solid state relays asp - intechintech systems chennai pvt ltd s-2, guindy industrial estate chennai...
TRANSCRIPT
01
Sens
ing
Tow
er La
mps
Cabl
es &
Elec
trode
sSw
itchi
ngCo
ntro
lW
eigh
ing
Auto
mat
ion
Pow
erSu
pplie
sAc
cess
orie
sSw
itchi
ng
Solid State RelaysASP
1Ø & 3Ø Economical Compact Size Operation Indicator Zero Cross Function 1Ø- 350A; 3Ø- 3 x 120A O/p voltage 24 ~ 480 VAC
SALIENT FEATURES
www.inno.sg/asp
Model Number Legend
2 3 41
1. Series
ASP
Example:ASP-CDA-40AASP Series - Compact General Purpose SSR, 3-32 VDC Control Voltage & 40-440VAC Load voltage, 40A Load Current
NOTE: Contact us for models not shown in catalogue
General Purpose
2. Type
C : Compact, General Purpose
L : Long, General Purpose
3 : 3 Phase, General Purpose
4. Load Current
10A : 10 Ampere
16A : 16 Ampere
25A : 25 Ampere
40A : 40 Ampere
60A : 60 Ampere
80A : 80 Ampere
100A : 100 Ampere
120A : 120 Ampere
150A : 150 Ampere
200A : 200 Ampere
250A : 250 Ampere
300A : 300 Ampere
350A : 350 Ampere
3. Control/ Load Voltage
AA : 90-250 VAC/ 24- 440VAC
DA : 3-32 VDC/ 24- 440VAC
DD : 5-32 VDC/ 12-250 VDC
02
Sens
ing
Tow
er La
mps
Cabl
es &
Elec
trode
sSw
itchi
ngW
eigh
ing
Cont
rol
Pow
erSu
pplie
sAu
tom
atio
nAc
cess
orie
s
www.inno.sg/asp
Switc
hing
Ratings and Speci�cations
Heatsink Selection
ASP
Note: All parameters are measured with and ratings calculated with/ without heatsink ensuring that temperature does not exceed 40° C Suitable heatsinks are available; refer ASH catalogue (www.inno.sg/ash)
Rating 15 ~ 80 A 10 ~ 100 A 15 ~ 40 A 100 ~ 350 A 20 ~ 120 A
Models ASP-CAA - __ ASP-CDA - __ ASP-CDD - __ ASP-LDA - __ ASP-3DA - __
Type Single Phase Long Three Phase
Load Voltage 21-250 VDC 40-440 VAC 3Ø: 40-440 VAC
Load Currents(varries by model)
15A, 25A, 40A, 80A10A, 15A, 25A, 40A,
60A, 100A15A, 25A, 40A
100A, 120A, 150A, 250A, 350A
20A, 40A, 80A, 120A
Control Voltage 90-250 VAC
Control Current 5-30 mA 6-35 mA 6-25 mA 5-25 mA 5-28 mA
Turn-on/ Turn-o� Voltage 90/10 VAC 3/1 VDC 5/1 VDC
Reverse Voltage -
Transient Voltage 400 VDC 1100 VAC 1000 VAC
On-state Voltage Drop < 1.2 VDC
Switching Time max. 11 ms max. 10ms max. 5ms
Lekage Current max. 10 mA max. 5 mA
Indication
Insulation Resistance
Dielectric Strength
MTBF
Vibration Resistance
Shock Resistance
Ambient Temperature
Ambient Humidity
Weight max. 235g20, 40A: 460g; 80A: 500g; 120A: 540g
100,000 switching
500 MΩ min. at 500 VDC testing
> 2500 VAC (nom.)
10G
10 to 55 Hz, 0.75 mm (single amplitude) in X, Y, Z directions for 2 hours (destruction)
Operation: -25° ~ 70° C; Storage: -30° ~ 80° C (non-freezing; non-condensing)
Operation: 40 ~ 85% RH; Storage: 35 ~ 95% RH (non- condensing)
max. 150g
3/1 VDC
32 VDC
900 VAC
< 1.6 VAC < 1.6 VAC
max. 11 ms
max. 10 mA
RED LED
Single Phase Compact
40-440 VAC
3-32 VDC
SSR Type Load Current Heatsink Model
10A -- NA --
15A, 25A ASH-C-20
25A, 40A ASH-C-40
60A ASH-C-60
80A ASH-CL80
100A ASH-3CL-100
100A ASH-3CL-200
100A ASH-CL80
120A ASH-3CL-100
150A ASH-3CL-200
250A ASH-3CL-200
350A ASH-3CL-350
Compact
Long
SSR Type Load Current Heatsink Model
20A ASH-3-20
20A ASH-3-30
20A ASH-3L-40
40A ASH-3L-40
80A ASH-3L-80
120A ASH-3CL-200
Three Phase
Note: Heatsink selection should be in a manner that ensures that the operating temperature of the SSR does not exceed the permisible limits.
Exclusively Represented by:
© INNO, Rights ReservedIn the interest of continious product improvement
speci�cations are subject to change without notice
Intech Systems Chennai Pvt LtdS-2, Guindy Industrial Estate
Chennai - 600 032. Ph: 4353 8888Email: [email protected]
www.inno.sg
Sens
ing
Tow
er La
mps
Cabl
es &
Elec
trode
sSw
itchi
ngCo
ntro
lW
eigh
ing
Auto
mat
ion
Pow
erSu
pplie
sAc
cess
orie
s
www.inno.sg/asp
Switc
hing
All dim
ensions are in mm
03
♦ ASP-CAA- __ ♦ ASP-CDD- __♦ ASP-CDA- __
43. 5φ4 . 5 2
LED
- M5
2- M3
12. 5
57
.2 48
29
26
♦ ASP-LDA- __
94
80
42
2-φ6
13 34
43
32
6
2 - M8
LED
♦ ASP-3DA- __
10
691
2 - M3
6- M53
1.5
11 .54.8
4875
ASPDimension Drawing
Note: Connectors cable for the control input is provided along with the relay unit.
Cat.
No.
ASP
-213
LED