The DAP (Data Acquisition Panel) is designed to be a standalone acquisition panel that provides field maintenance personnel with a means of functionally testing and troubleshooting the ComboLog-SM used in field operations. The DAP can acquire and process data from the various ComboLog in time. It connects to a laptop running test software, it can be used with the ComboLog-SM in wireline mode.

Data Acquisition Panel (DAP)

IntroductionApplicationsTest and maintain the ComboLog-SMcalibration Real-time data acquisition and control in wireline mode

PHYSICAL DIMENSIONS and WEIGHTSHeight 8.75 in. (22.23 cm)Depth 25.2 in. (64 cm)Width 19 in. (48.26 cm)Weight 40 lbs. (18.14 kg)ENVIRONMENTAL CHARACTERISTICSOperating Temperature 32°F to 131°F (0°C to 55°C)Storage Temperature -58°F to 149°F (-50°C to 65°C)

POWERMaximum AC Power 240VacMinimum AC Power 100 Vac

Specifications

www.RenheSun.comwww.geovista.cn

The MCB is designed to operate as:1. A battery condition tester2. A universal interface box for programming and downloading data from TSO-M.The box interfaces laptop running Windows XP (or upper) with ComboLog tools.The MCB contains an auto battery depassivator that, on connection to the MCB, detects when a battery is unable to supply enough power and switches in the depassivating circuit. When the battery has finished depassivating, the depassivating circuit automatically switches off.On the front of the unit there is a LCD display where you can monitor tool power. Tool power can also be monitored on the PC screen when the tool is running in monitor mode.

IntroductionApplications

Memory Control Box (MCB)

Portable and easily moved between PC’sLogging battery status and conditioningToolstring power monitoringBattery depassivator indicatorBattery voltage OK/LOW indicatorTool power & PC control indicatorsProgram the TSO-SM and downloading data from TSO-SM

MCB TYPICAL CONFIGURATION

www.RenheSun.comwww.geovista.cn

Slim Combo Logging System with Memory (ComboLog-SM)

General SpecificationsMax Temperature 350°F (175°C)Max Pressure 20000 psi (137.9 MPa)Tool Diameter 2.875 in. (73 mm)Minimum Hole Diameter 4 in. (304.8 mm)Maximum Hole Diameter 12 in. (406 mm)Power Requirements:Battery Lithium battery 10 cells 36 Vdc (Nominal)Sampling Rate 5 samples per secondMemory Capacity 2 GB

DOWNHOLE TOOLS Temperature/Tension/Mud Resistivity Tool-Slim (TTR-S) 1.56mCasing Collar Locator-Slim (CCL-S) 0.57mDigital Transmission/Spetralog/ Orientation Tool-Slim memory (TSO-SM) 2.75mCompensated Neutron Tool-Slim Memory (CNT-SM) 2mLitho-Density Logging Tool-Slim Memory (ZDT-SM) 2.79mDecentralizer Caliper-Slim Memory (DCC-SM) 2.09mAcoustic Tool-Slim Memory (ACT-SM) 5.13mDual Lateral log Tool-Slim Memory (DLT-SM) 5.83mShallow Focused Laterolog-Slim Memory (SFL-SM) 2.5mArray Induction Tool-Slim Memory (AIT-SM) 7.75mFour Arms Caliper-Slim Memory (FAC-SM) 3.4mBattery Power Sub (BPS) 2mMass Isolator Sub-Slim (MIS-S) 3.88mInsulation Sub-Slim (ISS-S) 0.53mSwivel Sub-Slim (SWS-S) 1.29mFour Arms Centralizer Sub-S (FCS-S) 1.56mFlex Joint Sub-Slim (FJS-S) 1.23mDecentralizer Sub-Slim (DCS-S) 2.09mOptional tools:Double Knuckle Joint -Slim (DKJ-S) 1.56mSingle Knuckle Joint -Slim (SKJ-S) 0.96mPressure Isolated Sub (PIS) 0.58m

ApplicationsIn-situ formation resistivity (Rt) with array inductionFormation evaluation and lithology identificationBorehole geometry

������������������������������������������� �Weight����� T�������������������������������������������������������� ���������� ����������

Introduction

www.RenheSun.comwww.geovista.cn

The ComboLog-SM delivers the same, high-quality data you would expect to get from conventional tools, but with a much smaller 2.875-in. diameter in hostile envirement. Every Slim Combo logging tool is fully characterized, which means that you never have to choose between data fidelity and tool size. These tools provide the accuracy of traditional wireline logging. The Slim combo Logging system offers multiple conveyance options. Data can be acquired in real time when run on wireline, or it can be deployed by coiled tubing or drillpipe in memory mode. When it conveyed by drillpipe, it can be released by mechanical ball method or Timing control method.With Slim Combo logging services, you can easily achieve reliable logging in challenging applications with data quality you expect from conventional tools.OurSlim Combo logging tools are available for holes with diameters up to 12 in. Theyare environmentally corrected and fully characterized for:

www.geovista.cn

Slim Combo Logging System with Memory (ComboLog-SM)

www.RenheSun.com

SFL-SM

DLT-SM

AIT-SM

ACT-SM

FCS-S

ZDT-SM

DCC-SM

FJS-S

CNT-SM

TTR-S

CCL-S

SWS-S

ISS-S

Mechanical Releaser

Timing SwitchControl

Releaserr

Upper Hanger

Lower Hanger

Adjuster Sub-1

Adjuster Sub-2

FAC-SM

DCS-S

BPS

TSO-SM

DT S

Hanger & Releaser Equipment

Name

Upper Hanger

Adjuster Sub

Protective Casing

Lower Hanger

MechanicalReleaser

Timing ControlReleaser

MaximumOD

5.12 in.130.00 mm

5.12 in.130.00 mm

5.12 in.130.00 mm

5.12 in.130.00 mm

3.27 in. 83 mm

3.27 in. 83 mm

MinimumOD

4.72 in.120.00 mm

4.72 in.120.00 mm

4.72 in.120.00 mm

4.72 in.120.00 mm

-

-

Length

6 ft.-6.14 in.1.68 m

4 ft.-1.21 in.1.25 m

Select according to the toolstring

13 ft.-1.52 in.4.26 m

6 ft.-6.74 in.2 m

6 ft.-6.74 in.2 m

Specifications

Release type 1.Mechanical release by dropping the steel ball and pumping 2.Timing control release

Upper Hanger

Lower Hanger

www.RenheSun.comwww.geovista.cn

Mechanical Releaser

Timing SwitchControl Releaser

The TTR-S is a 2.75 in. diameter sub containing three types of transducers for measurement of cablehead tension/compression force, borehole temperature, and mud resistivity.

Introduction

www.RenheSun.comwww.geovista.cn

ApplicationsDetect and measure borehole temperature mud resistivity (Rm), and external cablehead tension and compression forces at the top of the tool string

Temperature/Tension/Mud Resistivity Tool-Slim (TTR-S)

SpecificationsMaximum Temperature 350°F (175°C)Maximum Pressure 20,000 psi (137.9 MPa)Tool Diameter 2.75 in. (70 mm) Minimum Hole Diameter 3.5 in. (89 mm)Maximum Hole Diameter N/AMake-up Length 5 ft.-1.3 in. (1.56 m)Shipping Length 6 ft.-4.28 in. (1.94 m)Weight 45.2 lbs (20.5 kg)Maximum Logging Speed 100 ft/min (30 m/min)Measurement RangeCablehead Tension 0 to 12,000 lbs Tension 0 to 10,000 lbs CompressionBorehole Temperature 32°F to 450°F (0°C to 230°C)Mud Resistivity 0.01 ohmm to 10 ohmmAbsolute AccuracyCablehead Tension ± 800 lbs Tension ± 5% * ± 800 lbs Compression ± 5% *Differential Cablehead Tension ± 100 lbs Tension ± 100 lbsCompressionBorehole Temperature ± 4°F ± 5% (2°C ± 5%)Mud Resistivity 0.01 ohmm ± 5%* The absolute accuracy is limited because of effects of pressure, temperature, and measurementelectronics. Therefore the TTR-S should only be used as a differential CHT device.RepeatabilityCablehead tension ± 100 lbs Tension ± 100 lbs CompressionBorehole Temperature ± 2°CMud Resistivity ± 0.01 ohmmWireline Requirements 7 conductor cableMaximum Tensile Force 50,000 lbf.Maximum Compressive Force 18,000 lbf.

The CCL-S Tool measurement is based upon the principle that a changing magnetic flux within the tool sensor coil generates a voltage across the terminals of that sensor coil. The magnetic field of a CCL-S magnet is affected by any magnetically sensitive material close to it, such as the casing in a borehole. A collar or joint in the casing changes the magnetic flux field including the flux passing through the sensor coil ends adjacent to the magnets,causing an electric voltage to be generated.

Introduction

www.RenheSun.comwww.geovista.cn

ApplicationsDepth Measurement

Casing Collar Locator-Slim (CCL-S)

SpecificationsMaximum Temperature 430oF (220oC)Maximum Pressure 25,000 psi (172.4 MPa)Tool Diameter 2.75 in. (70 mm)Minimum Hole Diameter 3.5 in. (89 mm)Maximum Hole Diameter 12.0 in. (305 mm)Make-up length 1 ft.-10.42 in. (0.57 m) Shipping length 3 ft.-1.38 in. (0.95 m)Weight 20 lbs. (9.1 kg) Source Type MagnetsSensor Type CoilMaximum Tensile Force 100,000 lbf. Maximum Compressive Force 100,000 lbf.

This tool is the downhole telemetry interface for GTS type tool. The primary function of the TSO-SM is to act as a repeater of the telemetry channels and to create the GTS tool Bus (GTS-IB).A secondary function is to acquire data from several sensors located in its electronic cartridge and outside of it. It can acquire the signal of natural gamma-ray spectralog, three orthogonal accelerometers and magnetometers, it can acquire the data from the downhole temperature/tension/mud resistivity.

IntroductionApplicationsData control

Lithology identification

Determination the clay type and clay content

Measuring bed thickness

Locating uranium by-porduct buildup in a cased well

Identifying potential fracture zones

Borehole orientation

* GTS: Geovista Telemetry System

Digital Transmission/Spetralog/ Orientation Tool-Slim memory (TSO-SM)

SpecificationsMaximum Temperature 350oF (175oC) Maximum Pressure 20,000 psi (137.9 MPa)Tool Diameter 2.875 in. (73 mm)Minimum Hole Diameter 4 in. (101.6 mm)Maximum Hole Diameter 12.0 in. (305 mm)Make-up Length 9 ft.-0.12 in. (2.75 m)Shipping Length 10 ft. -3.08 in. (3.13 m)Weight 75.85 lbs. (34.4 kg) Maximum Tensile Force 100,000 lbf.Maximum Compressive Force 100,000 lbf.Maximum Logging Speed 30 ft/min (9 m/min)Measuring Range 0.04 to 3.5 MTypical Oil Well K, U, Th concentrations. Potassium 0 to 20% Uranium 0 to 300 ppm Thorium 0 to 300 ppmMaximum Measureable Quantity Gamma Ray 2500 API Potassium 100 percent Uranium 250 ppm Thorium 700 ppmAccuracy GR: ±3% of measured value K, U, & Th: ±4% of measured value (accuracy compares measured values with true values)Precision for standard shale at 10 ft/min (3 m/min) GR: 100 ± 1.5 API K: 2 ± 0.15 percent U: 6 ± 0.51 ppm Th: 12 ± 1.03 ppm at 30 ft/min (9 m/min) GR: 100 ± 2.6 API K: 2 ± 0.26 percent U: 6 ± 0.88 ppm Th: 12 ± 1.78 ppmGamma Ray Energy Range 0.06 to 3.5 MeVNumber of Energy Channels 256Measure Point 1 ft – 1.7 in.(448mm)from bottom of sub Orientation:Sensor Accuracy Azimuth ± 1.5 degrees Deviation ± 0.25 degreesDrift Azimuth Deviation range 9° to 90° DAZ ± 1.5 degrees Deviation range 5° to 9° DAZ ± 6.0 degrees Deviation range 1° to 5° DAZ ± 10.0 degreesMeasure Point 5 ft – 1.42 in. (1560mm)from bottom of subCablehead Tension (TTR-S):Measurement Range from -53379 N (-12000 lbf) (-5436 kgf)Measurement Range to +53779 N (+12000 lbf) (+5346 kgf)Resolution 13.34 N (3 lbf) (1.359 kgf)Borehole Temperature (TTR-S):Measurement Range -55° C (-67° F) to +230° C (446° F)Resolution 0.12° C (0.216° F)Mud Resistivity (TTR-S):Measurement Range 0.01 ohm-m to 10 ohm-mResolution 0.00244 ohm-mPower Requirements: 36 VDC

www.RenheSun.comwww.geovista.cn

The CNT-SM measures the hydrogen index of downhole formations. The measurements are converted to porosity values, which in combination with density tool measurements provide an indication of lithology and gas in zones of interest.The CNT-SM contains a radioactive source that bombards the formation with fast neutrons. The neutrons are slowed, primarily by hydrogen atoms in the formation. Detectors count the slowed neutrons deflected back to the tool. Because the CNT-SM responds primarily to the hydrogen content of the formation, the measurements are scaled in porosity units. The CNT-SM uses two thermal detectors to produce a borehole-compensated thermal neutron measurement.

Introduction

www.RenheSun.comwww.geovista.cn

ApplicationsIndicate formation porosity in open or cased boreholes.

Dividing reservoir.

Distinguish gas reservoir.

Temperature/Tension/Mud Resistivity Tool-Slim memory (CNT-SM)

SpecificationsMaximum Temperature 350°F(175°C) Maximum Pressure 20,000 psi (137.9 MPa)Tool Diameter 2.875 in. (73 mm)Minimum Hole Diameter 4 in. (101.6 mm)Maximum Hole Diameter 12 in. (305 mm) (limited by decentralizer)Make-up Length 6 ft. - 6.74 in. (2 m)Shipping Length 7 ft. - 9.70 in. (2.38 m)Weight 106.26 lbs (48.2 kg)Maximum Logging Speed 60 ft/min (18 m/min)Typical Logging Speed 30 ft/min (9 m/min)Measuring Range -3 to 70 Limestone Porosity Units (p.u.)* Accuracy ± 0.5 p.u. below 7 p.u. porosity ± 7% of recorded value above 7 p.u. porosity* Repeatability ±1.5 p.u. @ 15% Limestone porosityDepth of Investigation 12 in. (304.8 mm), estimated for a 7.88-in. (200.0 mm) water-filled borehole with nominal 15% porosity formationVertical Resolution 28 in. (711.2 mm) given proper formation contrast above and below zone of interestMeasure Point Short Spacing 1 ft. - 10.23 in. (564.7 mm) Long Spacing 2 ft. - 2.97in. (685.2 mm) (both measurements are from the bottom of tool)Tension 100,000 lbf.Compression 44,500 lbf.

*Applies to a decentralized tool in a smooth 7.88 inch (200.0 mm) water-filled borehole.Operating Voltage and Currentat Cablehead 36 VDC Detector or Sensor Type He-3 tubeSource Type Am 241-Be9Source Strength 18curie - 4.5 MeV Neutrons

The ZDT-SM measures formation density, photoelectric factor (a lithology indicator), borehole diameter with Decentralizer Sub(DCS-S). The density data are used to calculate porosity and determine the lithology. The combination of density and CNT-S data is used to indicate the presence of gas.The ZDT-SM has a gamma ray source and two detectors.Magnetics shielding and high-speed electronics ensure excellent measurement stability. It records the full-pulse-height gamma ray spectra from both detectors and processes them into windows. Bulk density and photoelectric factor are derived conventionally from the windows counts with enhanced quality control.

Introduction

www.RenheSun.comwww.geovista.cn

ApplicationsPorosity determination

Lithology analysis and identification of minerals

Gas detection

Hydrocarbon density determination

Shaly sand interpretation

Rock mechanical properties calculations

Litho-Density Logging Tool-Slim memory (ZDT-SM)

SpecificationsMaximum Temperature: 350°F (175°C) Maximum Pressure 20,000 psi (137.9 Mpa)Tool Diameter 2.875 in. (73 mm)Minimum Hole Diameter 4 in. (101.6 mm)Maximum Hole Diameter 12 in. (305 mm) (limited by decentralizer)Make-up Length 9 ft.-1.84 in. (2.79 m) ZDT-SM EA 4 ft.- 7.12 in. (1.4 m) ZDT-SM MA 4 ft.-6.64 in. (1.39 m)Weight 153 lbs (69.3 kg) ZDT-SM EA 56 lbs (25.4 kg) ZDT-SM MA 96.78 lbs (43.9 kg)Maximum Logging Speed: 60 ft./min (18 m/min)Recommended Logging Speed <30 ft./min (9 m/min)Measuring Range 1.3 - 3.0 g/ccRepeatability: Den ±0.015 gm/cc (from 2 to 3 gm/cc) Pe ±0.2B/e (absence of mudcake)Absolute Accuracy: Den ±0.025 gm/cc (2.0 to 3.0 gm/cc) Pe ±0.3B/e (1.3 to 6.0 B/e)Depth of Investigation (50%) 1.5 in.Vertical Resolution 5.5 in. (14cm) given proper formation contrast above and below Zone of interestMeasure Point: Short Spacing 1 ft.-2.38 in. (365.4mm) Long Spacing 1 ft.-5.72 in. (450.2mm)Operating Voltage & Current 36 VDC Detector or Sensor Type ScintillationSourceType Cs 137 Source Strength 2 CurieMaximum Tensile Load 28,000 lbf.Maximum Compression Load 26,500 lbf.

gy ty

he of

cs nt thric ed

SpecificationsMaximum Temperature 350°F (175°C)Maximum Pressure 20,000 psi (137.9 MPa)Tool Diameter 2.875 in. (73 mm) max.Minimum Hole Size 4 in. (101.6 mm)Maximum Hole Diamet 12.0 in. (305 mm)Make up Length ACT-SM-EA 7 ft.-10.48 in. (2.4 m) ACT-SM-MA 8 ft.-11.3 in.(2.73 m)Total Weight ACT-SM-EA 66.8 lbs(30.3 kg), Estimated ACT-SM-MA 133.16 lbs (49.7 kg)Logging Speed 60 ft/min (18 m/min) max.Absolute Accuracy +/- .5 microsecondsRepeatability +/- 1 %Vertical Resolution 0.5 ft. (15.24 cm) Basic measurementPower Requirements 36 VDC Tensile Strength EA:49,000 lbf. MA:12,000 lbf.Compressional Strength EA:44,500 lbf. MA:3,000 lbf. Telemetry Standard GTSModes: Command mode 2Tool Tables mode 2Tool Status mode 2Data Mode 5 or Mode 7Transducer Type Receiver(s) Type Piezoelectric (monopole) Bandwidth Wideband (1-25 kHz) Number 4 Spacing 6.0 in. (152 mm) Offset 3.0 ft. (914 mm) min 6.5 ft. (1.98 m) max. Transmitter(s) Type Piezoelectric (monopole) Bandwidth Broadband (2-18 KHz) Number 2 Spacing 2 ft. (0.6 m)

ACT-SM primary application for this service is measurement of ����������������� ���� ����� !��� �"����� � ��� ���" �� �#�� $����������������������������������!��������������������"����������a relatively small physical tool package. The ACT-SM-EA is GTS compatible and simultaneously acquires up to 4 waveforms from up to 4 receivers. It is responsible for the data acquisition, downhole analysis, and telemetry interface for the ACT Tool. The ACT-SM-MA is the portion of the GTS Digital Acoustilog sonde which excites, receives and routes the acoustic signatures recovered by the tool.

Introduction

www.RenheSun.comwww.geovista.cn

Applications����������������!�������

Cement Bond Logging (CBL) and Variable density logging (VDL)

Acoustic Tool- Slim Memory (ACT-SM)

The DLT-SM tool measures formation resistivity and is designed primarily for use in boreholes filled with highly conductive drilling fluids. DLT-SM provides two resistivity measurements: a Shallow reading to investigate the formation near the borehole and a Deep reading to measure farther out where the formation is less disturbed by drilling fluids. These two readings are used to estimate the amount of hydrocarbon in a formation and the ease of recovering that hydrocarbon.

Introduction

www.RenheSun.comwww.geovista.cn

ApplicationsFor high temperature and high pressure environment

Measure the resistivity

Dual Lateral log Tool-Slim (DLT-SM)

SpecificationsMaximum Temperature 350°F (175°C) Maximum Pressure 20,000 psi (137.9 MPa) Tool Diameter 2.875in (73 mm)Minimum Hole Diameter 4 in (101.6 mm) Maximum Hole Diameter 12.0 in (305 mm) Make-up Length:(Electronics & Mandrel only) 19 ft. - 1.53 in. (5.83 m) EA 7 ft.-2.62 in. (2.2 m) MA 11 ft.-10.73 in. (3.63 m)Shipping Length: EA 8 ft.-5.58 in. (2.58 m) MA 13 ft.-1.68 in.(4.005 m)Weight: EA 118.6 lbs. (53.8 kg) MA 129.8 lbs.(58.9kg)Maximum Tensile Force 42,000 lbs Maximum Compressive Force 7,400 lbsDetector or Sensor Type Electrode Array (Mandrel & tool Housings) Maximum Logging Speed 60 ft/min (18.3 m/min) ������������'��#�� ;�=����>;?;;;�[\��Mud Type/Range Water based mud ,�;�;]^�[\�����_�;�[\��`�������� �����;�=����=;;;����\��{���������|^}����;�;~�[\���� �������=;;;����>;;;;�[\��{���������|^}����;�;=^�[\��Stability (at Max. Temp.) 5% of computed readings Vertical Resolution 2 ft (.61 m), given proper formation contrasts above and below zone of interest Radius of Investigation Deep Standard Return Mode(SrtnDp)55 in (1.397 m) Shallow Standard 18 in. (0.457 m) Measure Point 6 ft. – 0.83 in (1.85m) above matching point of black block of DLT-SM. Power Requirements 36 VDC Telemetry Protocol GTS

Introduction

www.RenheSun.comwww.geovista.cn

Applications

Shallow Focused Laterolog-Slim Memory (SFL-SM)

SpecificationsMaximum Temperature 350°F (175°C)Maximum Pressure 20,000 psi (137.9 MPa)Tool Diameter 2.875 in. (73 mm)Minimum Hole Diameter 4 in. (101.6 mm)Maximum Hole Diameter 15 in. (381.0 mm) nominal valueMake-up Length 8 ft.- 2.43 in. (2.5 m)Maximum Tensile Strength 20,000 lbf. (9000 kg)Maximum Compressional Strength 20,000 lbf. (9000 kg)Weight 209 lbs (95 kg)Maximum Logging Speed 110 ft/min (33.5 m/min)Curves Recorded:Curves Computed Curves AvailableCFOC: Conductivity from Focused Log RFOC: Resistivity from CFOC RIIM: Resistivity from CIIM RILD: Resistivity from CILDMeasuring Range CFOC: 0.5 to 5000 mmhoSensitivity Approx. 1 mV/mmho for Induction and Focused LogAccuracy ±2 mmho or ±3% of reading, whichever is greaterStability ±10 mmho at small signals or ±5% at large(Max.Temp.) signals (interval zero and calibrate set at max.temp.)Reliability 98% with proper preventive maintenanceRadius of Investigation:FOC 9.5 in. (24.1 cm) for Rt/RM=100FOC 13.0 in. (33.0 cm) for Rt/Rm=10Vertical Bed Resolution Refer to Log Interpretation Chart BookZero Point 1.67 ft (0.508 m) above bottom of toolWireline Requirements 7 conductor cableDetector of Sensor Type Electrodes

The tool provides the conductivity data necessary to estimate the effects of mud filtrate invasion and to resolve true formation resistivity. measurement recorded: Shallow Focused Laterolog

Detect and measure thin permeable beds in highly resistive formations

To aid in the interpretation of invasion profiles.

The Array Induction Tool-Slim Memory (AIT-SM) uses multi-spacing and multi-frequency measurements to acquire a complete set of data fromthe formations surrounding the borehole.The multi-spacing measurements allow improved conductivity measurements in complex environments. The short-spacing measurements (as short as 6-inch spacing) allow improved correction for borehole, rugosity and invasion effects. The long-spacing measurements (up to 94-inch spacing) are useful in deep invasion situations. The multiple-frequency measurements allow for an improved skin-effect correction and data quality checking. AIT-SM allows us to characterize invasion profiles, even in oil-based muds.

IntroductionApplicationsReservoir delineation

Determination of Rt

Determination of Sw Hydrocarbon identification and imaging

Determination of movable hydrocarbons Invasion profiling Thin-bed analysis

Array Induction Tool-Slim Memory (AIT-SM)

SpecificationsMaximum Temperature 350°F (175°C) Maximum Pressure 20,000 psi (137.9 MPa)Tool Diameter 2.875 in. (73 mm)Minimum Hole Diameter 4 in. (101.6 mm)Maximum Hole Diameter 20.0 in. (508 mm) Make-up Length (s) Mandrel 18 ft.-10.38 in. (5.75 m) Electronics 6 ft. - 6.74 in. (2 m) Total 25 ft. - 5.12 in. (7.75 m)Weight(s) Mandrel 192.90 lbs. (87.5 kg) Electronics 86.20 lbs. (39.1 kg)Logging Speed(S) Recommended 30 ft./min Maximum 60 ft./min at 4 samples per ft. 100 ft./min at 2 samples per ftFocused Conductivities Apparent Vertical Resolution 1 ,2 , 4 ft.Depth(s) of Investigation 10, 20, 30, 60, 90, 120 in. Measurement Range 0.1 to 2,000 ohm-m Measurement Accuracy (homogenous formation) 60, 90, 120 in. depth of investigation ±1 mS/m, ±2% of reading 30 in. depth of investigation ±2 mS/m, ±2% of reading 20 in. depth of investigation ±4 mS/m, ±2% of reading 10 in. depth of investigation ±10 mS/m, ±2% of readingSample Rate(S) 4 samples per ft. (recommended) 2 samples per ft. (high speed) Power Requirements:Operating Voltage & Current 36 VDCTensile Strength 50,000 lbf. (22686.8kgf)Compressive Strength 5200 lbf. (in 14-in. hole) (2359.4kgf) 6080 lbf. (in 12 1/4-in. hole) (2758.7kgf) 10240 lbf. (in 8-in. hole) (4646.2kgf)Sensors 7 balanced 3-coil arrays, spacings 6-94 in.Telemetry Standard GTS ModesCommand Mode 2 Tool Status Mode 2 Data Mappable: Modes 5 or 7 Calibration Environment 10 ft. off ground 30 ft. from metallic materials

www.RenheSun.comwww.geovista.cn

Four independent arm caliper meter, is the engineering logging and logging data borehole environment correction essential tool. Four arm are respectively connected with four in dependent potentiometer, and the relative two points series get a diameter data, achieve accurate measure of hole diameter functions.

Introduction

www.RenheSun.comwww.geovista.cn

ApplicationsMeasure the hole diameter

Four Arms Caliper-Slim Memory (FAC-SM)

SpecificationsMaximum Temperature 350°F (175°C)Maximum Pressure 20,000 psi (137.9 MPa)Tool Diameter 2.875 in. (73 mm)Minimum Hole Diameter 4 in. (101.6 mm)Maximum Hole Diameter 21 in. (533.4 mm)Make-up Length 11 ft.-1.98 in. (3.4 m)Shipping Length 12 ft.-6.43 in. (3.8 m)Weight 30.9 kgCaliper accuracy The accuracy of the diameter from 3.5 to 21 inches is 2%Working voltage: 36 VDC

m

The Battery Power Sub (BPS) contains up to battery packs inside. When ComboLog is fitted with a BPS, the working time is more than 50 hours.

Battery Power Sub (BPS)

Introduction

SpecificationsMaximum Temperature 350°F (175°C)Maximum Pressure 20,000 psi (137.9 MPa)Tool Diameter 2.875 in. (73 mm)Make-up Length 6 ft.-6.74 in. (2 m)Shipping Length 7 ft.-6.55 in. (2.3 m)Weight 50 kgOpen Circuit Voltage 36 VDCCapacity 26 A*h @ 500 mABattery Pack Type Lithium ChlorideMaximum Tensile Force 20,000 lbf.Maximum Compressive Force 78,000 lbf.

ApplicationsPower supply

www.RenheSun.comwww.geovista.cn

The Mass Isolator Sub-Slim (MIS-S) is designed as a substitute for long bridles on deep laterolog jobs.It has a standard 31-Pin connector and 9 feedthru wires. The pressure housing is comprised of a fiberglass substructure with an outer layer of rubber coating. The MIS-S should typically be located in the tool string below the cablehead.Two MIS-S are combined together to provide the necessary 24’ length of electrical isolation between the wireline armor of tool string housings, as required for the deep laterologs. The middle field joint of the assembled MIS-S’s serves as an SP sub and remote electrode.

Introduction

www.RenheSun.comwww.geovista.cn

Applications

Mass Isolator Sub-Slim (MIS-S)

SpecificationsMaximum Temperature 350°F (175°C)Maximum Pressure 20,000 psi (137.9 MPa)Tool Diameter 2.76 in.(70 mm)Make-up Length 12 ft.-8.64 in. (3.88 m)Shipping Length w/Thread Protectors 14 ft.-1.08 in. (4.29 m)Weight 62 lbs. (68.3 kg)Wire Requirements 7 conductor cableOperating Position AnyHole Deviation Vertical to HorizontalMaximum Borehole Curvature 10 degree/100 ft.Tensile Load Capacity 31,000 lbf.Compressive Load Capacity: 8 in. diameter borehole 9,500 lbf. 12 in. diameter borehole 6,000 lbf.Isolation >5 Meg Ohms – 500VDC (at rated temperature)

provide the necessary 24’ length of electrical isolation required by deep laterologs to separate the wireline armor from the logging tool string housings.

Used as an SP sub and remote electrode.

The ISS-S is designed to meet field demand for a high mechanical strength mass isolator to be used in conventional and pipe conveyed logging applications. The pressure housing is comprised of a metal substructure with an outer layer of fiberglass insulation material. Electrical mass isolation occurs in a specially designed bottom sub. The ISS-S should typically be located in the tool string upper the Dual Laterallog Tool-Slim Electronics and below the Micro Spherical Focused Laterolog Tool-Slim electronics.

Introduction

www.RenheSun.comwww.geovista.cn

Applications

Insulation Sub-Slim (ISS-S)

SpecificationsMaximum Temperature 350°F (175°C) Maximum Pressure 20,000 psi (137.9 MPa)Tool Diameter 2.75 in. (70 mm)Minimum Hole Diameter 3.5 in. (89 mm)Maximum Hole Diameter 12.0 in. (305 mm)Make-up length 1ft.-8.76 in. (0.53 m)Shipping length 3ft.-1.2 in. (0.95 m)Weight 30.42 lbs (13.8 kg) Tool Compressive Strength 50,000 lbf.Tool Tensile Strength 50,000 lbf.

Limit the length of the reflow electrode

The Swivel Assembly allows different portions of the tool string to rotate independently.It allows unrestricted 360°rotation by means of an internal slip-ring assemblyA swivel isolates an tool from the normal torque induced as the spiral-wound wireline is lowered into and pulled out of the well. This torque causes the tool string to rotatslowly-typically one or two rotations per 100 ft. (30) of depth for a seasoned line. Typically, this rotation does not cause any problems.

Introduction

www.RenheSun.comwww.geovista.cn

ApplicationsAvoid the tool rotation when the cable is rotating, and enhance the reliability.

Reduce the risk of cable head and tool string tripping when long tool strings connect.

Swivel Sub-Slim (SWS-S)

SpecificationsMaximum Temperature 430oF (220oC)Maximum Pressure 25,000 psi (172.4 MPa)Tool Diameter 2.75 in. (70 mm)Minimum Hole Diameter 3.5 in. (89 mm)Make-up length 4 ft.-2.64 in. (1.29 m)Shipping length 5 ft.-5.62 in. (1.67 m) Weight 59.3 lbs (26.9 kg)Number of Conductors 10Maximum Tensile Force 50,000 lbf.Maximum Compressive Force 50,000 lbf.

The FCS-S Centralizer is a 2.75" O.D., inline centralizer. The device is optional, but is intended to be run in conjunction with tools which require centralization in the borehole. The FCS-S consists of a central mandrel with integral upper tool joint, four Bow Spring Arms with replaceable wear plates, adjustable tension springs, and a Lower Sub.

Introduction

www.RenheSun.comwww.geovista.cn

ApplicationsUsed to conjunction with the tool which require centralization in the borehole

Four Arms Centralizer Sub-S (FCS-S)

SpecificationsMaximum Temperature 430oF (220oC)Maximum Pressure 25,000 psi (172.4 MPa)Tool Diameter 2.75 in. (70 mm)Minimum Hole Diameter 4 in. (101.6 mm)Maximum Hole Diameter 12 in. (304.8 mm)Make-up Length 5 ft-1.26 in. (1.56 m)Shipping Length 6 ft.-4.22 in. (1.94 m)Weight 55.2 lbss (25 kg)Maximum Tensile Force 50,000 lbf.Maximum Compressive Force 8,000 lbf.

Increased the tool strings bending flexibility in the high gradient well and horizontal well. Used between the center tool and the decenter tool.

Introduction

www.RenheSun.comwww.geovista.cn

Applications

Flex Joint Sub-Slim (FJS-S)

SpecificationsMaximum Temperature 430oF (220oC)Maximum Pressure 25,000 psi (172.4MPa)Tool Diameter 2.75 in. (70 mm) Minimum Hole Diameter 3.5 in. (89 mm)Maximum Deflection Angel 10°Make-up Length 4 ft.-0.23 in.(1.23 m)Shipping Length 5 ft.-3.19 in.(1.61 m)Weight 54.5 lbs (24.7 kg)Maximum Deflection Angel 10°Maximum Tensile Force 30,000 lbf.Maximum Compressive Force 5000 lbf.

Increased the tool strings bending flexibility in the high gradient well and horizontal well

Used between the center tool and the decenter tool

Introduction

www.RenheSun.comwww.geovista.cn

Applications

Decentralizer Sub-Slim (DCS-S)

SpecificationsMaximum Temperature 430oF (220oC) Maximum Pressure 25,000 psi (172.4 MPa)Tool Diameter 2.75 in. (70 mm)Minimum Hole Diameter 3.5 in. (89 mm)Maximum Hole Diameter 12.0 in. (305 mm)Make-up Length 6 ft.-10.08 in. ( 2.09 m)Shipping Length 8 ft.-1.05 in. (2.47 m)Weight 112.2 lbs (50.9 kg)Maximum Tensile Force 49,000 lbf.Maximum Compressive Force 44,500 lbf.

The DCS-S is 2.75”O.D ,inline decentralizer. The device is optional, but is intended to be run in conjunction with tool which require decentralization in the borehole.

Used to conjunction with the tools which require decentralization in the borehole

The Double Knuckle Joint -Slim is a compact universal ball joint with a limited degree of movement. It is used to add flexibility to the tool string.The device is optional.

IntroductionApplicationsprovide a nominal 10 angular off-set while the adjacent tool are positionaed against the bore hole wall

Double Knuckle Joint -Slim (DKJ-S)

SpecificationsMaximum Temperature 430°F (220°C)Maximum Pressure 25,000 psi (172.4 MPa)Weight 75 lbss (34 kg)Tool Diameter 2.76 in. (70 mm)Make-up Length 5 ft.- 1.42 in. (1.56 m)Shipping Length 6 ft.- 5.56 in. (1.97 m)Maximum Tensile Force 50,000 lbf.Maximum Compressive Force 20,000 lbf.Maximum Deflection Angel 10°Nominal per knuckle joint

www.RenheSun.comwww.geovista.cn

The Single Knuckle Joint -Slim is a compact universal ball joint with a limited degree of movement. It is used to add flexibility to the tool string. The device is optional.

IntroductionApplicationsprovide a nominal 10 angular off-set while the adjacent tool are positionaed against the bore hole wall

Single Knuckle Joint -Slim (SKJ-S)

SpecificationsMaximum Temperature 430°F (220°C)Maximum Pressure 25,000 psi (172.4 Mpa)Tool Diameter 2.75 in. (70 mm)Weight 50.7 lbs (23 kg)Make-up Length 3 ft.-1.63 in. (0.96 m)Shipping Length 4 ft.- 6.05 in. (1.37 m)Maximum Tensile Force 50,000 lbf.Maximum Compressive Force 20,000 lbf.Maximum Deflection Angel 10°Nominal per knuckle joint

www.RenheSun.comwww.geovista.cn

www.RenheSun.comwww.geovista.cn

ApplicationsUsed to conjunction with the tool which require pressure isolation in the borehole,prevent tool grouting

Pressure Isolation Sub (PIS)

SpecificationsMaximum Temperature 430°F (220°C)Maximum Pressure 25,000 psi (172.4 MPa)Tool Diameter 2.75 in. (70 mm)Minimum Hole Diameter 3.5 in. (89 mm)Maximum Hole Diameter 12.0 in. (305 mm)Weight 36.8 lbs. (16.7kg) Make-up length 1 ft.-10.68 in. (0.58 m)Shipping length 3 ft.-1.60 in. (0.96 m)Maximum Tensile Force 100,000 lbf.Maximum Compressive Force 100,000 lbf.

The Pressure Isolation Sub (PIS)is metal substructure with layer of fiberglass insulation meterial,it has few parts,is easy to assemble ,and is typically located in the upper and lower ends of the acoustic tool . this service is optional.

Introduction

Chief Operating Officer Wan HuiMobile:(+86) 13811697302 Tel :(+86) 010-89765689-807Email: [email protected] China Sales Supervisor Ding Litao Mobile:(+86) 13718369420 Email: dinglt@renhesun. com

China Sales ManagerDing Litao Mobile:(+86) 13718369420Email: [email protected]

Middle East Area ManagerWang Yuwen Mobile:(+86) 18910290806Email: [email protected]

International Sales Manager Sharry Liu Mobile:(+86) 13911317865 Email: [email protected]

International Sales Director Chen Gang Mobile:(+86) 13817367599 Email: chengang@renhesun. com

Middle East Operation Manager Zhen Shunli Mobile:(+86) 13683631587Email: [email protected]

China

Add: No. 1, Hua Chang Road, Science & Technology Park, Changping District, BeijingTel: (+86) 010-89765689-818 Zip:102200

Middle East

Russia

Add: No. 64, Novaya Street, Karmaskaly Town, Karmaskaly, Republic of Bashkortostan Tel: (+7) 9872578985 Zip:453020

South America

Add: University Avenue, between Traposos and Chorro streets, Centro Empresarial Building, tenth floor, Office number 10-C, Caracas. Tel: (+58) 04143200710

friendly cooperation

Marketing Manager Zhang Xujie Mobile:(+86) 13521254100Email: [email protected]

Product Manager Zhang Hong`ai Mobile:(+86) 18911632096Email: [email protected]

Russian Operation Manager Guo Feng Mobile:(+86) 13811796429 (+7) 917-3697194Email: guofeng@renhesun. com

Russian Technical Manager Chen Hua Mobile:(+86) 13811209770 (+7) 917-7358296Email: chenhua@renhesun. com

South America Technical Manager Gao Lijun Mobile:(+86) 15110265323 (+58) 4126944385Email: [email protected]