Page 1: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

1 1180582-W2-C

These instructions must be left with the user

Installation Guide

Skyline Quadrant Enclosure

Page 2: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

21180582-W2-C

Safety Information1. Careshouldbetakenwhendrillingintowallsandfloorstoavoidanyhiddenpipesor

wires.2. Westronglyrecommendthatallglasspanelsaremovedbyaminimumoftwopeople

andthatanyprotectivepackagingalongtheglassedgesiskeptinplaceforaslongaspossibletopreventdamagebeforeinstallation.

3. Duringinstallationwerecommendadditionalhelpinliftingheavydoorsandsidepanels.4. Wearprotectivefootwearwhenliftingpanels.5. Wear safety glasses when drilling.

Wall Preparation

GENERAL INFORMATION

The wa l l channe ls must be installed onto a tiled or waterproof finished flat andevenwallsurface.Failuretodoso will result in an unsatisfactory seal,whichmaycausepropertydamage.

INTRODUCTIONThankyouforpurchasingaqualityKOHLER®product.Toenjoythefullpotentialofyournewproduct,pleasetaketimetoreadthisguidethoroughly,havingdoneso,keepithandyforfuture reference.Thefollowingpagesaimtoprovidecomprehensiveinstallationinstructions,plusadviceonhowtocareandmaintainyourproduct.Werecommendthattheunitisinstalledbyaqualifiedplumberorengineer.

General1. Readalloftheseinstructionsandretainthisguideforlateruse.2. Passonthisguideintheeventofchangeofownershipoftheinstallationsite.3. Followallwarnings,cautionsandinstructionscontainedinthisguide.4. Removeallprotectivetapefromtheenclosurebeforeinstallation.

Page 3: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

3 1180582-W2-C

6.0 mm

2.0 mm 3.0 mm

TOOLS REQUIRED

GUARANTEEFordomestic installations,yourenclosurehasthebenefitofourlifetimeguaranteewhichstartsfromdateofpurchase.

Fornon-domestic installations,weguaranteetheproductagainstanydefectinmaterialsorworkmanshipforaperiodofoneyearfromthedateofpurchase.

Fortermsandconditionsrefertothebackcoverofthisguide.

RecommendedUsageDomestic ü

LightCommercial ü

HeavyCommercial û

Healthcare û

Page 4: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

41180582-W2-C

x 1

x 2

x 1

PACK CONTENTS

x 6

x 6

x 2

1 x 3.0 mm A/F

x 2

1 x 2.0 mm A/F

x 8

x 4

x 4

x 4

x 4

x 1

Page 5: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

5 1180582-W2-C

X 2 qX 2 q

X 2 q

X 2 qX 2 q

X 1 q

Pack 1

X 2 q

Page 6: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

61180582-W2-C

X 2 qX 2 q

Pack 2

Page 7: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

7 1180582-W2-C

INSTALLATION

Note!Coverthetraywastetopreventthelossofsmallparts. Note! Protect the tray surface during enclosure installation.

1

Note! Make sure that the wallshavebeentileddownto the tray.

Height of Enclosure (mm) 1900

Min/Max Frame Adjustment Enclosure Size Minimum (mm) Maximum (mm)800 768 798

900 868 898

1000 968 998

1200 1168 1198

(a) Install the shower tray in accordance with the manufacturer’s instructions. Caution!Makesurethattheshowertrayislevelandthatthewallsarevertical

andsquare.

± 0 mm

8 mm

a

b

c

Page 8: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

81180582-W2-C

2

(a) Removethewallchannel.

Page 9: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

9 1180582-W2-C

3

(a) Positionthewallchannelonthewall.Usingaspiritlevelmakesurethatitisupright.

(b) Markthepositionofthefixingholes,thenremovethewallchannel.(c) Drillwitha6mmmasonrybit (notsupplied)andplugusing thewallplugs

(supplied).

8 mm

± 0 mm

6 mm

x3

x3

x3

a

b

c

Page 10: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

101180582-W2-C

4

(a) Positionthesecondwallchannelonthewall.Usingaspiritlevelmakesurethatitisupright.

(b) Markthepositionofthefixingholes,thenremovethewallchannel.(c) Drillwitha6mmmasonrybit (notsupplied)andplugusing thewallplugs

(supplied).(d) Positionthewallchannelonthewallandinstallthefixingscrews.(e) Fullytightenthefixingscrews,makingsurethatthewallchannelisupright.

8 mm

± 0 mm

6 mm

x3

x3

x3

a

d

c

b

Page 11: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

11 1180582-W2-C

5

b

a+ 5 mm

bH

2 O

(a) Cutthesealtolengthandfitontotheglass.(b) Fittheglassintothebottomtrackmakingsurethattheseallocatescorrectly.

Page 12: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

121180582-W2-C

6

(a) Fittheplasticretainersandinstallthescrewstosecurethetheassembly.

Page 13: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

13 1180582-W2-C

57

(a) Cutthesealtolengthandfittothetopoftheglass.(b) Fitthetoptrackovertheglassandsealmakingsuretheseallocatescorrectly.1

+ 5 mm

1

+ 5 mm

a

a

b

c

H2 O

H2O

Page 14: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

141180582-W2-C

8

(a) Fittheplasticretainersandinstallthescrewstosecurethetheassembly.

Page 15: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

15 1180582-W2-C

9

x3

a

b

(a) Installthefirstwallchannelintothedoorframeandholdinposition.(b) Installthedoorframeoverthewallchannelthathadbeensecuredtothewall

earlier.(c) Adjustthedoorframesothatitisinthecorrectposition.(d) Installthewallchannelfixingscrewsthroughtheaccessholesinthedoorframe.(e) Fullytightenthefixingscrews,makingsurethatthewallchannelisupright.

X3

Page 16: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

161180582-W2-C

90° 90°

± 0 mm± 0 mm

x3

510

3.0 mm

(a) Usingthe3.0mmhexagonalwrench(supplied),turnthrough90°tolockthedoorframeinposition.

Page 17: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

17 1180582-W2-C

90° 90°

± 0 mm± 0 mm

x3

511

3.0 mm

(a) Usingthe3.0mmhexagonalwrench(supplied),turnthrough90°tolockthedoorframeinposition.

Page 18: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

181180582-W2-C

(a) Install the seals to the glass.

512

SideProfile

Page 19: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

19 1180582-W2-C

513

(a) Installtheflexibletrackinfillstriptothetopandbottomtracks.

Page 20: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

201180582-W2-C

514

12

a

c

b

(a) Installtheinfillstripsasshownabove.

Page 21: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

21 1180582-W2-C

515

a

c

b

d

(a) Turn the door so that it in the correct orientation.(b) Fullyturntheallenkeyclockwiseonbothtoprollerstolockrollersinuppermost

position.(c) Refitthedoorbyfirstlocatingthetoprollerassembliesonthetrack.(d) Fittherollercovers.

Page 22: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

221180582-W2-C

516

Ifthedoorisoutofsquare,adjustasfollows:(a) Unlocktherollerassemblies(b) Adjustthedoorasrequired.(c) Locktherollerassemblies.(d) Fitthechromecovers.

a

b

c d

Page 23: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

23 1180582-W2-C

a

c

b

d

517

(a) Unlockthebottomrollerassemblies.(b) Movethebottomrollerassembliesupordownuntiltheylocatecorrectlyinthe

bottom track and release correctly using the roller release buttons.(c) Lockthebottomrollerassemblies.(d) Fitthechromecovers.

Page 24: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

241180582-W2-C

518

90010001200

90010001200

800 800

(a) Fitthesealstothesideofthedoors.(b) Fitthemagneticsealstothedoorsmakingsuetheylockcorrectly.

Page 25: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

25 1180582-W2-C

x 1

x 2

x 1

2.0 mm

519 520

521

Page 26: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

261180582-W2-C

522

==

(a) Fittherubberdoorstoptothetopandbottomtracks,makingsureitiscentrallylocated.

Page 27: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

27 1180582-W2-C

(a) Applysealantinaccordancewiththesealantmanufacturersinstructionsalongthe outside surfaces of the door frame only.

(b) Allow the silicone sealant to cure for 24 hours before use.(c) Fittheplasticcoverstothetopoftheextrusions.

ab

23

Page 28: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

281180582-W2-C

MAINTENANCEGeneral MaintenanceProviding the shower enclosure hasbeen correctly installed and is operated inaccordancewiththeinstructionscontainedinthisguide,difficultiesshouldnotarise.

Ifanymaintenanceisrequiredthenitmustbecarriedoutbyacompetenttradespersontowhomthemaintenanceinstructionsareprovided.

Beforereplacinganypartsensuretheunderlyingcauseofthemalfunctionhasbeenresolved.

CleaningWarning!Manyhouseholdcleanerscontainabrasiveandchemicalsubstancesandshouldnotbeusedforcleaningpainted,platedorplasticfittings.Thesefinishesshouldbecleanedwithamildwashingupdetergentorsoapsolutionandthenwipeddryusingasoftcloth.

CareTopreservethebeautyofyourshowerenclosureformanyyears,pleaseobservethefollowingcareinstructions:

Rinseglassand framewithclearwateraftershowering.Removewaterdropletswithasqueegee.Donotrubdry!Tocleanyourshowerhygienicallyandeasily,werecommend the use of a biodegradable cleanser.

Regular cleansingwith a biodegradable cleanser prevents stubborn stains andensures a clean and hygienic surface for many years. Do not use scouring or caustic cleansersunderanycircumstances!Thesecandamagethesurfaceoftheframe,glassanddecorativepartsaswellastheplasticparts.

Chrome PartsUseonlycleansersexpresslyspecifiedforchrome!

Page 29: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

29 1180582-W2-C

SPARE PARTS

Page 30: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

301180582-W2-C

SPARE PARTS

1 1781.376 HandleSpare

2 1781.419 SliderTopBearingSpare

3 1781.420 SliderBottomBearingSpare

4 1781.380 LockingMechanismSpare

5 1781.381 InfillSpare

6 1781.511 Quad Seal Pack

7 1781.500 800PanelSpare

1781.501 900PanelSpare

1781.502 1000PanelSpare

1781.503 1200PanelSpare

8 1781.377 DoorTopCapSpares

9 1781.499 QuadrantDoorSpare

Page 31: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

31 1180582-W2-C

1

5

6

4

4

4

4

4

4

2 2

2

6

3 33

5

6 6

6

7 7

9 9

88

Page 32: Skyline Quadrant Enclosure - KOHLER€¦ · Skyline Quadrant Enclosure. 1180582-W2-C 2 Safety Information 1. Care should be taken when drilling into walls and floorsto avoid any hidden

321180582-W2-C ©KohlerCo.March2013

0044 844 571 0048

Kohler Mira LimitedCustomer Services Dept,1 Penrose Place,Skelmersdale,WN8 9PR

To Contact Us: UK

Fax: 0044 844 571 7157

CUSTOMER SERVICE

E-mail: [email protected]

To Contact Us: Eire Only

0844 571 0048

Fax: 0844 571 7157

Helpdesk ServiceOur Customer Services Team is comprehensively trained and can offer help and advice, spare parts, accessories or a service visit.

We will need you to have your model name, model number and date of purchase.

KOHLER® Website (www.KOHLER.co.uk)From our website you can download additional user guides or request a service visit.

Spares and AccessoriesWe hold the largest stocks of genuine Kohler spares and accessories.Contact us for a price and to purchase spares or accessories.

Service / RepairsNo one knows our products better than our nationwide team of Service Technicians. We can carry out service or repair work to your product both during and after the guarantee period.

Ask about our fi xed price service repairs.

GuaranteeYour enclosure has the benefi t of our lifetime guarantee which starts from the date of purchase.To activate this guarantee, you must return your completed registration card with a copy of proof of purchase from an approved Kohler retailer within 30 days of purchase.This guarantee is in addition to your statutory rights and is subject to conditions (see registration card).

What to do if something goes wrongIf your product does not function correctly when you fi rst use it, contact your installer to check that it is installed in accordance with the instructions in this manual.

If this does not resolve the issue, contact our Customer Services Team who will offer you or your installer help and advice.

Kohler Mira Limited, Cromwell Road, Cheltenham,Gloucestershire, GL52 5EP, UK

13EN 14428:2004 + A1: 2008

By Post:

Kohler is a registered trade mark.The company reserves the right to alter product specifi cations without notice.

(298)