sps synchrotron light monitor -bsr- status g. trad e. bravin, a. goldblatt, f. roncarolo
TRANSCRIPT
![Page 1: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/1.jpg)
SPS Synchrotron Light Monitor-BSR-Status
G. TRADE. Bravin, A. Goldblatt, F. Roncarolo
![Page 2: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/2.jpg)
2SPS BSR Status, G. Trad 04 /02/2015
Content
System Description Location Components
Commissioning SR Intensity
Status
Outlook Batmon Readings
Summary
![Page 3: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/3.jpg)
s
3
SystemDescription
Commissioning
Status
Outlook
SPSLayout
BSR
3SPS BSR Status, G. Trad 04 /02/2015
![Page 4: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/4.jpg)
SR Monitor
Light Source
SR extraction
Optical Systems Detector
SystemDescription
Commissioning
Status
Outlook
4SPS BSR Status, G. Trad 04 /02/2015
![Page 5: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/5.jpg)
• Critical wavelength emitted (even at the flat top energy 28 µm) is far from the detectable range
• Expected light results to be the Edge radiation
• Short distance between the two dipoles lead to interference phenomena
System DescriptionSystemDescription
Commissioning
Status
Outlook
5SPS BSR Status, G. Trad 04 /02/2015
![Page 6: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/6.jpg)
integrated energy per turn over the detectable range in function of the energy
α ɣ12.8
• From E≈400 GeV the emitted light is comparable to the LHC emitted by the LHC undulator at 450 GeV
• Therefore it is reasonable to foresee an SR monitor at flattop energy in the SPS
SR Source SimulationSystemDescription
Commissioning
Status
Outlook
6SPS BSR Status, G. Trad 04 /02/2015
![Page 7: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/7.jpg)
SystemDescription
Commissioning
Status
Outlook
s
80/ mm
96 mm
100
mm
SR Light
Towards optical system
Beam
axi
s
Mirr
or a
xis
View
Port
7SPS BSR Status, G. Trad 04 /02/2015
![Page 8: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/8.jpg)
SystemDescription
Commissioning
Status
Outlook
8SPS BSR Status, G. Trad 04 /02/2015
![Page 9: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/9.jpg)
Shielded Optical Table
Motorized Steering mirror
Extraction Mirror
SR Light
SystemDescription
Commissioning
Status
Outlook
9SPS BSR Status, G. Trad 04 /02/2015
![Page 10: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/10.jpg)
SystemDescription
Commissioning
Status
Outlook
10SPS BSR Status, G. Trad 04 /02/2015
![Page 11: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/11.jpg)
SR LightIntensified gated CCD(Motorized)
Filters : ND+ColorOn motorized wheel
Ocular Lens for zoom(motorized)
Apochromat Lens
SystemDescription
Commissioning
Status
Outlook
11SPS BSR Status, G. Trad 04 /02/2015
![Page 12: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/12.jpg)
Calibration Target for magnification
Calculation
SystemDescription
Commissioning
Status
Outlook
12SPS BSR Status, G. Trad 04 /02/2015
![Page 13: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/13.jpg)
Imaged SPS SR light for a bunch of 1011 protons over 4 SPS turnsalong the energy ramp.
SR Source MeasurementSystemDescription
Commissioning
Status
Outlook
13SPS BSR Status, G. Trad 04 /02/2015
![Page 14: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/14.jpg)
measured
predictedobserved
Measured SR intensity integrated over the detector area
SR Source MeasurementSystemDescription
Commissioning
Status
Outlook
14SPS BSR Status, G. Trad 04 /02/2015
![Page 15: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/15.jpg)
• Hardware Fully installed for a flattop measurement
• Software missing for a safe image acquisition with no expert tools
• Hardware missing for a continuous measurement along the ramp• (function generator for the gain control).
• If optimized acquisition could reach 30 frames per seconds (expert tools)
StatusSystem
Description
Commissioning
Status
Outlook
15SPS BSR Status, G. Trad 04 /02/2015
![Page 16: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/16.jpg)
OUTLOOK
![Page 17: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/17.jpg)
CROSS CALIBRATION WITH WS (s) FOR RESOLUTION MEASUREMENTS
17SPS BSR Status, G. Trad 04 /02/2015
![Page 18: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/18.jpg)
Dispersion is important in the horizontal planeNeeded a good (delta p)/p knowledge
18SPS BSR Status, G. Trad 04 /02/2015
![Page 19: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/19.jpg)
Possible Installation of a high frame rate digital camera (1000 fps)
SystemDescription
Commissioning
Status
Outlook
19SPS BSR Status, G. Trad 04 /02/2015
![Page 20: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/20.jpg)
SPARE
![Page 21: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/21.jpg)
![Page 22: SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo](https://reader036.vdocuments.site/reader036/viewer/2022062422/56649f045503460f94c187f1/html5/thumbnails/22.jpg)