spe 56487 analysis and interpretation of well test performance at arun field, indonesia authors: t....

43
SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil (Indonesia) T.A. Blasingame, Texas A&M U.

Post on 21-Dec-2015

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

SPE 56487

Analysis and Interpretation ofWell Test Performance at Arun Field, Indonesia

Authors:T. Marhaendrajana, Texas A&M U.

N.J. Kaczorowski, ExxonMobil (Indonesia)T.A. Blasingame, Texas A&M U.

Page 2: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Summary

A comprehensive field case history of the analysis and interpretation of well test data from the Arun Gas Field (Sumatra, Indonesia).

2-zone radial composite reservoir model is effective for diagnosing the effects of conden-sate banking at Arun Field.

Page 3: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Summary

Development and application of a new solution for the analysis and interpretation for wells that exhibit "well interference" effects.

Page 4: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Outline

Introduction Well Test Analysis Strategy Multiwell Model Regional Pressure Decline Analysis Procedure Field Example Conclusions

Page 5: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Ø

Ø

Ø

Ø

Ø

Ø

Ø

Ø

Ø

Ø

Ø

Arun FieldLocated in Northern part of

Sumatra, IndonesiaRetrograde gas reservoirOne of the largest gas fields in the

worldArun Field has 111 wells:

79 producers 11 injectors 4 observation wells 17 wells have been abandoned

Field Description

Page 6: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Major Phenomena in Arun

Liquid accumulation near wellbore (conden-sate banking) Need to know radial extent of condensate banking

for the purpose of well stimulation.

Well interference effect This well interference effect tends to obscure the

radial flow response, and hence, influence our analysis and interpretation efforts.

Page 7: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Well Test Analysis Strategy

Condensate banking phenomenon 2-zone radial composite reservoir model is used, where

the inner zone represents the "condensate bank," and the outer zone represents the "dry gas reservoir." (Raghavan, et al, (1995) and then by Yadavalli and Jones (1996) )

Well interference effect Developed a new method for the analysis of well test

data from a well in multiwell reservoir where we treat the "well interference" effect as a "Regional Pressure Decline."

Page 8: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Multiwell Model

Bounded Reservoirwith Multiple Wells

pD(xD,yD,tDA) = qD,iu(tDA – tsDA,i)i = 1

nwell

pD,i(xD,yD,[tDA – tsDA,i],xwD,i,ywD,i)

Page 9: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Analytical Solution Matches Numerical Solution

10-1

100

101

102

103

Dim

en

sio

nle

ss

Pre

ss

ure

, pD

10-6

10-5

10-4

10-3

10-2

10-1

100

101

Dimensionless Time, tDA (Based on Drainage Area)

Legend:

Numerical SimulationAnalytical Solution

pD

pD'

Page 10: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Regional Pressure Decline Model

Arun Field has been produced for over 20 years and currently in "blowdown" mode.

Drawdown and buildup tests induce local transient effects.

Most of the well tests performed at Arun Field are relatively short (< 5 hours producing time), and the pseudosteady-state flow condition is not established in the area of investigation given such short produc-tion times.

Issues:

Page 11: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Regional Pressure Decline Model

All of the wells in the reservoir are at pseudosteady-state flow conditions at the time the "focus" well is shut-in.

Any rate change at the focus well (including a drawdown/buildup sequence) cause transient flow conditions only in the vicinity of the focus well–not in the entire reservoir.

Assumptions:

Page 12: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Regional Pressure Decline Model

Pressure at focus well:

pwD(tDA) = pD,1([xwD,1 + ],[ywD,1 + ],tDA,xwD,1,ywD,1)

+ 2tDA(D – 1)

D =Vpct

q1Bdpdt

=Vpct

q1Bwhere:

Page 13: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Regional Pressure Decline Model

Pressure buildup analysis relations:

psD(tDA) + 2(D – 1)tDA = 12

ln 4etDAe

Arw

2+ s

Vs.

Straight line on semilog plot

Page 14: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Regional Pressure Decline Model

Pressure buildup analysis relations:

Vs.

Straight line on Cartesian plot

tDAedpsD

dtDAe= 1

2– 2 (D – 1)

tDA2

tDAe

Page 15: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Simulated CaseR

ate,

q

Time, t

Offset wells are producedat the same flowrate.

Focus well is shut-in

Focus well is put on production

Focus well is shut-in

Offset wells are kepton production.

Page 16: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Multiwell Response is Different than Single Well Response

-2.0

-1.8

-1.5

-1.3

-1.0

-0.8

-0.5

-0.3

0.0

0.3

0.5

psD

', [p

ws-p

wf(t=

0)]

fo

rma

t

40x10-3

3020100

tDA

Legend:

Multiwell, Single Well

, tpDA=1x10-2

, tpDA=1x10-3

, tpDA=1x10-4

, tpDA=1x10-5

p sD' [

p ws

- p w

f(t=

0)]

form

at

tDA

Pressure builds up to pbar

(closed boundary)

pbar continues to decline.

Page 17: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Straight Line on Cartesian Plot

-2.00

-1.75

-1.50

-1.25

-1.00

-0.75

-0.50

-0.25

0.00

0.25

0.50

0.75

1.00

psD

e',

[pw

s-p

wf(t=

0)]

form

at

40x10-3

3020100

tDA

2/tDAe

Legend:

tpDA=1x10-2

tpDA=1x10-3

tpDA=1x10-4

tpDA=1x10-5

psDe' = 0.5psDe' = 0.5 - 2(D - 1) tDA

2/ tDAe

p sD

e' [

p ws

- p w

f(t=

0)]

form

at

tDA2/ tDAe

Page 18: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Regional Pressure Decline Signature May Not Be Unique

-5

-4

-3

-2

-1

0

1

psD

e',

[pw

s-p

wf(t=

0)]

fo

rma

t

10-5

10-4

10-3

10-2

10-1

100

101

102

tDA

2/tDAe

Legend:

tpDA=1x10-2

tpDA=1x10-3

tpDA=1x10-4

tpDA=1x10-5

p sD

e' [

p ws

- p w

f(t=

0)]

form

at

psDe' = 0.5psDe' = 0.5 - 2(D - 1) tDA

2/ tDAe

This portion may be falselyinterpreted as regional pressure decline effect.

tDA2/ tDAe

Page 19: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Analysis Procedures for Multiwell Reservoirs

To analyze pressure buildup tests taken in multiwell systems, we recommend the following procedures:

Step 1: Plot te(dpws/dte) versus t2/te on a Carte-sian scale. From the straight-line trend we obtain the slope mc and intercept bc. We calculate permeability using the intercept term as:

k = 70.6qBb ch

Page 20: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Analysis Procedures for Multiwell Reservoirs

Step 2: The Horner plot [(pws+mct) versus log((tp+t)/t)] can also be used to estimate formation properties. From the straight-line trend observed on the Horner plot, we obtain the slope msl as well as the intercept term, (pws + mct) t=1hr.

s = 1.1513(pws +mc t)t=1hr – pwf,t = 0

msl

– 1.1513 logtp

tp+1+ log k

ctrw2

– 3.22751

And the skin factor is calculated using:

k = 162.6qBmslh

Permeability is estimated using:

Page 21: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Analysis Procedures for Multiwell Reservoirs

Step 3: In order to use standard single-well type curves for type curve matching, we must make the appropriate "corrections". These relations are:

Pressure function:

Pressure derivative function:

tedpws

dte cor

= tedpws

dte+ mc

t2

te

pws,cor = pws + mct

Page 22: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

10-1

100

101

102

103

Ps

eu

do

pre

ss

ure

Fu

nc

tio

ns

, ps

i

10-4

10-3

10-2

10-1

100

101

Effective Shut-in Pseudotime, tae, hrs

Well C-I-18 (A-096) [Test Date: 28 September 1992]

Condensate bankingregion.

Higher mobilityregion.

Closed boundary at 160 ft?(includes non-Darcy flow).

Pse

ud

opre

ssu

re F

unc

tion

s, p

si

Effective shut-in pseudotime, hrs

Infinite acting Reservoir Model(Does not include non-Darcy flow)

Improvement onpressure derivative.

Well C-I-18 (A-096)[Test Date: 28 September 1992]

Page 23: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

1160

1140

1120

1100

1080

1060

1040

1020

Sh

ut-

in P

se

ud

op

res

su

re, p

pw

s, p

sia

100

101

102

103

Horner Pseudotime, (ta+tpa)/ta (tpa=tp=1.56 hr), hr

Well C-I-18 (A-096) [Test Date: 28 September 1992]

Condensate bankingregion.

Higher mobilityregion.

Well C-I-18 (A-096)[Test Date: 28 September 1992]

Sh

ut-i

n P

seu

dop

ress

ure

, psi

a

Horner pseudotime, hrs (tp = 1.56 hr)

Page 24: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

1150

1149

1148

1147

1146

1145

1144

1143

1142

Sh

ut-

in P

seu

do

pre

ssu

re,

pp

ws, p

sia

1086420

dppws/dta, psi/hr

Well C-I-18 (A-096) [Test Date: 28 September 1992]

Well C-I-18 (A-096)[Test Date: 28 September 1992]

pp,bar = 1148.6 psia

Onset of boundarydominated flow.

"Transient flow"

Data deviate from the "Muskat line"--indicating an interference effect

from surrounding wells.

Shu

t-in

pse

udop

ress

ure,

psi

a

dppws/dta, psi/hr

Page 25: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

-15

-10

-5

0

5

10

15

(p

p')

t a

e, p

si

302520151050

ta

2/tae, hrs

Well C-I-18 (A-096) [Test Date: 28 September 1992]

Well C-I-18 (A-096)[Test Date: 28 September 1992](

p p')

tae,

psi

ta2/ tae

Page 26: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

100

101

102

103

Ps

eu

do

pre

ss

ure

Fu

nc

tio

ns

, p

si

10-4

10-3

10-2

10-1

100

101

Effective Shut-in Pseudotime, tae, hrs

Well C-IV-11 (A-084) [Test Date: 5 January 1992]

Closed boundary at 150 ft?(includes non-Darcy flow).

Ps

eud

op

res

su

re F

un

ctio

ns,

psi

Effective shut-in pseudotime, hrs

Infinite-acting Reservoir Model(Does not include non-Darcy flow)

Improvement onpressure derivative.

Example 3: Log-log Summary Plot

Well C-IV-11 (A-084) [Test Date: 5 January 1992]

Raw dataCorrected

Page 27: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

2100

2000

1900

1800

1700

1600

1500

1400

1300

1200

Sh

ut-

in P

seu

do

pre

ssu

re,

pp

ws, p

sia

100

101

102

103

Horner Pseudotime, ( ta+tpa)/ta (tpa=tp=1.62 hr), hr

Well C-IV-11 (A-084) [Test Date: 5 January 1992]S

hu

t-in

Ps

eud

op

res

su

re, p

sia

Horner pseudotime, hrs (tp = 1.62 hr)

Example 3: Horner (Semilog) Plot

Well C-IV-11 (A-084) [Test Date: 5 January 1992]

Raw dataCorrected

Page 28: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

1922

1920

1918

1916

1914

1912

1910

Sh

ut-

in P

seu

do

pre

ssu

re,

pp

ws, p

sia

20151050

dppws/dta, psi/hr

Well C-IV-11 (A-084) [Test Date: 5 January 1992]

Sh

ut-

in p

seu

do

pre

ss

ure

, psi

a

dppws/dta, psi/hr

pp,bar = 1920 psia

Onset of boundarydominated flow.

"Transient flow"

Example 3: Muskat Plot (single well pavg plot)

Well C-IV-11 (A-084) [Test Date: 5 January 1992]

Page 29: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

25

20

15

10

5

0

-5

(p

p')

t a

e

2520151050

ta

2/tae, hrs

Well C-IV-11 (A-084) [Test Date: 5 January 1992](

pp')

ta

e, p

si

ta2/ tae

Example 3: "Well Interference" Plot (radial flow only)

Well C-IV-11 (A-084) [Test Date: 5 January 1992]

Intercept is used tocalculate permeability.

Slope is used in thepressure correction.

Presence of multiwellinterference effects is unclear

Page 30: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

100

101

102

103

Ps

eu

do

pre

ss

ure

Fu

nc

tio

ns

, p

si

10-4

10-3

10-2

10-1

100

101

Effective Shut-in Pseudotime, tae, hrs

Well C-IV-11 (A-084) [Test Date: 4 May 1992]

Condensate bankingregion.

Higher mobilityregion.

Closed boundary at 197 ft?(includes non-Darcy flow).

Improvement onpressure derivative.

Infinite-acting Reservoir Model(Does not include non-Darcy flow)

Ps

eud

op

res

su

re F

un

ctio

ns,

psi

Effective shut-in pseudotime, hrs

Example 4: Log-log Summary Plot

Well C-IV-11 (A-084) [Test Date: 4 May 1992]

Raw dataCorrected

Page 31: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

1950

1900

1850

1800

1750

1700

1650

1600

1550

1500

Sh

ut-

in P

seu

do

pre

ssu

re,

pp

ws, p

sia

100

101

102

103

Horner Pseudotime, ( ta+tpa)/ta (tpa=tp=1.63 hr), hr

Well C-IV-11 (A-084) [Test Date: 4 May 1992]

Condensate bankingregion.

Higher mobilityregion.

Sh

ut-

in P

seu

do

pre

ss

ure

, psi

a

Horner pseudotime, hrs (tp = 1.63 hr)

Example 4: Horner (Semilog) Plot

Well C-IV-11 (A-084) [Test Date: 4 May 1992]

Raw dataCorrected

Page 32: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

1884

1882

1880

1878

1876

1874

1872

1870

Sh

ut-

in P

seu

do

pre

ssu

re,

pp

ws, p

sia

20151050

dppws/dta, psi/hr

Well C-IV-11 (A-084) [Test Date: 4 May 1992]

pp,bar = 1882.8 psia

Onset of boundarydominated flow.

"Transient flow"

Sh

ut-

in p

seu

do

pre

ss

ure

, psi

a

dppws/dta, psi/hr

Example 4: Muskat Plot (single well pavg plot)

Well C-IV-11 (A-084) [Test Date: 4 May 1992]

Page 33: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

40

30

20

10

0

(p

p')

t a

e

302520151050

ta

2/tae, hrs

Well C-IV-11 (A-084) [Test Date: 4 May 1992](

pp')

ta

e, p

si

ta2/ tae

Example 4: "Well Interference" Plot (radial flow only)

Well C-IV-11 (A-084) [Test Date: 4 May 1992]

Intercept is used tocalculate permeability.

Slope is used in thepressure correction.

(pp')tae >0, no clear indication of

multiwell interference effects.

Page 34: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

16000

15000

14000

13000

12000

11000

10000

9000

8000

7000

6000

5000

4000

3000

550050004500400035003000250020001500100016000

15000

14000

13000

12000

11000

10000

9000

8000

7000

6000

5000

4000

3000

x-p

osi

tio

n (

rela

tive

dis

tan

ce)

5500500045004000350030002500200015001000

y-position (relative distance)

A-015

A-016

A-017

A-021

A-022ST2

A-024

A-025ST

A-027

A-029

A-032A-032ST

A-033

A-034

A-035

A-036

A-040

A-041

A-042

A-045

A-046

A-048

A-049

A-051

A-053

A-054

A-058

A-059

A-060

A-061

A-062

A-067

A-068

A-070

A-071

A-073

A-074

A-076

A-077

A-078

A-079ST

A-080

A-081

A-082

A-083

A-084A-085

A-088

A-089

A-091

A-092

A-093

A-095

A-096

A-097

A-098

A-099

A-100

A-101

A-102

A-103

A-104

A-105ST2

A-106

A-107

A-108

A-109

A-110ST

100000

80000 60000

50000

50000

50

00

0

40000

40000

40000

40

00

0

40000

40000

30000

30

00

0

30

00

0

30

00

0

30

00

0

30000 20

00

0

20000

20

00

0

20

00

0

20

00

0

20

00

0

20000 20

00

0

10000

10000

10

00

0

10

00

0

10

00

0

10

00

0

10

00

0

10

00

0

10000

10

00

0

Flow Capacity (kh, md-ft)from Well Test Analysis (Arun Field, Indonesia)

Legend: (Well Test Analysis)

Flow Capacity ( kh) Contour Plot(10,000 md-ft Contours)

Arun Field (Indonesia)

1x2 PerspectiveViewkh distribution ap-

pears reasonable.3 major "bubbles"

of kh noted, pro-bably erroneous.

kh shown is for the "outer" zone (when the radial compo-site model is used).

kh Map

Page 35: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

This map indicates a uniform distribution.

"high" and "low" regions appear to be focused near a single well.

Relatively small data set (30 points).

D (Non-Darcy) Map 16000

15000

14000

13000

12000

11000

10000

9000

8000

7000

6000

5000

4000

3000

550050004500400035003000250020001500100016000

15000

14000

13000

12000

11000

10000

9000

8000

7000

6000

5000

4000

3000

x-p

osi

tio

n (

rela

tive

dis

tan

ce)

5500500045004000350030002500200015001000

y-position (relative distance)

A-015

A-016

A-017

A-021

A-022ST2

A-024

A-025ST

A-027

A-029

A-032A-032ST

A-033

A-034

A-035

A-036

A-040

A-041

A-042

A-045

A-046

A-048

A-049

A-051

A-053

A-054

A-058

A-059

A-060

A-061

A-062

A-067

A-068

A-070

A-071

A-073

A-074

A-076

A-077

A-078

A-079ST

A-080

A-081

A-082

A-083

A-084A-085

A-088

A-089

A-091

A-092

A-093

A-095

A-096

A-097

A-098

A-099

A-100

A-101

A-102

A-103

A-104

A-105ST2

A-106

A-107

A-108

A-109

A-110ST

-3

.4

-3

.6

-3

.6

-3.8

-3

.8

-3.8

-3

.8

-3

.8

-4

-4

-

4

-4

-4

-4

.2

-4.2

-4.2

-4

.2

-4

.2

-4

.4

-4

.4

-4

.4

-4.6

-4

.6

-4.6

-4.6

-4.6

-4.8

-4.8

-4.8

-5

-5

Logarithm of the Non-Darcy Flow Coefficient (D, 1/MSCFD)from Well Test Analysis (Arun Field, Indonesia)

Legend: (Well Test Analysis)

Logarithm of the Non-DarcyFlow Coefficient

(log(10) Contours)

Arun Field (Indonesia)

No Data

1x2 PerspectiveView

Page 36: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Good distribution of values—"high" spots probably indicate need for individual well stimulations.

Relatively small data set (32 points).

Condensate Radius Map 16000

15000

14000

13000

12000

11000

10000

9000

8000

7000

6000

5000

4000

3000

550050004500400035003000250020001500100016000

15000

14000

13000

12000

11000

10000

9000

8000

7000

6000

5000

4000

3000

x-p

osi

tio

n (

rela

tive

dis

tan

ce)

5500500045004000350030002500200015001000

y-position (relative distance)

A-015

A-016

A-017

A-021

A-022ST2

A-024

A-025ST

A-027

A-029

A-032A-032ST

A-033

A-034

A-035

A-036

A-040

A-041

A-042

A-045

A-046

A-048

A-049

A-051

A-053

A-054

A-058

A-059

A-060

A-061

A-062

A-067

A-068

A-070

A-071

A-073

A-074

A-076

A-077

A-078

A-079ST

A-080

A-081

A-082

A-083

A-084A-085

A-088

A-089

A-091

A-092

A-093

A-095

A-096

A-097

A-098

A-099

A-100

A-101

A-102

A-103

A-104

A-105ST2

A-106

A-107

A-108

A-109

A-110ST

40

35

35

3

0

30

30

30

25

25

25

25

25

25

25

25

20

2

0

20

20

20

15

15

15

15

10

10

10

10

10

10

7

7

7

7

5

5

5

5

5

3 3

3

1

Condensate Bank Radius (ft) from Well Test Analysis(Arun Field, Indonesia)

Legend: (Well Test Analysis)

Condensate Bank Contour Plot(Various Contours)

Arun Field (Indonesia)

No Data

1x2 PerspectiveView

Page 37: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

10-6

10-5

10-4

10-3

103

104

105

106

103

104

105

106

103

104

105

106

Comparison of Non-Darcy Flow Coefficient (D) from Well TestAnalysis versus Flow Capacity (kh) from Well Test Analysis

(Arun Field -- Indonesia)

Legend: DWT vs. khWT

Comparison of D from Well Test Analysis versus kh from Well Test Analysis

(Arun Field -- Indonesia)

No

n-D

arc

y F

low

Co

eff

icie

nt

(D,

1/M

SC

FD

)fr

om

We

ll T

es

t A

na

lys

is (D

at

Tim

e o

f W

ell

Te

st)

Flow Capacity (kh, md-ft)from Well Test Analysis (kh at Time of Well Test)

D-kh crossplot indi-cates an "order of magnitude" correla-tion.

Verifies that non-Darcy flow effects are systematic.

D (Non-Darcy)—kh Crossplot

Slope = 2

Page 38: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Conclusions

The new "multiwell" solution has been successfully derived and applied for the analysis of well test data taken from a multiwell reservoir system.

The appearance of "boundary" effects in pressure buildup test data taken in multiwell reservoirs can be corrected using our new approach. Care must be taken so as not to correct a true "closed boundary" effect.

Page 39: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Conclusions

The 2-zone radial composite reservoir model has been shown to be representative for the analysis and interpretation of well test data from Arun Field (most of the wells exhibit radial composite reservoir behavior).

Page 40: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

Conclusions

The effect of non-Darcy flow on pressure buildup test analysis seems to be minor for the wells in Arun Field. Although not a focus of the present study, our analysis of the pressure drawdown (flow test) data appear to be much more affected by non-Darcy flow effects.

Page 41: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

SPE 56487

Analysis and Interpretation ofWell Test Performance at Arun Field, Indonesia

Authors:T. Marhaendrajana, Texas A&M U.

N.J. Kaczorowski, ExxonMobil (Indonesia)T.A. Blasingame, Texas A&M U.

Page 42: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

10-2

10-1

100

psD

' or

psD

e' o

r p

sDc' ,

[p

ws-p

wf(t=

0)]

fo

rma

t

10-6

10-5

10-4

10-3

10-2

tDA or tDAeDim

. Pre

ssur

e D

eriv

ativ

e F

unc

tion

s

tDA or tDAe

tpDA=10-5

tpDA=10-4tpDA=10-3

tpDA=10-2

Agarwal eff.shut-in time

Shut-in time

The "Regional Pressure Decline" Improves The Derivative

Page 43: SPE 56487 Analysis and Interpretation of Well Test Performance at Arun Field, Indonesia Authors: T. Marhaendrajana, Texas A&M U. N.J. Kaczorowski, ExxonMobil

9

8

7

6

5

4

3

ps

D o

r p

sD

c, [

pw

s-p

wf(t=

0)]

form

at

10-6

10-5

10-4

10-3

10-2

tDA or tDAe tDA

or tDAe

psD

or

psD

c [p

ws

- p

wf(

t=0

)] fo

rma

t

Agarwal effective time

MDH

tpDA=10-5tpDA=10-4tpDA=10-3tpDA=10-2