spectroscopic observations (massey & hanson 2011, arxiv 1010.5270v2.pdf) examples of...
TRANSCRIPT
![Page 1: Spectroscopic Observations (Massey & Hanson 2011, arXiv 1010.5270v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration](https://reader034.vdocuments.site/reader034/viewer/2022051316/56649eb65503460f94bc07b1/html5/thumbnails/1.jpg)
Spectroscopic Observations(Massey & Hanson 2011, arXiv 1010.5270v2.pdf)
Examples of SpectrographsSpectroscopy with CCDs
Data Reduction and CalibrationSoftware Resources
1
![Page 2: Spectroscopic Observations (Massey & Hanson 2011, arXiv 1010.5270v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration](https://reader034.vdocuments.site/reader034/viewer/2022051316/56649eb65503460f94bc07b1/html5/thumbnails/2.jpg)
Spectrograph Examples:LHIRES III on HLCO 20-inch
• Classical Czerny-Turner made by Shelyak• 2400, 600, 150 groves per mm gratings
maximum R = 18000• two slit plates • used with SBIG CCD camera for data and
WATEC IZON webcam for acquisition/guiding• For details see Jenkins 2011 M.S. thesis:
http://scholarworks.gsu.edu/phy_astr_theses/12/
2
![Page 3: Spectroscopic Observations (Massey & Hanson 2011, arXiv 1010.5270v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration](https://reader034.vdocuments.site/reader034/viewer/2022051316/56649eb65503460f94bc07b1/html5/thumbnails/3.jpg)
http://www.astrosurf.com/thizy/lhires3/index-en.html3
![Page 4: Spectroscopic Observations (Massey & Hanson 2011, arXiv 1010.5270v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration](https://reader034.vdocuments.site/reader034/viewer/2022051316/56649eb65503460f94bc07b1/html5/thumbnails/4.jpg)
4
Telescope focus
Guider
CCD
Micrometer to set the grating angle
![Page 5: Spectroscopic Observations (Massey & Hanson 2011, arXiv 1010.5270v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration](https://reader034.vdocuments.site/reader034/viewer/2022051316/56649eb65503460f94bc07b1/html5/thumbnails/5.jpg)
5
![Page 6: Spectroscopic Observations (Massey & Hanson 2011, arXiv 1010.5270v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration](https://reader034.vdocuments.site/reader034/viewer/2022051316/56649eb65503460f94bc07b1/html5/thumbnails/6.jpg)
MTT Spectrograph at HLCO:Ebert-Fastie design
• Fiber fed slit composed of 9 vertical fibers• Single mirror for collimator/camera • Four gratings: 2160 (Lowell), 1200, 600, 50
for R= 40000, 19000, 9000, and 500 (m=1)• Variety of order sorting filters• Ph.D. dissertations of Don Barry (1996) and
Reed Riddle (2000)
6
![Page 7: Spectroscopic Observations (Massey & Hanson 2011, arXiv 1010.5270v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration](https://reader034.vdocuments.site/reader034/viewer/2022051316/56649eb65503460f94bc07b1/html5/thumbnails/7.jpg)
7
Barry et al. 2002, PASP, 114, 198
![Page 8: Spectroscopic Observations (Massey & Hanson 2011, arXiv 1010.5270v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration](https://reader034.vdocuments.site/reader034/viewer/2022051316/56649eb65503460f94bc07b1/html5/thumbnails/8.jpg)
Prism spectrogaphs
• dβ/dλ proportional to 1/λ3
• Objective prism of trailed stars, record low resolution
• grism = prism with gratingon one face
• grens = lens plus transmission grating
8
http://www.oasi.org.uk/Obsvns/20131113_spectra/20131113_spectra.shtml
![Page 9: Spectroscopic Observations (Massey & Hanson 2011, arXiv 1010.5270v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration](https://reader034.vdocuments.site/reader034/viewer/2022051316/56649eb65503460f94bc07b1/html5/thumbnails/9.jpg)
Fourier Spectroscopy
• Michelson interferometer (interference from path length difference)
• recorded intensity is FT of spectrum• useful in IR; no slit so very efficient
9
![Page 10: Spectroscopic Observations (Massey & Hanson 2011, arXiv 1010.5270v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration](https://reader034.vdocuments.site/reader034/viewer/2022051316/56649eb65503460f94bc07b1/html5/thumbnails/10.jpg)
Fabry Perot Interferometer
• produces interference rings (one per order)• result is convolution of image and rings• very spacing of etalons or refractive index of gas between
lenses to scan image in wavelength(ex. velocity mapping of nebula in a single emission line)
10
http://hyperphysics.phy-astr.gsu.edu/hbase/phyopt/fabry.html
![Page 11: Spectroscopic Observations (Massey & Hanson 2011, arXiv 1010.5270v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration](https://reader034.vdocuments.site/reader034/viewer/2022051316/56649eb65503460f94bc07b1/html5/thumbnails/11.jpg)
Multi-slit spectrographs
• multiple spectra in a single exposure• OK if FOV is small, number of targets is large• build metallic mask for focal plane with small
“slitlets” at target locations and circular apertures at positions of guide stars
• central wavelengths shifted by spatial position• ex. GMOS/Gemini, IMACS/Magellan
11
![Page 12: Spectroscopic Observations (Massey & Hanson 2011, arXiv 1010.5270v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration](https://reader034.vdocuments.site/reader034/viewer/2022051316/56649eb65503460f94bc07b1/html5/thumbnails/12.jpg)
Multi-object fiber-fed spectrographs
• again multiple spectra in a single exposure• OK with larger FOV, smaller number of targets• micropositioner movers fiber input positions
to positions of targets in focal plane (or used with a plug-board grid)
• output end of fibers stacked in a slit at spectrograph entrance
• ex. Hectospec/MMT, Hydra/WIYN
12
![Page 13: Spectroscopic Observations (Massey & Hanson 2011, arXiv 1010.5270v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration](https://reader034.vdocuments.site/reader034/viewer/2022051316/56649eb65503460f94bc07b1/html5/thumbnails/13.jpg)
Integral Field Spectroscopy
• Obtain spectra at each spatial position in a grid over a small portion of the sky (few arcsec)
• microlens array• fiber bundle • combination of above
(FLAMES/VLT, GMOS/Gemini)• image slicers: sky is sampled by a stack of long,
thin mirrors, each of which is rotated with respect to its neighbors (NIFS/Gemini)
13
![Page 14: Spectroscopic Observations (Massey & Hanson 2011, arXiv 1010.5270v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration](https://reader034.vdocuments.site/reader034/viewer/2022051316/56649eb65503460f94bc07b1/html5/thumbnails/14.jpg)
Spectroscopy with CCD Detectors• format, pixel size, spectral DQE• read noise, full well potential• data frames (“object” with overscan)• bias frames (zero exposure)• bad pixel mask• dark frames • flat fields (featureless and twilight)• wavelength comparison spectra• spectrophotometric flux standard stars
14
![Page 15: Spectroscopic Observations (Massey & Hanson 2011, arXiv 1010.5270v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration](https://reader034.vdocuments.site/reader034/viewer/2022051316/56649eb65503460f94bc07b1/html5/thumbnails/15.jpg)
Reduction and Calibration Steps
• fit and subtract overscan region• trim• dark subtract• interpolate over bad pixels• construct a master bias frame• construct a normalized featureless flat field;
sometimes flat division done after spectrum extraction in echelle and multi-object spectra
• construct illumination correction (long slit)
15
![Page 16: Spectroscopic Observations (Massey & Hanson 2011, arXiv 1010.5270v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration](https://reader034.vdocuments.site/reader034/viewer/2022051316/56649eb65503460f94bc07b1/html5/thumbnails/16.jpg)
Reduction and Calibration Steps• identification of stellar and sky locations across
the image• spectrum extraction by summation over spatial
direction, or better use weighted or“optimal” extraction = spatial profile fit(helps with cosmic ray removal)
• extract wavelength comparison spectra• apply wavelength calibration
(heliocentric or barycentric correction)• apply flux calibration (or rectify spectra)
16
![Page 17: Spectroscopic Observations (Massey & Hanson 2011, arXiv 1010.5270v2.pdf) Examples of Spectrographs Spectroscopy with CCDs Data Reduction and Calibration](https://reader034.vdocuments.site/reader034/viewer/2022051316/56649eb65503460f94bc07b1/html5/thumbnails/17.jpg)
Software Packages• IRAF = Image Reduction and Analysis Facility
http://iraf.noao.edu/docs/spectra.html• IDL = Interactive Data Language
IDL Astronomy Users Libraryhttp://idlastro.gsfc.nasa.gov/other_url.html
• Python – PySpecKithttp://www.astropython.org/resources
• General tips at AstroBetterhttp://www.astrobetter.com/
• Astrophysics Source Code Libraryhttp://asterisk.apod.com/wp/?page_id=12
17