special order product

16
BD LSRFortessa X-20 Special Order Product Designed for limited space and boundless potential

Upload: others

Post on 10-Nov-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Special Order Product

BD LSRFortessa™ X-20Special Order Product

Designed for limited space and boundless potential

Page 2: Special Order Product
Page 3: Special Order Product

The BD LSRFortessa™ X-20 cell analyzer delivers high performance, multicolor analysis with the most compact footprint in its class at just 30 x 29 in. (76.2 X 73.7 cm) and a height of just 30 in. (76.2 cm).

The BD LSRFortessa X-20 can be configured with up to 5 lasers, which enables the detection of up to 20 parameters simultaneously. The most common laser choices are blue, red, violet, yellow-green, and UV. Additional laser choices are available and may be configured at the time of purchase or at a later date to meet evolving application requirements.

Next generation high performance cell analyzer

The BD LSRFortessa X-20 is supported by a full range of BD Biosciences reagents, including the latest BD Horizon™ Brilliant Violet™ polymer conjugates, which offer superior brightness and are optimized for use on the BD LSRFortessa X-20.

The BD LSRFortessa X-20 cell analyzer is the latest in the line of high-performance instrumentation from BD Biosciences.

Based on the industry-leading BD LSRFortessa™ analyzer, the BD LSRFortessa X-20 integrates the newest laser and light technologies, in a greatly reduced footprint. The BD LSRFortessa X-20 retains the flexibility to support the expanding needs of multicolor flow cytometry assays.

Page 4: Special Order Product

4

The BD LSRFortessa X-20 is designed to support your current assay requirements. In addition, as future needs arise, optical capability can be added or upgraded.

Flexibility in a small spaceThe BD LSRFortessa X-20 fits most flow cytometry analyzer needs, and can be ordered with up to 5 lasers—most commonly, blue, red, violet, yellow-green, and UV—which provides flexibility in laser wavelengths. This allows researchers to optimize assay design by selecting the latest fluorescent dyes and antibodies in experimental protocols. The instrument can accommodate the detection of up to 18 colors simultaneously with a defined set of optical filters that meet today’s assay requirements.

A compact footprint and height (30 x 29 x 30 in. or 76.2 x 73.7 x 76.2 cm) allow the BD LSRFortessa X-20 to fit easily on the benchtop for the cost-effective use of valuable laboratory space. In addition to the reduced size, design enhancements provide easier access to bandpass filters and mirrors, simplifying changes in the instrument configuration.

To improve experimental workflow, the optional BD™ High Throughput Sampler (HTS) provides rapid, fully automated sample acquisition from microtiter plates. In high-throughput mode, the HTS option can speed through a 96-well plate in less than 15 minutes with less than 0.5% sample carryover from one well to the next. Low carryover is essential to ensure data quality in research applications.

The most compact footprint in its classPerformance without peer, choice without compromise

Page 5: Special Order Product

b d l s r f o r t e s s a x - 2 0

5

Emission spectraExcitation laser line (nm) Fluorescence channel Fluorochromes provided by BD Biosciences488 Green FITC Alexa Fluor® 488

Yellow PE PI

Orange BD Horizon™ PE-CF594 PE-Texas Red®

Red 7-AAD PE-Cy™5 PerCP PerCP-Cy™5.5

Infrared PE-Cy™7

532b or 561b Yellow PE PI

Orange BD Horizon PE-CF594 PE-Texas Red®

Red PE-Cy5

Infrared PE-Cy7

640 Red APC Alexa Fluor® 647

Far Red Alexa Fluor® 700

Infrared BD APC-H7 APC-Cy™7

405 Blue BD Horizon™ BV421 BD Horizon™ V450 BD Horizon™ VPD450 Pacific Blue™

Green BD Horizon™ V500 AmCyan

Orange BD Horizon™ BV605

355 Blue Hoechst 33342

Page 6: Special Order Product

o p t i c s

6

Maximum signal, minimum crosstalk

The patented collection optics are arranged in polygon-shaped optical pathways. Their novel design efficiently maximizes signal detection and increases sensitivity and resolution. This enables researchers to identify cells with especially dim expression, or quantitate rare cell populations, by optimizing multicolor assays and panel design for best results.

Optics systemThe optics system uses a novel laser design that illuminates cells in the sample, and collection optics that direct light scatter and fluorescence signals through spectral filters to the detectors. Innovative designs for both the excitation optics and collection optics in BD LSRFortessa X-20 systems minimize light loss and optimize collection efficiency for increased sensitivity and resolution.

Excitation optics The excitation optics include a laser array which consists of multiple (up to five) fixed wavelength lasers, beam-shaping optics, and individual pinholes which together produce spatially separated beam spots.

A final lens focuses the laser light into the gel-coupled cuvette flow cell. Since the optical pathway and the sample core stream are in a fixed position, alignment is constant from day to day and from experiment to experiment.

An innovative and proven platformfor multicolor analysis

Optimal resolution of cell populationsThe high sensitivity of the BD LSRFortessa X-20 allows for optimal resolution of lower expression antigens and rare cell subsets. In this example, regulatory T cells (Tregs), characterized by low levels of expression of CD127 and high levels of CD25, were easily identified. Note the resolution of different levels of expression of CD25 and CD127.

All Events

lymphocytes

FSC-A

SSC

-A(x

1,0

00)

(x 1,000)

250

250

200

150

100

50

20015010050

Page 7: Special Order Product

o p t i c s

7

Collection optics Emitted light from the gel-coupled cuvette is delivered by fiber optics to the detector arrays. The polygonal optical pathways maximize signal detection from each laser illuminated beam spot. Bandpass filters in front of each PMT collect selected fluorophore spectral wavelengths. This arrangement allows filter and mirror changes within the optical array to be made easily and requires no additional alignment.

This design efficiently exploits the principle that light reflection is more efficient than light transmission for fluorescence signal detection. Emitted light travels to each PMT detector via reflection and is transmitted through only two pieces of glass to reach the detector. Therefore, more colors and higher panel multiplexing can be achieved with minimum light loss.

lymphocytes

CD3+

CD3 PerCP-Cy5-5-A

SSC

-A(x

1,0

00)

-221M 10

5

250

200

150

100

50

104

103

102

0-102

CD3++

CD4 APC-A

CD

25 P

E-A

-388M 10

5

105

104

103

102

0-7

6

104

103

102

-102

0

CD3+ CD4+

T regs

CD25 PE-A

CD

127

BV

421-

A

-76M 10

5

105

104

103

102

101

0

104

103

102

0

Page 8: Special Order Product

f l u i d i c s

8

Characterization of instrument sensitivity using 8-peak beadsThe sensitivity across detectors of a BD LSRFortessa X-20 equipped with blue (50-mW), red (100-mW), and violet (50-mW) lasers is illustrated by the optimal resolution of SPHERO™ Rainbow 8-peak beads. Note that all peaks are easily identified in various detectors from the blue (A,B), red (C,D), or violet (E,F) lasers.

Superior performance

While improved laser and optical detection design features have been incorporated into the BD LSRFortessa X-20, the fluidics system retains the true fixed-alignment flow cell design. The flow cell is gel-coupled to the collection optics to maximize detector signal.

Fluidics systemThe fluidics system is pressure driven. Hydrodynamic focusing forces sample cells through the cuvette flow cell, where they are interrogated. The flow cell is in fixed alignment with the laser and gel-coupled to the collection optics. This design ensures that the laser is precisely focused on the sample stream and the maximum amount of emitted light can be collected for added sensitivity in multicolor applications. Fixed alignment also minimizes startup time, improves experiment-to-experiment reproducibility, and enables automated daily quality control (QC).

The sheath container (8 L) and waste container (10 L) are outside the cytometer, positioned on the floor for easy access.

Fluidics sensors maintain constant pressure, while a fluidics monitoring system warns when sheath fluid is low or empty, or when the waste container is full.

Unique and revolutionary designsfor multicolor analysis

A

B

Coun

t

FITC-A

150

100

50

0-126 102 103 104 105

0Co

unt

PE-A

150

100

50

0-226 102 103 104 105

0

-102

Page 9: Special Order Product

9

X-mount optical plate

C E

D F

Coun

t

APC-A

100

7550

0-71 102 103 104 105

025

Coun

t

BD Horizon BV421-A

150

100

50

0-113 102 103 104 105

0

Coun

t

APC-H7-A

8070

10

0-155 102 103 104 105

060

5040

3020

Coun

t

BD Horizon BV605-A

125

100

25

0-90 102 103 104 105

075

50

Page 10: Special Order Product

10

Analysis of human T-cell subsetsData shows a 10-color panel run on a 3-laser BD LSRFortessa X-20 with a blue/red/violet configuration. The panel was used for defining various subsets of regulatory T cells (A, B), memory/effector CD4+ T cells (C, D, E, F), and memory/effector CD8+ T cells (G, H, I, J).

Greater consistency

BD FACSDiva™ software controls the efficient setup, acquisition, and analysis of flow cytometry data from the BD LSRFortessa X-20 workstation. The software is common across BD FACS™ instrument platforms, including the BD FACSCanto™ cell analyzer and BD FACSAria™ cell sorter systems. This affords researchers greater application flexibility, allowing them to easily move assays from one platform to another.

Cytometer setup and tracking The BD™ Cytometer Setup and Tracking (CS&T) feature of BD FACSDiva software establishes baseline settings and adjusts for instrument variability. The software reduces operator error, and ensures consistency of results by setting the signal time delay across the multiple laser beams and optimizing PMT voltages. Application-specific settings can also be specified, allowing for rapid setup and performance of routine experiments in a more consistent manner. QC tracking capabilities in the software measure instrument settings and report on performance. Levey-Jennings plots help users understand instrument performance and identify maintenance issues.

Acquisition and analysisBD FACSDiva software enables researchers to preview and record data from multiple samples with an automated acquisition process. Acquisition templates, user-defined experiment layouts, and simple compensation procedures are also managed by the software to further facilitate acquisition.

Automated controls for setup,acquisition, and analysis

BD LSRFortessa X-20 front panel

All Events

FSC-A (x 1,000)

SSC

-A(x

1,0

00)

250

250

200100 15050

200

150

100

50

All Events

CD3 V500-A

CD3+

M

SSC

-A(x

1,0

00)

250

0-58

102 103 104 105

200

150

100

50

CD8+

CD3+

CD4+

CD4 APC-H7-AM

CD

8 Pe

rCP-

Cy5

-5-A 10

5

0-807

-864

103 104 105

104

103

0

All Events

FSC-A (x 1,000)

SSC

-A(x

1,0

00)

250

250

200100 15050

200

150

100

50

All Events

CD3 V500-A

CD3+

M

SSC

-A(x

1,0

00)

250

0-58

102 103 104 105

200

150

100

50

CD8+

CD3+

CD4+

CD4 APC-H7-AM

CD

8 Pe

rCP-

Cy5

-5-A 10

5

0-807

-864

103 104 105

104

103

0

All Events

FSC-A (x 1,000)

SSC

-A(x

1,0

00)

250

250

200100 15050

200

150

100

50

All Events

CD3 V500-A

CD3+

M

SSC

-A(x

1,0

00)

250

0-58

102 103 104 105

200

150

100

50

CD8+

CD3+

CD4+

CD4 APC-H7-AM

CD

8 Pe

rCP-

Cy5

-5-A 10

5

0-807

-864

103 104 105

104

103

0

Plots A–B

Plots C–F

Plots G–J

Page 11: Special Order Product

b d f a c s d i va

11

CD8+

CD45RO PE-Cy7-A

M

CD

45R

A F

ITC

-A

105

0-974

103 104 105

104

103

102

101

0

CD8+

CCR7 APC-A

M

CD

45R

O P

E-C

y7-A

105

0-472

-807

103 104 105

104

103

0

CD8+

CD28 PE-CF594-A

M

CD

45R

O P

E-C

y7-A

105

0-185

-807

103 104 105102

104

103

0

CD8+

CD28 PE-CF594-A

M

CD

127

BV

421-

A

105

0-185

-14

103 104 105102

104

103

0

CD4+

CD45RO PE-Cy7-A

M

CD

45R

A F

ITC

-A

105

0-304

-14

103 104 105

104

103

102

101

CD4+

CD4+ CD127 low CD25 high

CD25 PE-A

M

CD

127

BV

421-

A

105

0-304

-14

103102 104 105

104

103

102

0

CD4+ CD127 low CD25 high

CD45RO PE-Cy7-A

M

Co

un

t45

0-304

103 104 105

4035

3025

2015

105

0

CD4+

CCR7 APC-A

M

CD

45R

O P

E-C

y7-A

105

102-58

-304

0 103 104 105

104

103

0

CD4+

CD127 BV421-A

M

CD

27 A

lexa

Flu

or®

700 10

5

-14

-221

0 103 104 105102

104

103

103

0

CD4+

CD27 Alexa Fluor® 700-A

M

CD

28 P

E-C

F594

-A

105

0-221

-185

103 104 105102

104

103

102

0

For analysis, the software includes powerful features such as hierarchical snap-to gating, a variety of plot formats, and batch analysis. Recorded data can be analyzed by creating plots, gates, population hierarchies, and statistics views on a BD FACSDiva global worksheet. Once the global worksheet is saved, it can be used to analyze multiple sample tubes from an experiment, thereby saving time.

Numerous other productivity benefits include user-defined batch analysis and automated features such as gate resizing, pausing between data files, exporting statistics, and printing before proceeding to the next data file.

G H I J

C D E F

A B

Page 12: Special Order Product

c u s t o m

12

Analysis of human lymphocyte subsetsData shows a 10-color panel run on a 3-laser BD LSRFortessa X-20 with a blue/red/violet configuration. The panel was used for defining various lymphocyte T-cell subsets (A–E, this page) and non–T-cell subsets (F–J, opposite page) using lysed whole blood (BD FACS™ lysing solution) from a normal donor.

The innovative special order program is tailored to meet the special needs of research at the leading edge of biomedical discovery, and offers a wide range of choices to help researchers create the ultimate customized instrument for their requirements.

Multiple power optionsInnovative laser options include the choice of solid-state lasers across the full spectrum. Currently, a menu of 18 laser wavelength options is offered, ranging from the complete spectrum of ultraviolet to infrared wavelengths. Through the special order program, researchers can configure a BD LSRFortessa X-20 with up to 5 lasers and 20 positional choices for the detectors. In addition to laser wavelength, the special order program offers multiple laser power options and filter selections to better optimize assay needs.

Special order products for unique needsChoice now and in the future

CD3-

CD20 APC-H7-A

CD

19 P

E-C

F594

-A10

5

-472

-807

M -102 103 104 105

104

103

0

0

CD3-

CD16 PE-Cy7-A

CD

19 P

E-C

F594

-A10

5

-472

-807

M -102 103 104 105

104

103

0

0

CD3-

CD16 PE-Cy7-A

CD

56 A

PC-A

105

-472

-139

M -102 103 104 105

104

103

0

0

CD3-

CD8 Alexa Fluor® 700-A

CD

7 PE

-A10

5

-304

-155

M -102 103 104 105

104

103

102

0

0 102

CD3-

CD56 APC-A

CD

8 A

lexa

Flu

or®

700

-A10

5

-139

-304

M 103 104 105

104

103

102

-102 0

0 102

CD3-

CD20 APC-H7-A

CD

19 P

E-C

F594

-A10

5

-472

-807

M -102 103 104 105

104

103

0

0

CD3-

CD16 PE-Cy7-A

CD

19 P

E-C

F594

-A10

5

-472

-807

M -102 103 104 105

104

103

0

0

CD3-

CD16 PE-Cy7-A

CD

56 A

PC-A

105

-472

-139

M -102 103 104 105

104

103

0

0

CD3-

CD8 Alexa Fluor® 700-A

CD

7 PE

-A10

5

-304

-155

M -102 103 104 105

104

103

102

0

0 102

CD3-

CD56 APC-A

CD

8 A

lexa

Flu

or®

700

-A10

5

-139

-304

M 103 104 105

104

103

102

-102 0

0 102

A

D E

B C

Plots A–E

Page 13: Special Order Product

c u s t o m c o n f i g u r at i o n

13

CD3+

CD4 V450-A

CD

8 A

lexa

Flu

or®

700

-A10

5

-78

-304

M 102 103 104 105

104

103

102

-102 0

0

CD3+

CD56 APC-A

CD

8 A

lexa

Flu

or®

700

-A10

5

-472

-304

M -102 103 104 105

104

103

102

-102 0

00

CD3+

CD57 FITC-A

CD

7 PE

-A10

5

-124

-155

M 102 103 104 105

104

103

102

0

0

CD3+

CD57 FITC-A

CD

8 A

lexa

Flu

or®

700

-A10

5

-124

-304

M 102 103 104 105

104

103

102

-102 0

0

CD3+

CD8 Alexa Fluor® 700-A

CD

7 PE

-A10

5

-304

-155

M 102 103 104 105

104

103

102

0

0-102

CD3+

CD4 V450-A

CD

8 A

lexa

Flu

or®

700

-A10

5

-78

-304

M 102 103 104 105

104

103

102

-102 0

0

CD3+

CD56 APC-A

CD

8 A

lexa

Flu

or®

700

-A10

5

-472

-304

M -102 103 104 105

104

103

102

-102 0

00

CD3+

CD57 FITC-A

CD

7 PE

-A10

5

-124

-155

M 102 103 104 105

104

103

102

0

0

CD3+

CD57 FITC-A

CD

8 A

lexa

Flu

or®

700

-A10

5

-124

-304

M 102 103 104 105

104

103

102

-102 0

0

CD3+

CD8 Alexa Fluor® 700-A

CD

7 PE

-A10

5

-304

-155

M 102 103 104 105

104

103

102

0

0-102

Evolving capabilitiesThe BD special order program allows customers to add lasers after their initial system purchase, to meet new or evolving requirements. This wide range of choice and flexibility makes the special order BD LSRFortessa X-20 a solid, long term investment.

An innovation processThe vigorous sourcing of the latest and best laser tech-nologies ensures an unparalleled range of configuration choices offered by the BD special order program for BD™ LSR analyzers. New technologies are regularly incorporated into the product line as soon as they become available.

The ever-expanding list of available lasers demonstrates BD’s ongoing commitment to perpetual innovation. This is one of the many ways BD ensures that the BD LSR analyzer platform continues to support the evolving needs of leading researchers around the world.

Cuvette flow cell

F

I J

G HAll Events

CD45+

CD45 V500-A

SSC

-A(x

1,0

00)

250

200

150

100

50

-109M 0 102 103 104 105

CD45+

CD3- CD3+

CD3 PerCP-Cy5-5-A

SSC

-A(x

1,0

00)

250

200

150

100

50

-723M 0 102 103 104 105

All Events

CD45+

CD45 V500-A

SSC

-A(x

1,0

00)

250

200

150

100

50

-109M 0 102 103 104 105

CD45+

CD3- CD3+

CD3 PerCP-Cy5-5-A

SSC

-A(x

1,0

00)

250

200

150

100

50

-723M 0 102 103 104 105

Plots F–J

Page 14: Special Order Product

S E R V I C E S

14

BD Biosciences is fully committed to the success and satisfaction of its customers. Supporting flow cytometry applications for over 35 years, BD has training, technical application support, and field service teams dedicated to helping customers achieve optimal instrument performance, ease of use, and streamlined workflow. With unmatched flow cytometry experience, this world-class service organization is available to help with your BD LSRFortessa X-20 product installation, future upgrades, and application support.

Training Hands-on training is included with each special order BD LSRFortessa X-20 analyzer. Courses are held at BD training centers worldwide. BD flow cytometry training courses combine theory and practice to provide participants with the skills and experience they need to take full advantage of the capabilities of their BD LSRFortessa X-20 analyzer.

Technical application support BD technical application support specialists are available to provide field- or phone-based assistance and advice. Expert in all aspects of flow cytometry, BD technical application specialists are well equipped to address customer needs in both instrument and application support.

Field service When instrument installation or service is required, a BD Technical Field Service Engineer can be dispatched to the customer site. BD field service engineers are located across the world. On-site service and maintenance agree-ments are available to provide long-term support for BD LSRFortessa X-20 analyzers.

Special order programInstruments can be customized to meet customer requirements via the special order program.

Services

Page 15: Special Order Product
Page 16: Special Order Product

23-14841-00

BD Biosciences Regional Offices

Office locations are available on our websites.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.

Class 1 Laser Product.

APC-Cy™7: US Patent 5,714,386

Alexa Fluor® and Texas Red® are registered trademarks and Pacific Blue™ is a trademark of Life Technologies Corporation.

CF is a trademark of Biotium, Inc.

Cy is a trademark of Amersham Biosciences Corp.

SPHERO is a trademark of Spherotech, Inc.

Purchase does not include or carry any right to resell or transfer this product either as a stand-alone product or as a component of another product. Any use of this product other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited. Product availability and prices are subject to change without notice.

© 2013 Becton, Dickinson and Company. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in retrieval systems, or translated into any language or computer language, in any form or by any means: electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without prior written permission from BD Biosciences.

BD, BD Logo and all other trademarks are property of Becton, Dickinson and Company. © 2013 BD

AustraliaToll Free 1800 656 100Tel 61.2.8875.7000Fax 61.2.8875.7200bdbiosciences.com/anz

CanadaTel 866.979.9408Fax 888.229.9918 bdbiosciences.com/ca

ChinaTel 86.21.3210.4610Fax 86.21.5292.5191bdbiosciences.com/cn

EuropeTel 32.2.400.98.95Fax 32.2.401.70.94 bdbiosciences.com/eu

IndiaTel 91.124.2383566Fax 91.124.2383224/25/26bdbiosciences.com/in

JapanNippon Becton DickinsonToll Free 0120.8555.90Fax 81.24.593.3281bd.com/jp

Latin America/CaribbeanTel 55.11.5185.9995Fax 55.11.5185.9895bdbiosciences.com/br

New ZealandToll Free 0800 572.468 Tel 64.9.574.2468Fax 64.9.574.2469bdbiosciences.com/anz

SingaporeTel 65.6861.0633Fax 65.6860.1593bdbiosciences.com/sg

United StatesUS Orders 855.236.2772Technical Service 877.232.8995Fax 800.325.9637bdbiosciences.com