Small Tool Instruments and Data Management

Statistical Process Control•“DIGIMATIC” Mini-Processors•Signal Cables•Data transmission devices • Pages 4–19

Dial Gauges • Coating•Lever Gauges Thickness•Bore Gauges Gauges•Linear Gage• Pages 168–269

Measuring Tables • Levels•Dial Gauge Stands • Granite Plates•Bevel •Bevel Protractors • Pages 270–301

Gauge Blocks•Height Masters•Calibration instruments•

Pages 302–325

Vernier Calipers•Height Gauges•

Pages 108–167

Micrometers•Test Sets, Setting Rings•Threepoint Internal Micrometers•

Pages 20–107

3

Page 3: Small Tool Instruments - TECHMAR · 2011-10-17 · Small Tool Instruments and Data Management 5 Pages 8–9 Pages 10–11 “DIGIMATIC” Mini-Processors “MeasurLink®” Statistical

PRODUCTNEWS

U-WAVE®

Detailed information on page 18 up to 19.

USB Input ToolDetailed information on page 17.

ToleranzboxDetailed information on page 11.

Page 4: Small Tool Instruments - TECHMAR · 2011-10-17 · Small Tool Instruments and Data Management 5 Pages 8–9 Pages 10–11 “DIGIMATIC” Mini-Processors “MeasurLink®” Statistical

Small Tool Instruments and Data Management

55

Pages 8–9

Pages 10–11

“DIGIMATIC” Mini-Processors

“MeasurLink®” Statistical software

Signal cables

Toleranzbox

Pages 6–7

„DIGIMATIC“ Data transmitters

Page 13–17

U-WAVE®

Radio transmission

Page 18–19

USB Input Tool Direct

USB-signal cables

Page 12

Page 5: Small Tool Instruments - TECHMAR · 2011-10-17 · Small Tool Instruments and Data Management 5 Pages 8–9 Pages 10–11 “DIGIMATIC” Mini-Processors “MeasurLink®” Statistical

6

MeasurLink® – Total-Quality-ManagementsystemSupports and links all digital Mitutoyo measuring devices, from the hand-held measuring •device to the coordinate measuring machine.Allows integration of measuring data from analog measuring devices.•Also compatible with numerous measuring devices from other manufacturers.•Real-time display of the measuring situation, limitless recording, administration, assessment, •logging, documenting and tracing of measurement data.Linking of measuring devices exclusively at your own company as well as with those at •suppliers and customers.Comfortable, user-friendly operation.•

Real Time for hand-held measuring devicesSTAT Measure for stationary measuring devices

SPC workstation software•Recording of measuring data via the keypad or hand-held measuring devices•Assessment (individual features, overview) with editing function of the test reports•Variable screen layout•Representation of the work piece as image in the following formats: *.bmp, *.jpg, *.gif, *.dxf, •*.dwf, *.dwg •Integration of multimedia functions to support the testing process (video, sound) in these formats: *.avi, *.mpg, *.mpeg, *.mov, *.wav

Real Time Plus for hand-held measuring devicesSTAT Measure Plus for stationary measuring devices

•SPC workstation softwareRecording of measuring data via the keypad or hand-held measuring devices•Assessment (Individual feature, overview) with editing function of the test reports•Variable screen layout• •Representation of the workpiece as CAD model or image in the following formats: *.bmp, *.jpg, *.gif, *.dxf, *.dwf, *.dwgIntegration of multimedia functions to support the testing process (video, sound) in these •formats: *.avi, *.mpg, *.mpeg, *.mov, *.wavDisplay of single or multiple test features concurrently•Integration of “Hoops” CAD viewer for dynamic display of the CAD model in the *.hsf format•

Real Time Plus

STAT Measure

STAT Measure Plus

Pocket ML

Prozess- Analyzer

Measur.Net

Prozess- Manager

Gage R & R

Real Time

Gage Management

Page 6: Small Tool Instruments - TECHMAR · 2011-10-17 · Small Tool Instruments and Data Management 5 Pages 8–9 Pages 10–11 “DIGIMATIC” Mini-Processors “MeasurLink®” Statistical

7

Gage R & RSoftware for gage capability analysis

Determining the parameters•Repeatability, reproducibility and linearity•Creating test reports•

Process AnalyzerSoftware for short-term and long-term process analysis

Test cycle summaries•Creating reports•Tracing of corrective measures that were introduced•Importing and exporting of test data•

Process ManagerReal-time monitoring of ongoing test processes via the network (even where test stations •are spatially separated, for example, over the Internet)Programmable alarm function by means of optical or acoustic alarm notifications or via an •emailVariable design of the screen layout (control charts, histograms, hall plan, etc.)•

ML Gage ManagementTesting equipment management software

Site management•Calibration due date monitoring•Gauge capability study due date monitoring•Inspection schedule preparation and management•

Pocket MLSoftware Pocket MeasurLink (Language: German)

Interface cable for DIGIMATIC measuring devices•Pocket PC•

Please consult the product brochures for detailed information on these and other products.

Page 7: Small Tool Instruments - TECHMAR · 2011-10-17 · Small Tool Instruments and Data Management 5 Pages 8–9 Pages 10–11 “DIGIMATIC” Mini-Processors “MeasurLink®” Statistical

8

No. 264-504-5 D (DP-1 VR)

“DIGIMATIC” Mini Processor Type DP-1 VRMitutoyo‘s DP-1 VR is so compact, it fits right on your palm. But with this powerful little device •you can print data from calipers, micrometers and other measuring devices equipped with DIGIMATIC port and even perform statistical evaluations. Printing speed is excellent, too, easy accessible with a one-touch start and with the built in •thermal line printer there‘s almost no noise. The thermosensitive paper has outstanding durability and chemical resistance for long-term storage. The DP-1 VR even lets you transmit the data to a computer using an RS-232 C connecting cable.•Easy printing function•Excellent readability due to large character print•Clock function for loading measuring data•Processing Capacity for up to 9.999 data•

No. 937179 T

Example for application

Specifications

No. 264-504-5 D DP-1 VR

Printing method: Thermal line printerPrinting dot: 384 dot (8 dot / mm)Printing speed: 6,5 mm/s

(using AC adapter)Printing paper: 48 mPrinting line: ca. 6500 lines

for large characters ca. 12.000 lines for normal characters

Processing capacity: Mode 1/2/3: 9.999 data Mode 0: 100.000 dataPrinting data: Measurement data,

GO/±NG judgment, number of data, maximum/minimum value, range, average, standard deviation, number of defective, fraction defective, process capability index, histogram, D-chart, control chart generation for Xd-bar and control limit data, date and time

Output function: Output the measuring data (RS-232 C) or GO/±NG judgment

Input timer: 0,25 s; 1 s; 5 s; 30 s; 1 min; 30 min; 60 min (0.25 sec. only statistical function)

Power: AC adapter 6 V (no interchangeable to DP-1 HS) Electric battery: LR-6 (alkaline), Ni-MH (rechargeable, batteries are not charged in the device)

Battery life: 10 years (clock battery), 10,000 lines (1600 mA 1time/5 sec. using the nickel hydrofluoric battery)

Operating temerature: (using AC adapter): 0° to 45° C / (using battery): 10° to 45° C

Storage temperature: –10° to 50° C

Standard accessories

No. Designation09EAA119 D AC adapter09EAA069 D Printer paper (1 roll)

Optional accessories

No. Designation937179 T Footswitch09EAA084** RS-232 C-Signal cable 1 m (9-Pin)

for connection DP-1 VR to PC965516** GO/NG Cable*09EAA094 RS-232 C-Signal cable 1 m (25-Pin)

For DP-1 VR connection to display Glass scale KS/KC/KL/KLL/KA

Consumable Spares

No. Designation011037 LR-6 batteries (4 pieces)011348 NI-MH-batteries (rechargeable)09EAA082-5 Printer paper (5 rolls)

Dimensions in mm

Series 264

* For forwarding tolerance assessments to external systems. ** 09EAA084 and 965516 cannot be used simultaneously.

Page 8: Small Tool Instruments - TECHMAR · 2011-10-17 · Small Tool Instruments and Data Management 5 Pages 8–9 Pages 10–11 “DIGIMATIC” Mini-Processors “MeasurLink®” Statistical

9

Lower limit

Input data

Upper limit

Process capability index

Number of data

Average

Range

Number of devision of the histogram

Lower control limit (R control)

Upper control limit (R control)

Upper control limit (X_ control)

Lower control limit (X_ control)

“DIGIMATIC” Mini Processor Type DP-1 VR

Series 264

Key functions Key designation Mode 0 Mode 1, 2

CL Only measurement data clear. Press before setting limit. CE Cancel the previous measurement data.

TOL-LIMIT Press before entering or finish the upper/lower measurement mode. Cancel measurement mode.

STAT Do not operate Making histogram to printout the calculation result via statistical analysis

FEED Printer paper is fed when this key is pressedDATA Enter data via measuring devices

PRINTER ON/OFF Controls the printer’s ON/OFF statusPOWER Power ON/OFF

Mode 3Subgroup in measurement Subgroup after measurement

CL Reentering from data No. 1 Only measurement data clear.CE Cancel previous measurement data. Cancel previous subgroup.

TOL-LIMIT Exiting the measurement. Go to next subgroup measurement.STAT Finish the subgroup measurement.

Printout the X-R calculation result.Print out and calculate the control limit value from each subgroup to complete

FEED Printer paper is fed when this key is pressedDATA Enter data via measuring devices

PRINTER ON/OFF Controls the printer’s ON/OFF statusPOWER Power ON/OFF

Page 9: Small Tool Instruments - TECHMAR · 2011-10-17 · Small Tool Instruments and Data Management 5 Pages 8–9 Pages 10–11 “DIGIMATIC” Mini-Processors “MeasurLink®” Statistical

10

“DIGIMATIC” Signal CablesMitutoyo’s “DIGIMATIC”-format allows for connecting not only numerous additional devices, •such as printers, counters and the like, but also for connecting one or more “DIGIMATIC”-measuring instruments to an external PC employing a Mitutoyo transmitter.

“DIGIMATIC” measuring instruments require either of the following items for data transmission:1. Footswitch2. Data key on the transmitter (if present)3. Data key on the instrument (if present)4. Data request from the PC5. Signal cables with data key

(if connectable to the measuring instrument)Plug connectors to the measuring instruments

Plug connectors to the peripherals (DMX transmitters or data printers)

Order No. Port Application with Measurement instrumentsSignal cable plugs1 m 2 m

905338 905409 A DIGIMATIC Dial Indicator Type ID-S (Series 543) A DIGIMATIC Dial Indicator Type ID-C (Series 543) A DIGIMATIC Dial Indicator Type ID-U (Series 575) A DIGIMATIC Thickness gauge (Series 547) A DIGIMATIC Caliper (Series 500, 550, 551, 573 with the exception of IP-65/IP-66/IP-67 calipers) “DIGIMATIC” Karbon Caliper (Series 552) except IP-66 caliper“DIGIMATIC” Height gauge (Series 192, 570) A DIGIMATIC Depth gauge (Series 547) Portabel hardness testing devices (Series 811)A DIGIMATIC inside measuring device Bore Gage (Series 511)

Straight (without data key)

905689 905690 Back side (without data key)

905691 905692 Right (without data key)

905693 905694 Left (without data key)

959149 959150 A DIGIMATIC Depth gauge (Series 571) except IP-67 depth gauge “DIGIMATIC” Built-in Caliper (Series 572) except IP-66 built-in caliper“DIGIMATIC” Universal Bevel Protractor (Series 187)

with data key (not for Dial Indicators Type ID-S)

05CZA662 05CZA663

“DIGIMATIC” Micrometer (Series 293, 314, 317, 323, 324, 326, 331, 340, 342, 369, 389, 395, 422) “DIGIMATIC” Micrometer heads (Series 350) “DIGIMATIC” Depth micrometer (Series 329) “DIGIMATIC” Inside micrometer with jaws (Series 345)IP-65 Three-point inside micrometer “DIGIMATIC-Holtest” (Series 468)“DIGIMATIC” Inside micrometer (Series 337, 339)

with data key and screws

05CZA624 05CZA625 IP-65/IP-66/IP-67 A DIGIMATIC Caliper (Series 500, 550, 551, 573) IP-67 A DIGIMATIC Depth gauge (Series 571)IP-66 A DIGIMATIC Karbon Caliper (Series 552)IP-66 A DIGIMATIC Built-in Caliper (Series 572)

with data key and screws

21EAA194 21EAA190 A DIGIMATIC Dial Indicators Type ID-B / ID-N (Series 543) without data key

937387 965013 A Quick Micrometer (Series 227, 293, 342, 369, 422) “DIGIMATIC” Micrometers (Series 293-151-30 to 293-154-30, 293-571 to 293-578, 340-513 to 340-519) “DIGIMATIC” Micrometer heads (Series 164)“DIGIMATIC” Micrometer heads (Series 227) “DIGIMATIC” Standard micrometer (Series 121) A DIGIMATIC Borematic (Series 568) Height Micrometer “Heightmaster” (Series 515) Stationary hardness tester “Wizhard” (Series 810) Stationary hardness tester “Micro Vickers HM” (Series 810) Stationary hardness tester “Micro Vickers HV” (Series 810) Mobile hardness tester “HH 411” (Series 810)

6 Pins (without data key)

937386 965012 ATK Stationary hardness tester (Series 810) ARK Stationary hardness tester (Series 810)

10 Pins (without data key)

936937 965014 A DIGIMATIC Dial Indicator Type ID-F (Series 543) “DIGIMATIC” Dial Indicator Type ID-H (Series 543) Portable surface roughness tester SJ-201 P / S / PR (Series 178) Portable surface roughness tester SJ-301 / S / PR (Series 178) Portable surface roughness tester SJ-401 / SJ-402 (Series 178) Profile projector PJ-Series (Series 303) Profile projector PH-Series (Series 172) Height Micrometer “CERA-Heightmaster” (Series 515) Linear Height Gage “Linear Height” (Series 518) Height gauge QM-Height (Series 518) LINEAR GAGES Counter (Series 542) LSM-6000 Counter for Laser Scan Micrometer (Series 544) Laser-Scan Micrometer LSM 9506 (Series 544) “DIGIMATIC” Multi-unit (Series 572) “LITEMATIC” VL-50 (Series 318)

Identical connectors on both ends (without data key)

21JAA300D Dial Caliper Gauge „DIGI-TEST“ (for 209-531 bis 209-533) DIGIMATIC-Signal cable with Interface

011518 Dial Caliper Gauge „DIGI-TEST“ (for 209-570 bis 209-573) DIGIMATIC-Signal cable

All cable details refer to the products listed in the catalog.

Page 10: Small Tool Instruments - TECHMAR · 2011-10-17 · Small Tool Instruments and Data Management 5 Pages 8–9 Pages 10–11 “DIGIMATIC” Mini-Processors “MeasurLink®” Statistical

11

“DIGIMATIC” Extension Cables

No. 011393

DIGIMATIC measurement devices with data output

DIGIMATIC Transmitters or DIGIMATIC Miniprocessor

DIGIMATIC Signal cable to the measuring instruments 1 m or 2 m

DIGIMATIC Signal cable No. 936937 1 m No. 965014 2 m

No. 011391 5 m No. 011392 8 m No. 011393 10 m

Tolerance boxExternal Tolerane box

With security evaluates•Simple connection at DIGIMATIC measuring instument.•Simple representation of a tolerance evaluation - NG / property / + NG for•DIGIMATIC-measuring instrument.•Power over the adapter (standard of accessories) or 2 batteries LR6.•Tolerance setting over the measuring instrument.•

No. 011516

Standard accessories

No. Designation– Power aadapter

Optional accessories

No. Designation011037 Battery LR6

Length No. 5 m 011391 8 m 01139210 m 011393

Page 11: Small Tool Instruments - TECHMAR · 2011-10-17 · Small Tool Instruments and Data Management 5 Pages 8–9 Pages 10–11 “DIGIMATIC” Mini-Processors “MeasurLink®” Statistical

12

USB Input Tool Direct• Direct connection for hand-held measuring devices to a USB interface • Multi-channel input for measurement values, e.g. in Microsoft Excel• 7 different connector types for data output of the most diverse measuring devices • Software USB ITPAK to the transmission of measured values as text format (VCP)• Software USB ITPAK to the simple production of sheets in Excel• Compatibly to Windows 2000/XP/Vista/Windows 7

Sonderzubehör

No. Bezeichnung937179 T Footswitch06ADV384 USB-Connecting cable for the

connection of a foot switch06ADV386 Software USB-ITPAK with Dongle

USB

System is cascadeable.Commercial standard USB-

Hub for multi connector

Mitutoyo USB-ITPAK-Software

Foot switch over USB

AFB

C D E

G

No. Model Remark

06ADV380A A IP-protected Model with Data out switch

06ADV380B B IP-protected Model with Data out switch

06ADV380C C With Data out switch

06ADV380D D 10-pin, simple Model

06ADV380E E 6-pin, round Model

06ADV380F F Simple, straight model

06ADV380G G IP-protected for dial gages

Signal cable USB

Application Situation Software USB-ITPAK Data format

Arbitrary software, which expects a keyboard entry

1. Only a USB input tools signal line is needed

Software is not needed Measured value as keyboard format (HID=Human Interface Device)

commercial statistics software like e.g. Mitutoyo MeasurLink

2. Its needed a USB input tools signal cable and the software USB ITPAK

generated uniquely per measuring inst-rument (cable) a firmly assigned virtual COM-Port (VCP). Is inactive thereafter.

MUX-10 Spezification (e.g. 01A+138.626) with firm COM assignment as channel identification

Arbitrary software, which expects a keyboard entry e.g. Word, .txt-Format

- attached measuring instruments and foot switch are selected and assigned- determines the conclusion character- stores an expiration as Partprogram

Transmission of a measured value as text format (VCP=as virtually COM Port)

Excel - attached measuring instruments and footswitch are selected and assigned- the complete takes over organizati-on of the Exceltable, i.e. transferred measured values become in pre-defined goal cells written

Measuring report Excel-For-mat und Character sequence with max. 31 character (e.g. Textinput)

Advantages of the new Digimatic of USB connections

Technical dataInput: USB (HID / VCP)Cable length: 2m 160 mm (06ADV384)OS: Windows 2000, Vista, XP, Windows 7Max connectable devices Windows XP / 2000: 108 Devices (18 Hubs with 7 Ports and 1 Software Dongle)Windows Vista / 7: 20 Devices

Foot witch connection over USB

Page 12: Small Tool Instruments - TECHMAR · 2011-10-17 · Small Tool Instruments and Data Management 5 Pages 8–9 Pages 10–11 “DIGIMATIC” Mini-Processors “MeasurLink®” Statistical

13

“DIGIMATIC” USB interface

“DIGIMATIC” Data transmitter

The DMX–1 USB is a microcontrolled interface for connecting a measurement device with “DIGIMATIC” interface to an external computer featuring USB interface. The device reports as “virtual” RS-232 C interface to the computer.

DMX–1 USB

The DMX–1 seriell is a microcontrolled inter-face for connecting a measurement device with “DIGIMATIC” interface to an external computer featuring RS-232 C interface. The device works without external power supply (The handshake lines RTS and DTR are necessary for the power supply.).

DMX–1 serial

Measuring device interface for transmitting measured values from Mitutoyo measuring •instruments into appropriate application programs. The instrument communicates with the PC via a driver program generally included with the CAQ software. The application defines what measuring devices are to be read in, how often the measurement is to be repeated etc.

“DIGIMATIC” USB interface for connecting a “DIGIMATIC” measuring instrument to a PC-USB interface for direct reading into an application software such as Microsoft Excel.

No. 011506

No. 011216

No. 264-014-10

Interface parametersType DMX –1 seriellNo. 011216Data input: 1 x DIGIMATICData output: RS-232 C serial signalInterface cable connection: for serial cable D-SUB 9Footswitch connector: yesBaud rate: 9600 BaudData bits: 8Stop bits: 1Parity: none

Optional accessories

No. Designation011196 Connecting cable for computer

D-SUB 9 – D-SUB 9 (2 m)937179 T Footswitch

Interface parametersType DMX–1 USBNo. 011506Data input: 1 x DIGIMATICData output: USB serial signalInterface cable connection: for Mini USB cable

Standard 5-pinFootswitch connector: yesBaud rate: 9600 BaudData bits: 8Stop bits: 1Parity: none

Standard accessories

No. Designation– USB cable– Driver software

Optional accessories

No. Designation937179 T Footswitch

Interface parametersType DIGIMATIC USB interfaceNo. 264-014-10Data input: 1 x DIGIMATICData output: USB keypad signal (USB 2.0)Interface cable connection: USB cable, fixedFootswitch connector: yesOperation System: 98 SE / ME / 2000 / XP/ Vista

Standard accessories

No. Designation– USB cable attached to the device

Optional accessories

No. Designation937179 T Footswitch

Page 13: Small Tool Instruments - TECHMAR · 2011-10-17 · Small Tool Instruments and Data Management 5 Pages 8–9 Pages 10–11 “DIGIMATIC” Mini-Processors “MeasurLink®” Statistical

14

“DIGIMATIC” DMX-TransmittersMeasuring device interface for transmitting measured values from Mitutoyo measuring •instruments into appropriate application programs. The instrument communicates with the PC via a driver program generally included with the CAQ software. The application defines what measuring devices are to be read in, how often the measurement is to be repeated etc.

DMX–3The DMX–3 allows for connecting three measurement devices featuring “DIGIMATIC” interfaces to the RS-232 C interfaces. Power supply with AC/DC adapter (standard accessory).

If the device is connected via USB interface, it registers as a “virtual” RS-232 C interface with the computer.

DMX–2 USBThe DMX–2 USB is a microcontrolled interface for connecting two measurement devices with “DIGIMATIC” interface to the USB interface of a computer. The device reports, depending on setting as “virtual” RS-232 C interface or as keyboard to the computer.

DMX–2 SThe DMX–2 S is a microcontrolled interface for connecting two measurement devices with “DIGIMATIC” interface to the RS-232 C interface of a computer. The device works without external power supply (The handshake lines RTS and DTR are necessary for the power supply.) Data transfer can be initiated with footswitch and adapter for footswitch available as optional accessory.

No. 011466

Sample application with footswitch (optional accessory)

No. 011443

No. 011505

Back side

Interface parametersType DMX–2 seriellNo. 011466Data input: 2 x DIGIMATICData output: RS-232 C serial signalInterface cable connection: for serial cable D-SUB 25Footswitch connector: yesBaud rate: 9600 BaudData bits: 8Stop bits: 1Parity: none

Interface parametersType DMX–2 USBNo. 011443Data input: 2 x DIGIMATICData output: USB serial signal

USB keypad signal (switchable on the box)

Interface cable connection: for Mini USB cable,

standard 5-pinFootswitch connector: yesBaud rate: 9600 BaudData bits: 8Stop bits: 1Parity: none

Standard accessories

No. Designation– USB cable– Driver software

Optional accessories

No. Designation937179 T Footswitch

Interface parametersType DMX–3No. 011505Data input: 3 x DIGIMATICData output: USB serial signal

RS-232 C serial signalInterface cable connection: for serial cable D-SUB 9

for USB cable, type BFootswitch connector: yesBaud rate: 1200 / 9600 Baud

(adustable with jumper)Data bits: 8Stop bits: 1Parity: none

Standard accessories

No. Designation– USB cable– Driver software– AC/DC adapter

Optional accessories

No. Designation011196 Connecting cable for computer

D-SUB 9 – D-SUB 9 (2 m)937179 T Footswitch

Optional accessories

No. Designation011197 Connecting cable for computer

D-SUB 25 – D-SUB 9 (0,2 m)011119 Connecting cable for computer

D-SUB 25 – D-SUB 9 (2 m)I-1502067 Connecting cable for computer

D-SUB 25 – D-SUB 25 (2 m)937179 T Footswitch

Back side

Page 14: Small Tool Instruments - TECHMAR · 2011-10-17 · Small Tool Instruments and Data Management 5 Pages 8–9 Pages 10–11 “DIGIMATIC” Mini-Processors “MeasurLink®” Statistical

15

DMX–8/2; DMX–16The DMX–8/2 and DMX–16 are interfaces for connecting measurement devices featuring “DIGIMATIC” ports to the RS-232 C interface of an external computer. Power supply 220 V–240 V 50 Hz. For the Dial Indicator Series 575 is the necessary voltage supply and a ABS-zero-point-key are available.

No. 011318

“DIGIMATIC” DMX-Transmitters

DMX 4–2The DMX 4–2 is an interface that allows for connecting four “DIGIMATIC” measuring instruments and two measuring instruments with Multi-RS-232 Interface to a PC with RS-232 C Interface.The DMX 4–2 takes on the following functions: 1. Adaptation of the signal level of the measuring device to the requirements of the serial interface 2. Translation of the various measurement signals into a common format 3. Communication between measuring devices and PC (channel selection etc.)

DMX–16 CThe DMX–16 C features integrated microprocessors for data processing, thus enabling simultaneous input from all measurement instruments and increasing data processing speed. For the Dial indicators Series 575 integrated power supply and a ABS-ZERO key are made available.

No. 011255

No. 011319

Interface parametersType DMX 4–2No. 011319Data input: 4 x DIGIMATIC 2 x RS-232 CData output: RS-232 C serial signalInterface cable connection: for serial cable D-SUB 9Footswitch connector: yesBaud rate: 9600 BaudData bits: 8Stop bits: 1Parity: noneStandard accessories: Power cable

Optional accessories

No. Designation011196 Connecting cable for computer

D-SUB 9 – D-SUB 9 (2 m)937179 T Footswitch

RS-232 C connecting cable for DMX 4–2

No. Designation011338 Coating Thickness Gauge

DIGI DERM 1100/1200011339 KA Counter for linear scales011340 EF Counter for Linear Gauge

Probe, Laser Scan Micrometer, Linear Height Gauges LH-600

011341 Dial Caliper Gauge Series 209011342 Standard Opto RS-232011343 Sartorius MC1 balance011344 Mettler PM 3000 balance011345 Kern 510 balance011346 Heidenhain VRZ/ND

Incremental counter011387 Linear Height Gauges

QM-Height

Interface parametersType DMX–8/2No. 011318Data input: 8 x DIGIMATICData output: RS-232 C serial signalInterface cable connection: for serial cable D-SUB 9Footswitch connector: yesBaud rate: 9600 BaudData bits: 8Stop bits: 1Parity: noneStandard accessories: Power cable

Interface parametersType DMX–16No. 011191Number of input channels: 16As for DMX–8

Interface parametersType DMX–16 CNo. 011255As for DMX–16

Optional accessories

No. Designation011196 Connecting cable for computer

D-SUB 9 – D-SUB 9 (2 m)937179 T Footswitch

Page 15: Small Tool Instruments - TECHMAR · 2011-10-17 · Small Tool Instruments and Data Management 5 Pages 8–9 Pages 10–11 “DIGIMATIC” Mini-Processors “MeasurLink®” Statistical

16

“DIGIMATIC” DMX-Transmitters

No. 011192-1

DMX–3 T USBKeyboard interface The measurement converter DMX–3 T USB allows for connection of three “DIGIMATIC” measurement instruments to the keyboard interface of an IBM-compatible computer. Thus applications asking for manual input of measurement data only (such as spread sheet calculation, word processing) are being provided with the respective interface. After the operator initiates data transmission the DMX–3 T USB simulates the keyboard input from the measurement device. The keyboard remains operative.

“DIGIMATIC” Switch BoxThe measurement switch box allows for connecting up to five “DIGIMATIC” measurement •devices to a single “DIGIMATIC”-Data processor (e. g. DMX–1).

No. 011235

No. 011220-1

DMX–3 T/FS USBKeyboard interfaceSpecifications same as DMX–3 T USB, but the measured values can only be trigged via footswitches.The footswitch is available as a special accessory.

Back side

Back side

Interface parametersType DMX–3 T USBNo. 011192-1Number of input channels: 3Data output: USB keyboard /

PS2 keyboard

Standard accessories

DesignationKeyboard cable for PS2 keyboard Connection: USB cable for direct connection to PC-USB

Interface parametersType DMX–3 T/FS USBNo. 011220-1Number of input channels: 3Data output: USB keyboard /

PS2 keyboard

Optional accessories

No. Designation937179 T Footswitch

Standard accessories

DesignationKeyboard cable for PS2 keyboard Connection: USB cable for direct connection to PC-USB

Interface parametersType Switch boxNo. 011235Number of input channels: 5Data output: “DIGIMATIC”

Optional accessories

No. Designation936937 Signal cable (1 m)526688 D AC/DC adapter (9 V, 500 mA)937179 T Footswitch

Page 16: Small Tool Instruments - TECHMAR · 2011-10-17 · Small Tool Instruments and Data Management 5 Pages 8–9 Pages 10–11 “DIGIMATIC” Mini-Processors “MeasurLink®” Statistical

17

“DIGIMATIC” Transmitters DL-1000 / DL-1000 MThe “DIGIMATIC” DL-1000 / DL-1000 M are data logger for storing measurement data that •have been recorded by a “DIGIMATIC” measuring to be output to a computer. The measuring device is connected to the I/O port of the DL-1000 / DL-1000 M with a data cable •and the measurement data are being transferred with the data switch on the measuring device or the DL-1000 / DL-1000 M. For data transfer to the computer the devices are hooked up to an interface connection with •the computer. (See pages 11–14). Data transfer from the DL-1000 / DL-1000 M are being executed with the data or footswitch of •an interface or upon request from the respective software. With regards to the interfaces of the measurement devices the DL-1000 / DL-1000 M acts like a “DIGIMATIC” measurement instrument. Data can be output directly to a connected printer with “DIGIMATIC” interface.•

Type DL-1000 / DL-1000 M

No. 011264 / No. 011264 M

Specifications

Type DL-1000 No. 011264Type DL-1000 MNo. 011264 MDimensions: 120 x 60 x 26 mmMass: 130 g

Memory(DL-1000 / DL-1000 M): Up to 999 measure ment values can be stored by the data loggers. (DL-1000 M): Sample or feature related operation is possible. A maximum of 100 features from 9 samples can be loaded. If the number of features is reduced, the available number of samples is increased. Based on the number of features, the DL-1000 M will calculate automatically how many samples are available. If, e. g., you want to measure 10 features, you can choose a maximum of 99 samples.Data formatAll data are loaded or output in Mitutoyo “DIGIMATIC” compatible format.Connection to measuring instrumentsTo output measurement values, DL-1000 / DL-1000 M can be connected to any interface or protocol printer which allow for connecting Mitutoyo “DIGIMATIC” compatible measuring instruments.

Standard accessories:

Designation1 battery (9 V) block LithiumSignal cable 10 pole to 10 pole (0.25 m)

Optional accessories:

No. Designation936937 Signal cable (1 m)965014 Signal cable (2 m)

Keys and functionsDepending on the selected mode the keys of the Digi-Log enable the following functions:

Measuring mode Output modeTransfers the actual value at the cursor position to the Digi-Log. Same function as data switch on measuring device.

Transfer the displayed value of the Digi-Log to an interface or printer.

The DL-1000 / DL-1000 M is turned off after 4 sec.

The DL-1000 / DL-1000 M is turned off after 4 sec.

Scrolls the list of measured data up or down by one value.

Scrolls the list of measured data up or down by one value.

Scrolls the list of measured data up or down by 50 value.

Scrolls the list of measured data up or down by 50 value.

Switches to output mode. Switches to measurement mode.

Mode < Erase memory? >

No Yes

Mode < Erase memory? >

No YesSwitches to block creation (DL-1000 M only).

All measurement values starting with the current position are output in 0,6 sec cycles.

Not used. All measurement values starting with the current position are output in 1,1 sec cycles.

Page 17: Small Tool Instruments - TECHMAR · 2011-10-17 · Small Tool Instruments and Data Management 5 Pages 8–9 Pages 10–11 “DIGIMATIC” Mini-Processors “MeasurLink®” Statistical

18

U-WAVE®

Measurement Data Wireless Communication System up to 20 m.

The U-WAVE system enables easy wireless data communication from a measuring tool to a PC •using the Digimatic protocol. Measurement workability is improved by eliminating the long and cumbersome data cables usually required and the user-friendly interface allows data to be loaded into any software product that accepts keyboard input, such as Excel* or Notepad, sondern auch die Anbindung an unterschiedliche Statistikprogramme wie das Mitutoyo-eigene MeasurLink. Das alles erledigt U-WAVE auf extrem wirtschaftliche Weise: Rund 400.000 Datenüber tragungen leistet die CR 2032 Lithiumbatterie.

U-WAVE-T (Transmitter)IP-67-type U-WAVE-T has an IP-67-level dust/water-proof function. •This model can be used in combination with, for example, a coolant-proof caliper, micrometer or indicator.

Ill. Actual size

The buzzer model has a hole so that you can hear the sound.

U-WAVE-R (Receiver) U-WAVE-R-Receiver

Standard U-WAVEPAK setup software

Wall installation board

Technische Daten

Übertragungsreichweite: ca. 20 mModulation: DS - SS(Direct Sequence Spread Spectrum)Übertragungs-geschwindigkeit: 250 KbpsFrequenz: 2,4 GHz Band 15 Kanäle wählbar

Optional accessories

No. Designation02AZA200 Holder for U-Wave T (Transmit-

ter) Contents: Support plate, attachment volume, screws

02AZA200 Holder for Caliper, Micrometer and Dial Indicator.

Attachmentband

Screws

U-WAVE TLED rot bzw. grün zeigt an, ob der Messwert angekommen ist.

Consumable article

No. Designation05SAA217D Lithium battery CR 2032

Model U-WAVE-T (IP-67-Modell)

U-WAVE-T (Summer-Modell)

No. 02AZD730D 02AZD880DProtection Range IP-67 –Data reception indication LEDs (green / red) Summer und LEDs (green / red)Battery life ca. 400,000 transmittalsExternal dimensions 44 x 29,6 x 18,5 mmTransferfrequency 2,46 GHz band, 15 phase, 2,405 - 2,475 GHzWeight 23 g

Model U-WAVE-RNo. 02AZD810DPower supply Via USBNumber of U-Wave-R units that can be connected to one PC up to 16Number of U-Wave-T units that can be connected up to 100Length USB cable 1 mExternal dimensions 140 x 80 x 31,6 mmWeight 130 gSoftware U-WavePak

Page 18: Small Tool Instruments - TECHMAR · 2011-10-17 · Small Tool Instruments and Data Management 5 Pages 8–9 Pages 10–11 “DIGIMATIC” Mini-Processors “MeasurLink®” Statistical

19

U-WAVE-ConnectionA short cable is used to connect a measuring tool to its U-WAVE-T unit. Select the appropriate cable from A to G below (7 types) to suit the measuring tool.

Examples:

Quick Micrometer No. 02AZD790E

ABS DIGIMATIC Indicator ID-N No. 02AZD790G

DIGIMATIC Indicator ID-H No. 02AZD790D

DIGIMATIC Height Gage No. 02AZD790F

Clip use example(Standard accessories)

AFB

C D E

G

Super Caliper No. 02AZD790A

QuantuMike No. 02AZD790B

ABS DIGIMATIC Caliper No. 02AZD790C

02AZE140F Application with Footswitch connection

Standard accessories

No. Designation– Clip to the cable attachment– Screwdriver

Optional accessories

No. Designation937179T Footswitch

U-WAVE-T (Sender)U-WAVE-T (Sender)Anschlusskabel

Messgerät mit Digimatic-Ausgang

U-WAVE-T Connection cableWithout Footswitch connection

cable-length: 160 mm

Model No.without Footswitch connection

No.with Footswitch connection

Designation

A 02AZD790A 02AZE140A Water-proof model with output buttonB 02AZD790B 02AZE140B Water-proof model with output buttonC 02AZD790C 02AZE140C With data-out button typeD 02AZD790D 02AZE140D 10-pin plain typeE 02AZD790E 02AZE140E 6-pin roundF 02AZD790F 02AZE140F Plain type straightG 02AZD790G 02AZE140G Plain type straight water-proof model