Spec Sheet
W50Pump
The CryoVation W50 isa liquid transferpumpfittedwithoperatingcontrols.Theunitisdesignedtoreceiveliquidcarbondioxide(CO2)ornitrousoxide (N20) at an inlet pressure of about 300PSIG(17.6kg/cm2),anddeliveritintoportablecylinders at a regulatedpressure ranging fromabout 400 PSIG (28.2 kg/cm2) to 900 PSIG(63.3 kg/cm2).
For filling of conventional industrial cylindersa fill manifold and scale(s) are required. Thisequipmentissoldseparately.ContactCryoVationfor various models available, ranging frommanuallyoperatedtofullyautomated.
Features ___________________________________________
• Pump–Single-stage,single-acting transferpumpwithautomaticsafetybypassvalve.Theunit isintended for handling liquid carbon dioxide and nitrous oxide, when properly cleaned for “OxygenService”andlubricatedwith“Halocarbon”oil,forliquidnitrousoxide.
• Drive -71/2horsepower,totallyenclosed,fancooledmotordrivesthepumpthroughapulleyandtripleV-beltcombination.Thedataplateonthemotorwillidentifyvoltagerequirementsandspecialcharacteristics.
• Automatic Bypass Valve-Thisvalveservestorelievethesystempressurewhendischargeflowhasbeenstoppedorexceeds1000psi(70kg/cm2).Bypassliquidisreturnedtotheliquidsupplyvessel.
• Pressure Gauge -Thisliquid-filledgaugeindicatesdeliverypressureatthedischargeofthepump.
• Relief Valve - A relief valve is installed in thedischarge line to protect the pump from possibleover-pressurization.
TechnicalSpecifications:
Fluid: LCO2 & LN2OFlow Rate: 50 Lb./Min (22 kg/Min.)Inlet PSI/Min: 290 PSIG (20.4 kg/cm2)Discharge PSI: 1,000PSIG(70.4kg/cm) AdjustablemaximumPump Speed: 452 RPMMotor: 7.5HP,TEFCPump Style: ReciprocatingVoltage: 240/480V,3-phase,60HzBore: 1.625”Stroke: 1.75”Weight: -
CryoVation | 609.914.4792 [email protected] | CryoVation.com | TheCryoShop.com
W50Pump
Spec Sheet
CryoVation | 609.914.4792 [email protected] | CryoVation.com | TheCryoShop.com
W50Pump
Each pumpmanufactured by CryoVation ismechanically andcryogenicallytestedpriortoshipmenttoensurethatperformancemeets customer specifications. The precision of measuringdevicesprovidesessential results: differential head, flow rate,seal gas consumption, pump efficiency, NPSH, noise andvibrationlevels-alldocumentedandsubmittedtothecustomer.
___________Oil Type:CarbonDioxide SAE30motoroil,non-detergentNitrousOxide KrytoxOil,p/n6353-5270Oil Fill: Tocenterlineofsightglass