COS STANDARD DESIGN
SSA WAREHOUSE 44220
CLIMATE ZONE 3B - FORT BLISS TX
OCTOBER 2012
100% DESIGN
Fort Worth District
1'-0" 1'-0"
1'-0"
8"
2'-4"
1'-0" 1'-0" 1'-2"
1'-4"
1'-0"
U.S.
AR
MY C
OR
PS O
F E
NGIN
EE
RS
FO
RT W
OR
TH, T
X 7
6102
PN: 00000
CO
S S
TA
ND
AR
D D
ESIG
N
CLIM
AT
E Z
ON
E 3
B – F
T B
LIS
S T
X
SS
A W
AR
EH
OU
SE 4
4220
Fort Worth District
1:1OC
TO
BE
R 2
012
S. SIV
AK
UM
AR
C.
DA
VIS
K.
OLS
ON
SS
A_3
B-S
E610.d
gn
KA
NS
AS CIT
Y,
MO 6
4106
601 E. 12T
H S
TR
EE
T
U.S.
AR
MY C
OR
PS O
F E
NGIN
EE
RS
FO
OTIN
G S
CH
ED
ULE A
ND P
ED
ES
TA
LS
J.
BU
SHIE
819 T
AY
LO
R S
TR
EE
T
SE610
US Army Corps
of Engineers
AP
PR.
DA
TE
DE
SC
RIP
TIO
NS
YM
Desig
ned b
y:
Date:
Dra
wn b
y:
Dra
win
g c
ode:
Plot scale:
Checked b
y:
Sub
mitte
d b
y:
CA
DD File N
am
e:
NUMBER
SHEET
pw:\\NWK-AP-ED-PWINT.nwk.ds.usace.army.mil:PWNWK00\Documents\Military\SWF COS Designs\SSA Warehouse\6.0 Engineering & Design\6.1 CADD Drawings\CAD_BIM Models\_Sheets 3B - FORT BLISS TX\SSA_3B-SE610.dgn
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
10/23/2012 2:10:50 PM
DEAD SNOW WIND
(UNO)PEMB COLUMN
E-1, E-2, E-8, E-9A-3, A-4, A-8, A-9
X-BRACING @
COLATERAL EARTHQUAKE DEAD SNOW WINDCOLLATERAL EARTHQUAKE WIND EARTHQUAKE
VERTICAL LATERAL LONGITUDINAL
GRIDS A & E, 1&11
0 0 5 13
+8
+1 0
+4
+8
+8
0 0
+3
0/-44
-1/-22
0 0
+1/-1
+2/-2 +6
+4
0
+5
+2
0
+9
+5
0
+4
+2
0
-1/-21
-1/-12
-7/+7
+3/-3
+2/-2
+1/-1
0
0
0
0
0
0
LONGITUDINAL LOAD IS THE HORIZONTAL COMPONENT OF THE BRACE LOAD ACTING IN THE DIRECTION OF THE BRACE.
(-) VERTICAL LOAD IS ACTING UPWARD ON FOUNDATION ; (-) LATERAL LOAD IS ACTING INWARD TOWARDS BUILDING.
(+) VERTICAL LOAD IS ACTING DOWNWARD ON FOUNDATION ; (+) LATERAL LOAD IS ACTING OUTWARD AWAY FROM BUILDING.
3.
2.
1.
F1
F2
F3
FOOTING MARKLXW
LENGTH X WIDTH
T
THICKNESS
EACH WAY
EQUALLY SPACED
BOTTOM REINF
EACH WAY
EQUALLY SPACED
TOP REINF
REMARKS
(6) - #5
(4) - #4
(6) - #5
(4) - #4
3.
2.
1.
3.
2.
1.
FOOTINGS FOR ALL PERIMETER COLUMNS SHALL BE CENTERED 1' - 2" INBOARD OF GRIDS A, E, 1, AND 11.
SEE PEDESTAL NOTES FOR DOWELS
REFER TO NOTE V.C.13 ON DRAWING SE001.
FOOTING NOTES:
3.
2.
1.
PEDESTAL NOTES:
GRIDS 1&11, B, C AND D
FOOTING SCHEDULE
GRIDS A & E, 10
GRIDS A & E, 2-9 +8 0/-40 +2/-2 +6 +4 +8 +3 0/-18 +3/-3 0 0
LIVE
ROOF
LIVE
ROOF
+12
+11
+16
+15
-4/+4
6.
5.
4.
3.
2.
1.
ASSUMED LOADING TO FOUNDATIONS FROM PEMB COLUMNS AND X-BRACING (UNFACTORED, KIPS)
+7
+6
-10/+10
LOCATED BELOW THE TOP OF CONCRETE PER NOTE 3.)PEDESTAL DETAIL IS SHOWN LOOKING DOWN ABOVE TOP OF CONCRETE ELEV = 100'-0". TIES ARE SHOWN SOLID FOR CLARITY. (TIES ARE ACTUALLY
ORIENTATION VARIES AND MAY BE MIRRORED, SEE PLAN.
TOP OF COLUMN PEDESTALS ELEV = 98' - 10"
PROVIDE (3) #3 TIES @ 3" O.C. STARTING AT 2" FROM TOP OF PEDESTAL ELEV = 98'-10" AND #3 TIES @ 8" O.C. FOR THE REMAINING HEIGHT, UNO.
#6 VERTICAL BARS SHOWN. PROVIDE 90 DEGREE STANDARD HOOK INTO FOOTING.
REFER TO NOTE V.C.13 ON DRAWING SE001.
ELEV = 98'-10"
T/ CONCRETE
GRID
FO
UN
DA
TIO
N W
ALL
BL
OC
K O
UT I
N C
ON
CR
ET
E
8" x 2'-0" x 1'-2"
DE
EP
SE610
1 PEDESTAL TYPE P1SCALE: 3/4" = 1'-0"
GRID
9'-6" X 9'-6"
5'-0" X 5'-0"
3'-0" X 3'-0"
1'-4"
1'-0"
1'-0"
F4 7'-0" X 7'-0" 1'-4" (8) - #5 (8) - #5
(10) - #5(10) - #5
NOTES:
ELEV = 98'-10"
T/ CONCRETE
ELEV = 100'-0"
T/ CONCRETE
WALL
RETAINING
ELEV = 100'-4"
T/ CONCRETE
SE610
2
SE112
SE111 SCALE: 3/4" = 1'-0"
PEDESTAL TYPE P1A
NOTE: SEE 1/SE610 FOR INFORMATION NOT SHOWN.
SE111
UNO
ELEV = 100'-0"
T/ CONCRETE
3
7
E
US Army Corps
of Engineers
AP
PR.
DA
TE
DE
SC
RIP
TIO
NS
YM
Desig
ned b
y:
Date:
Dra
wn b
y:
Dra
win
g c
ode:
Plot scale:
Checked b
y:
Sub
mitte
d b
y:
CA
DD File N
am
e:
NUMBER
SHEET
pw:\\NWK-AP-ED-PWINT.nwk.ds.usace.army.mil:PWNWK00\Documents\MIL\SWF COS Designs\SSA Warehouse\6.0 Engineering & Design\6.1-NWK\CAD_BIM\_Sheets 3B\SSA_3B-AE110.dgn
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
10/24/2012 10:59:59 AM
257'-4"
79'-4"
0 1648 3216
" = 1'-0"161SCALE:
SITE ORIENTATION
RE: CIVIL FOR
NORTH
PLAN
N
AE110
1
SCALE: 1/16" = 1'-0"
AE110 AE112AE110 AE111
1 1
AE110 AE210
AE110 AE210
AE110 AE210
AE110 AE210
A
B
C
D
AE110 AE310 AE110 AE310 AE110 AE310
AE110 AE310
A B C
A B C
D
D
FLOOR PLAN
STANDARD DESIGN SQUARE FOOTAGE
LOCAL CONDITIONS
DESIGN TO SITE AS REQUIRED FOR
EXTERIOR LOADING DOCK AND RAMP
GENERAL SHEET NOTES
THICKNESS FOR CLIMATE ZONE 3A AND 3B.
2. INSULATED METAL PANEL SHALL BE 2" IN
ROUGH OPENING.
EXTERIOR FACE OF GIRT, OR FROM EDGE OF
1. ALL EXTERIOR DIMENSIONS ARE FROM
3. PEMB EDGE OF FRAMING = 20415 SF
2. 2" PANEL EXTERIOR PANEL = 20528 GSF
1. DESIGN ALLOWS = 20640 GSF
U.S.
AR
MY C
OR
PS O
F E
NGIN
EE
RS
FO
RT W
OR
TH, T
X 7
6102
PN: 00000
CO
S S
TA
ND
AR
D D
ESIG
N
CLIM
AT
E Z
ON
E 3
B – F
T B
LIS
S T
X
SS
A W
AR
EH
OU
SE 4
4220
Fort Worth District
1:1OC
TO
BE
R 2012
M C
OA
TE
S
M M
CC
OLL
UM
J P
ET
RY
SS
A_3
B-A
E110.d
gn
KA
NS
AS CIT
Y,
MO 6
4106
601 E. 12T
H S
TR
EE
T
U.S.
AR
MY C
OR
PS O
F E
NGIN
EE
RS
FL
OO
R P
LA
N
M M
CC
OLL
UM
819 T
AY
LO
R S
TR
EE
T
AE110
US Army Corps
of Engineers
AP
PR.
DA
TE
DE
SC
RIP
TIO
NS
YM
Desig
ned b
y:
Date:
Dra
wn b
y:
Dra
win
g c
ode:
Plot scale:
Checked b
y:
Sub
mitte
d b
y:
CA
DD File N
am
e:
NUMBER
SHEET
pw:\\NWK-AP-ED-PWINT.nwk.ds.usace.army.mil:PWNWK00\Documents\MIL\SWF COS Designs\SSA Warehouse\6.0 Engineering & Design\6.1-NWK\CAD_BIM\_Sheets 3B\SSA_3B-AE120.dgn
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
10/24/2012 11:06:03 AM
258'-0"
80'-0"
4'-0"
101'-0"
0 1648 3216
" = 1'-0"161SCALE:
SITE ORIENTATION
RE: CIVIL FOR
NORTH
PLAN
N
AE120
1
SCALE: 1/16" = 1'-0"
AE120 AE210
CA B C
AE120 AE310
A
AE120 AE310
B
AE120 AE210
A
AE120 AE310
C
AE120 AE210
B
D
AE120 AE210
D
AE120 AE310
D
ROOF PLAN
1/1
2 S
LO
PE
1/1
2 S
LO
PE
AE120 AE121
1
AE120 AE122
1
5. RE: ELECTRICAL FOR LIGHTNING PROTECTION.
PENETRATION LOCATIONS.
4. RE: MECHANICAL & PLUMBING FOR ROOF
BE CONSIDERED IN LIEU OF SKYLIGHTS.
3. OTHER OVERHEAD DAY LIGHTING SYSTEMS MAY
FASCIA.
2. DIMENSIONS PROVIDED ARE FROM EDGE OF
1. CENTER SKYLIGHTS BETWEEN STRUCTURAL BAYS.
GENERAL SHEET NOTES
SEAM METAL ROOF
STEEL STANDING
U.S.
AR
MY C
OR
PS O
F E
NGIN
EE
RS
FO
RT W
OR
TH, T
X 7
6102
PN: 00000
CO
S S
TA
ND
AR
D D
ESIG
N
CLIM
AT
E Z
ON
E 3
B – F
T B
LIS
S T
X
SS
A W
AR
EH
OU
SE 4
4220
Fort Worth District
1:1OC
TO
BE
R 2
012
M C
OA
TE
S
M M
CC
OLL
UM
J P
ET
RY
SS
A_3
B-A
E120.d
gn
KA
NS
AS CIT
Y,
MO 6
4106
601 E. 12T
H S
TR
EE
T
U.S.
AR
MY C
OR
PS O
F E
NGIN
EE
RS
RO
OF P
LA
N
M M
CC
OLL
UM
819 T
AY
LO
R S
TR
EE
T
AE120
A
0 824 168
" = 1'-0"81SCALE:
NORTH
PLAN
N
AE121AE120
1
SCALE: 1/8" = 1'-0"
PARTIAL ROOF PLAN
KEY PLAN
FO
R M
AT
CH LIN
E
RE:A
E122
A
AE121 AE430
A
CLLC
LC LC
METAL FASCIA
4x6 METAL GUTTER
LC LC LC LC
4x6 METAL GUTTER 4x6 METAL GUTTER
4x6 METAL GUTTER
LC
2
AE121 AE570
GENERAL SHEET NOTES
5. RE: ELECTRICAL FOR LIGHTNING PROTECTION.
PENETRATION LOCATIONS.
4. RE: MECHANICAL & PLUMBING FOR ROOF
INFORMATION.
SKYLIGHTS, AND AE570 FOR ADDITIONAL SKYLIGHT
3. REFERENCE SPECIFICATION 08 60 45
FASCIA.
2. DIMENSIONS PROVIDED ARE FROM EDGE OF
OTHERWISE.
CENTERLINE OF THE NEAREST GRID UNLESS NOTED
1. CENTERLINES OF DOWNSPOUTS ARE AT THE
RE: 4/ AE570
METAL RIDGE
RE: 3/ AE570
@ RADIANT HEATERS, TYP.
MECHANICAL INTAKE/ EXHAUST
RE: 7/AE570
SKYLIGHT TYP
SEAM METAL ROOF
STEEL STANDING
SEAM METAL ROOF
STEEL STANDING
SEAM METAL ROOF
STEEL STANDING
U.S.
AR
MY C
OR
PS O
F E
NGIN
EE
RS
FO
RT W
OR
TH, T
X 7
6102
PN: 00000
CO
S S
TA
ND
AR
D D
ESIG
N
CLIM
AT
E Z
ON
E 3
B – F
T B
LIS
S T
X
SS
A W
AR
EH
OU
SE 4
4220
Fort Worth District
1:1OC
TO
BE
R 2
012
M C
OA
TE
S
M M
CC
OLL
UM
J P
ET
RY
SS
A_3
B-A
E121.d
gn
KA
NS
AS CIT
Y,
MO 6
4106
601 E. 12T
H S
TR
EE
T
U.S.
AR
MY C
OR
PS O
F E
NGIN
EE
RS
PA
RTIA
L R
OO
F P
LA
N
M M
CC
OLL
UM
819 T
AY
LO
R S
TR
EE
T
AE121
US Army Corps
of Engineers
AP
PR.
DA
TE
DE
SC
RIP
TIO
NS
YM
Desig
ned b
y:
Date:
Dra
wn b
y:
Dra
win
g c
ode:
Plot scale:
Checked b
y:
Sub
mitte
d b
y:
CA
DD File N
am
e:
NUMBER
SHEET
pw:\\NWK-AP-ED-PWINT.nwk.ds.usace.army.mil:PWNWK00\Documents\MIL\SWF COS Designs\SSA Warehouse\6.0 Engineering & Design\6.1-NWK\CAD_BIM\_Sheets 3B\SSA_3B-AE121.dgn
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
10/24/2012 11:07:16 AM
24'-2"
4'-0"
1'-2" 12'-6" 12'-6" 12'-6"12'-6"
12'-6" TYP
DS
AE121 AE431
E
1/1
2 S
LO
PE
1/1
2 S
LO
PE
DS DS
DS DS
DS
26'-0"
1'-0"
1'-2" 1'-0"
DSDS
DSDS
4'-0"
8'-0"
MECHANICAL UNIT
4x6 METAL GUTTER
MECHANICAL UNIT
US Army Corps
of Engineers
AP
PR.
DA
TE
DE
SC
RIP
TIO
NS
YM
Desig
ned b
y:
Date:
Dra
wn b
y:
Dra
win
g c
ode:
Plot scale:
Checked b
y:
Sub
mitte
d b
y:
CA
DD File N
am
e:
NUMBER
SHEET
pw:\\NWK-AP-ED-PWINT.nwk.ds.usace.army.mil:PWNWK00\Documents\MIL\SWF COS Designs\SSA Warehouse\6.0 Engineering & Design\6.1-NWK\CAD_BIM\_Sheets 3B\SSA_3B-AE122.dgn
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
10/24/2012 11:08:23 AM
0 824 168
" = 1'-0"81SCALE:
NORTH
PLAN
N
AE122AE120
1
SCALE: 1/8" = 1'-0"
PARTIAL ROOF PLAN
KEY PLAN
LC LC
1/1
2 S
LO
PE
1/1
2 S
LO
PE
12'-6" LC
4'-0"
26'-0"
LC
LC 12'-6" LC
15'-6"
7'-6" LC
8'-0"
4'-0"
MECHANICAL UNIT
METAL RIDGE
4x6 METAL GUTTER4x6 METAL GUTTER
4x6 METAL GUTTER 4x6 METAL GUTTERMETAL FASCIA
12'-6"
LCLC
SKYLIGHT TYP
RE: MECHANICAL
EXHAUST FANS3/ AE410
ROOF ACCESS HATCH
RE: 5/ AE611
SUNSHADE (TYP.)
RE: 5/ AE611
SUNSHADE (TYP.)
RE: 5/ AE611
SUNSHADE (TYP.)
5. RE: ELECTRICAL FOR LIGHTNING PROTECTION.
PENETRATION LOCATIONS.
4. RE: MECHANICAL & PLUMBING FOR ROOF
INFORMATION.
SKYLIGHTS, AND AE570 FOR ADDITIONAL SKYLIGHT
3. REFERENCE SPECIFICATION 08 60 45
FASCIA.
2. DIMENSIONS PROVIDED ARE FROM EDGE OF
OTHERWISE.
CENTERLINE OF THE NEAREST GRID UNLESS NOTED
1. CENTERLINES OF DOWNSPOUTS ARE AT THE
GENERAL SHEET NOTES
RE: 3/ AE570
HEATERS, TYP.
AT RADIANT
INTAKE / EXHAUST
MECHANICAL
RE: 3/ AE570
STACK PENETRATION
PLUMBING VENT
SEAM METAL ROOF
STEEL STANDING
SEAM METAL ROOF
STEEL STANDING
SEAM METAL ROOF
STEEL STANDING
SEAM METAL ROOF
STEEL STANDING
U.S.
AR
MY C
OR
PS O
F E
NGIN
EE
RS
FO
RT W
OR
TH, T
X 7
6102
PN: 00000
CO
S S
TA
ND
AR
D D
ESIG
N
CLIM
AT
E Z
ON
E 3
B – F
T B
LIS
S T
X
SS
A W
AR
EH
OU
SE 4
4220
Fort Worth District
1:1OC
TO
BE
R 2
012
M C
OA
TE
S
M M
CC
OLL
UM
J P
ET
RY
SS
A_3
B-A
E122.d
gn
KA
NS
AS CIT
Y,
MO 6
4106
601 E. 12T
H S
TR
EE
T
U.S.
AR
MY C
OR
PS O
F E
NGIN
EE
RS
PA
RTIA
L R
OO
F P
LA
N
M M
CC
OLL
UM
819 T
AY
LO
R S
TR
EE
T
AE122
A
FO
R M
AT
CH LIN
E
RE:A
E121
A
AE122 AE430
D
4'-0"
10'-0"
10'-0"
4'-0"
4'-0"
12'-8"
4'-0"
4'-8"
4'-0"
1'-0" 1'-2"
1'-2"
3'-0"
3'-0"
1'-0"
12'-6"
D.S. D.S.D.S.
AE122 AE430
B
AE122 AE431
C
D.S. D.S.D.S.
10'-0"
D.S.
SHEET NOTES
HARDWARE SCHEDULE NOTES
W RE: AE111 & AE112.
SYMBOL FOR WINDOW TYPES. 7.
WINDOW DETAILS, AND AE612 FOR LOUVER DETAILS
6. RE: AE610 FOR DOOR DETAILS, AE611 FOR
UNLESS OTHERWISE NOTED.
5. ALL DOORS SHALL HAVE AN STC RATING OF 33,
WITH LIFE SAFETY PLANS.
4. ALL FIRE RATD DOORS SHALL BE COORDINATED
OR CERAMIC RATED GLAZING.
3. FIRE RATED GLAZING SHALL BE WIRE GLASS
SPECIFICATION SECTION 08 11 13.
PERFORMANCE LEVEL AS IDENTIFIED IN THE
2. IN THE DOOR SCHEDULE, LEVEL REFERS TO
OVERHEAD COILING DOORS.
13 STEEL DOORS AND FRAMES, AND 08 33 23
1. REFERENCE SPECIFICATION SECTIONS 08 11
ESCUTCHEON.
FUNCTION 1: EXIT ONLY, NO TRIM OR BLANK
TYPE 3: MORTISE EXIT DEVICE
A156.3-2001)
5. DESCRIPTION OF EXIT DEVICES: (ASNSI/BHMA
LEVER, OUTSIDE LEVER IS ALWAYS INOPERATIVE.
KEY FROM OUTSIDE OR BY OPERATING INSIDE
F07 STOREROOM LOCK: LATCH BOLT OPERATED BY
OPERATING INSIDE LEVER. AUXILIARY DEAD LATCH.
AND OUTSIDE LEVER FROM OUTSIDE OR BY
BY OPERATING KEY, OR PUSH BUTTON MECHANISM,
LOCKED, LATCH BOLT IS RETRACTED BY KEY, OR
PUSH BUTTON MECHANISM. WHEN OUTSIDE LEVER IS
LEVER IS LOCKED FROM OUTSIDE BY A KEY, OR
LEVER FROM EITHER SIDE EXCEPT WHEN OUTSIDE
F05 CLASSROOM LOCK: LATCH BOLT OPERATED BY
OR BY OPERATING INSIDE LEVER.
IS LOCKED, LATCH BOLT IS RETRACTED BY A KEY,
MEANS OTHER THAN A KEY. WHEN OUTSIDE LEVER
IS MADE INOPERATIVE BY A STOP OR MECHANICAL
FROM EITHER SIDE EXCEPT WHEN OUTSIDE LEVER
F04 ENTRY LOCK: LATCH BOLT OPERATED BY LEVER
(ANSI/BHMA A156.13-2005)
4. DESCRIPTION OF MORTISE LOCK SERIES 1000:
3. ALL INTERIOR DOORS SHALL HAVE SILENCERS.
2. PROVIDE 2 SPARE LOCK SETS OF EACH TYPE.
AND FACILITIES.
(ADA) ACCESSIBILITY GUIDELINES FOR BUILDINGS
36 CFR 1191, AMERICANS WITH DISABILITIES ACT
FEDERAL ACCESSIBILITY STANDARDS (UFAS) AND
ACCESSIBILITY REQUIREMENTS OF THE UNIFORM
1. SELECTED HARDWARE SHALL CONFORM WITH
OVERHEAD DOORS
OVERHEAD COILING DOORS & 08 36 13 SECTIONAL
BY OH MANUFACTURER. RE: SPEC: 08 33 23
B. OVERHEAD DOORS, HARDWARE TO BE PROVIDED
SHALL BE PROVIDED AT HARDWARE
A. DOORS ARE WIRE MESH TYPE. METAL PLATE
U.S.
AR
MY C
OR
PS O
F E
NGIN
EE
RS
FO
RT W
OR
TH, T
X 7
6102
PN: 00000
CO
S S
TA
ND
AR
D D
ESIG
N
CLIM
AT
E Z
ON
E 3
B – F
T B
LIS
S T
X
SS
A W
AR
EH
OU
SE 4
4220
Fort Worth District
1:1OC
TO
BE
R 2
012
M C
OA
TE
S
M M
CC
OLL
UM
J P
ET
RY
SS
A_3
B-A
E600.d
gn
KA
NS
AS CIT
Y,
MO 6
4106
601 E. 12T
H S
TR
EE
T
U.S.
AR
MY C
OR
PS O
F E
NGIN
EE
RS
SC
HE
DU
LE
S
M M
CC
OLL
UM
819 T
AY
LO
R S
TR
EE
T
AE600
US Army Corps
of Engineers
AP
PR.
DA
TE
DE
SC
RIP
TIO
NS
YM
Desig
ned b
y:
Date:
Dra
wn b
y:
Dra
win
g c
ode:
Plot scale:
Checked b
y:
Sub
mitte
d b
y:
CA
DD File N
am
e:
NUMBER
SHEET
$FILEL$
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
$DATE$ $TIME$
SHEET NOTES: REMARKS:
U.S.
AR
MY C
OR
PS O
F E
NGIN
EE
RS
FO
RT W
OR
TH, T
X 7
6102
PN: 00000
CO
S S
TA
ND
AR
D D
ESIG
N
CLIM
AT
E Z
ON
E 3
B � F
T B
LIS
S T
X
SS
A W
AR
EH
OU
SE 4
4220
Fort Worth District
1:1OC
TO
BE
R 2
012
M C
OA
TE
S
C L
EWIS
N B
UR
MA
N
SS
A_3
B-I
N601.d
gn
KA
NS
AS CIT
Y,
MO 6
4106
601 E. 12T
H S
TR
EE
T
U.S.
AR
MY C
OR
PS O
F E
NGIN
EE
RS
INT
ERIO
R FINIS
H S
CH
ED
ULE
C L
EWIS
819 T
AY
LO
R S
TR
EE
T
IN601
US Army Corps
of Engineers
AP
PR.
DA
TE
DE
SC
RIP
TIO
NS
YM
Desig
ned b
y:
Date:
Dra
wn b
y:
Dra
win
g c
ode:
Plot scale:
Checked b
y:
Sub
mitte
d b
y:
CA
DD File N
am
e:
NUMBER
SHEET
c:\bentley_work\pw_working\g5eddcl9\cenwk00\dms33796\SSA_3B-IN601.dgn
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
10/23/2012 10:18:51 PM