This Requestfor Quotenumberis Q10099 for thefollowing:
Rehabilitationand EnergyUpgrades@4621 HutchinsonDr., Las Vegas,NV
NeighborhoodStabilizationProgram(NSP
QUOTE FORM
Scope of Work4621 Hutchinson Dr., Las Vegas, NV 89147
Work listed below shall meet the following standards:1. Home Performance Standards for Warm Climates (HPSFWC)2. Clark County Optional Specifications for Water Saving Measures, October 2009 (WSM)3. Clark County Housing Rehabilitation Specification Manual
4. Southern Nevada Regional Housing Authority specifications
5. Standard Materials/Appliance List included in this Work Scope6. Other requirements specifically listed in this Work Scope (incl. Installation Notes)
7. Local building codes and amendments for new or substantially altered work
8. Saturn Mechanical Systems Field Guide, Chapter 6 (2006)9. NSP Rental Project Standards Draft 5/25/201010. Guidelines for Complying with BPI's Technical Standards for the Air Conditioning and Heat Pump
Professional11. When the above documents contain multiple or conflicting requirements, the most stringent shall apply
----------'--~--
Repair gas leaks
SCOPE OF WORK
ITEM
Health, Safety & Building Code Measures
_._~-------------L DETAILS AMOUNT
Correct all $measures listed onthe Building
Inspection Report
(attached)
Needs to be tested, $call Southwest Gas
iffound.
Install self-closing hinge to door to garage
Smoke Detectors: Replace ALL alarms and replace with hard wired smoke A 4detectors with battery backup in bedrooms and near kitchen (per code) and test pprox
$
$
Install one CO Detector (not combined with smoke detector) per floor meeting
UL-2034, per manufacturer's instructions and test
Install matching locksets with deadbolt for all exterior doors (except glass
sliders)
Provide mechanical ventilation per AHSRAE 62.2.2003 based on all installed
building shell sealing and energy efficiency measures
,
(Approx 1) electricwith battery backup--- -
(Approx 2) Entry
and door to garage.E.g. KwiksetPolished Brass Tylo
Entrance Knob(Combo Pack for 2doors Model #:042049948684)
Install PanasonicWhisperGreen@
(FV-08VKM2) 80
CFM PremiumCeiling MountedContinuous andSpot Ventilation
Fan withSmartAction@
Motion Sensor, 6year warranty,Energy Star (set for
$
$
s
-
8/9/2019 SNRHA - 4621 Hutchinson Dr. 89147
2/6
THE SOUTHERN NEVADA REGIONAL H OU SI NG A UTHORI TY 340 N. 111 1< S T RE E T. L AS V E G AS . N V 8 91
This Request for Quote number is Q10099 for the foll
Rehabilitation and Energy Upgrades @4621 Hutchinson Dr" Las Veg
Neighborhood Stabilization Program
35 CFM
continuous) in
bathroom vented to
outside uSing 5" R-
8 reflective flex duct
and verify exhaust
CFM,
Required when air I
sealing or duct 1 1sealing,
Combustion Appliance Zone test out and repair (to be done by contractor or
subcontractor)
Plumbing
Perform Whole House Water Leak Detection Test
Perfomn before
making any other
improvements,
Results of whole
house water leak
test results is
required (include
water pressure athouse),
$
$
Repair water leaks if found (inside and outside) at their source during whole
house water leak detection test
Water Heater
Install 40 Gallon Direct Vent Gas Water Heater (EF ,63+ and 10+ year
warranty) Install sediment trap on gas line, new copper water lines, cold water
gate valve and gas flex line, Install two seismic straps, secured to studs Seal all
penetrations, Insulate exposed hot and cold water pipes with foam pipe
insulation (R-4 min), Use correct diameter of insulation sleeve so it fits tightly,
RebUild water heater platform
Modify T&P Relief line to slope a minimum of 1/4" per foot
Replace all plastic stem or leaking angle slops with metal stem version, replace
line to fixture,
Laundry Room: Install Washing Machine Outlet Box and replace both angle
stops with metal washing machine shut off valve,
e,g, GE
GG50T06PVJ
Direct Vent,
EF=0,64
40 gal (3-4
bedrooms) 50 gal
(5+ bedrooms)
Repair damaged
drywall and air seal,
Per code
(Approx 8) sinks,
toilets, etc
e,g, Watts Water
Technologies 2T-
M2
I
I
I
$
I
I
I
Moisture
Replace rain gutters and install diverter(s)
Electrical
Install arc fault breakers for bedrooms @ Electrical Panel
Install approved weatherproof electrical covers for outside outlets and switches,
Requires GFCI.
Install GFCI receptacles per building code
(Approx 3) e,g
Taymac MM410W
(2-3/4" Deep)
(Approx 6) Garage
and kitchen
I
I
1 5$
$
I
I
Grading $
-
8/9/2019 SNRHA - 4621 Hutchinson Dr. 89147
3/6
THE SOUTHERN NEVADA REGIONAL HOUSING AUTHORITY. 340 N. 11'" STREET. LAS VEGAS, NV 69101-3
This Request for Quote number is Q10099 for the follOW
Rehabilitation and Energy Upgrades@4621 Hutchinson Dr.. Las Vegas
Neighborhood Stabilization Program (N
QUOTE FORMPage 3 of 11
Grade yard per building code
Total Health, Safety & Building Code Measures
Energy Efficiency Measures
Infiltration
Reduce air leakage of the building shell to: 750 CFM50
Air sealing can be done with gun foam, caulk and stucco patch .
Begin air sealing largest holes and attic by passes. e.g. gaps around supplies
and returns to first floor .
Seal all connections to the altic (highest) from the altic where possible. e.g
recessed cans, supply and return boots, smoke detectors, light fixtures,
electrical and plumbing in drywall and top plates, seams in top plates.
Seal VOids where plumbing p'pes penetrate walls e.g. shower heads, toilets,
under sinks, recessed clothes washer and ice box.
Seal holes in interior finishes, around door frames, at strike plates, stairs,
thermostat(s), medicine cabinets, etc .
Seal sill plates and fireplace .
Seal exterior penetrations. e.g cable wire, holes ,n stucco, around doors,
doorbell, electrical outlets/switches, wall connections with garage, etc . Seal all outdoor light fixtures to wall. Leave boltom of f,xture unsealed .
Weatherstrip doors.
Doors
Replace exterior front entry door and frame with ENERGY STAR rated
insulated metal panel door (R-6.5 or greater) No Windows. Install sealed peep
hole
Weatherstrip doors
Windows (sq ttl
Replace windows and install Double Low-E Vinyl/Composite Windows
(U=O.30/SHGC=O.30) or lower
HVAC & Duct Insulation
Replace existing rooftop HVAC system(s) and install properly sized 16+ SEER
AC and 92+ AFUE gas furnace If feasible, install a split system in attic. Provide
supporting Manual J, Sand D (where feasible to change) calculations based on
all included energy effiCiency measures. Install new R-8 optimized duct design
where feasible, minimizing duct length, located close to attic floor to be buried
under insulation. Seal ducts to $6% (Leakage to Outside) Use OBD supply
grills with operable curved blades. Install 7 day programmable thermostat(s)
and program (e.g. Goodman TSTATG3273).
Finish site grading $
requires 6"
clearance from
earth to wood
items; 2" clearancefrom concrete
Smooth ground
eliminating all
holes
$
$
$
$
Seal soffiVbypass
above front
windows .
$
e.g. Benchmark by $
Therma-Tru 36"W
6.Panel Smooth
Fiberglass Door (R-
8)
Garage $
$
ALL windows and $
slider ( approx.175
sq ft.)
Manual J, Sand D
must be performed
by a registered
professional
mechanical
engineer.
-
8/9/2019 SNRHA - 4621 Hutchinson Dr. 89147
4/6
Approx 1
THE SOUTHERN NEVADA REGIONAL HOUSING AUTHORITY. 340 N. 11T~ STREET. lAS VEGAS, NV 8910
This Request for Quote number is Q1 0099 for the follo
Rehabilitation and Energy Upgrades @ 4621 Hutchinson Dr., Las Veg
Neighborhood Stabilization Program
Install new electrical conduit Insulate
SNRllA
Pour new concrete pad for compressor
exposed refrigerant Iineset to min of R-4 .
Perform comprehensive AC installation and commissioning per Chapter 6 of
the Saturn Mechanical Systems Field Guide-2006, Energy Star Checklist of
each system
Replace exhaust fans (except those designated for continuous ventilation) with
Hunter 82029 Energy Star Ultra Quiet High Efficiency Bath Fan, 70 CFM, 2
sones, 5 yr warranty, exterior ducted fan with damper and separate switch or
humidistat and verify exhaust.
Allie Insulation
Increase ceiling insulation to R-49 with blown cellulose (Grade 1)
Remove existing fiberglass batt insulation and air seal exposed penetrations.
(See Infiltration)
Move blown cellulose to exposed top plates and air seal exposed penetrations
and seams. (See Infiltration)
Eave Vent Baffles (if applicable): Remove all feasible eave vent obstructions.
Install and seal baffles to framing with gun foam.
After ducts have been lowered to attic floor, bury ducts in up to 8" of blown
cellulose.
Allic Access
Build a 14" Insulation dam around attic access to ensure full depth of
insulation.
Dam can be made of wood, batt, etc. Apply foam weatherstrip around
molding.
Insulate Access Panel to R-30 (see detail to right)
After
installationlservice
of HVAC system
including ducts
After air sealing
measures taken
with recessed lights
After installation of
mechanicalventilation
After air sealing
ceiling and framing
penetrations
After correctly
installing knee wall
insulation and air
barrier
$
Insulating Allie
Access
Ensure accessframe will support
the following .
Glue y ," plywoodto drywall
Glue and screw 3-
4" extruded
polystyrene (R-5/in)
to plywood
Glue another 3-4"
extruded
polystyrene (R-5/in)
on top
Glue and screw
518" Type-X drywall
to extruded
polystyrene
Extruded
Polystyrene (EPS)
- The two most
common brands of
XPS are Dow
Styrofoam, which is
blue, and Owens
Corning Foamular,
which is pink.
-
8/9/2019 SNRHA - 4621 Hutchinson Dr. 89147
5/6
THE SOUTHERN NEVADA. REGIONAL HOUSING AUTHORITY 340 N. 11'" STREET. LAS VEGAS, NV 89101
This Request for Quote number is 010099 for the follow
Rehabilitation and Energy Upgrades @ 4621 Hutchinson Dr., Las Vega
Neighborhood Stabilization Program
Q U OT E F O RMPage g of 11
Garage
Repair garage door
Insulate garage door (R-4 min)
Repair garage door opener for proper operation
Clean garage floor and driveway
Attic
Remove antennae
Exterior
Repair hose bib (front)
Remove satellite dish(es), associated wiring and patch
'(
~E-~;~' \J-'\ WV-/
Remove and replace eXisting asphalt singles on roof.
Side gate(s): Remove rust and paint
Paint all exterior building surfaces
$
$
With radiant barrier $
$
$
$
$
$
$
$
(Approx1 ,850 sq tt) $
Use Owens
Corning Duration
~re shingles.
Include cost to
replace ten 4x8
sheets of damaged
sheathing with LP's
Tech Shield or
equivalent.
Repair block wall, $
remove mesh on
gate and properlysecure to block
wall.
Complete air $
sealing/patching of
exterior
penetrations before
painting (see
infiltration)
Site / Landscaping
Treat home for pests/bugs
Test all spnnkler valves and heads and emitters. Repair as needed.
Use
environmentally
and pet safeproducts
$
$
$
Paving
Fences/walls
Remove red pavers $
in entry and fill with
cement. (approx
100 sq tt)
Remove wood on $
entry fence. Repair
any damage to
block wall.
-
8/9/2019 SNRHA - 4621 Hutchinson Dr. 89147
6/6
THE SOUTHERN NEVADA REGIONAL HOUSING AUTHORITY 340 N 11'HSTREET. LAS VEGAS, NV 89101-36
This Request for Quote number is Q10099 for the followin
Rehabilitation and Energy Upgrades@ 4621 Hutchinson Dr., Las Vegas,
Neighborhood Stabilization Program (NS
QUOTE FORMPage 10 of 11
Clean up and trim all landscaping. Remove dead plants in complete yardReplace dead plants In front Spray for weeds.
Fill in missing/thin rock to match in front
Install fines on side and backyard
Tolal Non-Energy Efficiency Measures
SNRHA Typical Work Items for NSP Properties (any items not included above)
i Testing/Misc.
Perform blower door test per attached Testing Schedule and provide written report
Perform duct leakage for all HVAC systems test after work is completed and duct
sealing speCIfications have been met and provide written report
Test and calibrate all systems for proper operation per codes, manufacturer's
specifications and HPSWFC Ch. 5, provide written report of items tested and results.
Adjust equipment to comply with operational standards.
Test combustion equipment and adjusUrepair as needed (per BPI PerformanceSpecifications and HPSFWC Ch. 6), provide written report of items tested and results
Subcontracted Professionals:
Structural Engineer (as apphcablelif not included in above work)
Mechanical Engineer (as applicablefif not included in above work)
Certified Energy Consultant (as applicable/if not included in above work)--- -
. Total TestinglSubcontracted Professional
Other Cosls
Permit
Dumpster/Recycling
Remove Cyprus $
like bush in front
and stump.
Remove all debns
including bar byentry and backyard
Tnm all vegetation
from touching
house walls and
roof.
$
$
$
$
$
$
$ t600
~ . s A 1>ov'
_ = t-_TOTAL CONTRACTOR COSTS of ALL MEASURES
Contractor Profit I Overhead I Other---------------------~
Add Total CONTRACTOR COSTS of All Measures Total $
Contract Bid
Amount -' 11'/
\ 1 1 ( \ l \ O JWritten amount
Signature Printed Name Date