SRICM-BU-ENG-3479.pdf 01/16 (Issue 1) Milwaukee, WI 53235, USA Tel: +1 (414) 769-6400 [email protected] St. Ives, Cambs. PE27 3LZ, UK Tel: +44 (0) 1480 397 400 [email protected] www.webtec.com Certificate No.8242 Hydraulic measurement and control Features l Measures and displays NAS 1638 as standard (other options available – please consult sales office). l Moisture and temperature sensing fluid dependant l Multicolour LED indication l Robust die cast aluminium construction l Up to 400 bar maximum pressure. l IP65 rated. l No external power supply. System is powered from the HPM6000. The SR-ICM measures and displays particulate contamination, moisture and temperature levels in hydraulic fluids. These values are transmitted and displayed on the HPM6000 where they can be logged. It is designed specifically to be mounted directly to systems, where ongoing measurement or analysis is required, and where space is limited. The kit comprises a Contamination Monitor and a USB interface box (with connecting cables). HPM6000 Sold Separately

Upload: trandiep

Post on 03-Jan-2019

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SR - ICM - hydroflex.nl · BS2X34B, MM0114 & SP-J-513-083 T. II CI. A Performance: MIL-PRF-85285 Fluid Compatibility Mineral Oil Hydraulic Connections Minimess connections M16 x 2

SRICM-BU-ENG-3479.pdf 01/16(Issue 1)

SR - ICMInline Contamination Monitor Kit for HPM6000

Milwaukee, WI 53235, USATel: +1 (414) [email protected]

St. Ives, Cambs. PE27 3LZ, UKTel: +44 (0) 1480 397 [email protected]

www.webtec.com

Certificate No.8242

Hydraulic measurement and control

Featuresl Measures and displays

NAS 1638 as standard (other options available – please consult sales office).

l Moisture and temperature sensing fluid dependant

l Multicolour LED indication

l Robust die cast aluminium construction

l Up to 400 bar maximum pressure.

l IP65 rated.

l No external power supply. System is powered from the HPM6000.

The SR-ICM measures and displays particulate contamination, moisture and temperature levels in hydraulic fluids. These values are transmitted and displayed on the HPM6000 where they can be logged.

It is designed specifically to be mounted directly to systems, where ongoing measurement or analysis is required, and where space is limited.

The kit comprises a Contamination Monitor and a USB interface box (with connecting cables).

HPM6000 Sold Separately

Page 2: SR - ICM - hydroflex.nl · BS2X34B, MM0114 & SP-J-513-083 T. II CI. A Performance: MIL-PRF-85285 Fluid Compatibility Mineral Oil Hydraulic Connections Minimess connections M16 x 2

SpecificationsICMTechnology: LED Based Light Extinction Automatic Optical Contamination MonitorMaximum Pressure: Up to 400 bar (5800 PSI)Operating Flow Rate: 20 - 400 ml/minuteParticle Sizing: >4,6,14,21,25,38,50,70 μm(c) to ISO 4406 StandardAnalysis range*: ISO 4406 Code 0 to 25, NAS 1638 Class 00 to 12, AS4059 Rev.E. Table 1&2 Sizes A-F: 000 to 12 ISO 11218 00-12 (Lower Limits are Test Time dependent)Accuracy: ± ½ code for 4,6,14um(c) ± 1 code for larger sizesFluid Temperature: From +25°C to +80°CViscosity Range ≤ 1000 cStMoisture Sensing % RH (Relative Humidity) ±3%Temp. Measurement ±3°CFlow rate measurement Indicator onlyAmbient Temp.min/max From -25°C to +55°CEnvironmental Protection IP 65 IK04 Impact ProtectionWeight: 1.15 kgOuter Casing Finish Polyurethane BS X34B. Colour BS381-638 (Dark Sea Grey) Approval: BS2X34A & BS2X34B, MM0114 & SP-J-513-083 T. II CI. A Performance: MIL-PRF-85285Fluid Compatibility Mineral OilHydraulic Connections Minimess connections M16 x 2Electric Connections Connecting cable between USB interface box and ICM 3m long. Connecting cable between USB interface box and HPM6000 5m long as standard. Consult sales for other lengths.*Only NAS code is transmitted to the HPM6000 as standard. Other options available – please consult sales office.

ICM USBi 800 Interface BoxAmbient Temperature -25 to 80 °CAnalogue Output Channels 80-10V Analogue Voltage Accuracy ±20mV (0.2% of full scale)

Dimensions (mm):

Page 3: SR - ICM - hydroflex.nl · BS2X34B, MM0114 & SP-J-513-083 T. II CI. A Performance: MIL-PRF-85285 Fluid Compatibility Mineral Oil Hydraulic Connections Minimess connections M16 x 2

Installation Guidance:

l For optimum performance it is recommended 1 bar differential across the ICMl Avoid installing the ICM close to pump outlets (In some circumstances pump ripple can have

an effect on particle count)l For best results a check valve (1 to 2 bar approx.) should be installed on the return line to

reduce the risk of air backflow.

The above information is for guidance only. Due to the nature of variation in hydraulic systems, this guidance may only be considered as “typical”. System positioning, circuit design, dimensions, pressure settings, viscosities and installation practices are only some of the variables which can be encountered on hydraulic systems industry wide. Users should always consider the specifics of their installation and make adjustments where necessary to ensure the correct and safe operation of components on the circuit. Webtec, MP Filtri UK Ltd and the MP Filtri Ltd Group accept no responsibility for the design, manufacture or installation of systems or circuits where our products may be applied.

Webtec reserve the right to make improvements and changes to the specification without notice