REFERENCE STANDARDS DESIGN 1. AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, 5TH EDITION, 2010. 2. AASHTO LRFD CONSTRUCTION SPECIFICATIONS, 3RD EDITION, 2010. 3. MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES - ASCE/SEI 7-10. 4. INTERNATIONAL BUILDING CODE, 2009 EDITION. 5. FHWA-NHI-10-024 DESIGN AND CONSTRUCTION OF MECHANICALLY STABILIZED EARTH WALLS AND REINFORCED SOIL SLOPES - VOLUME I. 6. FHWA-NHI-10-025 DESIGN AND CONSTRUCTION OF MECHANICALLY STABILIZED EARTH WALLS AND REINFORCED SOIL SLOPES - VOLUME II. SOILS 1. AASHTO M 145 - AASHTO SOIL CLASSIFICATION SYSTEM. 2. AASHTO T 104 - STANDARD METHOD OF TEST FOR SOUNDNESS OF AGGREGATE BY USE OF SODIUM SULFATE OR MAGNESIUM SULFATE. 3. AASHTO T 267 - STANDARD METHOD OF TEST FOR DETERMINATION OF ORGANIC CONTENT IN SOILS BY LOSS OF IGNITION. 4. ASTM C33 - STANDARD SPECIFICATION FOR CONCRETE AGGREGATES. 5. ASTM D422 - STANDARD TEST METHOD FOR PARTICLE-SIZE ANALYSIS OF SOILS. 6. ASTM D448 - STANDARD CLASSIFICATION FOR SIZES OF AGGREGATES FOR ROAD AND BRIDGE CONSTRUCTION. 7. ASTM D698 - STANDARD TEST METHOD FOR LABORATORY COMPACTION CHARACTERISTICS OF SOIL USING STANDARD EFFORT. (12,400 FT-LBF/FT (2,700 KN-M/M)). 8. ASTM D1241 - STANDARD SPECIFICATION FOR MATERIALS FOR SOIL-AGGREGATE SUBBASE, BASE AND SURFACE COURSES. 9. ASTM D1556 - STANDARD TEST METHOD FOR DENSITY AND UNIT WEIGHT OF SOIL IN PLACE BY SAND-CONE METHOD. 10. ASTM D1557 - STANDARD TEST METHOD FOR LABORATORY COMPACTION CHARACTERISTICS OF SOIL USING MODIFIED EFFORT. (56,000 FT-LBF/FT (2,700 KN-M/M)). 11. ASTM D2487 - STANDARD PRACTICE FOR CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES (UNIFIED SOIL CLASSIFICATION SYSTEM). 12. ASTM D2488 - STANDARD PRACTICE FOR DESCRIPTION AND IDENTIFICATION OF SOILS (VISUAL-MANUAL PROCEDURE). 13. ASTM D3080 - STANDARD TEST METHOD FOR DIRECT SHEAR TEST OF SOILS UNDER CONSOLIDATED DRAINED CONDITIONS. 14. ASTM D4254 - STANDARD TEST METHOD FOR MINIMUM INDEX DENSITY AND UNIT WEIGHT OF SOILS AND CALCULATION OF RELATIVE DENSITY. 15. ASTM D4318 - STANDARD TEST METHOD FOR LIQUID LIMIT, PLASTIC LIMIT, AND PLASTICITY INDEX OF SOILS. 16. ASTM D4767- TEST METHOD FOR CONSOLIDATED-UNDRAINED TRIAXIAL COMPRESSION TEST FOR COHESIVE SOILS. 17. ASTM D4972 - STANDARD TEST METHOD FOR PH OF SOILS. 18. ASTM D6938 - STANDARD TEST METHOD FOR IN-PLACE DENSITY AND WATER CONTENT OF SOIL AND AGGREGATE BY NUCLEAR METHODS (SHALLOW DEPTH). 19. ASTM G51 - STANDARD TEST METHOD FOR MEASURING PH OF SOIL FOR USE IN CORROSION TESTING. 20. ASTM G57 - STANDARD TEST METHOD FOR FIELD MEASUREMENT OF SOIL RESISTIVITY USING THE WENNER FOUR-ELECTRODE METHOD. DRAINAGE PIPE 1. ASTM D3034 - STANDARD SPECIFICATION FOR TYPE PSM POLY (VINYL CHLORIDE) (PVC) SEWER PIPE AND FITTINGS. 2. ASTM F2648 - STANDARD SPECIFICATION FOR 2 TO 60 INCH [50 TO 1500 MM] ANNULAR CORRUGATED PROFILE WALL POLYETHYLENE (PE) PIPE AND FITTINGS FOR LAND DRAINAGE APPLICATIONS. 3. ASTM D2412 - STANDARD TEST METHOD FOR DETERMINATION OF EXTERNAL LOADING CHARACTERISTICS OF PLASTIC PIPE BY PARALLEL-PLATE LOADING TITLE SHEET Date: Project No.: Sheet No.: WESTWOOD NORTHERN BLVD LANDSLIDE REMEDIATION CINCINNATI, OHIO 08-11-20 20-061 3760 Fulton Grove Road, Cincinnati, Ohio 45245 Office (513) 752-9500 Website: www.civilsolutionsassociates.com Designed By: Checked By: Scale: By Description Date No. REVISIONS EP JRB AS SHOWN CINCINNATI METROPOLITAN HOUSING AUTHORITY WESTWOOD NORTHERN BOULEVARD CINCINNATI, OHIO Slope Reconstruction Plans For: SHEET DESCRIPTION 1.0 Title Sheet 2.0 - 2.1 Specifications 3.0 Plan View 4.0 - 4.1 Cross Section 5.0 Typical Details S-1.0 PROJECT LOCATION Jeffrey Barrow (Oct 29, 2020 15:11 EDT) Jeffrey Barrow

Upload: others

Post on 28-Jan-2021

7 views

Category:

Documents


0 download

TRANSCRIPT

  • REFERENCE STANDARDS

    DESIGN

    1. AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, 5TH EDITION, 2010.

    2. AASHTO LRFD CONSTRUCTION SPECIFICATIONS, 3RD EDITION, 2010.

    3. MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES - ASCE/SEI 7-10.

    4. INTERNATIONAL BUILDING CODE, 2009 EDITION.

    5. FHWA-NHI-10-024 DESIGN AND CONSTRUCTION OF MECHANICALLY STABILIZED EARTH WALLS AND

    REINFORCED SOIL SLOPES - VOLUME I.

    6. FHWA-NHI-10-025 DESIGN AND CONSTRUCTION OF MECHANICALLY STABILIZED EARTH WALLS AND

    REINFORCED SOIL SLOPES - VOLUME II.

    SOILS

    1. AASHTO M 145 - AASHTO SOIL CLASSIFICATION SYSTEM.

    2. AASHTO T 104 - STANDARD METHOD OF TEST FOR SOUNDNESS OF AGGREGATE BY USE OF SODIUM SULFATE

    OR MAGNESIUM SULFATE.

    3. AASHTO T 267 - STANDARD METHOD OF TEST FOR DETERMINATION OF ORGANIC CONTENT IN SOILS BY LOSS

    OF IGNITION.

    4. ASTM C33 - STANDARD SPECIFICATION FOR CONCRETE AGGREGATES.

    5. ASTM D422 - STANDARD TEST METHOD FOR PARTICLE-SIZE ANALYSIS OF SOILS.

    6. ASTM D448 - STANDARD CLASSIFICATION FOR SIZES OF AGGREGATES FOR ROAD AND BRIDGE CONSTRUCTION.

    7. ASTM D698 - STANDARD TEST METHOD FOR LABORATORY COMPACTION CHARACTERISTICS OF SOIL USING

    STANDARD EFFORT. (12,400 FT-LBF/FT (2,700 KN-M/M)).

    8. ASTM D1241 - STANDARD SPECIFICATION FOR MATERIALS FOR SOIL-AGGREGATE SUBBASE, BASE AND

    SURFACE COURSES.

    9. ASTM D1556 - STANDARD TEST METHOD FOR DENSITY AND UNIT WEIGHT OF SOIL IN PLACE BY SAND-CONE

    METHOD.

    10. ASTM D1557 - STANDARD TEST METHOD FOR LABORATORY COMPACTION CHARACTERISTICS OF SOIL USING

    MODIFIED EFFORT. (56,000 FT-LBF/FT (2,700 KN-M/M)).

    11. ASTM D2487 - STANDARD PRACTICE FOR CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES (UNIFIED

    SOIL CLASSIFICATION SYSTEM).

    12. ASTM D2488 - STANDARD PRACTICE FOR DESCRIPTION AND IDENTIFICATION OF SOILS (VISUAL-MANUAL

    PROCEDURE).

    13. ASTM D3080 - STANDARD TEST METHOD FOR DIRECT SHEAR TEST OF SOILS UNDER CONSOLIDATED DRAINED

    CONDITIONS.

    14. ASTM D4254 - STANDARD TEST METHOD FOR MINIMUM INDEX DENSITY AND UNIT WEIGHT OF SOILS AND

    CALCULATION OF RELATIVE DENSITY.

    15. ASTM D4318 - STANDARD TEST METHOD FOR LIQUID LIMIT, PLASTIC LIMIT, AND PLASTICITY INDEX OF SOILS.

    16. ASTM D4767- TEST METHOD FOR CONSOLIDATED-UNDRAINED TRIAXIAL COMPRESSION TEST FOR COHESIVE

    SOILS.

    17. ASTM D4972 - STANDARD TEST METHOD FOR PH OF SOILS.

    18. ASTM D6938 - STANDARD TEST METHOD FOR IN-PLACE DENSITY AND WATER CONTENT OF SOIL AND

    AGGREGATE BY NUCLEAR METHODS (SHALLOW DEPTH).

    19. ASTM G51 - STANDARD TEST METHOD FOR MEASURING PH OF SOIL FOR USE IN CORROSION TESTING.

    20. ASTM G57 - STANDARD TEST METHOD FOR FIELD MEASUREMENT OF SOIL RESISTIVITY USING THE WENNER

    FOUR-ELECTRODE METHOD.

    DRAINAGE PIPE

    1. ASTM D3034 - STANDARD SPECIFICATION FOR TYPE PSM POLY (VINYL CHLORIDE) (PVC) SEWER PIPE AND

    FITTINGS.

    2. ASTM F2648 - STANDARD SPECIFICATION FOR 2 TO 60 INCH [50 TO 1500 MM] ANNULAR CORRUGATED PROFILE

    WALL POLYETHYLENE (PE) PIPE AND FITTINGS FOR LAND DRAINAGE APPLICATIONS.

    3. ASTM D2412 - STANDARD TEST METHOD FOR DETERMINATION OF EXTERNAL LOADING CHARACTERISTICS OF

    PLASTIC PIPE BY PARALLEL-PLATE LOADING

    TITLE SHEET

    Date:

    Project No.:

    Sheet No.:

    WESTWOOD NORTHERN BLVD

    LANDSLIDE REMEDIATION

    CINCINNATI, OHIO

    08-11-20

    20-061

    3760 Fulton Grove Road, Cincinnati, Ohio 45245

    Office (513) 752-9500 Website: www.civilsolutionsassociates.com

    Designed By:

    Checked By:

    Scale:

    ByDescriptionDateNo.

    REVISIONS

    EP

    JRB

    AS SHOWN

    CINCINNATI METROPOLITAN

    HOUSING AUTHORITY

    WESTWOOD NORTHERN BOULEVARD

    CINCINNATI, OHIO

    Slope Reconstruction Plans For:

    SHEET DESCRIPTION

    1.0 Title Sheet

    2.0 - 2.1 Specifications

    3.0 Plan View

    4.0 - 4.1 Cross Section

    5.0 Typical Details

    S-1.0

    PROJECT LOCATION

    Jeffrey Barrow (Oct 29, 2020 15:11 EDT)Jeffrey Barrow

    https://na2.documents.adobe.com/verifier?tx=CBJCHBCAABAAxL6ee7D5DyVlCwk6ielHM0DZ6g0BLlzvhttps://na2.documents.adobe.com/verifier?tx=CBJCHBCAABAAxL6ee7D5DyVlCwk6ielHM0DZ6g0BLlzv

  • CONSTRUCTION AND INSPECTION REQUIREMENTS

    1.0 GENERAL

    1.1 CONSTRUCTION INSPECTION OF THE COMPACTED SOIL BENCHING SHALL BE PERFORMED BY THE OWNER'S

    DESIGNATED INSPECTION ENGINEER. THE INSPECTION ENGINEER SHALL BE A LICENSED PROFESSIONAL

    ENGINEER AND EMPLOYED BY A GEOTECHNICAL ENGINEERING FIRM DULY LICENSED AND AUTHORIZED TO

    PRACTICE WITHIN THE STATE OF OHIO.

    1.2 THE INDIVIDUAL(S) DESIGNATED AS THE ON-SITE INSPECTOR SHALL BE AN EMPLOYEE OF THE SAME

    GEOTECHNICAL ENGINEERING FIRM AS THE INSPECTION ENGINEER. THE ON-SITE INSPECTOR SHALL HAVE

    ADEQUATE KNOWLEDGE OF THE PROJECT, GENERAL KNOWLEDGE OF THE LOCAL GEOLOGY AND BE

    FAMILIAR WITH THE PROJECT CONSTRUCTION PLANS AS WELL AS THE ACCEPTED MEANS AND METHODS OF

    EARTHWORK CONSTRUCTION.

    1.3 THE INSPECTION ENGINEER SHALL SUPERVISE AND DIRECT THE ACTIVITIES OF THE ON-SITE INSPECTOR.

    2.0 MATERIALS

    2.1 FOUNDATION SOIL - KEYWAY BENCH

    2.1.1 ASSUMPTIONS HAVE BEEN MADE REGARDING THE SHEAR STRENGTH OF FOUNDATION SOIL. THE

    EFFECTIVE SHEAR STRENGTH PARAMETERS OF THE FOUNDATION SOIL ASSUMED FOR THE DESIGN ARE AS

    FOLLOWS:

    2.1.2 PRIOR TO CONSTRUCTION OF THE BENCHES, THE INSPECTION ENGINEER SHALL INSPECT THE

    CONDITIONS OF THE NATIVE SOILS TO VERIFY THAT THE ASSUMED SHEAR STRENGTH PARAMETERS FOR

    THE FOUNDATION SOILS ARE ADEQUATELY CONSERVATIVE. IF THE INSPECTION ENGINEER'S OPINIONS

    BASED UPON THIS INITIAL OBSERVATION DO NO CONCUR WITH THE DESIGN PARAMETERS LISTED IN 2.1.1,

    THE INSPECTION ENGINEER SHALL NOT ALLOW WORK TO COMMENCE IN THE AREAS IN QUESTION UNTIL

    SUCH TIME THAT THE SITE CONDITIONS ARE CONSISTENT WITH THE DESIGN PARAMETERS ASSUMED IN 2.1.1.

    2.2 COMPACTED SOIL

    2.2.1 FILL SOIL PLACED IN THE BENCHES SHALL EXHIBIT MINIMUM SHEAR STRENGTH PARAMETERS LISTED

    FOR THE CLAY SOIL BELOW.

    2.3 DRAINAGE FILL SHALL BE A DURABLE, CRUSHED STONE MEETING THE REQUIREMENTS OF AASHTO M43 FOR

    #57 AND THE FOLLOWING GRADATION:

    SIEVE SIZE % PASSING

    1-1/2 INCH 100

    1 INCH 95-100

    1/2 INCH 25-60

    NO. 4 0-10

    NO. 8 0-5

    2.4 COLLECTION DRAIN SYSTEM

    2.4.1 COLLECTION DRAIN PIPE SHALL BE 6-INCH DIAMETER, 3-HOLE PERFORATED/SLOTTED HDPE OR PVC

    PIPE WITH A SMOOTH INTERIOR AND A MINIMUM PIPE STIFFNESS OF 22 PSI PER ASTM D2412.

    2.4.2 ALL COLLECTION DRAINS SHALL BE WRAPPED IN GEOTEXTILE FABRIC.

    2.4.3 COLLECTION DRAIN PIPES, OUTLET PIPES AND FITTINGS SHALL ALL BE MADE BY THE SAME

    MANUFACTURER. OUTLET PIPES SHALL BE FURNISHED WITHOUT PERFORATIONS/SLOTS.

    3.0 EXCAVATION AND FOUNDATION PREPARATION

    3.1 THE CONTRACTOR SHALL EXCAVATE TO THE LINES AND GRADES SHOWN ON THE CONSTRUCTION

    DRAWINGS. EXCAVATIONS SHALL CONFORM TO OSHA REQUIREMENTS FOR SAFE EXCAVATIONS.

    3.2 EXCAVATIONS SHALL BE BENCH-CUT AS DIRECTED BY THE INSPECTION ENGINEER.

    3.3 THE COST OF OVER-EXCAVATION AND REPLACEMENT WITH MATERIAL MEETING THE APPROVAL OF THE

    INSPECTION ENGINEER SHALL BE AS QUANTIFIED BY THE INSPECTION ENGINEER AND AS DIRECTED BY THE

    OWNER'S WRITTEN CONTRACT CHANGE ORDER. DISTURBANCE OF SOIL OTHERWISE OUTSIDE THE LIMITS OF

    REQUIRED EXCAVATION SHALL BE AVOIDED.

    3.4 BEFORE CONSTRUCTION BEGINS, THE CONTRACTOR SHALL CLEAR AND GRUB TO THE REQUIRED LIMITS OF

    THE PROPOSED CONSTRUCTION ZONE AND REMOVE TOPSOIL, BRUSH, FROZEN SOIL, AND ORGANIC

    MATERIAL.

    3.5 THE INSPECTION ENGINEER SHALL ASSESS THE SUITABILITY OF THE FIRST BENCH AND DETERMINE IF IT IS

    ADEQUATE FOR THE PROPOSED CONSTRUCTION. IF THE INSPECTION ENGINEER'S ASSESSMENT INDICATES

    THAT THE FOUNDATION SOILS ARE INADEQUATE TO SUPPORT THE CONSTRUCTION OF THE PROPOSED

    BENCHES, THE INSPECTION ENGINEER SHALL NOT ALLOW WORK TO COMMENCE IN THE AREAS IN QUESTION

    UNTIL CIVIL SOLUTIONS CAN BE CONTACTED AND AN APPROPRIATE COURSE OF ACTION FOR THE

    IMPROVEMENT OF THE FOUNDATION SOIL CAN BE DETERMINED.

    Date:

    Project No.:

    Sheet No.:

    WESTWOOD NORTHERN BLVD

    LANDSLIDE REMEDIATION

    CINCINNATI, OHIO

    08-11-20

    20-061

    3760 Fulton Grove Road, Cincinnati, Ohio 45245

    Office (513) 752-9500 Website: www.civilsolutionsassociates.com

    Designed By:

    Checked By:

    Scale:

    ByDescriptionDateNo.

    REVISIONS

    EP

    JRB

    SPECIFICATIONS

    AS SHOWN

    S-2.0

    Jeffrey Barrow (Oct 29, 2020 15:11 EDT)Jeffrey Barrow

    https://na2.documents.adobe.com/verifier?tx=CBJCHBCAABAAxL6ee7D5DyVlCwk6ielHM0DZ6g0BLlzvhttps://na2.documents.adobe.com/verifier?tx=CBJCHBCAABAAxL6ee7D5DyVlCwk6ielHM0DZ6g0BLlzv

  • 4.0 SOIL COMPACTION AND INSPECTION

    4.1 THE INSPECTION ENGINEER SHALL INSPECT AND DOCUMENT ANY PLACEMENT AND COMPACTION OF SOIL IN

    THE BENCHED ZONE IN ACCORDANCE WITH THESE REQUIREMENTS. INSPECTION RECORDS SHALL

    DOCUMENT THE FOLLOWING:

    THE REQUIRED MINIMUM DRY UNIT WEIGHT PASS/FAIL ASSESSMENT

    ACTUAL DRY UNIT WEIGHT TEST LOCATION (STATION)

    ALLOWABLE MOISTURE CONTENT TEST ELEVATION

    ACTUAL MOISTURE CONTENT

    4.2 COMPACTION DENSITY AND MOISTURE CONTENT REQUIREMENTS - SOIL PLACED IN THE BENCHED ZONE

    SHALL BE COMPACTED IN ACCORDANCE WITH THE FOLLOWING:

    7.2.1 COMPACT BACKFILL TO WITHIN 98 PERCENT OF MAXIMUM DRY DENSITY AND WITHIN 2 PERCENT OF ITS

    OPTIMUM MOISTURE CONTENT AS MEASURED IN ACCORDANCE WITH ASTM D698 (STANDARD PROCTOR

    METHOD).

    4.3 ALL GRANULAR OR SOIL FILL MATERIALS SHALL BE INSTALLED IN COMPACTED LIFTS NO GREATER THAN 10

    INCHES AND NO LESS THAN 6 INCHES.

    4.4 SELF-PROPELLED COMPACTION EQUIPMENT OR ANY OTHER HEAVY CONSTRUCTION EQUIPMENT SHALL NOT

    BE OPERATED WITHIN 5 FEET OF THE EXISTING PIER WALL

    4.5 WITHIN 5 FEET OF THE EXISTING PIER WALL, ONLY HAND-OPERATED (I.E. WALK-BEHIND) COMPACTION

    EQUIPMENT MAY BE USED.

    5.0 DRAINAGE AND EROSION PROTECTION

    5.1 AT THE END OF EACH WORK DAY, THE CONTRACTOR SHALL GRADE THE SURFACE OF THE LAST LIFT OF SOIL

    AND COMPACT.

    5.2 DURING SITE CONSTRUCTION, THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF THE CUT

    AGAINST SURFACE WATER AT ALL TIMES BY THE USE OF BERMS, DIVERSION DITCHES, TEMPORARY DRAINS,

    AND ANY OTHER MEANS NECESSARY. AT NO TIME SHALL SURFACE WATER BE PERMITTED TO POND WITHIN

    THE CUT AREA. AT NO TIME SHALL SURFACE WATER BE PERMITTED TO FLOW ALONG OR TOWARD THE CUT.

    5.3 ALL SLOPES SHALL BE VEGETATED AND PROTECTED FROM EROSION AS SOON AS POSSIBLE FOLLOWING

    THEIR CONSTRUCTION.

    6.0 INSPECTION ENGINEER REQUIREMENTS

    6.1 THE INSPECTION ENGINEER SHALL INSPECT CONSTRUCTION OF THE BENCHES FOR CONFORMANCE WITH

    THESE CONSTRUCTION DRAWINGS AND THESE CONSTRUCTION REQUIREMENTS.

    6.2 THE INSPECTION ENGINEER SHALL CONFIRM THAT THE SOIL PROPERTIES RECOMMENDED AND ASSUMED

    FOR THIS DESIGN ARE ADEQUATELY CONSERVATIVE.

    6.3 INSPECTION SHALL INCLUDE SOIL EVALUATION, FILL PLACEMENT AND COMPACTION.

    6.4 THE INSPECTION ENGINEER SHALL NOTIFY THE CONTRACTOR OF ANY DEFICIENCIES AND ALLOW THE

    CONTRACTOR A REASONABLE OPPORTUNITY TO REPAIR ANY DEFECT BEFORE REPORTING THE DEFICIENCY

    IN WRITING TO THE OWNER.

    6.5 THE INSPECTION ENGINEER SHALL DOCUMENT ALL INSPECTION OBSERVATIONS AND FIELD QUALITY

    CONTROL TEST RESULTS.

    6.6 THE INSPECTION ENGINEER IS RESPONSIBLE FOR READING AND UNDERSTANDING THESE DRAWINGS AND

    REQUIREMENTS.

    Date:

    Project No.:

    Sheet No.:

    WESTWOOD NORTHERN BLVD

    LANDSLIDE REMEDIATION

    CINCINNATI, OHIO

    08-11-20

    20-061

    3760 Fulton Grove Road, Cincinnati, Ohio 45245

    Office (513) 752-9500 Website: www.civilsolutionsassociates.com

    Designed By:

    Checked By:

    Scale:

    ByDescriptionDateNo.

    REVISIONS

    EP

    JRB

    SPECIFICATIONS

    AS SHOWN

    S-2.1

    Jeffrey Barrow (Oct 29, 2020 15:11 EDT)Jeffrey Barrow

    https://na2.documents.adobe.com/verifier?tx=CBJCHBCAABAAxL6ee7D5DyVlCwk6ielHM0DZ6g0BLlzvhttps://na2.documents.adobe.com/verifier?tx=CBJCHBCAABAAxL6ee7D5DyVlCwk6ielHM0DZ6g0BLlzv

  • A

    '

    A

    200.0'

    250.0'

    190.0'

    B

    '

    B

    Date:

    Project No.:

    Sheet No.:

    WESTWOOD NORTHERN BLVD

    LANDSLIDE REMEDIATION

    CINCINNATI, OHIO

    08-11-20

    20-061

    3760 Fulton Grove Road, Cincinnati, Ohio 45245

    Office (513) 752-9500 Website: www.civilsolutionsassociates.com

    Designed By:

    Checked By:

    Scale:

    ByDescriptionDateNo.

    REVISIONS

    EP

    JRB

    GENERAL NOTES:

    1. THE ABOVE SITE LAYOUT HAS BEEN DEVELOPED FROM THE

    CINCINNATI AREA GEOGRAPHIC INFORMATION SYSTEM, CAGIS.

    NO TOPOGRAPHIC SURVEY HAS BEEN COMPLETED AT THIS

    TIME.

    BENCHING SITE PLAN

    1

    BENCHING SITE PLAN

    AS SHOWN

    SCALE: 1:50

    S-3.0

    EXISTING PIERS

    (UPSLOPE)

    DISTURBANCE LIMIT OF BENCHING

    CLEAR VEGETATION FOR

    EQUIPMENT ACCESS

    BENCHES TIE INTO EXISTING SLOPE

    CLEAR VEGETATION FOR

    EQUIPMENT ACCESS

    BENCHES TIE INTO EXISTING SLOPE

    Jeffrey Barrow (Oct 29, 2020 15:11 EDT)Jeffrey Barrow

    https://na2.documents.adobe.com/verifier?tx=CBJCHBCAABAAxL6ee7D5DyVlCwk6ielHM0DZ6g0BLlzvhttps://na2.documents.adobe.com/verifier?tx=CBJCHBCAABAAxL6ee7D5DyVlCwk6ielHM0DZ6g0BLlzv

  • Minimum 1% Slope

    Minimum 1% Slope

    Minimum1% Slope

    Minimum1% Slope

    Minimum1% Slope

    Minimum1% Slope

    Minimum1% Slope

    Minimum1% Slope

    Minimum1% Slope

    #57 Stone Surrounding 6" P

    erf. Plastic Drain

    Wrapped in Geotextile Fab

    ric and Outlet Every 50'

    Through the Face of the Slo

    pe

    Anticipated

    Top of Rock

    Proposed Grade

    Existing Grade

    ExistingPier

    0 10 20 30 40 50 60 70

    615

    605

    595

    585

    575

    565

    555

    80 90 100 110 120 130 140 150 160 170 180 190 200 210

    645

    650

    640

    635

    630

    625

    620

    610

    600

    590

    580

    570

    560

    220 230 240

    WestwoodNorthern

    BlvdBeyond

    15.0'

    15.0'

    10.0'

    10.0'

    10.0'

    10.0'

    10.0'

    10.0'

    10.0'

    5.0'

    Minimum1% Slope

    10.0'

    Minimum1% Slope

    10.0'

    Minimum1% Slope

    10.0'

    Minimum1% Slope

    10.0'

    Minimum1% Slope

    10.0'

    Minimum1% Slope

    10.0'

    Minimum 1% Slope15.0'

    5.0'

    Minimum1% Slope

    10.0'

    5.0'

    5.0'

    5.0'

    5.0'

    5.0'

    5.0'

    5.0'

    5.0'

    5.0'

    5.0'

    5.0'

    5.0'

    5.0'

    5.0'

    5.0'

    4.0'

    550

    Blanket Drain - Min. 1.0 Foot

    #57 Stone In Bottom Two

    Benches

    Outlet Slope Drains Thro

    ugh Face

    of Slope to Proposed Swa

    le

    Proposed Swale

    Date:

    Project No.:

    Sheet No.:

    WESTWOOD NORTHERN BLVD

    LANDSLIDE REMEDIATION

    CINCINNATI, OHIO

    08-11-20

    20-061

    3760 Fulton Grove Road, Cincinnati, Ohio 45245

    Office (513) 752-9500 Website: www.civilsolutionsassociates.com

    Designed By:

    Checked By:

    Scale:

    ByDescriptionDateNo.

    REVISIONS

    EP

    JRB

    TYPICAL CROSS SECTION

    AS SHOWN

    S-4.0

    SCALE: 1" = 16'

    CROSS-SECTION A-A'

    2

    1. KEYWAY BENCH SHOULD EXPOSE WEATHERED OR UNWEATHERED

    SHALE AND LIMESTONE BEDROCK.

    2. BENCHES SLOPE BACK INTO THE HILLSIDE AT A 1% GRADE.

    3. BENCH EXCAVATIONS SHALL BE MADE IN ACCORDANCE WITH OSHA GUIDELINES.

    4. BENCHES SHOWN ABOVE ARE FOR REFERENCE ONLY - ACTUAL BENCH DIMENSIONS SHALL BE

    DETERMINED IN THE FIELD DURING EXCAVATION OPERATIONS.

    COSTRUCTION NOTES:

    Jeffrey Barrow (Oct 29, 2020 15:11 EDT)Jeffrey Barrow

    https://na2.documents.adobe.com/verifier?tx=CBJCHBCAABAAxL6ee7D5DyVlCwk6ielHM0DZ6g0BLlzvhttps://na2.documents.adobe.com/verifier?tx=CBJCHBCAABAAxL6ee7D5DyVlCwk6ielHM0DZ6g0BLlzv

  • 0 10 20 30 40 50 60 70

    615

    605

    595

    585

    575

    565

    555

    80 90 100 110 120 130 140 150 160 170 180 190 200 210

    645

    650

    640

    635

    630

    625

    620

    610

    600

    590

    580

    570

    560

    220 230 240 250

    550

    Benches Tie Into Existing Gra

    de

    at Outer Limits of Repair

    (Lengh and Width of Bench

    es

    Vary per Field Condition

    s)

    Bench & Compact Repair Spa

    ce

    per OSHA Excavation G

    uidelines

    Benches Tie Into Existing Gra

    de

    at Outer Limits of Repair

    (Lengh and Width of Bench

    es

    Vary per Field Condition

    s)

    Date:

    Project No.:

    Sheet No.:

    WESTWOOD NORTHERN BLVD

    LANDSLIDE REMEDIATION

    CINCINNATI, OHIO

    08-11-20

    20-061

    3760 Fulton Grove Road, Cincinnati, Ohio 45245

    Office (513) 752-9500 Website: www.civilsolutionsassociates.com

    Designed By:

    Checked By:

    Scale:

    ByDescriptionDateNo.

    REVISIONS

    EP

    JRB

    TYPICAL CROSS SECTION

    AS SHOWN

    S-4.1

    SCALE: 1" = 16'

    CROSS-SECTION B-B'

    3

    1. KEYWAY BENCH SHOULD EXPOSE WEATHERED OR UNWEATHERED

    SHALE AND LIMESTONE BEDROCK.

    2. BENCHES SLOPE BACK INTO THE HILLSIDE AT A 1% GRADE.

    3. BENCH EXCAVATIONS SHALL BE MADE IN ACCORDANCE WITH OSHA GUIDELINES.

    4. BENCHES SHOWN ABOVE ARE FOR REFERENCE ONLY - ACTUAL BENCH DIMENSIONS SHALL BE

    DETERMINED IN THE FIELD DURING EXCAVATION OPERATIONS.

    COSTRUCTION NOTES:

    Jeffrey Barrow (Oct 29, 2020 15:11 EDT)Jeffrey Barrow

    https://na2.documents.adobe.com/verifier?tx=CBJCHBCAABAAxL6ee7D5DyVlCwk6ielHM0DZ6g0BLlzvhttps://na2.documents.adobe.com/verifier?tx=CBJCHBCAABAAxL6ee7D5DyVlCwk6ielHM0DZ6g0BLlzv

  • 1.00

    1.00

    6" PVC SCH. 40

    #57 CRUSHED

    STONE

    WRAP IN GEOTEXTILE

    DAYLIGHT SLOPE DRAINS TO

    PROPOSED DRAINAGE SWALE

    STRUCTURES HAVE

    BEEN REMOVED

    APPROXIMATE AREA

    OF BENCHING

    Date:

    Project No.:

    Sheet No.:

    WESTWOOD NORTHERN BLVD

    LANDSLIDE REMEDIATION

    CINCINNATI, OHIO

    08-11-20

    20-061

    3760 Fulton Grove Road, Cincinnati, Ohio 45245

    Office (513) 752-9500 Website: www.civilsolutionsassociates.com

    Designed By:

    Checked By:

    Scale:

    ByDescriptionDateNo.

    REVISIONS

    EP

    JRB

    DRAINAGE DETAILS

    AS SHOWN

    S-5.0

    DRAINAGE PIPE DETAIL

    SCALE: 1" = 1'

    4

    DRAINAGE PLAN

    SCALE: 1" = 1'

    5

    Jeffrey Barrow (Oct 29, 2020 15:11 EDT)Jeffrey Barrow

    https://na2.documents.adobe.com/verifier?tx=CBJCHBCAABAAxL6ee7D5DyVlCwk6ielHM0DZ6g0BLlzvhttps://na2.documents.adobe.com/verifier?tx=CBJCHBCAABAAxL6ee7D5DyVlCwk6ielHM0DZ6g0BLlzv

  • 20-061 Slope Reconstruction Drawings - Aug11- KRFinal Audit Report 2020-10-29

    Created: 2020-10-29

    By: Karla Morales ([email protected])

    Status: Signed

    Transaction ID: CBJCHBCAABAAxL6ee7D5DyVlCwk6ielHM0DZ6g0BLlzv

    "20-061 Slope Reconstruction Drawings - Aug11 - KR" HistoryDocument created by Karla Morales ([email protected])2020-10-29 - 6:07:56 PM GMT- IP address: 74.215.13.53

    Document emailed to Jeffrey Barrow ([email protected]) for signature2020-10-29 - 6:08:37 PM GMT

    Email viewed by Jeffrey Barrow ([email protected])2020-10-29 - 7:10:44 PM GMT- IP address: 74.215.13.53

    Document e-signed by Jeffrey Barrow ([email protected])Signature Date: 2020-10-29 - 7:11:56 PM GMT - Time Source: server- IP address: 74.215.13.53

    Agreement completed.2020-10-29 - 7:11:56 PM GMT

    2020-10-29T12:11:58-0700Agreement certified by Adobe Sign