smart components for miniature modular sample systems a connectivity and communication solution...

21
Smart Components for Smart Components for Miniature Modular Sample Miniature Modular Sample Systems Systems A Connectivity and Communication A Connectivity and Communication Solution Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok Company, Solon, Ohio IFPAC San Diego, CA 1/23/2002

Post on 19-Dec-2015

217 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok

Smart Components for Miniature Smart Components for Miniature Modular Sample SystemsModular Sample Systems

A Connectivity and Communication SolutionA Connectivity and Communication Solution

Smart Components for Miniature Smart Components for Miniature Modular Sample SystemsModular Sample Systems

A Connectivity and Communication SolutionA Connectivity and Communication Solution

Richard A. Ales

David M. Simko

John J. Wawrowski

Swagelok Company, Solon, Ohio

IFPAC San Diego, CA

1/23/2002

Page 2: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok

BackgroundBackgroundBackgroundBackground

• Swagelok committed to analytical instrumentation for over 50 years

• Our response to NeSSi and subsequent work have helped define 1st generation miniature modular sample systems

• We are continually developing “fit-for-purpose” 1st generation components

• We are ready to move on to defining and developing 2nd generation components

Page 3: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok

Evolution of Modular Sample SystemsEvolution of Modular Sample SystemsEvolution of Modular Sample SystemsEvolution of Modular Sample Systems

• 1st Generation NeSSi – miniature modular achieved– ISA SP76 interface standard – Commercially available control solutions– Functional downmount components – Systems successfully installed – Benefits are being realized

• 2nd Generation NeSSi – Smart is next– Plug-n-play devices, integrated with S.A.M.– Multi-drop sensor bus communications– Self-diagnosing sample systems– Configurable device personalities– Multi-variable transducers

Page 4: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok
Page 5: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok

Smart Device ExampleSmart Device ExampleSmart Device ExampleSmart Device Example

• Switching Valve

• Hot-swap plug-n-play

• Electric Actuator

Page 6: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok

Acetylene + Hydrogen Ignition Curve

Page 7: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok
Page 8: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok

SMART Valve ExampleSMART Valve ExampleSMART Valve ExampleSMART Valve Example

Page 9: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok

Attribute Type Semantics

Command Automation Output Valve Position Indicator

Status Automation Input Valve Position Command

Device ID Smart Identity Device Description Array

Cycle Counter,Extended Status CodeForced Command

Smart Diagnostic Monitor Valve Health,Local Control

Bad Status Alarm Smart Status Fault Indicator Flag

Cycle Limit Register,Fault Action,Idle Action,Connection Format

Smart Configuration Set the valve personality

Smart Valve FeaturesSmart Valve FeaturesSmart Valve FeaturesSmart Valve Features

Page 10: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok

Automated vs. SmartAutomated vs. SmartAutomated vs. SmartAutomated vs. Smart

Feature Automated Smart

Architecture I/O Based Networked

Communications One-way, Point-to-Point Two-way, Multi-Drop

Configuration Off-line On-line Download

Asset Management Proxy On-line Upload

Diagnostics Proxy Monitored in Real-time

Process Variables Single Multiple

Control Functions DCS or PLC Local Device

Component Cost $ $$$

Total Cost of Ownership $$$ $

Page 11: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok

Feature Partition ModelFeature Partition ModelFeature Partition ModelFeature Partition Model

Page 12: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok

Hybrid OHybrid O22 Sample System Sample SystemHybrid OHybrid O22 Sample System Sample System

Page 13: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok

Hybrid OHybrid O22 Sample System Realization Sample System RealizationHybrid OHybrid O22 Sample System Realization Sample System Realization

Page 14: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok

First, Drag and Drop Device from pick list

Then, set the network address and parameters

Page 15: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok
Page 16: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok
Page 17: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok

 

Page 18: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok

 

Add Devices to create a connection.

Page 19: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok
Page 20: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok
Page 21: Smart Components for Miniature Modular Sample Systems A Connectivity and Communication Solution Richard A. Ales David M. Simko John J. Wawrowski Swagelok

Some Final ThoughtsSome Final ThoughtsSome Final ThoughtsSome Final Thoughts