smart components for miniature modular sample systems a connectivity and communication solution...
Post on 19-Dec-2015
217 views
TRANSCRIPT
Smart Components for Miniature Smart Components for Miniature Modular Sample SystemsModular Sample Systems
A Connectivity and Communication SolutionA Connectivity and Communication Solution
Smart Components for Miniature Smart Components for Miniature Modular Sample SystemsModular Sample Systems
A Connectivity and Communication SolutionA Connectivity and Communication Solution
Richard A. Ales
David M. Simko
John J. Wawrowski
Swagelok Company, Solon, Ohio
IFPAC San Diego, CA
1/23/2002
BackgroundBackgroundBackgroundBackground
• Swagelok committed to analytical instrumentation for over 50 years
• Our response to NeSSi and subsequent work have helped define 1st generation miniature modular sample systems
• We are continually developing “fit-for-purpose” 1st generation components
• We are ready to move on to defining and developing 2nd generation components
Evolution of Modular Sample SystemsEvolution of Modular Sample SystemsEvolution of Modular Sample SystemsEvolution of Modular Sample Systems
• 1st Generation NeSSi – miniature modular achieved– ISA SP76 interface standard – Commercially available control solutions– Functional downmount components – Systems successfully installed – Benefits are being realized
• 2nd Generation NeSSi – Smart is next– Plug-n-play devices, integrated with S.A.M.– Multi-drop sensor bus communications– Self-diagnosing sample systems– Configurable device personalities– Multi-variable transducers
Smart Device ExampleSmart Device ExampleSmart Device ExampleSmart Device Example
• Switching Valve
• Hot-swap plug-n-play
• Electric Actuator
Acetylene + Hydrogen Ignition Curve
SMART Valve ExampleSMART Valve ExampleSMART Valve ExampleSMART Valve Example
Attribute Type Semantics
Command Automation Output Valve Position Indicator
Status Automation Input Valve Position Command
Device ID Smart Identity Device Description Array
Cycle Counter,Extended Status CodeForced Command
Smart Diagnostic Monitor Valve Health,Local Control
Bad Status Alarm Smart Status Fault Indicator Flag
Cycle Limit Register,Fault Action,Idle Action,Connection Format
Smart Configuration Set the valve personality
Smart Valve FeaturesSmart Valve FeaturesSmart Valve FeaturesSmart Valve Features
Automated vs. SmartAutomated vs. SmartAutomated vs. SmartAutomated vs. Smart
Feature Automated Smart
Architecture I/O Based Networked
Communications One-way, Point-to-Point Two-way, Multi-Drop
Configuration Off-line On-line Download
Asset Management Proxy On-line Upload
Diagnostics Proxy Monitored in Real-time
Process Variables Single Multiple
Control Functions DCS or PLC Local Device
Component Cost $ $$$
Total Cost of Ownership $$$ $
Feature Partition ModelFeature Partition ModelFeature Partition ModelFeature Partition Model
Hybrid OHybrid O22 Sample System Sample SystemHybrid OHybrid O22 Sample System Sample System
Hybrid OHybrid O22 Sample System Realization Sample System RealizationHybrid OHybrid O22 Sample System Realization Sample System Realization
First, Drag and Drop Device from pick list
Then, set the network address and parameters
Add Devices to create a connection.
Some Final ThoughtsSome Final ThoughtsSome Final ThoughtsSome Final Thoughts