    SNRHA

    THE SOUTHERN NEVADA REGIONAL HOUSING AUTHORITY. 340 N. 111~STREET. LAs VEG AS, NV 89101.3611

    This Requestfor Quotenumberis Q10099 for thefollowing:

    Rehabilitationand EnergyUpgrades@4621 HutchinsonDr., Las Vegas,NV

    NeighborhoodStabilizationProgram(NSP

    QUOTE FORM

    Scope of Work4621 Hutchinson Dr., Las Vegas, NV 89147

    Work listed below shall meet the following standards:1. Home Performance Standards for Warm Climates (HPSFWC)2. Clark County Optional Specifications for Water Saving Measures, October 2009 (WSM)3. Clark County Housing Rehabilitation Specification Manual

    4. Southern Nevada Regional Housing Authority specifications

    5. Standard Materials/Appliance List included in this Work Scope6. Other requirements specifically listed in this Work Scope (incl. Installation Notes)

    7. Local building codes and amendments for new or substantially altered work

    8. Saturn Mechanical Systems Field Guide, Chapter 6 (2006)9. NSP Rental Project Standards Draft 5/25/201010. Guidelines for Complying with BPI's Technical Standards for the Air Conditioning and Heat Pump

    Professional11. When the above documents contain multiple or conflicting requirements, the most stringent shall apply

    ----------'--~--

    Repair gas leaks

    SCOPE OF WORK

    ITEM

    Health, Safety & Building Code Measures

    _._~-------------L DETAILS AMOUNT

    Correct all $measures listed onthe Building

    Inspection Report

    (attached)

    Needs to be tested, $call Southwest Gas

    iffound.

    Install self-closing hinge to door to garage

    Smoke Detectors: Replace ALL alarms and replace with hard wired smoke A 4detectors with battery backup in bedrooms and near kitchen (per code) and test pprox

    $

    $

    Install one CO Detector (not combined with smoke detector) per floor meeting

    UL-2034, per manufacturer's instructions and test

    Install matching locksets with deadbolt for all exterior doors (except glass

    sliders)

    Provide mechanical ventilation per AHSRAE 62.2.2003 based on all installed

    building shell sealing and energy efficiency measures

    ,

    (Approx 1) electricwith battery backup--- -

    (Approx 2) Entry

    and door to garage.E.g. KwiksetPolished Brass Tylo

    Entrance Knob(Combo Pack for 2doors Model #:042049948684)

    Install PanasonicWhisperGreen@

    (FV-08VKM2) 80

    CFM PremiumCeiling MountedContinuous andSpot Ventilation

    Fan withSmartAction@

    Motion Sensor, 6year warranty,Energy Star (set for

    $

    $

    s

  • 8/9/2019 SNRHA - 4621 Hutchinson Dr. 89147

    2/6

    THE SOUTHERN NEVADA REGIONAL H OU SI NG A UTHORI TY 340 N. 111 1< S T RE E T. L AS V E G AS . N V 8 91

    This Request for Quote number is Q10099 for the foll

    Rehabilitation and Energy Upgrades @4621 Hutchinson Dr" Las Veg

    Neighborhood Stabilization Program

    35 CFM

    continuous) in

    bathroom vented to

    outside uSing 5" R-

    8 reflective flex duct

    and verify exhaust

    CFM,

    Required when air I

    sealing or duct 1 1sealing,

    Combustion Appliance Zone test out and repair (to be done by contractor or

    subcontractor)

    Plumbing

    Perform Whole House Water Leak Detection Test

    Perfomn before

    making any other

    improvements,

    Results of whole

    house water leak

    test results is

    required (include

    water pressure athouse),

    $

    $

    Repair water leaks if found (inside and outside) at their source during whole

    house water leak detection test

    Water Heater

    Install 40 Gallon Direct Vent Gas Water Heater (EF ,63+ and 10+ year

    warranty) Install sediment trap on gas line, new copper water lines, cold water

    gate valve and gas flex line, Install two seismic straps, secured to studs Seal all

    penetrations, Insulate exposed hot and cold water pipes with foam pipe

    insulation (R-4 min), Use correct diameter of insulation sleeve so it fits tightly,

    RebUild water heater platform

    Modify T&P Relief line to slope a minimum of 1/4" per foot

    Replace all plastic stem or leaking angle slops with metal stem version, replace

    line to fixture,

    Laundry Room: Install Washing Machine Outlet Box and replace both angle

    stops with metal washing machine shut off valve,

    e,g, GE

    GG50T06PVJ

    Direct Vent,

    EF=0,64

    40 gal (3-4

    bedrooms) 50 gal

    (5+ bedrooms)

    Repair damaged

    drywall and air seal,

    Per code

    (Approx 8) sinks,

    toilets, etc

    e,g, Watts Water

    Technologies 2T-

    M2

    I

    I

    I

    $

    I

    I

    I

    Moisture

    Replace rain gutters and install diverter(s)

    Electrical

    Install arc fault breakers for bedrooms @ Electrical Panel

    Install approved weatherproof electrical covers for outside outlets and switches,

    Requires GFCI.

    Install GFCI receptacles per building code

    (Approx 3) e,g

    Taymac MM410W

    (2-3/4" Deep)

    (Approx 6) Garage

    and kitchen

    I

    I

    1 5$

    $

    I

    I

    Grading $

  • 8/9/2019 SNRHA - 4621 Hutchinson Dr. 89147

    3/6

    THE SOUTHERN NEVADA REGIONAL HOUSING AUTHORITY. 340 N. 11'" STREET. LAS VEGAS, NV 69101-3

    This Request for Quote number is Q10099 for the follOW

    Rehabilitation and Energy Upgrades@4621 Hutchinson Dr.. Las Vegas

    Neighborhood Stabilization Program (N

    QUOTE FORMPage 3 of 11

    Grade yard per building code

    Total Health, Safety & Building Code Measures

    Energy Efficiency Measures

    Infiltration

    Reduce air leakage of the building shell to: 750 CFM50

    Air sealing can be done with gun foam, caulk and stucco patch .

    Begin air sealing largest holes and attic by passes. e.g. gaps around supplies

    and returns to first floor .

    Seal all connections to the altic (highest) from the altic where possible. e.g

    recessed cans, supply and return boots, smoke detectors, light fixtures,

    electrical and plumbing in drywall and top plates, seams in top plates.

    Seal VOids where plumbing p'pes penetrate walls e.g. shower heads, toilets,

    under sinks, recessed clothes washer and ice box.

    Seal holes in interior finishes, around door frames, at strike plates, stairs,

    thermostat(s), medicine cabinets, etc .

    Seal sill plates and fireplace .

    Seal exterior penetrations. e.g cable wire, holes ,n stucco, around doors,

    doorbell, electrical outlets/switches, wall connections with garage, etc . Seal all outdoor light fixtures to wall. Leave boltom of f,xture unsealed .

    Weatherstrip doors.

    Doors

    Replace exterior front entry door and frame with ENERGY STAR rated

    insulated metal panel door (R-6.5 or greater) No Windows. Install sealed peep

    hole

    Weatherstrip doors

    Windows (sq ttl

    Replace windows and install Double Low-E Vinyl/Composite Windows

    (U=O.30/SHGC=O.30) or lower

    HVAC & Duct Insulation

    Replace existing rooftop HVAC system(s) and install properly sized 16+ SEER

    AC and 92+ AFUE gas furnace If feasible, install a split system in attic. Provide

    supporting Manual J, Sand D (where feasible to change) calculations based on

    all included energy effiCiency measures. Install new R-8 optimized duct design

    where feasible, minimizing duct length, located close to attic floor to be buried

    under insulation. Seal ducts to $6% (Leakage to Outside) Use OBD supply

    grills with operable curved blades. Install 7 day programmable thermostat(s)

    and program (e.g. Goodman TSTATG3273).

    Finish site grading $

    requires 6"

    clearance from

    earth to wood

    items; 2" clearancefrom concrete

    Smooth ground

    eliminating all

    holes

    $

    $

    $

    $

    Seal soffiVbypass

    above front

    windows .

    $

    e.g. Benchmark by $

    Therma-Tru 36"W

    6.Panel Smooth

    Fiberglass Door (R-

    8)

    Garage $

    $

    ALL windows and $

    slider ( approx.175

    sq ft.)

    Manual J, Sand D

    must be performed

    by a registered

    professional

    mechanical

    engineer.

  • 8/9/2019 SNRHA - 4621 Hutchinson Dr. 89147

    4/6

    Approx 1

    THE SOUTHERN NEVADA REGIONAL HOUSING AUTHORITY. 340 N. 11T~ STREET. lAS VEGAS, NV 8910

    This Request for Quote number is Q1 0099 for the follo

    Rehabilitation and Energy Upgrades @ 4621 Hutchinson Dr., Las Veg

    Neighborhood Stabilization Program

    Install new electrical conduit Insulate

    SNRllA

    Pour new concrete pad for compressor

    exposed refrigerant Iineset to min of R-4 .

    Perform comprehensive AC installation and commissioning per Chapter 6 of

    the Saturn Mechanical Systems Field Guide-2006, Energy Star Checklist of

    each system

    Replace exhaust fans (except those designated for continuous ventilation) with

    Hunter 82029 Energy Star Ultra Quiet High Efficiency Bath Fan, 70 CFM, 2

    sones, 5 yr warranty, exterior ducted fan with damper and separate switch or

    humidistat and verify exhaust.

    Allie Insulation

    Increase ceiling insulation to R-49 with blown cellulose (Grade 1)

    Remove existing fiberglass batt insulation and air seal exposed penetrations.

    (See Infiltration)

    Move blown cellulose to exposed top plates and air seal exposed penetrations

    and seams. (See Infiltration)

    Eave Vent Baffles (if applicable): Remove all feasible eave vent obstructions.

    Install and seal baffles to framing with gun foam.

    After ducts have been lowered to attic floor, bury ducts in up to 8" of blown

    cellulose.

    Allic Access

    Build a 14" Insulation dam around attic access to ensure full depth of

    insulation.

    Dam can be made of wood, batt, etc. Apply foam weatherstrip around

    molding.

    Insulate Access Panel to R-30 (see detail to right)

    After

    installationlservice

    of HVAC system

    including ducts

    After air sealing

    measures taken

    with recessed lights

    After installation of

    mechanicalventilation

    After air sealing

    ceiling and framing

    penetrations

    After correctly

    installing knee wall

    insulation and air

    barrier

    $

    Insulating Allie

    Access

    Ensure accessframe will support

    the following .

    Glue y ," plywoodto drywall

    Glue and screw 3-

    4" extruded

    polystyrene (R-5/in)

    to plywood

    Glue another 3-4"

    extruded

    polystyrene (R-5/in)

    on top

    Glue and screw

    518" Type-X drywall

    to extruded

    polystyrene

    Extruded

    Polystyrene (EPS)

    - The two most

    common brands of

    XPS are Dow

    Styrofoam, which is

    blue, and Owens

    Corning Foamular,

    which is pink.

  • 8/9/2019 SNRHA - 4621 Hutchinson Dr. 89147

    5/6

    THE SOUTHERN NEVADA. REGIONAL HOUSING AUTHORITY 340 N. 11'" STREET. LAS VEGAS, NV 89101

    This Request for Quote number is 010099 for the follow

    Rehabilitation and Energy Upgrades @ 4621 Hutchinson Dr., Las Vega

    Neighborhood Stabilization Program

    Q U OT E F O RMPage g of 11

    Garage

    Repair garage door

    Insulate garage door (R-4 min)

    Repair garage door opener for proper operation

    Clean garage floor and driveway

    Attic

    Remove antennae

    Exterior

    Repair hose bib (front)

    Remove satellite dish(es), associated wiring and patch

    '(

    ~E-~;~' \J-'\ WV-/

    Remove and replace eXisting asphalt singles on roof.

    Side gate(s): Remove rust and paint

    Paint all exterior building surfaces

    $

    $

    With radiant barrier $

    $

    $

    $

    $

    $

    $

    $

    (Approx1 ,850 sq tt) $

    Use Owens

    Corning Duration

    ~re shingles.

    Include cost to

    replace ten 4x8

    sheets of damaged

    sheathing with LP's

    Tech Shield or

    equivalent.

    Repair block wall, $

    remove mesh on

    gate and properlysecure to block

    wall.

    Complete air $

    sealing/patching of

    exterior

    penetrations before

    painting (see

    infiltration)

    Site / Landscaping

    Treat home for pests/bugs

    Test all spnnkler valves and heads and emitters. Repair as needed.

    Use

    environmentally

    and pet safeproducts

    $

    $

    $

    Paving

    Fences/walls

    Remove red pavers $

    in entry and fill with

    cement. (approx

    100 sq tt)

    Remove wood on $

    entry fence. Repair

    any damage to

    block wall.

  • 8/9/2019 SNRHA - 4621 Hutchinson Dr. 89147

    6/6

    THE SOUTHERN NEVADA REGIONAL HOUSING AUTHORITY 340 N 11'HSTREET. LAS VEGAS, NV 89101-36

    This Request for Quote number is Q10099 for the followin

    Rehabilitation and Energy Upgrades@ 4621 Hutchinson Dr., Las Vegas,

    Neighborhood Stabilization Program (NS

    QUOTE FORMPage 10 of 11

    Clean up and trim all landscaping. Remove dead plants in complete yardReplace dead plants In front Spray for weeds.

    Fill in missing/thin rock to match in front

    Install fines on side and backyard

    Tolal Non-Energy Efficiency Measures

    SNRHA Typical Work Items for NSP Properties (any items not included above)

    i Testing/Misc.

    Perform blower door test per attached Testing Schedule and provide written report

    Perform duct leakage for all HVAC systems test after work is completed and duct

    sealing speCIfications have been met and provide written report

    Test and calibrate all systems for proper operation per codes, manufacturer's

    specifications and HPSWFC Ch. 5, provide written report of items tested and results.

    Adjust equipment to comply with operational standards.

    Test combustion equipment and adjusUrepair as needed (per BPI PerformanceSpecifications and HPSFWC Ch. 6), provide written report of items tested and results

    Subcontracted Professionals:

    Structural Engineer (as apphcablelif not included in above work)

    Mechanical Engineer (as applicablefif not included in above work)

    Certified Energy Consultant (as applicable/if not included in above work)--- -

    . Total TestinglSubcontracted Professional

    Other Cosls

    Permit

    Dumpster/Recycling

    Remove Cyprus $

    like bush in front

    and stump.

    Remove all debns

    including bar byentry and backyard

    Tnm all vegetation

    from touching

    house walls and

    roof.

    $

    $

    $

    $

    $

    $

    $ t600

    ~ . s A 1>ov'

    _ = t-_TOTAL CONTRACTOR COSTS of ALL MEASURES

    Contractor Profit I Overhead I Other---------------------~

    Add Total CONTRACTOR COSTS of All Measures Total $

    Contract Bid

    Amount -' 11'/

    \ 1 1 ( \ l \ O JWritten amount

    Signature Printed Name Date