Section lll:Section lll:Section lll:Section lll:Section lll:SM Series SpectrSM Series SpectrSM Series SpectrSM Series SpectrSM Series Spectrometerometerometerometerometersssss
SPECSPECSPECSPECSPECTROMETERSTROMETERSTROMETERSTROMETERSTROMETERSSM200SM200SM200SM200SM200
OEM Packaged Fiber Optic CCDSM240SM240SM240SM240SM240
Hand-Held CCDSM24SM24SM24SM24SM2411111
Near Infrared Enhanced CCDAD300AD300AD300AD300AD300
Back Thinned CCD Tunable, TE CooledSM300SM300SM300SM300SM300
Fluorencenced/RamanSM30SM30SM30SM30SM3011111
PbS ArraySM302SM302SM302SM302SM302
InGaAs ArraySM520SM520SM520SM520SM520
High Resolution CCD
SM SERIES ACCESSORIESSM SERIES ACCESSORIESSM SERIES ACCESSORIESSM SERIES ACCESSORIESSM SERIES ACCESSORIES
SM SERIES SOFTWSM SERIES SOFTWSM SERIES SOFTWSM SERIES SOFTWSM SERIES SOFTWAREAREAREAREARE
SPECTRAL PRODUCTS
34Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
SM200SM200SM200SM200SM200OEM packOEM packOEM packOEM packOEM packaged Fiber Optic CCD Spectraged Fiber Optic CCD Spectraged Fiber Optic CCD Spectraged Fiber Optic CCD Spectraged Fiber Optic CCD Spectrometerometerometerometerometer
• Best performance cost ratio
in the industry.
• Designed from the ground up
for OEM integration.
• Small impact resistant optical
bench.
• Flexible light input direct to slit or
via fiber.
• Fully customizable.
• ILX 511 allows up to a 700 nm
measurement window between
200nm and 1050nm (800 nm
measurement window size possible
for some applications).
• USB 2.0 interface with 16-bit
dynamic range available!
The Choice fThe Choice fThe Choice fThe Choice fThe Choice for OEM Spectror OEM Spectror OEM Spectror OEM Spectror OEM SpectralalalalalApplicationsApplicationsApplicationsApplicationsApplications
revised 6/03
The SM200 is a miniature spectrometer designed for custom OEM
applications. It offers a high performance to cost ratio for new systems designs.
The SM200 can accept light directly through its built-in slit or via optical fiber. A
removable fiber coupler faceplate allows use of standard SMA 905, FC and
custom fiber connectors. This faceplate also allows direct attachment to dedicated
systems and a number of SMX Accessories. A durable aluminum housing encloses
the SM200 optical bench; through careful design this housing provides stable
device operation over a wide range of temperatures.
The spectrometer sensor array and array driver electronics are mounted
inside the SM200 housing, from there a flex cable connects to exterior support
electronics. The standard sensor array used is the Sony ILX 511. The driver
electronics have been designed for highly sensitive yet stable operation. The
design of the SM200 also allows the use of custom arrays for special applications,
including photodiode assemblies and alternative CCD arrays.
Standard interfaces to the SM200 include a USB 2.0 interface with 16-bit
extended dynamic range and a PCI card interface with 12-bit dynamic range
sampling. Custom interfaces and legacy ISA and PCMCIA interfaces are available.
Software support includes custom DLLs for dedicated applications
development and our SM32Pro windows based spectral acquisition and analysis
software. Both standard and legacy interface designs provide support for advanced
acquisition programming and external triggering.
SPECTRAL PRODUCTS
35Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
Specifications:Specifications:Specifications:Specifications:Specifications:Detectors:Detectors:Detectors:Detectors:Detectors:
Sony CCD Linear ASony CCD Linear ASony CCD Linear ASony CCD Linear ASony CCD Linear ArrayrrayrrayrrayrrayNumber of Pixels: 2048Sensing Pixel Size: 14µm x 200µmSensitivity: 1800 V/(lx•s) @ 660nmCustomer array installation availableCustomer array installation availableCustomer array installation availableCustomer array installation availableCustomer array installation available
Computer Interface:Computer Interface:Computer Interface:Computer Interface:Computer Interface:USB 2.0USB 2.0USB 2.0USB 2.0USB 2.0 16 bit 500KHzPCI busPCI busPCI busPCI busPCI bus NI-PCI 12 bit 100 KHz
PCI interface boardCall SP for other interface options,Call SP for other interface options,Call SP for other interface options,Call SP for other interface options,Call SP for other interface options,including PCMCIA and ISAincluding PCMCIA and ISAincluding PCMCIA and ISAincluding PCMCIA and ISAincluding PCMCIA and ISA
Temperature Induced Shift:Temperature Induced Shift:Temperature Induced Shift:Temperature Induced Shift:Temperature Induced Shift: 0.01 nm /°CSpectrograph f#:Spectrograph f#:Spectrograph f#:Spectrograph f#:Spectrograph f#: 2.7Available Gratings:Available Gratings:Available Gratings:Available Gratings:Available Gratings: See Appendix ASlit Options:Slit Options:Slit Options:Slit Options:Slit Options: 10, 25, 50 or 100µmFiber Options:Fiber Options:Fiber Options:Fiber Options:Fiber Options: 50 to 600µm core diameterFiber Coupler:Fiber Coupler:Fiber Coupler:Fiber Coupler:Fiber Coupler: SMA 905 or FC standard,
custom coupler availableFiber Numerical Aperture:Fiber Numerical Aperture:Fiber Numerical Aperture:Fiber Numerical Aperture:Fiber Numerical Aperture: 0.2Effective Spectral Range:Effective Spectral Range:Effective Spectral Range:Effective Spectral Range:Effective Spectral Range: 200 to 1050nmOrder Sorting Filter:Order Sorting Filter:Order Sorting Filter:Order Sorting Filter:Order Sorting Filter: Longpass filter installed
per wavelength coverageSpectral Resolution:Spectral Resolution:Spectral Resolution:Spectral Resolution:Spectral Resolution: 0.3 to 10nm depending on
the slit and grating choicesStray Light:Stray Light:Stray Light:Stray Light:Stray Light: <0.01% at 600nmSoftware:Software:Software:Software:Software: SM32Pro (free with spectrometer)
Includes SDK and DLLs for easycustom application development.
0.905
2.000 2.689
0.329
Ø 0.174
1.570
3.813
0.492
2.078
Ordering Information: Please indicate productnumber plus description when ordering.
SM200SM200SM200SM200SM200 OEM Fiber Optic Spectrometer
revised 6/03
SPECTRAL PRODUCTS
36Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
SM240SM240SM240SM240SM240Hand-held CCD SpectrHand-held CCD SpectrHand-held CCD SpectrHand-held CCD SpectrHand-held CCD Spectrometerometerometerometerometer
The SM240 is a compact CCD Spectrometer for use with a PC. Based on the
SM200SM200SM200SM200SM200 optical bench design, it supports many different applications where
spectral or color measurements are required, including high dynamic range
applications.
The SM240 can accept light directly through its built-in slit or via optical
fiber. A removable faceplate allows the use of standard SMA 905, FC and custom
fiber connectors. This faceplate also allows direct attachment to dedicated
systems and a number of SMX AccessoriesSMX AccessoriesSMX AccessoriesSMX AccessoriesSMX Accessories. The durable aluminum housing that
encloses the SM240 provides stable optical bench operation over a wide range
of temperatures.
The standard sensor array used is the Sony ILX 511. The array driver
electronics have been designed for highly sensitive yet stable operation. This
array (in conjunction with our special UV coating process and custom order
sorting filters) allows up to a 700nm measurement window located from 200nm
to 1050nm (smaller measurement window sizes increase spectral resolution and
light sensitivity, some laser applications may support a window size of up to
800nm). The design of the SM240 also allows use of custom arrays for special
applications, including photodiode assemblies and alternative CCD arrays.
Standard interfaces to the SM240 include a USB 2.0 interface with 16-bit
extended dynamic range and a PCI card interface with 12-bit dynamic range.
Custom interfaces and legacy ISA and PCMCIA interfaces are available.
Software support includes a SDK and DLLs for dedicated applications
development and our SM32ProSM32ProSM32ProSM32ProSM32Pro Windows-based spectral acquisition and analysis
software. Both standard and legacy interface designs provide support for advanced
acquisition programming and external triggering.
• Compact system, can be handheld
or securely mounted.
• Flexible optical input direct to slit
or via fiber.
• Designed from the ground up
for applications.
• Impact resistant housing.
• High performance electronics.
• Standard design allows up to a
700nm measurement window
between 200nm and 1050nm (800
nm window possible for some
applications).
• USB 2.0 interface with 16-bit
dynamic range available!
The Choice fThe Choice fThe Choice fThe Choice fThe Choice for Spectror Spectror Spectror Spectror Spectral Applicationsal Applicationsal Applicationsal Applicationsal Applications
revised 6/03
SPECTRAL PRODUCTS
37Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
Ordering Information: Please indicate productnumber plus description when ordering.
SM240 USBSM240 USBSM240 USBSM240 USBSM240 USB USB interface, SpectrometerSM240 PCISM240 PCISM240 PCISM240 PCISM240 PCI PCI interface, Spectrometer
Specifications:Specifications:Specifications:Specifications:Specifications:Detectors:Detectors:Detectors:Detectors:Detectors:
Sony CCD Linear ArraySony CCD Linear ArraySony CCD Linear ArraySony CCD Linear ArraySony CCD Linear ArrayNumber of Pixels: 2048Sensing Pixel Size: 14µm x 200µmSensitivity: 1800 V/(lx•s) @ 660nmCustomer array installation availableCustomer array installation availableCustomer array installation availableCustomer array installation availableCustomer array installation available
Dimensions (inches):Dimensions (inches):Dimensions (inches):Dimensions (inches):Dimensions (inches): 5.6 h x 2.75 w x 0.87 dWeight:Weight:Weight:Weight:Weight: 0.5 lbs.Spectral Range:Spectral Range:Spectral Range:Spectral Range:Spectral Range: UV - 200nm to 450nm
VIS - 380nm to 760nmNIR - 550nm to 1050nm
other ranges are configurablefrom 200nm to 1050nm
Spectral Resolution:Spectral Resolution:Spectral Resolution:Spectral Resolution:Spectral Resolution: 0.3 - 10nm dependent onspectral range, slit width, and fiber diameter.
Available Gratings:Available Gratings:Available Gratings:Available Gratings:Available Gratings: See Appendix A
SoftwSoftwSoftwSoftwSoftwararararareeeee✓✓✓✓✓ SM32Pro - Windows® 98,2000, XP
based software for data acquisitionand analysis.
✓✓✓✓✓ Transmission, reflectance, and absorbancemeasurements.
✓✓✓✓✓ Data export, zoom in and out, spectrum overlays, and many more features.
✓✓✓✓✓ Color analysis tools included.✓✓✓✓✓ Signal average and integration time control.✓✓✓✓✓ Double beam version available.✓✓✓✓✓ SDK and DLLs available for easy custom
software development.
Software
�������������
�� ���������
��
�� ���������
��� ���������
����� ���
����� ��
��
revised 6/03
Entrance:Entrance:Entrance:Entrance:Entrance:FiberFiberFiberFiberFiber SMA 905 or FC fiber coupler.
50-600µm core Ø fiberNA = 0.2
SlitSlitSlitSlitSlit 10, 25, 50 or 100µmDynamic Range:Dynamic Range:Dynamic Range:Dynamic Range:Dynamic Range: 12 bit (4096:1) or
16 bit (65536:1)Computer Interface:Computer Interface:Computer Interface:Computer Interface:Computer Interface:
USB 2.0USB 2.0USB 2.0USB 2.0USB 2.0 16 bit 500KHzPCI busPCI busPCI busPCI busPCI bus NI-PCI 12 bit 100 KHz
PCI interface boardCall SP for other interface options,Call SP for other interface options,Call SP for other interface options,Call SP for other interface options,Call SP for other interface options,including PCMCIA and ISAincluding PCMCIA and ISAincluding PCMCIA and ISAincluding PCMCIA and ISAincluding PCMCIA and ISA
Temperature Range:Temperature Range:Temperature Range:Temperature Range:Temperature Range: 15°C to 40°CSoftware:Software:Software:Software:Software: SM32Pro
�����
�����
�����
�����
�����
�����
�����
�����
�����
�����
SPECTRAL PRODUCTS
38Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
SM24SM24SM24SM24SM2411111NIR Laser SpectrNIR Laser SpectrNIR Laser SpectrNIR Laser SpectrNIR Laser Spectrometerometerometerometerometer
The Choice fThe Choice fThe Choice fThe Choice fThe Choice forororororSpectrSpectrSpectrSpectrSpectral NIR Laser Applicationsal NIR Laser Applicationsal NIR Laser Applicationsal NIR Laser Applicationsal NIR Laser Applications
The SM241 is a compact CCD based Spectrometer designed for NIR laser
applications. Spectral Product’s IR up-conversion phosphor CCD coating breaks
the standard Silicon-based CCD detectors array sensitivity barrier of 1100nm to
allow spectral measurements up to 1700nm. This technology makes the SM241
a lower cost alternative to Germanium or InGaAs systems. The SM241 optical
bench includes oversized gold plated mirrors and gratings to accommodate NIR
light collection and analysis. Maximum spectral coverage with this spectrometer
is 900 nm to 1700 nm (reduced coverage window size within 900-1700nm will
increase spectral resolution and light sensitivity).
Standard interfaces include a USB 2.0 interface with a 16-bit extended
dynamic range and a PCI card interface with a 12-bit dynamic range. Custom
interfaces and legacy ISA and PCMCIA interfaces are also available. Software
support includes a SDK and DLLs for dedicated applications development and our
SM32ProSM32ProSM32ProSM32ProSM32Pro windows based spectral acquisition and analysis software. Both standard
and legacy interface designs provide support for advanced acquisition programming
and external triggering.
• Less expensive alternative to
Germanium or InGaAs systems.
• Compact system, can be handheld
or securely mounted.
• Flexible optical input direct to
slit or via fiber.
• High performance electronics.
• Allows spectral measurements
between 900nm and 1700nm.
• USB 2.0 interface with 16-bit
dynamic range available!
revised 6/03
SPECTRAL PRODUCTS
39Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
Specifications:Specifications:Specifications:Specifications:Specifications:# of CCD Pixels:# of CCD Pixels:# of CCD Pixels:# of CCD Pixels:# of CCD Pixels: 2048CCD Pixel Size:CCD Pixel Size:CCD Pixel Size:CCD Pixel Size:CCD Pixel Size: 14µm by 200µmCCD Sensitivity:CCD Sensitivity:CCD Sensitivity:CCD Sensitivity:CCD Sensitivity: 30 V/mJ/cm2
Grating:Grating:Grating:Grating:Grating: 300 to 1800 grooves per mmSpectral Response:Spectral Response:Spectral Response:Spectral Response:Spectral Response: 900nm to 1600nmSpectral Resolution:Spectral Resolution:Spectral Resolution:Spectral Resolution:Spectral Resolution: 5nm with standard slit
configurationAvailable Gratings:Available Gratings:Available Gratings:Available Gratings:Available Gratings: See Appendix AEntrance:Entrance:Entrance:Entrance:Entrance:
SlitSlitSlitSlitSlit 10µm - 100µm FiberFiberFiberFiberFiber SMA fiber coupler, NA = 0.2Stray Light Rejection:Stray Light Rejection:Stray Light Rejection:Stray Light Rejection:Stray Light Rejection: better than 10-3
Analog to Digital:Analog to Digital:Analog to Digital:Analog to Digital:Analog to Digital: USB 16 bit standard,PCI optional.
Digitizer Resolution:Digitizer Resolution:Digitizer Resolution:Digitizer Resolution:Digitizer Resolution: 12-bit, 4096 to 1 or 16 bit, 65536 to 1
Ordering Information: Please indicate productnumber plus description when ordering.
SM241 USBSM241 USBSM241 USBSM241 USBSM241 USB Near Infrared Enhanced Hand-held Spectrometer, USB
SM241 USBSM241 USBSM241 USBSM241 USBSM241 USB Near Infrared Enhanced Hand-held Spectrometer, USB
revised 6/03
�������������
�� ���������
��
�� ���������
��� ���������
����� ���
����� ��
��
Computer Interface:Computer Interface:Computer Interface:Computer Interface:Computer Interface:USB BusUSB BusUSB BusUSB BusUSB Bus 16 bit 500KHzPCI busPCI busPCI busPCI busPCI bus NI-PCI 12 bit 100 KHz
PCI interface boardCall SP for other interface optionsCall SP for other interface optionsCall SP for other interface optionsCall SP for other interface optionsCall SP for other interface options
Dimensions (inches):Dimensions (inches):Dimensions (inches):Dimensions (inches):Dimensions (inches): 5.5 x 2.9 x 0.99Weight:Weight:Weight:Weight:Weight: 0.5 lbs.Software:Software:Software:Software:Software: SM32Pro
SPECTRAL PRODUCTS
40Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
AD300AD300AD300AD300AD300Back Thinned CCD TBack Thinned CCD TBack Thinned CCD TBack Thinned CCD TBack Thinned CCD Tunableunableunableunableunable, TE Cooled Spectr, TE Cooled Spectr, TE Cooled Spectr, TE Cooled Spectr, TE Cooled Spectrometerometerometerometerometer
revised 6/03
• High QE From UV To NIR
• Large Dynamic Range
• Very Low Noise
• 512x122 CCD Format
• Cooled Stable Operation
• Dual Grating Turret Spectrograph
• High Spectral Resolution
The AD300 is a CCD spectrometer system specifically designed for low light
level detection, such as fluorescence and Raman applications. The system
consists of a back-thinned area CCD array, which exhibits high quantum
efficiency and low noise. The array is cooled for noise reduction and long-term
stable operation. The CCD is coupled to a dual grating tunable spectrograph
with computer control to both select grating and wavelength.
The AD300 comes preloaded with two gratings and slit tailored for high-
resolution work throughout the usable range of the detector. Either or both
gratings may be user specified to achieve resolution and desired bandwidth
window onto the array. The standard dual function entrance can accept light
directly coupled through the built-in slit or from a standard fiber. The standard
model comes with a 20µm slit for the highest resolution performance. In
general, in order to maximize thruput, the grating should be selected to
determine bandwidth needed and the largest possible slit should be selected
that produces an acceptable resolution. For a full list of standard available
gratings, please see the grating section in the Appendix A. Other gratings are
available as special orders.
LoLoLoLoLow Light Lew Light Lew Light Lew Light Lew Light Levvvvvel Detection,el Detection,el Detection,el Detection,el Detection,TTTTTunable CCD Spectrunable CCD Spectrunable CCD Spectrunable CCD Spectrunable CCD Spectrometerometerometerometerometer
SPECTRAL PRODUCTS
41Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
revised 6/03
Ordering Information: Please indicate productnumber plus description when ordering.
AD300AD300AD300AD300AD300 Back Thinned CCD Tunable Spectrometer
Grating efficiency curves of standard gratings.1200 groove/mm blazed at 200nm and 500nm.
Specifications:Specifications:Specifications:Specifications:Specifications:CCD Camera (AD202)CCD Camera (AD202)CCD Camera (AD202)CCD Camera (AD202)CCD Camera (AD202)Spectral range:Spectral range:Spectral range:Spectral range:Spectral range: 200 to 1100nm tunableNumber of pixels:Number of pixels:Number of pixels:Number of pixels:Number of pixels: 512 x 122Pixel size:Pixel size:Pixel size:Pixel size:Pixel size: 24 by 24µmWell Depth (eWell Depth (eWell Depth (eWell Depth (eWell Depth (e-----):):):):):
Unbinned:Unbinned:Unbinned:Unbinned:Unbinned: >300,000Binned:Binned:Binned:Binned:Binned: >600,000
Read Noise (eRead Noise (eRead Noise (eRead Noise (eRead Noise (e-----):):):):): 10-15 (typical)Dark Count (eDark Count (eDark Count (eDark Count (eDark Count (e-----/pixel/s):/pixel/s):/pixel/s):/pixel/s):/pixel/s): 4-5@ -20°CDynamic Range:Dynamic Range:Dynamic Range:Dynamic Range:Dynamic Range: >86dBDigital Resolution:Digital Resolution:Digital Resolution:Digital Resolution:Digital Resolution: 16-bit (50kHz)Exposure Time:Exposure Time:Exposure Time:Exposure Time:Exposure Time: 0.03 - 10,400 sec.
(0.010 sec. increments)Cooling:Cooling:Cooling:Cooling:Cooling: -20°C or software programmable to
45°C below ambient.Temperature Stability:Temperature Stability:Temperature Stability:Temperature Stability:Temperature Stability: ±0.1°COperating Environment:Operating Environment:Operating Environment:Operating Environment:Operating Environment:
Temperature:Temperature:Temperature:Temperature:Temperature: -30° to 80° FRelative humidity:Relative humidity:Relative humidity:Relative humidity:Relative humidity: 10 to 90% noncondensing
PC Interface:PC Interface:PC Interface:PC Interface:PC Interface: Parallel port. 10' cable included.Software:Software:Software:Software:Software: KestralSpec
(see Detection Systems section)Options:Options:Options:Options:Options: Remote trigger; remote shutter.
Tunable SpectrographTunable SpectrographTunable SpectrographTunable SpectrographTunable SpectrographDesign:Design:Design:Design:Design: Czerny-Turner, dual grating turretsf#:f#:f#:f#:f#: 3.9Focal length:Focal length:Focal length:Focal length:Focal length: 140mmWavelength accuracy:Wavelength accuracy:Wavelength accuracy:Wavelength accuracy:Wavelength accuracy: 0.2nmWavelength precision:Wavelength precision:Wavelength precision:Wavelength precision:Wavelength precision: 0.2nm
Gratings:Gratings:Gratings:Gratings:Gratings: 1200 grooves /mm at 200nm and1200 grooves /mm at 500nm standard
Stray light rejection:Stray light rejection:Stray light rejection:Stray light rejection:Stray light rejection: better than 10-4
Total Weight:Total Weight:Total Weight:Total Weight:Total Weight: 10lbs.Computer Control:Computer Control:Computer Control:Computer Control:Computer Control: RS232Light entrance:Light entrance:Light entrance:Light entrance:Light entrance: Dual SMA/20µm slits standard.
Other slit or fiber connections available.Available slit sizes:Available slit sizes:Available slit sizes:Available slit sizes:Available slit sizes: 20µm standard. 50µm,
100µm, 0.125mm, 0.150mm, 0.3mm, 0.6mm,1.2mm, and 2.4mm, available.
System RequirementsSystem RequirementsSystem RequirementsSystem RequirementsSystem RequirementsPentium with 16Mb RAM (more recommended)Windows 98/ME/2000/XPUSB Port (for software key)RS232 portParallel port
���
��
��
��
��
�
�������������� ��� �� ���
�����������m��
��
����
���
!"
!��"
#�$
�
������
GratingGratingGratingGratingGrating Spectrograph centerSpectrograph centerSpectrograph centerSpectrograph centerSpectrograph center Resolution (nm) for slits:Resolution (nm) for slits:Resolution (nm) for slits:Resolution (nm) for slits:Resolution (nm) for slits:groove/mmgroove/mmgroove/mmgroove/mmgroove/mm set wavelength (nm)set wavelength (nm)set wavelength (nm)set wavelength (nm)set wavelength (nm) Bandwidth (nm)Bandwidth (nm)Bandwidth (nm)Bandwidth (nm)Bandwidth (nm) 20µm20µm20µm20µm20µm 0.125mm0.125mm0.125mm0.125mm0.125mm 0.3mm0.3mm0.3mm0.3mm0.3mm
1200 250 68 0.2 1 2
500 63 0.2 < 1 2
1050 44 0.1 < 1 < 2
600 250 140 0.4 < 2 5
500 136 0.4 2 5
1050 125 0.3 2 5
300 250 283 0.8 4 10
500 280 0.8 4 10
1050 272 0.8 4 9
SPECTRAL PRODUCTS
42Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
The SM300 is an integrated CCD spectrometer system specifically designed for low light level fluorescence and Ramanmeasurements. The system consists of the AD300 high performance wavelength tunable CCD spectrometer, the AST-XEtunable excitation light source, the AT-SHC4 cuvette sample chamber, and computer interface with Windows basedoperation software. The modular design allows the components to be decoupled and used individually, or in connectionwith a variety of sampling accessories for fluorescence, Raman, reflectance, transmittance, absorbance, and emission
measurements. The versatility of the system is further enhanced by optic fiber coupling capability for unique applications.
TTTTTunable Spectrunable Spectrunable Spectrunable Spectrunable SpectrometerometerometerometerometerThe AD300 module uses a back-thinned area CCD array, which exhibits high quantum efficiency and low noise. The
array is cooled for noise reduction and long-term stable operation. The CCD is coupled to a small CM based dual gratingtunable spectrograph with computer control to both select grating and wavelength. Gratings and slit should be specifiedby user for optimum performance. The AD300 module may be substituted with one of our larger DK series triple gratingspectrographs and cooled CCD camera.
SM300SM300SM300SM300SM300Modular Fluorescence / Raman SpectrometerModular Fluorescence / Raman SpectrometerModular Fluorescence / Raman SpectrometerModular Fluorescence / Raman SpectrometerModular Fluorescence / Raman Spectrometer
• High QE Back-thinned CCD
Spectrometer
• High Dynamic Range
• Low Noise
• Versitile Modular Design
• Flexible Fiber Coupling Optional
• Dual or Triple Grating for High
Resolution Operation
High Quantum EfficiencyHigh Quantum EfficiencyHigh Quantum EfficiencyHigh Quantum EfficiencyHigh Quantum EfficiencyBack-thinned CCD SpectrometerBack-thinned CCD SpectrometerBack-thinned CCD SpectrometerBack-thinned CCD SpectrometerBack-thinned CCD Spectrometer
revised 6/03
GratingGratingGratingGratingGrating Spectrograph centerSpectrograph centerSpectrograph centerSpectrograph centerSpectrograph center Resolution (nm) for slits:Resolution (nm) for slits:Resolution (nm) for slits:Resolution (nm) for slits:Resolution (nm) for slits:groove/mmgroove/mmgroove/mmgroove/mmgroove/mm set wavelength (nm)set wavelength (nm)set wavelength (nm)set wavelength (nm)set wavelength (nm) Bandwidth (nm)Bandwidth (nm)Bandwidth (nm)Bandwidth (nm)Bandwidth (nm) 20µm20µm20µm20µm20µm 0.125mm0.125mm0.125mm0.125mm0.125mm 0.3mm0.3mm0.3mm0.3mm0.3mm
1200 250 68 0.2 1 2
500 63 0.2 < 1 2
1050 44 0.1 < 1 < 2
600 250 140 0.4 < 2 5
500 136 0.4 2 5
1050 125 0.3 2 5
300 250 283 0.8 4 10
500 280 0.8 4 10
1050 272 0.8 4 9
Grating should be selected to give the desired bandwidth. The largest possible slit should be selected that produces an acceptable resolution.
SPECTRAL PRODUCTS
43Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
revised 6/03
Ordering Information: Please indicate productnumber plus description when ordering.
SM300SM300SM300SM300SM300 Fluorescence/Raman SpectrometerSM300-DKSPSM300-DKSPSM300-DKSPSM300-DKSPSM300-DKSP SM300 with triple grating capabilitySM300-DKSP-ISM300-DKSP-ISM300-DKSP-ISM300-DKSP-ISM300-DKSP-I SM300-DKSP with imaging capability
TTTTTunable Exunable Exunable Exunable Exunable Excitcitcitcitcitation Light Souration Light Souration Light Souration Light Souration Light SourcececececeThe AST-XE wavelength
tunable light source consists
of a xenon source coupled to
a CM110 computer controlled
monochromator for high
excitation power output.
Comes standard with two high-
resolution gratings for good coverage 200-1100 nm and
user changeable slit set. Ozone blocking Xenon source
available.
CenterCenterCenterCenterCenter Slit width = 0.125mm Slit width = 0.125mm Slit width = 0.125mm Slit width = 0.125mm Slit width = 0.125mm Slit width = 2.4mm Slit width = 2.4mm Slit width = 2.4mm Slit width = 2.4mm Slit width = 2.4mm
WWWWWaaaaavvvvvelengthelengthelengthelengthelength Bandpass (nm)Bandpass (nm)Bandpass (nm)Bandpass (nm)Bandpass (nm) PPPPPooooowwwwwer (µW)er (µW)er (µW)er (µW)er (µW) Bandpass (nm)Bandpass (nm)Bandpass (nm)Bandpass (nm)Bandpass (nm) PPPPPooooowwwwwer (mW)er (mW)er (mW)er (mW)er (mW)
ASTASTASTASTAST-XE-175EX (200-1-XE-175EX (200-1-XE-175EX (200-1-XE-175EX (200-1-XE-175EX (200-11111100 nm)00 nm)00 nm)00 nm)00 nm)
200nm 0.9 0.2 17.3 0.9
500nm 0.8 2.9 15.6 10.0
Specifications:Specifications:Specifications:Specifications:Specifications:AD300 CCD SpectrometerAD300 CCD SpectrometerAD300 CCD SpectrometerAD300 CCD SpectrometerAD300 CCD SpectrometerCCD Detector (AD202)CCD Detector (AD202)CCD Detector (AD202)CCD Detector (AD202)CCD Detector (AD202)Spectral Range:Spectral Range:Spectral Range:Spectral Range:Spectral Range: 200nm to 1100nmArray (pixels):Array (pixels):Array (pixels):Array (pixels):Array (pixels): 512x122 standardPixel Size (µm):Pixel Size (µm):Pixel Size (µm):Pixel Size (µm):Pixel Size (µm): 24Well Depth (e-):Well Depth (e-):Well Depth (e-):Well Depth (e-):Well Depth (e-): UnbinnedUnbinnedUnbinnedUnbinnedUnbinned >300,000 BinnedBinnedBinnedBinnedBinned >600,000Read Noise (e-):Read Noise (e-):Read Noise (e-):Read Noise (e-):Read Noise (e-): 10-15 (typical)Dark Count (e-/pixel/sec):Dark Count (e-/pixel/sec):Dark Count (e-/pixel/sec):Dark Count (e-/pixel/sec):Dark Count (e-/pixel/sec): 4-5 @ -20° CExposure Time:Exposure Time:Exposure Time:Exposure Time:Exposure Time: 0.03 seconds to 10,400 sec.
(0.010 second increments).Cooling Cooling Cooling Cooling Cooling : -20°C or programmable down to
45° C below ambient temperature.Temperature Stability:Temperature Stability:Temperature Stability:Temperature Stability:Temperature Stability: ±0.1°CSoftware:Software:Software:Software:Software: KestralSpec
(see Detection Systems section)PC Interface:PC Interface:PC Interface:PC Interface:PC Interface: Parallel port, 10' cable included.Operating Environment:Operating Environment:Operating Environment:Operating Environment:Operating Environment:
TemperatureTemperatureTemperatureTemperatureTemperature -30° to 80° F.Relative humidityRelative humidityRelative humidityRelative humidityRelative humidity 10 to 90% noncondensing
Optical SystemOptical SystemOptical SystemOptical SystemOptical SystemDesign:Design:Design:Design:Design: Czerny-Turner, dual grating turretsfffff#:#:#:#:#: 3.9Focal length:Focal length:Focal length:Focal length:Focal length: 140mmWavelength accuracy:Wavelength accuracy:Wavelength accuracy:Wavelength accuracy:Wavelength accuracy: 0.2 nmWavelength precision:Wavelength precision:Wavelength precision:Wavelength precision:Wavelength precision: 0.2 nmSlit:Slit:Slit:Slit:Slit: 20µm, 50µm, 100µm, 0.125mm,
0.150mm, 0.3mm, 0.6mm, 1.2mm,and 2.4mm, please specify.
Stray light rejection:Stray light rejection:Stray light rejection:Stray light rejection:Stray light rejection: better than 10-4
System RequirementsSystem RequirementsSystem RequirementsSystem RequirementsSystem RequirementsPentium with 16Mb RAM (more recommended)Windows 98/ME/2000/XPUSB Port (for software key)Parallel portTwo RS232 ports (one may be eliminated by useof the DK1200 CM Controller, see CM SeriesOptions section)
FFFFFour Pour Pour Pour Pour Port Sampleort Sampleort Sampleort Sampleort SampleChamberChamberChamberChamberChamber
The AT-SCH4 comes configured
with broadband optics optimized for
the right-angle measurement
configuration.
���������� �!���
����
�"#��
��$%����$��
�&'
��'
Dimensions of layout of SM300
SPECTRAL PRODUCTS
44Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
SM30SM30SM30SM30SM3011111PbS ArrPbS ArrPbS ArrPbS ArrPbS Arraaaaay Spectry Spectry Spectry Spectry Spectrometerometerometerometerometer
• Low Noise
• Cooled, Stable Operation
• 256 Detection Elements
• Accommodates spectral
measurements in the
1 to 3 micron range.
• Optical input direct to slit
or via fiber.
The SM301 is a versatile, high performance PbS array spectrometer. Its
active components include a TE cooler and a 256-element PbS detector element
array. Operation of the unit for research applications is easy with the included
Windows based SM32Pro-based analysis software. The system is ideal for
spectroscopic applications in the 1 to 3 micron region.
Available system options include a built-in high-speed shutter and optical
blank pixels for setting dark current offsets. The SM301 includes thermoelectric
cooling to guarantee long-term operational stability.
The Choice fThe Choice fThe Choice fThe Choice fThe Choice for IR Spectror IR Spectror IR Spectror IR Spectror IR SpectralalalalalApplicationsApplicationsApplicationsApplicationsApplications
revised 6/03
SPECTRAL PRODUCTS
45Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
General DescriptionGeneral DescriptionGeneral DescriptionGeneral DescriptionGeneral DescriptionThe SM301 is a complete compact PbS array
Spectrometer for use with a PC to perform spectral
measurements in the region of 1 to 3 microns.
It consists of four parts: 1. an entrance mechanism
with a built-in slit, a fiber coupling adapter, and an order
sorting filter; 2. a spectrograph of a crossed Czerny-
Turner arrangement using high quality optics; 3. a linear
lead sulfite sensor array and driving circuitry; 4. a computer
interface for data acquisition.
All the optical components and driving electronics
are enclosed in an aluminum housing for stable operation.
A thermal electric (TE) cooler is also included.
ApplicationApplicationApplicationApplicationApplicationThe SM301 employs a multiplexed PbS array as its NIR
detection element. The array is cooled and temperature
stabilized at -10 oC which ensures a long-term operation
stability. A built-in mechanical shutter mechanism is controlled
by the system clock and is synchronized with the array
readout operation. Dark signal can thus be automatically
measured by the built-in electronics periodically and subtracted
automatically. Compared with conventional scanning NIR
spectrometers the SM301 provides the multichannel
detection advantage, both in reducing the measurement time
and enhancing measurement signal-to-noise ratio. The SM301
can operate at a readout rate of 100 kHz or faster allowing fast
measurement and averaging operation to be performed in a
short period of time.
A variety of accessories makes the SM301 versatile for
process control, spectroscopy, environmental monitoring,
and other applications. It can easily be configured for
transmission, reflectance, absorbance, and other
measurements. The wavelength range from 1 to 3 µm can be
covered by one grating optimized for the wavelength range.
The spectral range can also be factory configured to meet
application needs.
The SM301 can accept light directly coupled through a
built-in slit, from a fiber through an SMA coupler or both. The
fiber coupling ability makes the unit flexible for remote and
process control applications. Where high mobility is required,
the SM301 can be used with just a slit to eliminate the light
transfer variations caused by the changes in fiber bending
curvatures. As a result, attenuation resulting from the use of
optical fibers can also be avoided.
Specifications:Specifications:Specifications:Specifications:Specifications:Number of pixels:Number of pixels:Number of pixels:Number of pixels:Number of pixels: 256Pixel size:Pixel size:Pixel size:Pixel size:Pixel size: 45 by 450µmPeak responsivity:Peak responsivity:Peak responsivity:Peak responsivity:Peak responsivity: 1x106 V/wattSpectral response range:Spectral response range:Spectral response range:Spectral response range:Spectral response range: 1000 to 3000nmSpectral coverage:Spectral coverage:Spectral coverage:Spectral coverage:Spectral coverage: about 600nm in user
specified regionSpectral Resolution:Spectral Resolution:Spectral Resolution:Spectral Resolution:Spectral Resolution: 20nm with standard module
and slit option.Light entrance:Light entrance:Light entrance:Light entrance:Light entrance: Slit:Slit:Slit:Slit:Slit: 50µm to 400µm Fiber:Fiber:Fiber:Fiber:Fiber: SMA 905 fiber coupler
50µm to 600µm core diameterNA = 0.2
Grating:Grating:Grating:Grating:Grating: 75 to 1200 grooves per mmStray light rejection:Stray light rejection:Stray light rejection:Stray light rejection:Stray light rejection: better than 10-3
Analog to digital:Analog to digital:Analog to digital:Analog to digital:Analog to digital: 12-bit resolution,PCMCIA standard
Dynamic range:Dynamic range:Dynamic range:Dynamic range:Dynamic range: >1000:1 for single scanDimensions:Dimensions:Dimensions:Dimensions:Dimensions: 5” x 4” x 2.5” (LxWxH)Shutter:Shutter:Shutter:Shutter:Shutter: Built-inDetector cooling:Detector cooling:Detector cooling:Detector cooling:Detector cooling: -10°CWeight:Weight:Weight:Weight:Weight: 2 lbs.Software:Software:Software:Software:Software: SM32Pro
Ordering Information: Please indicate productnumber plus description when ordering.
SM301SM301SM301SM301SM301 PbS Array Spectrometer
�$��� ������ ����$����� ������
������
(������
�������� ����)��� �!%���
�� ����*
SM301 Optical Path
revised 6/03
SPECTRAL PRODUCTS
46Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
SM302 / SM302-EXSM302 / SM302-EXSM302 / SM302-EXSM302 / SM302-EXSM302 / SM302-EXInGaAs ArrInGaAs ArrInGaAs ArrInGaAs ArrInGaAs Arraaaaay Spectry Spectry Spectry Spectry Spectrometerometerometerometerometer
revised 8/03
• 0.9 to 1.7 µm or
0.9 to 2.6µm Extended
• Cooled Stable Operation
• Large Dynamic Range
• 16 bit Data Acquisition
• Low Noise
• Fiber Coupling Capability
The SM302 is a versatile, high performance, compact InGaAs array
spectrometer that consists of a low noise, 256-element, InGaAs array
detection module, a high precision tunable spectrograph optimized for the
spectral range of 0.9 to 1.7µm (0.9 to 2.6µm extended), a 16-bit data
acquisition board, and Windows® based operating software.
The dual grating capacity spectrometer comes preloaded with one grating
and slit tailored for high-resolution work throughout the usable range of the
detector. An optional second grating may be loaded to add wide coverage
capability, or both gratings may be user specified to achieve desired coverage
and resolution. Integrated filters allow the user to selectively block out
unwanted higher orders, and the standard dual function entrance can accept
light directly coupled through the built-in slit or from a standard NIR fiber.
The SM302 detector is a multiplexed InGaAs array that is thermoelectrically
cooled and temperature stabilized to ensure long-term operation stability. The
multichannel detection with a readout rate of 333 kHz or faster both reduces
measurement time and enhances signal-to-noise ratio.
Compact, TCompact, TCompact, TCompact, TCompact, Tunableunableunableunableunable, NIR Spectr, NIR Spectr, NIR Spectr, NIR Spectr, NIR Spectrometerometerometerometerometer
SPECTRAL PRODUCTS
47Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
revised 6/03
Ordering Information: Please indicate productnumber plus description when ordering.
SM302SM302SM302SM302SM302 InGaAs Array SpectrometerSM302-EXSM302-EXSM302-EXSM302-EXSM302-EX Extended range InGaAs Array Spectrometer
Spectrograph:Spectrograph:Spectrograph:Spectrograph:Spectrograph:Resolution:Resolution:Resolution:Resolution:Resolution: <2nm with standard configurationLight entrance:Light entrance:Light entrance:Light entrance:Light entrance: Dual SMA/ 50µm slit standard.Other slit or fiber connections options availableAvailable slit sizes:Available slit sizes:Available slit sizes:Available slit sizes:Available slit sizes: 50µm standard. 100µm,
0.125mm, 0.150mm, 0.3mm, 0.6mm,1.2mm, and 2.4mm, available.
f#:f#:f#:f#:f#: 3.9Grating:Grating:Grating:Grating:Grating: One 600 groove grating included.Additional gratings available upon requestGrating control:Grating control:Grating control:Grating control:Grating control: RS232Filtering:Filtering:Filtering:Filtering:Filtering: Permanent 0.9 µm low blocking filterincluded. 1.3 µm low blocking flip-filter included inextended model.Dimensions:Dimensions:Dimensions:Dimensions:Dimensions: 10.5” x 5” x 4” (LxWxH)WWWWWeight:eight:eight:eight:eight: 6.5 lb.Software:Software:Software:Software:Software: Windows control program and
LabVIEW. drivers included.
StandardStandardStandardStandardStandard ExtendedExtendedExtendedExtendedExtended
DetectorDetectorDetectorDetectorDetector Hamamatsu InGaAs Array
RangeRangeRangeRangeRange 0.9 to 1.7 µm 0.9 to 2.55 µm
Number of pixelsNumber of pixelsNumber of pixelsNumber of pixelsNumber of pixels 256
Pixel sizePixel sizePixel sizePixel sizePixel size 50 by 250µm
Bad PixelsBad PixelsBad PixelsBad PixelsBad Pixels 2% max 5% max
PPPPPeak sensitivityeak sensitivityeak sensitivityeak sensitivityeak sensitivity 1.55µm 2.3µm
PPPPPeak reak reak reak reak responsivityesponsivityesponsivityesponsivityesponsivity 0.95 A/W 1.1 A/W
Dynamic rangeDynamic rangeDynamic rangeDynamic rangeDynamic range 10,000:1 8,000:1
Analog to digitalAnalog to digitalAnalog to digitalAnalog to digitalAnalog to digital 16-bit PCI interface, 333 kHz
Integration TimeIntegration TimeIntegration TimeIntegration TimeIntegration Time Min: 5ms Max: 10s
CoolingCoolingCoolingCoolingCooling -10°C one stage TE -20°C two stage TE
Dark CurrentDark CurrentDark CurrentDark CurrentDark Current 0.1 pA typ. 1000 pA typ.
Noise mV rmsNoise mV rmsNoise mV rmsNoise mV rmsNoise mV rms 0.15 0.18
MaximumMaximumMaximumMaximumMaximum
non-uniformity non-uniformity non-uniformity non-uniformity non-uniformity ± 5% max ± 10% max
Detector SpecificationsDetector SpecificationsDetector SpecificationsDetector SpecificationsDetector Specifications
GratingGratingGratingGratingGrating BandwidthBandwidthBandwidthBandwidthBandwidth ResolutionResolutionResolutionResolutionResolution
groove/mmgroove/mmgroove/mmgroove/mmgroove/mm PPPPPeak (nm)eak (nm)eak (nm)eak (nm)eak (nm) (nm)(nm)(nm)(nm)(nm) (nm)(nm)(nm)(nm)(nm) StatusStatusStatusStatusStatus
600 1200 126 <1 INCLUDED SM302
1600 113 INCLUDED SM302-EX
1850 97 special order
2500 70 special order
300 1200 280 <2 special order
1700 270 special order
2000 260 STOCK
2500 250 STOCK
150 1250 580 4 STOCK
2000 570 special order
2500 560 special order
75 1700 1170 8 STOCK
2000 1170 special order
2500 1160 special order
45 1750 1970 13 STOCK
SPECTRAL PRODUCTS
48Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
SM520SM520SM520SM520SM520ExtrExtrExtrExtrExtreme Resolution CCD Spectreme Resolution CCD Spectreme Resolution CCD Spectreme Resolution CCD Spectreme Resolution CCD Spectrometerometerometerometerometer
• Optical input direct to slit
or via fiber .
• Allows higher resolution spectral
measurements in up to a 700nm
measurement window between
200nm and 1050nm — double the
resolution of the SM200 and SM240.
• USB 2.0 interface with 16-bit
dynamic range available!
The SM520 is a CCD based spectrometer that offers more than double the
resolution of the SM240. This resolution is achieved using oversized (30mm x
30mm) optical-bench components. These components offer approximately 4
times the effective collimation, grating and focusing area than what is used in the
SM200 and SM240. As with all spectrometers, effective resolution increases
as window size decreases. A 100nm window will have approximately .09nm
resolution (as opposed to .3nm for the SM200 and SM240). A 700 nm window
will have approximately .56nm resolution (as opposed to 1.12 nm for the SM200
and SM240).
Standard interfaces include a USB 2.0 interface with 16-bit extended dynamic
range and a PCI card interface with 12-bit dynamic range. Custom interfaces and
legacy ISA and PCMCIA interfaces are also available. Software support includes a
SDK and DLLs for dedicated applications development and our SM32Pro windows
based spectral acquisition and analysis software. Both standard and legacy
interface designs provide support for advanced acquisition programming and
external triggering.
The Choice fThe Choice fThe Choice fThe Choice fThe Choice for Spectror Spectror Spectror Spectror Spectral Applicationsal Applicationsal Applicationsal Applicationsal Applications
revised 6/03
SPECTRAL PRODUCTS
49Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
revised 6/03
Ordering Information: Please indicate productnumber plus description when ordering.
SM520 USBSM520 USBSM520 USBSM520 USBSM520 USB USB interface, SpectrometerSM520 PCISM520 PCISM520 PCISM520 PCISM520 PCI PCI interface, Spectrometer
Specifications:Specifications:Specifications:Specifications:Specifications:Detectors:Detectors:Detectors:Detectors:Detectors:
Sony CCD Linear ArraySony CCD Linear ArraySony CCD Linear ArraySony CCD Linear ArraySony CCD Linear ArrayNumber of Pixels: 2048Sensing Pixel Size: 14µm x 200µmSensitivity: 1800 V/(lx•s) @ 660nmCustomer array installation availableCustomer array installation availableCustomer array installation availableCustomer array installation availableCustomer array installation available
Dimensions (inches):Dimensions (inches):Dimensions (inches):Dimensions (inches):Dimensions (inches): 7.0 h x 6.75 w x 3.0 dWeight:Weight:Weight:Weight:Weight: 4.0 lbs.Spectral Range:Spectral Range:Spectral Range:Spectral Range:Spectral Range: UV - 200nm to 450nm
VIS - 380nm to 760nmNIR - 550nm to 1050nm
other ranges are configurablefrom 200nm to 1050nm
Spectral Resolution:Spectral Resolution:Spectral Resolution:Spectral Resolution:Spectral Resolution: ~0.1nm, dependent onspectral range, slit width, and fiber diameter.
Entrance:Entrance:Entrance:Entrance:Entrance:FiberFiberFiberFiberFiber SMA 905 or FC fiber coupler.
50-600µm core Ø fiberNA = 0.2
SlitSlitSlitSlitSlit 10, 25, 50 or 100µmDynamic Range:Dynamic Range:Dynamic Range:Dynamic Range:Dynamic Range: 12 bit (4096:1) or
16 bit (65536:1)Computer Interface:Computer Interface:Computer Interface:Computer Interface:Computer Interface:
USB 2.0USB 2.0USB 2.0USB 2.0USB 2.0 16 bit 500KHzPCI busPCI busPCI busPCI busPCI bus NI-PCI 12 bit 200 KHz
PCI interface boardCall SP for other interface options,Call SP for other interface options,Call SP for other interface options,Call SP for other interface options,Call SP for other interface options,including PCMCIA and ISAincluding PCMCIA and ISAincluding PCMCIA and ISAincluding PCMCIA and ISAincluding PCMCIA and ISA
Temperature Range:Temperature Range:Temperature Range:Temperature Range:Temperature Range: 15°C to 40°CSoftware:Software:Software:Software:Software: SM32Pro
SoftwareSoftwareSoftwareSoftwareSoftware✓✓✓✓✓ SM32Pro - Windows® 98,2000, XP
based software for data acquisitionand analysis.
✓✓✓✓✓ Transmission, reflectance, and absorbancemeasurements.
✓✓✓✓✓ Data export, zoom in and out, spectrum overlays, and many more features.
✓✓✓✓✓ Color analysis tools included.✓✓✓✓✓ Signal average and integration time control.✓✓✓✓✓ Double beam version available.✓✓✓✓✓ SDK and DLLs available for easy custom
software development.
Software
SPECTRAL PRODUCTS
50Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
revised 6/03
SpectrSpectrSpectrSpectrSpectraM AaM AaM AaM AaM Accessoriesccessoriesccessoriesccessoriesccessories
AT200720AT200720AT200720AT200720AT200720 Filter for removing second orders for 200 to 720nm.
AT3501050AT3501050AT3501050AT3501050AT3501050 Filter for removing second orders for 350 to 1050nm.
AT-450AT-450AT-450AT-450AT-450 Reflectance attachment, built-in light source, 45° illuminating
and 0° viewing geometry for SM200, 220, and 240.
AT-COSAT-COSAT-COSAT-COSAT-COS Cosine Corrector for measurement of filtered off-angle light.
The fused silica dome shaped diffuser gives excellent
transmission in the visible region and adequate
transmission in the UV region.
AT-CRTAT-CRTAT-CRTAT-CRTAT-CRT CRT attachment for SM200 and 240.
AT-DIFAT-DIFAT-DIFAT-DIFAT-DIF Diffuser mounts directly to the SM Series spectrometers.
Offered with a ground quartz diffuser as standard, up to
3 - 0.5" Ø by 1.5mm thick ND filters can be added
to the assembly.
AT-IS-1.5AT-IS-1.5AT-IS-1.5AT-IS-1.5AT-IS-1.5 Stand alone or directly attachable Integrating sphere (1.5"sphere).
AT-UVEAT-UVEAT-UVEAT-UVEAT-UVE UV enhancement coating for detector array.
AT-IREAT-IREAT-IREAT-IREAT-IRE IR enhancement coating for detector array.
NI-xxxNI-xxxNI-xxxNI-xxxNI-xxx 100 KHz PCM(CIA), PCI or ISA data acquisition
board with cable.
SM500SM500SM500SM500SM500 Conversion box with cable for accepting NI- PCM(CIA),
PCI and ISA computer interfaces.
AT-DIF DiffuserAT-COS Cosine Corrector
SM2xx Spectrometer
AT-DIF
Adapter
AT-COS
AT-IS-1.5 Integrating Sphere
SPECTRAL PRODUCTS
51Copyright © 2003 Spectral LLC www.spectralproducts.com Toll Free 1-877-208-0245 [email protected]
Sp
ectrumA
nalyzersD
etectionSystem
sS
amp
ling
Accessories
Ap
pend
ixP
roduct IndexSpectrom
eterB
asics
Monochrom
atorsand Spectrographs
Fibers &
Coup
lersA
pp
lication
& Selection
Sp
ecto
rmete
rsA
uto
matic
Filter Wheels
Light
Sources
SM32Pro SoftwareSM32Pro SoftwareSM32Pro SoftwareSM32Pro SoftwareSM32Pro Software• Displays percent of reflectance.• Calculates XYZ, Yxy, L*a*b*, L*C*hº, ∆L*a*b*,
∆L*C*h*, ∆ELab and ∆ECMC
• Illuminant conditions A and D65.• CIE 2º and 10º standard observers.• View up to 6 reflectance traces on a single graph,
with multiple graphs tiled on a single screen.• Prints in color or black & white.• Offers easy custom wavelength calibration
function.• Control signal averages and integration time• Save color files, export color files, and print color
matching files.• Exports graph or data to other Windows™
software and to most DOS software.• Has rubber-band zoom and auto-peak find.• Features intuitive menu system and tool bars.• Includes comprehensive documentation• 16- and 32-bit Windows™ and DOS SDK software
developer libraries are available.
SpectraM 3.xSpectraM 3.xSpectraM 3.xSpectraM 3.xSpectraM 3.xGeneral-purpose data acquisition and processing
software for SM200, SM-210, SM-220 (b), and SM-240
units. SpectraM 3.x allows Reflectance,Transmission and
Absorbance measurements. Additionally CIE color values
such as X Y Z, and Lab, may be obtained-using A and D 65
illuminant conditions with the software package. Data may
be saved as a graph, or exported to ASCII text files for
import to spreadsheet applications for further analysis.
Graphing functions include zooming, basic text annotation,
and plot overlays on a single graph. Color values may be
compared to a user selectable standard in order to obtain
Delta values. Spectrometer calibration can be handled easily
through use of the software combined with a traceable light
source.
SpectraM-XLSpectraM-XLSpectraM-XLSpectraM-XLSpectraM-XLMicrosoft Excel macro supports SM 200, SM-210,
SM-220 (b), and SM-240 for data acquisition, graphics,
and data processing.
SpectraM SDKSpectraM SDKSpectraM SDKSpectraM SDKSpectraM SDK, 16 Bit & 32 BitAvailable for customers who wish to use SM hardware
with custom designed software. The SDKs are available in
16-bit and 32-bit formats, and include our dynamic linked
libraries in addition to several various code samples on how
to use the functions the DLLs contain. A manual that details
the functions available is also included.
revised 6/03