00AV7 +0.04AV7. +0.04AV6 +0.00AV2 +0.07AV6 +0.02AV3 +0.13AV3 +0.04AV2 +0.00AVi +0.00AVG +0.11AV4 -0.07AV8 +0.07AV7 +0.13AV6 +0.07AV5 +0.09AV4 +0.04AV3 +0.13AVG +0.02AV5 +0.00AV4 -0.02AV7 +0.16AVG +0.00AV4 +0.00AV3 +0.00AV7 +0.11AV6 +0.07AV5 +0.09AV4 +0.11AV3 +0.04AV2 +0.02AVI +0.02

EXT EXT

TEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTER TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TECTEH TEC

UTIL 1 UTIL 2 CAL #

102102102102808080808080808080808080808080

808080808080808080808080808080808080808081818181818181818181818181818181818181818181

LEG PROBE

COLD 61OULCOLD 61OULCOLD 61OULCOLD 61OULCOLD 610ULCOLD 610ULCOLD 61OULCOLD 61OULCOLD 610ULCOLD 610ULCOLD 61OULCOLD 61OULCOLD 61OULCOLD 610ULCOLD 610ULCOLD 61OULCOLD 61OULCOLD 61OULCOLD 610ULCOLD 610ULCOLD 61OULCOLD 61OULCOLD 61OULCOLD 610ULCOLD 61OULCOLD 610ULCOLD 6100LCOLD 610ULCOLD 610ULCOLD 61OULCOLD 610ULCOLD 61OULCOLD 61OULCOLD 610ULCOLD 610ULCOLD 610ULCOLD 610ULCOLD 61OULCOLD 610ULCOLD 61OULCOLD 610ULCOLD 61OULCOLD 610ULCOLD 610ULCOLD 61OULCOLD 61OULCOLD 61OULCOLD 610ULCOLD 610ULCOLD 6100LCOLD 61OULCOLD 610ULCOLD 610ULCOLD 61OULCOLD 610ULCOLD 610ULCOLD . 610UL

COLD 61OULCOLD 61OULCOLD 61OULCOLD 610UL

Page 115: St. Lucie, Unit 2 - Refueling Outage SL2-18, Steam ...Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 November 9, 2009 L-2009-254 10 CFR 50.55a 10 CFR 50.36

St. Lucie Unit 2Steam Generator Tube Inspection Report

Attachment 2 to Enclosure 1

PSL-ENG-SESJ-09-047, Rev. 0

SG 2B, Page 40 of 40

SG 2B Wear Indications 1-19% TWD at AVB locations (continued)

ROW COL VOLTS

137 90 0.250.250.160.410.180.480.14

138 85 0.170.270.110.380.150.15

139 92 0.16

DEG CHN

105 P2113 P2123 P2110 P278 P2119 P286 P267 P298 P288 P2108 P275 P292 P2136 P2

IND %TW LOCATION EXT EXT UTIL 1 UTIL 2

TWD 9 AV7 +0.00 TEH TECTWD 9 AVG +0.00 TEH TECTWO 6 AV3 +0.00 TEH TECTWD 14 AV2 +0.00 TEH TECTWD 7 AVi +0.00 TEH TECTWD 15 AV4 +0.15 TEH TECTWD 6 AV8 +0.00 TEH TEC LARTWD 7 AV7 +0.00 TEH TECTWD 10 AV6 +0.00 TEH TECTWD 5 AV5 +0.00 TEH TECTWD 13 AV4 +0.00 TEH TECTWD 6 AV3 +0.00 TEH TECTWD 6 AV2 +0.00 TEH TECTWD 7 AV7 +0.02 TEH TEC

CAL # LEG

80 COLD80 COLD80 COLD80 COLD80 COLD80 COLD80 COLD80 COLD80 COLD80 COLD80 COLD80 COLD80 COLD81 COLD

PROBE

61OUL61OUL61OUL61OUL61OUL61OUL610OUL61OUL61OUL610UL610UL61OUL610UL61OUL

Total Tubes : 815Total Records: 2095