sonet sdh quickref
TRANSCRIPT
gige Ethernet test gige Ethernet testing gige Ethernet installation gige Ethernet maintenance gige Ethernet commissioning, gige Ethernet troubleshooting,
Tren
dCom
munic
atio
ns
Gigabit Ethernet tester, Gigabit Ethernet testing, Gigabit Ethernet installation, Gigabit Ethernet maintenance, Gigabit Ethernet commissioning, Gigabit Ethernet troubleshooting, Gigabit Ethernet protocols, 1000BASE-T tester, 1000BASE-LX test, 1000BASE-SX test, 1000BASE-T testing, 1000BASE-LX testing, 1000BASE-SX testing,
Gigabit Ethernet protocols, 1000BASE-T tester, 1000BASE-LX test, 1000BASE-SX test, 1000BASE-T testing 1000BASE-LX testing 1000BASE-SX testing
STM-1
STM-64
STM-16
STM-4
STM-256OC-768
OC-192
OC-48
OC-12
OC-3/STS-3
STM-0OC-1/STS-1
TUG-3
DS1
E1
DS2
DS3 E3
E4
x3
x4
x7
x7
TUG-2
x3
x3
MappingMultiplexingAligning Pointer processing
SDH Container
Group
VC-4
VC-3
VC4-4c
VC4-16c
AU-4
AU4-4c
AU4-16c
STS-3c SPE
STS-1 SPE
VT-Group
VC4-64c
VC4-256c
AU4-64c
AU4-256c
ATM
ATM
ATM
ATM
ATM
ATM
AU-3
10GbE
AUG-256
STS-12c SPE
STS-48c SPE
STS-192c SPE
STS-768c SPE
STS-3c
STS-1
STS-12c
STS-48c
STS-192c
STS-768c STS-768
AUG-64STS-192
AUG-16STS-48
AUG-4STS-12
AUG-1STS-3
x4
x4
x4
x4
40 Gbps
10 Gbps
2.5 Gbps
622 Mbps
155 Mbps
52 Mbps
Frame transmission
Figure 1 SDH and SONET multiplexing map
VC-3
VC-2
VC-12
VC-11
VT-6 SPE
VT-2 SPE
VT-1.5 SPE
POH addition
x1
x1
x1
x1
x1
x1
x1
x1
x1
x1
x1
x1
C-3
C-2
C-12
C-11
C-4-256c
C-4-64c
C-4-16c
C-4-4c
C-4
TU-3
TU-2
TU-12
TU-11
VT-6
VT-2
VT-1.5
x1
STS-1 SPE
904
SOH
LOH
SPE ptr
1 3STS-1
STS POH
90B1 E1
*A1 *A2 *
F1
D1 D2 D3
B2 K1 K2
D4 D5 D6
D7 D8 D9
S1 E2
D10 D11 D12
J0
M19
1
Section Overhead)
Line Overhead
9
1
H1 H2 H3 pointer
Tra
nspo
rt O
verh
ead
VT POHVirtual Tributary Path Overhead
RSOH
MSOH
AU4 ptr
1
VC4
27010
STM-1
HP POH
TU pointers
VT pointers
VT SPE VT SPE
VCn VCn
LP POHLower Order Path Overhead
500 ←s375 ←s
250 ←s
125 ←s
500 ←s375 ←s
250 ←s
125 ←s
x3
MUX
STM-1
3:1
STS-1
STS-1
STS-1
Figure 2 STS-1 and STM-1 frames
4
G1
F2
H4
J1
B3
C2
Z3Z4
N1
G1
F2
H4
J1
B3
C2
F3K3
N1
ptr
V5
V5
ptr
ptr
V5
V5
ptr
K4N2
J2V5
Z7Z6
J2V5
9
1
(payload)
270101 9
Trend’s SDH/SONETPocket Guide
Vic
tori
aCo
mb
o
Gigabit Ethernet test, Gigabit Ethernet testing, Gigabit Ethernet installation, Gigabit Ethernet maintenance, Gigabit Ethernet commissioning, Gigabit Ethernet troubleshooting, Gigabit Ethernet protocols, Gigabit Ethernet Alarms, Gigabit Ethernet test, Gigabit Ethernet test, Gigabit Ethernet test, Gigabit Ethernet tester
Tren
dCom
munic
atio
ns
Section
VC-4 (VC-3)
MSOH MSOH
RSOH
VC-11, VC-12, VC-2, VC-3
RSOH RSOH
Pat
hs
Se
cti
on
sLay
ers
RSOH
Section
Line
STS Path
Section
Line/Mux
STS SPE
LOH LOH
SOH
VT Path
Section
Line
STS Path
VT PathVTn SPE
SOH SOH
Pa
ths
Se
cti
on
s
La
yers
SOH Section
SDH
SONET
Terminal multiplexer Multiplexer Terminal multiplexerRegenerator Regenerator
Figure 3 SDH and SONET layered client/server model
Section
Mux
HO Path
LO Path
Section Section
Mux
HO Path
LO Path
Section
Mux
Section
NN NN S S I D I D I D I D I D
N N N N S S I D I D I D I D I D
Pointer Value
H1 or V1 H2 or V2
SS: Unspecified I: Invert if increment
Concatenation
NDF
NN NN S S I D I D I D I D I D
0 1 1 0 S S 0 1 0 1 1 0 1 1 0 1
0 1 1 0 S S 1 1 1 1 0 0 0 1 1 1
0 1 1 0 S S 0 1 0 1 1 0 1 1 1 0
0 1 1 0 S S 0 0 0 0 1 1 1 0 0 0
0 1 1 0 S S 0 1 0 1 1 0 1 1 0 0
0 1 1 0 S S 0 1 0 1 1 0 1 1 0 1
0 1 1 0 S S 0 1 0 1 1 0 1 1 0 1
i
i+1
i+2
j
j+1
j+2
Frame
Incr
em
ent
Decr
em
ent
Pointer MovementN NN N S S I D I D I D I D I D
1 0 0 1 S S x x x x x x x x x x
New Pointer
NDF enabled: NNNN=1001
N: New Data Flag
NDF disabled: NNNN=0110
(0001, 1101, 1011, 1000 also accepted)
(1110, 1010, 0100, 0111 also accepted)
New pointer value
H3 or V3
Negativejustification
Payload
Positivejustification
D: Invert if decrement
1 0 0 1 S S 1 1 1 1 1 1 1 1 1 1
C-3
H1H2H3
AU-4 ptr / STS ptr
G1F2H4
J1B3C2
F3K3N1
YH1 Y 1H2 1 H3H3 H3
AU-4 / STS3c
TU-3
Y: 1001SS111: all 1s byte
V1
V2
V3
V4
TU-n / VT-m SPE
x00
x01
x10
x11
Payload
H1H1 H1 H2H2 H2 H3H3 H3
AU-3 / STS-1AU-3 ptr / STS ptr
C-3
H1H2H3
Payload
TU3 ptr
V1
V2
V3
TU-n ptr
VC-n
VT ptr
Payload
Figure 4 Pointer formats, codification and procedures
G1F2H4
J1B3C2
F3K3N1
G1F2H4
J1B3C2
F3K3N1
STS ptr
Gigabit Ethernet test, Gigabit Ethernet testing, Gigabit Ethernet installation, Gigabit Ethernet maintenance, Gigabit Ethernet commissioning, Gigabit Ethernet troubleshooting, Gigabit Ethernet protocols, Gigabit Ethernet Alarms, Gigabit Ethernet test, Gigabit Ethernet test, Gigabit Ethernet test, Gigabit Ethernet tester
Tren
dCom
munic
atio
ns
Figure 5 STM-N/OC-M frames
* Non-scrambled bytesX bytes reserved for national use^ Media-dependent bytes
B1 ^ ^ E1 ^
*A1 *A1 *A1 *A2 *A2 *A2 * *
F1
D1 ^ ^ D2 ^ D3
Pointer (s)
B2 B2 B2 K1 K2
D4 D5 D6
D7 D8 D9
S1 E2
D10 D11 D12
M1
STM-1/STS-3/OC-3
X
X
X
X
X
J0 *
X
B1 E1
*A1 *A2 *
F1
D1 D2 D3
B2 K1 K2
D4 D5 D6
D7 D8 D9
S1 E2
D10 D11 D12
STS-1/STM-0J0
M1
B1
*A1 *A1 *
D1
B2 B2 B2
D4
D7
S1
D10
A1 *A1
B2
^
*A1
^
B2
^
*A1
^
B2
E1
*A2
D2
K1
D5
D8
D11
*A2 *A2
M1
*A2
^
*A2
^
^
*A2
^
*A2 *A2
F1
*J0
D3
K2
D6
D9
E2
D12
X
*Z0
X
X
*Z0
X
X
*Z0
X
X
*X
X
X
*X
X
^
*A1
^
B2
^
*A2
^
*A2
X
*X
X
Pointer (s)
1 13 25 36 STM-4/OC-4
B1 +
*A1 *A1 *
+
D1 + +
B2 B2 B2
D4
D7
S1 +D10
A1
+
^
*A1
^
B2
^
*A1
^
B2
+
E1
*A2
D2
K1
D5
D8
D11
+
*A2
++
*A2
+
M1
+
*A2
+^
*A2
^
^
*A2
^
+
*A2
+
*A2
+
+
F1
*J0
D3
K2
D6
D9
E2
D12
X
*Z0
+
+++
X
+
X
*Z0
+
+++
X
+
X
*X
X
X
*X
+
+++
X
+
X
*X
+
+++
X
+
^
*A1
^
B2
+
^
*A2
^
+
+
*A2
+
+
X
*X
$
+++
X
+
Pointer (s)
1 49 97 144 STM-16/OC-48
D1-D3: 192 kbps OA&M dataD4-D12: 576 kbps OA&M dataE1, E2: 64 kbps orderwire channels
M0, M1: Re-sending of B2 errors
F1: 64 kbps user channelH1, H2, H3: pointer bytes
Z0: reserved
K1, K2: Request/answer APS channelsF1: 64 kbps user channel
A1= 11110110 Frame Alignment
B1: Section Parity Code BIP-8B2: Multiplex Parity Code BIP-n x 24
J0: Section Trace
17
^
*A1
^
B2
^
*A1
^
B2
+
^
*A1
^
B2
+
33 65 81 113
X
*X
X
129
X
*X
$
+++
X
+
B1 +
*A1 *A1 *
+
D1 + +
B2 B2 B2
D4
D7
S1 +D10
A1
+
^
*A1
^
B2
^
*A1
^
B2
+
E1
*A2
D2
K1
D5
D8
D11
+
*A2
+
M0
+
*A2
+
M1
+
*A2
+^
*A2
^
^
*A2
^
+
*A2
+
*A2
+
+
F1
*J0
D3
K2
D6
D9
E2
D12
X
*Z0
+
+++
X
+
X
*Z0
+
+++
X
+
X
*X
X
X
*X
+
+++
X
+
X
*X
+
+++
X
+
^
*A1
^
B2
+
^
*A2
^
+
+
*A2
+
+
X
*X
$
+++
X
+
Pointer (s)
1 193 385 576 STM-64/OC-192
^
*A1
^
B2
^
*A1
^
B2
+
^
*A1
^
B2
+
X
*X
X
X
*X
$
+++
X
+
+ + P1FEC sequence:
$ $ Q1 P1 P1 P1151
FEC sequence:
P1 P1 P1 P1 P1 P1P1 P1
Q1 P1 P1 P1161
P1 P1 P16320
STM-16/OC-48 STM-64/OC-192
1 9
99
11
9
1
9
1
9
1
+, $: FEC sequences
Q1, P1: Optional Forward Error Correction
H1 H2 H3
A2= 00101000: Frame Alignment
Gigabit Ethernet test, Gigabit Ethernet testing, Gigabit Ethernet installation, Gigabit Ethernet maintenance, Gigabit Ethernet commissioning, Gigabit Ethernet troubleshooting, Gigabit Ethernet protocols, Gigabit Ethernet Alarms, Gigabit Ethernet test, Gigabit Ethernet test, Gigabit Ethernet test, Gigabit Ethernet tester
Tren
dCom
munic
atio
ns
V3 V3
V5
34 bytes
J2
34 bytes
N2
34 bytes
K4
34 bytes
Data32 bytes
Figure 6 Synchronous and asynchronous transport of a 2-Mbps circuit (I)
Synchronous
125 ←s
500 ←s
R: Fixed stuff bitO: Overhead bitsCi: Justification control bitsSi: Justification
D: Data bit
STM-1 VC-4AU-4 VC-12TUG-2 TU-12AUG
+LO-POH+AU pointer +HO-POH
E2
+ Stuffing+ Justification+ Overhead
+RSOH+MSOH
x3
12346789
TUG-3
5
x7x3
S2 DDDDDDDC1C2RRRRRS1
TS0Channels1 to 15TS16
Channels16 to 30
CAS RRRRRRRR
RRRRRRRR
32 bytes
RRRRRRRR
RRRRRRRR
Data32 bytes
C1C2OOOORR
RRRRRRRR
Data32 bytes
C1C2OOOORR
RRRRRRRR
Data32 bytes
RRRRRRRR
Data31 bytes
Asynchronous
TS0
Time Slot1 to 31
CCS 1
byte 34
VC-12
22
11 C-12C-12
V1
35 bytes
V2
35 bytes
V3
35 bytes
V4
35 bytes
500 ←s
3
TU-12
H4=00
H4=01
H4=10
H4=11
V311 4
9
125 ←s
9
12
4
TUG-2
1
140
V3 V3V31
LO-POH = V5 J2 N2 K4TU-12 pointer = V1 V2 V3 V4
125 ←s
if CiCiCi=111, then Si is a justification bitif CiCiCi=000, then Si is a data bit
C-12
125 ←s
#1 #2 #3
Gigabit Ethernet test, Gigabit Ethernet testing, Gigabit Ethernet installation, Gigabit Ethernet maintenance, Gigabit Ethernet commissioning, Gigabit Ethernet troubleshooting, Gigabit Ethernet protocols, Gigabit Ethernet Alarms, Gigabit Ethernet test, Gigabit Ethernet test, Gigabit Ethernet test, Gigabit Ethernet tester
Tren
dCom
munic
atio
ns
RSOH
MSOH
AU4 ptr
R
NPI
Figure 7 Synchronous and asynchronous transport of a 2-Mbps circuit (II)
9
1 TUG-2 12
9
86
TUG-31
9
1 TUG-2 12
9
1 TUG-2 12
#1 #2 #7
9
1 TUG-2 12
#3
R
1 2 3 4 5 6 7 1 2.......
5
TUG-3
x 7
TUG-3
R
NPI
R
10
9
11 9
VC-4270
+HO-POH10
G1
F2
H4
J1
B3
C2
F3
K3
N1
R
13
6
Byte-interleaving3 TUG-3
7
8
STM-1 9
#1 #2
11 12
R
NPI
R
#3
VC-4
H4=xx11
STM-1RSOH
MSOH
VC-4
H4=xx10
STM-1RSOH
MSOH
VC-4
H4=xx01
STM-1RSOH
MSOH
VC-4
H4=xx00
STM-1RSOH
MSOH
125 ←s
500 ←s
V1
V2
V3
V4
H4=xx00
H4=xx01
H4=xx10
H4=xx11
VC-12
125 ←s
TUG-2 TUG-2 TUG-2#1 #2 #7
500 ←s
TUG-3
#1
TUG-3
#1
TUG-3
#1
x7
x3
x3 x7 x3
Figure 8 VC-12 is a multiframe and needs four STM-1 frames (500 ←s) for full mapping.
x3 x7 x3 x3 x 7
x3
x3
Gigabit Ethernet test, Gigabit Ethernet testing, Gigabit Ethernet installation, Gigabit Ethernet maintenance, Gigabit Ethernet commissioning, Gigabit Ethernet troubleshooting, Gigabit Ethernet protocols, Gigabit Ethernet Alarms, Gigabit Ethernet test, Gigabit Ethernet test, Gigabit Ethernet test, Gigabit Ethernet tester
Tren
dCom
munic
atio
ns
REI (Remote Error Indication) BIP-8 violation count
RDIG1:
RDI (Remote Defect Indication) is sent back
00: unequipped01: reserved02: TUG03: locked TU04: E3, T3
14: DQDB15: FDDI
xx11xx00: pointer to V1xx11xx01: pointer to V2xx11xx10: pointer to V3xx11xx11: pointer to V4
Nine bytes Path Overhead (POH)
Path trace, message with CRC
BIP-8 parity control
Signal label (mapping)
Path status
Path user channel (voice or data)
Position and sequence indicator
Path user channel (voice or data)
Automatic Protection Switch
Tandem Connection Monitoring
G1
F2
H4
J1
B3
C2
F3
Z3Z4
16: HDLC/PPP
18: HDLS/LAPS1A: 10GEthernetFE: Test-Signal
SpareE-RDI
IEC Incoming Error Count, BIP-8 errors in Tandem Conn.
IEC TCN1:REI OEI
TC-API, TC-RDIODI, reserved
E-RDI (Enhanced RDI information)
TC-REI: Remote Error Indication in a TC subnetworkOEI: Outgoing Error IndicationMultiframe: TC-API (Access Point Identifier)
multiframe
17: SDL
(RDI=0) 10: Payload defect (PLM)(RDI=1) 01: Server defect (AIS, LOP), (RDI=1) 10: Connectivity defect (TIM, UNEQ)
LO Multiframe Sequence
BIP-2V5:
ESL (Extended Signal Label) 32 bits multiframe
REI RFI RDI
BIP-2 bit 1: odd bit parity of the previous VCbit 2: even bit parity
Signal Label
RDI (Remote Defect Indication)
VC signal label (mapping)000 - Unequipped001 - Reserved010 - Asynchronous floating011 - Bit synchronous 100 - Byte synchronous
Path Overhead
Reserved or TCM
APS: Automatic Protection Switching channel
Path Trace
V5
J2
N2
K4
V5
J2
N2
K4
500
←s
101 - Extended signal label110 - Test Signal O.181
Additional Path Overhead
REI (Receive Error IndicationRFI (Remote Failure Indication
bits 1-11 Multiframe Alignmentbits12-19:
0A: HDLC/PPP0B: HDLC/LAPS0C: Concatenated test signal
DL: Lower-Order Data Link
BIP-2 for Tandem Connection calculated over the VC
BIP-2 I-AISN2: OEITC-API, TC-RDIODI, reserved
TC-REI: Remote Indication Error in a TC subnetworkOEI (Outgoing Error Indication)
multiframe
1 TCREI
I-AIS: Incoming AIS
111 - VC- AIS
K4: APS DLE-RDIESL VC
Four bytes Path Overhead (POH)
bits 20-32: 0 (reserved for future)VC (Lower Order Virtual Concatenation)
ODI (Outgoing Defect Indication)
VC-3/4-Xv sequencebit 5-8: MFI1 multiframe indicator (0 to 15)frame 0 bit 1-4 MFI2 MSB Multiframe Indicator 2frame 1 bit 1-4 MFI2 LSBframe 14 bit 1-4 SQ MSB sequence indicatorframe 15 bit 1-4 SQ LSB sequence indicator
12: E413: ATM
H4:C2:
APS: Automatic Protection
K3:
HODL: Higher Order Data Link
x x 1 1
H4: Multiframe Indicator 1MFI2 (frames 0 and 1)SQ (frames 14 and 15)
09: ATM
E-RDI (Enhanced RDI information)(RDI=0) 010: Payload defect (PLM)(RDI=1) 101: Server defect (AIS, LOP), (RDI=1) 110: Connectivity defect (TIM, UNEQ)
TC-RDI (RDI in Tandem Connection)
Multiframe: TC-API (Access Point Identifier)
ODI (Outgoing Defect Indication)TC-RDI (RDI in Tandem Connection)
G1
F2
H4
J1
B3
C2
F3
K3N1
SDH SONET
V5
J2
Z6
Z7
SDH SONET
APS SpareHODL
Figure 9 Nine bytes Path Overhead is attached to VC3, VC4 and VC4-Xc. Four bytes Path Overhead is attached to VC11, VC12 and VC2.
REI
LO Seqx x
Gigabit Ethernet test, Gigabit Ethernet testing, Gigabit Ethernet installation, Gigabit Ethernet maintenance, Gigabit Ethernet commissioning, Gigabit Ethernet troubleshooting, Gigabit Ethernet protocols, Gigabit Ethernet Alarms, Gigabit Ethernet test, Gigabit Ethernet test, Gigabit Ethernet test, Gigabit Ethernet tester
Tren
dCom
munic
atio
ns
Reg. Sect. Multiplexer Section Higher Order Path Lower Order Path
LOF
LOSA1/A2
RS-TIM / TIM-SJ0
RS-BIP / CV- SB1
MS-BIP / CV- LB2
M12-8MS-REI / REI- L
MS-AIS / AIS-PK26-8
MS-REI / REI- LM1
AU-AIS / AIS- PAU ptr
MS-RDI / RDI-LK26-8
AU-LOP / LOP-PAU ptr
HP-UNEQ / UNEQ- PC2
HP-PLM / PLM-PC2
HP-BIP / CV- PB3
G11-4HP-REI / REI-P
HP-RDI / RDI-PG15-7
HP-REI / REI-PG11-4
TU-LOM / LOMH47-8
TU-AIS / AIS-VTU ptr
TU ptr TU-LOP / LOP-V
J2 LP-TIM / TIM-V
V55-7LP-PLM / PLM-V
LP-BIP/ CV-VV51-2
V53LP-REI / REI-V
LP-REI / REI-VV53
V58LP-RDI / RDI-V
Transmission Line
HP-TIM / TIM-PJ1
V55-7LP-UNEQ / UNEQ-V
Event detection
Signal flow
Error indication received
Error indication sent
Alarm indication sent
OR (logical function)
Event registration
Sonet
Section Line STS Path VT PathTransmission
AIS
AIS
AIS
AIS
AIS
AIS
Signal
LP-RFI / RFI-VV54
Figure 10 Events management. SDH in regular characters, SONET in italic.
SDH
Trend Communications Ltd.Whitebrook Park,Lower Cookham Road,Maidenhead,Berkshire, SL6 8XY, UK
TrendCommunications+44 1628 50350001628 50353101 69 35 54 70089 32 30 09 3093 300 331311 255541611 256 461 07901 877 [email protected]
International:United Kingdom:
France:Deutschland:
España:India:
Canada /Latin America:US Toll Free:
Email:Web:
More information in:
Installation and Maintenance of SDH/SONET,
2003 (c) Artech House, ISBN:1580535259 ATM, XDSL, and Synchronization Networks.
E1 test, E1 testing, E1 installation, E1 maintenance, E1 commissioning, E1 Set up, E1 tester, E1 pocket guideE1 protocols, DS0, Alarms, AIS test, BER test, CAS test, CRC test, E1 Solutions, PDH solutions, PDH pocket guide
Acronyms
AIS Alarm Indication Signal NDF New Data Flag
API Access Path Identifier OA&M Operation, Administration and Maintenance
APS Automatic Protection Switching OC-n Optical Carrier level n
ATM Asynchronous Transfer Mode ODI Outgoing Defect Indication
AU Administrative Unit OEI Outgoing Error Indication
AUG Administrative Unit Group PLM Payload Mismatch
BIP Bit-Interleaved Parity POH Path Overhead
CV Code Violation PPP Point to Point Protocol
DQDB Distributed Queue Dual Bus RDI Remote Defect Indication
ESL Extended Signal Label REI Remote Error Indication
FDDI Fibre Digital Data Interface RFI Remote Failure Indication
FEC Forward Error Correction RS Regenerator Section
HDLC High-level Data Link Control RSOH Regenerator Section Overhead
HODL Higher Order Data Link SDH Synchronous Digital Hierarchy
HP Higher Order Path SOH Section Overhead
LAPS Link Access Procedure – SDH SONET Synchronous Optical Network
LO Path Lower Order Path SPE Synchronous Payload Envelope
LOF Loss of Framing STM-n Synchronous Transport Module level n
LOH Lower Order Overhead STS-n Synchronous Transport Signal level n
LOM Loss Of Multiframing TC Tandem Connection
LOP Loss Of Pointer TIM Trace Identifier Mismatch
LOS Loss Of Signal TS Time Slot
LP Lower-Order Path TU Tributary Unit
MS Multiplexor Section TUG Tributary Unit Group
MSOH Multiplexor Section Overhead VC Virtual Container
MUX Multiplexor VT Virtual Tributary
Distributor:
Re
f: 70
070
0 0
2 05
.05